American Standard T506.507.002 Moments FloWise Bath/Shower Trim Kits Installation Instructions


Add to my manuals
3 Pages

advertisement

American Standard T506.507.002 Moments FloWise Bath/Shower Trim Kits Installation Instructions | Manualzz

MOMENTS

BATH/SHOWER TRIM KIT

Installation

Instructions

T506.50X

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1

M968951 Rev. 1.4

Recommended Tools

Flat Blade Screwdriver

Adjustable Wrench

Pipe Wrench Plumbers' Putty or Caulking

Phillips Screwdriver

ROUGHING-IN DIMENSIONS

To assure proper positioning in relation to wall, note roughing-in dimensions.

3/4"" TO 2-3/8"

FINISHED WALL

1/2" NPT SHR. 1/2" NOM.

COPPER SWEAT

SWEAT

INLETS

INLETS

4-1/16"

5-5/8" REF.

2-3/8"

OPTIONAL TO FINISHED

FLOOR USUALLY

BETWEEN 65'' AND 80''

TUB 1/2" NOM.

COPPER SWEAT

8-1/8" REF.

"SEE ILLUSTRATION "

74" FOR

HEAD CLEARANCE

8-3/8" SHR

SWEAT

INLETS (STOPS)

SHR. 1/2" NOM.

COPPER SWEAT

TUB 1/2" NOM.

COPPER SWEAT

5-7/8"

TUB

18"

OPTIONAL

6-1/2"

3-3/8"

INLETS 1/2" NPT

Channel Locks

INLETS

1/2" NOM.

COPPER

SWEAT

2"

4-1/16"

4-1/16"

INLETS

1/2" NOM.

COPPER

SWEAT

OUTLETS

1/2" NPT

5-7/8"

1/2" NPT

1-1/2" REF.

3-3/8"

TOP OF

TUB RIM

BOTTOM OF

TUB

4"

OUTLETS

1/2" NPT

THREADED INLETS

3-3/8"

INLETS

1/2" NPT

THREADED INLETS (STOPS)

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

1

INSTALL VALVE TRIM

Figure 1. Remove plaster guard from valve. Push CAP (1) over VALVE CARTRIDGE (2) until seated against stop.

Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1) and attach with LONG SCREWS (4). Mount ESCUTCHEON

SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT

SCREWS (6).

Figure 3. Align PINS (7) on back side of ESCUTCHEON (8) with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5) and press ESCUTCHEON (8) flush against finished wall.

PLSTER

GUARD

Figure 1.

9

5

1

3

5

2

1

7

8

4

Figure 2.

Figure 3.

6

2

INSTALL TUB SPOUT, SHOWER HEAD,

SHOWER ARM WITH FLANGE

CAUTION: Protect finish on SHOWER

HEAD and TUB SPOUT when installing.

Remove pipe cap and plug from shower and tub rough piping.

Install SPOUT ESCUTCHEON (1) onto TUB SPOUT (2).

Apply sealant or Teflon tape to threads of tub filler nipple. Thread TUB SPOUT (2) onto tub nipple.

CAUTION: Protect finish on TUB SPOUT when installing.

Install SHOWER ESCUTCHEON (3) onto SHOWER

ARM (4). Apply sealant or Teflon tape to threads on both ends of SHOWER ARM (4) and thread longer leg of SHOWER ARM (4) into shower elbow.

Thread SHOWER HEAD (5) onto SHOWER ARM (4).

CAUTION: Protect finish on SHOWER HEAD and

ARM when installing.

5

3

4

2

SHR.

ELBOW

PIPE

PLUG

TUB FILLER

NIPPLE

.

1-1/2" REF

2

1

M968951 Rev. 1.4

3

ADJUST HOT LIMIT STOP

HOT LIMIT SAFETY STOP ADJUSTMENT

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT

SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT

SAFETY STOP.

4

Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1).

Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".

HANDLE INSTALLATION

INSTALL HANDLE ADAPTER

Push HANDLE ADAPTER (1) onto VALVE STEM (2).

Tighten set screw (3) with 2.5mm hex wrench supplied.

2

1

"RED RING"- HOT

LIMIT SAFETY STOP

"A"

0 1 2 3 4 5

6

"A"

ADJUSTMENT WHEN

WATER IS TOO HOT

PRY RED RING

FORWARD AND ROTATE

COUNTER-CLOCKWISE

ONE CLICK

TEMPERATURE

SETTING

NUMBERS

"B"

"B"

ADJUSTMENT WHEN

WATER IS TOO COLD

PRY RED RING

FORWARD AND

ROTATE CLOCKWISE

4a

INSTALL ADAPTER SCREW

With a flat blade screwdriver thread ADAPTER SCREW (4) into

HANDLE STEM ADAPTER (1) and tighten.

1

1

3

2.5MM HEX

WRENCH

4b

INSTALL ADPATER

With a flat blade screwdriver thread ADAPTER (5) onto SET SCREW (4) and tighten.

4

4c

INSTALL HANDLE

Align HANDLE (6) and install onto

HANDLE ADAPTER ASSEMBLY (7).

Tighten set screw (8) with 2.5mm

hex wrench supplied to secure HANDLE.

Push PLUG BUTTON (9) into set screw access hole in HANDLE (6).

6

8

7

9

2.5MM HEX

WRENCH

5

4

5

SERVICE

If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.

Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:

Remove HANDLE (1), CAP (2) and CARTRIDGE (4).

Clean inlets and MANIFOLD (5).

Reassemble CARTRIDGE (4), alternately tightening

SCREWS (3). Replace CAP (2) and HANDLE (1).

Check flow.

5

4

CARTRIDGE

INLETS

3

2

1

M968951 Rev. 1.4