27" Wide Electric Dryer

PRODUCT MODEL NUMBERS

MEDX700X

Electrical : This dryer requires a 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply

(or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Exhaust venting : Exhaust your dryer to the outside.

4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least

12" (305 mm) from the ground or any object that may be in the path of the exhaust.

Hood styles: A & B are recommended.

Dryer dimensions

OVERALL DIMENSIONS

43"

(1092 mm)

23¾"

(603 mm)

43"

(1092 mm)

13¾"

(349 mm)

*29 1 /

2

"

(749 mm)

*29 1 /

2

"

(749 mm)

A

27"

(687 mm)

B

27"

(687 mm)

A. Large opening side-swing door

B. Wide opening hamper door

The location must be large enough to allow the dryer door to open fully.

A B

Minimum required spacing for recessed or closet installation

18"*

(457 mm)

14" max.*

(356 mm)

48 in.

2 *

(310 cm ) 2

3"*

(76 mm)

A. Louvered hood

B. Box hood

C. Angled hood (acceptable)

C

The vent system chart provides venting requirments that will help to achieve the best drying performance.

Vent system chart:

NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.

Number of

90° turns or elbows

0

Vent System Chart

Type of vent

Rigid metal

Box/louvered hoods

64 ft. (20 m)

1

2

Angled hoods

58 ft. (17.7 m)

Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)

Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)

Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible.

27 ft. (8.2 m) 21 ft. (6.4 m)

Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need.

1"

(25 mm)

27"

(686 mm)

A

1"

(25 mm)

1"*

(25 mm)

29 ¼"

(743 mm)

B

5 ½"*

(140 mm)

24 in.

2 *

(155 cm ) 2

C

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Additional spacing recommended

3"*

(76 mm)

The dimensions shown following are for the minimum spacing allowed.

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Instructions packed with product. Specifications subject to change without notice.

Ref. W10115226B

01/2011