MOMENTS
BATH/SHOWER TRIM KIT
Installation
Instructions
T506.50X
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1
M968951 Rev. 1.4
Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Pipe Wrench Plumbers' Putty or Caulking
Phillips Screwdriver
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note roughing-in dimensions.
3/4"" TO 2-3/8"
FINISHED WALL
1/2" NPT SHR. 1/2" NOM.
COPPER SWEAT
SWEAT
INLETS
INLETS
4-1/16"
5-5/8" REF.
2-3/8"
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
TUB 1/2" NOM.
COPPER SWEAT
8-1/8" REF.
"SEE ILLUSTRATION "
74" FOR
HEAD CLEARANCE
8-3/8" SHR
SWEAT
INLETS (STOPS)
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
5-7/8"
TUB
18"
OPTIONAL
6-1/2"
3-3/8"
INLETS 1/2" NPT
Channel Locks
INLETS
1/2" NOM.
COPPER
SWEAT
2"
4-1/16"
4-1/16"
INLETS
1/2" NOM.
COPPER
SWEAT
OUTLETS
1/2" NPT
5-7/8"
1/2" NPT
1-1/2" REF.
3-3/8"
TOP OF
TUB RIM
BOTTOM OF
TUB
4"
OUTLETS
1/2" NPT
THREADED INLETS
3-3/8"
INLETS
1/2" NPT
THREADED INLETS (STOPS)
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
1
INSTALL VALVE TRIM
Figure 1. Remove plaster guard from valve. Push CAP (1) over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1) and attach with LONG SCREWS (4). Mount ESCUTCHEON
SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT
SCREWS (6).
Figure 3. Align PINS (7) on back side of ESCUTCHEON (8) with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5) and press ESCUTCHEON (8) flush against finished wall.
PLSTER
GUARD
Figure 1.
9
5
1
3
5
2
1
7
8
4
Figure 2.
Figure 3.
6
2
INSTALL TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER
HEAD and TUB SPOUT when installing.
Remove pipe cap and plug from shower and tub rough piping.
Install SPOUT ESCUTCHEON (1) onto TUB SPOUT (2).
Apply sealant or Teflon tape to threads of tub filler nipple. Thread TUB SPOUT (2) onto tub nipple.
CAUTION: Protect finish on TUB SPOUT when installing.
Install SHOWER ESCUTCHEON (3) onto SHOWER
ARM (4). Apply sealant or Teflon tape to threads on both ends of SHOWER ARM (4) and thread longer leg of SHOWER ARM (4) into shower elbow.
Thread SHOWER HEAD (5) onto SHOWER ARM (4).
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
5
3
4
2
SHR.
ELBOW
PIPE
PLUG
TUB FILLER
NIPPLE
.
1-1/2" REF
2
1
M968951 Rev. 1.4
3
ADJUST HOT LIMIT STOP
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
4
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
HANDLE INSTALLATION
INSTALL HANDLE ADAPTER
Push HANDLE ADAPTER (1) onto VALVE STEM (2).
Tighten set screw (3) with 2.5mm hex wrench supplied.
2
1
"RED RING"- HOT
LIMIT SAFETY STOP
"A"
0 1 2 3 4 5
6
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
TEMPERATURE
SETTING
NUMBERS
"B"
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
4a
INSTALL ADAPTER SCREW
With a flat blade screwdriver thread ADAPTER SCREW (4) into
HANDLE STEM ADAPTER (1) and tighten.
1
1
3
2.5MM HEX
WRENCH
4b
INSTALL ADPATER
With a flat blade screwdriver thread ADAPTER (5) onto SET SCREW (4) and tighten.
4
4c
INSTALL HANDLE
Align HANDLE (6) and install onto
HANDLE ADAPTER ASSEMBLY (7).
Tighten set screw (8) with 2.5mm
hex wrench supplied to secure HANDLE.
Push PLUG BUTTON (9) into set screw access hole in HANDLE (6).
6
8
7
9
2.5MM HEX
WRENCH
5
4
5
SERVICE
If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
Remove HANDLE (1), CAP (2) and CARTRIDGE (4).
Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
5
4
CARTRIDGE
INLETS
3
2
1
M968951 Rev. 1.4