5991 1056EN General Catalog

5991 1056EN General Catalog
Buy online:
www.agilent.com/chem/store
Contact us:
www.agilent.com/chem/contactus
This information is subject to change without notice.
© Agilent Technologies, Inc. 2012
Printed in Canada October 31, 2012
5991-1056EN
Scan the QR code
with your smartphone
for more information
THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG
For more information
GENERAL
CHROMATOGRAPHY
GENERAL CHROMATOGRAPHY
Your Essential Resource for Supplies
GENERAL CHROMATOGRAPHY
SUPPLIES
NEW FORMAT. SAME ESSENTIAL RESOURCE.
The Essential Chromatography and Spectroscopy Catalog is now available
in a boxed set to help you easily find the products and information you need.
Each catalog is your essential resource for:
• Product photos and ordering information
• Troubleshooting tips
• Selection guides and applications
• Maintenance schedules
• Compatibility charts
Minimize contamination and ensure accurate,
reproducible results
As the world’s premier measurement company, Agilent is uniquely positioned to offer you the widest
selection of parts and supplies. All are engineered or selected by our experienced design teams,
manufactured to our demanding specifications, and tested under the strictest conditions.
Your boxed set includes comprehensive information for Agilent's
entire portfolio of Chromatography and Spectroscopy columns
and supplies in the following catalogs:
General Chromatography Supplies – Minimize contamination and ensure accurate,
reproducible results with our selection of vials, syringes, gas purification systems, fittings
and tools, and electrochemistry meters.
• Vials, caps and septa are designed to work flawlessly with your autosampler’s gripping and
injection mechanisms – eliminating breakage and leaks that can cause unnecessary downtime,
expensive repairs, and sample loss. We have also expanded our portfolio to include MS analyzed kits,
Agilent Certified Vials, and NEW Agilent CrossLab Vials for non-Agilent autosamplers.
Sample Preparation Products for Chromatography – Reliably extract and concentrate
samples from complex matrices with Bond Elut SPE cartridges, pre-packaged QuEChERS kits,
sample filtration products, dried matrix spotting cards and pre-measured TOXI-TUBES.
• Manual and autosampler syringes boost performance along every step of your sampling process.
Designed for accuracy, reliability and ease of use, Agilent syringes ensure exact measurement,
transport, and delivery of liquids necessary for sample preparation and injection.
• Renewable gas purification system extends column life and reduces baseline noise by removing
GC and GC/MS – Achieve excellent, reproducible performance for difficult samples with
ultra inert solutions for GC, premium inlet supplies, Agilent J&W GC columns and standards, and more.
oxygen, water, and hydrocarbons from carrier gasses. One renewable cartridge can support up to
four GC systems, while delivering the same filtration capacity as multiple competitive cartridges.
• Gas Clean filter system prevents dirty gas from jeopardizing your analysis. Oxygen, hydrocarbons,
and moisture can decrease GC sensitivity; they can also activate glass wool in liners and accelerate
septa degradation, causing high background noise and ghost peaks. Inserting a gas clean filter
immediately before your GC inlet greatly reduces the level of impurities, improving trace analysis.
• Fittings and tools make life in the lab easier by keeping your instruments running in top form.
• Electrochemistry meters are designed by chromatographers for chromatographers to give you
rugged simplicity and fast, reliable data. Features such as user-friendly controls, waterproof
connectors, and multi-parameter measurement capabilities make Agilent pH, DO, ISE, conductivity
and multi-parameter meters your first choice for a broad range of applications.
LC and LC/MS, including CE and CE/MS – Maximize system performance and produce
quality results time after time with LC capillaries, lamps, and the entire family of ZORBAX LC columns
for small molecules, biomolecules and GPC/SEC.
Spectroscopy – Satisfy your growing demand to screen large numbers of samples, faster, with supplies
and standards for Atomic Absorption, ICP-OES, ICP-MS, MP-AES and Molecular Spectroscopy.
For more information and to request additional catalogs,
please visit www.agilent.com/chem/catalog
Special Offers from Agilent
You don't have to look far to find valuable offers that feature high-performance
columns and supplies, accessories, and more.
Just go to www.agilent.com/chem/specialoffers to find out about our latest offers.
And be sure to check back often, because we'll update this page throughout the year!
For more details about these offers, contact your local Agilent office or Authorized Agilent Distributor.
Table of Contents
Agilent Solutions, Services and Support .......................2
Agilent Syringes ................................................................ 60
Featured Products .............................................................6
Agilent Autosampler Syringes.........................................63
Agilent Vials and Closures...............................................8
Manual Syringes ................................................................69
MS Analyzed Vial Kits.......................................................14
Agilent CrossLab Syringes............................................... 77
Certified Screw Top Vials and Closures .........................15
CTC Autosampler Supplies .............................................. 86
Crimp Top Vials and Closures ..........................................19
Gas Management .............................................................. 91
Certified Microvolume Inserts.........................................21
Carrier Gas Purification.....................................................91
Polypropylene Vials and Closures...................................22
Gas Purification Systems .................................................96
Headspace Vials and Closures ........................................24
In-Line Gas Traps ...............................................................101
Snap Top Vials and Closures............................................28
Flow Meters........................................................................110
Specialty Vials and Closures............................................30
Gas Leak Detector .............................................................111
General Purpose Vials and Caps.....................................33
Regulators, Tubing, and Accessories .............................113
Crimping and Decapping Tools........................................34
Kits, Fittings, Tools and Accessories .............................. 115
Agilent CrossLab Vials and Closures.............................. 36
Electrochemistry ............................................................... 130
Agilent CrossLab Headspace Vials and Closures ........40
Integrators, Integrator Supplies, and Cables ................ 148
Agilent CrossLab Screw Top Vials and Closures .........43
Indices ................................................................................ 151
Agilent CrossLab Crimp Top Vials and Closures ..........49
Ordering Information ........................................................ 158
Agilent CrossLab Snap Top Vials and Closures............51
Agilent CrossLab Polypropylene Vials ...........................54
Agilent CrossLab Micro-V Vials.......................................54
Agilent CrossLab Microvolume Inserts .........................55
Agilent CrossLab Well Plates and Accessories ...........57
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
1
Agilent Solutions
PUT MORE THAN 40 YEARS OF RELENTLESS INNOVATION
BEHIND YOUR EVERY RESULT
By continually raising the standards for technologies that support your routine analyses, Agilent's R&D efforts have led to breakthroughs such as:
• New GC columns that help you achieve higher levels of inertness and column-to-column reproducibility
• LC column choices that deliver the sensitivity and reliability you need for demanding applications
• Cutting-edge sample preparation products that promote reliable extraction and concentration
• Fresh atomic and molecular spectroscopy ideas for identifying and confirming targets and unknowns
Longtime Agilent customers have experienced our commitment firsthand. And now, we look forward to demonstrating
how Agilent's approach to relentless innovation can work to your advantage, too.
C H E M I C A L A N A LY S I S S O L U T I O N S
Food
Forensics
From high-volume screening of vegetables for large numbers of
pesticides to rapid identification of pathogens, Agilent understands
the analytical needs of food producers, shippers, and regulators.
When a new toxin appears, we deploy substantial resources to
quickly help customers develop robust and reliable methods.
Agilent's leading separations, mass spectrometry, and spectroscopy
solutions are emerging as valuable food testing techniques.
Because the careers of world class athletes and many other
individuals hinge on drug testing, it’s critical that those doing
the testing have the highest level of confidence in the results.
Forensics analysts worldwide have grown to depend on
Agilent tools for accuracy, reliability, and speed in this high
stakes, high-throughput field. Our best selling GC, GC/MS
and popular LC and LC/MS are workhorses in forensics labs.
Environmental
Agilent offers more than 40 years of environmental testing and
regulatory expertise. We help government and private labs with
the full range of assays, from routine testing of soils for heavy metals
to detection of pharmaceuticals in groundwater, in concentrations
down to parts per trillion.
Traditional Lab Informatics
The ways labs generate and store data profoundly affect
their efficiency. Agilent offers a rich, integrated suite of
software products built on a set of customer-driven
architectural values with the Agilent OpenLAB Laboratory
Software Suite. OpenLAB delivers superior performance,
open systems integration and investment protection.
Our commitment is to deliver more value across each
step in the life cycle of scientific data – from data collection
and analysis to interpretation and management.
Energy and Fuels
Agilent collaborates closely with process industry customers to offer
analytical systems that meet their needs for separation, detection,
throughput, and support. We’ll even preconfigure custom or standard
analyzers so they arrive at the lab ready-to-go. Agilent’s expertise in
both chemical analysis and life science is a powerful combination for
researching and producing biofuels, including a wide range of analytical
techniques for fatty acid methyl esters (FAMEs). Our newly-expanded
portfolio also offers powerful tools for developing and producing
photovoltaic films and solar panels.
2
Materials Science
Agilent offers a newly expanded portfolio of instruments
used for the research, manufacturing and testing of
advanced materials, from precision optics to pulp, paper
and polymers. Tools for chromatography, atomic absorption
spectroscopy, molecular spectroscopy, X-ray
crystallography, and nuclear magnetic resonance
all support continuous progress in materials science.
LIFE SCIENCE SOLUTIONS
Biopharmaceutical
Genomics
As “multi-omics” studies gain momentum in the search
for new therapeutics, Agilent is uniquely positioned
to provide the instruments, reagents, and powerful
software needed for performing experiments in multiple
disciplines and combining the massive amounts of data
into biological insight.
Pharmaceutical
Drug manufacturing requires the accuracy, sensitivity
and high throughput of other analytical applications,
along with the demands of regulatory record-keeping
and validation requirements. Agilent provides a potent
combination of rugged, high-throughput tools and
unmatched compliance services. Agilent now offers the
market-leading family of dissolution apparatus and sampling
systems that pair perfectly with our HPLC and UV systems.
Proteomics
Research into how large sets of proteins affect the health
of an organism requires special sets of analytical tools.
Agilent has built a formidable arsenal of liquid
chromatograph/mass spectrometers, bioinformatics
systems, multiple affinity protein removal columns, and
OFFGEL electrophoresis for protein identification and
protein biomarker discovery. Accurate-Mass mass
spectrometry and the microfluidic HPLC-Chip/MS are
two Agilent innovations speeding the work of proteomics
researchers around the globe.
Metabolomics
Collections of small molecules are increasingly being seen
as rich sources of biomarkers, but studying metabolites
presents many challenges. The need for speed, accuracy,
and powerful interpretation capabilities in looking at
chemical profile snapshots is underscored because
molecules are constantly entering, leaving or changing
within the metabolome. Agilent’s GC, LC, NMR and MS
portfolios, along with our excellent bioinformatics offerings,
user-customizable METLIN metabolite database for
LC/MS, and the industry’s first commercial GC/MS
retention time locked metabolite library align well with
needs of metabolomics researchers.
Agilent is a global leader in microarrays, scanners, and reagents used
in a wide variety of genomic-based disease research experiments.
Our SureSelect Target Enrichment System dominates the category,
streamlining next generation sequencing studies worldwide. Agilent
offers a wide range of catalog microarrays and a highly-developed
capability to produce custom arrays featuring ink jet-based SurePrint
fabrication and the eArray on-line design tool. All Agilent microarrays
feature highly sensitive, selective 60-mer probes. With as many as eight
arrays printed on a standard 1 x 3 in. slide, the cost per experiment
becomes very affordable.
Life Science Informatics
Mirroring its extensive instrument portfolio, Agilent offers the industry’s
most extensive suite of bioinformatics software, helping users derive
knowledge from complex genomic, proteomic, metabolomic and other
biological data. This includes DNA Analytics for analyzing CGH, ChIP and
methylation microarray data. The GeneSpring suite includes informatics
software for microarray-based gene expression data, genotyping data,
and GeneSpring MS, which are useful for analyzing mass spec data from
proteomics and metabolomics experiments and comparing complex
datasets to explore biological questions from multiple perspectives.
Lab Automation
To meet the skyrocketing demand for more throughput and automation,
Agilent has substantially expanded its lab automation offerings. The
Agilent line of liquid handlers and microplate processors are designed to
streamline high-volume life science workflows. Agilent is also continually
upgrading its advanced autosamplers for LC, GC, LC/MS and GC/MS,
adding functionality and speed to reflect the performance of its
advanced instruments.
Vacuum Technology
Agilent works with customers to solve vacuum challenges from
experiments in high-energy physics to developing systems for producing
flat panel displays. Agilent manufactures vacuum systems used in its own
mass spectrometry instruments as well as those of other manufacturers.
Agilent's vacuum technology has been proven by the most powerful
physics experiment ever built, CERN’s Large Hadron Collider machine,
which was used in the discovery of the Higgs boson particle.
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
3
AGILENT SERVICE AND SUPPORT
Agilent Service and Support
for Instrument Systems
Focus on what you do best
For over 40 years, Agilent has been building and maintaining the instruments you count on to stay competitive
and successful. Trust us to protect your investment with a broad portfolio of services, backed by a global
network of experienced service professionals dedicated to the productivity of your lab.
Get the Agilent
Service Guarantee
Should your instrument require
service while covered by an
Agilent service agreement, we
guarantee repair or we will
replace your instrument for free.
No other company offers this level
of commitment to keep your lab
up and running at peak efficiency.
Agilent Advantage Service Plans
The best service available for your Agilent instruments
Agilent offers a flexible range of service plans so that you can choose the level of coverage that is best
for your lab.
• Agilent Advantage Gold – Priority-one coverage for ultimate uptime and productivity
• Agilent Advantage Silver – Comprehensive coverage for dependable laboratory operations
• Agilent Advantage Bronze – Total repair coverage at a fixed annual price
• Agilent Repair Service – Basic coverage for reliable instrument repair
Agilent Advantage service plans include Agilent Remote Advisor for real-time remote monitoring
and diagnostics. Through secure internet connections, you can interact with Agilent service professionals,
receive detailed asset reports, and configure text or email alerts to notify you before problems occur –
helping you to maximize instrument uptime and optimize laboratory workflows.
Agilent Compliance Services
Equipment qualification that meets
the most stringent requirements
Enterprise Edition Compliance was developed to streamline compliance across your entire lab. Used globally
in regulated labs, including standards organizations and regulatory agencies, Enterprise Edition enables you to:
Laboratory decision makers
and users ranked Agilent
as their first choice for
general laboratory
compliance services.
• Improve qualification efficiency by automating protocols across platforms to ensure greater efficiency
and minimize regulatory risk
• Standardize your entire compliance operation with robust test designs that work with all your instruments
• Add, remove or reconfigure tests based upon your unique user requirements
• Significantly reduce staff review time with consistently formatted, computer generated,
tamper-proof reports
4
AGILENT SERVICE AND SUPPORT
Agilent Education and Consulting Services
Our best minds, working for you
Make the most of your instrument with training and consulting from the same experts who designed
the instruments, software and processes you use every day.
• Classroom and on-site training in instrument operation, troubleshooting and maintenance
• Customized consulting services to meet your lab’s unique needs
The Agilent Value Promise –
10 Years of Guaranteed Value
In addition to continually evolving products, we offer something else unique to the industry – our 10-year
value guarantee. The Agilent Value Promise guarantees you at least 10 years of instrument use from your
date of purchase, or we will credit you with the residual value of the system toward an upgraded model.
Not only does Agilent ensure a reliable purchase now, but we also ensure that your investment is just as
valuable in the future.
For more detailed information,
please go to www.agilent.com/chem/services
or contact your local Agilent Services and Support representative.
Technical Support at work for you
Have a hardware, software, application, instrument repair or troubleshooting question? Agilent's technical
experts are available to answer your questions. With years of laboratory experience, our technical support
specialists can provide in-depth knowledge and experience.
For questions pertaining to supplies found in this catalog, contact your local Agilent office or Authorized
Agilent Distributor or visit www.agilent.com/chem/techsupport
Need more information?
Visit www.agilent.com/chem/contactus to:
• Locate your nearest Agilent office or distributor for expert technical support.
• Get fast sales and product assistance by phone. Simply use the scroll-down menu to select your country.
• Receive email assistance using our convenient online forms.
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
5
FEATURED PRODUCTS
Agilent Gas Clean Filters
The Agilent Gas Clean Filter System provides enhanced gas quality for maximum productivity. Clean gases reduce the risk
of column damage, sensitivity loss, and instrument downtime. Oxygen, hydrocarbons and moisture can cause loss of sensitivity
and accuracy of the GC, and damage your column and consumables. Inserting a Gas Clean Filter System in the gas line immediately
before the instrument inlet greatly reduces the level of impurities and helps you detect any problems before they occur.
Turn to pages 96-99.
Agilent Ultra Inert Solutions
Agilent is leading the way in flow path inertness with their industry-leading Agilent
J&W Ultra Inert GC Column family and the Agilent Ultra Inert Liner. Whether you are
analyzing difficult, active food and environmental samples or screening for drugs of abuse,
our Ultra Inert solutions help ensure an inert GC flow path for higher sensitivity, accuracy,
and reproducibility…especially at trace levels. For more information, visit
www.agilent.com/chem/ultrainert
Agilent Electronic Crimper and Decapper
The Agilent Electronic Crimper and Decapper is much easier to use than a manual crimper, and is more
likely to give you a secure seal every time. The crimper also increases lab productivity because you don’t
waste time refixing poor seals and cleaning up broken glass and spilled samples. You can also be confident
that you do not risk losing potentially valuable samples.
Turn to page 34.
Agilent Syringes
Whether you need an autosampler or manual syringe, there are two key features consider when choosing
the right syringe – identifying your sample type and establishing the smallest volume to be dispensed or
injected. Agilent offers syringes for all sample types in all the dimensions you are ever likely to need,
for accurate and effective sampling.
Turn to page 60.
6
FEATURED PRODUCTS
Agilent
CrossLab
Agilent CrossLab Supplies
Agilent CrossLab is a growing portfolio of GC and LC supplies critical to instrument performance and
productivity. They are manufactured to perform seamlessly with a variety of analytical instruments in your
lab, regardless of make or model. When you choose Agilent CrossLab, you know you'll get:
• Over 40 years of chromatography expertise and on-going innovation
• The same commitment to quality inherent in all Agilent products
• Optimal performance for routine and challenging applications
• Convenience of consolidated purchasing
All with our risk-free, 90-day, money-back guarantee.
Agilent CrossLab HPLC supports instruments from Waters, Shimadzu, Dionex
(now part of Thermo Scientific), CTC Analytics, and more. The comprehensive range
includes detector lamps, autosampler vials and closures, well plates and sealing
mats, autosampler syringes, pump and valve supplies, capillaries, tubing, and fittings,
and performance maintenance kits. Put Agilent CrossLab HPLC quality supplies
to work across your lab.
Agilent CrossLab GC works with instruments from Bruker (formerly Varian),
CTC Analytics, PerkinElmer, and Shimadzu, with more on the way. The family
comprises autosampler syringes to autosampler vials, Agilent Ultra Inert inlet liners
to non-stick liner O-rings, capillary column ferrules to column nuts, vials, caps, septa,
and more. Experience the same Agilent quality solutions you know and trust, now for
your non-Agilent GCs.
All Agilent Crosslab high quality supplies are backed by Agilent's worldwide technical support
and dependable availability and delivery.
For information on Agilent CrossLab Vials, turn to page 36
For information on Agilent CrossLab Syringes, turn to page 77-78
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
7
AGILENT VIALS AND CLOSURES
Agilent Vials and Closures
Common questions about Agilent vials and caps
Why is it important to use Agilent Certified vials
on my Agilent autosampler?
Agilent Certified vials are the only vials in the industry designed and tested for full compatibility with our
autosamplers. The same attention and precision that go into designing our instruments, columns, and parts
also go into designing these vials. Many Agilent autosamplers use a robotic arm to grip vials by the neck.
Therefore, it is critical that the vial neck and shoulder are the proper height to prevent dropped vials and lost
samples. Only Agilent Certified vials are designed for use on Agilent autosamplers; competitor products
simply do not meet our exact specifications, which can lead to costly instrument downtime and potential
loss of your precious samples.
Is the same true for Agilent Certified caps and inserts?
To avoid leakage and sample loss due to evaporation, inserts must sit neatly in the vial – and the entire
assembly must be tightly sealed when capped. You should also consider the depth of your autosampler
needle when using an insert to prevent needle damage and ensure proper sample uptake.
The threads on the Agilent Certified screw vials are designed precisely to match the threads on Agilent
Certified caps. Using a non-Agilent Certified cap on these vials will not create a secure, tight seal and will
lead to sample loss. In addition, Certified crimp vials and caps are tested over 100,000 times on our Agilent
autosamplers to confirm a proper fit and secure seal.
Do I need to be concerned about the compatibility
of my sample with my vials?
For highly sensitive samples such as pesticides or semivolatiles, as well as samples that are prone to sudden
shifts in pH, deactivated vials are best, because their surface is more hydrophobic and inert. For more
exacting, demanding applications, such as mass spectrometry, deactivated vials are recommended to
prevent sample interactions prior to analysis.
Polypropylene vials are an excellent choice for biological applications and for applications involving samples
with high metal content, such as ion chromatography, AA, or ICP-MS. Agilent thoroughly tested and
evaluated a variety of polypropylene materials prior to selecting the grade used in our polypropylene vials.
Our polypropylene vials have the lowest levels of extractables to ensure integrity of your sample.
8
AGILENT VIALS AND CLOSURES
Can I count on consistency from one vial to the next?
Autosampler vials can vary from their stated size and wall weight if tolerances are not tightly controlled.
This can affect the volume of sample in the vial, which is especially problematic when working with
small amounts of sample. Our tight control of tolerances extends through the entire manufacturing
process, from the initial design to the final opto-electronic screening process, which inspects every
single vial and cap for accuracy.
Agilent Certified vials conform to the industry’s tightest tolerances to ensure consistency from lot to lot,
as well as from one vial to the next.
Why should I buy my vials from Agilent?
Vial integrity, cleanliness, and consistency are critical for today’s demanding applications. That is why
Agilent vials and caps are designed using the same engineering expertise that is built into Agilent
instruments. All Agilent Certified vials are manufactured in ISO 9001 clean environments, must pass
a 33-point visual inspection, and are uniquely packaged to stay clean and secure during shipment.
Why It Is Critical to Use Agilent Certified Vials and Closures on Agilent Autosamplers
Common Problems
Effects
Benefits of Agilent Certified Vials and Caps
Inconsistency with vial bottom thickness
ü Sample draw inconsistency
ü Damaged needle
Consistent and valid relative standard deviation (RSD) values
Autosampler sequence interruption
ü Mishandled or dropped vials
ü Loss of precious sample
Confidence in unattended operation
Undetected improper seal
ü Sample loss/evaporation
ü Possible sample contamination
Proper sealing for accurate results
Dislodged or misaligned septa
ü Sample loss
ü Sample contamination
Accurate results
Ghost peaks
ü Contamination by cap septa
Chromatographic purity test that eliminates outliers and analysis errors
TIPS & TOOLS
Agilent has made vial, cap and septum selection easy with its new Interactive Vial Selection Tool, available online in both desktop and mobile
versions. The tool identifies the right vial and closures for your particular application, and provides the rationale for the choices offered.
Visit www.agilent.com/chem/SelectVials
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
9
AGILENT VIALS AND CLOSURES
Protect sample integrity by choosing
the right septa for your application
Proper septa selection is critical to preventing contamination and avoiding damage to the needle
and instrument. Here are some questions you should ask:
Are the septa chemically compatible with your samples
and solvents?
The chart below summarizes chemical compatibility and incompatibility. Agilent provides this septa
compatibilty as a guide and a starting reference point. We realize that chemical compatibility can vary
depending on the concentration of the solvent, the temperature, the molecular weight of the solvent,
and other factors. Therefore it is always recommended you try a variety of septa to determine the best
one for your analysis.
Septa Chemical Compatibility
PTFE
PTFE/Silicone
PTFE/Silicone/PTFE*
PTFE/Red Rubber
Acetonitrile
3
3
3
3
Hydrocarbons (hexane,
heptane, methane)
3
3
3
3
3
3
PTFE/Butyl
3
3
Methanol
3
Benzene
3
3
THF
3
3
Toluene
3
DMF
3
3
3
3
3
DMSO
3
3
3
3
Ether
3
3
3
Chlorinated Solvents
(methylene chloride)
3
Alcohols (ethanol)
3
3
3
Acetic Acid
3
3
3
Acetone
3
3
3
Phenol
3
3
Cyclohexane
3
3
3
3
3
3
3
3
3
3
3
*PTFE/silicone/PTFE has the same chemical compatibility of PTFE ONLY UNTIL PUNCTURED
10
Viton
3
3
3
3
AGILENT VIALS AND CLOSURES
Will my application require repeat injections from the same vial
or storage of the sample?
Resealability is an important factor to consider when selecting septa. PTFE/red rubber septa are not
recommended for multiple injections or for samples that need to be stored for further analysis. When
applications require a longer time between injections or any type of standard additions, PTFE/silicone/PTFE
septa are always best.
What force is required to penetrate the septa?
Generally, silicone septa are more easily pierced than red rubber or butyl septa. For thicker, hard-to-pierce
septa, a small gauge (23 gauge) needle may be required. Or an S-needle as they are stronger.
Pre-slit septa are the best option for the easiest penetration and will reduce the likelihood of coring.
All Agilent Certified septa are designed for optimal use with Agilent autosamplers and for proper fit
in the caps.
Cap and Septa Compatibility
Temperature range
Use for multiple
injections
Price
Resistance to coring
Recommended for
storage
Best for
High
Performance
Septa
Thin PTFE
40 °C to 300 °C**
Up to 260 °C
No
No
Yes
Yes
No
No
No
More expensive
Very economical
Economical
Most expensive
Very economical
Economical
Economical
Excellent
None
Excellent
Excellent
None
None
None
No
No
Yes
Yes
No
No
No
High temperature
headspace
applications
PTFE/Silicone*
PTFE/
Silicone/
PTFE*
PTFE/
Red Rubber
Viton
Butyl
-40 °C to 200 °C -40 °C to 200 °C -40 °C to 90 °C -40 °C to 260 °C -50 °C to 150 °C
Chlorosilanes,
Chlorinated
Organic solvents,
Most common
Superior
Superior
acetic acids;
HPLC and GC
performance more economical solvents, higher
chemical
temperatures
impermeable to
analyses, not as
for ultra trace option for single
inertness,
injections
gases
resistant to
analysis, repeat
short cycle times,
coring as P/S/P injections, internal
and single
standards
injections
*Agilent silicone is platinum cured (versus peroxide cured), making it more inert and less likely to interact with samples
**For up to one hour
TIPS & TOOLS
Agilent has made vial, cap and septum selection easy with its new Interactive Vial Selection Tool, available online in both desktop and mobile
versions. The tool identifies the right vial and closures for your particular application, and provides the rationale for the choices offered.
Visit www.agilent.com/chem/SelectVials
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
11
AGILENT VIALS AND CLOSURES
What temperature range does my application require?
Septa can degrade at higher temperatures, causing contamination of your samples. Red rubber septa
are only stable up to 90 °C and therefore are not a good option for higher temperature applications.
Generally, PTFE-lined silicone septa provide the best compatibility with a wide range of temperatures.
For newer headspace applications that require temperatures up to 300 °C, Agilent offers the
new High Performance Septa, made of special proprietary materials that minimize degradation
at extreme temperatures.
How do I avoid common issues caused by septa?
Coring
Coring occurs when the needle diameter is too large for the septa or when the septa material is not durable
enough to withstand repeat injections. When this happens, septa material can flake off into the vial and
contaminate the sample. Here is how to prevent coring:
• Choose a PTFE-lined septum to prevent septa material from entering the sample
• Make sure the needle is not damaged, and consider a side-entry needle instead of a conical needle
• Use pre-slit septa, which will virtually eliminate coring
Vacuum Generation
Sometimes withdrawing volume from a sealed vial can create a vacuum. A few simple steps can prevent
this from happening:
TIPS & TOOLS
For highly sensitive samples,
we recommend PTFE-lined
(“sandwiched”) septa, because
the PTFE layers act as a chemically
resistant barrier.
TIPS & TOOLS
Septa that are too thick can
prevent the cap from fitting
properly on the vial. Agilent
Certified septa are designed
for use in our Certified caps.
12
• Use pre-slit septa to help equalize the pressure on both sides of the cap
• Do not overfill vials
• Do not take more than 50 µL (from a 2 mL vial) in one injection
AGILENT VIALS AND CLOSURES
Agilent Vial Identification Chart and Actual Fill Volumes
Wide Opening
Screw Top Vials
(9 mm)
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap:
32 mm x 12 mm
1.5 mL
5182-0714
5182-0717
32 mm x 12 mm
1.2 mL
5183-2030
5182-0717
32 mm x 12 mm
250 µL
5188-6591
5182-0717
Narrow Opening
Screw Top Vials
(8 mm)
32 mm x 12 mm
1.3 mL
5184-3550
5182-0717
32 mm x 12 mm
1.5 mL
5183-4428
5183-4442
Polypropylene Vials
Crimp/Snap Top
32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm
250 µL
250 µL
250 µL
250 µL
0.7 mL
5188-2788
9301-0977
5190-2242
5188-5390
5182-0567
5182-0552 (crimp) 5182-0552 (crimp) 5182-0552 (crimp)
5182-0717
5182-0717
5182-3458 (snap) 5182-3458 (snap) 5182-3458 (snap)
Glass Insert
Glass Insert
Wide Opening Crimp Top Vials (11 mm)
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap:
32 mm x 12 mm
1.5 mL
5181-3375
5182-0552
32 mm x 12 mm
1.2 mL
5182-3454
5182-0552
32 mm x 12 mm
250 µL
9301-1388
5182-0552
32 mm x 12 mm
1.3 mL
5184-3551
5182-0552
Wide Opening Snap Top Vials
32 mm x 12 mm
1.7 mL
5182-0544
5182-3458
Inserts for Wide Opening Vials (11 mm & 9 mm)
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap:
30 mm x 5.6 mm
250 µL
5181-1270
31 mm x 5.6 mm
250 µL
5183-2085
Screw Top
32 mm x 12 mm
1.4 mL
5183-4510
5182-3458
32 mm x 12 mm
0.7 mL
5184-3552
5182-3458
32 mm x 12 mm
0.3 mL
5188-6593
5182-3458
Inserts for Narrow Opening Vials (8 mm)
31 mm x 5.6 mm
400 µL
5181-3377
28 mm x 4.8 mm
150 µL
5183-2088
31 mm x 4.8 mm
150 µL
5183-2089
31 mm x 4.8 mm
200 µL
5183-2090
Headspace Vials
Mini Vials
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap:
75 mm x 22 mm
20 mL
5182-0837
5183-4477
45 mm x 22 mm
10 mL
5182-0838
5183-4477
75 mm x 22 mm
20 mL
5183-4474
5183-4477
45 mm x 22 mm
10 mL
5183-4475
5183-4477
–
500 µL
5180-0806
5180-0842
–
700 µL
5180-0805
5180-0842
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
Specialty Vials
37 mm x 22 mm
6 mL
9301-1419
9301-1425
45 mm x 15 mm
4 mL
5183-4448
5183-4464
Large Volume
Vials
37 mm x 22 mm
6 mL
9301-1377
9301-1379
13
AGILENT VIALS AND CLOSURES
MS Analyzed Vial Kits
Agilent MS Analyzed Vial Kits end the need to pre-test or to re-run samples due to unexpected peaks.
All MS Analyzed Vial Kits include a Certificate of Analysis that contains accurate, lot-specific, and fully
traceable LC/MS and GC/MS signal traces, as well as critical physical dimensions. Agilent's new
MS Analyzed Vial Kits provide lot-specific test results for greater confidence in your results.
• All vials are lot-tested by both GC/MS and LC/MS using Agilent systems
• Manufactured for full-warranted compatibility with Agilent GC and LC autosamplers
• Packaged in a unique box designed to reduce vial breakage
• Packed in a clean environment using clean packaging to reduce contamination
• Available in both crimp top and screw top closures
• Larger write-on spots for easier labeling and identification
• Conveniently packaged in a combination pack with 100 vials and 100 caps/septa
MS Analyzed Vial Kits
Vial Type
Septa Type
Cap Color
100/pk
PTFE/red silicone septa
Blue
5190-2277
Screw Top MS Analyzed Vial Kits
Clear
Screw top MS analyzed vial kit, 5190-2277
Clear with write-on spot
PTFE/red silicone septa
Blue
5190-2278
Amber
PTFE/red silicone septa
Blue
5190-2279
Amber with write-on spot
PTFE/red silicone septa
Blue
5190-2280
PTFE/white silicone septa
Silver aluminum
5190-2281
Crimp Top MS Analyzed Vial Kits
Clear
Clear with write-on spot
PTFE/white silicone septa
Silver aluminum
5190-2282
Amber
PTFE/white silicone septa
Silver aluminum
5190-2283
Screw top MS analyzed vial kit, 5190-2280
Crimp top MS analyzed vial kit, 5190-2282
14
Certificate of Analysis
signed by Agilent's Quality Manager
AGILENT VIALS AND CLOSURES
Certified Screw Top Vials and Closures
Combine the excellent autosampler handling of a crimp cap profile with the ease of a screw cap.
The screw caps and precision fit septa give a secure seal with microvolume inserts.
• Certified for full warranted compatibility with Agilent autosamplers
• 2 mL, 12 x 32 mm, 9 mm diameter
• Packaged in a unique box designed to reduce vial breakage
• 40% larger opening than standard narrow opening vials
• Unique thread design for consistently secure seal
• Precision-formed neck for optimal robotic arm handling
• Rigorous quality assurance for dimensional consistency from lot-to-lot
• Optional ceramic write-on spot with fill marks
2 mL Wide Opening Screw Top Glass Vials
Description
100/pk
1000/cs*
Clear
5182-0714 5183-2067
Clear, write-on spot
5182-0715 5183-2068
Amber
5188-6535 5188-6536
Amber, write-on spot
5182-0716 5183-2069
Deactivated Vials
Clear
5183-2070
Clear, write-on spot
5183-2071
Amber, write-on spot
5183-2072
*Case includes 10 packs of 100 vials
LC Vials and Closures
Description
Unit
Part No.
6 mL Screw Top Vials and Closures
Clear, flat bottom
100/pk 9301-1377
Screw caps, 16 mm
100/pk 9301-1379
PTFE/silicone septa
100/pk 9301-1378
PTFE/silicone septa, pre-slit
100/pk 5188-2758
5 mL Screw Top Vials
Clear, high recovery
30/pk
5188-5369
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
15
AGILENT VIALS AND CLOSURES
Screw Caps for 2 mL Vials
Color
Septa Type
Blue
PTFE/red silicone septa
3
5182-0717 5185-5820 5190-1599
PTFE/white silicone septa
3
5182-0720 5185-5863
PTFE/silicone/PTFE septa
3
5182-0723 5185-5862
Pre-slit PTFE/silicone septa
3
5183-2076 5185-5865
PTFE-lined solid top
3
5183-2075
Open top, no septa
3
5182-0728
PTFE-lined solid top screw caps
for 2 mL vials, 5183-2075
Green
Polypropylene caps with bonded septa,
5185-5823
Screw caps with septa
Red
Certified
100/pk
500/pk
Bonded PTFE/silicone septa
5185-5823
Bonded pre-slit PTFE/silicone
septa
5185-5824 5040-4649
PTFE/red silicone septa
3
5182-0718 5185-5829
PTFE/white silicone septa
3
5182-0721 5185-5864
PTFE/silicone/PTFE septa
3
5182-0724 5185-5861
Pre-slit PTFE/silicone septa
3
5183-2077
Open top, no septa
3
5182-0727
PTFE/red silicone septa
3
5182-0719
PTFE/white silicone septa
3
5182-0722
PTFE/silicone/PTFE septa
3
5182-0725
Pre-slit PTFE/silicone septa
3
5183-2078
5182-0726
Open top, no septa
3
Black
PTFE/red silicone septa
3
5185-5838
Purple
PTFE/silicone septa
3
5040-4681
Light turquoise PTFE/silicone septa
3
5040-4683
1000/pk
Certified Septa for Wide Opening (9 mm) Screw Caps
Septa Type
Color
100/pk
PTFE/red silicone
Ivory
5182-0731
PTFE/white silicone/red PTFE
Red
5182-0729
Pre-slit PTFE/white silicone
Blue
5183-2074
PTFE/white silicone
Red
5182-0730
Screw Cap Pack for 7696 Sample Prep Workbench
16
Description
Septa Type
Part No.
Multicolor screw cap pack
Includes 50/pk of each color: blue, green, red,
light turquoise, purple
PTFE/silicone septa
5040-4682
AGILENT VIALS AND CLOSURES
Certified 2 mL Screw Top Vial Packs
Pre-assembled packs come ready-to-use with the cap and septum of your choice attached to the
vial. A time- and labor-saving product for use with your Agilent autosampler or any rotating tray
automatic sampler.
Certified 2 mL Screw Top Vial Packs
Vial Type
Septa Type
Cap Color
100/pk
Clear
PTFE/red silicone septa
Blue
5182-0553
Clear with write-on spot
PTFE/red silicone septa
Blue
5182-0864
Amber with write-on spot
PTFE/red silicone septa
Green
5182-0554
Clear
PTFE/silicone/PTFE septa
Blue
5182-0555
5182-0866
Clear with write-on spot
PTFE/silicone/PTFE septa
Blue
Amber with write-on spot
PTFE/silicone/PTFE septa
Green
5182-0556
Clear
PTFE/silicone septa
Blue
5182-0557
Clear with write-on spot
PTFE/silicone septa
Blue
5182-0865
Amber with write-on spot
PTFE/silicone septa
Green
5182-0558
Clear
Pre-slit PTFE/silicone septa
Blue
5183-2082
Clear with write-on spot
Pre-slit PTFE/silicone septa
Blue
5183-2083
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
Pre-assembled vial pack
17
AGILENT VIALS AND CLOSURES
Certified Screw Top Vial Convenience Packs
Convenience packs are an easy way to get 500 of each component using one part number. Packed
in our six-drawer, reusable blue plastic cabinet, 500 vials and caps with septa installed are kept handy
and dust-free.
Certified Screw Top Vial Convenience Packs
Screw top vial convenience kit
18
Vial Type
Septa Type
Clear
PTFE/red silicone septa
Cap Color 500/pk
Blue
5182-0732
Clear with write-on spot
PTFE/red silicone septa
Blue
5182-0867
Amber with write-on spot
PTFE/red silicone septa
Green
5182-0733
Clear
PTFE/silicone/PTFE septa
Blue
5182-0736
Clear with write-on spot
PTFE/silicone/PTFE septa
Blue
5182-0869
Amber with write-on spot
PTFE/silicone/PTFE septa
Green
5182-0737
Clear
PTFE/silicone septa
Blue
5182-0734
Clear with write-on spot
PTFE/silicone septa
Blue
5182-0868
Amber with write-on spot
PTFE/silicone septa
Green
5182-0735
Clear
Pre-slit PTFE/silicone septa
Blue
5183-2079
Clear with write-on spot
Pre-slit PTFE/silicone septa
Blue
5183-2080
Amber with write-on spot
Pre-slit PTFE/silicone septa
Green
Clear
Bonded, pre-slit PTFE/silicone septa Blue
5183-2081
5067-0205
AGILENT VIALS AND CLOSURES
Crimp Top Vials and Closures
The wide opening crimp cap provides a larger target area for improved autosampler needle accuracy.
Select from five cap colors and a variety of septa. Whatever your crimp top vial needs, Agilent has what
you are looking for.
• Certified for full warranted compatibility with Agilent autosamplers
• 2 mL, 12 x 32 mm
• Available in unique packaging designed to reduce vial breakage
• Tightly controlled crown for improved crimping
• Precision-formed neck for improved autosampler handling
• Rigorous quality assurance provides dimensional consistency from lot-to-lot
• Optional ceramic write-on spot with fill marks
2 mL Wide Opening Crimp Top Vials
Description
Certified
100/pk
1000/cs*
Clear
3
5181-3375 5183-4491
Clear, write-on spot
3
5182-0543 5183-4492
Amber, write-on spot
3
5181-3376 5183-4493
Deactivated Vials
Clear
3
5183-4494
Clear, write-on spot
3
5183-4495
Amber, write-on spot
3
5183-4496
Crimp Top Vials with Fixed Inserts
Amber, 300 µL recommended useable volume
5188-6572
Clear, 300 µL recommended useable volume
9301-1388
Clear crimp top vials, 5181-3375
*Case includes 10 packs of 100 vials
LC Vials and Closures
Description
Unit
Part No.
6 mL Crimp Top Vials and Closures
Clear, flat bottom
100/pk 9301-1419
Crimp caps, 20 mm, PTFE/silicone septa
100/pk 9301-1425
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
19
AGILENT VIALS AND CLOSURES
Crimp Caps with 11 mm Septa
Agilent recommends using Certified crimp caps with PTFE/silicone septa to ensure seamless operation with
your Agilent autosampler. Agilent Certified crimp caps are guaranteed to work with your instrument to
reduce autosampler malfunctioning and contamination.
Magnetic crimp caps, 5188-5386
Crimp Caps with 11 mm Septa
Cap Color
Septa Type
Certified
25/pk
100/pk
500/pk
1000/pk
3
5181-1211
5183-4499
PTFE/silicone septa
3
5182-0552
5183-4500
Black Viton septa
3
5181-1212
Thin PTFE septa
3
Silver aluminum PTFE/silicone/
PTFE septa
Thin-membrane
rubber septa
5182-0871
5062-3582
PTFE/red rubber septa
5181-1210 5061-3370 5183-4498
PTFE/red rubber septa
5181-1215
Green aluminum PTFE/red rubber septa
5181-1216
Red aluminum
PTFE/red rubber septa
5181-1217
Gold aluminum
Magnetic
5188-5386
Blue aluminum
Crimp Top Vial Convenience Packs
TIPS & TOOLS
Red rubber septa have a tendency
to cause needle sticking during
sampling. Agilent recommends a
23/26 gauge needle when using
red rubber septa. Agilent Certified
crimp caps are compatible with all
needle types.
20
Vial Type
Septa Type
Cap Color
500/pk
Clear
PTFE/red rubber septa
Silver aluminum
5181-3400
Clear with write-on spot
PTFE/red rubber septa
Silver aluminum
5190-2241
Amber with write-on spot
PTFE/red rubber septa
Silver aluminum
5181-8801
AGILENT VIALS AND CLOSURES
Certified Microvolume Inserts
for Wide Opening Vials
To meet your microsampling needs, Agilent has a variety of microvolume inserts with capacities and designs
that can transform our vials from full-capacity to limited volume with one simple step. Microvolume inserts
are certified to work with all Certified vials for excellent fit with Agilent autosamplers.
Certified Microvolume Inserts for Wide Opening Vials
Maximum
Fill Volume
Recommended
Fill Volume
Unit
Glass inserts with polymer feet
and mandrel interior
320 µL
250 µL
100/pk 5181-1270*
Deactivated glass inserts with polymer feet
and mandrel interior
350 µL
250 µL
100/pk 5181-8872
Pulled-point glass inserts
350 µL
250 µL
100/pk 5183-2085
Pulled-point glass inserts
180 µL
100 µL
500/pk 9301-1387
Glass flat bottom inserts
440 µL
400 µL
500/pk 5181-3377
Deactivated glass flat bottom inserts
440 µL
400 µL
500/pk 5183-2086
Description
Part No.
Conical Inserts with Polymer Feet
Conical Glass Inserts
Flat Bottom Inserts
250 µL pulled-point glass inserts, 5183-2085
*For vortexing or mixing small volume samples, Agilent recommends using 5181-1270 because it provides a secure seal
with the cap and septum
400 µL glass flat bottom inserts, 5181-3377
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
21
AGILENT VIALS AND CLOSURES
Polypropylene Vials
Wide opening 12 x 32 mm vials are manufactured from virgin polypropylene, meeting the requirements
of 21 CFR 177.1520. Polypropylene is chemically resistant and the material of choice for sodium or heavy
metals analysis. Polypropylene vials are translucent and can be used with crimp caps.
Agilent's polypropylene vials use the purest, cleanest grade of polypropylene available, to guarantee the
lowest levels of extractables. In addition, the walls of these vials have been thickened to withstand the force
of Agilent LC and CE autosamplers. Competitor vials are not comparable.
When should I use a Polypropylene Vial?
Crimp/Snap top polypropylene vial,
250 µL, 5188-2788
The information provided below will help you to determine if polypropylene vials or silanized glass vials are
the best option for your application. As always, this information serves only as a guideline, and we always
recommend testing options before deciding on the proper vial and cap.
Polypropylene
Polypropylene vial with glass insert, 9301-0977
• Traditionally the material of choice for LC or LC/MS and CE
• Polypropylene can oxidize some biologicals
• Not recommended for light sensitive compounds
• Not compatible with a number of organic solvents
• Max temperature of ~ 175 °C
Available Sizes/Formats
Polypropylene Vials
250 µL
Crimp & Screw
Deactivated/Silanized Vials
TIPS & TOOLS
The Agilent headspace autosamplers
G1888A, and 7694A, B and E are
compatible with the flat bottom
headspace vials only. Only Agilent
vials are designed to properly fit in
the Agilent autosampler incubator.
22
2 mL
Crimp, Snap & Screw
250 µL, 400 µL
Microvolume Inserts
AGILENT VIALS AND CLOSURES
Deactivated/Silanized Vials
• Deactivation process renders surface inert
• Will not interact with metals, biologicals or proteins and will not cause shifts in pH of sample
• Compatible with a wide variety of solvents
• Available in amber for light sensitive samples
• More expensive than polypropylene
• Can withstand temperatures up to 500 °C
Agilent Polypropylene Vial Compatibility
Extraction
(<5 min)
< 1 hr
1 - 4 hr
4 - 8 hr
24 hr
Hexane
Good
Fair
Not recommended
Not recommended
Not recommended
THF
Good
Fair
Not recommended
Not recommended
Not recommended
Contact Time
MeCl2
Good
Fair
Not recommended
Not recommended
Not recommended
Toluene
Good
Fair
Not recommended
Not recommended
Not recommended
Isooctane
Good
Good
Fair
Fair
Not recommended
Acetone
Good
Good
Good
Fair
Not recommended
Ethyl acetate
Good
Good
Good
Fair
Fair
IPA
Good
Good
Good
Good
Good
Ethanol
Good
Good
Good
Good
Good
Methanol
Good
Good
Good
Good
Good
DMSO
Good
Good
Good
Good
Good
Acetonitrile
Good
Good
Good
Good
Good
Polypropylene Vials
Vial Type
Volume
Certified
Polypropylene, crimp/snap top
250 µL
3
5188-2788 9301-0978
Polypropylene, screw top
250 µL
3
5190-2242 5190-2243
Polypropylene, crimp/snap top
250 µL
Polypropylene, crimp/snap top
1 mL
100/pk
1000/pk
5190-3155
5182-0567
Polypropylene with glass insert, crimp/snap top
250 µL
9301-0977
Polypropylene with glass insert, screw top
250 µL
5188-5390
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
23
AGILENT VIALS AND CLOSURES
Headspace Vials and Closures
Beveled-neck headspace vials are available in both 10 mL and 20 mL capacities, flat or rounded bottom.
The 20 mm crimp caps provide a consistently secure seal. Agilent also offers cost-saving convenience packs
with vials, caps and septa packaged together.
• Certified for full warranted compatibility with Agilent autosamplers
• Choice of crimp or screw top vials
• Beveled top for maximum secure seal
• Two neck lengths available
• Choice of a pressure safety release cap at 45 psi
• Available in flat or rounded bottom designs
Certified Headspace Crimp Top Glass Vials
Description
Unit
Flat
Bottom
Rounded
Bottom
100/pk
5182-0838
5183-4475
5190-2238
10 mL, 23 x 46 mm
Clear
Amber
100/pk
5067-0227
Clear, graduation marks and write-on spot
100/pk
5190-2285
Amber, graduation marks and write-on spot
100/pk
5190-2287
100/pk
5182-0837
5183-4474
5190-2239
20 mL, 23 x 75 mm
Clear
Clear headspace crimp top vials with graduation
marks and write-on spot, 5190-2285
Amber headspace crimp top vials with graduation
marks and write-on spot, 5190-2288
24
Amber
100/pk
5067-0226
Clear, graduation marks and write-on spot
100/pk
5190-2286
Amber, graduation marks and write-on spot
100/pk
5190-2288
AGILENT VIALS AND CLOSURES
High Performance Septa
Agilent introduces the first septa that can withstand extreme temperatures and conditions for today's demanding headspace applications.
• Proven to withstand temperatures up to 300 °C with no degradation
• Leakproof
• Available in your choice of crimp or screw
Headspace screw top vial blank chromatogram
comparison at 300 °C with different septa
Cyclosiloxanes
1.2e+08
GC/MS conditions
Competitor C:
1e+08
Thermaseal septa claimed
can be used up to 300 °C
8e+07
Competitor B:
PTFE/silicone septa claimed
can be used up to 200 °C
6e+07
Competitor A:
PTFE/silicone septa claimed
can be used up to 200 °C
4e+07
Inlet:
Split mode w/ 10:1 ratio, 250 °C
Column:
DB-5ms Ultra Inert, 30 m x 0.25 mm,
0.25 µm, Constant flow: 2.5 mL/min
Oven:
40 °C hold 1.5 min, then 15 °C/min to 325 °C
and hold for 2.5 min, 23 min total run time
Thermal Aux/MS source/ 250 °C/230 °C/150 °C
MS guard:
MSD:
2e+07
Scan mode 25 - 550 m/z
Agilent High Performance HS Septa
0
2.00
4.00
6.00
8.00
10.00
12.00
min
14.00
16.00
18.00
20.00
22.00
Vial blank sample chromatogram at 300 °C
with Agilent High Performance HS Septa
Agilent High Performance Septa provide significant cleaner blank background at high temperature HS testing. Even with small abundance scale, the 300 °C
vial blank chromatogram with High Performance Septa only shows few siloxane peaks with very small abundance.
2e+07
100000
Headspace conditions
Septa Type: Agilent High Performance Septa, 5190-3986
Temperature: Oven/loop & valve/transfer line: 300 °C/300 °C/300 °C
50000
1e+07
2.00
2.00
4.00
4.00
6.00
6.00
8.00
8.00
10.00
10.00
12.00
min
12.00
14.00
14.00
16.00
16.00
18.00
18.00
20.00
20.00
Times:
GC cycle time: 32 min, Vial equib time: 30 min
Vial:
Fill pressure: 15 psi, Fill flow: 50 mL/min,
Loop fill ramp rate: 20 psi/min, Loop final pressure: 10 psi,
Vial Size: 20 mL, Shaking: 1
Carrier:
GC controlled
22.00
22.00
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
25
AGILENT VIALS AND CLOSURES
High Performance Septa
TIPS & TOOLS
For information on CrossLab High
Performance Septa, turn to page
41-42.
Description
Unit
Agilent Certified
Part No.
18 mm steel screw cap with
High Performance Septa
100/pk
5190-3986
5188-2753, 5188-6537, 5188-5392,
5188-6538
20 mm steel crimp cap with
High Performance Septa
100/pk
5190-3987
5182-0837, 5183-4474, 5067-0226,
5190-2239, 5182-0838, 5183-4475,
5067-0227, 5190-2238
Compatible With
20 mm Headspace Crimp Caps and Septa
Cap Color
Aluminum crimp caps, 5183-4477
Septa Type
Specifications
Certified
100/pk
10,000/pk
Silver aluminum
PTFE/silicone septa
-60 °C to 180 °C
3
5183-4477 5190-2257
Silver aluminum with
safety feature
PTFE/silicone septa
-60 °C to 180 °C
3
5183-4478
Silver aluminum
Molded PTFE/
butyl septa
-40 °C to 125 °C
3
5183-4479 5190-2258
Silver aluminum with
safety feature
Molded PTFE/
butyl septa
-40 °C to 125 °C
Silver aluminum
No septa
9301-0721
Silver aluminum with
safety feature
No septa
9301-0718
Septa only
Gray PTFE/
black butyl molded
-40 °C to 125 °C
9301-0976
Septa only
Tan PTFE/
white silicone
-60 °C to 180 °C
9301-0719 5067-0234
5183-4480
Certified Headspace Vial Convenience Packs
Headspace vial convenience kit
TIPS & TOOLS
For information on CrossLab
Headspace Vial Convenience Packs,
turn to pages 40-42.
26
Septa Type
Vial Type
Cap Color
Specifications
Unit
Part No.
Molded PTFE/
black butyl septa
Flat bottom
Silver aluminum with
safety feature
< 125 °C
100/pk
5182-0839
PTFE/silicone septa
Flat bottom
Silver aluminum with
safety feature
< 180 °C
100/pk
5182-0840
AGILENT VIALS AND CLOSURES
CombiPAL Headspace Vials and Closures
Screw top vials and caps are recommended for the tightest seal and the most reproducible headspace
results. CombiPAL headspace vials and caps are precision-threaded, making them an excellent choice for
dependability and ease-of-use. They are ideal for applications in the environmental, food and beverage,
industrial hygiene, drug analysis, and clinical chemistry industries.
CombiPAL Headspace Screw Top Vials
Description
100/pk
10 mL, 23 x 46 mm
Clear
5188-5392
Amber
5188-6538
20 mL, 23 x 75 mm
Clear
5188-2753
Amber
5188-6537
CombiPAL 18 mm Screw Top Caps with Septa
Cap Color
Septa Type
100/pk
Silver aluminum, magnetic
PTFE/silicone septa (top white, bottom blue)
5188-2759
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
27
AGILENT VIALS AND CLOSURES
Snap Top Vials and Closures
Snap top vials and caps are the simple, efficient way to a secure seal without crimping. It's as easy as
push-on, pull-off. Crimp caps can also be used with wide opening snap top vials. Note: Snap cap vials
cannot be pressurized.
• 2 mL, 12 x 32 mm
• Use with any 11 mm snap or crimp cap
• Available in unique packaging designed to reduce vial breakage
• Provides a total seal around the entire circumference of the vial crown
• Precision-formed neck improves autosampler handling
• Optional ceramic write-on spot
• Uniformly flat bottom ensures compatibility with inserts
2 mL (11 mm) Snap Top Glass Vials
Description
Snap top vials with fixed inserts
100/pk
Clear
5182-0544
5183-4504
Clear, write-on spot
5182-0546
5183-4505
Amber, write-on spot
5182-0545
5183-4506
Deactivated Vials
Clear
5183-4507
Clear, write-on spot
5183-4508
Amber, write-on spot
5183-4509
Snap Top Vials with Fixed Inserts
Clear, 300 µL useable volume
5188-6593
Amber, 300 µL useable volume
5188-6594
*Case includes 10 packs of 100 vials
28
1000/cs*
AGILENT VIALS AND CLOSURES
Polyethylene Snap Caps with 11 mm Septa
Cap Color
Septa Type
100/pk
500/pk
5182-0564
Clear
Clear PTFE/red silicone septa
5182-0550
Blue
Clear PTFE/red silicone septa
5182-3458
Green
Clear PTFE/red silicone septa
5182-3457
Red
Clear PTFE/red silicone septa
5182-3459
Clear
PTFE/silicone/PTFE septa
5182-0566
Blue
PTFE/silicone septa
5182-0541
Clear
Pre-slit PTFE/silicone septa
5183-4511
Clear
Solid polyethylene membrane septa
5182-0542
Clear
PTFE septa
5182-0540
Snap caps with septa
Snap Top Vial Convenience Packs
Vial Type
Septa Type
Cap Color
500/pk
Clear
PTFE/red rubber septa
Clear polypropylene
5182-0547
Clear with write-on spot
PTFE/red rubber septa
Clear polypropylene
5190-2240
Amber
PTFE/red rubber septa
Clear polypropylene
5182-0548
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
29
AGILENT VIALS AND CLOSURES
Specialty Vials and Closures
High Recovery Glass Vials
Wide opening, 1.5 mL vials with 30 µL reservoir are for sample concentration and injection without
transferring to microvolume inserts.
Crimp top vial, high recovery, 5182-3454
1.5 mL Wide Opening High Recovery Glass Vials
Vial Type
Unit
Screw Top
5183-2030
Clear
100/pk
Clear, silanized
100/pk
Amber
100/pk
Crimp Top
Snap Top
5182-3454
5183-4510
5183-4497
5183-2073
Micro-V Vials
• Wide opening, 1.5 mL vials with low residual volume
• Made from first hydrolytical glass Type 1
• Standard 12 x 32 mm dimension
• Compatible with 11 mm crimp closures
• Lower cost alternative to high recovery vials
Micro-V Vial, snap top, 5184-3552
Micro-V Vials
Description
30
Unit
Screw Top
Crimp Top
Snap Top
Clear
100/pk
5184-3550
5184-3551
5184-3552
Amber
100/pk
5184-3554
5184-3555
5184-3556
AGILENT VIALS AND CLOSURES
Standard Opening Screw Top Vials,
Closures and Inserts
The original, smaller opening vials with an 8-425 thread-size screw cap are available with black caps
and a variety of septa to meet the needs of your application.
• 2 mL, 12 x 32 mm, 8 mm diameter
• 8-425 thread design
• Original, standard neck size
Screw top vials, closures and inserts
2 mL Standard Opening (8 mm) Screw Top Glass Vials
Description
Unit
Part No.
Clear
100/pk 5183-4428
Amber
100/pk 5183-4429
Clear, PTFE-lined storage cap
100/pk 5183-4518
Deactivated Vials
Clear
100/pk 5183-4432
Amber
100/pk 5183-4433
Screw Caps and Septa for Standard Opening (8 mm) Vials
Cap Color
Septa Type
Unit
Black
Red PTFE/white silicone
100/pk 5183-4442
Part No.
Black
No septa
100/pk 5183-4438
Septa only
Red PTFE/white silicone/red PTFE, 8 mm
100/pk 5183-4436
Septa only
Red PTFE/white silicone, 8 mm
100/pk 5183-4437
Septa only
PTFE-coated butyl rubber
500/pk 9301-1130
8-425 screw top vials
Microvolume Inserts for Standard Opening (8 mm) Vials
Description
Unit
Part No.
Conical Inserts with Polymer Feet
150 µL glass inserts with polymer feet
100/pk 5183-2088
Conical Glass Inserts
150 µL pulled-point interior glass inserts
100/pk 5183-2089
Flat Bottom Inserts
200 µL glass flat bottom inserts
100/pk 5183-2090
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
31
AGILENT VIALS AND CLOSURES
4 mL (13 mm) Screw Top Vials and Closures
• 4 mL, 15 x 45 mm
• Precision-formed screw threads (13 x 425) for consistently secure seal
• Can be used as wash, waste, or storage vials
4 mL screw top vials
4 mL (13 mm) Screw Top Glass Vials
Description
Unit
Part No.
Clear
100/pk
5183-4448
Clear with write-on spot
100/pk
5067-0246
Amber
100/pk
5183-4450
Amber with write-on spot
100/pk
5067-0247
Caps and Septa for 4 mL (13 mm) Vials
Caps and Septa for 4 mL (13 mm) Vials
Description
Unit
Black 13 x 425 caps, PTFE/silicone septa
100/pk
Part No.
5183-4464
Black 13 x 425 open top screw caps
100/pk
5183-4461
Diffusion inserts used with black open top screw caps
12/pk
07673-40180
PTFE/natural rubber septa
144/pk
9301-1031
Red PTFE/white silicone septa
100/pk
5183-4460
White virgin PTFE septa
1000/pk
5183-4459
4 mL (13 mm) Screw Top Convenience Packs
Description
32
Unit
Part No.
Clear vials with caps (no septa)
144/pk
9301-0723
4 mL wash vials with fill markings and caps
25/pk
5182-0551
AGILENT VIALS AND CLOSURES
General Purpose Sample Storage
Vial and Caps
Agilent caps and vials are ideal for sampling and storage. Caps are lined with PTFE/silicone for excellent
sealability and chemical resistance. All caps include bonded septa that will prevent liner fallout during
shipping and sampling. Caps are manufactured of high quality materials to eliminate sample contamination.
Sample vial pack
General Purpose Sample Storage Vial Kits
Vial Size
Cap Size
4 mL, 15 x 45
13-425
12 mL, 19 x 65
22 mL, 23 x 85
40 mL, 28 x 95
15-425
20-400
24-414
Vial Type
Unit
Closed Top Open Top
Clear
100/pk
5183-4311
Amber
100/pk
5183-4321
Clear
100/pk
5183-4312
Amber
100/pk
5183-4322
Clear
100/pk
5183-4313
Amber
100/pk
5183-4323
Clear
100/pk
5183-4314
Amber
100/pk
5183-4324
5183-4331
5183-4332
5183-4333
5183-4334
Bonded Caps
Sample storage vial kit, 5183-4324
Cap
Size
Cap
Color
Cap Type
Septa Type
Unit
Closed Top Open Top
13-425
White
Polypropylene
PTFE/silicone liner
100/pk
5183-4301
5183-4305
15-425
White
Polypropylene
PTFE/silicone liner
100/pk
5183-4302
5183-4306
20-400
White
Polypropylene
PTFE/silicone liner
100/pk
5183-4303
5183-4307
24-414
White
Polypropylene
PTFE/silicone liner
100/pk
5183-4304
5183-4308
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
33
AGILENT VIALS AND CLOSURES
Crimping and Decapping Tools
Electronic Crimpers and Decappers
Designed to replace awkward and bulky manual crimping pliers, the Agilent electronic handheld crimpers
give tight, reproducible seals every time. Adjustable, slim steel jaws fit around closely spaced vials,
enabling you to crimp vials directly in crowded autosampler trays. Using the same handheld design as
the crimpers, Agilent's electronic decappers remove caps instantly and are designed for laboratories that
recycle or reuse vials.
11 mm electronic crimper, 5190-3188
• More vials crimped per battery charge – new lithium ion battery lasts three times longer
• Increased crimping speed – new model is 50% more powerful (6.4 volt battery)
• Less hand strain – lighter weight means less effort
• Improved power signal – clearly shows when battery needs recharging
• Easily used in right or left hand – display on top for easier viewing
• More efficient charging – no overheating during recharging
• Extended productivity – significantly longer motor life
Electronic Crimpers and Decappers
20 mm electronic crimper, 5190-3189
11 mm electronic decapper, 5190-3190
20 mm electronic decapper, 5190-3191
34
Description
Part No.
11 mm electronic crimper with lithium battery
5190-3188
20 mm electronic crimper with lithium battery
5190-3189
11 mm electronic decapper with lithium battery
5190-3190
20 mm electronic decapper with lithium battery
5190-3191
Replacement lithium battery for crimper and decapper
5190-3192
High Power Electronic Crimping Tool with Power Supply
5190-4061
11 mm Crimper Jaw Set for HP Electronic Crimper
5190-4062
11 mm Decapper Jaw Set for HP Electronic Crimp tool
5190-4063
20 mm Crimper Jaw Set
5190-4064
20 mm Decapper Jaw Set
5190-4065
Base for Electronic Crimping Tool
5190-4066
20 mm HP Crimping Tool and Jaw Sets Bundle
5190-4067
AGILENT VIALS AND CLOSURES
Manual Crimpers and Decappers
Agilent's ergonomic manual crimpers and decappers remove the pain and discomfort of wrist strain with a
lightweight, tailored design. Weighing 25-30% less than predecessors and eliminating sore, pinched hands,
the new design dramatically improves your experience. Extensively tested with Agilent vials for optimal fit,
and color-coded for ease-of-use, this tool is a necessity for every lab. The new crimpers are built for lasting
performance: the 11 mm crimper will cap at least 100,000 caps and the 20 mm at least 60,000 before
wear starts to impact performance.
• Comfortable, lightweight, ergonomically designed handles fit smoothly in the hand
and eliminate pinching
• Top-mounted adjustment knob shows directionality for tightening/loosening
• Adjustment knob doubles as an indicator that the crimp (or decap) is complete
• Crimpers are color-coded with blue knobs and labels, decappers with orange
• Narrow jaws provide better vertical clearance over vials
• Bottom handle motion allows for better control and enhanced stability of crimping jaw
• Sturdy construction of rugged, fiber-reinforced resin with steel reinforcement in the handles
Manual Crimpers and Decappers
Description
Part No.
Ergonomic manual crimper for 11 mm caps
5040-4667
Ergonomic manual decapper for 11 mm caps
5040-4668
Ergonomic manual crimper for 20 mm caps
5040-4669
Ergonomic manual decapper for 20 mm caps
5040-4671
Ergonomic manual crimper, 5040-4667
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
35
CROSSLAB VIALS AND CLOSURES
CrossLab Vials and Closures
Agilent CrossLab vials and closures are thoroughly tested to ensure the highest level of quality. Additionally,
CrossLab vials are designed for use in a wide range of non-Agilent GCs and LCs, including those from Bruker
(formerly Varian), Dionex (now Thermo Scientific), PerkinElmer, Shimadzu, and Thermo Scientific. They are:
• Manufactured in an ISO 9001 certified facility
• Made from First Hydrolytic Type 1 Class A or Class B borosilicate glass, which conforms to US FDA,
USP, and EU Pharmacopeia standards
• Protected by proprietary packaging with a crush barrier to reduce vial breakage
• Packaged in material that has been tested and selected for cleanliness
• Subjected to rigorous end-of-line sampling and quality control procedures to ensure all vials remain
within specifications
• Compatible with a wide variety of autosamplers regardless of make and model
36
CROSSLAB VIALS AND CLOSURES
CrossLab Vials and Closures
The table below illustrates that the Agilent CrossLab vial portfolio is compatible with a wide range of HPLC and GC autosamplers.
CrossLab Vial Compatibility
Manufacturer
Autosampler
Waters
717 Plus
8 mm Screw 9 mm Screw
Top
Top
11 mm
Crimp Top
3
Alliance 2690
3
3
CapLC
3
3
3
3
3
WISP
3
AOC14/1400
3
3
AOC-20
3
3
3
AOC 88/9
3
3
3
AOC-5000
3
3
3
3
With flange
3
3
SIL-10A, SIL-10Ai, SIL-10AxL
3
3
SIL-HT/10ADVP
3
3
3
A-200S/AS 150/800/8000
3
3
3
3
3
LC 2010
SIL-6A/6B/9A
AS 3000/TRACE GC
ASI-100
3
3
3
SURVEYOR LC
3
3
3
3
3
WPS-3000RS
3
3
3
WPS-3000SL
3
3
3
8034/8035/8100/8200
3
3
3
9095/9100
3
3
3
TriPlus
Bruker, Varian*
3
CP-8410
3
3
3
Genesis
PerkinElmer
Autosystem GC/XL/AS-2000
3
3
3
3
Clarus 500/600
3
3
3
HS16/40
Integral 4000
3
3
3
ISS-100/200
3
3
3
3
LC 600 42 vial tray
LC Plus
3
3
3
3
3
TurboMatrix 40/110
CTC Analytics
CombiPal
Magnetic
3
HSS-2B/4B
Thermo Scientific
Headspace
3
3
Acquity
Shimadzu
15 x 45 mm, 4
mL
3
3
Magnetic
*Formerly Varian systems, now Bruker products
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
37
CROSSLAB VIALS AND CLOSURES
Agilent CrossLab Vial Identification Chart
with Recommended Fill Volumes
The Agilent CrossLab vial identification chart below provides a quick reference on vial dimensions, fill volumes, and Agilent CrossLab part numbers
for a variety of vials, along with the recommended closures, for both HPLC and GC autosamplers.
Wide Opening Screw Top Vials
(9 mm)
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap*:
32 mm x 12 mm
1.7 mL
8010-0014
8010-0086
32 mm x 12 mm
1.3 mL
8010-0018
8010-0086
Wide Opening Snap Top Vials
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap*:
Narrow Opening Screw
Top Vials (8 mm)
32 mm x 12 mm
0.3 mL
8010-0008
8010-0086
32 mm x 12 mm 32 mm x 12 mm
1.3 mL
1.5 mL
8010-0028
8010-0023
8010-0108
8010-0108
40 mm x 7 mm
0.8 mL
8010-0153
8010-0516
32 mm x 12 mm
1.7 mL
8010-0001
8010-0050
32 mm x 12 mm
1.5 mL
8010-0010
8010-0061
Micro Vials
Wide Opening Crimp
Top Vials (11 mm)
32 mm x 12 mm
1.3 mL
8010-0004
8010-0050
32 mm x 12 mm
0.3 mL
8010-0006
8010-0050
Polypropylene Vials
Crimp/Snap Top
Screw Top
32 mm x 5.5 mm 32 mm x 5.5 mm
250 µL
0.1 mL
8010-0155
8010-0154
8010-0516
8010-0516
32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm
250 µL
250 µL
250 µL
0.7 mL
250 µL
8010-0160
8010-0159
8010-0161
8010-0162
8010-0158
8010-0086
8010-0086
8010-0050
8010-0050
8010-0050
Glass Insert
Glass Insert
Headspace Vials
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap*:
45 mm x 22 mm
10 mL
8010-0029
8010-0116
45 mm x 22 mm
10 mL
8010-0030
8010-0116
75 mm x 22 mm
20 mL
8010-0033
8010-0116
Specialty Vials
Dimensions:
Recommended Fill:
Part Number:
Recommended Cap*:
37 mm x 22 mm
6 mL
8010-0151
8010-0116
*Caps are available in a variety of colors
38
45 mm x 15 mm
4 mL
8010-0020
8010-0095
75 mm x 22 mm
20 mL
8010-0034
8010-0116
75 mm x 22 mm
20 mL
8010-0152
8010-0116
Inserts for Wide Opening Vials
(11 mm & 9 mm)
37 mm x 22 mm
6 mL
8010-0022
8010-0101
30 mm x 5.6 mm
250 µL
8010-0131
31 mm x 5.6 mm
250 µL
8010-0132
31 mm x 5.6 mm
400 µL
8010-0136
45 mm x 22 mm
10 mL
8010-0038
8010-0139
75 mm x 22 mm
20 mL
8010-0042
8010-0139
Inserts for Narrow Opening Vials
(8 mm)
28 mm x 4.8 mm 31 mm x 4.8 mm 31 mm x 4.8 mm
200 µL
150 µL
150 µL
8010-0126
8010-0125
8010-0124
CROSSLAB VIALS AND CLOSURES
Vial Septum Chemical Compatibility Chart
PTFE
PTFE/Silicone
PTFE/
Silicone/
PTFE*
Acetonitrile
3
3
3
3
Hydrocarbons (hexane, heptane, methane)
3
3
3
Methanol
3
3
3
Benzene
3
3
THF
3
3
Toluene
3
DMF
3
3
3
3
DMSO
3
3
3
3
Ether
3
3
3
Chlorinated Solvents (methylene chloride)
3
Alcohols (ethanol)
3
3
3
Acetic Acid
3
3
3
Acetone
3
3
3
Phenol
3
3
3
Cyclohexane
3
3
PTFE/
Red Rubber
Viton
PTFE/Butyl
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
*PTFE/silicone/PTFE has the same chemical compatibility of PTFE ONLY UNTIL PUNCTURED
Agilent provides this septa compatibility information as a guide and starting reference point. We realize that chemical compatibility can vary depending on
the concentration of the solvent, temperature, molecular weight of the solvent, and other factors. Therefore, it is always recommended that you try a variety
of septa to determine the best one for your analysis.
Vial Cap and Septum Compatibility
Thin PTFE
PTFE/
Silicone*
PTFE/
Silicone/
PTFE*
PTFE/
Red Rubber
Viton
Butyl
Up to 300 °C
for up to 1 hour
Temperature range
Up to 260 °C
Use for
multiple injections
No
Yes
Yes
No
No
No
Yes
Very economical
Economical
Most expensive
Very economical
Economical
Economical
More expensive
None
Excellent
Excellent
None
None
None
Excellent
No
Yes
Yes
No
No
No
No
Superior
chemical
inertness, short
cycle times, and
single injections
Most common
HPLC and GC
analyses, not as
resistant to
coring as P/S/P
Organic
solvents,
acetic acids;
impermeable
to gases
High temperature
headspace
applications
Price
Resistance to coring
Recommended for
storage
Best for
-40 °C to 200 °C -40 °C to 200 °C -40 °C to 90 °C -40 °C to 260 °C -50 °C to 150 °C
High Performance
Septa
Chlorosilanes,
Chlorinated
Superior
performance more economical solvents, higher
temperatures
for ultra trace option for single
injections
analysis, repeat
injections,
internal
standards
*Agilent CrossLab silicone is platinum cured (versus peroxide cured), making it more inert and less likely to interact with samples
To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly (including a vial, cap, and septum, as well as a vial insert if needed).
Please avoid mixing and matching any CrossLab vials with any other brand of closures, or any CrossLab closures with any other brand of vials.
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
39
CROSSLAB VIALS AND CLOSURES
CrossLab Headspace Vials and Closures
Headspace crimp top vials, 8010-0029
• Choice of crimp or screw top vials
• Bevelled top for maximum secure seal
• Choice of a pressure safety release cap at 45 psi
• Available in flat or rounded bottom designs
• New high performance septa designed for temperatures up to 300 °C
Headspace Crimp Top Glass Vials
Description
Unit
Flat Bottom
CrossLab
Part No.
Rounded Bottom
CrossLab
Part No.
100/pk
8010-0029
8010-0030
1000/cs
8010-0179
100/pk
8010-0031
8010-0032
100/pk
8010-0033
8010-0034
1000/cs
8010-0180
100/pk
8010-0035
10 mL Headspace Crimp Top Glass Vials
Clear
Amber, flat bottom
20 mL Headspace Crimp Top Glass Vials
Clear, flat bottom
Headspace crimp top glass vials, 8010-0033
Amber, flat bottom
8010-0036
Headspace Screw Top Glass Vials
Description
Unit
Rounded Bottom
CrossLab
Part No.
10 mL Headspace Screw Top Glass Vials
Clear, flat bottom
100/pk
8010-0038
Amber, flat bottom
100/pk
8010-0040
Clear, flat bottom
100/pk
8010-0042
Amber, flat bottom
100/pk
8010-0044
20 mL Headspace Screw Top Glass Vials
To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.
40
CROSSLAB VIALS AND CLOSURES
22 mL Headspace Crimp Top Glass Vials
Description
Unit
Agilent CrossLab
Part No.
Clear
100/pk
8010-0152
Use 20 mm crimp caps with 6 mL and 22 mL headspace vials
TIPS & TOOLS
6 mL Headspace Crimp Top Glass Vials
Description
Unit
Agilent CrossLab
Part No.
Clear
100/pk
8010-0151
Use 20 mm crimp caps with 6 mL headspace vials
NEW!
Many Agilent CrossLab vials are printed
with graduation marks and write-on
spots. Barcoding labels are also available
for regular temperature and high
temperature headspace applications.
High Performance Septa
The first septa that can withstand extreme temperatures and conditions for today's demanding
headspace applications.
• Proven to withstand temperatures up to 300 °C for one hour with minimal degradation
• Leak proof
• Available in your choice of crimp or screw
• Compatible with all common headspace solvents including DMSO, DMF, Tolulene, and Water
• Fits PerkinElmer and other headspace autosamplers
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
Headspace aluminum crimp caps
with PTFE/silicone septa, 8010-0144
41
CROSSLAB VIALS AND CLOSURES
Headspace Caps and Septa
Cap Color
Septa Type
Unit
Agilent CrossLab
Part No.
Tan PTFE/silicone
100/pk
8010-0116
Tan PTFE/silicone
1000/pk
8010-0191
Gray PTFE/butyl
100/pk
8010-0117
No septa
100/pk
8010-0120
PTFE/butyl
100/pk
8010-0143
20 mm Headspace Crimp Caps and Septa
Silver aluminum
Silver aluminum with safety feature
PTFE/silicone
100/pk
8010-0144
Silver, magnetic
Tan PTFE/silicone
100/pk
8010-0165
Bimetal, magnetic
PTFE/silicone
100/pk
8010-0420
Steel
High performance
100/pk
8010-0429*
Steel, magnetic
PTFE/silicone
100/pk
8010-0424**
Septa only
Gray PTFE/butyl
100/pk
8010-0121
Tan PTFE/silicone
100/pk
8010-0122
PTFE/white silicone
1000/pk
8010-0192
Tan PTFE/silicone
100/pk
8010-0119
PTFE/silicone
100/pk
8010-0139***
8010-0140
18 mm Headspace Screw Caps and Septa
Silver, magnetic
PTFE/butyl
100/pk
Steel
High performance
100/pk
8010-0428*
Septa only
Blue PTFE/silicone
1000/pk
8010-0418
*Recommended for high temperature applications up to 300 °C for up to one hour
**5.0 mm opening, suitable for SPME applications
***This cap is suitable for use in SPME applications
Headspace Vial Convenience Packs
Vial Type
Septa Type
Unit
Agilent CrossLab
Part No.
10 mL, crimp top, clear, flat bottom
PTFE/silicone
Silver, aluminum
100/pk
8010-0412
20 mL, crimp top, clear, flat bottom
PTFE/silicone
Silver, aluminum
100/pk
8010-0413
20 mL, screw top, clear, rounded bottom
PTFE/silicone
Silver, magnetic
100/pk
8010-0417
TIPS & TOOLS
For further information on High Performance Septa, turn to pages 25-26.
42
Cap Color
CROSSLAB VIALS AND CLOSURES
CrossLab Screw Top Vials and Closures
Combine the excellent autosampler handling of a crimp cap profile with the ease of a screw cap.
CrossLab screw caps and precision-fit septa give a secure seal with microvolume inserts.
2 mL Wide Opening (9 mm)
Screw Top Vials and Closures
• 2 mL, 12 x 32 mm, 9 mm diameter
• Available in unique packaging designed to reduce vial breakage
• Wider opening prevents syringe problems
• Unique thread design for consistently secure seal
• Precision-formed neck for optimal robotic arm handling
• Optional ceramic write-on spot with fill marks
2 mL Wide Opening (9 mm) Screw Top Glass Vials
Description
Unit
Agilent CrossLab
Part No.
Clear
100/pk
8010-0015
Clear, write-on spot
100/pk
8010-0014
Clear, 2 mL wide opening (9 mm) screw top
glass vials, 8010-0015
1000/cs 8010-0175
Amber
100/pk
8010-0017
Amber, write-on spot
100/pk
8010-0016
1000/cs 8010-0176
Screw Top Vials with Fixed Inserts
Clear, 300 µL insert volume
100/pk
8010-0008
Amber, 300 µL insert volume
100/pk
8010-0009
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
Wide opening screw top vials with write-on spot,
8010-0014
43
CROSSLAB VIALS AND CLOSURES
Screw Caps for Wide Opening (9 mm) Vials
Color
Septa Type
Unit
Agilent CrossLab
Part No.
Blue
PTFE/silicone
100/pk
8010-0086
PTFE/silicone/PTFE
100/pk
8010-0087
Pre-slit PTFE/silicone
100/pk
8010-0078
Bonded PTFE/silicone
100/pk
8010-0077
PTFE lined
100/pk
8010-0080
Open top, no septa
100/pk
8010-0079
PTFE/silicone
100/pk
8010-0088
PTFE/silicone/PTFE
100/pk
8010-0089
Pre-slit PTFE/silicone
100/pk
8010-0082
Bonded PTFE/silicone
100/pk
8010-0081
Open top, no septa
100/pk
8010-0083
100/pk
8010-0084
1000/cs
8010-0186
100/pk
8010-0085
1000/cs
8010-0187
Pre-slit PTFE/silicone
100/pk
8010-0075
Bonded PTFE/silicone
100/pk
8010-0074
Open top, no septa
100/pk
8010-0076
Red
Orange PTFE/silicone
PTFE/silicone/PTFE
Orange screw caps with PTFE/silicone septa
for wide opening (9 mm) vials, 8010-0084
Septa for Wide Opening (9 mm) Screw Caps
Septa for wide opening screw caps, 8010-0094
44
Septa Type
Color
Unit
Agilent CrossLab
Part No.
PTFE/red silicone
Ivory
100/pk
8010-0093
PTFE/white silicone/red PTFE
Red
100/pk
8010-0091
1000/cs
8010-0188
Pre-slit PTFE/white silicone
Blue
100/pk
8010-0094
PTFE/white silicone
Red
100/pk
8010-0092
CROSSLAB VIALS AND CLOSURES
2 mL Wide Opening (9 mm) Screw Top Vial Convenience Packs, 100/pk
Vial Type
Septa Type
Cap Color
Agilent CrossLab
Part No.
Clear
Pre-slit PTFE/silicone
Red
8010-0425
Clear, write-on spot
PTFE/silicone
Orange
8010-0198
Clear, write-on spot
Pre-slit PTFE/silicone
Orange
8010-0542
Clear, write-on spot, 300 µL insert volume
PTFE/silicone
Orange
8010-0545
Clear, write-on spot, 300 µL insert volume
Pre-slit PTFE/silicone
Orange
8010-0547
Amber, write-on spot
PTFE/silicone
Orange
8010-0199
Amber, write-on spot
Pre-slit PTFE/silicone
Orange
8010-0543
Amber, write-on spot, 300 µL insert volume
PTFE/silicone
Orange
8010-0546
Amber, write-on spot, 300 µL insert volume
Pre-slit PTFE/silicone
Orange
8010-0548
2 mL Standard Opening (8 mm)
Screw Top Vials and Closures
• 2 mL, 12 x 32 mm, 8 mm diameter
• 8-425 thread design
• Optional ceramic write-on spot with fill marks
2 mL Standard Opening (8 mm) Screw Top Glass Vials
Description
Unit
Agilent CrossLab
Part No.
Clear
100/pk 8010-0011
Clear, write-on spot
100/pk 8010-0010
Amber
100/pk 8010-0013
Amber, write-on spot
100/pk 8010-0012
Clear 2 mL wide opening (8 mm)
screw top glass vials, 8010-0011
2 mL Standard Opening (8 mm) Screw Top Glass Vial Convenience Packs
Agilent CrossLab
Part No.
Vial Type
Septa Type
Cap Color
Unit
Clear
PTFE/silicone
Black
100/pk 8010-0414
Clear
PTFE/butyl
Black
100/pk 8010-0426
Clear, 100 µL insert volume
PTFE/butyl
Black
100/pk 8010-0427
Amber
PTFE/silicone
Black
100/pk 8010-0415
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
45
CROSSLAB VIALS AND CLOSURES
Screw Caps for Standard Opening (8 mm) Vials
Agilent CrossLab
Part No.
Color
Septa Type
Unit
Blue
PTFE/silicone
100/pk 8010-0061
Pre-slit PTFE/silicone
100/pk 8010-0062
PTFE/silicone/PTFE
100/pk 8010-0063
PTFE/butyl
100/pk 8010-0064
Open top, no septa
100/pk 8010-0065
PTFE/silicone
100/pk 8010-0066
Pre-slit PTFE/silicone
100/pk 8010-0067
PTFE/silicone/PTFE
100/pk 8010-0068
PTFE/butyl
100/pk 8010-0069
Open top, no septa
100/pk 8010-0070
Red
Orange PTFE/silicone
Screw caps for standard opening vials, 8010-0056
Black
100/pk 8010-0056
Pre-slit PTFE/silicone
100/pk 8010-0057
PTFE/silicone/PTFE
100/pk 8010-0058
PTFE/butyl
100/pk 8010-0059
Open top, no septa
100/pk 8010-0060
PTFE/silicone
100/pk 8010-0054
Open top, no septa
100/pk 8010-0055
Flanged Caps (Compatible with Shimadzu Autosamplers)
Orange Flanged, PTFE/silicone
100/pk 8010-0141
Flanged, pre-slit PTFE/silicone
100/pk 8010-0142
Flanged, no septa
100/pk 8010-0166
Septa for Standard Opening (8 mm) Vials
46
Agilent CrossLab
Part No.
Septa Type
Unit
Red PTFE/white silicone/red PTFE
100/pk 8010-0071
Red PTFE/white silicone
100/pk 8010-0072
PTFE/butyl
500/pk 8010-0073
CROSSLAB VIALS AND CLOSURES
4 mL (13 mm) Screw Top Vials and Closures
• 4 mL, 15 x 45 mm
• Compatible with WISP 48 style autosamplers
• Precision-formed screw threads (13 x 425) for consistently secure seal
• Can be used as wash, waste, or storage vials
Black screw caps with red PTFE/silicone septa
for 4 mL (13 mm) vials, 8010-0095
4 mL (13 mm) Screw Top Glass Vials
Description
Unit
Agilent CrossLab
Part No.
Clear
100/pk
8010-0020
Amber
100/pk
8010-0021
Screw Caps for 4 mL (13 mm) Vials
Color Septa Type
Unit
Agilent CrossLab
Part No.
Black Red PTFE/silicone
100/pk
8010-0095
100/pk
8010-0096
Septa Type
Unit
Agilent CrossLab
Part No.
Red PTFE/white silicone
100/pk
8010-0098
White PTFE
100/pk
8010-0099
Pre-slit PTFE/silicone
100/pk
8010-0557
Open top, no septa
Septa for 4 mL (13 mm) Vials
4 mL (13 mm) Screw Top Vial Convenience Packs, 100/pk
Vial Type
Septa Type
Cap
Color
Agilent CrossLab
Part No.
Clear
PTFE/silicone
Black
8010-0553
Clear
Pre-slit PTFE/silicone
Black
8010-0555
Clear, 250 µL insert volume
PTFE/silicone
Black
8010-0559
Clear, 250 µL insert volume
Pre-slit PTFE/silicone
Black
8010-0561
Amber
PTFE/silicone
Black
8010-0554
Amber
Pre-slit PTFE/silicone
Black
8010-0556
Amber, 250 µL insert volume
PTFE/silicone
Black
8010-0560
Amber, 250 µL insert volume
Pre-slit PTFE/silicone
Black
8010-0562
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
47
CROSSLAB VIALS AND CLOSURES
6 mL (16 mm) Screw Top Vials and Closures
6 mL (16 mm) Screw Top Glass Vials
Screw caps for 6 mL (16 mm) vials
Agilent CrossLab
Part No.
Description
Unit
Clear
100/pk 8010-0022
Screw Caps for 6 mL (16 mm) Vials
Septa Type
Unit
Agilent CrossLab
Part No.
PTFE/silicone
100/pk 8010-0101
Pre-slit PTFE/silicone
100/pk 8010-0102
Open top, no septa
100/pk 8010-0100
10 mL (22 mm) Screw Top Vials and Closures
10 mL (22 mm) Screw Top Glass Vials
Agilent CrossLab
Part No.
Description
Unit
Clear
100/pk 8010-0563
Screw Caps for 10 mL (22 mm) Vials
Agilent CrossLab
Part No.
Septa Type
Color
Unit
No septa
Black
100/pk 8010-0565
Septa for 10 mL (22 mm) Vials
48
Agilent CrossLab
Part No.
Septa Type
Unit
PTFE/silicone
100/pk 8010-0564
CROSSLAB VIALS AND CLOSURES
CrossLab Crimp Top Vials and Closures
The wide opening crimp cap provides a larger target area for improved autosampler needle accuracy.
Select from a variety of cap colors and septa. Whatever your crimp top vial needs, Agilent has what
you are looking for.
2 mL (11 mm) Crimp Top Vials and Closures
• 2 mL, 12 x 32 mm
• Available in unique packaging designed to reduce vial breakage
• Tightly controlled crown for improved crimping
• Precision-formed neck for improved autosampler handling
• Rigorous quality assurance provides dimensional accuracy from lot to lot
• Optional ceramic write-on spot with fill marks
Crimp top glass vials with write-on spot,
8010-0001
2 mL (11 mm) Crimp Top Glass Vials
Description
Unit
Agilent CrossLab
Part No.
Clear
100/pk
8010-0002
100/pk
8010-0001
Clear, write-on spot
1000/cs 8010-0170
Amber, write-on spot
100/pk
8010-0003
1000/cs 8010-0172
Crimp Top Vials with Fixed Inserts
Clear, 300 µL insert volume
100/pk
8010-0006
Amber, 300 µL insert volume
100/pk
8010-0007
TIPS & TOOLS
Agilent offers ergonomic manual crimpers and decappers, designed to significantly reduce
hand strain. Electronic versions are also available, featuring a longer life battery designed for
quick, powerful use. For more information, please visit www.agilent.com/chem/crimper
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
49
CROSSLAB VIALS AND CLOSURES
Crimp Caps with 11 mm Septa
Cap Color
Septa Type
Unit
Agilent CrossLab
Part No.
Silver aluminum
PTFE/silicone/PTFE
100/pk
8010-0049
1000/cs
8010-0182
100/pk
8010-0050
PTFE/silicone
1000/cs
8010-0183
Pre-slit PTFE/Silicone
100/pk
8010-0582
PTFE/butyl
100/pk
8010-0051
Thin membrane rubber
25/pk
8010-0053
PTFE/red rubber
100/pk
8010-0045
1000/cs
8010-0181
PTFE/red rubber
100/pk
8010-0046
Magnetic crimp caps, 8010-0052
Blue aluminum
Green aluminum
PTFE/red rubber
100/pk
8010-0047
Red aluminum
PTFE/red rubber
100/pk
8010-0048
Gold aluminum
Magnetic
100/pk
8010-0052
2 mL (11 mm) Crimp Top Vial Convenience Packs, 100/pk
Vial Type
Septa Type
Cap Color
Agilent CrossLab
Part No.
Clear, write-on spot
PTFE/silicone
Silver aluminum
8010-0195
Clear, write-on spot, 300 µL insert volume, conical with feet
PTFE/silicone
Silver aluminum
8010-0566
Clear, write-on spot, 300 µL insert volume, conical with feet
Pre-slit PTFE/silicone
Silver aluminum
8010-0568
Amber, write-on spot
PTFE/silicone
Silver aluminum
8010-0196
Amber, write-on spot, 300 µL insert volume, conical with feet
PTFE/silicone
Silver aluminum
8010-0567
Amber, write-on spot, 300 µL insert volume, conical with feet
Pre-slit PTFE/silicone
Silver aluminum
8010-0569
TIPS & TOOLS
Red rubber septa have a tendency to cause needle sticking during sampling and are more likely to core. Agilent recommends using silicone septa
as a higher quality alternative to prevent contamination and issues related to septa coring.
50
CROSSLAB VIALS AND CLOSURES
Crimp Top Micro Vials
Agilent CrossLab offers a selection of crimp top micro vials designed for a variety of autosamplers,
including HTS and HTC PAL systems, to cope with today's high-throughput LC/MS demands. Additionally,
Agilent CrossLab crimp top micro vials work seamlessly with CombiPAL and GC PAL magnetic needle guides
and barcode readers.
Crimp Top Micro Vials
Description
Volume
Unit
Agilent CrossLab
Part No.
Amber, flat bottom
0.8 mL
1000/pk 8010-0153
Clear, tapered bottom
0.1 mL
500/pk
8010-0154
Clear, round bottom
0.3 mL
500/pk
8010-0155
Amber, flat bottom crimp top micro vials,
8010-0153
CrossLab Snap Top Vials and Closures
Snap top vials and caps are the simple, efficient way to a secure seal without crimping. It's as easy as
push-on, pull-off. Crimp caps can also be used with wide opening snap top vials.
Note: Snap cap vials cannot be pressurized.
2 mL (11 mm) Snap Top Vials and Closures
• 2 mL, 12 x 32 mm
• Use with any 11 mm snap or crimp cap
• Available in unique packaging designed to reduce vial breakage
• Precision-formed neck improves autosampler handling
• Optional ceramic write-on spot
2 mL (11 mm) Snap Top Glass Vials
Description
Unit
Agilent CrossLab
Part No.
Clear
100/pk
8010-0024
Clear, write-on spot
100/pk
8010-0023
Amber
100/pk
8010-0026
Amber, write-on spot
100/pk
8010-0025
1000/cs 8010-0177
Snap top vials with write-on spot, 8010-0025
1000/cs 8010-0178
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
51
CROSSLAB VIALS AND CLOSURES
Snap Caps with 11 mm Septa
Cap Color
Septa Type
Unit
Agilent CrossLab
Part No.
Clear
PTFE/red silicone
100/pk
8010-0104
PTFE/silicone/PTFE
100/pk
8010-0105
Pre-slit PTFE/white silicone
100/pk
8010-0106
Snap caps with 11 mm red silicone septa,
8010-0103
Clear polyethylene membrane
100/pk
8010-0107
Blue
PTFE/red silicone
100/pk
8010-0108
PTFE/white silicone
100/pk
8010-0112
Green
PTFE/red silicone
100/pk
8010-0109
Orange
PTFE/red silicone
100/pk
8010-0103
PTFE/red silicone
1000/cs 8010-0189
PTFE/white silicone
100/pk
Pre-slit PTFE/white silicone
1000/cs 8010-0190
Pre-slit PTFE/white silicone
100/pk
8010-0113
PTFE/red silicone
100/pk
8010-0110
100/pk
8010-0115
Red
Polyurethane
8010-0111
2 mL (11 mm) Snap Top Vial Convenience Packs
52
Agilent CrossLab
Part No.
Vial Type
Septa Type
Cap Color
Unit
Clear, write-on spot
PTFE/silicone
Orange
100/pk 8010-0200
Amber, write-on spot
PTFE/silicone
Orange
100/pk 8010-0411
CROSSLAB VIALS AND CLOSURES
Snap Top Solvent Vial Convenience Packs
Snap Top Solvent Vial Convenience Packs
Cap Color Unit
Agilent
CrossLab
Part No.
Clear
100/pk
8010-0416
Clear
100/pk
8010-0422
Cap Color Septa Type
Unit
Agilent
CrossLab
Part No.
Clear
50/pk
8010-0423
Septa Type
Unit
Agilent
CrossLab
Part No.
Red rubber
100/pk
8010-0430
Vial Type
Septa Type
5 mL Snap Top Solvent Vial Convenience Pack
Clear
PTFE/silicone
10 mL Snap Top Solvent Vial Convenience Pack
Clear
Red PTFE/white silicone
Snap Cap for 5 mL and 10 mL Solvent Vials
PTFE/silicone
19 mm Septa for 5 mL and 10 mL Snap Caps
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
53
CROSSLAB VIALS AND CLOSURES
CrossLab Polypropylene Vials
Wide opening 12 x 32 mm vials are manufactured from virgin polypropylene, meeting the requirements
of 21 CFR 177.1520. Polypropylene vials are translucent and can be used with crimp or snap caps.
CrossLab polypropylene vial, crimp/snap top,
8010-0158
Polypropylene Vials
Description
Recommended Max Fill
Fill Volume
Volume
Unit
Agilent
CrossLab
Part No.
Polypropylene, crimp/snap top
250 µL
440 µL
100/pk
8010-0158
Polypropylene, crimp/snap top
250 µL
440 µL
1000/cs
8010-0193
Polypropylene, crimp/snap top
0.7 mL
1 mL
100/pk
8010-0159
Polypropylene, screw top
250 µL
440 µL
100/pk
8010-0161
Polypropylene, screw top
250 µL
440 µL
1000/cs
8010-0194
Polypropylene with glass insert, crimp/snap top
250 µL
350 µL
100/pk
8010-0160
Polypropylene with glass insert, screw top
250 µL
350 µL
100/pk
8010-0162
Polypropylene vial with glass insert, 8010-0160
CrossLab Micro-V Vials
• Wide opening, 1.5 mL vials with low residual volume
• Made from first hydrolytic glass Type 1
• Standard 12 x 32 mm dimension
• Compatible with 11 mm crimp closures
Clear, crimp top Micro-V vial, 8010-0004
TIPS & TOOLS
For economical and effective
microsampling, choose the polypropylene
vial with molded glass flanged insert. Its
polypropylene body has a glass flanged
insert molded to the inside, so the sample
comes in contact only with the high quality
glass insert and the septum.
54
Micro-V Vials
Description
Unit
Screw Top Crimp Top Snap Top
Clear, screw top
100/pk 8010-0018
8010-0004 8010-0027
Amber
100/pk 8010-0019
8010-0005 8010-0028
CROSSLAB VIALS AND CLOSURES
CrossLab Microvolume Inserts
To meet your microsampling needs, Agilent offers a variety of microvolume inserts with capacities
and designs that can transform your vials from full-capacity to limited volume with one simple step.
Microvolume Inserts for 8 mm Screw Top Vials
Microvolume inserts
Description
Max
Recommended
Fill Volume Fill Volume
Agilent CrossLab
Part No.
Unit
Glass conical insert with polymer feet
200 µL
150 µL
100/pk 8010-0124
Glass pulled-point insert
200 µL
150 µL
100/pk 8010-0125
Flat bottom insert
250 µL
200 µL
100/pk 8010-0126
Microvolume Inserts for 11 mm Crimp Top or 9 mm Screw Top Vials
Description
Max
Recommended
Fill Volume Fill Volume
Unit
Agilent CrossLab
Part No.
Conical insert with polymer feet
350 µL
250 µL
100/pk 8010-0131
Pulled-point insert
350 µL
250 µL
100/pk 8010-0132
Flat bottom insert
440 µL
400 µL
500/pk 8010-0136
250 µL conical insert with
polymer feet, 8010-0131
Microvolume Inserts for 4 mL (13 mm) Screw Top Vials
Description
Max
Recommended
Fill Volume Fill Volume
Unit
Pulled-point insert with flange
350 µL
100/pk 8010-0558
250 µL
Agilent CrossLab
Part No.
250 µL pulled-point glass insert, 8010-0132
400 µL flat bottom glass insert, 8010-0136
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
55
CROSSLAB VIALS AND CLOSURES
CrossLab Well Plates and Sealing Mats
Choose the cleanest well plates and
sealing mats for your autosamplers
Advantages of Agilent CrossLab
well plates:
Advantages of Agilent CrossLab
sealing mats:
• Made from polypropylene
• Free from RNase, DNase, Endotoxins, and human DNA
• Chemically resistant to common solvents
• Autoclavable (121 °C/20 min)
• Alpha-numeric grid
• Compatible with pipetting workstations and multi-channel pipettes
• Raised rims are available with 0.5 mL and 1.0 mL deep well plates
• Protect well contents during storage
• Free from RNase, DNase, Endotoxins, and human DNA
• Highly flexible for a tight seal and exact fit
• Insets in every well eliminate the need for glue during connection
• Pierceable with pipette tips (0.5 mL and 1.0 mL sealing mats)
• Prevent solvent evaporation
• Made from thermoplastic elastomer (TPE)
for efficient sealing and a reduced risk of cross-contamination
during rigorous vortexing
or ethylene-vinyl acetate (EVA)
• Compatible with common solvents
• Available in 96- or 384-well plate format
• 96-well plates range from 0.2 mL to 2 mL
• 384-well plates available in 0.1 mL and 0.25 mL
• Stackable
Cleanliness of well plates and sealing mats: Agilent CrossLab vs. the competition
Blank in competitor A 1.0 mL 96-well plate
20000000
Total Ion Current (TIC)
Blank in competitor B 1.0 mL 96-well plate with matching sealing mat
The chemical extraction
experiments demonstrate
the superior cleanliness
of the Agilent CrossLab
well plates and sealing
mats compared to the
competition, making them
ideal for LC/MS applications.
15000000
Blank in Agilent CrossLab 1.0 mL 96-well plate with matching sealing mat
10000000
Reagent blank
5000000
System blank
0
0
1
2
3
4
5
6
7
8
LC/MS ESI positive chromatogram comparison. Reagent blank: 1:1 Acetonitrile/H2O with 0.1% formic acid
56
9
min
CROSSLAB VIALS AND CLOSURES
CrossLab Well Plates and Sealing Mats
Agilent CrossLab offers a range of polypropylene 96-well or 384-well plates with a variety of sealing options for collection of samples, storage,
and use in autosamplers.
Well Plates
Description
Well Volume
(mL)
Plate Height
(mm)
Material
Well Depth
(mm)
Well Shape
Bottom Shape
Unit
Agilent
CrossLab
Part No.
96-well plate
0.2
Polypropylene
20.9
20.9
Round
Conical
50/pk
8010-0532
96-well plate
0.5
Polypropylene
26.5
21.6
Round
Round
56/pk
8010-0533
96-well plate
1.0
Polypropylene
39.1
37.1
Round
Round
32/pk
8010-0534
96-well plate
2.0
Polypropylene
44
41.85
Round
Round
32/pk
8010-0536
384-well plate
0.1
Polypropylene
14.4
11.7
Square
Round
120/pk 8010-0538
384-well plate
0.25
Polypropylene
22
19.5
Square
Round
60/pk
8010-0539
Description
Unit
Agilent
CrossLab
Part No.
Sealing mat for 0.2 mL 96-well plates, Thermoplastic Elastomers (TPE)
5/pk
8010-0577
Sealing Mats and Accessories
Sealing mat for 0.5 mL and 1.0 mL 96-well plates, Thermoplastic Elastomers (TPE)
50/pk
8010-0535
Sealing mat for 2 mL 96-well plate, Ethylene Vinyl Acetate (EVA)
50/pk
8010-0537
Sealing tape for 384-well plate, polyethylene
100/pk 8010-0540
Sealing foil, self adhesive, high transparency, for all plates, Polyethylene terepthalate (PET)
100/pk 8010-0541
Sealing foil, self adhesive, for all plates, Polypropylene
100/pk 8010-0578
96-well plate, 8010-0534
96-well plate with removable sealing mat,
8010-0534
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
Sealing mat for 2 mL 96-well plate,
(EVA), 8010-0537
57
CROSSLAB VIALS AND CLOSURES
CrossLab Vials Cross Reference List
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the CrossLab products are
viable alternatives to OEM products. CrossLab products are compatibile with the corresponding OEM instruments, although in some cases, the CrossLab
products may have slightly different designs as compared to the OEM counterparts.
CrossLab Vials for
Bruker/Varian
CrossLab Vials for
Bruker/Varian
Similar to
Bruker/Varian
Part No.
Agilent
CrossLab
Part No.
Similar to
Bruker/Varian
Part No.
Agilent
CrossLab
Part No.
Similar to
Bruker/Varian
Part No.
Agilent
CrossLab
Part No.
392611525
8010-0195
392611659
8010-0084
8010-0414
392611659
8010-0086
190010209
392620510
8010-0093
392611530
392611549
8010-0198
392611659
8010-0088
392620514
8010-0008
392611550
8010-0199
392611667
8010-0159
392620517
8010-0170
392611675
392612021
MLA202100
8010-0034
392620526
8010-0032
392611857
8010-0151
392611593
8010-0125
190010204
392611594
392620538
8010-0131
392611596
392611636
8010-0132
392611607
8010-0143
392610003
392611858
ROK7382420
392611607
8010-0413
392611859
392611613
8010-0142
392611871
8010-0108
CP10277
8010-0020
392611613
8010-0412
8010-0416
8010-0050
CP741315
CP913323
8010-0038
392611631
392611632
8010-0051
8010-0002
CP912446
CP913077
8010-0418
390886500
392611634
392611970
392611974
392611975
392611980
392611981
392611982
392611639
392620550
CP10271
8010-0011
392611640
8010-0013
392611641
8010-0056
392611641
8010-0061
392611645
8010-0064
392620528
8010-0036
1600069800
8010-0070
390614901
6900016900
R005486RT1
8010-0072
8010-0116
CP10204
8010-0029
8010-0121
CP10205
8010-0033
392620104
8010-0040
392620202
8010-0042
392620204
8010-0044
392620302
392620304
8010-0139
392620306
8010-0140
392620401
392620403
8010-0417
8010-0175
8010-0092
392611641
8010-0066
392611645
8010-0059
392611645
8010-0069
392611646
392611653
8010-0015
392620500
CPLC40111B
CPLC40111R
392611654
8010-0017
190010209
392620510
(Continued)
58
CrossLab Vials for
Bruker/Varian
(Continued)
CP959464
8010-0420
CP959485
8010-0155
39260500
CPLC40111B
CPLC40111R
8010-0014
CPLCL07CPVA
8010-0172
CPLCL11ACBST144
8010-0183
MLA110040M
8010-0152
392611860
392612017
MLA2000051ML
8010-0165
MLA21000
8010-0030
R000548SCY
8010-0160
CROSSLAB VIALS AND CLOSURES
CrossLab Vials for
PerkinElmer
CrossLab Vials for Shimadzu
CrossLab Vials for
Thermo Scientific
Similar to
Shimadzu
Part No.
Agilent
CrossLab
Part No.
038-00165-06
8010-0011
220-90384-00
8010-0055
8010-0144
220-90393-00
8010-0020
8010-0122
220-90394-00
8010-0096
B4000025
8010-0121
220-91521-14
8010-0095
N6356478
8010-0030
220-94562-00
8010-0412
N6356479
8010-0038
220-94563-00
8010-0413
N9300500
8010-0195
220-94796-01
8010-0042
N9300700
8010-0198
220-94796-02
8010-0119
N9301385
8010-0002
220-94796-07
8010-0038
N9302680
8010-0003
221-34271-92
8010-0054
N9302684
8010-0047
221-34271-92
8010-0056
N9302685
8010-0048
221-34271-92
8010-0072
N9302686
8010-0046
228-21290-91
8010-0098
N9303416
8010-0106
228-45450-91
8010-0198
60180-526
8010-0046
N9303416
8010-0113
228-45452-91
8010-0199
60180-560
8010-0012
N9303417
8010-0105
8010-0112
N9303418
8010-0024
N9303419
8010-0104
60180-561
C4000-2W
2SVW(A)
11 09 0520
8010-0016
N9303417
N9303419
8010-0111
Similar to
PerkinElmer
Part No.
Agilent
CrossLab
Part No.
B0104239
8010-0143
B0104241
B4000022
N9303441
8010-0055
N9303442
8010-0073
N9303992
8010-0413
N9306015
8010-0051
N9306052
8010-0054
N9306075
8010-0042
N9306077
8010-0119
N9306079
8010-0034
N9306201
8010-0015
N9306202
8010-0086
N9306207
8010-0023
N9306208
8010-0025
N9306220
8010-0017
N9306228
8010-0050
N9306229
8010-0049
N9306240
8010-0152
N9306247
8010-0020
CrossLab Vials for
Thermo Scientific
Similar to
Thermo Scientific
Part No.
Agilent
CrossLab
Part No.
60180-507
8010-0008
10-800-247
8010-0038
14-824-365
8010-0042
60180-502
C4011-1W
2-CV
11 09 0476
8010-0001
60180-504
10-800-246
8010-0030
60180-505
14-824-360
8010-0032
60180-506
8010-0034
60180-507
8010-0008
Similar to
Thermo Scientific
Part No.
Agilent
CrossLab
Part No.
60180-510
C4015-1
4-SV
13 09 0222
8010-0020
60180-511
8010-0116
60180-513
8010-0117
60180-514
8010-0055
60180-514
8010-0060
60180-514
8010-0065
60180-514
8010-0070
60180-515
8010-0061
60180-516
8010-0086
60180-521
60180-522
8010-0122
60180-562
8010-0066
60180-597
8010-0195
60180-599
8010-0198
60180-713
8010-0112
C4013-98Y
8010-0166
CrossLab Vials for Waters
60180-508
8010-0010
60180-509
C4000-1W
2SVW
11 09 0519
8010-0014
(Continued)
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
Similar to
Waters
Part No.
Agilent
CrossLab
Part No.
186000842
8010-0557
186001420
8010-0563
186001421
8010-0565
186001422
8010-0564
186000307C
8010-0542
186000838C
8010-0553
186000839C
8010-0555
186000847C
8010-0543
186001133C
8010-0554
186001134C
8010-0556
WAT025053C
8010-0575
WAT025054C
8010-0574
59
AGiLENT SyriNGES
Agilent Syringes
With a broad selection of syringes for manual and auto injectors, Agilent has what you need for accurate
and effective sampling.
Whether you need an autosampler or manual syringe, there are two keys to choosing the right syringe –
identifying your sample type and establishing the smallest volume to be dispensed or injected. Agilent offers
two varieties of syringes.
PTFE-Tipped Syringes for Gases and Liquids
PTFE-tipped syringes have a precision-machined plunger tip that forms a tight seal and enables the tip to
wipe the barrel’s interior free of sample during operation. This feature is particularly useful for viscous or
heterogeneous samples, because it reduces deposits that can cause the plunger to freeze. Replacement
plunger assemblies are available for most PTFE-tipped syringes.
Fitted Plunger Syringes for Liquids
Fitted plunger syringes feature a stainless steel plunger that is meticulously hand-fitted to its matching glass
barrel, creating a liquid-tight seal. These syringes are ideal for homogenous samples that are not prone to
precipitation or bonding with glass. Note: plungers cannot be interchanged or replaced if damaged.
Syringe Features
Removable Needle
ALS Syringe
Needle
Termination
Volume Markings
Fixed Needle
Manual Syringe
Plunger Tip (PTFE)
Reference drawing (not to scale)
60
Barrel
Flange
Plunger
AGiLENT SyriNGES
Needle Gauge
Needle gauge is the thickness of the needle. The gauge depends on the injector. When selecting a needle
gauge, it is important to keep in mind the volume of the syringe and the dead volume of the needle. Refer
to the chart below to choose a needle gauge with an appropriate dimension before selecting a needle.
Typical Needle Gauge Dimensions
OD
Gauge
mm
iD
inches
mm
inches
22
0.71
0.028
0.41
0.016
23s
0.635
0.025
0.11
0.0045
25
0.50
0.020
0.20
0.008
26s
0.47
0.0184
0.11
0.0045
Tapered Dual Gauge 23-26 or 23s-26s (0.64-0.47 mm)
Durability of a 23-gauge
Versatility of a 26-gauge for split/splitless and on-column injection
Single Gauge 22 (0.71 mm)
HPLC valves
Pipetting liquids
Single Gauge 23 or 23s (0.64 mm)
Merlin Microseal septa
Packed column injector ports
Split/splitless injector ports
Single Gauge 26 or 26s (0.47 mm)
Packed column injector ports
Split/splitless injector ports
Note: Needles with an 'S' following the gauge are more durable, with a thicker needle wall and smaller id bore.
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
61
AGiLENT SyriNGES
Needle Termination
Needle terminations are available in fixed or removable, with various tip styles:
• Fixed (cemented) – Economical, reproducible injections for autosamplers
• removable needle – One syringe fixed – many methods, simplicity of fixed needle,
but needle can be replaced if damaged or clogged
• Luer tip – Easy, fast needle replacement, syringe filter or pump priming, Luer tip is ground
glass suitable for mounting chromatographic or PTFE needles, syringes can be autoclaved
(without plunger or needle)
• Luer Lok – Security of a locked needle, syringe filter or pump priming, PTFE, male Luer taper with
nickel-plated brass locking hub for use with KEL-F or metal hub needles and universal connectors
Needle Tip Design
62
hP Tip
(also referred to as
cone or Point Style AS)
Bevel Tip
(Point Style 2, BV)
Lc Tip
(Point Style 3)
Side hole
(Point Style 5)
Proprietary design required
for Agilent autosamplers
for optimal performance
and reliability by reducing
septum coring.
General purpose; excellent
choice for transferring liquids
from ampoules or vials.
For manual GC injections, a
beveled tip is preferred for
optimum septum penetration
and to prevent septum coring.
For HPLC injections and sample
pipetting, the blunt tip style 3
is preferred. The blunt tip has
chamfered and polished edges
that eliminate damage to the
valve's rotor seal and stator
face. This style can also be
used for pipetting liquids.
Recommended for
thin gauged septa or
large volume injections.
AGiLENT SyriNGES
Autosampler Syringes
Premium autosampler syringes optimize system productivity
and ensure precise sample handling
Agilent Blue Line Autosampler Syringes
for 7693A ALS
Agilent blue line autosampler syringes are specifically designed to support the higher productivity features
of the 7693A ALS, while increasing plunger life and reducing costly downtime. Backed by over 40 years of
chromatography experience, these meticulously crafted syringes offer:
• Wider range of volumes including exclusive 250 and 500 µL syringes for sample
enhancement with the new 7693A
• Precise match with your autosampler’s stroking mechanism, resulting in more accurate
volume delivered
• Smooth needle that reduces septum coring and keeps your system working at its full potential
• Choice of PTFE-tipped or metal fitted plunger to meet application needs
• Easy-open, environmentally friendly packaging
• Certified compliance with strict Agilent specifications
Blue line autosampler syringe shown in
7693A ALS, G4513-80204
TiPS & TOOLS
Order your free GC troubleshooting and GC column installation posters
at www.agilent.com/chem/Gcposteroffer
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
63
AGiLENT SyriNGES
Blue Line Autosampler Syringes
with Fitted Plungers
Fitted plunger syringes are recommended for homogeneous liquid samples. Each fitted syringe is individually
matched with the plunger for precision injection. Plungers are not interchangeable or replaceable.
Blue Line Autosampler Syringes with Fitted Plungers
Blue line autosampler syringe, G4513-80205
Volume
(µL)
Description
1
Plunger in needle, fixed
unit
Needle Gauge/
Length (mm)/Tip
Part No.
23/42/cone tipped
G4513-80229
Replacement needle/plunger
2
G4513-80240
Plunger in needle, fixed
23/42/cone tipped
Replacement needle/plunger
5
Straight, fixed
Straight, fixed
23/42/HP
G4513-80213
23/42/HP
G4513-80205
26s/42/HP
G4513-80226
26s/42/HP
G4513-80212
23-26s/42/HP
G4513-80206
23-26s/42/HP
G4513-80201
23/42/HP
G4513-80234
23/42/HP
G4513-80236
23-26s/42/HP
G4513-80224
3/pk
23-26/42/HP
G4513-80225
23/42/HP
G4513-80209
6/pk
23/42/HP
G4513-80202
26s/42/HP
G4513-80216
6/pk
26s/42/HP
G4513-80211
23-26s/42/HP
G4513-80204
6/pk
23-26s/42/HP
G4513-80200
23/42/HP
G4513-80235
3/pk
23/42/HP
G4513-80236
23-26s/42/HP
G4513-80218
6/pk
Straight, fixed
Straight, fixed
6/pk
Tapered, fixed
Tapered, fixed
6/pk
Straight, removable
Replacement needle
3/pk
Tapered, removable
Replacement needle
10
Straight, fixed
Straight, fixed
Straight, fixed
Straight, fixed
Tapered, fixed
Tapered, fixed
Straight, removable
Replacement needle
Blue line autosampler syringe, G4513-80204
Removable
Replacement needle
64
G4513-80215
G4513-80239
23-26/42/HP
G4513-80225
25
Tapered, fixed
3/pk
23-26/42/HP
G4513-80242
50
Tapered, fixed
23-26/42/HP
G4513-80244
100
Tapered, fixed
23-26/42/HP
G4513-80243
AGiLENT SyriNGES
Blue Line Autosampler Syringes
with PTFE-Tipped Plungers
Suitable for gas and liquid samples, the PTFE tip of the plunger creates a tight seal between the plunger
and glass, helping to reduce carry-over and increase syringe lifetime. Replacement plungers are available.
Blue Line Autosampler Syringes with PTFE-Tipped Plungers
Volume
(µL)
Description
10
Straight, fixed
unit
Straight, fixed
6/pk
Tapered, fixed
Needle Gauge/
Length (mm)/Tip
Part No.
23/42/HP
G4513-80220
23/42/HP
G4513-80210
23-26/42/HP
G4513-80203*
Replacement plunger for fixed needle
Tapered, fixed
G4513-80227
6/pk
Straight, removable
Replacement needle
3/pk
Tapered, removable
Replacement needle
25
50
100
3/pk
23-26s/42/HP
G4513-80208
23/42/HP
G4513-80219
23/42/HP
G4513-80236
23-26/42/HP
G4513-80233
23-26/42/HP
G4513-80225
Straight, fixed
23/42/HP
G4513-80228
Tapered, fixed
23-26/42/HP
G4513-80241
Straight, fixed
23/42/HP
G4513-80221
Tapered, fixed
23-26/42/HP
G4513-80223
Tapered, Fixed
23-26s/42/HP
G4513-80222
Needles, replacement, G4513-80236
*Included in 7693A shipments
Advanced Sample Enhancement Autosampler
Syringes with PTFE-Tipped Plungers
Used with the 7693A optional Enhanced Sample Handling Syringe Carriage, these syringes can eliminate
analyst-to-analyst variability and reduce re-work in sample preparation, such as dilution and internal
standard addition.
Advanced Sample Enhancement Autosampler Syringes
with PTFE-Tipped Plungers
Volume (µL) Description
Needle Gauge/
Length (mm)/Tip
Part No.
250
Fixed, advanced sample enhancement
23/42/HP
G4513-60560
500
Fixed, advanced sample enhancement
23/42/HP
G4513-60561
Blue line autosampler syringe,
G4513-60560
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
65
AGiLENT SyriNGES
Gold Standard Autosampler Syringes
Use one needle and get the benefits of two. The upper portion of the tapered needle offers the strength
of a 23-gauge needle, while the lower portion at 26s-gauge allows use with split/splitless or on-column
injections with 0.53 mm id columns. All standard plungers are stainless steel.
Tapered Needle, 23-26s Gauge Autosampler Syringes
Needle
Gauge/Length
unit (mm)/Tip
Volume
(µL)
Description
5
Tapered, fixed
23-26s/42/HP
5181-1273
Tapered, fixed
6/pk 23-26s/42/HP
5181-8810
23-26s/42/HP
5182-0835
Tapered, fixed
23-26s/42/HP
5181-1267
Tapered, fixed
6/pk 23-26s/42/HP
5181-3360
23-26s/42/HP
5181-3321
Tapered, fixed, PTFE-tipped plunger
23-26s/42/HP
5181-3354
Tapered, fixed, PTFE-tipped plunger
6/pk 23-26s/42/HP
5181-3361
Tapered, removable
Replacement needle for 5 µL syringe
10
3/pk
Tapered, removable
Replacement needle for 10 µL syringe
5182-0832
3/pk
5181-3319
Replacement plunger with PTFE tip
for fixed needle 10 µL syringe
Tapered, removable
5181-3365
23-26s/42/HP
Replacement plunger with PTFE tip
for removable needle 10 µL syringe
66
Part No.
5181-3356
5181-3358
50
Tapered, fixed, PTFE-tipped plunger
23-26s/42/HP
5183-0314
100
Tapered, fixed, PTFE-tipped plunger
23-26s/42/HP
5183-2042
AGiLENT SyriNGES
Straight Needle, 23 and 26s Gauge Autosampler Syringes
Volume
(µL)
Description
Needle Gauge/
Length (mm)/Tip
1
Part No.
Cone-tipped
23/42/HP
5188-5246
1
Replacement needle/plunger for 1.0 µL syringe
23/42/HP
5188-5370
0.5
Replacement needle/plunger for 0.5 µL syringe
23-26/42/HP
5190-3193
2
Cone-tipped
23/42/HP
5188-5247
Replacement needle/plunger for 2.0 µL syringe
23/42/HP
5188-5371
26s/42/HP
9301-0891
26s/42/HP
5183-4728
23/42/HP
9301-0892
23/42/HP
5182-0875
23/42/HP
5182-0834
5
unit
Straight, fixed
Straight, fixed
6/pk
Straight, fixed
Straight, fixed
6/pk
Straight, removable
Replacement needle for 5 µL syringe
10
3/pk
Straight, fixed
5182-0830
26s/42/HP
Straight, fixed
6/pk
Straight, fixed
5183-4729
23/42/HP
9301-0713
6/pk
23/42/HP
9301-0725
23/42/HP
5181-8809
6/pk
23/42/HP
5183-4730
Straight, fixed, PTFE-tipped plunger
Straight, fixed, PTFE-tipped plunger
Replacement plunger for 10 µL fixed needle syringe
5181-8808
Straight, removable
Straight, removable, PTFE-tipped plunger
Replacement needle for 10 µL syringe
23/42/HP
5181-8806
23/42/HP
5181-8813
3/pk
5181-8811
Replacement plunger with PTFE tip
for removable needle 10 µL syringe
25
Straight, fixed, PTFE-tipped plunger
9301-0714
26s/42/HP
Straight, fixed
Autosampler Syringes
5181-3358
23/42/HP
5183-0316
50
Straight, fixed, PTFE-tipped plunger
23/42/HP
5183-0318
100
Straight, fixed, PTFE-tipped plunger
23/42/HP
5183-2058
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
67
AGiLENT SyriNGES
7673/7683 On-column Autosampler Syringes
Agilent 7673/7683 on-column syringes with needle diameter for columns ranging from 0.25 mm
to 0.53 mm are specifically designed for the 7673/7683 Autosampler.
7673/7683 On-column Autosampler Syringes
Volume (µL) Description
5
unit
Removable needle, syringe only
Part No.
5182-0836
Stainless steel needle for 0.53 mm column
3/pk
5182-0832
Stainless steel needle for 0.32 mm column
3/pk
5182-0831
Stainless steel needle for 0.25 mm column
3/pk
5182-0833
Plunger button
10/pk
5181-8866
hP 7670/71/72 Autosampler Syringes
This syringe has a long needle and regular plunger button for compatibility with HP 7670/71/72
autosamplers. Available with a fixed or removable needle.
hP 7670/71/72 Autosampler Syringes
Volume (µL) Description
Autosampler syringe, 10 µL, straight, RN,
5182-9626
68
Needle
Part No.
1
Straight, removable
23/56/2
5182-9622
10
Straight, fixed
23/50/HP
5182-9734
Straight, removable
23/50/HP
5182-9626
Straight, fixed, PTFE-tipped plunger
23/50/HP
5182-9799
AGiLENT SyriNGES
Manual Syringes
Agilent color-coded manual syringes allow you to determine syringe volume with one quick glance,
so you can more efficiently perform manual dilution, extraction, and sample prep. They also give you
the advantages of:
• Improved scale readability with a new vertical syringe scale orientation for more intuitive use
• A wide selection of volumes, making Agilent your "one-stop" resource for all of your sample
manipulation needs
• Accuracy within ±1% of nominal volume, and precision within 1%, measured at 80% of
total scale volume
• Earth-friendly cardboard and plastic packaging that could be recycled to help reduce landfill waste
• A Certificate of Conformance to ensure the highest quality construction and performance, available
for viewing and printing anytime
• Lot-traceable for accurate identification
Of course, all Agilent syringes are backed by over 40 years of chromatography expertise, industry-leading
technical support, and a 90-day warranty from the date of shipment.
Manual Syringes color code chart
0.5 µL
1.0 µL
2.0 µL
5.0 µL
10 µL
1.0 mL
25 µL
2.5 mL
50 µL
5.0 mL
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
100 µL
10.0 mL
250 µL
25.0 mL
500 µL
50.0 mL
69
AGiLENT SyriNGES
Manual Syringes with Fitted Plunger, Fixed and removable Needle, 0.5 to 5 µL
Volume
(µL)
Description
0.5
Plunger in needle, removable
unit Needle
23/70 mm/cone tip
Replacement needle and plunger kit
for 0.5 µL syringe
5190-1461
Plunger in needle, removable
23/70 mm/bevel tip
Replacement needle and plunger kit
for 0.5 µL syringe
1.0
Plunger in needle, removable
26/70 mm/cone tip
26/70 mm/bevel tip
Replacement needle and plunger kit
for 1.0 µL syringe
Plunger in needle, removable
23/70 mm/cone tip
23/70 mm/bevel tip
Replacement needle and plunger kit
for 1.0 µL syringe
5190-1465
5190-1469
Plunger in needle, removable
23/70 mm/cone tip
Replacement needle and plunger kit
for 2.0 µL syringe
5190-1471
5190-1473
Plunger in needle, removable
26/70 mm/bevel tip
Replacement needle and plunger kit
for 2.0 µL syringe
5190-1472
5190-1474
Plunger in needle, removable
23/70 mm/cone tip
Replacement needle and plunger kit
for 5.0 µL syringe
5190-1475
5190-1477
Plunger in needle, removable
23/70 mm/bevel tip
Replacement needle and plunger kit
for 5.0 µL syringe
5190-1476
5190-1478
Straight, fixed
26/50 mm/bevel tip
Removable, with flexible plunger
70
5190-1464
5190-1468
Plunger in needle, removable
Replacement needle for 5.0 µL syringe
5190-1466
5190-1470
Replacement needle and plunger kit
for 1.0 µL syringe
5.0
5190-1463
5190-1467
Plunger in needle, removable
2.0
5190-1460
5190-1462
Replacement needle and plunger kit
for 1.0 µL syringe
Manual syringe, 1.0 µL,
RN cone tip, 5190-1463
Part No.
5190-0464
26/50 mm/bevel tip
3/pk
5190-1479
5190-1481
5190-1482
AGiLENT SyriNGES
Manual Syringes with Fitted Plunger, Fixed and removable Needle, 10 to 500 µL
Volume
(µL)
Description
Needle
Part No.
10
Fixed
26/50 mm/bevel tip
5190-1483
Fixed
10/pk 26/50 mm/bevel tip
5190-1487
26/50 mm/bevel tip
5190-1488
26/50 mm/bevel tip
5190-1489
25/50 mm/bevel tip
5190-1493
25/50 mm/bevel tip
5190-1495
25/50 mm/bevel tip
5190-1500
25/50 mm/bevel tip
5190-1502
unit
Fixed, with flexible plunger
Fixed, with flexible plunger
25
6/pk
Fixed
Removable
Replacement needle
50
3/pk
Fixed
Removable
Replacement needle
100
5190-1496
25/50 mm/bevel tip
5190-1507
Removable
25/50 mm/bevel tip
5190-1509
Fixed
25/50 mm/bevel tip
5190-1514
Removable
25/50 mm/bevel tip
5190-1516
Replacement needle
500
3/pk
Fixed
Replacement needle
250
5190-1496
3/pk
3/pk
Fixed
Removable
Replacement needle
5190-1496
3/pk
5190-1496
25/50 mm/bevel tip
5190-1521
25/50 mm/bevel tip
5190-1524
Manual syringe, 50 µL, FN bevel tip, 5190-1500
5190-1496
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
71
AGiLENT SyriNGES
Manual Syringes with PTFE-Tipped Plunger, removable Needle, 10 to 500 µL
Volume
(µL)
Description
10
Removable
Replacement needle
unit Needle
25/50 mm/bevel tip
3/pk
5190-1559
Removable
Replacement needle
25/50 mm/bevel tip
3/pk
5190-1560
Removable
Replacement needle
25/50 mm/bevel tip
3/pk
5190-1561
Removable
Replacement needle
25/50 mm/bevel tip
3/pk
5190-1562
Removable
Replacement needle
25/50 mm/bevel tip
3/pk
Replacement needle
72
5190-1563
Removable
Replacement plunger with PTFE tip
for 500 µL syringe
5190-1518
5190-1496
Replacement plunger with PTFE tip
for 250 µL syringe
500
5190-1511
5190-1496
Replacement plunger with PTFE tip
for 100 µL syringe
250
5190-1504
5190-1496
Replacement plunger with PTFE tip
for 50 µL syringe
100
5190-1498
5190-1496
Replacement plunger with PTFE tip
for 25 µL syringe
50
5190-1491
5190-1496
Replacement plunger with PTFE tip
for 10 µL syringe
25
Part No.
25/50 mm/bevel tip
3/pk
5190-1525
5190-1496
5190-1564
AGiLENT SyriNGES
Manual Syringes with PTFE-Tipped Plunger, Fixed Needle, 10 to 500 µL
Volume (µL) Description
Needle
Part No.
10
26/50 mm/bevel tip
5190-1490
25/50 mm/bevel tip
5190-1497
Fixed
Replacement plunger with PTFE tip for 10 µL syringe
25
Fixed
50
Fixed
5190-1558
Replacement plunger with PTFE tip for 25 µL syringe
5190-1560
25/50 mm/bevel tip
5190-1503
25/50 mm/bevel tip
5190-1510
Replacement plunger with PTFE tip for 50 µL syringe
100
Fixed
250
Fixed
5190-1561
Replacement plunger with PTFE tip for 100 µL syringe
5190-1562
25/50 mm/bevel tip
5190-1517
25/50 mm/bevel tip
5190-1523
Replacement plunger with PTFE tip for 250 µL syringe
500
Fixed
5190-1563
Replacement plunger with PTFE tip for 500 µL syringe
5190-1564
Manual Syringes with PTFE-Tipped Plunger, removable Needle, 1 mL to 10 mL
Volume (mL) Description
1.0
unit Needle
Removable
23/50 mm/bevel tip
Replacement needle
3/pk
23/50 mm/bevel tip
3/pk
5190-1572
Removable
23/50 mm/bevel tip
Replacement needle
3/pk
5190-1573
Removable
23/50 mm/bevel tip
Replacement needle
3/pk
Replacement plunger with PTFE tip for 10 mL
syringes
5190-1537
5190-1538
Replacement plunger with PTFE tip for 5 mL
syringes
10
5190-1533
5190-1581
Replacement plunger with PTFE tip for 2.5 mL
syringes
5.0
Manual syringe, 500 µL, FN bevel tip, 5190-1523
5190-1565
Removable
Replacement needle
5190-1529
5190-1581
Replacement plunger with PTFE tip for 1 mL
syringes
2.5
Part No.
5190-1542
5190-1538
5190-1574
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
73
AGiLENT SyriNGES
Manual Syringes with PTFE-Tipped Plunger, Fixed Needle, 1 mL to 10 mL
Volume (mL)
Description
Needle
Part No.
1.0
Fixed
22/50 mm/bevel tip
5190-1528
22/50 mm/bevel tip
5190-1532
Replacement plunger with PTFE tip for 1 mL syringes
2.5
5190-1565
Fixed
Replacement plunger with PTFE tip for 2.5 mL
syringes
5.0
5190-1572
Fixed
22/50 mm/bevel tip
Replacement plunger with PTFE tip for 5 mL syringes
10
5190-1536
5190-1573
Fixed
22/50 mm/bevel tip
Replacement plunger with PTFE tip for 10 mL syringes
5190-1541
5190-1574
Manual Syringe with PTFE-Tipped Plunger and Luer Lok, 50 to 500 µL
Volume
(µL)
Description
Needle
Part No.
50
Luer Lok
Luer Lok/50 mm or 2 in
5190-1506
Replacement plunger with PTFE tip
for 50 µL syringe
100
Manual syringe, 1 mL, FN bevel tip, 5180-1528
Luer Lok
5190-1561
Luer Lok/50 mm or 2 in
Replacement plunger with PTFE tip
for 100 µL syringe
250
Luer Lok
Luer Lok/50 mm or 2 in
Replacement plunger with PTFE tip
for 250 µL syringe
500
Luer Lok
Replacement plunger with PTFE tip
for 500 µL syringe
74
5190-1513
5190-1562
5190-1519
5190-1563
Luer Lok/50 mm or 2 in
5190-1527
5190-1564
AGiLENT SyriNGES
Manual Syringe with PTFE-Tipped Plunger and Luer Lok, 1 to 50 mL
Volume
(mL)
Description
Needle
Part No.
1.0
Luer Lok
Luer Lok/50 mm or 2 in
5190-1530
Luer Lok valve
Luer Lok valve/50 mm or 2 in
5190-1531
Replacement plunger with PTFE tip
for 1 mL syringes
2.5
5190-1565
Luer Lok
Luer Lok/50 mm or 2 in
5190-1534
Luer Lok valve
Luer Lok valve/50 mm or 2 in
5190-1535
Replacement plunger with PTFE tip
for 2.5 mL syringes
5.0
5190-1572
Luer Lok, 5190-1534
Luer Lok
Luer Lok/50 mm or 2 in
5190-1539
Luer Lok valve
Luer Lok valve/50 mm or 2 in
5190-1540
Replacement plunger with PTFE tip
for 5 mL syringes
10
5190-1573
Luer Lok
Luer Lok/50 mm or 2 in
5190-1457
Luer Lok valve
Luer Lok valve/50 mm or 2 in
5190-1543
Replacement plunger with PTFE tip
for 10 mL syringes
25
5190-1574
Luer Lok
Luer Lok/50 mm or 2 in
Replacement plunger with PTFE tip
for 25 mL syringe
Luer Lok valve, 5190-1543
5190-1544
5190-1575
Luer Lok valve
Luer Lok valve/50 mm or 2 in
Replacement plunger with PTFE tip
for 25 mL syringe
50
Luer Lok valve, 5190-1531
5190-1545
5190-1576
Luer Lok
Luer Lok/50 mm or 2 in
5190-1546
Luer Lok valve
Luer Lok valve/50 mm or 2 in
5190-1547
Replacement plunger with PTFE tip
for 50 mL syringes
5190-1577
Luer Lok and Luer Lok Valve Needles
Description
unit
Needle
Part No.
Luer Lok needle
3/pk
23/50/bevel tip
5190-1548
Luer Lok needle
3/pk
23/50/sidehole tip
5190-1549
Luer Lok needle
3/pk
22/51/LC tip
5190-1550
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
75
AGiLENT SyriNGES
Lc Manual Syringes with Fitted Plungers
Volume (µL)
Description
unit Needle
Part No.
5
Fixed
22 gauge/2 in/LC tip
5190-1480
10
Fixed
22 gauge/2 in/LC tip
5190-1484
Removable
22 gauge/2 in/LC tip
5190-1485
Replacement needle for 10 µL syringe
3/pk
5190-1486
25
Fixed
22 gauge/2 in/LC tip
5190-1494
50
Fixed
22 gauge/2 in/LC tip
5190-1501
100
Fixed
22 gauge/2 in/LC tip
5190-1508
250
Fixed
22 gauge/2 in/LC tip
5190-1515
500
Fixed
22 gauge/2 in/LC tip
5190-1522
Lc Manual Syringes with PTFE-Tipped Plungers
Volume (µL)
Description
10
Removable
Replacement needle for 10 µL syringe
unit Needle
22 gauge/2 in/LC tip
3/pk
25
5190-1558
Removable
Replacement needle
22 gauge/2 in/LC tip
3/pk
5190-1560
Removable
Replacement needle
22 gauge/2 in/LC tip
3/pk
5190-1561
Removable
Replacement needle
22 gauge/2 in/LC tip
3/pk
500
22 gauge/2 in/LC tip
3/pk
Removable
Replacement needle
Replacement plunger with PTFE tip
for 500 µL syringe
76
5190-1562
Removable
Replacement needle
5190-1512
5190-1571
Replacement plunger with PTFE tip
for 100 µL syringe
250
5190-1505
5190-1571
Replacement plunger with PTFE tip
for 50 µL syringe
100
5190-1499
5190-1571
Replacement plunger with PTFE tip
for 25 µL syringe
50
5190-1492
5190-1486
Replacement plunger with PTFE tip
for 10 µL syringe
Syringe, 100 µL FN LC tip, 5190-1508
Part No.
5190-1571
22 gauge/2 in/LC tip
3/pk
5190-1520
5190-1526
5190-1571
5190-1564
AGiLENT crOSSLAB SyriNGES
Agilent CrossLab Syringes
crossLab Gc Autosampler Syringes
With a broad selection of syringes for auto injection, CrossLab autosampler syringes provide what you need
for accurate and effective sampling. CrossLab syringes meet all fit, form, and function criteria for specific
autosampler models. Agilent delivers more value in every autosampler syringe:
• Lot number printed directly on the barrel with a corresponding Certificate of Conformance
• Illuminating backing strip, for effortless viewing of the volume scale
• Environmentally friendly packaging and improved design that reduces waste
• Individually packaged for contaminant-free use right out of the box
Typical Needle Gauge Dimensions
OD
iD
Gauge
mm
inches
mm
inches
23
0.64
0.0248
0.11
0.0043
25
0.50
0.0197
0.20
0.0079
26
0.47
0.0184
0.11
0.0043
Autosampler syringe, 10 µL fixed needle, 8010-0351
Autosampler syringe, 5 µL, fixed needle, 8003-0001
Autosampler syringe, 5 µL, gas tight, fixed needle, 8003-0002
TiPS & TOOLS
Replace syringe if dirt is noticeable,
syringe cannot be cleaned or
plunger doesn't slide easily.
Replace needle if septa wear is
abnormal or needle is clogged.
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
77
AGiLENT crOSSLAB SyriNGES
Needle Gauge
Single Gauge 23 (0.64 mm)
Packed column injector ports
Split/splitless injector ports
Single Gauge 26 (0.47 mm)
Packed column injector ports
Split/splitless injector ports
Needle Termination
Needle terminations are available in fixed or removable, with various tip styles.
Fixed (cemented)
• Economical, reproducible injections for autosamplers
• Preferred for applications requiring trace level samples
• Recommended for use where probability of needle bending is minimal
• Can be heated up to 70 °C
Removable needle
• Versatile option for injections
• Needle can be replaced if damaged or clogged
• Allows needle to be changed for different applications
• Can be heated up to 120 °C
TiPS & TOOLS
Follow manufacturer's recommendation
for syringe cleaning and regularly inspect
syringe barrel for sample build-up and
needle tip for wear.
78
AGiLENT crOSSLAB SyriNGES
Autosampler Syringes for Bruker/Varian Gc Systems, 1/pk
Model
Volume
(µL) Description
Needle Gauge/
Length (mm)/
Tip
Agilent
crossLab
Syringe
Part No.
Similar to
Bruker/Varian
Syringe Part No.
SG002981
CP8400
CP8410
CP9010
CP9050
AS200
AS2000
AS3000
AS800
TriPlus
10
Fixed needle
23/50/cone tip
8010-0351
CP8400
CP8410
CP9010
CP9050
10
Fixed needle
26/50/bevel tip
8004-0001
CP8400
CP8410
CP9010
CP9050
10
Removable needle
26/50/cone tip
8004-0003
8035
8100
8200
10
Fixed needle, gas tight
26/53/side hole tip
8004-0002
10
Removable needle,
gas tight
25/53/side hole tip
8004-0005
CP8400
CP8410
CP9010
CP9050
10
Replacement needle
8004-0004
8035
8100
8200
10
Replacement needle
8004-0006
8035
8100
8200
10
Replacement plunger
8004-0007
SG002982
Agilent crossLab
replacement
Needle Part No.
Agilent crossLab
replacement
Plunger Part No.
8004-0004, 2/pk
8004-0007
8004-0006, 2/pk
8004-0007
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable alternatives
to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts.
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
79
AGiLENT crOSSLAB SyriNGES
Autosampler Syringes for PerkinElmer Gc Systems, 1/pk
Model
Autosystem
Autosystem XL
Clarus
5
50
Similar to
PerkinElmer
replacement
Needle and Plunger
repair Kit Part No.
N6101252
8003-0006
N6101469
Needle Gauge/
Length (mm)/
Tip
Removable
needle
23/70/cone tip
8003-0005
Removable
needle
26/70/bevelled
cone tip
8003-0007
Fixed needle
23/70/cone tip
8003-0001
N6101251
Fixed needle,
gas tight
23/70/cone tip
8003-0002
N6101390
Fixed needle
26/70/cone tip
8003-0003
N6101380
Fixed needle
23/70/cone tip
8003-0004
N6101760
Replacement
needle and
plunger
repair kit
8003-0006
N6101469
Replacement
needle and
plunger
repair kit
8003-0008
Volume
(µL) Description
0.5
Similar to
PerkinElmer
Syringe Part No.
Agilent crossLab
replacement
Needle and Plunger
repair Kit Part No.
Agilent
crossLab
Syringe
Part No.
8003-0008
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable alternatives
to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts.
80
AGiLENT crOSSLAB SyriNGES
Autosampler Syringes for Shimadzu Gc Systems, 1/pk
Model
AOC-14
AOC-17
AOC-20
Volume
(µL) Description
Needle Gauge/
Length (mm)/
Tip
Agilent
crossLab
Syringe
Part No.
Similar to
Agilent crossLab
Shimadzu Syringe replacement
Part No.
Needle Part No.
Similar to Shimadzu
replacement
Needle Part No.
5
Fixed needle
23/42/cone tip
8001-0001
10
Removable needle
23/42/cone tip
8001-0004 220-90282-20
8001-0005, 2/pk
220-90281-20
8001-0007, 2/pk
220-90281-21
Removable needle
26/42/cone tip
8001-0006 220-90282-21
50
Fixed needle
23/42/cone tip
8001-0002 221-45243-00
250
Fixed needle,
gas tight
23/42/cone tip
8001-0003 221-45244-00
Autosampler Syringes for Shimadzu hPLc Systems, 1/pk
Model
SIL-10A
SIL-10Ai
Needle Gauge/
Length (mm)/
Tip
Volume
(µL) Description
Agilent
crossLab
Syringe
Part No.
Similar to
Agilent crossLab
Shimadzu Syringe replacement
Part No.
Needle Part No.
500
Chem (1/4-28 UNF
screw threads),
gas tight
8001-0401 228-25237-04
2.5
Chem (1/4-28 UNF
screw threads),
gas tight
8001-0402 228-25237-06
2.5
1/4-28 screw threads,
gas tight with bracket
8001-0404 228-28128-91
Similar to Shimadzu
replacement
Needle Part No.
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable alternatives
to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts.
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
81
AGiLENT crOSSLAB SyriNGES
Autosampler Syringes for Thermo Gc Systems, 1/pk
Model
Needle Gauge/
Length (mm)/
Tip
Agilent
crossLab
Syringe
Part No.
Agilent crossLab
Similar to Thermo replacement
Scientific Syringe Needle or Plunger
Part No.
Part No.
Plunger-in-needle
23/50/cone tip
8010-0355
36504045
Volume
(µL) Description
AS3000
TriPlus
0.5
TriPlus
5
Fixed needle
26/50/cone tip
8010-0353
36504047
CP8400
CP8410
CP9010
CP9050
AS200
AS2000
AS3000
AS800
TriPlus
10
Fixed needle
23/50/cone tip
8010-0351
36520060
AOC-14
AOC-17
AOC-20
10
Fixed needle
26/50/cone tip
8010-0352
365D3711
AS200
AS2000
AS3000
AS800
TriPlus
10
Fixed needle
25/50/cone tip
8002-0003
36500525
AS2000
TriPlus
10
Fixed needle
23/80/cone tip
8002-0002
36520061
AS2000
TriPlus
10
Fixed needle
26/80/cone tip
8002-0001
36502019
AS200
AS2000
AS800
TriPlus
100
Fixed needle,
gas tight
23/50/cone tip
8010-0354
AS2000
TriPlus
100
Removable needle,
gas tight
23/50/side hole
tip
8002-0004
Similar to
Thermo Scientific
replacement
Needle or Plunger
Part No.
8010-0367*
8010-0368**
36520050
8002-0005***
36540040
*Needle and plunger repair kit
**Replacement plunger
***Replacement needle
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable alternatives
to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts.
Needle and plunger repair kit, 8010-0367
82
Replacement plunger, 8010-0368
AGiLENT crOSSLAB SyriNGES
CrossLab Supplies for
CTC Analytics GC Autosamplers
Agilent's CrossLab portfolio includes a variety of syringes compatible with CTC Analytics GC PAL
and CombiPAL systems.
• Syringe capacities from 0.5 µL to 2.5 mL
• Fixed and removable needles
• Several needle tip styles to suit your application requirements
• High temperature syringes for headspace application with temperatures up to 150 °C
• PTFE plunger seal option for smooth, leak-free operation
• Syringe specifications are matched to CTC holders to ensure proper fit and reliable functioning
Autosampler Syringes for cTc combiPAL and Gc PAL, 1/pk
Volume (µL)
Description
Needle Gauge/Length (mm)/Tip
Agilent crossLab
Syringe Part No.
0.5
Plunger-in-needle
23/50/cone tip
8010-0355
5
Fixed needle
23/50/cone tip
8010-0356
Fixed needle
26/50/cone tip
8010-0353
Fixed needle
23/50/cone tip
8010-0351
Fixed needle
25/50/cone tip
8002-0003
Fixed needle
26/50/cone tip
8010-0352
Fixed needle, gas tight
26/50/cone tip
8010-0357
Fixed needle
26/50/bevel tip
8010-0358
25
Fixed needle
26/50/cone tip
8010-0360
100
Fixed needle, gas tight
23/50/cone tip
8010-0354
Removable needle, gas tight
23/50/side hole tip
8002-0004
Fixed needle
26/50/cone tip
8010-0361
Fixed needle, gas tight
26/50/cone tip
8010-0362
Needle Gauge/Length (mm)/Tip
Agilent crossLab
Syringe Part No.
10
250
Agilent crossLab
replacement Needle
or Plunger Part No.
8010-0367*
8010-0359**
8002-0005***
Agilent crossLab
replacement Plunger
Part No.
Volume (mL)
Description
1
Fixed needle, gas tight, headspace
23/56/side hole tip
8010-0363
8010-0365
2.5
Fixed needle, gas tight, headspace
23/56/side hole tip
8010-0364
8010-0366
*Needle and plunger repair kit
**Replacement plunger
***Replacement needle
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable alternatives
to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts.
Autosampler syringe, 10 µL fixed needle, 8010-0351
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
83
AGiLENT crOSSLAB SyriNGES
Autosampler Syringes for Dionex Lc Systems, 1/pk
Model
Volume (µL)
WPS-3000SL
ASI-100
Description
Needle Gauge/
Length (mm)/
Tip
Similar to
Dionex
Syringe
Part No.
Agilent
crossLab
Syringe
Agilent crossLab
replacement
Needle
25
Chem (1/4-28 UNF screw
threads), gas tight
6822.0001
8002-0405
250
Chem (1/4-28 UNF screw
threads), gas tight
6822.0003
8002-0407
100
Removable needle,
gas tight
5805.2920
8002-0401* 8002-0413, 6/pk
22s/51/3
Removable needle,
gas tight
22s/51/3
1,000
2,500
Removable needle,
gas tight
22/51/3
22/51/3
22/51/3
22s/51/3
Agilent
crossLab
replacement
Plunger
8002-0402
8002-0412, 6/pk
5805.2940
8002-0403* 8002-0414, 6/pk
8002-0406
8002-0415, 6/pk
5805.2950
8002-0404* 8002-0414, 6/pk
8002-0408
8002-0415, 6/pk
*Needles are sold separately
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable alternatives
to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts.
Chem (1/4-28 UNF screw threads), gas tight, 8002-0405
84
Removable needle, gas tight, 8002-0401
AGiLENT crOSSLAB SyriNGES
Autosampler Syringes for waters Lc Systems, 1/pk
Model
2777 Compact Sample Manager
2777 Sample Manager
Agilent
crossLab
Syringe
Part No.
Similar to
waters
Syringe
Part No.
Agilent
crossLab
replacement
Needle or
Plunger
Part No.
Volume
(µL)
Description
Needle Gauge/
Length (mm)/
Tip
1
Fixed needle, gas tight
22/51/3
8010-0443
430000867
8010-0455
8010-0448
2.5
Fixed needle, gas tight
22/51/3
8010-0444
430000868
10
Fixed needle
22s/51/3
8010-0445
430000859
25
Fixed needle, gas tight
22s/51/3
8010-0441
430000861
100
Fixed needle, gas tight
22s/51/3
8010-0442*
430000864
Fixed needle, gas tight
22/51/3
8010-0446*
430000863
250
Fixed needle, gas tight
22/51/3
8010-0467
430000865
500
Fixed needle, gas tight
22/51/3
8010-0468
430000866
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
CapLC System
CapLC XE System
10000
Luer Lock
No needle
8005-0414
WAT025559
600 MultiSolvent Delivery System
Rheodyne Injector
25
Removable needle,
gas tight
22s/51/3
8005-0416
WAT033381
Rheodyne Injector
100
Removable needle,
gas tight
22s/51/3
8005-0417
WAT033383
2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
LC Module 1
717/717plus Autosampler
25
Chem (1/4-28 UNF
screw threads), gas tight
No needle
8005-0420
WAT077343
250
Chem (1/4-28 screw
threads UNF), gas tight
No needle
8005-0419
WAT073109
8010-0460,
10/pk**
8005-0418, 6/pk
*Barrel od is 6.7 mm. All other 10, 25, and, 100 µL syringes have 7.9 mm od.
**Replacement plunger
The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable alternatives
to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts.
Autosampler syringe, Luer Lock, 8005-0414
Autosampler syringe, gas tight, 8005-0417
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
85
cTc AuTOSAMPLEr SuPPLiES
CTC Autosampler Supplies
To better serve Agilent instrument users who choose CTC Analytics autosamplers for high-throughput and
flexible sample introduction, Agilent has partnered with CTC to provide a fully integrated system, including
CTC approved consumables.
Agilent's portfolio includes a variety of vials, caps, syringes, and well plates compatible with the CTC
Analytics HTC PAL, GC PAL, and CombiPAL systems.
combiPAL and Gc PAL Liquid injection Syringes
A key feature of CTC's GC PAL and CombiPAL is the ability to inject a wide range of sample volumes, up to
500 µL for LVI applications. The following fixed needle syringes are recommended by CTC to sustain high
reproducibility and accuracy.
combiPAL and Gc PAL Liquid injection Syringes
Volume
(µL)
Description
1.2
Fixed needle
5
CTC syringes
25
Fixed needle, G6500-80120
26/51/AS
G6500-80114
26/51/AS
5190-3984
26s/51/AS
G6500-80116
Fixed needle, Merlin & PTV
23s/51/AS
5188-6596
Fixed needle
For vials and caps that work
seamlessly with your CTC
Analytics PAL Autosamplers,
see our complete Vials and
Closures section, turn to page 27.
86
26/51/AS
10/pk
Fixed needle
Fixed needle
G6500-80115
G6500-80117
G4200-80104
26/51/AS
10/pk
Fixed needle
Replacement plunger
TiPS & TOOLS
5190-3985
26/51/2
Replacement plunger
500
3/pk
Fixed needle
Replacement plunger
250
Part No.
G6500-80113
Fixed needle
Replacement plunger
100
Needle
26/51/AS
Removable needle for Cool On-Column (COC)
Replacement removable needle
for Cool On-Column (COC)
10
unit
G6500-80118
G4200-80105
26/51/AS
G6500-80119
26/51/AS
G6500-80120
10/pk
G4200-80102
G4200-80106
cTc AuTOSAMPLEr SuPPLiES
combiPAL headspace Supplies
Our fixed needle headspace syringes feature a sideport needle for gas flushing, in conformance with strict
CTC standards. Use with Agilent’s Merlin Microseal to minimize instrument downtime and to prevent lost
or compromised data caused by septum leaks and liner contamination.
combiPAL headspace Syringes
Volume (mL)
Description
Gauge
1
Fixed needle
23
Fixed needle
G4200-80101
23
G6500-80109
Replacement plunger
5
Fixed needle
Headspace Vials
G6500-80107
Replacement plunger
2.5
Part No.
G4200-80107
23
G6500-80111
Replacement plunger
G4200-80108
combiPAL headspace Supplies
Description
Part No.
Liner, inlet for SPME, deactivated
5188-6471
Liner, Ultra Inert for SPME, straight
5190-4048
Fixed needle, G6500-80109
hTS and hTc PAL Liquid injection crimp Top
Micro Vials and caps
HTS and HTC PAL high-throughput LC injection systems are configured to cope with today's
high-throughput LC/MS demands. Agilent offers a selection of crimp top micro vials designed
specifically for HTS and HTC PAL systems.
hTS and hTc PAL Liquid injection crimp Top Micro Vials and caps
Description
unit
Part No.
0.8 mL, amber glass, flat bottom
1000/pk
5183-4487
0.1 mL, clear glass, tapered bottom
500/pk
5180-0844
0.3 mL, clear glass, round bottom
500/pk
5180-0841
0.7 mL, amber glass, round bottom
500/pk
5180-0805
0.5 mL, amber glass, conical bottom
500/pk
5180-0806
500/pk
5180-0842
Micro caps
Crimp caps with PTFE/silicone septa
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
87
cTc AuTOSAMPLEr SuPPLiES
hTS and hTc PAL Liquid injection Syringes
Designed specifically for CTC autosamplers, these X-type syringes feature zero carryover and a long-lasting
plunger for applications that demand precision and productivity. They are strongly recommended for
high-throughput applications.
Agilent offers a wide selection of fixed needle, 22-gauge, pointstyle 3 syringes to accommodate a variety
of applications.
hTS and hTc PAL Liquid injection Syringes
Volume (µL) Description
25
Replacement plunger for X-type syringe
X-type fixed needle, G4200-80118
50
25
G4200-80118
G4200-80119
3/pk
Fixed needle
G4200-80111
22s/51/3
10/pk
Fixed needle
22s/51/3
10/pk
Fixed needle
22/51/3
G4200-80115
22s/51/3
G4200-80116
22/51/3
G6500-80102
10/pk
Fixed needle
Fixed needle
G4200-80105
10/pk
G4200-80102
22/51/3
Fixed needle
Fixed needle
22/51/3
Fixed needle
Replacement plunger
88
G6500-80104
G4200-80101
22/51/3
Replacement plunger
5000
G6500-80103
G4200-80106
Replacement plunger
2500
G4200-80114
G4200-80104
Replacement plunger
1000
G4200-80113
G4200-80103
Fixed needle
Replacement plunger
500
5188-6485
5188-5395
22/51/3
Replacement plunger
250
22/51/3
3/pk
22s/51/3
Replacement plunger
100
G4200-80112
X-type fixed needle, fast aspiration and eject
Replacement plunger
Replacement plunger, G4200-80111
Part No.
G4200-80117
X-type fixed needle, low dead volume
Replacement plunger for X-type syringe
10
Needle
22s/51/3
3/pk
X-type fixed needle
Replacement plunger for X-type syringe
100
unit
X-type fixed needle
G6500-80105
G4200-80107
22/51/3
G6500-80106
G4200-80108
cTc AuTOSAMPLEr SuPPLiES
hTS and hTc PAL Liquid injection Valve Supplies
Whether your HTS or HTC PAL autosampler uses the Agilent proprietary Rheodyne high-pressure 600 bar
injection valve or Valco Cheminert injection valves, Agilent can help you find a sample loop to meet your
most challenging applications – including:
• Rheodyne 600 bar injection valve loops, which include high-pressure Swagelok fittings
• Cheminert metal loops, which feature two 1/16 in stainless steel nuts and two stainless steel ferrules
• Cheminert PEEK loops, which include two PEEK nuts and two PEEK ferrules
hTS and hTc PAL Liquid injection Valve Loops and Needle Seals
Description
Part No.
rheodyne 600 bar Valve Supplies
Stainless Steel Loops: Supplied with Swagelok fittings required for high pressure
5 µL
5188-6486
10 µL
5188-6487
20 µL
5188-6488
50 µL
5188-6489
100 µL
5188-6490
Stator, Rheodyne 600 bar
Stainless steel loop, 5188-6486
5188-6491
RheBuild Kit, 600 bar, includes Rotor Seal and 3/32 in hex wrench
5188-6492
Needle Seals, Rheodyne valve, 600 bar, 10/pk
5188-6478
cheminert Valve Supplies
PEEK Loops: Include two PEEK nuts and two PEEK ferrules
2 µL
5188-6469
5 µL
5188-6470
10 µL
5188-6467
20 µL
5188-6468
2 µL PEEK loop, 5188-6469
Metal Loops: Include two 1/16 in stainless steel nuts and two stainless steel ferrules
2 µL
5188-6457
10 µL
5188-6458
50 µL
5188-6460
100 µL
5188-6461
250 µL
5188-6462
500 µL
5188-6463
1000 µL
5188-6464
2000 µL
5188-6465
5000 µL
5188-6466
PEEK Needle Seal, Valco, 22-gauge, 10/pk
5188-6476
PTFE Needle Seal, Valco, 22-gauge, 10/pk
5188-6477
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
10 µL PEEK loop, 5188-6467
89
cTc AuTOSAMPLEr SuPPLiES
cTc Autosampler General Supplies
For your convenience, Agilent offers a selection of replacement sampling trays, well plates and sampling
accessories for CTC autosamplers.
Description
Sample tray, G6500-80101
Collection plate, showing
96-position closing mat, 5042-1389
Well plate foil cutter, 5188-6479
90
Part No.
Sample tray, 200 vials, 0.7 or 1 mL
G6500-80100
Sample tray, 98 2 mL or 78 1 mL vials
G6500-80101
Sample tray, 32 10 or 20 mL vials
G6500-80121
Sample tray, 54 2 mL vials, for PAL deep-well stack
G6500-80122
96-well plates, 0.5 mL, polypropylene, 10/pk
5042-1386
96-deep well plates, 1 mL, polypropylene, 50/pk
5042-6454
384-well plates, 90 µL, polypropylene, 30/pk
5042-1388
Closing mats for 96-well plates, silicone, pre-slit, fits 96-well plates P/N 5042-1385
and 5042-1386 only, 50/pk
5042-1389
Well plate foil cutter, max 22-gauge needle
5188-6479
GAS MANAGEMENT
Gas Management
Gas Purification
Impure gases can cause installation delays, premature instrument failure, and flawed results. Purification
is one of the most important steps you can take to optimize your system performance.
Agilent brings the highest performance of gas purifiers to gas chromatographers. We manufacture purifiers
in a variety of sizes and configurations to remove oxygen, moisture, and hydrocarbons. We recommend
that each gas chromatograph use a gas purification system with removable cartridges such as Gas Clean
or Renewable. These systems ensure the highest quality gas and contain indicators to allow for timely
replacement before other consumables, like columns and liners, are damaged and sensitivity decreases.
Agilent Gas Purifiers are a cost effective safety and preventive measure to assure the supply of the highest
purity gas to your GC and GC/MS instrumentation with considerable savings in laboratory gas costs. We also
carry a line of in-line purifiers to provide high capacity or economy solutions for customers. Please refer to
the Gas Purifier Selection Guide to determine which gas purifiers you should use, see page 95.
carrier Gas Purification
The Carrier Gas Purification illustration on the next page shows the most common gas purification
configurations used in gas chromatography.
Regardless of which purification system is employed, proper installation and maintenance are required to
achieve optimal performance. A purifier that is not maintained will eventually expire and become ineffective,
or worse, a source of contamination.
Gas Clean Filters
Helpful Hints for Purification Success
• Keep number of fittings in gas line to a minimum
• Install purifiers in a convenient location close to the GC
• Use purifier log books to determine maintenance and cartridge replacement schedules
• Use indicating traps closest to the GC so you can determine when to change the traps
that are upstream
TiPS & TOOLS
View the latest Agilent J&W GC
column focused applications,
products and educational resources at
www.agilent.com/chem/mygccolumns
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
91
GAS MANAGEMENT
connection Diagrams for common Detectors
Detector
EcD
connection Diagrams
Carrier Gas
Oxygen Filter
Moisture Filter
Nitrogen
Oxygen Filter
Moisture Filter
Column
Electron Capture Detector
Anode Purge
Gas
Make-Up Gas
ECD
FiD
Carrier Gas
Oxygen Filter
Hydrogen
Charcoal Filter
Air
Charcoal Filter
Carrier Gas
GC/MS Filter
Make-Up Gas
Charcoal Filter
Hydrogen
Charcoal Filter
Air
Charcoal Filter
Moisture Filter
Column
Flame Ionization Detector
(Carrier Gas = Make-Up Gas)
FID
FiD
Column
Flame Ionization Detector
(Carrier Gas differs from Make-Up Gas)
FID
92
GAS MANAGEMENT
Detector
FPD
connection Diagrams
Carrier Gas
Oxygen Filter
Hydrogen
Charcoal Filter
Moisture Filter
Column
Flame Photometric Detector
Flame 1
PFPD
Pulsed Flame Photometric Detector
Air
Charcoal Filter
FPD
Flame 2
MS (iTD, MSD)
Carrier Gas
GC/MS Filter
Column
Ion Trap Detector,
Mass Selective Detector
Two Possibilities
(see diagrams to the right)
MS
Carrier Gas
Oxygen Filter
Moisture Filter
Column
MS
NPD, PND
Carrier Gas
Oxygen Filter
Moisture Filter
Column
Nitrogen-Phosphorus Detector
Make-Up Gas
TiD, TSD
Thermionic Detector
(Carrier Gas = Make-Up Gas)
TcD
Hydrogen
Charcoal Filter
Air
Charcoal Filter
Carrier Gas
Oxygen Filter
TSD
Moisture Filter
Column
Thermal Conductivity Detector
Reference Channel
Make-Up Gas,
if necessary
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
TCD
93
GAS MANAGEMENT
connection Diagrams Analyzers and Generators
Detector
connection Diagrams
icP-OES/icP-MS
Oxygen Filter
Inductively Coupled Plasma-Optical
Emission Spectrometry/Mass
Spectrometry
Supply Gas
ICP-MS
ICP-OES
Oxygen Filter
(Plasma Gas = Nebulizer Gas)
icP-OES
Oxygen Filter
Inductively Coupled Plasma-Optical
Emission
Supply Gas
ICP-OES
Oxygen Filter
(Different Optic Flush Gas)
High-Flow Base Plate
Optic Flush Gas
Total Organic carbon (TOc)
Analyzer
Zero-Air Generator
Oxygen Filter
Carrier Gas
CO2 Filter
Moisture Filter
TOC Analyzer
Carrier Gas
CO2 Filter
Moisture Filter
Zero-Air Generator
Key:
Gc/MS Filter: A triple filter that removes oxygen, moisture, and hydrocarbons
Oxygen Filter: A filter that removes oxygen
Moisture Filter: A filter that removes water
charcoal Filter: A filter that removes hydrocarbons
cO2 Filter: A filter that removes carbon dioxide
94
GAS MANAGEMENT
Gas Purifier Selection Guide
contaminant
Description
Series
unique Features
Page No.
Ships standard with GC/MS Systems,
highly sensitive indicators with fast,
leak-free filter replacement
96
Recyclable high-capacity system filters moisture,
oxygen and hydrocarbons in a small, singlecartridge unit, featuring quick changes and
easy-to-read dual indicators
100
Glass construction with plastic safety shield
104
Ultra-high capacity for moisture
103
Glass construction with plastic safety shield
105
Purification Systems
Hydrocarbon
Moisture
Oxygen
Triple Filter (GC/MS)
Carbon Dioxide
Renewable Types:
Triple Filter
Gas Clean Filters*
Renewable Gas Purification System
G3440
in-Line Purifiers
Moisture (H2O)
Indicating Moisture Traps
Big Moisture Traps
Oxygen (O2)
Hydrocarbons (HCs)
Combination Traps
BMT
Indicating Oxygen Traps
Oxygen Traps
OT1
Economical non-indicating oxygen trap
106
Big Oxygen Traps
BOT
Ultra-high capacity for oxygen
103
Hydrocarbon Traps
HT
Economical trap for hydrocarbons
106
Big Hydrocarbon Traps
BHT
Ultra-high capacity for hydrocarbons
103
Oxygen/Moisture Trap
OT3
Economical bi-functional trap
108
Hydrocarbon/Moisture Trap
HMT
Economical bi-functional trap
109
Big Universal Trap
RMS
Gas-specific (for purifying He, N2, or H2),
ultra-high capacity, removes H2O, O2, HCs,
CO, and CO2, recommended for GC and
GC/MS gas supplies
101
Split Vent Trap
RDT
Cartridge design with durable cartridge holder
and replacement cartridges
109
Other Purifiers
Organics
*Agilent Recommended
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
95
GAS MANAGEMENT
Gas Purification Systems
Agilent Gas clean Filters
• Deliver clean gases for accurate analyses
• Fast, leak-free filter replacement reduces downtime
• Economical, with immediate payback
• Highly sensitive filter indicators provide maximum instrument protection
The Agilent Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity
loss, and instrument downtime. Inserting a Gas Clean Filter System in the gas line immediately before the
instrument inlet greatly reduces the level of impurities, thus improving trace analysis. Contaminants entering
your GC column will also be reduced, which is critical for high temperature analysis and essential for longer
column lifetime.
Replacing the filters when they have reached absorption capacity ensures maximum protection of your
GC columns and analytical hardware. The sensitive indicators change color, alerting you that the filter
needs to be replaced.
A Gas Clean Filter System allows you to use 99.996% (4.6) pure helium instead of the more expensive
99.999% (5.0) or 99.9999% (6.0) grade, while still yielding high quality analytical results. The expected
cost savings are 30%.
The unique connection design allows fast, leak-free
replacement of the Gas Clean Filter
TiPS & TOOLS
Learn best practices for GC troubleshooting with the Agilent GC Troubleshooting
video series – view at www.agilent.com/chem/Gctroubleshooting
96
GAS MANAGEMENT
Benefits of using Gas clean Filters
Technique
Filters
Benefit
GC/MS
GC/MS filter
Higher data accuracy and less maintenance
GC column
Moisture filter and oxygen filter or a GC/MS filter
Longer lifetime
ECD detector
GC/MS Filter
Greater sensitivity
TCD detector
Moisture filter and oxygen filter or a GC/MS filter
Greater sensitivity and less maintenance
Process GC
Process moisture filter
Long term stability
FID detector
Two charcoal filters (for air and hydrogen)
Greater sensitivity
PID detector
Oxygen filter and charcoal filter
Greater sensitivity
PFPD or FDP detector
Charcoal filter, CO2 filter and moisture filter
Greater sensitivity
TSD or NPD detector
Charcoal filter, CO2 filter and moisture filter
Greater sensitivity
Total organic carbon
CO2 filter and moisture filter
Greater sensitivity
Zero-air generator
CO2 filter and moisture filter
Cleaner gas
ICP-OES, ICP-MS
High flow connection unit with two oxygen filters
Greater sensitivity
Gas clean Filters Technical Specifications
Description
Function
indicator color change
capacity
Outlet concentration
(at operating flow
of 1-10 L/min)
Oxygen Filter
Removes oxygen as well as
traces of sulfur and chlorine
compounds from carrier gas
From green to gray
150 mL oxygen
< 50 µg/L
Moisture Filter/Process
Moisture Filter
Removes water, oil,
and other foreign material
from the carrier gas
From green to pale brown
7.2 g water
< 0.1 mg/L
charcoal Filter
Removes organic compounds No indicator
from gas streams
Approximately 7 g,
depending on impurities
< 0.1 mg/L
Gc/MS Filter
Single combination filter,
removes water, oxygen,
and organic compounds
Oxygen, from green to gray;
Moisture, from green
to pale brown
100 mL oxygen, 1 g water,
organics depending
on impurities
Oxygen < 50 µg/L
Moisture < 0.1 mg/L
Organics < 0.1 mg/L
cO2 Filter
Removes CO2 from the
gas stream; use with
moisture filter
From white to violet
9 g CO2
< 1 mg/L
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
97
GAS MANAGEMENT
Agilent Gas clean Filter Starter Kits
Gas Clean Filters
1-position connecting unit, 1/8 in, CP7988
Description
Part No.
Agilent Gas Clean FID Filter kit
Includes a 4-position 1/8 in connecting unit and two Charcoal filters,
one Oxygen filter, and one Moisture filter
CP7995*
Agilent Gas Clean Filter Kit, 1/8 in
Includes a 4-position 1/8 in connecting unit and two Charcoal filters,
one Oxygen filter, and one Moisture filter
CP736530
Agilent Gas Clean GC/MS Filter kit
Includes a 1-position connecting unit 1/8 in and two GC/MS filters
CP17976
Agilent Gas Clean GC/MS Filter kit
Includes a 1-position connecting unit 1/4 in and two GC/MS filters
CP17977
Agilent Gas Clean GC/MS Filter Installation kit
Includes 1 m copper tubing (P/N CP17976), two nuts and two ferrules, 1/8 in
CP17978
Agilent Gas Clean CO2 kit
Includes 2-position 1/4 in connecting unit and CO2 and moisture filters
CP17982
Agilent Gas Clean CO2 kit
Includes 2-position 1/8 in connecting unit and CO2 and moisture filters
CP17983
Agilent TCD Filter Kit
Includes a 2-position 1/8 in connecting unit, one Oxygen filter, and one Moisture filter
CP738408
Agilent GC Installation Kit
Includes CP736530 and many useful fittings and accessories.
19199N
*For 1/8 in tube, use reducer 1/8 in x 1/4 in, P/N CP4392
connecting units
Description
4-position connecting unit, 1/8 in, CP736520
High flow connecting unit 1/8 in, CP17985
98
Part No.
1-position connecting unit, 1/4 in
CP7980
1-position connecting unit, 1/8 in
CP7988
2-position connecting unit, 1/4 in
CP738406
2-position connecting unit, 1/8 in
CP738407
4-position connecting unit, 1/4 in
CP7989
4-position connecting unit, 1/8 in
CP736520
High flow connecting unit, 2-position, 1/4 in
CP17984
High flow connecting unit, 2-position, 1/8 in
CP17985
1-position, stainless steel, 1/4 in tube
CP7980P4
1-position, stainless steel, 1/8 in tube
CP7988P8
1-position, stainless steel, 3 mm tube
CP7988P3
1-position, stainless steel, 6 mm tube
CP7980P6
GAS MANAGEMENT
replacement Gas clean Filters
Description
Part No.
Agilent Gas Clean CO2 filter
CP17969
Agilent Gas Clean Oxygen filter
CP17970
Agilent Gas Clean Moisture filter
CP17971
Agilent Gas Clean Process Moisture filter
CP17971P
Agilent Gas Clean Charcoal filter
CP17972
Agilent Gas Clean GC/MS filter*
CP17973
*GC/MS filter removes Hydrocarbons, Moisture, and Oxygen, and can be used to purify any GC carrier gas. It is the best
filter for protecting your inert consumables.
Agilent Gas Clean GC/MS filter, CP17973
Accessories and Fittings
Description
Part No.
Wall mounting bracket for connecting unit
For CP7980 and CP7988
CP7981
Upper part filter connecting unit
CP7978
Flush head for connecting unit
CP7987
Male connector, 1/4 in with dust filter
CP7986
Male connector, 1/8 in with dust filter
CP82117
Viton O-rings, two sets
CP7983
Male connector, stainless steel, 1/4 in with dust filter
CP7986SS
Male connector, stainless steel, 1/8 in with dust filter
CP82117SS
Male connector, stainless steel, 3 mm with dust filter
CP82117SS3
Male connector, stainless steel, 6 mm with dust filter
CP7986SS6
Wall mounting bracket for connecting unit, for
CP7980 and CP7988, CP7981
Flush head for connecting unit, CP7987
TiPS & TOOLS
GC/MS filter removes Hydrocarbons,
Moisture, and Oxygen and can be
used to purify any GC carrier gas.
It is the best filter for protecting your
inert consumables.
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
99
GAS MANAGEMENT
renewable Gas Purification System
The Renewable Gas Purification System from Agilent not only traps large quantities of contaminants and
lasts a long time, but it is also recyclable. With average use, you'll only need to purchase a replacement
cartridge once per year or after approximately 20 cylinders' worth of purification. When you need a
replacement, you have the option to purchase a new or recycled cartridge. Recycled cartridges are refilled
and certified to the full specifications of the new cartridges.
• Agilent's highest capacity and most economical purification system
• All cartridges are environmentally friendly and reduce waste
• High capacity – 850 cc or more oxygen filtration, 12 g H2O, and approximately 8 g hydrocarbon
filtration per cartridge – in a compact footprint
Renewable gas purification system (left)
and recycled cartridge (right)
• Improves 99.995% gas purity to 99.9995% purity
• Dual indicators make it easy to see the purification results
• Labeling displays indicator color and shape for accurate reading
• Simple twist on/off knob and guide rod make cartridge changes quick and easy
• One renewable gas purifier system can support up to four GC systems
• Designed with efficiency, safety, and environmental responsibility in mind
• All replacement cartridges include return packaging and instructions
renewable Gas Purification System
Renewable gas purifier cartridge, new,
G3440-60003
TiPS & TOOLS
For more information about the
Renewable Gas Purification System, visit
www.agilent.com/chem/renewable
100
Description
Part No.
Renewable gas purifier system startup kit
Includes one G3440-80007 base, one G3440-60003 renewable gas purifier cartridge,
wall or bench mount hardware, and instruction manual
G3440-60004
Renewable gas purifier cartridge, new
G3440-60003
Renewable gas purifier cartridge, recycled
G3440-69003
Renewable gas purifier system, base only
G3440-80007
Return packaging set
For return of G3440-60003 or G3440-69003 renewable gas purification cartridge when
original packaging is lost or damaged
5190-1414
GAS MANAGEMENT
In-Line Gas Traps
The purpose of gas traps is to remove detrimental impurities from carrier and detector gases. Combination
traps are available which remove moisture, oxygen, and/or organics with a single trap. The effectiveness of
the traps depends on the initial quality of the gas.
Constant exposure of capillary columns to oxygen and moisture, especially at high temperatures, results
in rapid and severe column damage. The use of oxygen and moisture traps for the carrier gas may extend
column life and protect the instrument. Any moisture or oxygen introduced into the gas stream due to a
leak will be removed by the trap until it expires.
Big universal Traps
Big Universal Traps utilize a layered, multi-adsorbent bed packing of the most effective, highest capacity
adsorbent materials available today for the removal of oxygen, moisture, hydrocarbons, carbon dioxide,
and carbon monoxide from helium gas streams. The volume of the various adsorbent materials in the
Big Universal Trap was developed through rigorous testing and evaluation in order to ensure that
breakthrough of the five major contaminant groups occurs as simultaneously as possible as each material
achieves complete saturation.
One Big Universal Trap unit will easily purify the contents of thirteen "K" size cylinders of 99.997% purity
helium to a cumulative level of 100 µg/L of O2, H2O, CO2, CO, and hydrocarbons at a flow rate of up to
8 L/min. All tube fittings are Swagelok stainless steel, fitted with 40 µm stainless steel frits for particulate
control. Maximum pressure is 250 psi.
Big universal trap
Big Universal Traps are more economical than other purifiers, offering nearly three times the capacity.
Big Universal Traps are ideal for any GC or GC/MS application where helium is employed and assurance
of purity is essential. Combining the contents of three individual in-line traps into a single unit reduces the
number of potential leaks and the possibility of aspirating contaminants into the gas stream. A single purifier
also simplifies installation and replacement.
TiPS & TOOLS
Big universal traps have nearly three
times the capacity of other purifiers.
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
101
GAS MANAGEMENT
capacity Data
high Purity helium-99.997%
removal capacity
< 5 mg/L
O2
1.07 L
THC*
< 1 mg/L
20 g
H2O
< 5 mg/L
46 g
*Total Hydrocarbons, analysis limited to three contaminant groups
Effluent concentration
research Grade helium-99.9999%
< 1 mg/L
H 2O
N2
< 0.5 mg/L
H2
< 0.2 mg/L
O2
< 0.5 mg/L
Ar
< 0.1 mg/L
THC*
< 0.1 mg/L
Ne
< 0.5 mg/L
CO+CO2
< 0.1 mg/L
Impurities
< 0.2 mg/L
*Total Hydrocarbons, analysis limited to three contaminant groups
Big universal Traps (rMS Series)
Description
1/8 in
Part No.
1/4 in
Part No.
Hydrogen
RMSHY-2
RMSHY-4
Helium (Ar/Me)
RMSH-2
RMSH-4
Nitrogen
RMSN-2
RMSN-4
UMC-5-2
UMC-5-2
Trap Mounting clips
Big Mounting Clip, 2/pk
102
GAS MANAGEMENT
Big Traps
• Pressure: Up to 250 psig
• 750 cm3 gas purifiers
• Ideal for bulk purification applications or where several instruments are plumbed
from a single gas source
• One piece of heavy-walled aluminum tube eliminates potential leaks
• Equipped with sintered stainless steel frits to prevent particulate contamination
Big moisture trap
Big Moisture Traps (BMT Series)
Description
capacity
Efficiency
1/8 in
1/4 in
Part No. Part No.
Big Moisture Trap
130 g H2O
Reduction of H2O to less than 5 µg/L
BMT-2
BMT-4
Mounting clips
Big Mounting Clip, 2/pk
UMC-5-2 UMC-5-2
Big Oxygen Traps (BOT Series)
Description
Big Oxygen Trap
capacity
3 L O2
or 3.2 g
Efficiency
1/8 in
1/4 in
Part No. Part No.
Reduction of O2 to less than 1 µg/L
BOT-2
BOT-4
Trap Mounting clips
Big Mounting Clip, 2/pk
UMC-5-2 UMC-5-2
Big hydrocarbon Traps (BhT Series)
Description
Big Hydrocarbon Trap
capacity
80 g of
medium to
heavy
molecular
weight
hydrocarbons
Efficiency
Reduction of C4 hydrocarbons
to less than 15 µg/L
1/8 in
1/4 in
Part No. Part No.
BHT-2
BHT-4
Mounting clips
Big Mounting Clip, 2/pk
UMC-5-2 UMC-5-2
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
103
GAS MANAGEMENT
indicating Moisture Traps
This is an advanced-design gas filter for applications requiring high-efficiency moisture removal with the
benefit of a depletion indicator. The adsorbing materials are Molecular Sieve 5Å and cobalt-free indicator,
held in a sturdy glass tube. The gas to be purified contacts only glass, metal and the absorbent.
The indicator changes color from greenish-yellow to blue at about 5% relative humidity to signal leaks in the
system; the molecular sieve removes moisture to trace levels. The glass tube is sealed with a special dual
sealing system for extra protection from leaks. An internal frit at each end prevents particulate
contamination. The inner glass tube in the Moisture Trap is enclosed in a plastic outer tube for safety.
Dimensions: 3.5 cm x 26 cm, maximum pressure 6.8 bar (100 psig).
Dual Seal Design: In this design the glass inner tube is protected by a sealed outer plastic tube. Even if the
glass tube fails, the gas system is fully protected against leaks.
Description
1/8 in
Part No.
Glass Indicating Moisture Trap
5182-9211 5182-9411
Glass Indicating Moisture Trap
104
1/4 in
Part No.
GAS MANAGEMENT
indicating Oxygen Traps
This is an improved, compact indicating filter for high-efficiency oxygen removal, suitable for use with
chromatography carrier gas streams. It removes oxygen to low-ppb levels, with an indicator that changes
color from green to gray when adsorption capacity is depleted. The adsorbent forms copper oxide in the
presence of oxygen; no gas is generated.
The Glass Indicating Oxygen Trap is recommended as a downstream indicator for high-capacity traps. It can
be used with non-oxidizing gases such as He, Ar, N2, H2 or CH4, with maximum recommended flow rate of
150 cc/min. The absorbents are held in a heavy-walled inner glass tube, shielded by an outer clear plastic
tube for increased safety. Maximum pressure is 6.8 bar (100 psig). Approximate dimensions are 3.5 cm x
26 cm including fittings.
Dual Seal Design: In this design the glass inner tube is protected by a sealed outer plastic tube. Even if the
glass tube fails, the gas system is fully protected against leaks.
Description
1/8 in
Part No.
1/4 in
Part No.
Glass Indicating Oxygen Trap
5182-9201 5182-9401
Glass Indicating Oxygen Trap, Stainless Steel Fitting
5182-9202 5182-9402
Glass Indicating Oxygen Trap
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
105
GAS MANAGEMENT
Oxygen Traps
• Reduces oxygen to less than 1 µg/L
• Environmentally safe
This trap removes the oxygen rather than converting it to another form of contamination.
Description
Size (cc)
1/8 in
1/4 in
Part No. Part No.
Economy Non-indicating Oxygen Traps (OT1 Series)
Economy non-indicating oxygen trap
Oxygen Trap
70
OT1-2
OT1-4
MC-1
MC-1
Trap Mounting clips
Mounting clip for OT1 traps
hydrocarbon Traps
hydrocarbon Traps
Description
Size (cc)
1/8 in
1/4 in
Part No. Part No.
Hydrocarbon Trap
200
HT200-2
HT200-4
Capillary Grade Hydrocarbon Trap
100
HT3-2
HT3-4
MC-1
MC-1
Mounting clips
Hydrocarbon trap, HT200-2
106
Mounting clip for HT200 Series
GAS MANAGEMENT
Ability of Activated carbon to remove Substances from Gases
using hydrocarbon Traps
compound
Efficiency
compound
Efficiency
acetone
excellent
dissolved oils
excellent
hypochlorous acid
excellent
nitrobenzenes
excellent
alcohol
excellent
nitrotoluene
excellent
amines
very good
ethyl acetate
excellent
inorganic acids
none
ethyl alcohol
excellent
ammonia
poor
organic acids
excellent
iodine
excellent
ethyl chloride
excellent
amyl acetate
excellent
oxalic acid
excellent
isopropyl acetate
excellent
ethyl ether
excellent
amyl alcohol
excellent
ozone
excellent
isopropyl alcohol
excellent
fluoride
poor
benzene
excellent
phenol
excellent
ketones
excellent
formaldehyde
poor
butyl acetate
excellent
potassium permanganate
excellent
butyl alcohol
excellent
propyl acetate
excellent
lactic acids
excellent
glycol
excellent
by-products-organic
very good
propyl alcohol
excellent
lysol
excellent
propyl chloride
excellent
calcium hypochlorite
excellent
hydrogen bromide
satisfactory
mercaptans
excellent
hydrogen chloride
poor
carbon dioxide
none
sodium hypochlorite
excellent
methyl acetate
excellent
hydrogen fluoride
none
chlorobenzene
excellent
solvents
excellent
methyl alcohol
excellent
hydrogen iodide
satisfactory
chlorine
excellent
sulfuric acid
satisfactory
methyl bromide
excellent
hydrogen selenide
satisfactory
chlorophenol
excellent
hydrogen sulfide
satisfactory
methyl chloride
excellent
toluene
excellent
chlorophyl
excellent
trichloroethylene
excellent
methyl ethyl ketone
excellent
xylene
excellent
cresol
excellent
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
107
GAS MANAGEMENT
combination Traps
Oxygen/Moisture Traps
Oxygen/moisture adsorbents team up to give you two functionalities in the same trap. Unlike some
oxygen/moisture traps, these traps are disposable.
Consider the safety, performance, and cost advantages of Agilent capillary-grade oxygen/moisture traps
(OT3) compared to heated, catalytic traps.
• Optimized for maximum surface area and capacity
• Leak-free, one-piece design (tested to 2000 psi)
• Bed material treated with ultra-high purity helium
• Filter design: prevents channeling, promotes efficient scrubbing
In addition to inert gases (nitrogen, helium, argon, and krypton), the Agilent OT3 Trap treats streams of
hydrogen, alkanes, alkenes, aliphatic hydrocarbon gases, low boiling aromatics, carbon dioxide, carbon
monoxide, and argon-methane.
Oxygen/Moisture Traps (OT3 Series)
Agilent OT3 trap
Description
capacity
Efficiency
Size
(cc)
1/8 in
1/4 in
Part No. Part No.
OT3 Trap
500 mL O2
2 g H2O
< 15 µg/L
100
OT3-2
OT3-4
MC-1
MC-1
Trap Mounting clips
Mounting clip
hOw DOES iT wOrK?
The Agilent OT3 Trap contains a highly active, metal-containing, scrubbing material in an inert, aluminum body.
108
GAS MANAGEMENT
hydrocarbon/Moisture Traps
• Replace most mixed bed traps supplied by GC manufacturers
• Mounting panel
Hydrocarbon/Moisture trap
hydrocarbon/Moisture Traps (hMT Series)
Description
1/8 in
Part No.
Size (cc)
Hydrocarbon/Moisture Trap
200
1/4 in
Part No.
HMT200-2 HMT200-4
Mounting clips
Mounting clip
MC-1
MC-1
combination Traps for chemical ionization MS
Description
Fitting (in)
Chemical Ionization for MS*
1/8
Part No.
G1999-80410
*Isobutane or methane applications only
Universal/External Split Vent Trap
• Protects lab from contaminants released by split injection systems
• Stops environmental pollution by trapping and eliminating a broad range of contaminants
• Easy to change
• Comes with three packs of replacement cartridges
Split vent trap and cartridges, RDT-1020
universal/External Split Vent Trap
Description
Part No.
Universal/external split vent trap with 3 cartridges, 1/8 in Swagelok fitting
RDT-1020
Replacement cartridges, 3/pk
RDT-1023
TiPS & TOOLS
Remember to replace split vent
cartridge every six months.
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
109
GAS MANAGEMENT
ADM Flow Meters
ADM flow meters allow most gas measurements with the touch of only one button – turn it on, and the
instrument provides continuous, hands-free flow readings. Measure column, detector, and carrier gas flows
without making any adjustments. ADM flow meters are ideal for measuring gas streams with a changing
gas composition. For example, if gas flow is measured from a digestion system, concentration changes in
methane, carbon dioxide, and oxygen will not affect accuracy.
All ADM flow meters are battery powered and field-portable. Agilent calibrates each instrument to 5-point,
NIST-traceable standards to ensure the highest available accuracy. The ADM family measures flow
volumetrically, so you don’t have to make adjustments when changing from one gas to another.
ADM 1000
• Accuracy ± 3%
• Operating temperature range – 0 to 45 °C for the instrument, -70 to 135 °C for the tubing
• Calibration – traceable to NIST primary standards
• Real-time, split ratio measurement
• CE mark certified
• Measures flow rates from 0.5 to 1000 mL/min
• Split ratios – compare the ratio from one gas measurement to another (i.e., injection port split ratios)
ADM 1000
ADM 2000
In addition to the features of the ADM 1000, the ADM 2000 includes:
• Mass flow measurements – measure flow rate, independent of atmospheric pressure and temperature
(calculated)
• Data output through RS-232 port
• 9 V battery and AC power adapter (120 or 220 VAC)
ADM 2000
ADM Flow Meters
Flow rate (mL/min)
Description
Low
high
Gases
Measured*
Accuracy (%)
Power
Supply
rS-232
Data Output
Part No.
ADM 1000**
0.5
1000
All
±3
9 V Battery
None
220-1170
ADM 2000**
0.5
1000
All
±3
Battery or 120 VAC
Yes
220-1171-U
ADM 2000E**
0.5
1000
All
±3
AC Adapter, 220 V
Yes
220-1171-E
Carrying Case for ADM
*± 3% or ± 0.2 mL/min, whichever is greater with a flow rate of 0.5-1,000 mL/min
**Non-corrosive gases only
110
907-0056
GAS MANAGEMENT
Flow Meters
Precision Gas Flow Meter
Agilent's Precision Gas Flow Meter is the ultimate gas flow meter for chromatography applications.
This handheld flow meter is highly accurate, reliable and incorporates industry leading performance.
The inherent stability of the rugged, solid state components allows Agilent to provide the longest
calibration interval on the market, all traceable to NIST standards.
Precision gas flow meter, 5067-0223
• Highly accurate and reliable measurement of common carrier and fuel gases used in GC, including
nitrogen, air, carbon dioxide, hydrogen, helium, and argon/methane
• Two year guaranteed calibration period traceable to NIST standards
• Measures flow based on gas viscosity properties with an accuracy of ± 0.8% of reading + 0.2%
of full scale
• Flow rate range from 5 to 500 mL/min
• Displays mass flow, volumetric flow, temperature, and pressure readings simultaneously
• Can be plumbed inline
Precision Gas Flow Meter
Description
Part No.
Precision gas flow meter
5067-0223
TiPS & TOOLS
Ensure you are maximizing the inertness of your GC flow path with the Agilent Ultra Inert Poster – www.agilent.com/chem/uiorder
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
111
GAS MANAGEMENT
Gas Leak Detector
Gas leaks can cause detector noise and baseline instability, shorten column life and waste expensive carrier
gas. Liquid leak detectors, although inexpensive, can contaminate your system. Agilent's G3388B Electronic
Gas Leak Detector is an easy way to quickly identify leaks in your system and prevent system downtime.
Gas leak detector, G3388B
• Detects thermal conductivity differences
• Audible and visual alerts
• Minimum detection limit – 0.0005 mL/min hydrogen and helium
• Lightweight – only 105 g
• Small – roughly 50 (w) x 19.5 (d) x 111 (h) mm
• Rechargeable Lithium Ion Battery with over 5 hours of life
• Includes a USB cable for battery charging
• One year warranty from Agilent
Gas Leak Detector
Description
Part No.
Handheld electronic gas leak detector
G3388B
G3388A replacement Parts
Description
Part No.
Replacement filter tip
5067-0218
Replacement battery
5067-0219
Replacement power supply
5067-0220
TiPS & TOOLS
For more information about the Gas Leak Detector, visit www.agilent.com/chem/leakdetector
112
GAS MANAGEMENT
Gas Cylinder Regulators, U.S. Only
To plumb your system properly, select one of Agilent’s economical brass regulators and the proper gas
purification devices from our newly expanded product offering. These regulators and our broad spectrum of
in-line filters, combination traps, and gas purification systems are an excellent combination to plumb your
systems. Our new gas purification selection guide and diagrams will help you determine which products can
be used with the regulators below.
Brass Body, Dual Stainless Steel Diaphragms
Brass body regulator
Specifications
Max inlet pressure
3000 psig
Operating temperature range
-40 °F to 165 °F
Inlet-outlet port
1/4 in, MNPT
Outlet valve
1/4 in, MNPT
2 1/2 in dual-scale gauges
CGA-346, 350, 340, 580, 590
Internal self-reseating relief valve
Delivery pressures
1 to 125 psig
Weight
5.6 lb
Materials of construction
Gauges: Brass
Body: Brass
Diaphragms: Stainless steel
Outlet needle valve: Brass
Bonnet: Brass
Seat assemblies: Encapsulated
Adjusting knob
Seat material: PTFE
www.AGiLENT.cOM/chEM/GENErALSuPPLiES
113
GAS MANAGEMENT
Brass Body, Two-Stage Stainless Steel Diaphragms, 1/8 in, u.S. Only*
Description
Part No.
CGA 346, 125 psig max (8.6 bar), Breathing Air
5183-4641
CGA 350, 125 psig max (8.6 bar), H2, Ar/Me
5183-4642
CGA 540, 125 psig max (8.6 bar), O2
5183-4643
CGA 580 Regulator, 125 psig max (8.6 bar), He, Ar, N2
5183-4644
CGA 590, 125 psig max (8.6 bar), Industrial Air
5183-4645
*For 1/4 in tubing, purchase a 1/4 in adapter, U.S. only
Connector (Swagelok-style to female NPT),
0100-0118
connectors (Swagelok to Female NPT)
Description
unit Part No.
1/8 in (A) x 1/4 in (B) connector, brass (included with brass regulators)
1/ea 0100-0118
1/4 in (A) x 1/4 in (B) connector, brass*
1/ea 0100-0119
PTFE tape, industrial roll
0460-1266
*Required for plumbing 1/4 in tubing to regulators
Connector (Swagelok-style to female NPT),
0100-0119
Cylinder wall bracket, 5183-1941
114
cylinder wall Bracket
Description
Part No.
Cylinder wall bracket with strap & chain
(cylinder size up to 14 in, 35 cm)
5183-1941
KITS, FITTINGS, TOOLS AND ACCESSORIES
Kits, Fittings, Tools and Accessories
GC Installation Kits
Agilent Installation Kits for GC are designed to provide you with the essential items necessary
for a successful installation while providing a substantial cost saving over individual purchases.
GC Installation Kit with Gas Purifiers
Description
Gas Clean Filters
Unit
GC Installation Kit with Gas Purifiers
Part No.
19199N
Gas Clean Filter Kit, 1/8 in
CP736530
Snoop, 8 oz (236 mL) bottle
9300-0311
1/8 in brass nut and ferrule set
20/pk 5080-8750
Copper tubing, 1/8 in, 50 ft
5180-4196
1/8 in tee, brass
2/pk
5180-4160
1/8 in cap, brass
6/pk
5180-4121
Universal/external split vent trap with 3 cartridges
RDT-1020
Tubing Cutter
8710-1709
Low dead volume tee, 5180-4160
1/8 in brass cap, 5180-4121
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
115
KITS, FITTINGS, TOOLS AND ACCESSORIES
GC Installation Kit with Tools (no gas purifiers)
Description
Unit
GC Installation Kit with Tools (no gas purifiers)
19199M
Snoop, 8 oz (236 mL) bottle
9300-0311
1/8 in brass nut and ferrule set
20/pk 5080-8750
Copper tubing, 1/8 in, 50 ft, precleaned
5180-4196
1/8 in tee, brass
GC Installation Kit with Tools (no gas purifiers),
19199M
Part No.
2/pk
5180-4160
6/pk
5180-4121
Tubing cutter, 1/8 to 5/8 in od tubing
8710-1709
1/8 in cap, brass
Nut driver, 7 mm
8710-1217
Screwdriver, Torx T10
5182-3466
Screwdriver, Torx T20
5182-3465
Open end wrench, 1/4 and 5/16 in
8710-0510
Open end wrench, 7/16 and 9/16 in
8710-0803
Open end wrench, 7/16 and 3/8 in
8710-0972
Wrench, 1/2 and 7/16 in
8710-0806
GC Basic Installation Kit
Description
Part No.
GC Basic Installation Kit
Includes copper tubing, column nuts, a gas trap for the carrier gas, and five wrenches
5182-3453
Tubing
Description
OD (in)
ID (mm)
Length Part No.
Precleaned Copper tubing
1/8
2.1
50 ft
5180-4196
12 ft
5021-7107
Precleaned Copper tubing
1/4
4.83
Precleaned Copper tubing
1/8
2.1
Copper tubing
1/16
3.25
50 ft
AL30509
Pretreated 316 stainless steel tubing
1/8
2.1
25 m
CP4026
20 ft
7157-0210
Pretreated 316 stainless steel tubing
Pretreated 316 stainless steel tubing
10 m
CP4025
Pretreated 316 stainless steel tubing
5m
CP4024
Pretreated 316 stainless steel tubing
1/4
4.3
Pretreated 316 stainless steel tubing
Pretreated 316 stainless steel tubing
PFA tubing
116
3700014600
1/16
0.76
25 m
CP4032
5m
CP4030
1m
CP4013
25 ft
AL45734
KITS, FITTINGS, TOOLS AND ACCESSORIES
Fittings
Nuts, Front and Back Ferrule Sets
Description
Unit
1/16 in
10/pk
Brass
Stainless Steel
1/8 in
20/pk
5080-8750
5080-8751
1/4 in
20/pk
5080-8752
5080-8753
Description
Unit
Brass
Stainless Steel
1/16 in, male nut
10/pk
SWB1021
5180-4102
1/16 in
1/ea
1/8 in
10/pk
5180-4103
5180-4104
1/8 in
1/ea
0100-0058
0100-0057
1/4 in
10/pk
5180-4105
5180-4106
Description
Unit
Brass
Stainless Steel
1/16 in
10/pk
1/4 in
1/ea
1/16 in, Valco one piece
10/pk
1/8 in
10/pk
5180-4109
5180-4110
1/4 in
10/pk
5180-4111
SWSS4031
5180-4149
Brass nut and ferrule set, 5080-8750
Nuts
Stainless steel front ferrules, 5180-4108
0100-0053
Front Ferrules
Front ferrules, stainless steel, 5181-1292
5180-4108
2869463500
5181-1292
Front ferrules, 5180-4109
Front ferrules, 5180-4111
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
117
KITS, FITTINGS, TOOLS AND ACCESSORIES
Back Ferrules
Back ferrules, 5180-4115
Description
Unit
Brass
Stainless
Steel
1/16 in
10/pk
5180-4113
5180-4114
1/8 in
10/pk
5180-4115
5180-4116
1/4 in
10/pk
5180-4117
SWSS4041
Description
Unit
Brass
1/8 in
6/pk
5180-4121
1/4 in
6/pk
5180-4120
Description
Unit
Brass
1/8 in
6/pk
5180-4124
1/8 in
1/ea
0100-0071
1/6 in
1/ea
0100-1315
1/4 in
6/pk
5180-4125
Caps
Back ferrules, 5180-4117
Plugs
1/8 in brass cap, 5180-4121
1/4 in brass cap, 5180-4120
1/8 in plug, 5180-4124
1/4 in plug, 5180-4125
118
KITS, FITTINGS, TOOLS AND ACCESSORIES
Blanking Nut
Description
Unit
Stainless Steel
1/16 in
1/ea
01080-83202
Stainless steel blanking nut, 01080-83202
Adapter
Description
Unit
Brass
1/8 in x 1/8 in
1/ea
0100-0420
Brass adapter, 0100-0420
Hose Connector
Description
Unit
Brass
1/16 in
10/pk
5180-4148
Description
Unit
Brass
Stainless
Steel
1/16 in
1/ea
0100-0680
0100-0782
1/8 in
1/ea
0100-0090
0100-0542
2/pk
5180-4160
Tees
1/8 in, for O2 gas mix
1/ea
1/4 in
1/ea
0100-0088
2/pk
5180-4129
1/6 in, low dead volume
1/ea
Low dead volume tee, 0100-0782
0100-0542
0100-0089
0100-0969
Stainless steel tee, 0100-0542
Low dead volume tee, 5180-4160
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
119
KITS, FITTINGS, TOOLS AND ACCESSORIES
Crosses
Description
Unit
Brass
1/8 in
1/ea
0100-0161
1/8 in
1/ea
0100-0996
1/4 in
1/ea
0100-0985
Description
Unit
Brass
1/8 in
1/ea
0100-0091
1/8 in
1/ea
0100-0092
Unit
Brass
Stainless
Steel
0100-0124
Brass cross, 0100-0161
Elbows
Brass cross, 0100-0985
Unions
Description
1/16 in
1/ea
0100-1316
1/8 in
2/pk
5180-4127
1/4 in
2/pk
Brass union, 0100-1316
1/ea
0100-0126
5180-4128
1/ea
0100-0128
Description
Unit
Stainless
Steel
1/16 in
1/ea
0100-0900
Zero Dead Volume Unions
Stainless steel union, 0100-0124
Bulkhead Unions
1/8 in brass union, 5180-4127
1/4 in brass union, 5180-4128
ZDV union with fittings, 0100-0900
120
Description
Unit
Brass
Stainless
Steel
1/8 in
1/ea
0100-0132
0100-0133
KITS, FITTINGS, TOOLS AND ACCESSORIES
Connectors (Swagelok to Male NPT)
Description
Unit
1/16 in (A) x 1/4 in (B)
1/ea
Brass
Stainless
Steel
CP741648
1/8 in (A) x 1/4 in (B)
2/pk
5180-4143
1/8 in (A) x 1/8 in (B)
1/ea
0100-0110
0100-0111
1/4 in (A) x 1/4 in (B)
1/ea
0100-0208
0100-1189
2/pk
5180-4145
Connector (Swagelok-style to male NPT),
5180-4143
Connectors (Swagelok to Female NPT)
Description
Unit
Brass
Stainless
Steel
1/8 in (A) x 1/4 in (B)
1/ea
0100-0118
SWSS20074
1/4 in (A) x 1/4 in (B)*
1/ea
0100-0119
Connector (Swagelok-style to male NPT),
5180-4145
*Required for plumbing 1/4 in tubing to regulators
Connector (Swagelok-style to female NPT),
0100-0118
Reducing Unions
Description
Unit
Brass
1/16 in x 1/8 in
2/pk
5180-4130
1/8 in x 1/4 in
2/pk
1/ea
1/ea
Stainless
Steel
0100-0241
Connector (Swagelok-style to female NPT),
0100-0119
5180-4131
0100-0121
Reducing union, 5180-4130
Reducing union, 5180-4131
Reducing union, 0100-0241
Reducing union, 0100-0121
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
121
KITS, FITTINGS, TOOLS AND ACCESSORIES
Reducers
Description
Reducer, 5180-4135
Unit
Brass
5180-4135
1/8 in (A) x 1/4 in (B)
2/pk
1/6 in (A) x 1/8 in (B)
1/ea
1/4 in (A) x 1/8 in (B)
2/pk
Stainless Steel
0100-0073
5180-4134
Fittings Kit
1/8 in brass cap, 5180-4121
Description
1/8 in nut, brass
Reducer, 5180-4134
1/8 in plug, 5180-4124
Front ferrules, 5180-4109
1/8 in brass union, 5180-4127
Front ferrules, 5180-4111
1/4 in brass union, 5180-4128
Back ferrules, 5180-4115
Low dead volume tee, 5180-4160
1/4 in brass cap, 5180-4120
122
Unit
Fittings Kit: Includes items below
Part No.
5180-4161
10/pk 5180-4103
1/4 in nut, brass
10/pk 5180-4105
1/8 in front ferrule, brass
10/pk 5180-4109
1/4 in front ferrule, brass
10/pk 5180-4111
1/8 in back ferrule, brass
10/pk 5180-4115
1/4 in back ferrule, brass
10/pk 5180-4117
1/4 in cap, brass
6/pk
5180-4120
1/8 in cap, brass
6/pk
5180-4121
1/8 in plug, brass
6/pk
5180-4124
1/4 in plug, brass
6/pk
5180-4125
1/8 in union, brass
2/pk
5180-4127
1/4 in union, brass
2/pk
5180-4128
1/8 in tee, brass
2/pk
5180-4160
1/4 in tee, brass
2/pk
5180-4129
1/8 x 1/4 in reducing union, brass
2/pk
5180-4131
1/4 in (A) x 1/8 in (B) reducer, brass
2/pk
5180-4134
1/8 in (A) x 1/4 in (B) reducer, brass
2/pk
5180-4135
KITS, FITTINGS, TOOLS AND ACCESSORIES
Tools
General Laboratory Tool Kit
The general laboratory tool kit includes the following items:
• Toolbox
• Flashlight
• 8 in bastard file
• 6 in adjustable wrench
• 12 in adjustable wrench for use with regulator
• No. 1 pt, 3 in Pozidriv shaft, fits no. 2-4 screws
• No. 2 pt, 4 in Pozidriv shaft, fits no. 5-10 screws
• Flathead screwdriver, 2 in steel shaft, 1/8 in blade
• Flathead screwdriver, 4 in steel shaft, 1/4 in blade
• Hex key set, 1.5, 2, 2.5, 3, 4, 5, and 6 mm keys
Description
Part No.
General laboratory tool kit
5180-4162
• 6 in long jaw needle nose pliers with side cutters
• Three open-end wrenches
(1/4 x 5/16 in, 1/2 x 9/16 in, 7/16 x 3/8 in)
• Snoop-liquid leak detector
• PTFE tape
Wrenches
Description
Part No.
Open end wrench, 1/4 and 5/16 in
8710-0510
Wrench, 1/2 and 7/16 in
8710-0806
Open end wrench, 7/16 and 9/16 in
8710-0803
Open end wrench, 7/16 and 3/8 in
8710-0972
Adjustable wrench, 12 in, for use with regulators
8710-1712
Open end wrench, 9/16 and 5/8 in
8720-0010
Open end wrench, 1/2 and 9/16 in
8720-0025
Open end wrench, 14 mm
8710-1924
Open end wrench, 12 mm, 116 mm long
8710-1841
Open end wrench, 4 mm
8710-1534
General laboratory tool kit, 5180-4162
LC Tool Kits
Description
Part No.
HPLC system tool kit
G4203-68708
Compact tool kit
G4296-68715
Screwdrivers
Description
Part No.
Screwdriver, 3 in Pozidriv shaft No. 1 pt
8710-0899
Screwdriver, 4 in Pozidriv shaft No. 2 pt
8710-0900
Screwdriver, Torx T10
5182-3466
Screwdriver, Torx T20
5182-3465
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
HPLC system tool kit, G4203-68708
123
KITS, FITTINGS, TOOLS AND ACCESSORIES
Pliers and Tweezers
Description
Part No.
Needle nose pliers, pointed serrated jaws
8710-0004
Tweezers, 4-3/4 in long
8710-0007
Truarc pliers
8710-0018
Tube Cutters and Replacement Blades
Description
Unit Part No.
Precision tubing cutter for 1/16 in stainless steel tubing
5190-1442
Hi-duty tubing cutter, 1/8 to 1-1/8 in od tubing
8710-1707
Hi-duty tubing cutter blades
Tubing cutter, 1/8 to 5/8 in od tubing
Plastic tubing cutter
Blades for plastic cutter, 5/pk
5/pk 8710-1708
8710-1709
8710-1930
5/pk 8710-1931
Plastic tubing cutter, 8710-1930
Hex Keys
Description
Hex keys, Rheotool, 5064-8211
Hex key set: 1.5, 2, 2.5, 3, 4, and 5 mm keys, 1090A (5880/90A)
8710-0641
Hex key, 4 mm, 15 cm long, T-handle
8710-2392
Hex key, 3 mm, 12 cm long, straight handle
8710-2411
Hex key, 2.5 mm, 15 cm long, straight handle
8710-2412
Hex key, 1.5 mm, 10 cm long, straight handle
8710-2393
Hex key, 9/64 in, 15 cm long, T-handle
8710-2394
Hex key, 4.0 mm, 10 cm long, straight handle
5965-0027
Hex key, 2.5 mm, 10 cm long, straight handle
5965-0028
Tool kit hex keys, Rheotool*
Includes 3 hex keys, 4 mm, 1.5 mm, and 9/64 in, with straight or T-handle plus Rheotool
5064-8211
*These tools are recommended for easier repair and maintenance of LC modules.
124
Part No.
KITS, FITTINGS, TOOLS AND ACCESSORIES
GC Column Accessories
Capillary Column Installation Kit
The Capillary Column Installation Kit contains:
• Diamond-tipped pencil
• 20x magnifier
• Ferrule removal tool
• Septum removal tool
• Refillable 2 oz bottle of Snoop
Description
Part No.
Capillary Column Installation Kit with diamond-tipped cutting pencil
430-2000
Column installation kit, 430-2000
Capillary Column Rinse Kit
This kit makes solvent rinsing easy! Solvent rinsing removes many contaminants that accumulate in
columns. The contaminants are removed by passing solvents through the column. Only bonded and
cross-linked phase columns should be rinsed, or permanent damage to the column will result.
Description
Part No.
Capillary Column Rinse Kit
430-3000
Column rinse kit, 430-3000
TIPS & TOOLS
View the latest Agilent J&W GC column focused applications, products and educational resources
at www.agilent.com/chem/mygccolumns
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
125
KITS, FITTINGS, TOOLS AND ACCESSORIES
Fused Silica Tubing Cutters
We offer a conveniently designed, pencil-shaped tool and a ceramic wafer that allow you to make clean
and easy cuts in fused silica, glass and aluminum-clad capillary columns.
Description
Fused silica tubing cutters
Diamond-tipped column cutting pencil
420-1000
Ceramic wafer column cutter, 4/pk
5181-8836
Column cutter with rotating diamond blade
5183-4620
Replacement diamond blade (for 5183-4620)
5183-4621
Column Baskets and Hangers
Description
Column cutting tool, 5183-4620
126
Part No.
Part No.
13 cm, 5 in basket for 6850 capillary columns
19091-80060
Column hanger for 5 in basket
G2630-80800
Column hanger clip kit for 7 in basket
G1530-61580
Column hanger for 6890, 5890, 5880A
1460-1914
KITS, FITTINGS, TOOLS AND ACCESSORIES
Miscellaneous Tools
Ferrule Tools
Remove ferrules stuck inside fittings. Screw the stainless steel ferrule tool into the ferrule and pull it
out. Use the smaller capillary ferrule tool for capillary column ferrules (0.32 mm id column and smaller).
The megabore ferrule tool is used for megabore ferrules. The liner tool can be used to remove polyimide
and tubing from inside a megabore liner. The column ferrule installation tool positions a ferrule onto a
capillary column for proper installation.
Description
Part No.
Capillary ferrule tool
RFT-2500
Megabore ferrule tool
RFT-5300
Column ferrule installation tool
19251-80680
MS interface column installation tool
G1099-20030
Capillary and megabore ferrule tool
20x Magnifier
Examine column ends for proper cuts. Jagged, rough, or non-perpendicular cuts negatively affect
chromatographic performance.
Description
Part No.
20x Magnifier
430-1020
Microprobes
Hardened stainless steel probes remove septum and ferrule pieces stuck in fittings. Five different styles
give you all of the angles necessary for getting into those hard-to-reach places.
Magnifier, mirror, microprobes
Description
Part No.
Microprobes
RMP-5005
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
127
KITS, FITTINGS, TOOLS AND ACCESSORIES
Mirror
Inspect injection ports, the inside of fittings, and other hard-to-reach places.
Description
Part No.
Mirror
707-0027
Snoop
Leak test most pressurized gas systems. We recommend that leak detecting solutions be used with care
where there is any possibility of the fluid being aspirated into gas flow streams supplying the column or
detector. This squeezable bottle comes with a “Snooper Tube” extendable up to 12 in (30 cm). Electronic
leak detectors are preferred. In their absence, a volatile nonreactive solvent like isopropanol may be used.
Use caution to avoid aspiration of materials such as Snoop into the column.
Description
Part No.
Snoop, 8 oz (236 mL) bottle
9300-0311
Snoop, 1 gallon bottle
460-1002
Snoop
Injection Port Cleaning Kit
If changing the liner and trimming the column does not remove contamination from your injection port, you
probably need to clean and flush your injection port. Three stainless steel brushes and a scraper are the
ideal tools for removing sample residue and septum particles. The stainless steel brushes have diameters of
5 mm, 1/4 in, and 3/8 in.
Injection port cleaning kit, 480-0003
Description
Part No.
Injection Port Cleaning Kit
480-0003
Miscellaneous Injection Port Tools
Septum tool with knurled handle, 450-1000
Capillary inlet cleaning wires, 5180-4153
128
Description
Part No.
Septum tool, knurled handle
450-1000
Ferrule removal tool
440-1000
Capillary inlet cleaning wires, 5/pk
5180-4153
Cotton swabs, 100/pk
5080-5400
KITS, FITTINGS, TOOLS AND ACCESSORIES
FID Cleaning Kit
This easy-to-use maintenance kit improves sensitivity, reduces noise, and decreases detector spiking.
Description
Part No.
FID cleaning kit
9301-0985
FID cleaning kit, 9301-0985
12-Piece File Set
This 12-piece file set scores glass, removes burrs from metal tubing, and cleans threads. The files are
5-1/2 in long.
Description
Part No.
12-Piece File Set
RSF-1200
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
129
ELECTROCHEMISTRY
Electrochemistry Meters,
Electrodes, and Solutions
Analyst-friendly features optimize your measurements
and ensure accuracy
3200P standard pH meter, G4383A
User-friendly control panel simplifies
your measurements and ensures
accurate results, regardless of
technical knowledge or skill level.
Your rapidly changing work environment demands speed and productivity without jeopardizing results.
That is why all Agilent meters and electrodes are designed for easy operation, even by non-technical users,
while still producing the most reliable readings.
• Unique electrode reference system, backed by our qualified material and manufacturing process,
delivers fast, reliable response during meter operation
• Rugged design stands up to the toughest indoor and outdoor conditions
• High-endurance protective glass and multi-layer composite electrodes prevent breakage caused by
frequent use, even in demanding environments
Every Agilent Meter
is backed by our 3-year
replacement guarantee.
3200P pH Meter
3200P pH Meter Specifications*
Specifications
Range
Resolution
Accuracy
3200P standard pH meter, G4383A
3200P
pH
-2.000-20.000 pH
mV
-1999.9-1999.9 mV
Temperature
-5.0-110.0 °C
pH
0.1/0.01/0.001 pH
mV
0.1 mV
Temperature
0.1 °C
pH
±0.002 pH
mV
±0.03% FS
Temperature
±0.1 °C
Temperature compensation
Manual/Auto -5.0-110.0 °C
Power
Universal AC power adapter 100 V-240 V, 50/60 Hz**
Dimension (L×D×H) [mm]
190×190×105
Weight (kg)
1
*EC Print software for easy and direct printing and EC Firmware software are available for free download at
www.agilent.com/chem/phmeters
**Shipped with meter
130
ELECTROCHEMISTRY
3200M Multi-parameter Meter
Simultaneously measure pH/pX, ion concentration, ion electrode potential (mV), conductivity (TDS, salinity),
DO (concentration and saturation), temperature, and more.
3200M Multi-parameter Analyzer Specifications*
Specifications
Range
3200M
pH
-2.000-20.000 pH
pX
0.000-14.000 pX
mV
-1999.9-1999.9 mV
Conductivity
0.000 µS/cm-2000 mS/cm
3200M multi-parameter meter, G4387A
Resistivity
5.00 W.cm-100.0 MW.cm
TDS
0.000 mg/L-1000 g/L
Salinity
0.00%-8.00% (Chinese version)
0.0-80.0 g/L (English version)
DO
0-45.00 mg/L
DO saturation
0.0-300.0%
Ion concentration
0-19990
-5.0-110.0 °C
Resolution
Temperature
-5.0-110.0 °C
pH/pX
0.1/0.01/0.001 pH/pX
mV
0.1 mV
Ion concentration
Four effective digits (Scientific notation)
DO
0.01 mg/L
DO saturation
0.1%
Temperature
0.1 °C
*EC Print software for easy and direct printing and EC Firmware software are available for free download at
www.agilent.com/chem/phmeters
(Continued)
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
131
ELECTROCHEMISTRY
3200M Multi-parameter Analyzer Specifications*
Specifications
Accuracy
3200M
pH/pX
±0.002 pH/pX:pXII:± 0.005 pX
mV
±0.03% FS
Ion concentration
±0.3%
Conductivity
±0.5% FS
Resistivity
±0.5% FS
TDS
±0.5% FS
Salinity
±0.1%
DO
±0.10 mg/L
DO saturation
±2.0%
Temperature
±0.1 °C
Power
Universal AC power adapter
100 V-240 V, 50/60 Hz**
Dimensions (LxDxH) [mm]
Weight (kg)
190×190×105
1
1
*EC Print software for easy and direct printing and EC Firmware software are available for free download at
www.agilent.com/chem/phmeters
**Shipped with meter
Cell Constant and Correspondent Measuring Range
Cell constant
(K) (cm-1)
Measuring range for solutions
132
0.001
0.01
0.1
1.0
10.0
100
0.000 µS/cm1.999 µS/cm
0.000 µS/cm19.99 µS/cm
0.200 µS/cm199.9 µS/cm
2.00 µS/cm19.99 mS/cm
20.0 µS/cm199.9 mS/cm
200 mS/cm2000 mS/cm
ELECTROCHEMISTRY
3200I Ion Meter
When matched with an ion-selective electrode and reference electrode, ion meters can measure
corresponding electrode potential (mv), pX, and ion concentration.
3200I Ion Meter Specifications*
Specifications
Range
Resolution
Accuracy
3200I
pH
pX
0.000-14.000 pX
mV
-1999.9-1999.9 mV
Ion concentration
0-19990
Concentration unit
mol/L, mmol/L, g/L, mg/L, µg/L (Chinese version)
mol/L, mg/L, %, mg/L, µg/L (English version)
Temperature
-5.0-110.0 °C
pX
0.1/0.01/0.001 pH/pX
mV
0.1 mV
Ion concentration
Four effective digit (Scientific notation)
Temperature
0.1 °C
pX
±0.002 pH/pX:pXII: ±0.005 pX
mV
±0.03% FS
Ion concentration
±0.3%
Temperature
Power
-2.000-20.000 pH
3200I ion meter, G4386A
±0.1 °C
Universal AC power adapter 100 V-240 V, 50/60 Hz**
Dimension (L×D×H) [mm]
190x190x105
Weight (kg)
1
*EC Print software for easy and direct printing and EC Firmware software are available for free download at
www.agilent.com/chem/phmeters
**Shipped with meter
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
133
ELECTROCHEMISTRY
3200C Conductivity Meter
Measure conductivity, resistivity, total dissolved solid (TDS), salinity, and present solution temperature.
3200C Conductivity Meter Specifications*
Specifications
Range
3200C conductivity meter, G4384A
Resolution
Accuracy
3200C
Conductivity
0.000 µS/cm-2000 mS/cm
Resistivity
5.00 W.cm-100.0 MW.cm
TDS
0.000 mg/L-1000 g/L
Salinity
0.00%-8.00% (Chinese version)
0.0-80.0 g/L (English version)
Temperature
-5.0-110.0 °C
Conductivity
Four effective digital, and the lowest level is 0.001 µS/cm
Temperature
0.1 °C
Conductivity
±0.5% FS
Resistivity
±0.5% FS
TDS
±0.5% FS
Salinity
±0.1%
Temperature
±0.1 °C
Cell constant
0.001, 0.01, 0.1, 1.0, 10, 100 cm-1
Compensation range of cell constant
±20% of Standard constant value
Temperature compensation range
0-50.0 °C
Conductivity and TDS standard temperature
25.0 °C
Salinity standard temperature
18.0 °C
Power
Universal AC power adapter 100 V-240 V, 50/60 Hz**
Dimension (L×D×H) [mm]
190×190×105
Weight (kg)
1
*EC Print software for easy and direct printing and EC Firmware software are available for free download at
www.agilent.com/chem/phmeters
**Shipped with meter
134
ELECTROCHEMISTRY
3200D Dissolved Oxygen Meter
Membrane electrode measures DO concentration and saturation of water solutions.
3200D Dissolved Oxygen Meter Specifications*
Specifications
Range
Resolution
Accuracy
3200D
DO
0-45.00 mg/L
DO saturation
0.0-300.0%
Temperature
-5.0-110.0 °C
DO
0.01 mg/L
DO saturation
0.1%
Temperature
0.1 °C
DO
±0.10 mg/L
DO saturation
±2.0%
Temperature
3200D dissolved oxygen meter, G4385A
±0.1 °C
Temperature compensation
Automatic: 0.0-45.0 °C
Standard temperature
20±1 °C
Salinity calibration
0.0-50.0 g/L
Barometric pressure calibration
60.0-110.0 kPa
Power
Universal AC power adapter 100 V-240 V, 50/60 Hz**
Dimension (L×D×H) [mm]
190×190×105
Weight (kg)
1
*EC Print software for easy and direct printing and EC Firmware software are available for free download at
www.agilent.com/chem/phmeters
**Shipped with meter
Agilent Electrochemistry Meters:
rigorously evaluated for durability and safety
Our environmental test specifications ensure that Agilent Electrochemistry Meters will be rugged performers
in your lab, just like Agilent columns and instruments.
Environmental Test Specifications
Operating ambient temperature
0-50 °C
Operating relative humidity
5-95%, no condensation
Storage temperature
Meter: -40-70 °C; Electrode: -15-55 °C
Vibration and shock
Instrument test and package test
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
135
ELECTROCHEMISTRY
Module Specifications
Type/Model
Standard pH
Meter (3200P)
Key Industries/Applications
ü Pharmaceutical
ü Food safety
ü Biological agriculture
ü Environmental
ü Water quality
Conductivity Meter ü Environmental
(3200C)
ü Petrochemical
ü Food safety
ü Biological
136
Measurements
Details
ü Acid and alkali levels
ü Electrode potential (mV) values of
relevant ions
ü G4383A for 3200P meter only
ü G4391A for basic package with
electrode, electrode holder and buffer
ü G4392A for kit with triode combination
electrode, electrode holder and buffer
ü Conductivity
ü Resistivity
ü Total Dissolved Solids (TDS)
ü Salinity
ü Present solution temperature value
ü G4384A for 3200C meter only
ü G4393A for package with 3200C meter,
electrode and electrode holder
Dissolved Oxygen
(DO) Meter
(3200D)
ü Environmental
ü Sewage disposal
ü Tap water source monitoring
ü Food safety
ü Aquaculture
ü Beverage production
ü Biological agriculture
ü Scientific research
ü Dissolved oxygen concentration
ü Saturation of water solution
ü G4385A for 3200D meter only
ü G4395A for package with 3200D meter,
electrode and electrode holder
Ion Meter (3200I)
ü Food safety
ü Biological agriculture
ü Petrochemical
ü Environmental protection
ü Scientific research
ü Disease control
ü Electrode potential (mV) values
ü pX value and ion concentration
ü G4396A for 3200I meter only
ü G4396A for package with 3200I meter,
pH electrode, electrode holder and buffer
ü G4397A for fluoride ion package with
3200I meter, fluoride ion electrode and
electrode holder and buffer
Multi-Parameter
Meter (3200M)
ü Water quality
ü Disease control
ü Environmental protection
ü Biological agriculture
ü Scientific research
ü Simultaneously measures pH/pX, ion
concentration, ion electrode potential
(mV), conductivity, Total Dissolved Solids
(TDS), salinity, dissolved oxygen, and
temperature
ü G4378A for 3200M meter
ü G4398A for 3200M meter, electrode,
electrode holder and buffer
ELECTROCHEMISTRY
Module specifications
Agilent provides modules to fit your most challenging applications.
Module
3200P
3200C
3200D
3200I
3200M
Specifications
Benefits
Temperature: -5.0-110.0 °C
Compatible with a wide temperature range
Measuring mode: continuous/timed reading/auto-lock
Lets you perform a variety of measurements with one meter
Dot-matrix LCD
Fast interpretation of results
Easy for novices to use
Numeric operating keys
Simplified operation for all skill levels
3200P
3200I
3200M
Automatic identification for buffers
Choice of NIST and GB buffers
Impedance: 3x1012 W
Choose from a wider range of electrodes for your sample
Accuracy of DO: ±0.10 mg/L
Precise measurements and excellent temperature compensation
provide outstanding DO accuracy
3200I
3200M
Provides Ion measurement modes for H+, Ag+, Na+, K+
NH4+, Cl-, F-, NO3-, BF4-, CN-, Cu2+, Pb2+ and Ca2+
Easily exchanged electrodes (or ISEs) allow flexible multi-ion analysis
Different units can be switched freely
Automatic functions optimize measurements
and ensure accurate results
Measuring mode in ion concentration: direct reading,
"Standard" addition, sample addition, GRAN plot addition
Convenience
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
137
ELECTROCHEMISTRY
Wide range of Agilent electrodes
help meet the needs of any application
Unlike single-layer breathable membrane electrodes, Agilent electrodes are made from multi-layered
composite materials for extra durability. They also feature a specific barrier to protect the glass bubble
against breakage.
What’s more, the unique reference system on every Agilent electrode is backed by our uncompromising
materials quality and manufacturing process – giving you fast response and high accuracy.
The electrodes shown here use universal connections, so you can use them interchangeably on Orion 3 star,
4 star meter, Hanna HI2221, and Mettler FE20pH.
3200EA electrode holder, G4389A
138
P3211 pH combination
electrode, 5190-3988
P3212 pH combination
electrode, 5190-3989
P3214 pH combination
electrode, 5190-3993
P3213 pH combination
electrode, 5190-3992
P3311 pH triode combination
electrode, 5190-3990
P3111 pH electrode,
5190-3991
pH P3211
pH P3212
pH P3214
pH P3213
pH P3311
pH P3111
ü Combination
electrode with
glass body
ü Refillable
ü BNC connector
ü Glass bulb
measuring tip
ü Combination
electrode with
PC body
ü Not refillable
ü BNC connector
ü Glass bulb
measuring tip
ü Combination
electrode with
ABS body
ü Not refillable
ü BNC connector
ü Spear-tipped
measuring tip
ü Combination
electrode with
PC body
ü Refillable
ü BNC connector
ü Flat measuring tip
ü Combination
electrode with
glass body
ü Refillable
ü BNC and miniDIN4
connector
ü Glass bulb
measuring tip
ü Electrode with
glass body
ü Not refillable
ü BNC connector
ü Glass bulb
measuring tip
ELECTROCHEMISTRY
Recommended uses*
pH
P3211
pH
P3212
Milk
3
Soy Sauce
Beer
Soft drinks (ice black tea)
Industry
Sample
Drinks and dairy products
Food and agricultural products
pH
P3214
pH
P3213
pH
P3311
pH
P3111
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Compound fertilizer
3
Jam
3
Meat
Vegetables
3
3
Waste
3
3
3
Chemical reagents
and electrolytes
Electroplate liquid
3
3
Coatings, dyes,
and latex
Suspended solid (soil)
Water
Tap water
3
3
3
3
3
Drinking water (barreled water)
3
(Static)
Distilled water
3
(Sealed)
3
3
3
Drug or biological samples
Protein sample/protein powder
Surface measurement
Droplet size of the sample
3
Textiles
3
Cosmetics and viscous samples
3
Shampoo
3
3
3
Cosmetic paste
3
3
3
*Laboratory test; for reference only
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
139
ELECTROCHEMISTRY
Recommended uses*
ORP8211
Oxygen Reduction Potential (ORP) measurement of:
ü Conventional water
ü Wastewater
ü Electroplate liquid
ü Biological samples
I9111
ü Fluoride water samples
ü Surface water
ü Drinking water
ü Industrial effluent
I9121
ü Ammonium/ammonia-containing water samples
ü River and lake water
ü Tap water
ü Environmental protection/sewage
I9131
ü Conventional sodium water samples
ü Water treatment
ü Power plant
ü Industrial process control
ORP8211 ORP electrode, 5190-3999
*Laboratory test; for reference only
pH Electrode Specifications
Model
P3211
P3212
P3214
P3213
P3311
Measurement range
0-14 pH
0-14 pH
0-14 pH
0-14 pH
0-14 pH
0-14 pH
PTS
≥ 97%
≥ 97%
≥ 97%
≥ 97%
≥ 97%
≥ 98.5%
30s
30s
60s
60s
30s
60s
Response time
140
P3111
Temperature accuracy
–
–
–
–
± 0.5 °C
–
Electrode impedance
≤ 300 MW
≤ 300 MW
≤ 500 MW
≤ 500 MW
≤ 300 MW
≤250 MW
Reference type
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
–
Liquid junction material
Ceramic
Porous polymer
Fiber
Fiber
Ceramic
–
ELECTROCHEMISTRY
ORP8211 ORP electrode,
5190-3999
I9111 Fluoride combination ISE,
5190-4002
I9121 Ammonia combination ISE,
5190-4004
I9131 Sodium combination ISE,
5190-4005
ORP8211
Oxidation Reduction
Potential
I9111
Fluoride Combination ISE
I9121
Ammonia Combination ISE
I9131
Sodium Combination ISE
Combination electrode
with glass body
Refillable
BNC connector
Combination electrode
with PC body
Refillable
BNC connector
Combination electrode
with PMMA body
Refillable
BNC connector
Combination electrode
with glass body
Refillable
BNC connector
Ion Selective Electrode
Specifications
Concentration range
Slope (25 °C)
Response time
I9111
Fluoride Combination ISE
I9121
Ammonia Combination ISE
I9131
Sodium Combination ISE
Saturation: -10-6 mol/L
Saturation: -0.02 mg/L
≥ 56 (10-5-10-1) mol/L
(10-1- 10-6) mol/L
≥ 55 (10-5-10-2) mol/L
Saturation: -10-6 mol/L
≥ 56 (10-5-10-1) mol/L
30s
180s
180s
Internal impedance
≤ 1 MW
≤ 1500 MW
≤ 250 MW
Reference type
Ag/AgCl
Ag/AgCl
Ag/AgCl
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
141
ELECTROCHEMISTRY
ORP8211 Oxidation Reduction Potential Electrode Specifications
Measurement range
± 1999 mV
Potential accuracy
263 ± 10 mV
Reference type
Ag/AgCl
Liquid junction material
Ceramic
R8111 Reference Electrode Specifications
Potential accuracy
± 4 mV
Internal impedance
≤ 1 kW
Reference type
Ag/AgCl
Liquid junction material
Ceramic
Reference filling solution
AgCl, 3 mol/L KCl
T7111 Automatic Temperature Compensation Probe Specifications
Measuring range
0-100 °C
Accuracy
± 0.3 °C 0-60 °C
± 1.0 °C 60-100 °C
D6111 Dissolved Oxygen Probe Specifications
Measuring range
0-20 mg/L
Zero oxygen current
1% FS (5 min)
Response time (90%)
30 s
Temperature accuracy
± 0.5 °C
Conductivity Probe
Specifications
142
C5111
C5112
C5113
Cell constant
1.0 ± 0.2
1.0 ± 0.2
0.1 ± 0.02
Measuring range
2-19990 µS/cm
2-3000 µS/cm
0.2-199.9 µS/cm
Accuracy
± 0.6%
± 0.6%
± 0.6%
ELECTROCHEMISTRY
All-in-one Packages
Description
Agilent 3200P Benchtop pH Meter Basic Package
Includes:
Recommended Use
Part No.
Stable, accurate measurement of organic solution samples in fields
such as scientific research, education, and chemical analysis
G4391A
Agilent 3200P benchtop pH meter
G4383A
Agilent 3200EA electrode holder
G4389A
P3211 pH combination electrode, includes 30 mL reference solution
5190-3988
T7111 ATC probe
5190-3998
pH buffer solutions, 4.01, 7.00, 10.01, NIST traceable, 250 mL, 3/pk
5190-0533*
pH buffer solutions, 4.00, 6.86, 9.18, GB traceable, 250 mL, 3/pk
5190-0534**
Ordinary physical and chemical analysis in fields such as
conventional water quality, education, and chemical analysis
Agilent 3200P Benchtop pH Meter Package
with 3-in-1 Electrode
Includes:
Agilent 3200P benchtop pH meter
G4392A
G4383A
Agilent 3200EA electrode holder
G4389A
P3311 pH triode combination electrode, includes 30 mL reference solution
5190-3990
pH buffer solutions, 4.01, 7.00, 10.01, NIST traceable, 250 mL, 3/pk
5190-0533*
pH buffer solutions, 4.00, 6.86, 9.18, GB traceable, 250 mL, 3/pk
5190-0534**
Agilent 3200C Benchtop Conductivity Meter Basic Package
Includes:
Best for applications such as conventional surface water,
drinking water, environmental water testing, and process analysis
Agilent 3200C benchtop conductivity meter
G4393A
G4384A
Agilent 3200EA electrode holder
G4389A
C5111 conductivity probe
5190-3994
T7111 ATC probe
5190-3998
Agilent 3200C Benchtop Conductivity Meter Package
for Pure Water Analysis
Includes:
Low-conductivity sample measurement of distilled water,
boiler water, and pure water in fields such as energy, pharmacy,
biology, and food safety
G4394A
Agilent 3200C benchtop conductivity meter
G4384A
Agilent 3200EA electrode holder
G4389A
C5113 conductivity probe
5190-3996
T7111 ATC probe
5190-3998
*Default, if not specified otherwise
**For China customers only
(Continued)
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
143
ELECTROCHEMISTRY
All-in-one Packages
Description
Agilent 3200D Benchtop Dissolved Oxygen Meter Package
Includes:
Recommended Use
Part No.
DO measurement of conventional water in applications such as
environmental, monitoring, aquaculture, sewage treatment,
drinking water and research
G4395A
Agilent 3200D benchtop dissolved oxygen meter
G4385A
Agilent 3200EA electrode holder
G4389A
D6111 DO probe, 30 mL bottle of DO filling solution
Agilent 3200I Benchtop Ion Meter Basic Package
Includes:
5190-3997
pH measurement and ion analysis in fields such as scientific
research, process analysis, biochemistry, and pharmacy
(different ion, different electrode)
Agilent 3200I benchtop ion meter
G4386A
Agilent 3200EA electrode holder
G4389A
T7111 ATC probe
5190-3998
pH buffer solutions, 4.01, 7.00, 10.01, NIST traceable, 250 mL, 3/pk
5190-0533*
pH buffer solutions, 4.00, 6.86, 9.18, GB traceable, 250 mL, 3/pk
5190-0534**
P3211 pH combination electrode, includes 30 mL reference solution
5190-3988
Agilent 3200I Benchtop Fluoride Ion Meter Package
Includes:
Measurement of samples such as fluoride water, surface water,
drinking water, and industrial effluent
Agilent 3200I benchtop ion meter
G4397A
G4386A
Agilent 3200EA electrode holder
G4389A
T7111 ATC probe
5190-3998
I9111 fluoride combination ISE, includes 30 mL reference solution
Agilent 3200M Benchtop Multi-Parameter Analyzer Package
Includes:
5190-4002
pH, conductivity, and DO measurement; ion analysis in a wide
range of fields (different ion, different electrode)
G4398A
Agilent 3200M benchtop multi-parameter analyzer
G4387A
Agilent 3200EA electrode holder
G4389A
P3211 pH combination electrode, includes 30 mL reference solution
5190-3988
T7111 ATC probe
5190-3998
pH buffer solutions, 4.01, 7.00, 10.01, NIST traceable, 250 mL, 3/pk
5190-0533*
pH buffer solutions, 4.00, 6.86, 9.18, GB traceable, 250 mL, 3/pk
5190-0534**
D6111 DO probe, 30 mL bottle of DO filling solution
5190-3997
C5111 conductivity probe
5190-3994
*Default, if not specified otherwise
**For China customers only
144
G4396A
ELECTROCHEMISTRY
Electrochemistry Meters*
Description
Part No.
Agilent 3200P benchtop pH meter
G4383A
Agilent 3200C benchtop conductivity meter
G4384A
Agilent 3200D benchtop dissolved oxygen meter
G4385A
Agilent 3200I benchtop ion meter
G4386A
Agilent 3200M benchtop multi-parameter analyzer
G4387A
Accessories
Agilent 3200SA stirrer
G4388A
Agilent 3200EA electrode holder
G4389A
*EC Print software for easy and direct printing and EC Firmware software are available for free download at
www.agilent.com/chem/phmeters
3200SA stirrer, G4388A
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
145
ELECTROCHEMISTRY
Electrodes*
P3211 pH combination electrode,
5190-3988
C5113 Conductivity probe,
5190-3996
Description
Kit Contents
Part No.
P3211 pH combination electrode
Includes 30 mL
reference solution
5190-3988
P3212 pH combination electrode
P3311 pH triode combination electrode
P3212 pH combination electrode,
5190-3989
P3311 pH triode combination
electrode, 5190-3990
D6111 DO probe,
5190-3997
Includes 30 mL
reference solution
P3111 pH electrode
P3213 pH combination electrode
7T111 ATC probe,
5190-3998
5190-3989
5190-3991
Includes 30 mL
reference solution
P3214 pH combination electrode
5190-3993
5190-3994
C5112 conductivity probe
5190-3995
C5113 conductivity probe
5190-3996
D6111 DO probe
P3213 pH combination electrode,
5190-3992
ORP8211 ORP electrode,
5190-3999
R8111 Reference electrode,
5190-4003
5190-3992
C5111 conductivity probe
Includes 30 mL
DO Filling Solution
5190-3997
ORP8211 ORP electrode
Includes 30 mL
reference solution
5190-3999
R8111 reference electrode
Includes 30 mL
reference solution
5190-4003
I9111 fluoride combination ISE
Includes 30 mL
reference solution
5190-4002
I9121 ammonia combination ISE
Includes 30 mL
reference solution
5190-4004
I9131 sodium combination ISE
Includes 30 mL
reference solution
5190-4005
T7111 ATC probe
P3111 pH electrode,
5190-3991
5190-3990
5190-3998
*All electrodes ship with a certificate of conformance and the certificate is also available
online in the literature library
P3214 pH combination electrode,
5190-3993
C5111 Conductivity probe,
5190-3994
C5112 Conductivity probe,
5190-3995
146
I9111 Fluoride combination ISE,
5190-4002
I9121 Ammonia combination ISE,
5190-4004
I9131 Sodium combination ISE,
5190-4005
ELECTROCHEMISTRY
Chemicals*
Description
Amount
Part No.
pH buffer solutions, 4.01, 7.00, 10.01, NIST traceable
3 x 250 mL
5190-0533
pH buffer solutions, 4.00, 6.86, 9.18, GB traceable
3 x 250 mL
5190-0534
pH buffer, 4.01
3 x 250 mL
5190-0535
pH buffer, 10.01
3 x 250 mL
5190-0536
pH buffer, 7.00
3 x 250 mL
5190-0537
pH buffer, 4.00
3 x 250 mL
5190-0538
pH buffer, 6.86
3 x 250 mL
5190-0539
pH buffer, 9.18
3 x 250 mL
5190-0540
Ammonia electrode membrane, 5 pieces
Agilent reference and filling solutions
5190-0543
Ammonia Reference Solution
3 x 30 mL
5190-0544
Reference solution, pH
3 x 250 mL
5190-0545
Sodium ISE Reference Solution
3 x 30 mL
5190-0546
DO filling solution
3 x 30 mL
5190-0547
DO membrane sleeve, 3 pieces
3 x 30 mL
5190-0548
Ammonia electrode membrane, 5190-0543
Accessories
Power adapter, E15WCP1-090100SPA
5185-8389
B620 stirring bar
G4388-27000
BNC-50J short circuit plug
G4383-40000
ATC temperature diagnostic tool
5185-8390
Conductivity diagnostic tool
5185-8391
Power adapter, 5185-8389
*Certificates of analysis ship with this product and are also available online in the literature library.
B620 stirring bar, G4388-27000
BNC-50J short circuit plug, G4383-40000
ATC temperature diagnostic tool, 5185-8390
Conductivity diagnostic tool, 5185-8391
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
147
INTEGRATORS, INTEGRATOR SUPPLIES AND CABLES
Integrators, Integrator Supplies and Cables
Information generation and presentation have never been more important. Agilent understands that data
handling supplies are essential. We provide a convenient way to purchase ink cartridges and integrator
supplies at the same time as other laboratory supplies so you never run out at a crucial moment.
Integrator Cartridges and Printheads
Ink cartridge, 5181-1220
Description
Part No.
Ink cartridge, Agilent 3397A, 3396 Series III, 3396A and B, 3395, 3394
5181-1220
Printhead for 3388A and 5880A
19350-60540
Integrator Paper and Supplies
Paper and Supplies for Agilent 3397A, 3396 Series II, and 3396A/B/95/94
Description
Unit
Part No.
Z-fold paper, sequentially numbered, 8.5 x 11 in, 500 sheets/pk, Inkjet
5/pk
5062-3561
Perforated paper, 8.5 x 11 in rolls, Inkjet
4/pk
5181-1219
Perforated paper, sequentially numbered, 8.5 x 11 in rolls, Inkjet
4/pk
5183-2009
Perforated paper, A4 size rolls, Inkjet
4/pk
Replacement paper roll rod
Replacement paper roll brackets
5181-1255
03394-20500
2/pk
03396-40050
Thermal Paper for Agilent 3390/92/93
Description
Unit
Part No.
Thermal printing paper, blue print, 4.209 in (106.9806 mm) wide x 400 ft
4 rolls/pk
5080-8800
Description
Unit
Part No.
Z-fold paper, black print, 8.5 in wide
8 pk/box
9270-0658
Thermal Paper for Agilent 338X/5830/3370
148
INTEGRATORS, INTEGRATOR SUPPLIES AND CABLES
Cables
3396 Series III Cable Sets
Description
Part No.
Series III Integrator General Purpose cables, signal/remote cable pair includes 35900-60630 and
03396-61031
G2108A
INET interface for integrators, provides INET communications and dual-channel output, includes 1
INET cable
G1553A
Cables to Connect 3397A or 3396/95 Series III Integrator
Cable Type
Instrument
Analog
Remote
Sample
6890 Series GC (non-INET)
G1530-60570 03396-61010
5890 GC (non-INET)
35900-60610
1100/1200 Series LC
35900-60750 03396-61010 03396-60560
General Purpose
35900-60630 03394-60540
Cables to Connect 3394/95A and 3396A/B Integrator
Cable Type
Instrument
Analog
6890 Series GC
G1530-60570
Remote
03396-61020 03396-61010
5890 GC
35900-60610
General Purpose
35900-60630
35900-60900 35900-60920
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
149
INTEGRATORS, INTEGRATOR SUPPLIES AND CABLES
HPIB and GPIB Cables
Description
Part No.
PCI GPIB Card for Win95/98/NT (82350A/B)
G1680-63715
HPIB Cable 2 m (10833B)
10833B-2310
General Purpose Cable GPIO, open end
G1103-61611
HPIB Cable, 8 m (10833G)
10833G-2310
Cable, 6890 to PC 9F/9F RS232
G1530-60600
Crossover Ethertwist Cable, 10 ft
5183-4649
Adapter, extends GPIB connector (10834A)
10834A-2310
Instrument Interface Cables
Description
150
Part No.
Signal cable, general purpose analog output cable assembly, spade lugs/6 pins
G1530-60560
External event control, cable, 8 pins/spade lugs
G1530-60590
Remote start cable for general use with lug
35900-60670
6890 to PC via RS 232-C, 9 female/25 male user card cable
G1530-60610
General purpose binary-coded decimals cable with spade lugs
G1530-60630
Automatic liquid sampler; remote start/stop cable, 2 m 9 male/9 female
G1530-60930
HPIL cable, 5 m
82167-60003
Remote Y Cable, G1512/5890A to 3396C
G1512-60530
Remote Cable to 5890
35900-60700
PRODUCT INDEX
Product Index
CTC Autosampler Supplies
CombiPAL Headspace Syringes ..............................87
CombiPAL and GC PAL Liquid injection
Syringes.........................................................................86
HTS and HTC PAL Liquid Injection
Crimp Top Micro Vials and Caps...........................87
Syringes.......................................................................88
Valve Loops and Needle Seals..............................89
Sample Trays................................................................90
Well Plates ...................................................................90
Crimping and Decapping Tools
Electronic Crimpers and Decappers.......................34
Manual Crimpers and Decappers ...........................35
Electrochemistry
All-in-one Packages .........................................143-144
Chemicals ...................................................................147
Electrode Recommended Uses .....................139-140
Electrode Specifications
Conductivity Probe .................................................142
D6111 Dissolved Oxygen Probe..........................142
Ion Selective ............................................................141
ORP8211 Oxidation Reduction
Potential Electrode.................................................142
R8111 Reference Electrode..................................142
T7111 Automatic Temperature Compensation
Probe .........................................................................142
pH Electrode ............................................................140
Electrodes...................................................................146
Environmental Test Specifications .......................135
Meter Specifications
3200C Conductivity Meter....................................134
3200D Dissolved Oxygen Meter .........................135
3200I Ion Meter ......................................................133
3200M Multi-parameter Analyzer ..............131-132
3200P pH Meter......................................................130
Meters .........................................................................145
Module Specifications.....................................136-137
Fittings
Adapter................................................................118-119
Back Ferrules.............................................................118
Blanking Nut......................................................118-119
Bulkhead Unions...............................................120-121
Caps ............................................................................118
Crosses................................................................119-120
Elbows.................................................................119-120
Fittings Kit...........................................................121-122
Front Ferrules.....................................................117-118
Hose Connector ................................................118-119
Nuts .....................................................................117-118
Nuts, Front and Back Ferrule Sets...............117-118
Plugs ............................................................................118
Reducers .............................................................121-122
Reducing Unions.......................................................121
Tees ..............................................................................119
Unions .................................................................120-121
Zero Dead Volume Unions..............................120-121
Integrators
Cables..................................................................149-150
Cartridges....................................................................148
Paper............................................................................148
Syringes
Flow Meters
ADM Flow Meters....................................................110
Precision Gas Flow Meter..............................111-112
GC Column Accessories
Capillary Column Installation Kit...........................125
Capillary Column Rinse Kit .....................................125
Column Baskets and Hangers...............................126
Fused Silica Tubing Cutters....................................126
GC Installation Kits
Basic Installation ......................................................116
Tubing ..........................................................................116
With Gas Purifiers ....................................................115
With Tools (no gas purifiers) .................................116
Gas Purification
Connection Diagrams...........................................92-94
Gas Clean Filters
Accessories................................................................99
Connecting Units ......................................................98
Fittings.........................................................................99
Replacement Filters .................................................99
Starter Kits..................................................................98
Gas Cylinder Regulators..................................113-114
Gas Leak Detector............................................111-112
Gas Purifier Selection Guide ....................................95
In-Line Gas Traps......................................................101
Renewable Gas Purification System....................100
Universal/External Split Vent Trap .......................109
In-Line Gas Traps
Big Hydrocarbon Traps (BHT Series)...................103
Big Moisture Traps (BMT Series).........................103
Big Oxygen Traps (BOT Series).............................103
Big Universal Traps ..........................................101-102
Combination Traps
Hydrocarbon/Moisture Traps..............................109
Oxygen/Moisture Traps........................................108
Hydrocarbon Traps....................................................106
Indicating Moisture Traps.......................................104
Indicating Oxygen Traps..........................................105
Oxygen Traps .............................................................106
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
Agilent Syringes
7673/7683 On-Column
Autosampler Syringes .............................................68
Blue Line Autosampler Syringes
for 7693A ALS
Advanced Sample Enhancement .......................65
Fitted Plungers ..................................................64-65
PTFE-Tipped Plungers......................................64-65
Gold Standard Autosampler Syringes
Straight Needle, 23 and 26s Gauge...................67
Tapered Needle, 23-26s Gauge...........................66
HP 7670/71/72 Autosampler Syringes...............68
LC Manual Syringes
Fitted Plungers........................................................76
PTFE-Tipped Plungers............................................76
Manual Syringes
Fitted Plunger, Fixed and Removable
Needle .................................................................70-71
LC with Fitted Plungers ........................................76
LC with PTFE-Tipped Plungers............................76
Luer Lok Needles ...................................................75
PTFE-Tipped Plunger and Luer Lok ..............74-75
PTFE-Tipped Plunger, Fixed Needle .............73-74
PTFE-Tipped Plunger, Removable Needle...72-74
Needle Gauge............................................................61
Needle Termination..................................................62
Needle Tip Design ....................................................62
CrossLab Syringes
Autosampler Syringes
for Bruker/Varian Systems ....................................79
Autosampler Syringes
for CTC Analytics Systems.....................................83
Autosampler Syringes for Dionex Systems........84
Autosampler Syringes
for PerkinElmer Systems.........................................80
Autosampler Syringes for Shimadzu Systems.....81
Autosampler Syringes for Thermo Systems ......82
Autosampler Syringes for Waters Systems.......85
Needle Gauge ......................................................77-78
Needle Termination..................................................78
Tools
12-Piece File Set .......................................................129
20x Magnifier.............................................................127
FID Cleaning Kit.........................................................129
Ferrule Tools...............................................................127
General Laboratory Tool Kit....................................123
Hex Keys .....................................................................124
151
PRODUCT INDEX
Injection Port Cleaning Kit......................................128
LC Tool Kits.................................................................123
Microprobes...............................................................127
Mirror...........................................................................128
Pliers and Tweezers .................................................124
Screwdrivers ..............................................................123
Snoop...........................................................................128
Tube Cutters...............................................................124
Wrenches ...................................................................123
Vials and Accessories
Agilent Vials
Crimp Top
2 mL Wide Opening Vials.....................................19
Caps with 11 mm Septa .......................................20
Convenience Packs................................................20
LC ..............................................................................19
General Purpose
Bonded Caps ...........................................................33
Sample Storage Vial Kits ......................................33
Headspace
20 mm Caps and Septa.........................................26
CombiPAL 18 mm Screw Top Caps
with Septa................................................................27
CombiPAL Screw Top Vials..................................27
Convenience Packs................................................26
Crimp Top Vials .......................................................24
High Performance Septa.................................25-26
High Recovery ..........................................................30
MS Analyzed..............................................................14
Micro-V........................................................................30
Microvolume Inserts................................................21
Polypropylene ......................................................22-23
Screw Top
2 mL Standard Opening (8 mm) Vials ...............31
2 mL Wide Opening Vials.....................................15
4 mL (13 mm) Vials................................................32
Caps for 2 mL Vials................................................16
Convenience Packs................................................18
LC ..............................................................................15
Pre-assembled Packs ............................................17
Screw Cap Pack for 7696 Sample Prep
Workbench...............................................................16
Septa for Wide Opening Caps.............................16
Septa Chemical Compatibility..........................10-12
Snap Top
2 mL (11 mm) Vials................................................28
Convenience Packs................................................29
Polyethylene Caps with 11 mm Septa ..............29
Vial Identification Chart...........................................13
CrossLab Vials
Crimp Top
2 mL (11 mm) Vials................................................49
Caps with 11 mm Septa .......................................50
Convenience Packs................................................50
Micro Vials...............................................................51
Cross Reference List..........................................58-59
Headspace
Caps .....................................................................41-42
152
Convenience Packs..........................................42-43
Crimp Top Vials .................................................40-41
High Performance Septa.................................41-42
Screw Top Vials.................................................40-41
Micro-V........................................................................54
Microvolume Inserts................................................55
Polypropylene ............................................................54
Screw Top
10 mL (22 mm) Vials..............................................48
2 mL Standard Opening (8 mm) Vials .........45-46
2 mL Wide Opening (9 mm) Vials ......................43
2 mL Wide Opening Convenience Packs .........45
4 mL (13 mm) Vials................................................47
6 mL (16 mm) Vials................................................48
Caps for 2 mL Vials................................................44
Septa for Wide Opening Caps.............................44
Sealing Mats..............................................................57
Septa Selection .........................................................39
Snap Top
2 mL (11 mm) Vials................................................51
Caps with 11 mm Septa .......................................52
Convenience Packs................................................52
Storage Vial Convenience Packs.................53, 55
Vial Compatibility ......................................................37
Vial Identification Chart...........................................38
Well Plates .................................................................57
Electronic Crimpers and Decappers.......................34
Manual Crimpers and Decappers ...........................35
PART NUMBER INDEX
Part Number Index
0100-0053 ..........................................117
0100-0057 ..........................................117
0100-0058 ..........................................117
0100-0071 ..........................................118
0100-0073 ..........................................122
0100-0088 ..........................................119
0100-0089 ..........................................119
0100-0090 ..........................................119
0100-0091 ..........................................120
0100-0092 ..........................................120
0100-0110 ..........................................121
0100-0111 ..........................................121
0100-0118..................................114, 121
0100-0119..................................114, 121
0100-0121 ..........................................121
0100-0124 ..........................................120
0100-0126 ..........................................120
0100-0128 ..........................................120
0100-0132 ..........................................120
0100-0133 ..........................................120
0100-0161 ..........................................120
0100-0208 ..........................................121
0100-0241 ..........................................121
0100-0420 ..........................................119
0100-0542 ..........................................119
0100-0680 ..........................................119
0100-0782 ..........................................119
0100-0900 ..........................................120
0100-0969 ..........................................119
0100-0985 ..........................................120
0100-0996 ..........................................120
0100-1189 ..........................................121
0100-1315 ..........................................118
0100-1316 ..........................................120
01080-83202......................................119
03394-20500......................................148
03394-60540......................................149
03396-40050......................................148
03396-60560......................................149
03396-61010......................................149
03396-61020......................................149
0460-1266 ..........................................114
07673-40180 ........................................32
10833B-2310 .....................................150
10833G-2310 .....................................150
10834A-2310 .....................................150
1460-1914 ..........................................126
19091-80060......................................126
19199M...............................................116
19199N.........................................98, 115
19251-80680......................................127
19350-60540......................................148
220-1170.............................................110
220-1171-E.........................................110
220-1171-U ........................................110
2869463500 .......................................117
35900-60610......................................149
35900-60630......................................149
35900-60670......................................150
35900-60700......................................150
35900-60750......................................149
35900-60900......................................149
35900-60920......................................149
3700014600 .......................................116
420-1000.............................................126
430-1020.............................................127
430-2000.............................................125
430-3000.............................................125
440-1000.............................................128
450-1000.............................................128
460-1002.............................................128
480-0003.............................................128
5021-7107 ..........................................116
5040-4649.............................................16
5040-4667.............................................35
5040-4668.............................................35
5040-4669.............................................35
5040-4671.............................................35
5040-4681.............................................16
5040-4682.............................................16
5040-4683.............................................16
5042-1386.............................................90
5042-1388.............................................90
5042-1389.............................................90
5042-6454.............................................90
5061-3370......................................20, 29
5062-3561 ..........................................148
5062-3582.............................................20
5064-8211 ..........................................124
5067-0205.............................................18
5067-0218 ..........................................112
5067-0219 ..........................................112
5067-0220 ..........................................112
5067-0223 ..........................................111
5067-0226.............................................24
5067-0227.............................................24
5067-0234.............................................26
5067-0246.............................................32
5067-0247.............................................32
5080-5400 ..........................................128
5080-8750 ..................................115-117
5080-8751 ..........................................117
5080-8752 ..........................................117
5080-8753 ..........................................117
5080-8800 ..........................................148
5180-0805.............................................87
5180-0806.............................................87
5180-0841.............................................87
5180-0842.............................................87
5180-0844.............................................87
5180-4102 ..........................................117
5180-4103..................................117, 122
5180-4104 ..........................................117
5180-4105..................................117, 122
5180-4106 ..........................................117
5180-4108 ..........................................117
5180-4109..................................117, 122
5180-4110 ..........................................117
5180-4111..................................117, 122
5180-4113 ..........................................118
5180-4114 ..........................................118
5180-4115..................................118, 122
5180-4116 ..........................................118
5180-4117..................................118, 122
5180-4120..................................118, 122
5180-4121.................115-116, 118, 122
5180-4124..................................118, 122
5180-4125..................................118, 122
5180-4127..................................120, 122
5180-4128..................................120, 122
5180-4129..................................119, 122
5180-4130 ..........................................121
5180-4131 ..................................121-122
5180-4134 ..........................................122
5180-4135 ..........................................122
5180-4143 ..........................................121
5180-4145 ..........................................121
5180-4148 ..........................................119
5180-4149 ..........................................117
5180-4153 ..........................................128
5180-4160.................115-116, 119, 122
5180-4161 ..........................................122
5180-4162 ..........................................123
5180-4196 ..................................115-116
5181-1210......................................20, 29
5181-1211.............................................20
5181-1212.............................................20
5181-1215.............................................20
5181-1216.............................................20
5181-1217.............................................20
5181-1219 ..........................................148
5181-1220 ..........................................148
5181-1255 ..........................................148
5181-1267.............................................66
5181-1270.............................................21
5181-1273.............................................66
5181-1292 ..........................................117
5181-3319.............................................66
5181-3321.............................................66
5181-3354.............................................66
5181-3356.............................................66
5181-3358.......................................66-67
5181-3360.............................................66
5181-3361.............................................66
5181-3365.............................................66
5181-3375.............................................19
5181-3376.............................................19
5181-3377.............................................21
5181-3400.............................................20
5181-8801.............................................20
5181-8806.............................................67
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
5181-8808.............................................67
5181-8809.............................................67
5181-8810.............................................66
5181-8811.............................................67
5181-8813.............................................67
5181-8836 ..........................................126
5181-8866.............................................68
5181-8872.............................................21
5182-0540.............................................29
5182-0541.............................................29
5182-0542.............................................29
5182-0543.............................................19
5182-0544.............................................28
5182-0545.............................................28
5182-0546.............................................28
5182-0547.............................................29
5182-0548.............................................29
5182-0550.............................................29
5182-0551.............................................32
5182-0552.............................................20
5182-0553.............................................17
5182-0554.............................................17
5182-0555.............................................17
5182-0556.............................................17
5182-0557.............................................17
5182-0558.............................................17
5182-0564.............................................29
5182-0566.............................................29
5182-0567.............................................23
5182-0714.............................................15
5182-0715.............................................15
5182-0716.............................................15
5182-0717.............................................16
5182-0718.............................................16
5182-0719.............................................16
5182-0720.............................................16
5182-0721.............................................16
5182-0722.............................................16
5182-0723.............................................16
5182-0724.............................................16
5182-0725.............................................16
5182-0726.............................................16
5182-0727.............................................16
5182-0728.............................................16
5182-0729.............................................16
5182-0730.............................................16
5182-0731.............................................16
5182-0732.............................................18
5182-0733.............................................18
5182-0734.............................................18
5182-0735.............................................18
5182-0736.............................................18
5182-0737.............................................18
5182-0830.............................................67
5182-0831.............................................68
5182-0832......................................66, 68
5182-0833.............................................68
153
PART NUMBER INDEX
5182-0834.............................................67
5182-0835.............................................66
5182-0836.............................................68
5182-0837.............................................24
5182-0838.............................................24
5182-0839.............................................26
5182-0840.............................................26
5182-0864.............................................17
5182-0865.............................................17
5182-0866.............................................17
5182-0867.............................................18
5182-0868.............................................18
5182-0869.............................................18
5182-0871.............................................20
5182-0875.............................................67
5182-3453 ..........................................116
5182-3454.............................................30
5182-3457.............................................29
5182-3458.............................................29
5182-3459.............................................29
5182-3465..................................116, 123
5182-3466..................................116, 123
5182-9201 ..........................................105
5182-9202 ..........................................105
5182-9211 ..........................................104
5182-9401 ..........................................105
5182-9402 ..........................................105
5182-9411 ..........................................104
5182-9622.............................................68
5182-9626.............................................68
5182-9734.............................................68
5182-9799.............................................68
5183-0314.............................................66
5183-0316.............................................67
5183-0318.............................................67
5183-1941 ..........................................114
5183-2009 ..........................................148
5183-2030.............................................30
5183-2042.............................................66
5183-2058.............................................67
5183-2067.............................................15
5183-2068.............................................15
5183-2069.............................................15
5183-2070.............................................15
5183-2071.............................................15
5183-2072.............................................15
5183-2073.............................................30
5183-2074.............................................16
5183-2075.............................................16
5183-2076.............................................16
5183-2077.............................................16
5183-2078.............................................16
5183-2079.............................................18
5183-2080.............................................18
5183-2081.............................................18
5183-2082.............................................17
5183-2083.............................................17
5183-2085.............................................21
5183-2086.............................................21
5183-2088.............................................31
154
5183-2089.............................................31
5183-2090.............................................31
5183-4301.............................................33
5183-4302.............................................33
5183-4303.............................................33
5183-4304.............................................33
5183-4305.............................................33
5183-4306.............................................33
5183-4307.............................................33
5183-4308.............................................33
5183-4311.............................................33
5183-4312.............................................33
5183-4313.............................................33
5183-4314.............................................33
5183-4321.............................................33
5183-4322.............................................33
5183-4323.............................................33
5183-4324.............................................33
5183-4331.............................................33
5183-4332.............................................33
5183-4333.............................................33
5183-4334.............................................33
5183-4428.............................................31
5183-4429.............................................31
5183-4432.............................................31
5183-4433.............................................31
5183-4436.............................................31
5183-4437.............................................31
5183-4438.............................................31
5183-4442.............................................31
5183-4448.............................................32
5183-4450.............................................32
5183-4459.............................................32
5183-4460.............................................32
5183-4461.............................................32
5183-4464.............................................32
5183-4474.............................................24
5183-4475.............................................24
5183-4477.............................................26
5183-4478.............................................26
5183-4479.............................................26
5183-4480.............................................26
5183-4487.............................................87
5183-4491.............................................19
5183-4492.............................................19
5183-4493.............................................19
5183-4494.............................................19
5183-4495.............................................19
5183-4496.............................................19
5183-4497.............................................30
5183-4498.............................................20
5183-4499.............................................20
5183-4500.............................................20
5183-4504.............................................28
5183-4505.............................................28
5183-4506.............................................28
5183-4507.............................................28
5183-4508.............................................28
5183-4509.............................................28
5183-4510.............................................30
5183-4511.............................................29
5183-4518.............................................31
5183-4620 ..........................................126
5183-4621 ..........................................126
5183-4641 ..........................................114
5183-4642 ..........................................114
5183-4643 ..........................................114
5183-4644 ..........................................114
5183-4645 ..........................................114
5183-4649 ..........................................150
5183-4728.............................................67
5183-4729.............................................67
5183-4730.............................................67
5184-3550.............................................30
5184-3551.............................................30
5184-3552.............................................30
5184-3554.............................................30
5184-3555.............................................30
5184-3556.............................................30
5185-5820.............................................16
5185-5823.............................................16
5185-5824.............................................16
5185-5829.............................................16
5185-5838.............................................16
5185-5861.............................................16
5185-5862.............................................16
5185-5863.............................................16
5185-5864.............................................16
5185-5865.............................................16
5185-8389 ..........................................147
5185-8390 ..........................................147
5185-8391 ..........................................147
5188-2753.............................................27
5188-2758.............................................15
5188-2759.............................................27
5188-2788.............................................23
5188-5246.............................................67
5188-5247.............................................67
5188-5369.............................................15
5188-5370.............................................67
5188-5371.............................................67
5188-5386.............................................20
5188-5390.............................................23
5188-5392.............................................27
5188-5395.............................................88
5188-6457.............................................89
5188-6458.............................................89
5188-6460.............................................89
5188-6461.............................................89
5188-6462.............................................89
5188-6463.............................................89
5188-6464.............................................89
5188-6465.............................................89
5188-6466.............................................89
5188-6467.............................................89
5188-6468.............................................89
5188-6469.............................................89
5188-6470.............................................89
5188-6471.............................................87
5188-6476.............................................89
5188-6477.............................................89
5188-6478.............................................89
5188-6479.............................................90
5188-6485.............................................88
5188-6486.............................................89
5188-6487.............................................89
5188-6488.............................................89
5188-6489.............................................89
5188-6490.............................................89
5188-6491.............................................89
5188-6492.............................................89
5188-6535.............................................15
5188-6536.............................................15
5188-6537.............................................27
5188-6538.............................................27
5188-6572.............................................19
5188-6593.............................................28
5188-6594.............................................28
5188-6596.............................................86
5190-0464.............................................70
5190-0533 .........................143-144, 147
5190-0534 .........................143-144, 147
5190-0535 ..........................................147
5190-0536 ..........................................147
5190-0537 ..........................................147
5190-0538 ..........................................147
5190-0539 ..........................................147
5190-0540 ..........................................147
5190-0543 ..........................................147
5190-0544 ..........................................147
5190-0545 ..........................................147
5190-0546 ..........................................147
5190-0547 ..........................................147
5190-0548 ..........................................147
5190-1414 ..........................................100
5190-1442 ..........................................124
5190-1457.............................................75
5190-1460.............................................70
5190-1461.............................................70
5190-1462.............................................70
5190-1463.............................................70
5190-1464.............................................70
5190-1465.............................................70
5190-1466.............................................70
5190-1467.............................................70
5190-1468.............................................70
5190-1469.............................................70
5190-1470.............................................70
5190-1471.............................................70
5190-1472.............................................70
5190-1473.............................................70
5190-1474.............................................70
5190-1475.............................................70
5190-1476.............................................70
5190-1477.............................................70
5190-1478.............................................70
5190-1479.............................................70
5190-1480.............................................76
5190-1481.............................................70
5190-1482.............................................70
PART NUMBER INDEX
5190-1483.............................................71
5190-1484.............................................76
5190-1485.............................................76
5190-1486.............................................76
5190-1487.............................................71
5190-1488.............................................71
5190-1489.............................................71
5190-1490.............................................73
5190-1491.............................................72
5190-1492.............................................76
5190-1493.............................................71
5190-1494.............................................76
5190-1495.............................................71
5190-1496.......................................71-72
5190-1497.............................................73
5190-1498.............................................72
5190-1499.............................................76
5190-1500.............................................71
5190-1501.............................................76
5190-1502.............................................71
5190-1503.............................................73
5190-1504.............................................72
5190-1505.............................................76
5190-1506.............................................74
5190-1507.............................................71
5190-1508.............................................76
5190-1509.............................................71
5190-1510.............................................73
5190-1511.............................................72
5190-1512.............................................76
5190-1513.............................................74
5190-1514.............................................71
5190-1515.............................................76
5190-1516.............................................71
5190-1517.............................................73
5190-1518.............................................72
5190-1519.............................................74
5190-1520.............................................76
5190-1521.............................................71
5190-1522.............................................76
5190-1523.............................................73
5190-1524.............................................71
5190-1525.............................................72
5190-1526.............................................76
5190-1527.............................................74
5190-1528.............................................74
5190-1529.............................................73
5190-1530.............................................75
5190-1531.............................................75
5190-1532.............................................74
5190-1533.............................................73
5190-1534.............................................75
5190-1535.............................................75
5190-1536.............................................74
5190-1537.............................................73
5190-1538.............................................73
5190-1539.............................................75
5190-1540.............................................75
5190-1541.............................................74
5190-1542.............................................73
5190-1543.............................................75
5190-1544.............................................75
5190-1545.............................................75
5190-1546.............................................75
5190-1547.............................................75
5190-1548.............................................75
5190-1549.............................................75
5190-1550.............................................75
5190-1558......................................73, 76
5190-1559.............................................72
5190-1560 ................................72-73, 76
5190-1561 ................................72-74, 76
5190-1562 ................................72-74, 76
5190-1563.......................................72-74
5190-1564 ................................72-74, 76
5190-1565.......................................73-75
5190-1571.............................................76
5190-1572.......................................73-75
5190-1573.......................................73-75
5190-1574.......................................73-75
5190-1575.............................................75
5190-1576.............................................75
5190-1577.............................................75
5190-1581.............................................73
5190-1599.............................................16
5190-2238.............................................24
5190-2239.............................................24
5190-2240.............................................29
5190-2241.............................................20
5190-2242.............................................23
5190-2243.............................................23
5190-2257.............................................26
5190-2258.............................................26
5190-2277.............................................14
5190-2278.............................................14
5190-2279.............................................14
5190-2280.............................................14
5190-2281.............................................14
5190-2282.............................................14
5190-2283.............................................14
5190-2285.............................................24
5190-2286.............................................24
5190-2287.............................................24
5190-2288.............................................24
5190-3155.............................................23
5190-3188.............................................34
5190-3189.............................................34
5190-3190.............................................34
5190-3191.............................................34
5190-3192.............................................34
5190-3193.............................................67
5190-3984.............................................86
5190-3985.............................................86
5190-3988 .........................143-144, 146
5190-3989 ..........................................146
5190-3990..................................143, 146
5190-3991 ..........................................146
5190-3992 ..........................................146
5190-3993 ..........................................146
5190-3994 .........................143-144, 146
5190-3995 ..........................................146
5190-3996..................................143, 146
5190-3997..................................144, 146
5190-3998 .........................143-144, 146
5190-3999 ..........................................146
5190-4002..................................144, 146
5190-4003 ..........................................146
5190-4004 ..........................................146
5190-4005 ..........................................146
5190-4048.............................................87
5190-4061.............................................34
5190-4062.............................................34
5190-4063.............................................34
5190-4064.............................................34
5190-4065.............................................34
5190-4066.............................................34
5190-4067.............................................34
5965-0027 ..........................................124
5965-0028 ..........................................124
707-0027.............................................128
7157-0210 ..........................................116
8001-0001.............................................81
8001-0002.............................................81
8001-0003.............................................81
8001-0004.............................................81
8001-0005.............................................81
8001-0006.............................................81
8001-0007.............................................81
8001-0401.............................................81
8001-0402.............................................81
8001-0404.............................................81
8002-0001.............................................82
8002-0002.............................................82
8002-0003.......................................82-83
8002-0004.......................................82-83
8002-0005.......................................82-83
8002-0401.............................................84
8002-0402.............................................84
8002-0403.............................................84
8002-0404.............................................84
8002-0405.............................................84
8002-0406.............................................84
8002-0407.............................................84
8002-0408.............................................84
8002-0412.............................................84
8002-0413.............................................84
8002-0414.............................................84
8002-0415.............................................84
8003-0001.............................................80
8003-0002.............................................80
8003-0003.............................................80
8003-0004.............................................80
8003-0005.............................................80
8003-0006.............................................80
8003-0007.............................................80
8003-0008.............................................80
8004-0001.............................................79
8004-0002.............................................79
8004-0003.............................................79
8004-0004.............................................79
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
8004-0005.............................................79
8004-0006.............................................79
8004-0007.............................................79
8005-0414.............................................85
8005-0416.............................................85
8005-0417.............................................85
8005-0418.............................................85
8005-0419.............................................85
8005-0420.............................................85
8010-0001.............................................49
8010-0002.............................................49
8010-0003.............................................49
8010-0004.............................................54
8010-0005.............................................54
8010-0006.............................................49
8010-0007.............................................49
8010-0008.............................................43
8010-0009.............................................43
8010-0010.............................................45
8010-0011.............................................45
8010-0012.............................................45
8010-0013.............................................45
8010-0014.............................................43
8010-0015.............................................43
8010-0016.............................................43
8010-0017.............................................43
8010-0018.............................................54
8010-0019.............................................54
8010-0020.............................................47
8010-0021.............................................47
8010-0022.............................................48
8010-0023.............................................51
8010-0024.............................................51
8010-0025.............................................51
8010-0026.............................................51
8010-0027.............................................54
8010-0028.............................................54
8010-0029.............................................40
8010-0030.............................................40
8010-0031.............................................40
8010-0032.............................................40
8010-0033.............................................40
8010-0034.............................................40
8010-0035.............................................40
8010-0036.............................................40
8010-0038.............................................40
8010-0040.............................................40
8010-0042.............................................40
8010-0044.............................................40
8010-0045.............................................50
8010-0046.............................................50
8010-0047.............................................50
8010-0048.............................................50
8010-0049.............................................50
8010-0050.............................................50
8010-0051.............................................50
8010-0052.............................................50
8010-0053.............................................50
8010-0054.............................................46
8010-0055.............................................46
155
PART NUMBER INDEX
8010-0056.............................................46
8010-0057.............................................46
8010-0058.............................................46
8010-0059.............................................46
8010-0060.............................................46
8010-0061.............................................46
8010-0062.............................................46
8010-0063.............................................46
8010-0064.............................................46
8010-0065.............................................46
8010-0066.............................................46
8010-0067.............................................46
8010-0068.............................................46
8010-0069.............................................46
8010-0070.............................................46
8010-0071.............................................46
8010-0072.............................................46
8010-0073.............................................46
8010-0074.............................................44
8010-0075.............................................44
8010-0076.............................................44
8010-0077.............................................44
8010-0078.............................................44
8010-0079.............................................44
8010-0080.............................................44
8010-0081.............................................44
8010-0082.............................................44
8010-0083.............................................44
8010-0084.............................................44
8010-0085.............................................44
8010-0086.............................................44
8010-0087.............................................44
8010-0088.............................................44
8010-0089.............................................44
8010-0091.............................................44
8010-0092.............................................44
8010-0093.............................................44
8010-0094.............................................44
8010-0095.............................................47
8010-0096.............................................47
8010-0098.............................................47
8010-0099.............................................47
8010-0100.............................................48
8010-0101.............................................48
8010-0102.............................................48
8010-0103.............................................52
8010-0104.............................................52
8010-0105.............................................52
8010-0106.............................................52
8010-0107.............................................52
8010-0108.............................................52
8010-0109.............................................52
8010-0110.............................................52
8010-0111.............................................52
8010-0112.............................................52
8010-0113.............................................52
8010-0115.............................................52
8010-0116.............................................42
8010-0117.............................................42
8010-0119.............................................42
156
8010-0120.............................................42
8010-0121.............................................42
8010-0122.............................................42
8010-0124.............................................55
8010-0125.............................................55
8010-0126.............................................55
8010-0131.............................................55
8010-0132.............................................55
8010-0136.............................................55
8010-0139.............................................42
8010-0140.............................................42
8010-0141.............................................46
8010-0142.............................................46
8010-0143.............................................42
8010-0144.............................................42
8010-0151.............................................41
8010-0152.............................................41
8010-0153.............................................51
8010-0154.............................................51
8010-0155.............................................51
8010-0158.............................................54
8010-0159.............................................54
8010-0160.............................................54
8010-0161.............................................54
8010-0162.............................................54
8010-0165.............................................42
8010-0166.............................................46
8010-0170.............................................49
8010-0172.............................................49
8010-0175.............................................43
8010-0176.............................................43
8010-0177.............................................51
8010-0178.............................................51
8010-0179.............................................40
8010-0180.............................................40
8010-0181.............................................50
8010-0182.............................................50
8010-0183.............................................50
8010-0186.............................................44
8010-0187.............................................44
8010-0188.............................................44
8010-0189.............................................52
8010-0190.............................................52
8010-0191.............................................42
8010-0192.............................................42
8010-0193.............................................54
8010-0194.............................................54
8010-0195.............................................50
8010-0196.............................................50
8010-0198.............................................45
8010-0199.............................................45
8010-0200.............................................52
8010-0351 ................................79, 82-83
8010-0352.......................................82-83
8010-0353.......................................82-83
8010-0354.......................................82-83
8010-0355.......................................82-83
8010-0356.............................................83
8010-0357.............................................83
8010-0358.............................................83
8010-0359.............................................83
8010-0360.............................................83
8010-0361.............................................83
8010-0362.............................................83
8010-0363.............................................83
8010-0364.............................................83
8010-0365.............................................83
8010-0366.............................................83
8010-0367.......................................82-83
8010-0368.............................................82
8010-0411.............................................52
8010-0412.............................................42
8010-0413.............................................42
8010-0414.............................................45
8010-0415.............................................45
8010-0416.............................................53
8010-0417.............................................42
8010-0418.............................................42
8010-0420.............................................42
8010-0422.............................................53
8010-0423.............................................53
8010-0424.............................................42
8010-0425.............................................45
8010-0426.............................................45
8010-0427.............................................45
8010-0428.............................................42
8010-0429.............................................42
8010-0430.............................................53
8010-0441.............................................85
8010-0442.............................................85
8010-0443.............................................85
8010-0444.............................................85
8010-0445.............................................85
8010-0446.............................................85
8010-0448.............................................85
8010-0455.............................................85
8010-0460.............................................85
8010-0467.............................................85
8010-0468.............................................85
8010-0532.............................................57
8010-0533.............................................57
8010-0534.............................................57
8010-0535.............................................57
8010-0536.............................................57
8010-0537.............................................57
8010-0538.............................................57
8010-0539.............................................57
8010-0540.............................................57
8010-0541.............................................57
8010-0542.............................................45
8010-0543.............................................45
8010-0545.............................................45
8010-0546.............................................45
8010-0547.............................................45
8010-0548.............................................45
8010-0553.............................................47
8010-0554.............................................47
8010-0555.............................................47
8010-0556.............................................47
8010-0557.............................................47
8010-0558.............................................55
8010-0559.............................................47
8010-0560.............................................47
8010-0561.............................................47
8010-0562.............................................47
8010-0563.............................................48
8010-0564.............................................48
8010-0565.............................................48
8010-0566.............................................50
8010-0567.............................................50
8010-0568.............................................50
8010-0569.............................................50
8010-0574.............................................55
8010-0575.............................................55
8010-0577.............................................57
8010-0578.............................................57
8010-0582.............................................50
82167-60003......................................150
8710-0004 ..........................................124
8710-0007 ..........................................124
8710-0018 ..........................................124
8710-0510..................................116, 123
8710-0641 ..........................................124
8710-0803..................................116, 123
8710-0806..................................116, 123
8710-0899 ..........................................123
8710-0900 ..........................................123
8710-0972..................................116, 123
8710-1217 ..........................................116
8710-1534 ..........................................123
8710-1707 ..........................................124
8710-1708 ..........................................124
8710-1709 .........................115-116, 124
8710-1712 ..........................................123
8710-1841 ..........................................123
8710-1924 ..........................................123
8710-1930 ..........................................124
8710-1931 ..........................................124
8710-2392 ..........................................124
8710-2393 ..........................................124
8710-2394 ..........................................124
8710-2411 ..........................................124
8710-2412 ..........................................124
8720-0010 ..........................................123
8720-0025 ..........................................123
907-0056.............................................110
9270-0658 ..........................................148
9300-0311 .........................115-116, 128
9301-0713.............................................67
9301-0714.............................................67
9301-0718.............................................26
9301-0719.............................................26
9301-0721.............................................26
9301-0723.............................................32
9301-0725.............................................67
9301-0891.............................................67
9301-0892.............................................67
9301-0976.............................................26
9301-0977.............................................23
9301-0978.............................................23
PART NUMBER INDEX
9301-0985 ..........................................129
9301-1031.............................................32
9301-1130.............................................31
9301-1377.............................................15
9301-1378.............................................15
9301-1379.............................................15
9301-1387.............................................21
9301-1388.............................................19
9301-1419.............................................19
9301-1425.............................................19
AL30509 .............................................116
AL45734 .............................................116
BHT-2 ..................................................103
BHT-4 ..................................................103
BMT-2 .................................................103
BMT-4 .................................................103
BOT-2 ..................................................103
CP17969................................................99
CP17970................................................99
CP17971................................................99
CP17971P.............................................99
CP17972................................................99
CP17973................................................99
CP17976................................................98
CP17977................................................98
CP17978................................................98
CP17982................................................98
CP17983................................................98
CP17984................................................98
CP17985................................................98
CP4013................................................116
CP4024................................................116
CP4025................................................116
CP4026................................................116
CP4030................................................116
CP4032................................................116
CP736520 .............................................98
CP736530 ....................................98, 115
CP738406 .............................................98
CP738407 .............................................98
CP738408 .............................................98
CP741648 ...........................................121
CP7978..................................................99
CP7980..................................................98
CP7980P4.............................................98
CP7980P6.............................................98
CP7981..................................................99
CP7983..................................................99
CP7986..................................................99
CP7986SS.............................................99
CP7986SS6...........................................99
CP7987..................................................99
CP7988..................................................98
CP7988P3.............................................98
CP7988P8.............................................98
CP7989..................................................98
CP7995..................................................98
CP82117................................................99
CP82117SS...........................................99
CP82117SS3 ........................................99
G1099-20030 .....................................127
G1103-61611 .....................................150
G1512-60530 .....................................150
G1530-60560 .....................................150
G1530-60570 .....................................149
G1530-60590 .....................................150
G1530-60600 .....................................150
G1530-60610 .....................................150
G1530-60630 .....................................150
G1530-60930 .....................................150
G1530-61580 .....................................126
G1553A...............................................149
G1680-63715 .....................................150
G1999-80410 .....................................109
G2108A...............................................149
G2630-80800 .....................................126
G3388B...............................................112
G3440-60003 .....................................100
G3440-60004 .....................................100
G3440-69003 .....................................100
G3440-80007 .....................................100
G4200-80101..................................87-88
G4200-80102.................................86, 88
G4200-80103........................................88
G4200-80104.................................86, 88
G4200-80105.................................86, 88
G4200-80106.................................86, 88
G4200-80107..................................87-88
G4200-80108..................................87-88
G4200-80111........................................88
G4200-80112........................................88
G4200-80113........................................88
G4200-80114........................................88
G4200-80115........................................88
G4200-80116........................................88
G4200-80117........................................88
G4200-80118........................................88
G4200-80119........................................88
G4203-68708 .....................................123
G4296-68715 .....................................123
G4383-40000 .....................................147
G4383A......................................143, 145
G4384A......................................143, 145
G4385A.......................................144-145
G4386A.......................................144-145
G4387A.......................................144-145
G4388-27000 .....................................147
G4388A...............................................145
G4389A.......................................143-145
G4391A...............................................143
G4392A...............................................143
G4393A...............................................143
G4394A...............................................143
G4395A...............................................144
G4396A...............................................144
G4397A...............................................144
G4398A...............................................144
G4513-60560........................................65
G4513-60561........................................65
G4513-80200........................................64
G4513-80201........................................64
G4513-80202........................................64
G4513-80203........................................65
G4513-80204........................................64
G4513-80205........................................64
G4513-80206........................................64
G4513-80208........................................65
G4513-80209........................................64
G4513-80210........................................65
G4513-80211........................................64
G4513-80212........................................64
G4513-80213........................................64
G4513-80215........................................64
G4513-80216........................................64
G4513-80218........................................64
G4513-80219........................................65
G4513-80220........................................65
G4513-80221........................................65
G4513-80222........................................65
G4513-80223........................................65
G4513-80224........................................64
G4513-80225..................................64-65
G4513-80226........................................64
G4513-80227........................................65
G4513-80228........................................65
G4513-80229........................................64
G4513-80233........................................65
G4513-80234........................................64
G4513-80235........................................64
G4513-80236..................................64-65
G4513-80239........................................64
G4513-80240........................................64
G4513-80241........................................65
G4513-80242........................................64
G4513-80243........................................64
G4513-80244........................................64
G6500-80100........................................90
G6500-80101........................................90
G6500-80102........................................88
G6500-80103........................................88
G6500-80104........................................88
G6500-80105........................................88
G6500-80106........................................88
G6500-80107........................................87
G6500-80109........................................87
G6500-80111........................................87
G6500-80113........................................86
G6500-80114........................................86
G6500-80115........................................86
G6500-80116........................................86
G6500-80117........................................86
G6500-80118........................................86
G6500-80119........................................86
G6500-80120........................................86
G6500-80121........................................90
G6500-80122........................................90
HMT200-2..........................................109
HMT200-4..........................................109
HT200-2..............................................106
HT200-4..............................................106
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
HT3-2 ..................................................106
HT3-4 ..................................................106
MC-1 ..................................106, 108-109
OT1-2...................................................106
OT1-4...................................................106
OT3-2...................................................108
OT3-4...................................................108
RDT-1020...................................109, 115
RDT-1023............................................109
RFT-2500.............................................127
RFT-5300.............................................127
RMP-5005 ..........................................127
RMSH-2..............................................102
RMSH-4..............................................102
RMSHY-2 ............................................102
RMSHY-4 ............................................102
RMSN-2..............................................102
RMSN-4..............................................102
RSF-1200 ............................................129
SWB1021...........................................117
SWSS20074.......................................121
SWSS4031.........................................117
SWSS4041.........................................118
UMC-5-2.....................................102-103
157
ORDERING INFORMATION
Ordering Information
Easy Ordering Terms and Conditions
Discounts and Delivery
Agilent Technologies specializes in fast delivery. In the US, if you call before 2 PM EST, we will ship your
order that day. You may also request overnight express delivery before 6 PM EST and you will have your
order the next day. Volume discounts on a variety of individual products are offered when the entire quantity
is shipped to one address at one time.
A shipping and handling fee will be added to your order unless the purchase is over $2000 US for orders
place online or over $4000 for orders place via phone. Special shipping (i.e., overnight in the US) is
available in most regions at an additional cost.
Agilent is required to collect all state and local sales taxes unless the buyer's tax-exempt certificate is on file
with Agilent Technologies. Please be prepared to provide a copy if it is not on file, when placing your order.
Please check with your Agilent Customer Service Representative, local Authorized Distributor, or the Agilent
website for current prices, special offers, promotions and discounts when placing your order.
Satisfaction Guaranteed
If you are not satisfied with your Agilent product within the first 60 days, you may return your purchase in its
original condition for a full refund or credit. A return policy statement is included in every Agilent shipment
and posted under Product Information on the website. In the US and Canada, please call for a Return
Authorization form and return instructions at 1-800-227-9770. If your Agilent product was purchased from
a distributor, please contact the distributor.
Shipping Damages
If items are damages in transit, please follow the instructions below:
• If a shipment is visibly damaged upon arrival, do not accept it until the person making the delivery has
endorsed the bill of lading with statement for the extent of the damage.
• If any damage is found after unpacking, retain all cartons and inner packaging and immediately
request an inspection from the carrier.
• Notify the Agilent Customer Contact Center at 1-800-227-9770 about the damaged shipment so that
we can make the appropriate sales adjustment and/or provide you with return instructions (Sales order
number, product number and quantity damaged will be needed).
158
ORDERING INFORMATION
Easy Ways To Order
• Phone: 1-800-227-9770 (option 1, 1) in the US and Canada – Mon-Fri, 8AM to 8PM EST
• Fax: 1-302-633-8901 in the US
• Email: [email protected] in the US and Canada
• Online: www.agilent.com/chem in the US and Canada
Payment Options
• In the US, Visa, MasterCard, Discover and American Express are accepted with a minimum order of
$20 (not applicable in all countries).
• Email [email protected] to make an electronic payment using the ACH/EFT (Automated Clearing
House/Electronic Funds Transfer) method.
• Establish a charge account through your Agilent Customer Service Representative or Your Local Agilent
sales office. An account number will be assigned to you for charging your purchases. Payment terms
are net 30 days from the invoice date. All orders are subject to credit approval.
We will be happy to supply a price quote via, phone, email or fax if you need it in writing.
Warranties
All Agilent Technologies products in this catalog are designed and manufactured to stringent standards
under the Agilent quality system registered to ISO 9001. At Agilent, we back every product with a 90-day
warranty and a money-back guarantee. If Agilent receives notice of defects during the warranty period.
Agilent shall, at its option, either repair or replace products which prove to be defective. If Agilent is unable,
within a reasonable time, to repair or replace any product to a condition as warranted, the buyer shall be
entitled to a refund of the purchase price upon return of the product to Agilent. The warranty period for
each product begins on the day of shipment.
This warranty shall not apply to any defect, failure, or damage caused by improper use or improper or
inadequate maintenance or care. This warranty is exclusive and no other warranty, whether written or oral,
is expressed or implied. Agilent specifically disclaims the implied warranties of merchantability and fitness
for particular purposes. The remedies provided herein are the buyer's sole and exclusive remedies. In no
event shall Agilent be liable for direct, indirect, special, incidental, or consequential damages (including loss
of profits) whether based on contract, tort, or any other legal theory.
WWW.AGILENT.COM/CHEM/GENERALSUPPLIES
159
ORDERING INFORMATION
Agilent Technologies Order Form
Agilent Technologies
Outside the U.S. and Canada, please contact your local Agilent office or Authorized Distributor when ordering.
Order Date
Purchase Order or Credit Card Number & Expiration
Name:
Title:
Phone:
Company:
Taxable
Y or N?
Yes
No
If No, please provide Certificate #
Fax:
Email:
Shipping Address
Billing Address
Company:
Street:
Room/Bldg/Dept:
City:
State/Province/Country:
Zip/Postal Code:
Deliver to:
Part Number
Special Instructions:
Description
Quantity
Price
Total Cost
Subtotal:
Tax:
Total:
For Assistance: Please call the Agilent Technologies Customer Contact Center at 1-800-227-9770 (U.S. and Canada)
Email Node:
[email protected]
Fax Number:
302-633-8901 U.S. and Canada
Note: 1. All pricing, tax, discount, and availability information is subject to verification by Agilent Technologies.
2. Shipping and handling is free for orders over $2000 US.
160
GENERAL CHROMATOGRAPHY
SUPPLIES
NEW FORMAT. SAME ESSENTIAL RESOURCE.
The Essential Chromatography and Spectroscopy Catalog is now available
in a boxed set to help you easily find the products and information you need.
Each catalog is your essential resource for:
• Product photos and ordering information
• Troubleshooting tips
• Selection guides and applications
• Maintenance schedules
• Compatibility charts
Minimize contamination and ensure accurate,
reproducible results
As the world’s premier measurement company, Agilent is uniquely positioned to offer you the widest
selection of parts and supplies. All are engineered or selected by our experienced design teams,
manufactured to our demanding specifications, and tested under the strictest conditions.
Your boxed set includes comprehensive information for Agilent's
entire portfolio of Chromatography and Spectroscopy columns
and supplies in the following catalogs:
General Chromatography Supplies – Minimize contamination and ensure accurate,
reproducible results with our selection of vials, syringes, gas purification systems, fittings
and tools, and electrochemistry meters.
• Vials, caps and septa are designed to work flawlessly with your autosampler’s gripping and
injection mechanisms – eliminating breakage and leaks that can cause unnecessary downtime,
expensive repairs, and sample loss. We have also expanded our portfolio to include MS analyzed kits,
Agilent Certified Vials, and NEW Agilent CrossLab Vials for non-Agilent autosamplers.
Sample Preparation Products for Chromatography – Reliably extract and concentrate
samples from complex matrices with Bond Elut SPE cartridges, pre-packaged QuEChERS kits,
sample filtration products, dried matrix spotting cards and pre-measured TOXI-TUBES.
• Manual and autosampler syringes boost performance along every step of your sampling process.
Designed for accuracy, reliability and ease of use, Agilent syringes ensure exact measurement,
transport, and delivery of liquids necessary for sample preparation and injection.
• Renewable gas purification system extends column life and reduces baseline noise by removing
GC and GC/MS – Achieve excellent, reproducible performance for difficult samples with
ultra inert solutions for GC, premium inlet supplies, Agilent J&W GC columns and standards, and more.
oxygen, water, and hydrocarbons from carrier gasses. One renewable cartridge can support up to
four GC systems, while delivering the same filtration capacity as multiple competitive cartridges.
• Gas Clean filter system prevents dirty gas from jeopardizing your analysis. Oxygen, hydrocarbons,
and moisture can decrease GC sensitivity; they can also activate glass wool in liners and accelerate
septa degradation, causing high background noise and ghost peaks. Inserting a gas clean filter
immediately before your GC inlet greatly reduces the level of impurities, improving trace analysis.
• Fittings and tools make life in the lab easier by keeping your instruments running in top form.
• Electrochemistry meters are designed by chromatographers for chromatographers to give you
rugged simplicity and fast, reliable data. Features such as user-friendly controls, waterproof
connectors, and multi-parameter measurement capabilities make Agilent pH, DO, ISE, conductivity
and multi-parameter meters your first choice for a broad range of applications.
LC and LC/MS, including CE and CE/MS – Maximize system performance and produce
quality results time after time with LC capillaries, lamps, and the entire family of ZORBAX LC columns
for small molecules, biomolecules and GPC/SEC.
Spectroscopy – Satisfy your growing demand to screen large numbers of samples, faster, with supplies
and standards for Atomic Absorption, ICP-OES, ICP-MS, MP-AES and Molecular Spectroscopy.
For more information and to request additional catalogs,
please visit www.agilent.com/chem/catalog
Special Offers from Agilent
You don't have to look far to find valuable offers that feature high-performance
columns and supplies, accessories, and more.
Just go to www.agilent.com/chem/specialoffers to find out about our latest offers.
And be sure to check back often, because we'll update this page throughout the year!
For more details about these offers, contact your local Agilent office or Authorized Agilent Distributor.
Buy online:
www.agilent.com/chem/store
Contact us:
www.agilent.com/chem/contactus
This information is subject to change without notice.
© Agilent Technologies, Inc. 2012
Printed in Canada October 31, 2012
5991-1056EN
Scan the QR code
with your smartphone
for more information
THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG
For more information
GENERAL
CHROMATOGRAPHY
GENERAL CHROMATOGRAPHY
Your Essential Resource for Supplies
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement