advertisement
Declaration of Conformity
(As referred to in Annex IV 2. of Directive 2004/108/EC)
Declares under his sole responsibility that the produced Echo Sounder manufactured by
Koden Electronics Co., Ltd.
5278 Uenohara
Uenohara-Shi
,
Yamanashi-Ken
409-0112, Japan
Telephone +81 554 20 5860 Telefax +81 554 20 5875
Identified by the type number
CVS-128
to which this declaration refers conforms to the relevant essential requirements of Directive 2004/108/EC and is in conformity with the EMC requirements of EU harmonised standard
EN 60945: 2002 (Clauses 9, 10 & 12)
Authorised representative in Europe
Heinz Hoghoff
Koden Elektronik GmbH.
Am Gewerbepark 15
D-64823, Gross–Umstadt
Germany.
Phone +49 6078 2056
Telefax+49 6078 73824
Signed
Heinz Hoghoff,
Dated 15 April 2009
N.B. As this product is for Maritime use compliance with Directive 72/23/EEC is not required.
Declaration of Conformity
(As referred to in Annex IV 2. of Directive 2004/108/EC)
Declares under his sole responsibility that the produced Echo Sounder manufactured by
Koden Electronics Co., Ltd.
5278 Uenohara
Uenohara-Shi
,
Yamanashi-Ken
409-0112, Japan
Telephone +81 554 20 5860 Telefax 554
Identified by the type number
CVS-128B
to which this declaration refers conforms to the relevant essential requirements of Directive 2004/108/EC and is in conformity with the EMC requirements of EU harmonised standard
EN 60945: 2002 ( Clauses 9,10 & 12 )
Authorised representative in Europe
Heinz Hoghoff
Koden Elektronik GmbH.
Am Gewerbepark 15
D-64823, Gross–Umstadt
Germany.
Phone +49 6078 2056
Telefax+49 6078 73824
Signed :
Heinz Hoghoff,
Dated : 01 Jun. 2012 Document No. 72-2731U-X003
N.B. As this product is for Maritime use compliance with Directive 72/23/EEC is not required.
CVS-128/128B Revision History
CVS-128/128B Operation Manual
Doc No. 0093112802
Document Revision History
No. Doc. No-Rev. No. Reviced Date Revised Content
(Y/M/D)
0 0093112802-00 2009/05/27 First
1 0093112802-01 2009/07/09 Chapter
2
4
0093112802-02
0093112802-04
2010/01/12 Revision (From software KM-E79* Ver01.03 to Ver01.**)
3 0093112802-03 2011/04/27
Revision (From software KM-E79 Ver01.06 to Ver01.**)
System Configuration, Configuration of Equipment,
Chapter 5, Wording
2011/12/26 Important Notice, Chapter 2, Chapter 6
5 0093112802-05 2012/06/15
6 0093112802-06 2013/06/24
7
Added CVS-128B
Revision (From software KM-E79 Ver01.08 to Ver01.**)
Revision (From software KM-F22* Ver01.02 to Ver01.**)
System Configuration, Configuration of Equipment,
Chapter 5
8
9
10
*KM-E79: CVS-128, KM-F22: CVS-128B
**Subject to version change
Document No. Revised Version Norm
When part of the document needs to be revised, the document has advanced revision number.
The document No. is indicated at the lower right side on the cover and at the left or right side of the footer region of each page.
© 2009-2013 Koden Electronics Co., Ltd. All rights reserved.
No part of this publication may be reproduced, transmitted, translated in any from by any means without the written permission of Koden Electronics Co., Ltd. The technical descriptions contained in this publication are subject to change without notice. Koden assumes no responsibility for any errors, incidentals or consequential damages caused by misinterpretation of the descriptions contained in this publication.
0093112802-06 i
Important Notice CVS-128/128B
Important Notice
For copy and transcription of this Operation Manual (hereinafter referred to as this manual), permission from Koden is needed. Koden prohibits the un-authorized copy and transcription of this manual.
If this manual is lost or damaged, consult a dealer of Koden or Koden.
The specification of the products and the contents in this manual are subject to change without notice.
The contents displayed on the menu of product may be different from the expression of this manual. The fonts and shapes of the keys and menus in the illustration may differ from the actual ones, and some parts may be omitted.
Koden is not liable for damages and troubles arisen from misunderstanding of the contents in this manual.
Koden is not liable for any damages caused by earthquake, lightning, wind and flood damage and fire for which Koden is not responsible, and actions by third parties, other accidents, customer’s unintended error/abuse and the use under other abnormal conditions.
Koden is not liable for damages of accompaniment (change/loss of memorized content, loss of business profit, stop of business) arisen from use or failure of our products.
If the stored data are changed or lost, irrespective of causes of troubles and damages, Koden is not liable for them.
Koden is not liable for any damages arisen from malfunction caused by combination of software and connected equipment in which Koden is not engaged
.
CVS-128/128B For Your Safe Operation
For Your Safe Operation
Pictorial used in this Operation Manual
This Operation Manual uses the following pictorials. Understand the meaning of each pictorial and implement the maintenance and inspection.
Symbol Meaning
Mark for warning
This symbol denotes that there is a risk of death or serious injury when not dealing with it correctly.
Mark for danger high voltage
This symbol denotes that there is a risk of death or serious injury caused by electric shock when not dealing with it correctly.
Mark for caution
This symbol denotes that there is a risk of slight injury or damage of device when not dealing with it correctly.
Mark for prohibition
This symbol denotes prohibition of the specified conduct. Description of the prohibition is displayed near the mark.
Caution Item on Equipment
Be careful of a high voltage inside.
A high voltage, which may risk your life, is used. This high voltage remains in the circuit after you have powered off switch. To prevent touching the high voltage circuit inadvertently, the hard cover is provided to the high voltage circuit and the high voltage caution label is affixed. Ensure to power off switch for your safety and discharge the electricity remaining in the capacity before starting to check. An engineer authorized by our company should inspect and maintain
Be sure to power off in the boat.
If the power switch is inadvertently powered on during work, you will be electrified. To prevent such accident from occurring, ensure to power off in the boat and the power of equipment. Furthermore, it is safer to hang the caution tag described as [Under Work] near the power switch of equipment.
Be careful of dust
Inhaling dust may cause A respiratory disease. When cleaning the inside of equipment, be careful not to inhale dust. Wearing a safety mask is recommended.
0093112802-06 iii
For Your Safe Operation CVS-128/128B
Caution on location of equipment
Do not install the equipment where it is excessively damp and suffers from excessive water drops.
Escaping from static electricity
The static electricity may be generated from the carpet on the floor in the cabin or clothes made of synthetic fiber. The static electricity may destroy the electronic parts on the circuit board. Handle the circuit board, taking the measure of static electricity free.
Install the transducer at the location where it is not affected by bubble and noise The bubble and noise seriously degrade the performance of this unit.
Caution Item on Handling
Do not disassemble or modify. It may leads to trouble, fire, smoking or electric shock. In case of trouble, contact our dealer or our company.
In case of smoke or fire, boat power off and the power of this unit. It may cause fire, electric shock or damage.
Be cautious of remaining high voltage.
A high voltage may remain in the capacitor for several minutes after you have powered off. Before inspecting inside, wait at least 5 minutes after powering off or discharge the remaining electricity in an appropriate manner.
Then, start the work.
The information displayed in this unit is not provided directly for your navigation. For your navigation, be sure to see the specified material.
Use the specified fuse. If un-specified fuse is used, it may cause a fire, smoke or damage.
Whenever transmitting, be sure to submerge the transducer in water first. If transmitted without submerging the transducer, it may be damaged.
CVS-128/128B Contents
Contents
Document Revision History ....................... i
Important Notice ....................................... ii
For Your Safe Operation ......................... iii
Contents ................................................... v
Introduction ................................................ ix
System Configuration ................................. x
Configuration of Equipment ....................... xi
Setting the range switching to auto range .......................................... 1-9
Setting the range switching to
Manual range ............................. 1-9
1.7 Setting Shift ............................ 1-9
Setting of Manual Shift ............... 1-9
Release of manual Shift ........... 1-10
Setting of Auto Shift ................. 1-10
Change the frequency ............................. xiv
Chapter 1 Basic Operation ...................... 1-1
1.1 How to use the key .................... 1-1
How to remove the hard cover ... 1-2
When removing the
CVS-128/128B Display unit ....... 1-2
The clean of CVS-128/128B
Display unit ................................ 1-2
Power on .................................... 1-3
Power off .................................... 1-3
Alarm of Power Voltage ............. 1-3
Adjustment of LCD Brilliance ..... 1-4
Brightness Adjustment of Panel
Brilliance .................................... 1-4
1.4 Switch-over of Display mode ..... 1-4
Normal Image (Low frequency,
High frequency) .......................... 1-4
Dual frequency ........................... 1-5
Zoom (Low frequency, High frequency) .................................. 1-5
Navigation Menu (NAV1, NAV2) 1-7
1.5 Selection of NAV Display ........... 1-8
Type of NAV Display .................. 1-8
Selection of NAV Menu .............. 1-8
1.6 Switch-over of Range ................ 1-9
Basic Operation of Gain ........... 1-11
Selecting the auto gain ............ 1-11
Adjusting the gain by auto ....... 1-11
Selecting the manual gain ....... 1-11
Manual adjustment of the gain . 1-11
1.9 Use of [EVENT] key ................. 1-12
Selecting the event key function1-12
Presetting the waypoint ........... 1-12
Store the image ........................ 1-13
Fishing hot spot ........................ 1-13
1.10 Use of [F1] / [F2] key ................ 1-14
Selecting the
[F1] / [F2] key ......................... 1-14
Preset of [F1] / [F2] key ........... 1-14
1.11 Operation of VRM .................... 1-15
1.12 Display of fish information ........ 1-15
Display the fish symbol /Stop the display of fish symbol ............... 1-16
Selecting the symbol info ......... 1-16
Fish symbol detection adjustment ............................... 1-16
Size adjustment ....................... 1-16
Big fish / Big fish color ............. 1-17
Points to note in use of fish symbol ...................................... 1-17
Chapter 2 How to use the Menu ............. 2-1
2.1 How to operate the menu .......... 2-1
0093112802-06 v
Contents
Display the menu / Stop the display of menu .......................... 2-1
Menu Operation ......................... 2-1
2.2 Changing of Image Speed.......... 2-2
2.3 Rejection of Interference ............ 2-2
Interference Rejection ................ 2-2
2.4 Color Rejection of Weak Echo ... 2-3
Color Rejection ........................... 2-3
2.5 Rejection Noise
Noise Rejection .......................... 2-3
2.6 Setting of Shift step .................... 2-3
2.7 Selection of Zoom ...................... 2-3
2.8 Setting of Zoom Range .............. 2-4
2.9 Setting of Zoom Start ................. 2-4
2.10 Preset of Range ......................... 2-4
Easy registration method of the range .................................... 2-5
2.11 Setting of Background Color ...... 2-5
2.12 Setting of White Line .................. 2-5
Stopping the alarm sound .......... 2-6
Setting the alarm ........................ 2-7
Release the alarm ...................... 2-7
Confirm the alarm state .............. 2-7
2.14 Preset/ WPT edit/ WPT delete of
Waypoint .................................... 2-8
NAV Start .................................... 2-8
Cancel the NAV .......................... 2-8
Edit the destination ..................... 2-8
Delete the waypoint .................... 2-9
Recall the stored image and preset it as a destination ............ 2-9
2.15 Store/Recall/Deletion of Image 2-10
Store the image ........................ 2-10
Recall the stored image ........... 2-10
Delete the stored image ........... 2-11
Add the comment to the stored image ........................................ 2-11
2.16 Explanation of Sonar ................ 2-12
CVS-128/128B
Switch-over of Sona-Tone
TM
..... 2-12
Connection of External
Speaker .................................... 2-12
2.17 Explanation of Menu Item ........ 2-12
Inner-hull .................................. 2-12
TVG .......................................... 2-13
Change the TX power .............. 2-13
Change the Pulse width ........... 2-13
Change the Bandwidth ............. 2-14
D. Range .................................. 2-14
Display Width ........................... 2-14
Display the A scope / Stop the display of A scope .................... 2-14
Change the display color of echo sounder image ......................... 2-14
Change the depth value ........... 2-15
Display the depth unit / Stop the display of depth unit ................. 2-15
Display the water temp graph /
Stop the display of water temp graph ........................................ 2-15
Setting of the background color of
NAV display .............................. 2-15
Setting of the echo sounder display at NAV display .............. 2-15
Image Swap ............................. 2-15
Display the Operation guide /
Stop the display of Operation guide ......................................... 2-15
Display the detection area /
Stop the display of detection area .......................................... 2-16
Setting of Scale display ............ 2-16
Change the scale value ............ 2-16
Change the image direction ..... 2-16
Setting of Depth measurement 2-16
Change the display color.......... 2-16
Setting of Key lock ................... 2-17
Change the scale type ............. 2-17
CVS-128/128B Contents
Change the bottom color ......... 2-17
Change the image partition ...... 2-17
Display the frequency / Stop the display of frequency ................. 2-17
Selecting a display area of fish symbol indication ..................... 2-17
Chapter 3 How to use the menu2 ............ 3-1
3.1 Display of Menu ......................... 3-1
Display the menu ....................... 3-1
Return to the normal menu ........ 3-1
3.2 Setting of External Input/Output . 3-1
Buzzer Setting ............................ 3-1
Temp Source .............................. 3-1
Speed Source ............................ 3-1
Baud Rate .................................. 3-1
NMEA Monitor ............................ 3-2
NMEA Output Data .................... 3-2
3.3 Setting of Correction Item .......... 3-2
Draft Set ..................................... 3-2
Sonic Speed ............................... 3-2
Water Temp ................................ 3-2
Boat Speed ................................ 3-2
Directivity angle (Low/High) ....... 3-2
Bubble ........................................ 3-3
Bubble time set .......................... 3-3
3.4 Setting of Basic Set Item ........... 3-3
Language ................................... 3-3
Range & Speed Unit .................. 3-3
Depth Unit .................................. 3-3
Temperature Unit ....................... 3-3
Local time Offset ........................ 3-3
GPS select ................................. 3-3
GPS initialize .............................. 3-3
Simulation .................................. 3-3
Slide show .................................. 3-4
Initialize ...................................... 3-4
System Check ............................ 3-4
All WPTs deletes ........................ 3-4
All stored image deletes ............ 3-4
Bottom start ................................ 3-4
Past image ................................. 3-4
Inner-hull .................................... 3-4
TD select .................................... 3-4
3.6 Setting of Adjust2 Item ............... 3-4
STC strength adjust Low / High . 3-4
STC depth adjust Low / High ..... 3-4
Color adjust ................................ 3 -5
Image speed adjust.................... 3-5
Bottom limit ................................ 3-5
Sounding .................................... 3-5
Frequency select (Low / High) ... 3-5
Power frequency adjustment ..... 3-5
Chapter 4 Maintenance and Inspection .. 4-1
CVS-128/128B Display unit ....... 4-1
Transducer ................................. 4-1
4.4 If you suspect a trouble .............. 4-2
Diagnose .................................... 4-3
Confirm the version .................... 4-3
Return to the menu .................... 4-3
Chapter 5 Installation .............................. 5-1
5.1 Items of Caution on Installation . 5-1
Unpacking the components ....... 5-1
Inspection of components and accessories ................................ 5-1
Decision of Installing Location ... 5-1
Laying and Connection of Cable 5-2
Confirmation after Installation .... 5-2
5.2 Installation of CVS-128/128B
Display unit ................................ 5-3
Desk-top Installation .................. 5-3
0093112802-06 vii
Contents
Flush-mount Installation ............. 5-5
5.3 Installation Transducer
In case of Inner-hull .................... 5-6
In case of Through hull ............... 5-7
Connection of Cable to
CVS-128/128B Display unit........ 5-8
Pin Assignment of Rear
Connector ................................... 5-8
Connection of Power Cable ....... 5-9
Connection of Transducer ........ 5-10
Connection with external equipment................................. 5-11
Connection with GPS-20A ....... 5-11
Connection with Speed Sensor or
Water Temperature Sensor
(Option) .................................... 5-12
Connection of External Speaker for Sona-Tone
TM
(Prepared by a customer) ........ 5-13
Connection of External Monitor
(J7) (Prepared by a customer) . 5-13
Input Data ................................. 5-14
Output Data .............................. 5-14
Chapter 6 Table Attached ........................ 6-1
6.3 Appearance ................................ 6-7
CVS-128/128B
CVS-128/128B Introduction
Introduction
The CVS-128/128B is a Dual frequency Color LCD display echo sounder.
This unit equipped with digital process displays the circumstance in the water under all conditions, matching with the high luminance 8.4 inch LCD.
The main features of this unit are as follows:
With the digital reception process, the compatibility of the high resolution in a shallow depth and the noise rejection capability in a deep depth are established. The auto mode function provides the best image.
The high-performance LCD maintains high visibility under any conditions.
The unit can be installed in an open bridge and is highly waterproof.
Sona-Tone (Sonar sound) function is equipped with for catching situations schools of fish and others by sound.
Up to 10 images can be stored. If you connect the optional GPS, the fishing hot spot function, that directs your boat to navigate easily to the location desired, is available by marking the event mark when recalling the stored image.
With the adoption of a specific filter (AR coat), an image can be seen clearly, refusing sunshine.
The countermeasures against the reflection on the LCD screen and dew are provided.
The various alarm functions are available. (Bottom, school of fish, water temperature*, boat speed*, arrival*, XTE*, power) (Note: The mark * denotes that the connection of option is mandatory)
When flush-mounting, the unit can be easily installed from front side.
The RGB output for an external monitor is provided as standard equipment. The use of the external monitor enables you to observe easily the echo sounder screen at a location which is remote from a main unit. (External monitor: Prepared by a customer)
CVS-128B is the high sensitivity model with broadband transducer. This model can be used at your optimum frequencies within the specification of the broadband transducer. You can set 2 frequencies depending on a target fish or intended purpose during operation.
0093112802-06 ix
System Configuration CVS-128/128B
System Configuration
Connection Diagram
CVS-128/128B Display unit
With mounting bracket and hard cover
To Transducer connector
(J6 connector)
CW-840-0.3M
To External monitor connector
(J7 connector)
To POWER connector
CW-576-0.5M
CW-264A-2M
Legend
Standard configuration
Option
Owner supply
External monitor
( Owner supply )
External power output (For GPS etc)
External speaker (For speaker with amplifier)
( Owner supply )
Red
+
Black
-
NMEA circuit input output
External navigation equipment
, external water temperature meter
10.8 to 31.2VDC
Connection to the speed sensor
Connection to the water
Temperature
Water temperature sensor
/ speed sensor
ST-80/90/100
Connection to the Transducer
Note: To use the water temperature sensor / speed sensor,
The wiring of transducer connector has to be changed.
CVS-128
Transducer TD-501C (Dual frequency combination type 50 / 200 kHz)
Rubber mold made. Equipped with Inner-hull/Ship’s bottom/Ship’s side.
Transducer TD-500T-3B / 501T-3B (Dual frequency combination type 50 / 200 kHz)
Bronze made. Equipped with Through-hull.
Transducer TD-500T-2B (Dual frequency combination type 50 / 200 kHz)
Plastic made. Equipped with Inner-hull.
CVS-128
Transducer P66 (Dual frequency combination type 50 / 200 kHz)
Plastic made. Equipped with Transom. (Owner supply)
CVS-128B
Transducer TDM-071 (38 to 75 kHz)
Transducer TDM-091D (42 to 65 kHz) (130 to 210 kHz)
Urethane mold made. Equipped with Ship’s bottom/Ship’s side
CVS-128/128B
Configuration of Equipment
Standard Equipment Configuration List
No. Name of item Type
CVS-128/128B
Configuration of Equipment
Remark
With mounting bracket and knob
Weight/
Length
3.2 kg
Quantity
1
E57MB11060
3 DC power cable
(Combined cable)
CW-264A-2M With 12 connector at one end/ un-treated at the other end
2 m 1
4 Fuse F-7161-3A
Cylinder (ø 6.4x30)
Normal fusion type for main power
2
5 Cap LTWCAP-DABCFXC1 For transducer cable connector
1
6 Operation CVS-128.OM.E
CVS-128.QR.E
English
English
CVS-SER.RM.E English
Essential Option
No. Name of item
1 Transducer
Type Remark
Type of transducer transducer cable (with connector at one end)
1
1
1
Weight/
Length
Quantity
1
0093112802-06 xi
Configuration of Equipment CVS-128/128B
Type of transducer
1
TD-500T-2B CVS-128
50/200 kHz
600 W
Mounting method
Length of the cable
Plastic
9m
Inner-hull
Beam width
(Right and left x back and forth)
50kHz
50°x50° ( -6dB)
200kHz
17°x17° ( -6dB)
2
3
TD-500T-3B
TD-501C
CVS-128
50/200 kHz
600 W
CVS-128
50/200 kHz
1 kW
Bronze
9m
Rubber mold
10m
Through-hull 50kHz
50°x50° ( -6dB)
200kHz
17°x17° ( -6dB)
Inner-hull/
Ship’s bottom/
Ship’s side
(The CW-840-0.3M is needed)
50kHz
58°x20° ( -6dB)
200kHz
17°x 6° ( -6dB)
4
TD-501T-3B CVS-128
50/200 kHz
1 kW
Bronze
9m
Through-hull 50kHz
20°x22° ( -6dB)
200kHz
5°x 5° ( -6dB)
5
6
TDM-071
TDM-091D
CVS-128B
38 to 75 kHz
Urethane mold
15m
CVS-128B
42 to 65 kHz
130 to210kHz
Urethane mold
15m
Through-hull
Ship’s bottom/
Ship’s side
With water temperature sensor.
Through-hull
Ship’s bottom/
Ship’s side
With water temperature sensor.
38kHz
30°x20° ( -6dB)
75kHz
16°x 10° ( -6dB)
42kHz
35° ( -6dB)
65kHz
22° ( -6dB)
130kHz
14° ( -6dB)
210kHz
8° ( -6dB)
Caution: For Inner-hull installation, an Inner-hull kit is necessary.
AIRMAR’s Transducer model P66 is also applicable. (Owner supply)
1
P66 CVS-128
50/200 kHz
600 W
Plastic
10m
Transom
With water temperature sensor and speed sensor.
(The CW-840-0.3M is needed)
50kHz
69°x69° ( -6dB)
200kHz
16°x16° ( -6dB)
CVS-128/128B Configuration of Equipment
Option List
No. Name of Item sensor/speed sensor
Specification
ST-80
ST-90
ST-100
Remark
For transom mounting
Plastic made (with cable)
For through-hull mounting
Plastic made (with cable)
For through-hull mounting
Bronze made (with cable)
Weight/Length
0.3 kg / 9 m
0.6 kg / 9 m
1.2 kg / 9 m
3
4
5
6
Inner-hull kit
Cable for transducer
Connector for GPS sensor
Cable for external monitor
GPS-20A-10M-B
[KODEN]
MFB-04
MFB-04W
CW-840-0.3M
For GPS measuring
(With power & signal cable)
Plastic made for installing the transducer TD-500T-2B
Plastic made for installing the transducer TD-501C
Needed when using the optional water temperature sensor / speed sensor.
LTWBD-06PMMP-LC Needed when using the
GPS-20A (Type B) sensor.
CW-576-0.5M Junction cable for connection of external monitor
0.25 kg / 10 m
1.3 kg
1.3 kg
30 cm
0.5 m
0093112802-06 xiii
Change the frequency CVS-128/128B
Change the frequency
CVS-128B is used with the other transducer please make sure to set the below items manually in line with the transducer installed.
Caution: The transducer may be damaged if the settings are wrong.
Caution: There are occasions too much noise is generated in a particular frequency to
be connected.
Caution: Fish symbol operation cannot be generated at the other frequencies than the high frequency of 200 kHz and the low frequency of 50 kHz.
Setting of Output Frequency (CVS-128B)
1
Press the [MENU] key.
2
Select [Freq]
[Freq select (L)]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Set the output frequency at the low frequency side. (Press the [ ] key or [ ] key)
5
Set the high frequency also in the same way as for the low frequency side, in reference to the step
2 to 4.
6
Press the [MENU] key. Then, the edit is finished.
Caution: When single transducer is connected, set the same frequencies for low and
high.
Setting of Power Frequency (CVS-128B)
1
Press the [MENU] key.
2
Select [Freq]
[Power freq adj]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Set the power supply frequency. (Press the [ ] key or [ ] key)
The recommended power supply frequency for Dual frequency (50 kHz/200 kHz): 107.0 kHz
Transmit frequency
Recommended power supply frequency
Transmit frequency
Recommended power supply frequency
28 kHz 115.0 kHz 70 kHz 106.5 kHz
38 kHz
40 kHz
55 kHz
105.0 kHz
123.0 kHz
107.0 kHz
75 kHz
120 kHz
-
103.5 kHz
109.0 kHz
-
Caution: There may be much noise on the screen even for the recommended power supply frequency depending on the transducer. In this case, set the power supply frequency to reduce the noise on the screen.
Caution: Set the power supply frequency to reduce the noise on the screen, when the other transmission frequency than above is used.
CVS-128/128B Change the frequency
5
Press the [MENU] key. Then, the edit is finished.
Adjustment of bottom detection
When the bottom can't be detected or when the bottom is of mud pool or seaweed, [Gain (TD)] shall be turned up. When transfer to fish schools, etc. frequently occurs, [Gain (TD)] shall be turned down.
1
Press the [MENU] key.
2
Select [Adjust]
[Gain(TD)]. (See [2.1 How to operate the menu])
3
Press the [ ] key. The image displays bottom only. It may show very strong fish targets.
4
Set a value to display the sea bottom continuously without interruption. For high frequency, turn
[GAIN (HF) knob] and for low frequency, turn [GAIN (LF) knob]
After the alteration of setting, please confirm the condition for some time.
Those adjustments are recommended to be performed at the site of use.
L: 6.0 H: 6.0 R:M 12.0V
Gain (TD) L
Gain (TD) H
Gain (TD)
Bottom
5
Press the [MENU] key. Then, the edit is finished.
0093112802-06 xv
CVS-128/128B
Chapter 1 Basic Operation
1.1 How to use the key
CVS-128/128B Display unit
Chapter 1 Basic Operation
1
2
3
4
5
6
7
8
9
10
Various setting can be done directly. The menu list closes automatically after the key operation of the other keys than [menu].
No. Key Explanation
1 [F1]
2 [EVENT]
Recalls directly the item preset.
Notifies the external equipment of the present position. Presets the menu. It begins a fishing hot spot.
3
4
[Cursor]
▲ ▼
[MENU]
Selects the menu item. Changes the set value.
Moves the VRM marker. Moves the marker for notifying the event.Changes the shift.
Opens or closes the menu.
5 [F2] Recalls directly the item preset.
6 [
▲
RANGE
▼
] Changes the range setting.
7
8
9
10
[GAIN(HF)
Knob]
[GAIN(LF)
Knob]
[DISP]
[BRILL ]/
Power
Rotate: Changes the gain value.
Press: Recalls the gain select.
Rotate: Changes the gain value.
Press: Recalls the gain select.
Switches to the High frequency or Low frequency of echo sounder image, zoom and navigation menu.
Press: Power on. Adjusts the brilliance and brightness of panel.
Long-press: Power off.
0093112802-06 1-1
Chapter 1 Basic Operation CVS-128/128B
How to remove the hard cover
While widening the claws at right and left sides of hard cover, draw the hard cover towards you.
Claw
When removing CVS-128/128B Display unit
To prevent dust from entering, cap the connector at the rear of CVS-128/128B Display unit and the power cable with caps.
Install the supplied cap to the transducer cable as shown in the figure and cap it.
Caution: Do not pull the cable strongly. If you do so, it will be broken.
The clean of CVS-128/128B Display unit
The cleaning of the display unit goes after removing the front-frame. After removing the front-frame, use a synthetic detergent and OA cleaner and wipe the display unit lightly. Then dry sufficiently, and return the front- frame to original position.
Caution: The display unit has a special coating. Do not use a solvent such as paint thinner, acetone, alcohol, and benzene, etc.
Caution: Strong rubbing may cause bruising and scratching.
CVS-128/128B Chapter 1 Basic Operation
1.2 Power On/Off
Power on
1
Press the [BRILL ] key to power on.
The startup menu is displayed. When started up, the internal memories (ROM,
RAM) are automatically checked. When checking is normally finished, the menu below is displayed.
Caution: If an error occurs in the memory check, the LED on the operation panel blinks. The unit may be not function normally. If you suspect trouble, contact the dealer of your purchase or our company.
2
Language Selection at Initial Startup.
When powering on first, the [Language] menu is displayed.
Language
English
日本語
Select the language with [ ] key or [ ] key.
(The language can be selected by rotating the
[GAIN (HF) Knob] or [GAIN (LF) Knob].)
3
When the installation of a transducer is
[Inner-hull], select the [Yes].
Inner-hull
No
Yes
Press [ ] and [ the [Yes ] .
] keys in sequence, and select
4
Press the [MENU] key to decide the language and the inner-hull.
5
After a few seconds, the menu sets the screen as selected in [DISP].
Caution: In addition to English, Japanese, there are several compatible languages.
Explanation of the display:
Rainbow pattern
Time mark
L
Gain
Power supply voltage
Range
Alarm icon
H
Function icon
Event icon
Oscillation line
Schools of fish
Fish
Type of Gain
H: High frequency gain
L: Low frequency gain
Depth
Type of Range
R: M: Manual Range
R: A: Auto Range
R: AS: Auto Shift
Power off
1
When powering off, keep pressing the
[BRILL ] key for 3 seconds.
The remaining time for the power to shut off is displayed on the menu.
Alarm of Power Voltage
If detecting the malfunction of the voltage, the
icon blinks and the alarm beeps.
Caution: In case of the low voltage or the high voltage, it shuts down. The precision of Power Voltage is ± 0.5 V.
0093112802-06 1-3
Chapter 1 Basic Operation CVS-128/128B
1.3 LCD Brilliance Adjustment
Adjustment of LCD Brilliance
The brilliance of the display can be adjusted to facilitate visualization.
The [Lcd brill] and [Panel brill] can be switched every time when pressing the [BRILL ] key.
1
Press the [BRILL ] key for a short period of time to display the menu ([Lcd brill]).
2
Rotate the [GAIN (HF) Knob] or [GAIN (LF)
Knob]. When “1” is selected, it is darkest.
When “10” is selected, it is brightest.
Lcd brill
10
3
Press the [MENU] key to close the menu.
Brightness Adjustment of Panel
Brilliance
The brightness of panel can be adjusted.
The [Lcd brill] and [Panel brill] can be switched every time when pressing the [BRILL ] key.
1
Press the [BRILL ] key for a short period of time to display the menu ([Panel brill]).
2
Rotate the [GAIN (HF) Knob] or [GAIN (LF)
Knob]. When “1” is selected, it is darkest.
When “10” is selected, it is brightest.
Panel brill
10
3
Press the [MENU] key to close the menu.
1.4 Switch-over of Display mode
7 kinds of displays are provided in all. Select the display suitable for your purpose.
1
Press the [DISP] key.
2
Select the display you desire to display.
(Press the [ ] key or [ ] key.)
(The set item can be selected by rotating the
[GAIN (HF) Knob] or [GAIN (LF) Knob].)
Disp
NAV1
Normal (H)
Zoom (H)
Dual Freq
Zoom (L)
Normal (L)
NAV2
(H): High frequency
(L): Low frequency
NAV1: Navigation display1
NAV2: Navigation display2
3
Press the [MENU] key to close the menu.
Normal Image (Low frequency, High frequency)
Low frequency
Since the beam width is wide, the search range becomes wide so that the beam can search the deep depth.
High frequency
Since the beam width is narrow, it is hard to be interfered by noise and bubble in the sea so that the schools of fish can be searched in a high resolution.
Low frequency
(50 kHz)
High frequency
(200 kHz)
CVS-128/128B Chapter 1 Basic Operation
Dual frequency
The High frequency image can be displayed in the right half side and the Low frequency image can be displayed in the left half side. Since the beam width differs depending on frequency, the schools of fish and sea bottom look different.
Caution: The low frequency screen can be displayed in the right half of the sceen by replacing the screen and the high frequency screen is displayed in the left harf. (See [2.17 Explanation of Menu
Item, Image Swap])
Low frequency image
High frequency image
Zoom (Low frequency, High frequency)
The normal image is displayed in the right half of the screen and the zoom image is displayed in the left half. A part of normal image can be zoomed. (1) [BTM.] (Bottom), (2) [B.D.] (Bottom Discrimination), (3)
[Zoom], (4) [B.Z.] (Bottom Zoom) and (5) [B.F.Z.] (Bottom Follow Zoom) are provided for zoom.
The unit is set to (1) [BTM.] at ex-factory. To change to other zoom display, set it in the menu. (See [2.7
Selection of Zoom])
Caution: A right and left display can be switched. (See [2.17 Explanation of Menu Item, Image
Swap])
Zoom type
Bottom
Purpose
It is convenient to see the schools of fish near the bottom.
Zoom start position
It displays the position of the bottom in the fixation in the display bottom part.
Zoomed range
It displays the bottom and upper in the zoom.
Bottom
Discrimination
Zoom
It is convenient to see the schools of fish and a bottom quality near the bottom.
It is convenient to see the specified range in the zoom.
It displays the position of the bottom in the fixation in the position of 1/4 under the display.
It displays a zoom start position in the fixation at the top of the display.
It displays the bottom and upper in the zoom, it displays under the bottom in the ordinary.
(Under the bottom, it doesn't display in the zoom).
It displays in the zoom from the zoom start position to the range you set.
Bottom Zoom
Bottom Follow
Zoom
It is convenient to see the schools of fish near the bottom and the form of the bottom.
It is convenient to see the schools of fish near the bottom and the form of the bottom.
It displays the position of the bottom in the position which is the same as the ordinary display.
It always displays the position of the bottom in the lower part of the display.
It displays upper side of the bottom in the zoom except the bottom.
It displays the bottom and upper and lower sides in the zoom.
0093112802-06 1-5
Chapter 1 Basic Operation
(1) Bottom
Zoomed range
(2) Bottom Discrimination
Zoomed range
(3) Zoom
Zoom start position
Zoomed range
The display width of zoom is displayed in orange.
Normal image
30.0
Zoom image
The display width of zoom
is displayed in orange.
Normal image
30.0
Zoom image
The display width of zoom is displayed in orange.
Normal image
CVS-128/128B
30.0
Zoom image
CVS-128/128B
(4) Bottom Zoom
Chapter 1 Basic Operation
The display width of zoom is displayed in orange.
Normal image
Zoomed range
(5) Bottom Follow Zoom
Zoomed range
30.0
Zoom image
The image below the bottom is not zoomed.
The display width of zoom is displayed in orange.
Normal image
30.0
Zoom image
Navigation Menu (NAV1, NAV2)
The navigation menu can be displayed on the left side of the display. To display the information other than depth, sensors need to be connected. (See [1.5 Selection of NAV Display])
Caution: Requires position data from GPS sensor.
Depth
Water temp
Course
XTE
0093112802-06 1-7
Chapter 1 Basic Operation CVS-128/128B
1.5 Selection of NAV Display
Selection of NAV Display
The information can be displayed on the NAV display (NAV 1, NAV2).
Caution:Requires position data from GPS sensor.
Type of NAV Display
The following images can be displayed on the
NAV Display (NAV1, NAV2).
Simple plotter Compass
Depth
Speed meter
Speed meter
HDG
XTE
The time required
Wind dir.
Wind speed
Lat/Lon
Boat speed
Course
RNG BRG
Water temperature
Heading, XTE, Time required, Wind dir., Wind speed, Depth, Lat/Lon,
Boat speed, Course,
RNG BRG, Water temp
Selection of NAV Menu
1
Press the [DISP] key.
2
Select the [NAV1] or the [NAV2]. (Press the
[ ] key or [ ] key)
3
[NAV1] is displayed at the right side.
Disp
NAV1
Normal (H)
Zoom (H)
Dual freq
Zoom (L)
Normal (L)
NAV2
NAV1
Display1
Display2
Display3
Display4
4
Press the [ ] key.
5
Select either one of [Display1] to [Display4] by operating [▲] or [▼] key. At the locations where Display of NAV is shown, a numerical figure 1 , 2 , 3 or 4 is indicated. (The figure below is the case where [Display 1] is selected).
Depth
NAV1
Display1
Display2
Display3
Display4
Caution: When simple plotter, speed meter or compass is displayed on the screen,
[Display2] and [Display4] cannot be selected.
6
Press the [ ] key.
7
Select the [Display1]. (Press the [ ] key or
[ ] key.)
Display1
Simple plotter
Compass
Speed meter
Depth
Lat/Lon
Boat speed
Course
8
Press the [MENU] key to close the menu.
CVS-128/128B Chapter 1 Basic Operation
1.6 Switch-over of Range
The range of measured depth displayed on the display can be changed.
To meet your purpose, select the range of measured depth.
Setting the range switching to auto range
By following automatically the bottom, the image of echo sounder in the suitable range of measured depth can be displayed.
This mode is convenient to display always the range from sea level to bottom.
The range value
changes
1
Press [▲] or [▼] key of [▲RANGE▼].
2
Select the [Auto Range]. (Press [▲] or [▼] key of [▲RANGE▼])
Range
Auto range
5.0
10.0
20.0
50.0
100
160
300
500
Auto shift
3
Press [MENU] to close the menu.
When [Auto Range] is set, the [R:A] is displayed at the upper side of menu.
Caution: At auto range, this sounder can sound the area up to the maximum sounding registered. The maximum range is 800 m. At the initial setup, the range is up to 200 m for CVS-128 and up to 500 m for CVS-128B. (See [3.6
Setting of Adujust2 Item, Sounding])
Setting the range switching to Manual range
The range can be manually selected:
1
Press [▲] or [▼] key of [▲RANGE▼].
2
Select the range you desire to set. (Press
[▲] or [▼] key of [▲RANGE▼])
Range
Auto range
5.0
10.0
20.0
50.0
100
160
300
500
Auto shift
3
Press the [MENU] key to close the menu.
When the [Manual] is set, the [R: M] is displayed at the upper side of menu.
1.7 Setting of Shift
The [Shift] (Manual Shift) and [Auto Shift] are provided.
Manual Shift (Shift):
The image range is shifted up and down.
(Setting: m, fm, I.fm: 0 ~ 300, ft: 0 ~ 1000)
Caution: Only when the [shift] is registered in [F1] key or [F2] key, it is effective. It is invalid when not registered. (See [1.10 Use of [F1] / [F2] key)
Caution: When the equipment is shipped from the factory, the [shift] is registered in the [F2] key.
Auto Shift:
The image is automatically shifted so that the bottom is always displayed.
Setting of Manual Shift
The scope of range starting with the shift value is displayed.
0093112802-06 1-9
Chapter 1 Basic Operation CVS-128/128B
1
Press [F2] key twice. The shift function is turned on.
Shift
OFF
ON
2
Press the [MENU] key to close the menu.
3
Press the [ ] key or [ ] key.
4
Change the set value of [Shift]. (Press the
[ ] key or [ ] key)
Shift
0~300
10 m
5
Press the [MENU] key to close the menu.
Caution: This operation cannot be done while an auto range or auto shift is working.
Release of manual Shift
The shift function is released, and it returns it to former screen.
1
Press twice the [F2] key. The shift function is turned off.
Shift
OFF
ON
2
Press the [MENU] key to close the menu.
Setting of Auto Shift
The image is automatically shifted so that the bottom is always displayed.
1
Press [▲] of [▼] key of [▲RANGE▼].
2
Select the [Auto shift] (Press [▲] of [▼] key of [▲RANGE▼])
Range
Auto range
5.0
10.0
20.0
50.0
100
160
300
500
Auto shift
Range
40.0
3
Press the [ ] key.
Range
Auto range
5.0
10.0
20.0
50.0
100
160
300
500
Auto shift
Range
40.0
4
Select a range at [Auto shift]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
When the [Auto shift] is set, the [R : AS] is displayed at the upper side of menu.
1.8 Gain Adjustment
The gain can be adjusted in the auto mode
[Cruising, Fishing] or manual mode.
[Cruising]
Eliminating the weak echo, it displays clearly the sea bottom of strong echo.
It is suitable for cruising to the fishery ground.
[Fishing]
It displays clearly the weak echo reflected from the school of fish.
It is suitable for searching the schools of fish.
CVS-128/128B
Basic Operation of Gain
When [GAIN (HF) Knob] or [GAIN (LF) Knob] is pressed twice, the screen of [Gain select] is displayed.
By rotating the [GAIN (HF) Knob] or [GAIN (LF)
Knob], the gain adjustment or auto gain can be selected.
Caution: The high frequency can be set by
[GAIN (HF) Knob] and the low frequency can be set by [GAIN (LF)
Knob].
Caution: When only high frequency is displayed, no gain adjustment at low frequency is available. When only low frequency is displayed, no gain adjustment at high frequency is available.
Selecting the auto gain
When the [Cruising] or [Fishing] is set, the gain can be fine-adjusted.
1
Press [GAIN (HF) Knob] twice, and [Gain select] is displayed. (The high frequency is explained below.)
Caution: The low frequency can be set by
[GAIN (LF) Knob].
2
Select the [Cruising] or [Fishing] by rotating the [Knob].
Gain select
Manual
Cruising
Fishing
3
Press the [MENU] key to close the menu.
When the [Cruising] is set, the [L: AC] [H:
AC] is displayed at the upper side of menu.
When the [Fishing] is set, the [L: AF] [H: AF] is displayed at the upper side of menu.
Adjusting the gain by auto
The auto gain adjustment can be set to [Auto adjust high] or [Auto adjust low]. (Setting:-30 ~
10)
1
Turn [GAIN (HF) Knob], and [Auto adjust high] is displayed. (The high frequency is explained below.)
Chapter 1 Basic Operation
Caution: The low frequency can be set by
[GAIN (LF) Knob].
2
Fine-adjust the gain by rotating the [GAIN
(HF) Knob]. The [Cursor] key menu position can be moved.
Auto adjust high
0
3
Every time when [GAIN (HF) Knob] is pressed, the [Gain select] and [Auto adjust high] are alternately displayed.
4
Press the [MENU] key to close the menu.
Selecting the manual gain
Adjustment of gain can be done manually.
1
Press [GAIN (HF) Knob] twice, and [Gain select] is displayed. (The high frequency is explaied below.)
Caution: The low frequency can be set by
[GAIN (LF) Knob].
2
Select the [Manual] by rotating the [Knob].
3
Press the [MENU] key to close the menu.
Manual adjustment of the gain
When only the image of High frequency is displayed, the High frequency gain can be adjusted. (Setting: 0 to 10)
When only the image of Low frequency is displayed, the Low frequency gain can be adjusted.
Caution: If you increase the gain too much, noise will appear on the entire image, resulting in an unclear image. Adjust properly the gain so that the optimum image can be always displayed.
Over-gain Optimum Under-gain
1
Turn [GAIN (HF) Knob] to display [Auto adjust high]. (The high frequency is explained below.)
0093112802-06 1-11
Chapter 1 Basic Operation
Caution: The low frequency can be done by [GAIN (LF) Knob].
2
Adjust the gain by rotating the [Knob]. The
[Cursor] key menu position can be moved.
Gain(H)
6.0
Stop increasing of the gain just before noise appears on the image.
3
Every time when [GAIN (HF) Knob] is pressed, the [Gain select] and [Gain (H)] are alternately displayed.
4
Press the [MENU] to close the menu.
The latest set value of frequency (High frequency or Low frequency) adjusted is displayed at the upper left side of menu.
Example:
The High frequency gain is 8.0
H: 8.0.
H: 8.0
R: M 12.6 V
1.9 Use of [EVENT] key
By pressing the [EVENT] key, three functions of
[Store Position]. [Store Image] and [Fishing hot spot] are available.
The fishing hot spot is the function to instruct your boat to navigate easily to a point where you desire to go back.
[Store pos]: The latitude and longitude of a point can be stored in the destination list.
[Store image]: An image of the echo sounder can be stored in the internal memory.
[Fishing hot spot]: The WPT navigation starts, using the latitude and longitude of a point which is set as a destination by pressing the [EVENT] key. Simultaneously, the latitude and longitude of the point can be stored in the destination list.
Caution: Requires position data from GPS sensor.
Selecting the event key function
Select the functions when pressing the [EVENT] key.
1
Press the [MENU] key.
2
Select [System]
[EVENT Key set]. (Press the [ ] key or [ ] key or [ ] key) (See [2.1
L H
CVS-128/128B
How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [EVENT key set].
(Press the [ ] key or [ ] key)
EVENT key set
Store pos
Store image
Fishing hot spot
5
Press the [MENU] to close the menu.
Presetting the waypoint
When you find the school of fish or tide, its location can be preset as a waypoint.
(10 locations at maximum)
When presetting the waypoint, switch [System]
[EVENT Key set] [Store pos]. (See [1.9 Use of [EVENT] key Selecting the event key function])
1
In the state that no other key is pressed, press the [ ] key or [ ] key.
2
Move the cursor (red line) with the [ ] key or
[ ] key to the location to be preset as a waypoint.
Cursor (Red line)
3
Press the [EVENT] key.
When decided, the red line is drawn at the designated location on the echo sounder menu and the latitude and longitude of designated location are registered in the waypoint list.
At this moment, the list number of preset waypoint is displayed.
CVS-128/128B Chapter 1 Basic Operation
L
L
H
H
Cursor
(Red line)
Waypoint list # 1 is registered
4
After a certain time passes, the message disappears and presetting the waypoint is finished.
Caution: When pressing the [EVENT] key, if [In out]
[NMEA output data]
[TLL] is set to ON, the latitude and longitude of location above-designated is output to the navigation system connected.
Caution: If the waypoint list is full, the preset destination list is not deleted, showing the message that the list is fully filled.
After a certain time passes, the message disappears.
A waypoint list is full.
Registration is not completed
Caution: If the waypoint list is full, delete an unnecessary waypoint from the waypoint list.
Store the image
When you find the schools of fish, its location can be stored as a waypoint.
(10 locations at maximum)
When storing the image, switch [NAV]
[EVENT Key set]
[Store pos]. (See [1.9 Use of
[EVENT] key Selecting the event key function].)
1
Press the [EVENT] key.
Processing
is displayed.
2
After a certain time passes, the image of echo sounder presently displayed is stored and the list number of stored image is displayed.
Image data list # 1 is registered
3
After a certain time passes, the message disappears and storing the image is finished.
Caution: If the waypoint
list is fully filled, the preset destination list is not deleted, showing the message that the image is fully filled. After a certain time passes, the message disappears.
A list of Pic is full.
Registration is not completed.
As for deletion and recall of images, see
[2.15 Store/Recall/Deletion of image].
Fishing hot spot
Leads you back to your favorite fishing hot spots or other previously stored positions in memory with input from optional GPS sensor. (See [2.14
Preset/ WPT edit/ WPT delete of Waypoint])
To perform the fishing hot spot, it is necessary to select [System]
[EVENT key set] [Fishing hot spot]. (See [1.9 Use of [EVENT] key
Selecting the event key function].)
1
In the state that no other key is pressed, press the [ ] key or the [ ] key.
2
Move the cursor (red line) to a point you desire to go back with the [ ] key or [ ] key.
0093112802-06 1-13
Chapter 1 Basic Operation CVS-128/128B
L H
Cursor (Red line)
3
Press the [EVENT] key.
When you decide, the red line is drawn on the image of the echo sounder at the point you designate and the latitude and longitude of the point you designate is stored in the destination list.
At this moment, the number of the stored destination list is displayed.
4
The navigation display (NAV1) is displayed and the WPT navigation starts.
Lat/Lon
Note: The display of NAV1 is displayed.
5
To stop the fishing hot spot, cancel destination navigation. (See: [2.14 Preset/
WPT edit/ WPT delete of Waypoint], [Cancel the NAV].)
1.10 Use of [F1] / [F2] key
At ex-factory, the [Image Speed] is assigned to the [F1] key, and the [Shift] is assigned to the
[F2] key. The function settable to the [F1]/[F2] key can be selected among [Image Speed], [IR],
[Color Rejection], [Noise Rejection], [Shift],
[Zoom Range], [Zoom Start], [A scope], [White line], [Background color], [Disp width], [Nav start],
[NAV1], [NAV2], [Image swap], [Image recall] and
[Sona-tone]. Set the function frequently used for your convenience.
Selecting the [F1]/[F2] key
1
Press the [F1] key or [F2] key.
2
Select the setting with [ ] key or [ ] key.
Example [Image speed]
Image speed
Speed1
Speed2
Speed3
Speed4
Stop
Speed5 (1/1)
Speed6
Speed7
Speed8
Speed9
Caution: When the fish symbol function is made effective, the image speed becomes two kinds ([Speed5 (1/1)] or
[Stop]).
3
Press the [MENU] key to close the menu.
Preset of [F1] / [F2] key
1
Press the [MENU] key.
2
Select [System]
[F1 key set] or [F2 key set]. (Press the [ ] key or [ ] key or [ ] key.) (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the function. (Press the [ ] key or [ ] key)
CVS-128/128B
F1 key set
Image Speed
IR
Color Rejection
Noise Rejection
Shift
Zoom Range
Zoom Start
A scope
White line
Background Color
5
Press the [MENU] key to close the menu.
The icons of functions preset are displayed at the upper right side on the menu.
←
←
←
←
←
←
←
←
←
←
Image speed
IR
Color rejection
Noise rejection
Shift
Zoom Range
Zoom Start
A scope
White Line
Background color
←
←
Image recall
Image swap
←
NAV1
←
NAV2
←
Disp width
← Sona-tone
Other than the above operation method. When keep pressing the [F1] key or [F2] key for few second, the key set menu is displayed.
1.11 Operation of VRM
The VRM (movable marker) shown by the green line can be moved up and down.
It is convenient to measure the depth by aligning with the target such as school of fish.
1
Press the [ ] key or [ ] key. The movable marker (straight line) is displayed.
2
Press the [ ] key or [ ] key. The movable marker moves up and down.
The movable marker and the numerical of marker depth are simultaneously highlighted.
L
Chapter 1 Basic Operation
H
20.0
Marker Depth
Movable marker
When displaying dual images, if the [ ] key or [ ] key is pressed, the movable marker moves to the neighboring image.
Caution: When several seconds pass after finishing the VRM operation, the numerical of marker depth becomes normal display.
Caution: If VRM is moved to the top of the display, the VRM can be disappeared.
Caution: VRM can be operated by turning
[GAIN (LF) Knob] at the high frequency screen.
Caution: VRM can be operated by turning
[GAIN (HF) Knob] at the low frequency screen.
1.12 Display of fish information
When transducer TD-501C is connected, specific response can be displayed as [Fish symbol].
For detection of fish information, 2 frequencies,
200 kHz and 50 kHz are used.
Only in case echo comes up in both frequencies, the detection can be made.
By [Symbol info], the magnitude and the value of depth of the response can be displayed.
Caution: Fish information is to display the specific responses in an easy way to watch. Displays of [Fish symbol] do not always mean that there is fish there.
0093112802-06 1-15
Chapter 1 Basic Operation
Caution: The area where [Fish symbol] can be displayed is from 3 m to 100 m.
(ft: 10 to 330, fm: 2 to 54, I.fm:2 to 60)
Caution: [Fish symbol] is not displayed in the range that is deeper than 120m. (ft:
350, fm:60, I.fm:70)
Caution: When the fish symbol function is made effective, the image speed becomes 2 kinds ([Speed5 (1/1)] or
[Stop]).
Caution: Adjustment is necessary when equipped with Inner-hull. (See [2.17
Explanation of Menu Item, Inner-hull].)
Display the fish symbol/Stop the display of fish symbol
1
Press the [MENU] key.
2
Select [Display1]
[Fish symbol]. (Press the [ ] key or [ ] key or [ ] key.) (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the symbol to be displayed on the screen. (Press the [ ] key or [ ] key)
Fish symbol
Symbol 1
5
Press the [MENU] key to close the menu.
When this function is effective, the icon is displayed at the top of the screen.
Caution: When [Fish symbol] on the screen does not always mean that the response shows fish.
Selecting the symbol info
[Symbol info] is effective only when [Fish symbol] is displayed.
1
Press the [MENU] key.
2
Select [Display1]
[Symbol info]. (Press the [ ] key or [ ] key or [ ] key.) (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the information associated with [Fish symbol] (Press the [ ] key or [ ] key.)
CVS-128/128B
Symbol info
OFF
Depth
Size
Bottom<=>Fish
Caution: The display of [Size] is expressed in cm.
5
Press the [MENU] key to close the menu.
Caution: The magnitude by [Symbol info] would not be always the response from fish. And it may be incorrect due to various environmental conditions.
Please take these as reference.
Caution: The value of depth by [Symbol info] would not be always the response from fish. That shows the point that there was specific response.
Fish symbol detection adjustment
Detection of fish marks can be adjusted.
Select [Correct]
[Detect adjust f].
Caution: If the larger the set values become, the more fish marks can be displayed with more false detections.
Caution: For Through-hull installation, adjust between 1 and 4. For
Inner-hull installations, adjust between 3 and 6.
Size adjustment
The indicated size of fish marks can be adjusted.
Please correct the size when the indicated value is different from the fish that actually caught.
Select [Correct]
[Size adjust].
The indicated size will change by approximately
10 to 20 percent of the value, per one setting value.
CVS-128/128B
Caution: When the value of [Detect adjust f] is set at 5 or 6, the size of fish can not be specified and there may be cases where no numerical figures are displayed or only "----" is displayed. When there is no display of numerical figures, it is judged that fish are too small. When "---" is displayed, it is judged that fish is too big.
Big fish / Big fish color
The fish bigger than the set value [cm] is specified as big fish.
Select keys of [Display2]
[Big fish].
Colors for values of big fish can be assigned.
Select keys of [Display2]
[Color table 2]
[Big fish color].
Chapter 1 Basic Operation
Points to note in use of fish symbol
The values displayed by this function may be incorrect depending on various environmental conditions. In use of these values, please understand the following factors of error, and use them as reference:
[Factors of error]
1
When there are overlapping responses, all of them may be displayed to show the magnitude of a point.
2
The strength of reflection may depend on the output of transducer unit and may result in a factor of error.
3
The strength of reflection may depend on the kind of fish and may result in a factor of error. As for the fish such as the squid which don't have an air bladder, the error is big.
4
Fish banks, fishing net, fishing equipment, air bubbles and floating objects, etc. may be detected and displayed.
5
When the transducer unit is mounted in inner-hull, there may be cases where response cannot be detected depending on attenuation, and large error may be generated.
6
The strength of reflection may depend on the difference of ship handling such as stoppage and cruising, and may result in a factor of error.
7
Each transducer unit may have difference in transmission/receiving performance to cause error.
8
When there is dirt in the sea and the plankton layers have been generated, it becomes the factor of the error margin.
0093112802-06 1-17
CVS-128/128B Chapter 2 How to use the menu
Chapter 2 How to use the menu
2.1 How to operate the menu
Display the menu/Stop the display of menu
1
Press the [MENU] key.
The menu and explanation of operation are displayed.
Name of menu selected
Menu column
Cursor
Setting item column
Setting value
Adjust
D.range
Display1
Display2
Alarm1
Alarm2
NAV
Image
System
Freq*
Next
Image speed
IR
Color rejection
Noise rejection
TVG
TX power
Gain (TD)
Pulse width*
Band width*
D.Range*
Return
* For CVS-128B
Guide
Speed 5
Strong
0%
0
Medium
Auto
Middle
Middle
24dB
It is displayed when the [Operation Guide] is set to ON.
(See [2.17 Explanation of Menu Item Display the operation guide / Stop the display of operation guide].)
2
Press the [MENU] key.
The menu and explanation of operation close.
Menu Operation
1
When the menu is displayed, press the [ ] key or [ ] key to select the menu name.
Depending on the selected menu name, the content in the set item column at the right side changes. (The menu name can be selected by rotating the [GAIN (HF)
Knob] or [GAIN (LF) Knob].)
Adjust
D.range
Display1
Display2
Alarm1
Alarm2
NAV
Image
System
Freq*
Next
* For CVS-128B
Shift step
Zoom type
Zoom range
Zoom start
Disp width
Range preset
Return
2
Press the [ ] key.
The cursor appears in the set item column.
(The cursor appears by pressing the [GAIN
(HF) Knob] or [GAIN (LF) Knob].)
3
Select the set item you desire to change with the [ ] key or [ ] key.
(The set item can be selected by rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob])
Adjust
D.range
Display1
Shift step
Zoom type
Display2
Alarm1
Alarm2
NAV
Image
System
Freq*
Next
Zoom range
Zoom start
Disp width
Range preset
Return
* For CVS-128B
1m
Bottom
10.0m
0m
Center
4
Press the [ ] key.
The set menu corresponding to the selected item is displayed.
(It can be displayed by rotating the [GAIN
(HF) Knob] or [GAIN (LF) Knob].)
Zoom range
10.0
m
1m
Bottom
10.0m
0m
Center
5
Change the set content with the [ ] key or
[ ] key.
(It can be changed by rotating the [Knob])
6
Press the [ ] key.
The cursor returns to the set item column.
0093112802-06 2-1
Chapter 2 How to use the menu
(It can be displayed by rotating the [GAIN
(HF) Knob] or [GAIN (LF) Knob])
7
To select the other menu item, press the
[ ] key.
The cursor returns to the menu column.
8
Press the [MENU] key to close the menu.
2.2 Changing of Image Speed
The image speed of echo sounder can be changed. Even if the schools of fish and bottom are same, the image changes depending on the image speed.
The image speed becomes slow in the order of
[Speed1]
[Speed2]····· [Speed9].
When [stop] is selected, the image stops.
Caution: When the fish symbol function is made effective, the image speed becomes 2 kinds ([Speed5 (1/1)] or
[Stop]).
1
Press the [MENU] key.
2
Select the [Adjust]
[Image Speed]. (See
[2.1 How to operate the menu].)
3
Press the [ ] key.
4
Change the setting of [Image Speed].
(Press the [ ] key or [ ] key.)
Image speed
Speed 1
Speed 2
Speed 3
Speed 4
Stop
Speed 5 (1/1)
Speed 6
Speed 7
Speed 8
Speed 9
5
Press the [MENU] key to close the menu.
2.3 Rejection of Interference
Interference Rejection
The interference noise from the echo sounder of other boats can be reduced.
If a neighboring boat uses the echo sounder having the same frequency and pulse transmission rate as those your boat has, the interference noise may be displayed. If you set the interference rejection, the interference noise can be reduced. In the order of weak
strong, the noise rejection capability becomes high.
The difference of images based on the different settings of [Intererence reduction]
Image of school of fish
Interference image
CVS-128/128B
OFF
Weak
Strong
1
Press the [MENU] key.
2
Select the [Adjust]
[Interference Rejection].
(See [2.1 How to operate the menu].)
3
Press the [ ] key.
4
Change the setting of [Inference Rejection].
(Press the [ ] key or [ ] key.)
IR
OFF
Weak
Strong
5
Press the [MENU] key to close the menu.
2.4 Color Rejection of Weak
Echo
Color Rejection
The color of weak echo can be rejected.
Rejecting noise on the entire image and weak echo around the school of fish makes it easier to see the school of fish. It is the convenient function when displaying the echo stronger than the specific signal. (Setting: 0 to 50 %)
1
Press the [MENU] key.
2
Select the [Adjust]
[Color Rejection].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [Color Rejection].
(Press the [ ] key or [ ] key.)
Color Rejection
0
%
5
Press the [MENU] key to close the menu.
2.5 Rejection of Noise
Noise Rejection
The influence of noise can be reduced.
Due to echo reflected from plankton and trash, the speck-like noise may appear on the entire image. Setting the [Noise rejection] reduces the speck-like noise and makes it easier to see the image of school of fish. (Setting: 0 to 10)
The greater the set value becomes, the stronger the effect of noise rejection becomes.
1
Press the [MENU] key.
2
Select [Adjust]
[Noise rejection]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [Noise rejection].
(Press the [ ] key or [ ] key)
Noise Rejection
5
5
Press the [MENU] key to close the menu.
2.6 Setting of Shift step
The shifting range is set by pressing the [ ] key or [ ] key one time. (Setting range: 1m,
10m, 1/8, 1/4)
1
Press the [MENU] key.
2
Select the [D.range]
[Shift step]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [Shift step]. (Press the [ ] key or [ ] key.)
Shift step
1m
10m
1/8
1/4
5
Press the [MENU] key to close the menu.
Caution: When the shift is set to 1/4 with 100m range, it shifts by 25m.
2.7 Selection of Zoom
Set the zoom display with the display mode
([zoom (H)] or [zoom (L)].
The [Bottom], [Bottom Discrimination], [Zoom],
[[Bottom Zoom] and [Bottom Follow Zoom] are provided. (See [1.4 Switch-over of Menu])
1
Press the [MENU] key.
2
Select [D.range]
[Zoom type]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the zoom type. (Press the [ ] key or
[ ] key)
0093112802-06 2-3
Chapter 2 How to use the menu CVS-128/128B
Zoom type
BTM.
B.D.
Zoom
B.Z.
B.F.Z.
5
Press the [MENU] key to close the menu.
For each zoom display, refer to [1.4 Switch-over of Display mode].
2.8 Setting of Zoom Range
Set the zoom range in each mode of [BTM],
[Bottom Discrimination], [Zoom], [Bottom Zoom] and [Bottom Follow Zoom]
The zoom range of each mode is identical.
(See [1.4 Switch-over of Display mode])
(Setting: m: 2.5 to 200, fm, I.fm: 2.5 to 150, ft:10.0 to 650)
2.9 Setting of Zoom Start
Select the zoom start in the [Zoom].
(See [1.4 Switch - over of Display mode])
(Setting: m: 0 to 800, fm, I.fm: 0 to 500, ft: 0 to
2600)
Zoom Start
Zoom Range
1
Press the [MENU] key.
2
Select [D. range]
[Zoom range]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Change the set value of [Zoom range].
(Press the [ ] key or [ ] key)
Zoom Range
10.0
m
5
Press the [MENU] key to close the menu.
1
Press the [MENU] key
2
Select [D. range]
[Zoom start] (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Change the set value of [Zoom start].
(Press the [ ] key or [ ] key)
Zoom start
10 m
5
Press the [MENU] to close the menu.
2.10 Preset of Range
The range switched with the [ RANGE ] key can be set.
Preset the set value suitable for your purpose.
(Setting range: m: 2.5 to 1200, fm, I.fm: 2.5 to
700, ft: 10 to 3600)
1
Press the [MENU] key.
2
Select [D.range]
[Range preset]
[Range 1 to 8]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select [Range 1 to 8]. (Press the [ ] key or
[ ] key)
Adjust
D.range
Disp1
Prev
Range 1
Disp2
Alarm1
Alarm2
NAV
Range 2
Range 3
Range 4
Image
System
Freq*
Next
Range 5
Range 6
Range 7
Range 8
Return
* For CVS-128B
5.0 m
10.0 m
20.0 m
50.0 m
100 m
160 m
300 m
500 m
Caution: Select [Forward], and press [ ] key to return to the previous menu.
5
Press the [ ] key.
6
Select the set value of [Range 1 to 8].
(Press the [ ] key or [ ] key)
Range1
20.0
m
7
Press the [MENU] key to close the menu.
Easy registration method of the range
1
Press [▲] or [▼] key of [▲RANGE▼].
2
Change the range you desire to set. (Press
[▲] or [▼] key of [▲RANGE▼])
Range
Auto range
5.0
10.0
20.0
50.0
100
160
300
500
Auto shift
3
Press the [ ] key.
4
Select the set value of Range. (Press the
[ ] key or [ ] key)
Range1
5.0
m
5
When the [ ] key is pressed, it returns to the [range]. Other detecting range can be continuously changed.
6
Press the [MENU] key to close the menu.
2.11 Setting of Background
Color
Responding to the ambient brightness, the background color of display can be changed.
1
Press the [MENU] key.
2
Select [Display1]
[Background color].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [Background color].
(Press the [ ] key or [ ] key)
Background color
Pale blue
Marine blue
Blue
Dark blue
Black
Darkkhaki
Mediumseagreen
Light grey
White
Night mode
5
Press the [MENU] to close the menu.
2.12 Setting of White Line
As the surface of bottom is marked with the white line of constant width, the school of fish at the bottom can be easily identified.
0093112802-06 2-5
Chapter 2 How to use the menu CVS-128/128B
White line
1
Press the [MENU] key
2
Select [Display1]
[White line]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [White line].
“1” is narrowest. “5” is widest.
In the auto mode, responding to the strength of echo reflected from the bottom, the width of white line changes. (Press the
[ ] key or [ ] key)
White line
2
3
OFF
1
4
5
Auto
5
Press the [MENU] key to close the menu.
2.13 Setting of Alarm
6 alarms of bottom alarm, fish alarm, water temp alarm, speed alarm, arrival alarm and XTE alarm can be set.
They are notified by alarm sound and alarm display.
[Bottom alarm] issues the alarm when the position recognized as the bottom is shallower than the upper limit or deeper than the lower limit. It is convenient when keeping the specific depth. (Setting: m: 0 to 800, fm, I.fm: 0 to 700, ft: 0 to 2800)
[Fish alarm] issues the alarm when an echo recognized as school of fish exists in the set range. It is convenient for you to judge whether the echo of school of fish is present or not.
(Setting: m: 1 to 800, fm, I.fm: 1 to 700, ft: 1 to
2800)
Caution: In the [Level], select the strength of echo reflected from the schools of fish in the [Fish alarm].
[Water temp alarm] issues when the water temp is within or out of the set range. It is convenient to keep the specific water temp region. (Setting:
- 5 to 45 ºC, 23 to 113 ºF)
[Speed alarm] issues when the boat speed is faster or slower than the set range. It is convenient when the speed limit is obliged.
(Setting: 0 to 80 kn, 0 to 148 km/h)
[Arrival alarm] can be used in the state that the destination is set. The alarm is issued when your boat arrives within a certain range of destination.
A certain range is set in the [NAV alarm range].
(See [1.9 Use of [EVENT] key.)
[XTE alarm] can be used in the state that the destination is set. The alarm is issued when your boat is off a certain distance from the course on the line drawn straightly from destination to the location when setting the destination. A certain distance is set in the [NAV alarm range].
Caution: In the [NAV alarm range], select the alarm range of [Arrival alarm] and [XTE alarm]. (Setting: 5 to 999 m)
Caution: The setting range of [Arrival alarm] and [XTE alarm] can not be separately set.
Stopping the alarm sound
To stop the alarm sound and the alarm display, press [MENU] key.
Setting the alarm
Adjust
D.range
Disp1
Disp2
Alarm1
Alarm2
NAV
Image
System
Freq*
Next
Bottom alarm
Upper depth
Lower depth
Fish alarm
Position
Range
Level
Return
OFF
5m
50m
OFF
5m
50m
Medium
Adjust
D.range
Disp1
Disp2
Alarm1
Alarm2
NAV
Image
System
Freq*
Next
* For CVS-128B
Water temp alarm
Upper temp alarm
Lower temp alarm
Speed alarm
Speed limit
Arrival alarm
XTE alarm
NAV alarm range
Return
OFF
20.0ºC
15.0ºC
OFF
0kn
OFF
OFF
10m
1
Press the [MENU] key.
2
Select your desired alarm from [Alarm 1] or
[Alarm 2]. (See [2.1 How to operate the menu].)
3
Press the [ ] key.
4
Select the [ON] of alarm you desire. (Press the [ ] key or [ ] key)
5
If the setting of [Alarm range] is provided in the alarm desired, select the alarm range.
(See [2.1 How to operate the menu])
6
Change the set value of alarm range.
(Press the [ ] key or [ ] key)
7
Press the [MENU] key to close the menu.
Release the alarm
1
Press the [MENU] key.
2
Select the alarm to be released from
[Alarm 1] or [Alarm 2]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [OFF] of alarm to be released.
(Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Confirm the alarm state
The set state of [Bottom alarm] and [Fish alarm] can be confirmed on the bar at the right corner of display. However, when the display is out of the range, they are not displayed.
When [Water temp alarm], [Speed alarm],
[Arrival alarm] or [EXT alarm] is ON, the corresponding icon is displayed at the upper side of the screen.
[ XTE alarm]
[ Arrival alarm]
[ Speed alarm
]
[
Water temp alarm
]
[Bottom alarm
]
[
Fish alarm
]
0093112802-06 2-7
Chapter 2 How to use the menu
2.14 Preset/WPT edit/WPT delete of Waypoint
NAV Start
The NAV can be started by selecting the destination from the destination list.
To perform the NAV start, the destination must be preset. (See [1.9 Use of [EVENT] key]
)
Caution: Requires position data from
GPS sensor.
1
Press the [MENU] key.
2
Select [NAV]
[NAV start]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Destination list] preset. (Press the [ ] key or [ ] key)
Caution: The list No. selected is reversed in yellow.
5
Press the [ ] key.
6
Select the [Yes] in the confirmation menu.
(Press the [ ] key or [ ] key)
NAV starts
Yes
No
7
Press the [MENU] key.
Then, the NAV starts.
CVS-128/128B
Cancel the NAV
The NAV started can be cancelled halfway.
1
Press the[MENU] key
2
Select [NAV]
[NAV cancel]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Press the [Yes]. (Press the [ ] key or [ ] key)
NAV cancel
Yes
No
5
Press the [MENU] key. Then, the NAV is released.
6
To return the display to the original one, the display mode shall be switched over.
(See: [1.4 Switch-over of Display mode])
Edit the destination
By entering the latitude and longitude, the destination can be preset.
The list preset in the past can be edit.
1
Press the [MENU] key.
2
Select [NAV]
[WPT edit]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the list No. to be edited from the
[WPT edit] list. (Press the [ ] key or [ ] key)
5
Press the [ ] key.
6
Select the character with the [ ] key or [ ]
key. (Character: A ~ Z, blank, 0 ~ 9, +, -./
Lat/Lon: 0~9,N,S,E,W)
Delete the waypoint
The destination list preset in the past can be deleted.
The deletion takes some time.
1
Press the [MENU] key.
2
Select [NAV]
[WPT delete]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the list number of destination to be deleted from the [WPT delete]. (Press the
[ ] key or [ ] key)
7
Move the position of characters to be reversed with the [ ] key or [ ] key.
Caution: If the values of latitude and longitude are not entered, they are registered as 0.
8
To end editing, press [GAIN (HF) Knob] or
[GAIN (LF) Knob].
9
After finishing the edit work, press the
[MENU] key.
10
Select the [registered] in the confirmation menu.
Edit end
Registered
Not registered
11
Press the [MENU] key. Then, the edit is finished.
5
Press the [ ] key.
6
Select the [Yes] in the confirmation menu.
(Press the [ ] key or [ ] key)
WPT delete
Yes
No
7
Press the [MENU] key. Then, the destination is deleted and the menu closes.
Recall the stored image and preset it as a destination
Recall the stored image in the past and it can be preset as a destination.
(See [1.9 Use of
[EVENT] key]
)
1
Press the [MENU] key.
2
Select [Image]
[Image recall]. (See [2.1
How to operate the menu].)
3
Press the [ ] key.
4
Select the image No. from the [Image
0093112802-06 2-9
Chapter 2 How to use the menu recall] list. (Press the [ ] key or [ ] key)
5
6
7
Image recall
No.
Comment
1 P IC 0 0 0 0 1
2 P IC 0 0 0 02
3
4
P
P
IC
IC
0
0
0
0
0
0
03
04
P IC 0 0 0 05
P
P
IC
IC
0
0
0
0
0
0
06
07
8
9
10
P IC 0 0 0 08
P IC 0 0 0 09
P IC 0 0 010
Caution: Chosen list NO. becomes yellow.
5
Press the [ ]key.
6
Move the cursor to the location preset as a destination with the[ ] key or [ ] key and select it.
L
H
Cursor(red line)
Caution: You can switch to other stored image with the [ ] or [ ] key.
7
When starting the NAV, press the [EVENT] key. When not starting the NAV, press the
[MENU] key.
CVS-128/128B
2.15 Store / Recall / Deletion of
Image
Store the image
The present image of echo sounder can be stored.
To memorize, it takes some time.
To memorize the image, the [EVENT] key must be switched to the [Store image].
1
Press the [MENU] key.
2
Select [System]
[EVENT key set]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Store image]. (Press the [ ] key or [ ] key)
EVENT key set
Store pos
Store image
Fishing hot spot
5
Press the [MENU] key to close the menu.
6
When the echo sounder image to be stored appears, press the [EVENT] key.
7
When the stored image is fully filled, it shows that the [Store image] is fully filled.
After deleting the unnecessary image, try it again.
Recall the stored image
The stored image in the past can be recalled.
During recalling, the image cannot be stored.
1
Press the [MENU] key.
2
Select [Image]
[Image recall]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the number of image to be recalled from the [Image recall] list. (Press the [ ] key or [ ] key)
5
6
7
Image recall
No.
Comment
1
2
P
P
I
I
C0
C0
0
0
0
0
0 1
02
3
4
P
P
I
I
C0
C0
0
0
0
0
03
04
P I C0 0 0 05
8
9
P
P
I
I
C0
C0
0
0
0
0
06
07
P I C0 0 0 08
P I C0 0 0 09
10
P I C0 0 010
Caution: Chosen list NO. becomes yellow.
5
Press the [ ] key.
Caution: When other stored image exists beside the recall image, switch to other image with the [ ] and [ ] key.
6
Press the [MENU] key to return to the normal menu.
Delete the stored image
The stored image in the past can be deleted.
To delete, it takes some time.
1
Press the [MENU] key.
2
Select [Image]
[Image delete]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the number of image to be deleted from the [Image delete] list. (Press the [ ] key or [ ] key)
Image delete
6
7
8
9
10
3
4
5
No.
Comment
1 PI C0 0 0 0 1
2 PI C0 0 0 02
PI C0 0 0 03
PI C0 0 0 04
PI C0 0 0 05
PI C0 0 0 06
PI C0 0 0 07
PI C0 0 0 08
PI C0 0 0 09
PI C0 0
010
5
Press the [ ] key.
6
Select the [Yes] in the confirmation menu.
Image delete
Yes
No
7
Press the [MENU] key.
Then, the preset image is deleted.
Add the comment to the stored image
It is convenient to judge the stored image.
1
Press the [MENU] key.
2
Select [Image]
[Image comment]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the number of image to which the comment is added from the [Image comment]. (Press the [ ] key or [ ] key)
8
9
6
7
10
2
3
4
5
Image comment
No.
Comment
1 PIC00001
PIC00002
PIC00003
PIC00004
PIC00005
PIC00006
PIC00007
PIC00008
PIC00009
PIC00010
5
Press the [ ] key.
6
Select the character with the [ ] key or [ ] key. (Character: A ~ Z, blank, 0 ~ 9, +, -./)
Image comment
No.
1
2
3
Comment
P I C00001
P I C00002
P I C00003
7
Select the comment position with the [ ] key or [ ] key.
0093112802-06 2-11
Chapter 2 How to use the menu
Image comment
No.
Comment
1
2
P
P
I
I
C0
C0
0
0
0
0
0 1
02
3 P I C0 0 0 03
8
To stop editing, press [GAIN (HF) Knob] or
[GAIN (LF) Knob].
9
After finishing the edit, press the [MENU] key.
10
Select the [register] in the confirmation menu.
Edit end
Registered
Not registered
11
Press the [MENU] key. Then, the edit is finished.
2.16 Explanation of Sonar
Switch-over of Sona-Tone
TM
The Sona-Tone
TM
can be output to the built-in speaker by selection.
The schools of fish and condition of bottom on the display of echo sounder can be confirmed by hearing the sonar.
1
Press the [MENU] key.
2
Select the [System]
[Sona-tone]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [ON] or [OFF] of [Sona-tone].
(Press the [ ] key or [ ] key)
OFF
ON
5
Press the [MENU] key to close the menu.
Connection of External Speaker
Connect the external speaker with amplifier
(option) so that you can hear the sonar easily.
Caution: The Sona-Tone
TM
is always output. Adjust the speaker volume with the volume provided on the speaker.
Caution: The external speaker is an option.
2.17 Explanation of Menu Item
The various items in the menu are explained.
Inner-hull
The reduction in sensitivity due to signal attenuation in inner-hull use can be corrected.
(Setting: - 50 ~ 50: through-hull: 0)
1
Press the [MENU] key.
2
Select the [Adjust]
[Gain (TD)]. (See
[2.1 How to operate the menu])
3
Press the [ ] key. The image displays bottom only. It may show very strong fish targets.
4
Set a value to display the sea bottom continuously without interruption. For high frequency, turn [GAIN (HF) knob] and for low frequency, turn [GAIN (LF) knob].
Gain (TD) L Gain (TD) H
CVS-128/128B
Bottom
Gain (TD)
5
Press the [MENU] key to close the menu.
Caution: Gain (TD) setting value widely varies upon installation conditions such as material of hull and installation method. Low frequency
(50 kHz) may not be used due to large signal attenuation in some cases.
TVG
The TVG adjusts the difference of strength between echoes reflected from the shallower depth and echoes reflected from deeper depth so that the reflection can be uniformed.
The deeper the depth is, the weaker the reflected signal of echo sounder becomes due to attenuation. Thus, comparing the signal reflected from the fish of the same size, the signal reflected from the fish in the shallower depth is stronger than that in the deeper depth.
The TVG adjusts the echo signal reflected from the shallower depth to be equal to that reflected from deeper depth by decreasing the receiver gain so that the effect that the strength of echo signal reflected from the shallower depth looks the same as that reflected from the deeper depth provided. The level of adjustment due to the depth increases in the order of weak → medium → strong. When set to "Strong", the
TVG provides strongest effect that reduces various noises around oscillation line.
1
Press the [MENU] key.
2
Select the [Adjust]
[TVG]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [weak], [medium], [strong].
(Press the [ ] key or [ ] key)
TVG
Weak
Medium
Strong
5
Press the [MENU] key to close the menu.
Caution: When the setting of [Gain select] is either one of [Cruising] or
[Fishing], it cannot be selected.
Change the TX power
The strength of transmission output (power) can be changed.
When the noise of interference with the neighboring echo sounder occurs, if the powers of transmission outputs at both sides are weakened, the interference noise can be suppressed.
1
Press the [MENU] key.
2
Select the [Adjust]
[TX power]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the [TX power]. (Press the [ ] key or [ ] key.)
TX power
20
40
50
60
70
80
90
100
Auto
5
Press the [MENU] key to close the menu.
Caution: In [Auto] setting, it controls transmission power automatically.
Change the Pulse width
Resolution and the detection distance change by changing the transmission pulse width. As for [Super short], the detection distance shortens though resolution goes up. As for
[Long], the detection distance becomes long though resolution falls.
1
Press the [MENU] key.
2
Select the [Adjust] → [Pulse width]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [Pulse width]. (Press the [ ] key or [ ] key.)
5
Press the [MENU] key to close the menu.
0093112802-06 2-13
Chapter 2 How to use the menu
Caution: When the fish symbol function is made effective, this function becomes invalid.
For CVS-128B
Change the Bandwidth
The bandwidth is automatically set according to the transmission pulse width. Please make it to
[Narrow] when you decrease the noise. Please make it to [Super narrow] when you decrease more.
1
Press the [MENU] key.
2
Select the [Adjust] → [Bandwidth]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [Bandwidth]. (Press the [ ] key or [ ] key.)
5
Press the [MENU] key to close the menu.
Caution: When the fish symbol function is made effective, this function becomes invalid.
For CVS-128B
D.Range
D.Range is to expand and narrow down the signal range from blue to red in images.
When the value is small, the expression range of strong and weak signal change is narrow, weaker signal will become undistinguished.
When the value is larger, the expression range is wider and the weaker signals become distinct.
(Setting: 12 to 30dB)
1
Press the [MENU] key.
2
Select the [Adjust] → [D.Range]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Change the setting of [D.Range]. (Press the [ ] key or [ ] key.)
5
Press the [MENU] key to close the menu.
For CVS-128B
CVS-128/128B
Display Width
When the image is zoomed or dual frequency displayed, the display width can be changed.
1
Press the [MENU] key.
2
Select the [D.range]
[Disp. width]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the width of image. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Display the A scope/Stop the display of A scope
The echo strength of latest echo can be displayed at the right side of echo sounder display.
The strength of echo sounder image is expressed by the horizontal width. This expression is called [A scope].
The width for strong echo is wide and the width for weak echo is narrow. This makes it easier for you to see the echo.
1
Press the [MENU] key.
2
Select the [Display1]
[A scope]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
To display the A scope, select the [ON].
To stop the display of A scope, select the
[OFF]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Change the display color of echo sounder image
The [Monochrome], [8 color], [16 color] and [64 color] can be selected.
1
Press the [MENU] key.
2
Select the [Display1]
[Color tone]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Color tone]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Change the depth value
The display size of depth value can be changed.
1
Press the [MENU] key.
2
Select the [Display1]
[Depth value].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the size of display. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Display the depth unit / Stop the display of depth unit
The depth unit can be displayed.
1
Press the [MENU] key.
2
Select the [Display1] → [Unit display]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
To display the depth unit, select the [ON].
To stop the display of depth unit, select the
[OFF]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Display the water temp graph/Stop the display of water temp graph
The latest water temp value and the graph of past water temp data can be displayed.
1
Press the [MENU] key.
2
Select the [Display1]
[Water temp graph]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
To display the water temp graph, select the
[ON].
To stop the display of water temp graph, select the [OFF]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Setting of the background color of
NAV display
The color of background of navigation display
(NAV1, NAV2) can be changed.
1
Press the [MENU] key.
2
Select the [NAV]
[Background color].
(See [2.1 How to operate the menu].)
3
Press the [ ] key.
4
Select the [Background color]. (Press the
[ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Setting of the echo sounder display at NAV display
The sounder display can be selected at NAV
(NAV 1, NAV 2) to be displayed.
1
Press the [MENU] key.
2
Select the [NAV]
[NAV1 (2)]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the echo sounder display at [NAV 1] or [NAV 2] to be displayed. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Image Swap
The images of echo sounder at the right and left sides can be swapped.
1
Press the [MENU] key.
2
Select the [Image]
[Image swap]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the swap state [A|B],[B|A]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Display the Operation guide/Stop the display of Operation guide
When displaying the menu, it sets whether or not the operation guide is displayed at the lower part on the display.
0093112802-06 2-15
Chapter 2 How to use the menu
When setting to “No display of operation guide”, the echo sounder image can be easily seen at the menu operation.
1
Press the [MENU] key.
2
Select the [System]
[Operation guide].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
To display the Operation guide, select [ON].
To stop the display of Operation guide, select [OFF]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Display the detection area/Stop the display of detection area
The range of the search that can be detected in the angle of beam spread of the transducer used can be displayed.
1
Press the [MENU] key.
2
Select the [Display2]
[Detection area].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
To display the Detection area, select [ON].
To stop the display of Detection area, select [OFF]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Caution: The beam angle of transducer is different depending on the transducer. (See [3.3 Setting of
Correct Item, Directirity angle
(Low/High)].)
Setting of Scale display
The set of the scale display
1
Press the [MENU] key.
2
Select the [Display2]
[Scale display].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Scale display]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
CVS-128/128B
Change the scale value
The display size of the scale value can be changed.
1
Press the [MENU] key.
2
Select the [Display2]
[Scale]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the [Scale]. (Press the [ ] key or
[ ] key)
5
Press the [MENU] key to close the menu.
Change the image direction
The direction of display image can be changed.
1
Press the [MENU] key.
2
Select the [Display2]
[Image direction].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Image direction]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Setting of Depth measurement
Select the method for depth measurement, which is shown on the display.
1
Press the [MENU] key.
2
Select the [Display2]
[Bottom detection].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Bottom detection]. (Press the
[ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Change the display color
The display color can be changed.
1
Press the [MENU] key.
2
Select the [Display2]
[Color table 1] or
[Color table 2]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Color table]. (Press the [ ] key
or [ ] key)
5
Press the [ ] key.
6
Select the color. (Press the [ ] key or [ ] key)
7
Press the [MENU] key to close the menu.
Setting of Key lock
Disable the functions of controls and keys to avoid deviation of these settings by unintentionally touching them during operation.
1
Press the [MENU] key.
2
Select the [System]
[Key lock]. (See [2.1
How to operate the menu])
3
Press the [ ] key.
4
Select the [Key lock]. (Press the [ ] key or
[ ] key)
5
Press the [ ] key.
6
Select the [ON] or [OFF]. (Press the [ ] key or [ ] key)
7
Press the [MENU] key to close the menu.
Change the scale type
The interval of indications of scale can be changed.
1
Press the [MENU] key.
2
Select the [Display2]
[Scale type]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Scale type]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Change the bottom color
The dark red color of sea bottom can be changed.
1
Press the [MENU] key.
2
Select the [Display2]
[Color table 2]
[Bottom color]. (See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Bottom color]. (Press the [ ] key or [ ] key)
Black
0, , , 176, , , 255 Red
5
Press the [MENU] key to close the menu.
Change the image partition
The image partition of echo sounder can be change to "Horizontal split" or “Vertical split”.
1
Press the [MENU] key.
2
Select the [Image]
[Image partition].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [Image partition]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
Display the frequency / Stop the display of frequency
The frequeny of the transducer currently in use can be displayed.
1
Press the [MENU] key.
2
Select the [Display2] → [Freq display].
(See [2.1 How to operate the menu])
3
Press the [ ] key.
4
To display the Freq display, select the [ON].
To stop the display of Freq display, select the [OFF]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
For CVS-128B
Selecting a display area of fish symbol indication
The fish symbol can be displayed either on side
A or on side B, or on both sides, by the following operation.
1
Press the [MENU] key.
2
Select the [Image]
[Fish image]. (See
[2.1 How to operate the menu])
3
Press the [ ] key.
4
Select the [A|B], [A| ], [ |B]. (Press the [ ] key or [ ] key)
5
Press the [MENU] key to close the menu.
0093112802-06 2-17
CVS-128/128B Chapter 3 How to use the menu2
Chapter 3 How to use the menu2
After powering on, besides the menu displayed first with the [MENU] key, there are the other menus as follows, of which setting does not need to be frequently changed.
[In out], [Correct], [Setting], [Maintain]
Display the menu
1
Press the [MENU] key.
2
Select the [Next].
Adjust
D.range
Display1
Display2
Alarm1
Alarm2
NAV
Image
System
Freq*
Next
* For CVS-128B
In out
Correct
Setting
Maintain
Adjust2
3
Press [ ] key to display the system menu.
Prev
In out
Correct
Setting
Maintain
Adjust
D.range
Display1
Display2
Alarm1
Alarm2
NAV
Image
Freq*
System
* For CVS-128B
Return to the normal menu
1
Select the [Prev].
2
Press the [ ] key to display the normal menu.
3.2 Setting of External Input /
Output
Set the setting related to the input/output.
Prev
In out
Correct
Setting
Maintain
Buzzer setting
Temp source
Speed source
Baud rate
NMEA monitor
NMEA output data
NMEA output data
Return
OFF
InsideSensor
InsideSensor
4800
OFF
Buzzer Setting
Set the buzzer sound to ON/OFF.
Temp Source
Switch the Sensor/NMEA.
For setting of [SENSOR], use an internal water thermometer connected to the water temperature sensor with J6 connector.
For setting of [NMEA], use the input value from outside connected with NMEA of power connector.
Speed Source
Switch the Sensor/NMEA.
Use the built-in speed meter for sensor.
Use the external input value for NMEA.
Baud Rate
Change the transmission speed of external input/output.
Match the transmission speed with that of external equipment connected. (Setting: 4800,
9600, 19200, 38400)
0093112802-06 3-1
Chapter 3 How to use the menu2 CVS-128/128B
NMEA Monitor
The external input data can be displayed.
To return to the original menu, press the [MENU] key.
Caution: When [GAIN (HF) Knob] is pressed, the displayed data will stop.
NMEA Output Data
The output of NMEA sentence can be set to
ON/OFF.
1
Select [In out]
[NMEA output data]. (See
[2.1 How to operate the menu].)
2
Press the [ ] key.
3
Select the sentence name.
4
Press the [ ] key.
Prev
In out
Correct
Setting
Maintain
Prev
DBT
DPT
GGA
MTW
TLL
VHW
VTG
ZDA
Return
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
5
Select the ON/OFF.
DBT
OFF
ON
6
Press the [ ] key to turn to the display to select the sentence name.
7
Further pressing of [ ] key turns to the display to select the NMEA output.
8
Press the [MENU] key to close the menu.
3.3 Setting of Correction Item
Prev
In out
Correct
Setting
Maintain
Draft set
Sonic speed
Water temp
Boat speed
Beam width H
Beam width L
Size adjust
Detect adjust f
Bubble
Bubble time set
Return
0.0m
Seawater
0.0°C
0%
17°
50°
6
4
OFF
5 minutes
Draft Set
The tolerance of depth can be corrected.
Set the depth from the sea level to the set depth of your transducer. Normally set draft value of your boat. (Setting: expect ft: - 10.0 to 10.0, ft:
-30.0 to 30.0)
Sonic Speed
Set the [Seawater] or [Freshwater].
Change to meet the usage.
Water Temp
The error of water temp value can be corrected.
(Setting: - 10.0 to 10.0 ˚C, - 10.0 to 10.0 ˚F)
Boat Speed
The tolerance of boat speed value can be corrected.
When the [Speed source] is set to [Sensor], it is corrected by %. (Setting: - 50 to 50 %)
When the [Speed source] is set to [NMEA], it is corrected by numeral. (Setting: - 10.0 to 10.0)
Directivity angle (Low/High)
Directivity angle of transducer which you use should be input for high and low frequency respectively.
3-2
CVS-128/128B Chapter 3 How to use the menu2
Bubble
Bubble-prevention process can be activated by setting [Weak] or [Strong].
Bubble time set
While auto-range or auto-shift is in use, and if the missing image is caused by bubble, range and shift continues changes until sea bottom is detected by auto mode.
Setting the bubble time duration holds the range or shift at the level when bubble started.
If bubble disappears and sea bottom is detected, range or shift returns to auto mode.
This makes the time shorter until the image comes back to normal. After the specified time, the mode returns to the previous auto-range or auto-shift. (Setting: OFF, 1minutes to 10minutes)
3.4 Setting of Basic Set Item
Prev
In out
Correct
Setting
Maintain
Language English
Range&Speed unit
NM,kn
Depth unit m
Temperature unit
Localtime offset
GPS select
GPS initialize
Return
°C
0.0
Others
No
Temperature Unit
It switches the unit of temperature to ˚C, °F.
Local time Offset
The local time offset can be set by 0.5 hours (30 minutes) unit. (Setting: - 11.0 to 14.0 h) (UTC: 0.0)
GPS select
It selects whether the GPS sensor is the KODEN made one or not.
Caution: Only when connecting the
Koden GPS sensor to the equipment directly, select [KODEN GPS].
When connecting the GPS sensor even Koden one) via Plotter etc to the equipment, select [Other].
GPS initialize
It is valid only when KODEN GPS is connected.
The GPS sensor is initialized.
Caution: When connecting the GPS sensor other than KODEN GPS, do not use this item.
Language
Switch to the language to be displayed.
Caution: [ Language ] is displayed in red characters.
Range & Speed Unit
It switches the display unit to [NM, kn] or [km, km/h].
Depth Unit
It switches the unit of depth to m, fm, l.fm and ft.
Prev
In out
Correct
Setting
Maintain
Simulation
Slideshow
Initialize
System check
All WPTs:DLT
All IMG DT:DLT
Bottom start
Past image*
Inner-hull
TD select*
Return
* For CVS-128B
OFF
OFF
No
1.5
ON
No
TDM-091D
Simulation
When the [Simulation] is set ON, the pseudo image of echo sounder is displayed.
0093112802-06 3-3
Chapter 3 How to use the menu2 CVS-128/128B
Slide show
The slide show of the images stored in
[Image]
[Image recall] is available. The time intervals for image changeover can be selected from 15 seconds and 30 seconds.
Caution: To perform slide show, registration in the list of image memory is required. When it is not registered, slide show cannot be selected.
Initialize
It returns all the settings in the menu to the factory settings. However, the memorized data of display remains unchanged.
Caution: It returns to the factory settings and the power is automatically shut down.
System Check
It is used for diagnostic test.
(See [4.5 Dia gnostic Test]
)
All WPTs deletes
All WPT lists can be deleted.
All stored image deletes
All stored image lists can be deleted.
Bottom start
Set up the starting depth of the seabed detection.Once set, the fish echo or the seabed shallower than set up depth will not be detected.
Past image
When the [Past image] is set to ON, the gain control is effective for all screens including the past image.
When the [Past image] is set to OFF, the gain control is effective for current image only.
For CVS-128B
Inner-hull
When the installation of a transducer is
[Inner-hull], select the [Yes].
Caution: When a setting is altered, the value of Gain (TD) will be initialized.
TD select
Choose the installed transducer (TD) in the menu list.
Caution: When transducer is choosen by model name, [Beam angle] value
(directivity angle) is changed automatically depending on the transducer.
For CVS-128B
3.6 Setting of Adjust2 Item
Prev
In out
Correct
Setting
Maintain
Adjust2
STC strength H
STC depth H
STC strength L
STC depth L
Color adjust
Image speed adj
Bottom limit
Return
0.0
50
0.0
50
0
1.0
The visivility of the fish school echo can be adjusted by STC setting.
Adjustment can be done for high-frequency and low-frequency independently.
STC strength adjust Low / High
Set smaller values for higher sensitivity.
STC depth adjust Low / High
Depth limitation of STC adjustment.
Unit: Meter
STC can be operated from 0 to the setting depth.
3-4
CVS-128/128B Chapter 3 How to use the menu2
Color adjust
Rainbow pattern of the echo image can be changed.
Set the value of each color in the range from 0 to
99%. Confirm color distribution by the rainbow pattern of the left side of the screen.
Prev
In out
Correct
Setting
Maintain
Adjust2
Prev
Red
Orange
Yellow
Green
Sea green
Light blue
Marine blue
Return
95
90
60
30
20
15
5
EXAMPLE:
When the yellow value is change from 60 to 80 in the setting, the Rainbow pattern becomes as shown below.
Before the change
After the change
Image speed adjust
The image speed can be adjusted.
The image speed becomes faster in a minus direction, and slower in a plus direction.
Caution: Image speed cannot set faster than the maximam speed value.
Bottom limit
The detection of sea bottom can be changed.
Sea bottom can be detected up to the range of display multiplied by the setting value.
EXAMPLE:
Displayed 20 m, setting value: 2.0, a bottom can be detected up to approximetery 40m.
Caution: If the setting value is increased, the image speed becomes slower.
Sounding
Sounding is performed up to the maximum depth set during auto range is in operation.
The maximum range is 800 m. At the initial setup, the range is up to 200 m for CVS-128 and up to
500 m for CVS-128B. (Setting: m: 10 to 800, I.fm:
10 to 600, fm: 10 to 400, ft: 10 to 2800)
Adjust
D.range
Freq select (L)*
Freq select (H)*
Display1
Display2
Power freq adj*
Return
Alarm1
Alarm2
NAV
Image
System
Freq*
Next
* For CVS-128B
42.0
210.0
107.0
Frequency select (Low / High)
The frequency of the connected transducer (low frequency and high frequency) is chosen.
Caution: When the frequency out of the specified range is choosen, the setting value is displayed in a faded color.
For CVS-128B
Caution: Do not choose a frequency different from the frequency of the connected transducer.
0093112802-06 3-5
Chapter 3 How to use the menu2
Power frequency adjustment
It is necessary to adjust power frequency when noise appears on the image. The value for adjustment depends on the frequency of the transducer.
Caution: Power frequency adjustment is for internal noise, so there is no effect for external noise.
For CVS-128B
CVS-128/128B
3-6
CVS-128/128B Chapter 4 Maintenance and Inspection
Chapter 4 Maintenance and Inspection
4.1 Inspection
The daily maintenance and inspection extends the life of equipment. To always keep the equipment in the best condition, implement periodically the inspection shown in the table below.
Item
Connector at the rear of
CVS-128/128B Display unit
Wiring of cables
Check the looseness.
Content of Inspection
Check the wiring of cables connecting the equipment and the damage of cable.
Scrape the rust off the ground terminal and make its contact well. Grounding of display unit
4.2 Cleaning
CVS-128/128B Display unit
Contamination on the screen may cause faint images. For cleaning the screen, wipe the screen with soft and clean cloth dipped with diluted neutral detergent. Pay full attention as the screen is easily getting scratched. No thinner shall be used.
Caution
The display unit has a special coating. Do not use a solvent such as paint thinner, acetone, alcohol, and benzene, etc.
Strong rubbing may cause bruising or scratching.
For cleaning the housing, do not use plastic solvent such as thinner or alcohol. Painting on the surface and characters at the operating portion may melt. After wiping with soft and clean cloth dipped with diluted neutral detergent, wipe away with dry soft and clean cloth.
Transducer
In case of through-hull equipped transducer, check the surface of opening of transducer (portion from which the ultra-sonic is emitted). If shells and oil are stuck, scrub the surface with a wooden or bamboo knife with caution not to damage the surface and remove stuck materials. If you scrub strongly, the surface will be damaged, resulting in deteriorated performance of transducer.
0093112802-06 4-1
Chapter 4 Maintenance and Inspection CVS-128/128B
Warning
Use the specified fuse. If you use a fuse other than specified one, it may lead to a serious accident.
If the input voltage is too high, the over-current flows or a trouble occurs inside, the fuse will blow out.
The fuse is housed in the power cable.
4.4 If you suspect a trouble
Symptom
Even if the power is powered on, nothing is displayed.
The unit starts up. But, nothing is displayed on the display.
Possible cause of trouble
Blown fuse.
The power voltage is out of specification (10.8 to 31.2
VDC).
Poor connection between power cable and battery.
Connection between transducer and display unit.
Defect of LCD display block.
Too much interference and noise.
Installed position of transducer.
Interference from the echo sounder on other boat.
Countermeasure
Exchange a fuse.(See [4.3 Fuse
Replacement])
Use a proper power as per specification.
Confirm a connection between the power cable and the battery.
Confirm a connection between
Transducer and Display unit.
Consult a repair shop or the distributor in your market.
Confirm the position of transducer.
(See [5.3 Installation of
Transducer])
Apply the interference rejection.
(See [2.3 Rejection of
Interference])
Confirm the connection of the sensor connector.
Confirm the input source.
The display of water temperature / boat speed is abnormal or not displayed.
Connection of sensor connector.
Input source of water temperature sensor / speed sensor.
Connection between this unit and navigation equipment.
The display of present location/course is abnormal or not displayed.
Confirm a connection between
Display unit and the navigation equipment.
CVS-128/128B Chapter 4 Maintenance and Inspection
Perform the operation diagnosis.
To check the operation diagnosis of panel key, the state of sensor inside and the version of software.
Confirm the version
3 displays the information on the version of software.
When inquiring, inform us of Ver XX.XX.
KM-E79 Ver.xx.xx in case of CVS-128
KM-F22 Ver.xx.xx in case of CVS-128B
Return to the menu
Press the [MENU] key for more than 3 seconds.
LCD Test
Diagnose
1 displays the diagnostic result.
The result of ROM and RAM check displays
OK when normal and NG when abnormal.
Caution: To test the NMEA, TEMP and
SPEED, the special checker is necessary.
2 implements the key input test. When pressing the key, the color of a part corresponding to the pressed key changes.
When pressing the [GAIN (HF)], the LCD test is performed.
0093112802-06 4-3
CVS-128/128B Chapter 5 Installation
Chapter 5 Installation
5.1 Items of Caution on Installation
To realize the full performance of echo sounder, the installation of CVS-128/128B must be performed by an engineer who is officially authorized by our company. The installation work includes the following content.
(1) Unpacking the components
(2) Inspection of configuration unit, spare, accessories and material for installation
(3) Check of power voltage and capacity of current
(4) Decision of installing location
(5) Installation of Display unit and transducer
(6) Installation of accessories
(7) Plan and execution of cable laying and connection
(8) Adjustment after completion of installation
Unpacking the components
Unpack the components and confirm that all of the items match with the contents on the equipment configuration list. If not matched, contact the dealer you purchased or our sales company.
Inspection of components and accessories
Inspect the appearance of each components and accessories and check that no dents or damage exist.
If any dents or damage exist and they are believed to be caused by accident during transportation, contact the transportation and insurance company and consult our sales company or our dealer nearest to you.
Decision of Installing Location
To realize the full performance of equipment, install the equipment, considering the points mentioned below.
(1) Install the equipment at the location in the bridge so that its display can be easily seen.
(2) Select a safe location where the equipment is not exposed to humidity, water splash, rain and direct sunshine.
(3) Keep enough space for maintenance. Especially, secure enough space at the rear panel where many cables are concentrated.
(4) Keep the equipment as far away from the wireless transmitter/receiver as possible.
The equipment is not waterproof. Avoid excessively damp place. Do not install the equipment in the place suffering from excessive waterdrops. Otherwise, the corrosion may occur inside.
0093112802-06 5-1
Chapter 5 Installation CVS-128/128B
Laying and Connection of Cable
(1) Keep the transducer and power cable as far away from the cables of other electronic equipment as possible.
(2) The cabinet of Display unit shall be securely grounded to the hull, using the ground terminal on the rear panel.
Caution: The ground side of power input of this equipment is connected to the ground terminal.
In case of + (positive) ground, it cannot be used. The power may short-circuit.
(3) If you connect the power cable directly to the battery, the interference from other electronic equipment is not subject to occurrence. (See Fig. 5.1.)
Display unit
Display unit
Good example Bad example
CVS-128/
CVS-128B
CVS-128/
CVS-128B
Battery Battery
Noise
Noise
Fig. 5.1 Connection of Power Line
Confirmation after Installation
Be sure to confirm the following items before starting up this equipment. The confirmation is mandatory to operate the equipment normally.
(1) Is the power voltage in the boat within the appropriate voltage range? Is the current capacity enough?
Voltage Range: 10.8 to 31.2 VDC when measured at the power connector input.
(2) Is the electric current capacity sufficient? (Power consumption: 25 W)
(3) Is the wiring of transducer cable correct? Is the wiring shorted?
CVS-128/128B Chapter 5 Installation
5.2 Installation of CVS-128/128B Display unit
CVS-128/128B Display unit can be installed either on desk-top or flush-mounted.
Install in the following procedure.
Desk-top Installation
(1) Remove two knob bolts fixing the display unit to the bracket.
(2) Remove the display unit from the bracket and place it on the stable flat place.
(3) Place the bracket on the position where the display unit will be installed and fix the bracket with five
5 mm screws.
(4) Place the display unit on the installation bracket and fix the display unit with two knob bolts removed in step 1.
Display unit
Installation bracket
Knob bolts
(4 5
125
9/6
4)
Fig. 5.2 Desk-top installation
(4 5
125
9/6
4)
41
9/6
4)
41
(1
39
/64
) (
1 3
Unit: mm (inch)
0093112802-06 5-3
Chapter 5 Installation CVS-128/128B
Caution: When installing on the desktop, the maintenance space shown in the illustration below is required for cable lay-out, plugging-in/out of connector, fuse replacement and bolt tightening.
Fig. 5.3 Maintenance space
CVS-128/128B Chapter 5 Installation
Flush-mount Installation
(1) Make a square hole at the location to be installed. (See Fig. 5.5.)
(2) Turn counter-clockwise the knob bolt fixing the display unit to the mounting bracket to loosen it, push the unit to the left side and pull the unit upward. The mounting bracket and knob bolt are not used.
(3) Confirm that the unit matches with the square holes. If not matched, correct the square hole.
(4) Remove the front frame of the display unit, pulling it toward you. (See Fig. 5.4.)
(5) Connect the connectors for power and transducer to the unit respectively.
(6) Install the display unit in the installing location (square hole) and fix it with four tapping screws
(4mm) (M4 or pan-head). (Prepare 4mm screws suitable for thickness of installing location.)
(7) Install the front frame removed in step (4).
(8 2
220
1/3
2)
Threading hole
Fig. 5.4 Flush-mount Instsllation
Unit:mm (inch)
4-4mm (4-5/32)
Hole for screw
220
(8 21/32)
R
25 (63/
64)
Threading hole
224
(8 13/16)
Unit: mm (inch)
Fig. 5.5 Work of fiush-mount instsllation hole
0093112802-06 5-5
Chapter 5 Installation
The standard installation of the transducer is shown in figure 5.6.
CVS-128/128B
Figure 5.6 Installation of Transducer
In case of Inner-hull
Using the optional inner-hull kit (MFB-04), install the transducer to the inner side of ship’s bottom.
Caution on installation
Figure 5.7 Inner-Hull installation
(1) Select the location where no bubble is generated during navigation.
(2) Select the relatively thin location of ship’s bottom.
(3) Be sure to remove oil on the contact surface. File the contact surface with sand paper (#400) so that the adhesive strength will increase.
(4) The adhered surface will dry in about two hours.
(5) Leave the unit for a whole day and fill in the coolant. More than 80 % of the transducer should be submerged in the coolant.
Caution: It is strongly recommended to confirm the location of the installation of Inner-hull with the ship manufacturer. The Inner-hull device is more simplified method. The gain falls dramatically in comparison with the Through-hull performance. Low frequency (50 kHz) may not be used due to large signal attenuation in some cases. Depth range performance using 200 kHz Transducer in case of Inner-hull can be less about 50% than that of Through-hull.
Caution: Fishing boats may have structure with FRP contained air bubbles and foamed materials that would prevent ultrasound from penetration. Therefore, the location convenient for installation may not be locations where attenuation of ultrasound is low enough.
CVS-128/128B Chapter 5 Installation
In case of Through hull
Install the transducer directly to the ship’s bottom
Installation Procedure
(1) Select the installing location.
(2) Remove the fixing nut and one piece of rubber packing.
(3) If the slope of ship’s bottom is greater than 5°, make a wooden base to fit to the slope of ship’s bottom. To reduce the water resistance, cut the bow direction tip of wooden base at the outer side of ship’s bottom in the triangle shape.
(4) Make holes at the installing location. If the wooden base is used, make holes in the wooden base.
(5) Thread the rubber packing in the transducer and then the cable.
(6) To prevent water from seeping through the gap between the transducer and the hole, fill out the gap with FRP or silicon glue. (Glue the wooden base likewise.)
(7) Thread the rubber packing and fix it with the fixing nut firmly.
(8) Connect the transducer cable to the connector of Display unit.
Fixing nut
Rubber packing
Fixing nut
Rubber packing
Wooden base
Ship
, s bottom
Rubber packing
Wooden base
Rubber packing
Transducer
Ship
, s bottom
Less than 5
In case that the slope of ship
, s bottom is less than 5
Transducer
In case that the slope of ship
, s bottom is greater than 5
Figure 5.8 Through-hull Installation
0093112802-06 5-7
Chapter 5 Installation CVS-128/128B
5.4 Wiring
Connection of Cable to CVS-128/128B Display unit
Connect the power cable and transducer to the connectors of CVS-128/128B Display unit.
・Power input
10.8 to 31.2VDC
・NMEA data input output
GPS, plotter etc
・Sona-Tone
TM
・Power output
output
Line output for speaker with amplifier
For power of GPS etc
・Transducer
For 50/200kHz in common
・Speed sensor data input
・Water temperature sensor data input
・External monitor
Analog RGB
Pin Assignment of Rear Connector
Pin assignment viewed from the rear of Display unit.
POWER
Sona-Tone
TM
R
Sona-Tone
TM
L
Power +
Outside power (-)
NMEA TX-
NMEA TX+
NMEA RX+
NMEA RX-
Power -
Shield
Sona-Tone
TM
COM
Outside power (+)
J6
J7
Caution: Do not connect each wire to ship’s earth.
Speed sensor input
Speed sensor power (+)
Transducer input output
Transducer shield
Transducer input output
Water temperature sensor power
Water temperature sensor input
Speed sensor power (-)
R
R-GND
G
G-GND
B
B-GND
H-SYNC
V-SYNC
Un-connected
Un-connected
CVS-128/128B Chapter 5 Installation
Connection of Power Cable
Connect the power cable to the [POWER] connector and the transducer to the [J6] at the rear of
Display unit connector.
Connection of DC power cable (CW-264A-2M)
3.5 stereo jack
To [POWER] connector
DC+ (Red)
DC- (Black)
Caution: Wind the insulation tape around the un-used lead wire for core-wires not to contact each other.
Grounding
Use heavy gauge cable for grounding wire.
Connect the grounding wire to the grounding material in a short distance.
When connecting the external equipment of which positive polarity is connected to the ground line, do not connect the ground of signal line to the cabinet ground.
0093112802-06 5-9
Chapter 5 Installation CVS-128/128B
Connection of Transducer
At the end to the transmission/receiving cable for TD-500T-2B, TD-500T-3B, TD-501T-3B, TDM-071 and TDM-091D a water proof connector with 8-core is provided.
At the end to the transducer for TD-501C is plain.
1) TD-500T-2B/500T-3B/501T-3B/TDM-071/TDM-091D
Connect to the J6 connector on the back of the receiver display unit.
2) TD-501C
The user must have the cable, CW-840-0.3M for the transducer.
Solder the transducer to CW-840-0.3M while referring to the table on connecting transducers.
After soldering is completed, please be sure to add water-resistance and insulation by applying electrical tape (or other such tape) onto the soldered part of the cable.
Transducer Connection Table
Transducer Cable
2 lead shield wire number 2 lead shield wire color
Transducer
TD-501C
CW-840-0.3M 2 lead shield
3 TD1 (orange)
Lead wires
4 Shield
5 TD2 (white)
To Transducer
1 SPD.PULSE (blue)
2 SPD.VCC (violet)
8 SPD.GND (black)
6 TEMP.VCC (green)
7 TEMP.SIG (red)
To Speed Sensor
To Temperature Sensor
Caution: Wind the insulation tape around the un-used lead wire for core-wires not to contact each other.
CVS-128/128B Chapter 5 Installation
Connection with external equipment
The DC power cable contains the connection cables for external equipment such as navigation equipment and KODEN GPS sensor.
Color Pin Remark Color Pin Remark
Sona-Tone
TM
White 7 NMEA RX +
Green 8 NMEA RX -
Connection with GPS-20A
(with ø3.5 stereo jack)
Black 11
Yellow 12 Outside power (+)
Gray 4 Outside power (-)
Shield 10
After soldering, implement the waterproof and insulation treatment on the connected part with the self-melting tape.
CVS-128/128B
DC power cable
(CW-264A-2M)
GPS-20A (No Type)
Connecting up without using a connector
GPS-20A (Type B)
Connecting up using a connector*
Color Remark
Orange NMEA TX +
Blue NMEA TX -
White NMEA RX +
Green NMEA RX -
Yellow Outside power (+)
Gray
Outside power (-)
Color
Orange
Blue
White
Green
Red
Black
Pin
2
3
4
5
6
1
*Optional connector (LTWBD-06PMMP-LC) is necessary.
0093112802-06 5-11
Chapter 5 Installation CVS-128/128B
Connection with Speed Sensor or Water Temperature Sensor (Option)
When installing the optional speed sensor or water temperature sensor, connect to the [J6] connector together with the transducer via the transducer cable (Type: CW-840-0.3M). For wiring, see the figure below.
After soldering, implement the waterproof and insulation treatment on the connected part with the self-melting tape.
Structure of Transducer Cable
2 core shield wire
TD1 (Orange)
To Transducer
Shield
TD2 (White)
SPD.PULSE (Blue)
SPD.VCC (Violet)
To the speed sensor
SPD.GND (Black) lead wire
TEMP.VCC (Green)
TEMP.SIG (Red)
To the water temperature sensor
Caution: Wind the insulation tape around the un-used lead wire for core-wires not to contact each other.
Connection Table of Transducer
Transducer Cable
No. of 2 core shield Color of 2 core shield TD-500T-2B
TD-500T-3B
Transducer
TD-501T-3B
TD-501C
4 Shield Shield Shield
5 White White White
Connection Table of Speed Sensor and Water Temperature Sensor
Transducer Cable
No. of lead wire
Color of lead wire
Water Temperature Sensor / Speed Sensor
T-81 ST-80
ST-80-1
ST-90
ST-90-1
ST-100
ST-100-1
Green Green Green
Caution: No.8, SPD.GND (Black), only use for speed sensor.
Do not connect with other grounding wire.
CVS-128/128B Chapter 5 Installation
Connection of External Speaker for Sona-Tone
TM
(Prepared by a customer)
The ø3.5 stereo jack is provided to the power cable.
If you connect the speaker with the amplifier to the external, you can clearly hear the Sona-Tone
TM sound.
Adjust the volume of speaker with the amplifier equipped to the speaker
3.5 stereo jack
Connection of External Monitor (J7) (Prepared by a customer)
When installing an external monitor (VGA monitor, analog RGB input), connect it via CW-576-0.5M. For its wiring, refer to the illustration below.
Structure of CW-576-0.5M
Nonuse
0093112802-06 5-13
Chapter 5 Installation CVS-128/128B
Input Data
The sentences of GGA, GLL, HDT, MTV, MWV, RMC, VHW, VTG and ZDA can be received.
The type of NMEA0183 Ver.1.5, Ver.2.0 and Ver.3.0 can be input.
Information
Latitude,
Longitude
Course
Priority Order of Sentence
GGA > RMC > GLL
VTG > RMC
Heading HDT
Ground Speed VTG > RMC
Water Speed VHW
Information
Wind Direction
Wind Speed
Date
Time
Water
Temperature
Priority Order of Sentence
MWV
MWV
ZDA > GGA
MTW
Output Data
The sentences of DBT, DPT, GGA, GLL, HDT, MTW, MWV, RMC, TLL, VHW, VTG and ZDA can be transmitted.
The output is performed in the type of NMEA0183 Ver.2.0. However, the DBT is performed in Ver.1.5.
Sentence Information
DBT Depth
DPT
Sentence
MWV
Depth from the transducer RMC
Information
Wind Direction, Wind Speed
Latitude/Longitude, Course,
Ground Speed, Date
GLL Latitude/Longitude Speed
HDT Heading VTG Course, Ground Speed
Date,Time
CVS-128/128B Chapter 6 Table Attached
Chapter 6 Table Attached
The factory set value is shown by the bold and underline.
[Disp] key
Disp
【 ▲RANGE▼】key
RANGE
[GAIN(HF) ], [GAIN(LF) ]
Gain select
Auto adjust
Gain
[BRILL] key
LCD brill
Panel brill
[EVENT] key
[F1] key
[F2] key
NAV1, Normal (H), Zoom (H), Dual freq, Zoom (L), Normal (L), NAV2
Auto range, 5.0, 10.0, 20.0, 50.0, 100, 160, 300, 500, Auto shift
Manual, Cruising, Fishing
- 30 to 10 (H): 0, (L): 0
0.0 to 10.0 (H): 6.0, (L): 6.0
1 to 10: 10
1 to 10: 10
Store pos, Store image, Fishing hot spot
Image speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV1, NAV2, Image swap, Image recall, Sona-tone
Image speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV1, NAV2, Image swap, Image recall, Sona-tone
0093112802-06 6-1
Chapter 6 Table Attached CVS-128/128B
[MENU] key
Adjust
D.range
Display1
Display2
Image speed
(Speed1, Speed2, Speed3, Speed4, Stop, Speed5 (1/1), Speed6, Speed7,
Speed8, Speed9)
IR (OFF, Weak, Strong : Strong (For CVS-128) , Weak (For CVS-128B))
Color rejection (0 to 50 %: 0%)
Noise rejection (0 to 10: 0)
TVG (Weak, Medium, Strong)
TX power (20, 30, 40, 50, 60, 70, 80, 90, 100, Auto)
Gain (TD) (-50 to 50) Inner-hull : No
H: 0, L: 0
Inner-hull : Yes
H: 15, L: 30
Pulse width (Super short, Short, Middle, Long) (For CVS-128B)
Band width (Super narrow, Narrow, Middle) (For CVS-128B)
D.Range (12dB to 30dB: 24dB) (For CVS-128B)
Shift step (1m, 10m, 1/8, 1/4)
Zoom type
(Bottom, Bottom Discrimination, Zoom, Bottom Zoom, Bottom Follow Zoom)
Zoom range (2.5 to 200 m: 10.0 m)
Zoom start (0 to 800 m: 0m)
Disp width (Left2, Left1, Center, Right1, Right2)
Range preset
Inner-hull : No
Range 1 (2.5 to 1200 m: 5.0)
Range 2 (2.5 to 1200 m: 10.0)
Range 3 (2.5 to 1200 m: 20.0)
Range 4 (2.5 to 1200 m: 50.0)
Range 5 (2.5 to 1200 m: 100)
Range 6 (2.5 to 1200 m: 160)
Range 7 (2.5 to 1200 m: 300)
Range 8 (2.5 to 1200 m: 500)
Inner-hull : Yes
Range 1 (2.5 to 1200 m: 5.0)
Range 2 (2.5 to 1200 m: 10.0)
Range 3 (2.5 to 1200 m: 20.0)
Range 4 (2.5 to 1200 m: 50.0)
Range 5 (2.5 to 1200 m: 80)
Range 6 (2.5 to 1200 m: 100)
Range 7 (2.5 to 1200 m: 160)
Range 8 (2.5 to 1200 m: 200)
A
A scope (OFF, ON)
White line (OFF, 1, 2, 3, 4, 5, Auto)
Background color (Pale blue, Marine blue, Blue, Dark blue, Black, Darkkhaki,
Mediumseagreen, Light grey, White, Night mode)
Color tone (Monochrome, 8 color, 16 color, 64 color)
Depth value (OFF, Small, Middle, Large)
Unit display (OFF, ON)
Water temp graph (OFF, ON)
Fish symbol (OFF, Symbol 1 to Symbol 10)
Symbol info (OFF, Depth, Size, Bottom<=>Fish)
Detection area (OFF, ON)
Scale display (OFF, One, All)
Scale
(
Small, Middle, Large
)
Image direction (←|← , →|→ , ←|→)
Bottom detection (Auto, High frequency, Low frequency)
Color table1 (Header information, Header BG color, VRM, Depth, Scale,
Scale line,Detection area H, Detection area L)
Color table2 (Symbol info, Menu BG color, Big fish color, Bottom color)
Scale type (0, 1)
Big fish (20 to 90: 50)
Freq display (OFF, ON) (For CVS-128B)
6-2
CVS-128/128B
A
B
Alarm 1
Alarm 2
NAV
Image
System
Freq
0093112802-06
Chapter 6 Table Attached
Bottom alarm (OFF, ON)
Upper depth (0 to 800 m: 5 m)
Lower depth (1 to 800 m: 50 m)
Fish alarm (OFF, ON)
Position (0 to 800 m: 5 m)
Range (1 to 800 m: 50 m)
Level (Weak, Medium, Strong)
Water temp alarm (OFF, ON (Inside), ON (Outside))
Upper temp alarm (- 5 to 45.0 °C: 20.0 °C)
Lower temp alarm (- 5 to 45.0 °C: 15.0 °C)
Speed alarm (OFF, ON (Upper), ON (Lower))
Speed limit (0 to 80 kn: 0 kn)
Arrival alarm (OFF, ON)
XTE alarm (OFF, ON)
NAV alarm range (5 to 999 m: 10 m)
NAV start (No.1 to No.10)
NAV cancel (Yes, No)
WPT edit (No.1 to No.10)
WPT delete (No.1 to No.10)
Background color (OFF, White, Black)
NAV 1 (Normal (H), Zoom (H), Dual freq, Zoom (L), Normal (L))
NAV 2 (Normal (H), Zoom (H), Dual freq, Zoom (L), Normal (L))
Image swap (A|B, B|A)
Image recall (No.1 to No.10)
Image comment (No.1 to No.10)
Image delete (No.1 to No.10)
Image partition ( , )
Fish image (A|B, A| , |B)
EVENT key set (Store pos, Store image, Fishing hot spot)
F1 key set (
I
mage speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV 1, NAV 2, Image swap, Image recall, Sona-ton)
F2 key set (Image speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV 1, NAV 2, Image swap, Image recall, Sona-tone)
Operation guide (OFF, ON)
Sona-tone (OFF, ON)
Key lock
Freq select (L) (24.0 to 210.0 kHz : 42.0) (For CVS-128B)
Freq select (H) (24.0 to 210.0 kHz : 210.0) (For CVS-128B)
Power freq adj (100.0 to 130.0 : 107.0) (For CVS-128B)
6-3
B
Chapter 6 Table Attached
In out
Correct
Setting
Maintain
Adjust2
CVS-128/128B
Buzzer setting (OFF, ON)
Temp source: (InsideSensor, NMEA)
Speed source (InsideSensor, NMEA)
Baud rate (4800, 9600, 19200, 38400)
NMEA monitor (OFF, ON)
NMEA output data
(ON : DBT, DPT, TLL OFF : GGA, MTW, VHW, VTG, ZDA)
NMEA output data
(ON : None OFF : GLL, HDT, MWV, RMC)
Draft set (- 10.0 to 10.0 m: 0.0 m)
Sonic speed (Seawater, Freshwater)
Water temp (- 10.0 to 10.0 °C: 0.0 °C)
Boat speed (- 50.0 to 50.0 %: 0%)
Beam angle H (1 to 120: 17°)
Beam angle L (1 to 120: 50°)
Size adjust (1 to 10: 6)
Detect adjust f (1 to 6: 4)
Bubble (OFF, Weak, Strong)
Bubble time set (OFF, 1 to 10minutes: 5minutes)
Language (English, Japanese, etc)
Range&Speed unit (NM, kn, km, km/h)
Depth unit (m, fm, I.fm, ft)
Temperature unit (°C, °F)
Localtime offset (- 11.0 to 14.0: 0.0)
GPS select (Others, KODEN GPS)
GPS initialize (No, Yes)
Simulation (OFF, ON)
Slideshow (OFF, 15, 30)
Initialize (No, Yes)
System check
All WPTs: DLT (No, Yes)
All IMG DT: DLT (No, Yes)
Bottom start (0.0 to 20.0: 1.5)
Past image (OFF, ON) (For CVS-128B)
Inner-hull (No, Yes)
TD select (TDM-071, TDM-091D, Others TD) (For CVS-128B)
STC strength H (-10.0 to 10.0: 0.0)
STC depth H (2 to 1000: 40)
STC strength L (-10.0 to 10.0: 0.0)
STC depth L (2 to 1000: 40)
Color adjust (Red:90,Orange:78,Yellow:66,Green:53,Sea green:39,Light blue:25,
Marine blue:12)
Image speed adj (-10 to 10: 0)
Bottom limit (1.0 to 3.0: 1.0)
Sounding (10 to 800m: 200m(For CVS-128), 500m(For CVS-128B))
6-4
CVS-128/128B
6.2 Specification
0093112802-06
Chapter 6 Table Attached
6-5
Chapter 6 Table Attached CVS-128/128B
6-6
CVS-128/128B
6.3 Appearance
Chapter 6 Table Attached
0093112802-06 6-7
Chapter 6 Table Attached CVS-128/128B
Hole for installing
4-4mm screw
Dimension drawing of table installation
R2
5 (6
3/6
4)
240
(9 29/64)
220
(8 21/32)
Threading hole
224
Unit: mm (inch)
Dimension drawing of flush-mount installation