Installation Instructions 36" Glass Canopy Chimney Vent Hood

Installation Instructions 36" Glass Canopy Chimney Vent Hood

Installation

Instructions

36" Glass Canopy

Chimney Vent Hood

ZV900

49-80328-3

Safety Information

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT

³

Save these instructions for local inspector’s use.

IMPORTANT

³

Observe all governing codes and ordinances.

Note to Installer

³

Be sure to leave these instructions with the Consumer.

Note to Consumer

³

Keep these instructions with your Owner’s Manual for future reference.

Skill Level

³

Installation of this appliance requires basic mechanical and electrical skills.

Completion Time

³WR+RXUV

• Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the warranty.

For Monogram local service in your area, call

)RU0RQRJUDPVHUYLFHLQ&DQDGDFDOO

For Monogram Parts and Accessories, call

CAUTION:

Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product,

TWO PEOPLE ARE REQUIRED FOR PROPER

INSTALLATION.

PRUDENCE :

À cause du poids et de la taille de ces hottes et pour reduire le risque de blessures et de dommages,

IL

FAUT DEUX PERSONNES POUR FAIRE L’INSTALLATION

CORRECTEMENT.

WARNING:

To reduce the risk of fire or electrical shock, do not use this range hood with any external solid-state speed control device. Any such alteration from original factory wiring could result in damage to the unit and/or create an electrical safety hazard.

AVERTISSEMENT :

Pour réduire le risque d’incendie ou de choc électrique, il ne faut pas utiliser cette hotte avec un régulateur de vitesse électronique externe. Toute modification de ce type du branchement d’usine peute endommager l’appareil ou créer un risque de choc électrique.

TO REDUCE THE RISK OF FIRE, USE ONLY METAL

DUCTWORK.

2

WARNING:

TO REDUCE THE RISK OF

FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING:

A.

Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

B.

Before servicing or cleaning unit, switch power off at the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel.

AVERTISSEMENT :

POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC

ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES

REGLES SUIVANTES :

A.

Utiliser cet appareil uniquement de la maniére prévue par le fabricant. En cas de question, consulter le fabricant.

B.

Avant toute intervention ou nettoyage, couper l’alimentation électrique au disjoncteur et verrouiller le panneau du disjoncteur pour éviter la mise sous tension accidentelle. S’il n’est pas possible de verrouiller le panneau du disconcteur, attacher un placard ou une étiquette trés visible au panneau.

• For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors.

• Structural framing, installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards including fire-rated construction.

• Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the

National Fire Protection Association (NFPA), and the

American Society for Heating, Refrigeration and Air

Conditioning Engineers (ASHRAE), and the local code authorities. When applicable, install any makeup

(replacement) air system in accordance with local building code requirements. Visit

GEAppliances.com

for available makeup air solutions.

• Local codes vary. Installation of electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should be installed in accordance with National

Electrical Code ANSI/NFPA 70-1990 or latest edition.

CAUTION:

To reduce risk of fire and to

SURSHUO\H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH³GRQRW vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.

PRUDENCE :

Il faut prendre soin d’installer un conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement.

Il ne faut pas évacuer l’air correctement. Il ne faut pas

évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage.

Design Information

CONTENTS

Design Information

Product Dimensions and Clearances ....................................................3

Installation Options ........................................................................................3

Installation Preparation

Advance Planning, Ductwork, Framing ................................................4

Power Supply ....................................................................................................4

Duct Fittings .......................................................................................................5

Tools and Materials Required ....................................................................6

Remove the Packaging.................................................................................6

Determine Installation Height ...................................................................7

Wall Mount Installation Heights ...............................................................7

Check Installation Hardware .....................................................................8

,QVWDOODWLRQ³9HQWHGWRWKH2XWVLGH

Ductwork, Wiring Locations .......................................................................9

Step 1, Install Framing for Hood Support ............................................9

Step 2, Install Mounting Bracket ........................................................... 10

Step 3, Install Duct Bracket ..................................................................... 10

Step 4, Prepare the Hood ......................................................................... 11

Step 5, Mount the Hood ............................................................................ 12

Step 6, Level the Hood ............................................................................... 12

Step 7, Connect Ductwork ....................................................................... 12

Step 8, Connect Electrical ......................................................................... 13

Step 9, Install Duct Covers ....................................................................... 14

Step 10, Install Filters.................................................................................. 14

Step 11, Finalize Installation ................................................................... 14

,QVWDOODWLRQ³5HFLUFXODWLQJ

Ductwork, Wiring Locations .................................................................... 15

Step 1, Install Framing for Hood Support .........................................15

Step 2, Install Mounting Bracket ........................................................... 16

Step 3, Install Duct Bracket ..................................................................... 16

Step 4, Prepare the Hood ......................................................................... 17

Step 5, Mount the Hood ............................................................................ 17

Step 6, Level the Hood ............................................................................... 17

Step 7, Size and Cut Duct Piece ............................................................ 18

Step 8, Connect Electrical ......................................................................... 18

Step 9, Install Duct Covers ....................................................................... 19

Step 10, Install Filters.................................................................................. 19

Step 11, Finalize Installation ................................................................... 19

PRODUCT DIMENSIONS

AND CLEARANCES

INSTALLATION OPTIONS

*Height to

Ceiling

24” Min.

30” Max.

* The Supplied Duct Cover Fits 8' to 9'-5" Ceiling

Heights. For 9'-6" to 10'-5" ceilings, order ZX90010.

7KHYHQWKRRGPXVWEHLQVWDOOHGPLQDQG

d

max. above the cooking surface. The hood installation height above the cooking surface depends upon ceiling height.

The telescopic duct cover conceals the ductwork running from the top of the hood to the ceiling.

7KHVXSSOLHGGXFWFRYHULVVL]HGWRUHDFKWR

ceiling heights.

7KH=;DFFHVVRU\LVDYDLODEOHIRUFHLOLQJ

KHLJKWVRIWR

3

NOTE:

Installation height should be measured from the cooking surface to the outer glass sides.

This hood may be installed onto a wall and vented to the outdoors, or it can be installed for recirculating operation. All necessary parts for recirculating operation are supplied with th e hood. No kits required.

This hood can be installed over any Monogram electric cooktop or gas cooktop. It cannot be installed over a Monogram Professional cooktop or range.

Installation Preparation

ADVANCE PLANNING

• Determine the exact location of the vent hood.

• Plan the route for venting exhaust to the outdoors.

• Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 ft. equivalent length for any duct configurations.

• Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors.

• When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit

GEAppliances.com

for available makeup air solutions.

CAUTION:

To reduce risk of fire and to properly

H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH³GRQRWYHQWH[KDXVW air into spaces within walls or ceilings or into attics, crawl spaces or garages.

PRUDENCE :

Il faut prendre soin d’installer un conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage.

POWER SUPPLY

IMPORTANT – (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS

APPLIANCE MUST BE PROPERLY GROUNDED.

AVERTISSEMENT :

POUR DES RAISONS DE

SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MISE

À LA TERRE.

Remove house fuse or open circuit breaker before beginning installation.

Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.

Electrical supply

These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.

• Wiring must be 2 wire with ground.

• If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.

• Route house wiring as close to the installation location as possible, in the ceiling or back wall.

• Connect the hood wiring to the house wiring in accordance with local codes.

4

• Use metal ductwork only. These hoods must use

8" round duct.

• Install a wall cap with damper or roof cap at the exterior opening. Order the wall or roof cap and any transition needed in advance.

Wall Framing for Adequate Support

• This vent hood is heavy. Adequate structural support must be provided in all types of installations. The hood must be secured to vertical studs in the wall, or to a horizontal support.

• The vent hood should be on site before final framing and wall finishing. This will help to accurately locate the duct work and electrical service.

• Installation will be easier if the vent hood is installed before the cooktop and countertop are installed.

Accessory Duct Cover

• This hood is shipped with a decorative duct cover for ceiling heights of 7’-11" to 9'-5". ZX90010 duct cover accessory is available to reach 9'-6" to 10'-5" ceiling heights. The accessory should be ordered with the hood and be on site before installation begins.

Grounding instructions

The grounding conductor must be connected to a grounded metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.

WARNING:

The improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.

AVERTISSEMENT :

Le mauvais branchement du fil de mise à la terre peut causer un choc

électrique. En cas de doute, consulter un électricien qualifié ou un technicien pour déterminer si l’appareil est à la terre.

CAUTION:

Automatically Operated Device –

To reduce the risk of injury disconnect from power supply before servicing. This unit is equipped with an integral disconnecting switch located inside the blower housing.

PRUDENCE :

Appareil commandé automatiquement. Afin de réduire les risques de blessure, débranchez l’appareil de l’alimentation électrique avant de procéder à une réparation. L’appareil est équipé d’un sectionneur intégral situé à l’intérieur du logement du ventilateur.

Installation Preparation

DUCT FITTINGS

This Hood Must Use an

d

Round Duct. It Can

Transition to a

d

[

d

Duct.

Use this chart to compute maximum permissible lengths for duct runs to outdoors.

NOTE:

Do not exceed maximum permissible equivalent lengths!

Maximum duct length:

IRRWIRUUDQJHKRRGV

Flexible ducting:

If flexible metal ducting is used, all the equivalent feet values in the table should be doubled.

The flexible metal duct should be straight and smooth and extended as much as possible.

DO NOT use flexible plastic ducting.

NOTE:

Any home ventilation system, such as a ventilation hood, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems.

To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE

.

When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit

GEAppliances.com

for available makeup air solutions.

Duct Piece Dimensions

Round,

straight

Equivalent

Length*

foot length)

3-1/4" x 12"

straight elbow elbow

1 ft.

(per length)

ø[

90° elbow

3-1/4" x 12"

45° elbow

3-1/4"

90° flat elbow

43 ft.

26 ft.

102 ft.

2 ft.

8" round to

3-1/4" x 12" transition

3-1/4" x 12" to 8" round transition

8" to 3-1/4" x 12" transition 90° elbow

5 ft.

6 ft.

Total

Quantity

Used Length

3-1/4" x 12" to 8" round transition 90° elbow 13 ft.

Round cap with damper

3-1/4” x 12" wall cap with damper

Round roof cap

32 ft.

75 ft.

44 ft.

* Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation

Engineering and reflect requirements for good venting performance with any ventilation hood.

Total Duct Run

5

Installation Preparation

TOOLS AND MATERIALS REQUIRED

(NOT SUPPLIED

)

“

Tape measure

“

Knife

“

Spirit level

“

Wire cutter/stripper

“

Wire nuts

“

Electric drill with 5/16" and 3/8" bits

“

Phillips and flat blade screwdrivers

“

Hammer

“

Pliers

“

Safety glasses

“

Duct tape

“

Tape to mount template

Measuring tape

Pliers

“

Gloves to protect against sharp edges

“

120V 60Hz. 15 or 20 Amp, 2 wire with ground Properly grounded branch circuit

“

Strain relief for junction cover

“

8" round metal duct, length to suit installation

“

Saw, jig saw or reciprocating saw

Duct tape

Strain relief

12” long

Phillips head screwdriver

Spirit level

Electric drill with 5/16” and 3/8” Bits

Safety glasses

Wire nuts

Gloves

Knife

Wire cutter/ stripper

Hammer

Flat blade screwdriver

Masking tape

Saw, jig saw or reciprocating saw

8" round metal duct, length to suit installation

REMOVE THE PACKAGING

CAUTION:

LIFT THE HOOD OUT OF THE BOX

BY THE CENTER METAL PORTION. DO NOT LIFT BY THE

GLASS SIDES.

PRUDENCE :

LEVEZ LA HOTTE À

L’EXTÉRIEUR DE LA BOÎTE PAR LA PORTION MÉTAL

CENTRAL. NE LEVEZ PAS PAR LES CÔTÉS DE VERRE.

CAUTION:

Wear gloves to protect against sharp edges.

PRUDENCE :

Portez des gants pour éviter les blessures causées par les tranchants.

• Grasp the hood by the metal insert in the center and lift straight up and out of the box.

• Remove and properly discard the plastic wrapping.

• Remove parts box, duct covers and other packaging.

6

DETERMINE INSTALLATION HEIGHT

• Telescopic duct covers are provided to conceal the ductwork running to the ceiling.

• This hood can be installed for recirculating operation. No kits required.

NOTE:

Measure installation height from the cooking surface to the outer glass portion of the hood.

Installation Preparation

24” Min.

30” Max.

36” Min.

The vent hood must be installed 24" min. and

30" max. above the cooking surface. The hood installation height, from the cooking surface to the bottom of the hood, depends upon ceiling height.

ACCESSORIES

:

• Order ZX90010 accessory for ZV900 wall mount hood to reach ceiling heights between 9'-6" and

10'-5". This accessory contains one 40" long duct cover.

7'-11"

8'-0"

8'-1"

8'-2"

8'-3"

8'-4"

8'-5"

8'-6"

8'-7"

8'-8"

8'-9"

8'-10"

8'-11"

9'-0"

9'-1"

9'-2"

9'-3"

9'-4"

9'-5"

9'-6"

9'-7"

9'-8"

9'-9"

9"-10"

28" to 30"

29" to 30"

30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

9'-11"

10'

10'-1"

10'-2"

24" to 30"

24" to 30"

24" to 30"

25" to 30"

10'-3"

10'-4"

26" to 30"

27" to 30"

10'-5" 28" to 30"

*Based on 36 d

countertop height.

24" to 26"

24" to 27"

24" to 28"

24" to 29"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

25" to 30"

26" to 30"

27" to 30"

:DOO0RXQW=9

Installation Heights

Actual

Ceiling *Possible

Height

*Possible

VENTED RECIRCULATING

Installation Height Installation Height

24" to 30"

24" to 30"

25" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

25" to 30"

26" to 30"

27" to 30"

24" to 26"

24" to 27"

24" to 28"

24" to 29"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

24" to 30"

25" to 30"

26" to 30"

24" to 30"

24" to 30"

24" to 30"

7

Installation Preparation

CHECK INSTALLATION HARDWARE

Locate the hardware accessory box packed with the hood and check contents.

HARDWARE PACKAGE

Locate and count screws

Air deflector for recirculating installation only

Duct bracket

3 wood screws

3 wall fasteners

3 wall bracket screws

2 thumb screws

12 hood attachment screws

Drill 2 (two) 3/16≤ pilot holes through studs or rear wall support

14-5/8≤ to top of bracket

C

L

REAR WALL

MOUNTING TEMPLA TE

49-80405 04-06 JR

ALIGN BOTT OM EDGE

WITH PENCIL LINE,

INDICA TING BOTT OM

OF THE HOOD t

Wall mount template

1 charcoal filter for recirculating installation

2-piece decorative duct cover (dimension shown for reference only)

Stainless steel filter

Mounting bracket

8

Installation Instructions

,167$//$7,21³9(17('727+(2876,'(

DUCTWORK, WIRING LOCATIONS

Determine the exact location of the vent hood.

• Locate the template packed with the literature.

– Measure 36" from the floor to the top of the cooking surface. Add hood installation height determined on page 7. Mark that location.

– Use a level to draw a straight pencil line on the wall.

5-1/2” c enterline to wall FOR CEILING VENT DUCTING

8-1/2” dia. hole

FOR WALL VENT DUCT

Ceiling

Centerline 26” above the marked bottom pencil line for installation height.

INSTALL FRAMING FOR HOOD

SUPPORT

IMPORTANT

³

Framing must be capable of supporting 100 lbs.

8-1/2” min. opening for ductwork

View from rear cleats

1” x 6” min. mounting support

Centerline of installation space

– Tape the template in position along the penciled line. CHECK TO BE SURE THE TEMPLATE IS LEVEL.

Ceiling ducting:

If ductwork will vent straight up to the ceiling:

• Use a level to draw a line straight up, from the centerline on the template to the ceiling.

• Measure 5-1/2" from the back wall to the centerline of an 8-1/2" hole on the ceiling.

NOTE:

If drywall is not present, add drywall thickness to the 5-1/2" dimension.

Wall Ducting:

If ductwork will vent to the rear:

• Use a level to draw a line straight up from the centerline on the template.

• Measure at least 26" above the pencil line that indicates the bottom installation height, to the centerline of an 8-1/2" dia. duct hole. (Hole may be elongated for duct elbow.)

HOUSE WIRING LOCATION:

• The junction box is located on the top left side of the hood.

• Wiring should enter the back wall at least 22" above the bottom of the hood, and within 6" of the left side of the centerline.

9

If drywall is present, mark the screw hole locations for the top mounting brackets. Remove the template.

• Cut away enough drywall to expose 2 vertical studs at the bracket location indicated on the template.

• Install a horizontal support at least 1" x 6" between two wall studs at the bottom mounting bracket installation location.

The horizontal support must be flush with the room side of the studs.

Use cleats behind both sides of the support to secure to wall studs.

• Reinstall drywall.

Installation Instructions

,167$//$7,21³9(17('727+(2876,'(

INSTALL MOUNTING BRACKET

This vent hood must be secured to the horizontal support or wall studs.

• With the template taped in place, use a punch to mark mounting bracket screw locations.

• Drill 3/16" pilot holes in 2 of the punched locations in the lower bracket.

• Remove the template.

Drill 2 (two) 3/16≤ pilot holes through studs or rear wall support

14-5/8≤ to top of bracket

REAR WALL

MOUNTING TEMPLA TE

3 INSTALL DUCT BRACKET

The duct bracket should be installed against the back wall and flush with the ceiling. This bracket will hold the duct cover in place at the top.

Secure the bracket to the wall:

• Align the marked centerline on the bracket with the centerline on the wall.

• Mark 2 screw hole locations in the wall.

• Drill 3/16" pilot holes in the marked locations.

• If pilot holes do not enter studs, enlarge the holes to 3/8" and install wall fastener anchors.

• Drive screws, by hand, into the fasteners to allow anchors to expand. Remove the screws.

• Secure the bracket to the wall with wood screws and/or fasteners.

49-80405 04-06 JR

ALIGN BOTT OM EDGE

WITH PENCIL LINE,

INDICA TING BOTT OM

OF THE HOOD t

• Use wood screws to secure the mounting bracket to the wall. The screws must engage wall studs or the installed horizontal mounting support.

• Check to be sure that the bracket is level.

10

Installation Instructions

,167$//$7,21³9(17('727+(2876,'(

PREPARE THE HOOD

• Place the hood on a padded surface.

• Position the motor housing at the back of the hood.

Electrical connectors should face the front, with rear mounting hooks at the back.

• Slip the bottom flange of the motor housing into the side slots at the top rear opening.

• Carefully lay the hood on its back.

• Fasten the hood to the motor housing from the bottom, using 6 screws.

Front side

Bottom view

Rear mounting hooks

Rear side

• Join two cable connectors at the front of the hood.

Rear view

Engage flange on motor housing into slots

To Lights

To

Control

Panel

11

Installation Instructions

,167$//$7,21³9(17('727+(2876,'(

MOUNT THE HOOD

WARNING:

2 people are required to lift and position the hood onto the mounting bracket.

AVERTISSEMENT :

If faut deux personnes pour lever et mettre en place la hotte sur le support de montage.

• Lift the hood onto the mounting bracket.

• Position a spirit level at the bottom of the hood to check side to side leveling.

7 CONNECT DUCTWORK

• Install ductwork, making connections in the direction of airflow as illustrated.

• Push duct over the exhaust outlet and damper.

• Secure joints in ductwork with sheetmetal screws.

• Wrap all duct joints and the flange connections with duct tape for an airtight seal.

Airflow

6 LEVEL THE HOOD

This hood has built-in levelers on the mounting hooks at each side. Use a long Phillips screwdriver from the front to access the levelers.

Duct tape over seam and screw

Screw

Levelers

CAUTION:

Do not use sheet metal screws at the hood flange connection. Doing so will prevent proper damper operation. Seal connection with tape only.

PRUDENCE :

Il ne faut pas utiliser de vis autoraurdeuses à la connexion du collet de la hotte. Ceci empêcherait le bon fonctionnement du registre. N’utiliser que du ruban adhésif pour assurer l’étanchéité du raccord.

• Use the top screw hole in the leveler to raise or lower the hood on that side.

• Use the bottom screw hole to pull the hood tight against the wall surface.

Screw hole

• Mark hole location at the bottom of the hood.

• Remove the hood. If the bottom screw hole does not enter a stud, enlarge the hole to 3/8 d

and install wall fastener anchors.

• Place the hood back onto the mounting bracket, check level again and install the wall fastener.

12

Installation Instructions

,167$//$7,21³9(17('727+(2876,'(

CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.

AVERTISSEMENT :

Si la maison n’est pas câblee avec deux fils et un fil de terre, l’installateur doit installer un fil de terre.

Quand les fils sont en aluminium, il faut prendre soin d’utiliser des connecteurs aluminium à cuivre avec une pâte antioxydante approuvée par U.L.

• Remove junction box cover and knockout on the left side.

Knockout

• Secure the house wiring to the junction box with a strain relief.

House wiring

13

• Connect white leads to branch circuit white lead.

• Connect black leads to branch circuit black lead.

• Connect green/yellow leads to branch circuit green lead or bare ground lead.

• Secure all connections with wire nuts on each electrical connector.

• Push wires into junction box and replace cover.

Be sure wires are not pinched.

• Secure J-Box cover with original screw.

Installation Instructions

,167$//$7,21³9(17('727+(2876,'(

INSTALL DUCT COVERS

• Place the decorative duct covers on top of the hood.

NOTE: The inside (upper) duct piece has holes on one end. The holes are intended for use when the hood is

Mounting screws installed for recirculating purposes. Slide the inside end into the outer piece; the vent holes should not be visible in this installation.

The inside duct piece must slip into the folded ends of the outer section.

Duct cover support bracket

INSTALL FILTERS

IMPORTANT:

Check to be sure that the main ON/

OFF switch next to the motor is in the ON position.

• Remove protective film on the filters.

Filter Lock

NOTE:

The charcoal filter is not required for this installation.

• Tip the filter into the left or right side of the opening. Lift the filter to the opposite side and into the filter lock.

• To remove the filter, pull the filter lock downward.

Upper duct cover

Lower duct cover

Duct cover support bracket

FINALIZE INSTALLATION

• Check to be sure all tape and packaging materials have been removed.

• Refer to the Owner’s Manual for operating instructions.

Lower duct cover seat

• Extend the inner duct upward to the ceiling bracket.

• Secure duct cover to ceiling bracket with 2 screws.

14

Installation Instructions

,167$//$7,21³5(&,5&8/$7,1*

DUCTWORK, WIRING LOCATIONS

• Determine the exact location of the vent hood.

• Locate the template packed with the literature.

• Measure 36 d

from the floor to the top of the cooking surface. Add hood installation height determined on

page 7. Mark that location.

1

INSTALL FRAMING FOR HOOD

SUPPORT

IMPORTANT:

Framing must be capable of

VXSSRUWLQJOEV

Ceiling

View from rear cleats

1” x 6” min. mounting support

• Tape the template in position along the penciled line.

CHECK TO BE SURE THE TEMPLATE IS LEVEL.

• Use a level to draw a line straight up, from the centerline on the template to the ceiling.

HOUSE WIRING LOCATION:

• The junction box is located on the top left side of the hood.

• Wiring should enter the back wall at least 22 d above the bottom of the hood, and within 6 d of the centerline.

Centerline of installation space

If drywall is present, mark the screw hole locations for the top mounting brackets. Remove the template.

• Cut away enough drywall to expose 2 vertical studs at the bracket location indicated on the template.

• Install a horizontal support at least 1" x 6" between two wall studs at the bottom mounting bracket installation location.

The horizontal support must be flush with the room side of the studs.

Use cleats behind both sides of the support to secure to wall studs.

• Reinstall drywall.

15

Installation Instructions

,167$//$7,21³5(&,5&8/$7,1*

INSTALL MOUNTING BRACKET

This vent hood must be secured to the horizontal support or wall studs.

• With the template taped in place, use a punch to mark mounting bracket screw locations.

• Drill 3/16" pilot holes in 2 of the punched locations in the lower bracket.

• Remove the template.

Drill 2 (two) 3/16≤ pilot holes through studs or rear wall support

14-5/8≤ to top of bracket

C

L

REAR WALL

MOUNTING TEMPLA TE

3 INSTALL DUCT BRACKET

The duct bracket should be installed against the back wall and flush with the ceiling. This bracket will hold the duct cover in place at the top.

Secure the bracket to the wall:

• Align the marked centerline on the bracket with the centerline on the wall.

• Mark 2 screw hole locations in the wall.

• Drill 3/16 d

pilot holes in the marked locations.

• If pilot holes do not enter studs, enlarge the holes to 3/8 d

and install wall fastener anchors.

• Drive screws, by hand, into the fasteners to allow anchors to expand. Remove the screws.

• Secure the bracket to the wall with wood screws and/or fasteners.

49-80405 04-06 JR

ALIGN BOTT OM EDGE

WITH PENCIL LINE,

INDICA TING BOTT OM

OF THE HOOD t

• Use wood screws to secure the mounting bracket to the wall. The screws must engage wall studs or the installed horizontal mounting support.

• Check to be sure that the bracket is level.

16

Installation Instructions

,167$//$7,21³5(&,5&8/$7,1*

PREPARE THE HOOD

• Place the hood on a padded surface.

• Position the motor housing at the back of the hood.

Electrical connectors should face the front, with rear mounting hooks at the back.

• Slip the bottom flange of the motor housing into the side slots at the top rear opening.

MOUNT THE HOOD

WARNING:

2 people are required to lift and position the hood onto the mounting bracket.

AVERTISSEMENT :

If faut deux personnes pour lever et mettre en place la hotte sur le support de montage.

• Lift the hood onto the mounting bracket.

• Position a spirit level at the bottom of the hood to check side to side leveling.

Rear mounting hooks

Rear view

Engage flange on motor housing into slots

6 LEVEL THE HOOD

This hood has built-in levelers on the mounting hooks at each side. Use a long Phillips screwdriver from the front to access the levelers.

• Carefully lay the hood on its back.

• Fasten the hood to the motor housing from the bottom, using 6 screws.

Front side

Levelers

Bottom view

Rear side

• Join two cable connectors at the front of the hood.

To Lights

• Use the top screw hole in the leveler to raise or lower the hood on that side.

• Use the bottom screw hole to pull the hood tight against the wall surface.

To

Control

Panel

17

Screw hole

• Mark hole location at the bottom of the hood.

• Remove the hood. If the bottom screw hole does not enter a stud, enlarge the hole to 3/8 d

and install wall fastener anchors.

• Place the hood back onto the mounting bracket, check level again and install the wall fastener.

Installation Instructions

,167$//$7,21³5(&,5&8/$7,1*

7 SIZE AND CUT DUCT PIECE

• Hold upper air deflector with duct connector against the ceiling.

• Measure from the bottom of the air deflector to the top of the hood as shown. Reduce

Measure length that dimension by

1" to facilitate installation.

The duct will cover and overlap the deflector and the hood outlets.

Duct length

CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved anti-oxidant compound and aluminum-to-copper connectors.

AVERTISSEMENT :

Si la maison n’est pas câblee avec deux fils et un fil de terre, l’installateur doit installer un fil de terre.

Quand les fils sont en aluminium, il faut prendre soin d’utiliser des connecteurs aluminium à cuivre avec une pâte antioxydante approuvée par U.L.

• Remove junction box cover and knockout on the left side.

Knockout

Deflector

• Cut the duct piece to size and slip onto the bottom of the deflector.

• Place the assembled deflector and duct over the exhaust outlet.

• Hold the assembly against the duct bracket.

• Drive 4 screws into the bottom of the deflector and into the bracket.

• Use duct tape to seal duct to the deflector and at the exhaust outlet.

• Secure the house wiring to the junction box with a strain relief.

House wiring

18

• Connect white leads to branch circuit white lead.

• Connect black leads to branch circuit black lead.

• Connect green/yellow leads to branch circuit green lead or bare ground lead.

• Secure all connections with wire nuts on each electrical connector.

• Push wires into junction box and replace cover.

Be sure wires are not pinched.

• Secure J-Box cover with original screw.

Installation Instructions

,167$//$7,21³5(&,5&8/$7,1*

INSTALL DUCT COVERS

• Place the decorative duct covers on top of the hood.

Mounting screw holes

NOTE:

The inside piece has holes on one end intended for use when the hood is installed for recirculating purposes.

Be sure the vented end is at the top; the vent holes will be visible in this installation.

Vent holes

The inside duct piece must slip into the folded ends on the outer section.

Duct cover support bracket

INSTALL FILTERS

IMPORTANT:

Check to be sure that the main ON/

OFF switch next to the motor is in the ON position.

Charcoal filter

• Install the black charcoal filter into the center opening. Secure the filter with thumbscrews on each side.

Metal filter

Filter Lock

Upper duct cover

Duct cover support bracket

Lower duct cover

• Tip the filter into the left or right side of the opening. Lift the filter to the opposite side and into the filter lock.

• To remove the filter, pull the filter lock downward.

FINALIZE INSTALLATION

• Remove all tape and packing material.

• Refer to the Owner’s Manual for operating instructions.

Lower duct cover seat

• Extend the inner duct upward to the ceiling bracket.

• Secure duct cover to ceiling bracket with 2 screws.

19

49-80328-3

02-13 GE

Printed in Mexico

NOTE:

While performing installations described in this book, safety glasses or goggles should be worn.

For Monogram

®

local service in your area, call

1.800.444.1845.

NOTE:

Product improvement is a continuing endeavor at

General Electric. Therefore, materials, appearance and specifications are subject to change without notice.

GE Appliances & Lighting

Appliances

General Electric Company

Louisville, KY 40225 monogram.com

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project