DEVI reg 535 thermostat Installation manual
DEVI DEVIreg 535 is a programmable thermostat designed for use with electric floor heating systems. It features precise temperature control, energy-saving modes, and various sensor options for optimal comfort and efficiency. With its user-friendly interface and customizable settings, DEVIreg 535 is an ideal choice for managing underfloor heating systems in residential and commercial applications.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Devireg™ 535
Installation manual
Warning!
This manual is only to be used by a professional installer to install and set up the thermostat properly.
It is not intended for the end-user!
INT
Congratulations with…
... your DEVI floor heating system.
Your property has been installed with a DEVI electric floor heating system. DEVI is Europe’s leading floor heating manufacturer, with over 45 years experience. We are confident that you will be satisfied with your new system.
DEVI brings you…
An Invisible heating solution - A concealed heat source opens up greater opportunities for decorating and furnishing.
Optimum comfort - DEVI brings you the luxury and comfort of a warm floor as well as a pleasant room temperature.
Floor heating is the most comfortable type of heating because it is based on the fact that warmth travels upwards; pleasant warmth for your feet, body and head.
Low running costs – Thanks to the precise DEVI thermostat and the placement of the heating elements right under the floor surface the heat can be controlled optimally in order for you to have the comfort you desire with minimal energy use. Moreover electric floor heating is practically maintenance free, in total keeping down the running costs.
A long lasting solution - We back-up our floor heating solutions with a ten year guarantee on all our mats and cables, and a two year warranty on our thermostats. Practically speaking you can count on DEVI heating cables and mats lasting as long as the house in which they are installed – and that is without having to maintain them.
Hygiene - As DEVI produce floor heating systems, only very gentle air is circulating, and the amount of travelling dust particles is reduced considerably; a great relief for people with allergies or asthma. There are also no dangerous fumes such as carbon monoxide generated by the system.
2
Install & configure the thermostat
Placement of Devireg™ 535
When Devireg™ 535 is used as a room sensor, installation height should typically be between 80-150 cm.
INT
In wet rooms it should be installed on an even surface, according to local building regulations.
At least 50 cm away from windows/doors that will be left open occasionally.
Not on a wall where it will be subjected to direct sunlight.
Not on the inner side of a wall facing the outside.
3
Installation and connection
Installation of Devireg™ 535
1. To remove the front cover, gently press the release tabs under the bottom of the thermostat with a screwdriver.
Then remove the front.
Removing the front cover and pushing the installation button, is not intended to be done by anyone else but a qualified installer!
2. Connect the thermostat according to the connection diagram
Mains
180-250V~
N L
Max.
Load
15 A
NO CONNECT
N
N
Load
L
L
Load
NTC
The screen of the heating cable must be connected via a terminal strip to the earth wire of the supply cable.
4
Choose sensor combination
3. Choose sensor combination
When installing the Devireg™ 535 you need to choose the type of heating and thus which sensors should be used. You have three options:
Comfort heating: Constant temperature on the floor in bathrooms and other rooms where a comfortable warm surface is required.
Install the Floor sensor and choose only the Floor sensor.
INT
Total heating: Control of room temperature in living rooms etc. Install the Floor sensor and choose both
Floor sensor and Room sensor.
No floor sensor: A floor sensor is not present, and cannot be installed. Choose Room sensor. (Not recommended).
Be aware that without a floor sensor, the temperature control can be less accurate, and overheating of the floor is of higher risk.
DEVI recommends that a floor sensor is always installed.
When the thermostat is used to control a floor heating element according to EN/IEC 60335-1 and
EN/IEC 60335-2-96, always use the floor sensor and never set the temperature limit above 35°C.
5
Configuration - sensor
Selection of sensor type
Power on the thermostat.
With the front off, with a small screwdriver, pencil, or needle press the installation button.
Select the sensors to be used for the heating system:
Devireg TM 535 is able to use two sensors:
- a built-in room sensor
- an external sensor to be placed
in the floor.
This gives 3 options:
floor sensor.
room sensor.
both room and floor sensor.
Always use floor sensor or a room
+ floor sensor combination when used to control floor heating
The default is
To change this setting, press • and use the arrow buttons ▲▼ to select your choice. Press • to accept your choice.
If you have selected room sensor only, the installation procedure is complete. Press installation button to accept. (Go to page 9).
If you have selected floor sensor or a combination of room- and floor sensor press ▲▼ for the next setting.
6
Configuration - Max. floor temp.
Maximum floor temperature.
When selecting either floor sensor or floor and room sensors, next screen is maximum floor temperature.
Default setting is 35°C.
To change this setting, press • and use the arrow buttons ▲▼ to select your choice. Press • to accept your choice.
If you have selected a combination of room and floor sensor, the installation procedure is complete.
Press installation button to accept.
(Go to page 9)
If you have selected floor sensor only press ▲▼ for the next setting.
INT
When the thermostat is used to control a floor heating element according to EN/IEC 60335-1 and
EN/IEC 60335-2-96, always use the floor sensor and never set the temperature limit above 35°C.
Notice:
The floor temperature is measured where the sensor is placed. The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top. Floor manufactures often specify the max. temperature on the top surface of the floor.
Please contact your floor supplier for maximum surface temperature.
7
Configuration - Scale
Scale
If you select Devireg TM 535 to only use a floor sensor, mode , you have to select the display type. The choice is either numerical scale 1-6 or Celcius scale 5° to 45°.
Default is Celcius scale. When selecting Celcius, the display will show the actual temperature at the floor sensor.
To change this setting, press • and use the arrow buttons ▲▼ to select your choice.
Press • to accept your choice.
The installation procedure is now finished.
You can use the ▲▼ for going back or forward through the settings.
Otherwise:
Press the installation pinhole to exit installation mode.
4. Put the frame and front back on.
Initially mains supply the thermostat for 15 hours to fully charge the battery. The current time and day
is then kept for 80 days if mains supply is off.
All other settings are stored permanently.
8
Trouble shooting
Clock symbol flashing:
Time settings were lost due to power cut.
The thermostat resumes to manual mode.
E4 flashing in display:
Error code 4 – The thermostat has overheated and has switched off
Let the thermostat cool for period. Then switch the thermostat off and on.
E5 or E6 flashing in display:
Error code 5 - Floor sensor short circuited.
Error code 6 - Floor sensor disconnected.
Check connections, if they are OK, then disconnect the 2 sensor wires and connect an ohm meter to sensor wires.
Measure the ohm value and check with the values in the table in Technical Specifications below.
INT
Light Indications (LED)
The Devireg TM 535 has a LED above the 2 pole safety switch.
The LED has five indications:
No light The system is turned off.
Green light System is standing by, set point temperature reached
Green light flashing Floor sensor is defect
Red light
Switching between red and green light
System is heating
The floor temperature limit prevents the set point room temperature from being reached.
9
Technical specifications
Operation voltage 180-250 VAC, 50/60 Hz
Standby power consumption
Max. 0.30 W
Relay:
• Resistive load
• Inductive load
230V ~ 15A / 3450W cos φ= 0.3 Max. 4A
Sensing unit
Sensing values:
• 0°C
• 20°C
• 50°C
Hysteresis
NTC 15 kOhm at 25°C
42 kOhm
18 kOhm
6 kOhm
± 0.2°C with room sensor,
± 0.4°C with floor sensor only
-10° to +30°C Ambient temperature
Frost protection 5°C
Temperature range 5-35°C with room sensor,
5-45°C with floor sensor only.
When used together with electrical floor heating elements, according to
EN/IEC 60335-2-96 never adjust floor temperature above 35°C.
Floor max. 20-50°C.
Floor min. 10-35°C only when installed with room and floor sensor combination.
Sensor failure monitoring
The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or short-circuited
IP class
Dimensions
31
85 mm x 85 mm
10
Disposal Instruction
INT
11
Article No.: 08095880
Version - 02
DEVI A/S
Ulvehavevej 61
DK-7100 Vejle
Tel: +45 74 88 85 00
Fax: +45 74 88 85 01 www.devi.com
advertisement
Key Features
- Comfort heating, total heating, or no floor sensor mode
- User-friendly interface
- Frost protection
- Temperature limit setting