Heater Package Assembly WARNING DANGER

Heater Package Assembly WARNING DANGER
Standard Diagram
Black
38
14
Black
Brown
Brown
25
20
1
3
9
5
7
34
(4) Thermal
Cutoffs
Heat Strip #1
10kw
Limit Switch
7
2
4
13
1
40
L2
L1
23
Blue
T2 T1
1
L2
L1
230/208-60-1
Power Source
Line 1 to
Power Source
Line 2 to
Power Source
Ground
Red
32
Blue
12
32
Red
12
Red
Line 2 to
Power Source
A
T2 T1
30
208/230-60-1
L1
CKB
Circuit
Breaker 2
L1
L2
Ckt A
2
Circuit Breaker 1 2
Circuit
Breaker 3
Circuit
Breaker 2
Heat
Strip
4
Thermal
Cutoff
3
8
Thermal
Cutoff
7
2
L2
T2
L2
T2
Heater
Contactor #2
Circuit
Breaker 1
Circuit
Breaker 2
Circuit
Breaker 1
Heat
Strip
3
Ground
Limit Switch
6
Black
Red
Orange/Black
4
Emergency
Heat Relay
9
7
6
4
Emergency
Heat Relay
4
3
H. Contactor #2
1
Line 1
3
Line 2
Orange
1
Line 1
2 6
Thermal
Cutoff
1
Heater
Contactor #1
2
3
T1
Heat
Strip
Ground
11
6 Pin Plug for
Optional Heater Package
Thermal
Cutoff
5
Heat
Strip #2
6
Circuit
Breaker 3
31 Lug
10
Black/White
Red/Yellow
Heater
Contactor #2
L1
T1
L1
Terminal Block
L2
L1
L2
Ckt C
Circuit Breaker 3 36
Line 1 to
Power Source
9
B
Ladder Diagram
18
Heater Contactor #1
3
24
Brown
4
6
Black/White
Brown
7
37
Brown
Heater Package
Assembly
! DANGER
*ELECTRICAL SHOCK HAZARD
*DISCONNECT POWER BEFORE
SERVICING.
Brown
15
22
Black/White
Emergency
Heat Relay
Blue
8
Red
Red
6 Pin Plug for
Optional Heater
Package
H. Contactor #1
Line 2
6
4116-105 A
! WARNING
USE COPPER CONDUCTORS
ONLY SUITABLE FOR AT LEAST
75° C.
Heater Contactor #2
Heat Strip #2
10kw
Blue
21
34
Was this manual useful for you? yes no