Quantum PX500 PX502 tape auto loaders & libraries Quick Start Guide

Quantum PX500 PX502 tape auto loaders & libraries Quick Start Guide
Add to My manuals

Quantum PX502 is an automated storage and retrieval device that can hold up to 32 SDLT or 38 LTO cartridges, providing a flexible and scalable storage solution for demanding environments. With its compact 4U design, it fits easily into standard 19-inch racks, making it ideal for data centers and businesses with limited space.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Quantum PX502 Tape Library Quick Start Guide | Manualzz

PX502 Tape Library

Quick Start Guide

TABLE OF CONTENTS

Introduction .......................................1

Notational Conventions .................1

Choosing a Location ..........................2

Rack Space Requirements...............2

Environmental Conditions .............2

Preparing for the Installation ...........2

Providing Necessary Tools ..............2

Taking ESD Precautions ..................2

Unpacking the PX502 Tape Library ...2

Removing the Remaining Packing

Materials.............................................9

Installing the Library .........................3

Locating the Mounting Position ....3

Installing the Library ......................4

Initial Configuration .......................9

Multiple Library Stacks....................13

Introduction

The PX502 tape library is an automated storage and retrieval device consisting of up to two tape drives and up to 32 SDLT cartridges or 38 LTO tape cartridges (see

figure 1 ).

0

Notational Conventions

This instruction uses the following conventions:

0

N OTE : Notes emphasize important information related to the main topic.

C AUTION : Cautions indicate potential hazards to equipment and are included to prevent damage to equipment.

W ARNING : Warnings indicate potential hazards to personal safety and are included to prevent injury.

This document explains how to unpack the PX502 tape library and install it in a standard 19 in. rack. Once the library is unpacked and installed, set up the library using the instructions in the

PX500 Series

User’s Guide

PN 81-81290. This installation procedure will take approximately 4 hours to complete.

N OTE : It is recommended to review the entire document prior to beginning the installation.

Figure 1 PX502 Tape Library

PX502 Tape Library Quick Start Guide

Choosing a Location

When choosing an installation site for the PX502, consider the following requirements:

Rack Space Requirements

Environmental Conditions

0

Rack Space Requirements 0

Table 1 contains the rack requirements for the PX502 tape

library.

Table 1 Rack Requirements

Dimensions

Depth

Width

Height

Weight

Air Clearance

PX502

31 in (78.7 cm)

19 in (48.3 cm)

6.75 in (17 cm), 4U

52 lbs (23.6 kg)

Open 4 in (10 cm) behind unit for proper air flow

Environmental Conditions 0

The installation site must have the following environmental conditions:

• Humidity: 20%-80% non-condensing

• Temperature: 10°C-35°C (50°F-95°F)

• Altitude: -500 to 10,000 feet (-152 to 3048 meters)

These environmental conditions apply when the PX502 tape library is in operation.

N OTE : For additional specifications, refer to the

Quantum PX500 Series User’s Guide

(PN 81-

81290)

Preparing for the Installation

Before you begin the installation procedure in this section, make the following preparations as described in this section:

Providing Necessary Tools

Taking ESD Precautions

0

Providing Necessary Tools 0

Provide the following tools for unpacking and installing the

PX502 tape library:

• #1 PHILLIPS® screwdriver

• #2 PHILLIPS screwdriver

• #1 flat blade screwdriver

• Allen wrench (2.5mm and 3mm) included in accessory kit

• Antistatic wrist strap included in accessory kit

Taking ESD Precautions 0

Some components within the PX502 tape library contain static-sensitive parts. To avoid damaging these parts while performing installation procedures, always observe the following precautions:

• Keep the PX502 turned off during all installation procedures.

• Use an antistatic wrist strap (included in the accessory kit).

• Keep static-sensitive parts in their original shipping containers until ready for installation. Look for the ESD sticker to identify static sensitive parts.

• Avoid touching connectors and other components.

N OTE : Dry climates and cold-weather heating environments have lower relative humidity and are more likely to produce static electricity.

Unpacking the PX502 Tape Library

0

This section explains how to unpack the PX502 tape library and move it to its final installation location.

N OTE : Inspect the outer library packaging for damage. If there is any damage evident on the library packaging, do not continue with the installation and contact Quantum customer support.

2

PX502 Tape Library Quick Start Guide

By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site.

N OTE : Unpack the library as close to the installation location as possible.

Unpack and remove the following components from the packing materials (see

figure 2

):

1 Remove the accessories kit and set it aside.

W ARNING : At least two people are required to move the library chassis.

C AUTION : Lift the library chassis at the sides. Avoid putting the weight of the library chassis on the front bezel.

2 With the help of a second person, lift the library chassis up and out of the shipping carton.

3 Place the library on a table approximately waist high.

Figure 2 Unpacking the PX502

Accessory kit

4 Remove the antistatic sheet:

a Cut the tape strips securing the sheet.

b Fold the sheet down.

c With the help of a second person, lift the library up off of the antistatic sheet.

d Place the library on the table or desk next to the antistatic sheet.

e If this is a multiple library stack, refer to “Multiple

Library Stacks” on page 13 before proceeding.

The PX502 is ready to install.

Installing the Library

Installing a PX502 tape library in a rack consists of the following steps:

Locating the Mounting Position

Installing the Library

Initial Configuration

0

Locating the Mounting

Position 0

The PX502 tape library is designed to fit in a standard 19 inch wide rack.

It is important to the library installation to locate the hole

pattern in the rack rails (see figure 3 ). The library must be

installed at the beginning of the hole pattern. Refer to

table 2

for information on common rack hole types.

Foam

Lift point

PX502 tape library

Front bezel

Foam

3

PX502 Tape Library Quick Start Guide

Table 2 Rack Hole Types

Figure

Cage nut

Description

Square rack holes are the most common type of rack holes. They can accept either cage nuts which mount from the back of the rail or clip nuts which clip on from the side of the rack rail.

Clip nut

Clip nut

Through holes require clip nuts to accept mounting hardware.

Threaded holes require neither cage or clip nuts to accept mounting hardware.

N OTE : The rails within the rack have a hole pattern that repeats throughout the rail. X marks the screw positions. Install nut clips (included in the accessory kit) on the rails if necessary.

Figure 3 Rail Hole Pattern

Front panel screws mounting positions

4U

Back panel screws mounting positions

Front panel screws mounting positions

1U = 1.75 in

(44.45mm)

The marks above ( X ) indicate the location of mounting hardware on the rack rails. Ensure that any necessary mounting hardware is installed on the rack rails prior to installing the chassis.

Hole pattern

Top of rack

.312 in (7.92 mm)

.625 in (15.9 mm)

.625 in (15.9 mm)

.5 in (12.7 mm)

.625 in (15.9 mm)

.625 in (15.9 mm)

.5 in (12.7 mm)

W ARNING : If the rack is empty at the time of installation, do NOT install the PX502 tape library too high in the rack. The weight of the library may cause the rack to become “top heavy” and unstable if installed in the top of an empty rack. Begin installing the PX502 tape library from the bottom of the rack if more than one library is installed.

Installing the Library 0

Installing the PX502 tape library consists of the following steps :

N OTE : If this is an upgrade to an existing library system,

see “Multiple Library Stacks” on page 13.

Installing the Rack Mount Shelves

Installing the Library Chassis

Cabling the Library

4

PX502 Tape Library Quick Start Guide

Table 3 Library Mounting Hardware

Qty

16

Figure

8

Description

Allen head screws (M5 x 10) for shelf assembly

T- nuts (M5)

4 metric and 4 standard

2

Rail adapters (both metric and standard holes are included, 8 total adapters, see

figure 4

)

Right and left support shelves (left shown)

N

a Loosely attach the adjustable shelves (right and left)

OTE with 4 M5 x 10 Allen screws and T-nuts.

: T-Nuts must be oriented so they fit in the grooves of the shelves.

b Attach the appropriate rail adapter to the front and back of the rack mount shelves (right and left) with 4

M5 x 10 Allen screws (each rail adapter is marked with the specific hole type supported, either metric or standard). The rail adapters have arrows

indicating the proper orientation (see figure 4 ).

Figure 4 Rail Adapter Orientation

4 sets Front and back rail mounting hardware

(M5 x 12 allen screws and mounting plates)

Keep the arrow up for correct orientation

2 sets

2 sets

Back bracket hardware (M5 x 8 allen screws and mounting plate)

Back clamp hardware

(M5 x 10 and back clamp)

Installing the Rack Mount Shelves

1 Assemble the rack mount shelves by (see

figure 5

and

figure 6 ):

0

5

PX502 Tape Library Quick Start Guide

Figure 5 Assembling the Left-

Hand Rack Mount Shelf

Rail adapter

T-nuts

Allen screws

• 2 M4 x 12 Allen screw.

N OTE : The rack mount shelves must be installed on the inside rack rails.

Figure 7 Installing the Rack

Mount Shelves

Rail adapter

Allen screws

Le ft sh elf

Allen screws

FlexLink™ opening located towards the front for the left-hand shelf

Figure 6 Assembling the Right-

Hand Rack Mount Shelf

Allen screws Rail adapter

T-nuts

Allen screws

Mounting plate

Left shelf Right shelf

3 Once the rack mount shelves are secured to the rack, tighten the Allen screws securing the adjustable shelves together.

Installing the Library Chassis

0

W ARNING : The PX502 tape library weighs approximately

52 lbs (23.6 kg). At least two people are required to lift and install the library.

1 The back mounting brackets are lettered (A through I) so the correct mounting position is easily determined.

The mounting positions differ depending on the depth of the rack (see

table 4 ).

Allen screws

Rig ht s helf

FlexLink opening located towards the back for the right-hand shelf

Allen screws Rail adapter

2 Install the left and right rack mount shelves into the rack (the rack mount shelves adjust 27 in. to 36 in.) and secure with the following parts in four locations (see

figure 7 ):

• Mounting plate

6

PX502 Tape Library Quick Start Guide

Table 4 Back Mounting Bracket

Orientation

Figure 8 Installing the Back

Mounting Brackets

Back mounting bracket

Rack Depth

> 27 to 28 in.

> 28 to 29 in.

> 29 to 30 in.

> 30 to 31 in.

> 31 to 32 in.

> 32 to 33 in.

> 33 to 34 in.

> 34 to 35 in.

> 35 to 36 in.

Mounting Position

Use holes A and C

Use holes B and D

Use holes A and C

Use holes B and D

Use holes C and E

Use holes D and F

Use holes E and G

Use holes F and H

Use holes G and I

Once the location is determined, attach the back brackets to each side of the library with four M5 x 8

Allen screws (see

figure 8

).

N OTE : Use the shortest depth number. For example, if the measurement is 34 in., use holes E and G.

Allen screws

Right-hand back bracket shown.

N OTE : If this is a multiple stack configuration, refer to

“Multiple Library Stacks” on page 13 for

information on preparing the library chassis for passing tape cartridges from one unit to another.

2 Install the library into the rack as shown in figure 9

and secure the library to the rack with four PHILLIPS screws.

W ARNING : The PX502 tape library weighs approximately

52 lbs (23.6 kg). At least two people are required to lift and install the library.

Figure 9 Installing the PX502 in the Rack

PHILLIPS screws

7

PX502 Tape Library Quick Start Guide

3 Secure the back of the library to the rack with two mounting clamps and two Allen screws on each clamp.

The mounting clamps are oriented differently

depending on the depth of the rack (see figure 10 ).

N OTE : If the rack depth is 27 to 30 in., the long portion of the clamp is mounted to the back. If the rack depth is 30 to 36 in., the long portion is mounted to the front.

4 Secure the mounting clamps to the rack rails with two

PHILLIPS screws on each side (see figure 10 ).

Figure 10 Securing the Back of the Library

b Insert the tape drive(s) into the drive bay(s) slowly until the connectors are seated. Refer to

figure 12 for

drive bay numbering (see the

Quantum PX500 Series

Tape Drive Installation Instructions

PN 81-81301 for information).

Figure 12 Installing the Tape

Drives

Long portion

Right-hand back bracket shown.

Allen screws

5 To install the tape drives into the library:

a Remove the tape drive cover plates (if necessary, some libraries ship with one tape drive installed) by loosening the captive screws securing the plate to

the library chassis (see figure 11 ).

Figure 11 Removing the Tape

Drive Cover Plates

Tape drive bay 1

Back of Library

Tape drive 2

Tape drive 1

c Tighten the tape drive thumbscrews using a flat blade screwdriver.

d Repeat these steps to install another tape drive in a different location, if desired.

The library chassis is installed in the rack.

Cabling the Library

1 Connect the SCSI cables and jumpers as shown in the following figures:

0

Figure 13 SCSI System Controller Board

Figure 14 Surrogate SCSI System Controller Board

Figure 15 Native Fibre Channel System Controller

Board

N OTE : Quantum ships sufficient SCSI cables and terminators with the libraries to set up two-drives per SCSI bus. One tape drive per SCSI bus may be necessary for optimum performance. Refer to your tape drive documentation.

N OTE : SCSI cable lengths should not exceed:

• 39.37 feet (12 meters) between the host and the library for single drive per bus installations.

Tape drive bay 2 Cover plate

8

PX502 Tape Library Quick Start Guide

Figure 13 PX502 Cable

Configuration (SCSI System

Controller Board)

Ethernet SCSI host SCSI System Controller Board

Tape drive 2 Tape drive 1

Power

Figure 14 PX502 Cable

Configuration (Surrogate)

Ethernet Surrogate System

Controller Board

Back of Library

SCSI host

Initial Configuration 0

Initially configuring the library consists of the following steps:

Turning on the Library

Removing the Remaining Packing Materials

Setting the Library Options

Setting the Date and Time

Setting Network Information

Turning on the Library

To turn on the library:

0

1 Verify that:

• Power cables are firmly in place

• All doors are closed and latched

2 Turn on the library by pushing power button located on

the bottom left-hand corner of the OCP (see figure 16 ).

Figure 16 Turning on the Library

Tape drive 2 Tape drive 1

Power Back of Library

N OTE : When operating in surrogate mode, the SCSI host connection must be made to tape drive 1.

Figure 15 PX502 Cable

Configuration (Native Fibre

Channel)

Ethernet Fibre Channel host/SAN

Tape drive 2 Tape drive 1

OCP

Power Tape Drive Fibre

Channel host ports

Back of Library

2 Connect one end of an AC power cable to each installed power supply and to a wall outlet.

Power button

The power up sequence can take several minutes. The first message displaying will be “Are the internal packaging materials removed?” Continue with

Removing the Remaining Packing Materials

Removing the Remaining Packing Materials

0

Now that you have installed the library chassis and powered on the system, you MUST remove the remaining packing materials from the library chassis before the library is operational.

9

PX502 Tape Library Quick Start Guide

1 Put on an antistatic wrist strap and clip it to the library chassis.

C AUTION : Take standard ESD precautions when performing this procedure.

2 IF there is space above the library to remove the top cover, remove the twelve PHILLIPS screws securing the top cover and FlexLink cover to gain further access to

the internal packaging restraints (see figure 17

). If there is no space above the PX502 library to remove the top cover, continue with Step 3.

Figure 17 Removing the Top

Cover (Optional Step)

4 Press NO to continue. The system asks you again: “Are the internal packaging materials removed?” (OK or

NO).

C AUTION : Pressing OK when the internal packaging restraints are in place will damage the library robotics.

5 Press NO to continue. The OCP displays “Doors opened, magazines released, pull magazines out before power shutoff. The library waits approximately 30 seconds for you to open the doors and remove both magazines from the library.

N OTE : If you are unable to remove the magazines before the library shuts down. Turn on the library power and repeat the steps above.

6 After the library has powered down, remove the foam restraints by completing the following steps (see

figure 18

):

a Detach the tie band holding the two sides of the metal restraints together and remove it from the library.

b Remove the metal restraints from the library.

c Lift the left foam restraint slightly up and remove it from the library.

d Slide the right foam restraint to the right until you are clear of the robotics motor and remove the restraint from the library.

C AUTION : Avoid touching the printed circuit board.

C AUTION : When removing the foam restraints, ensure that the robotics umbilical cable is lying down in the correct position and not across the robotics track.

3 When the library powers on for the first time, the OCP asks you: “Are the internal packaging materials removed?” (OK or NO).

10

PX502 Tape Library Quick Start Guide

Figure 18 Removing the Foam

Restraints

Tie band

Setting the Library Options

To set the library options:

0

1 Turn on the library by pushing power button located on

the bottom left-hand corner of the OCP (see figure 16 ).

2 The OCP asks you: “Are the internal packaging materials removed?” (OK or NO).

3 Press OK to continue.

4 The OCP asks again: “Are the internal packaging materials removed?” (OK or NO).

5 Press OK to continue. The library continues the boot process. When complete, the Home screen displays.

6 Press Setup from the Home screen. The OCP displays

the Setup screen (see figure 19

):

Figure 19 Setup Screen

Metal restraint

Foam restraints

Robotics umbilical cable

Metal restraint

N OTE : Save the robotics restraints and re-usable tie wrap for later shipping or relocation of the library.

e Install the tape cartridge magazines.

N OTE : Refer to the

PX500 Series User’s Guide

(PN 81-

81290) for more information on loading the tape cartridge magazines.

f Close the front doors.

g If you have removed the top cover for better access, install the top cover back on the library.

Enter

7 From the Setup screen, use the up and down arrows to highlight Cabinet and press Enter.

The Cabinet screen displays (see

figure 20 ):

Figure 20 Library Options Screen

8 The Stack role screen allows you to configure the library as a “Master” or “Slave” in a multiple library stack. The library is configured “Solo” by default. If this is a multiple library stack, use the up and down arrows to highlight Stack role and press Enter displays the following information about the library:

11

PX502 Tape Library Quick Start Guide

Table 5 Setting Up the Cabinet

Cabinet Options

Host bus

Stack role

Left load port

Right load port

Drive FUP from tape

Description

Sets the SCSI ID for both the library and tape drives.

Assigns the library stack role as Master, Slave, or Stand alone (solo). There can be only one Master library in a multiple stack. Once configured as a slave, all library OCP functions can be controlled via the Master library OCP. The library model number will also change to

PX500S indicating a stacked library configuration. The library model number is available from the home screen on the Master library

OCP.

Enables or disables the left load port

Enables or disables the right load port

Allows you to perform a tape drive firmware update from a firmware update tape cartridge.

Setting the Date and Time

To set the date and time:

0

1 From the Setup screen, use the up and down arrows to highlight Date and Time and press Enter.

The Date and Time screen displays (see

figure 21 ):

Figure 21 Date and Time Screen

2 Use the up and down arrows to view or edit the date and time information. Press Enter to accept the new settings.

3 When you are finished viewing/editing the date and time information, press Exit to return to the Setup screen.

Setting Network Information

To view or edit the network information:

0

N OTE : The library must be offline to change these settings.

1 From the Setup screen, use the up and down arrows to highlight Network and press Enter.

The Network screen displays (see figure 22 ):

Figure 22 Network Screen

The Network screen allows you to view or edit the following network settings:

• DHCP (default setting)

• IP address

• Subnet mask

• Default gateway

2 Use the up and down arrows to select the network setting you wish to view or edit and press Enter.

When you are finished viewing/editing the network information, press Back to return to the Setup screen.

3 For the network information such as the IP address to be active, you must reboot the library by holding down the power button located on the front of the library

(see

figure 16

).

The library shuts down.

4 Push the power button to start the library.

The PX502 tape library is initially configured and ready for use.

The Date and Time screen displays the following information about the library:

12

PX502 Tape Library Quick Start Guide

Multiple Library Stacks

0

N OTE : If the library is NOT being installed with other libraries to operate in a multiple library stack, it is not necessary to complete the following instructions.

If the library will be installed in a rack with other PX500

Series libraries, you must prepare each chassis prior to installation. Preparing the library chassis for installation into a multiple library stack consists of:

N OTE : It is recommended to place the Master library in the middle of the library stack for improved performance.

• Removing the FlexLink cover plates

• Installing the alignment hardware

To prepare the library chassis for multiple stack operation:

1 Remove two PHILLIPS screws securing each FlexLink cover located on the top and bottom of the library

using a #1 PHILLIPS screwdriver (see figure 23

).

N OTE : Remove the bottom FlexLink cover on every library except the bottom library in the stack. Remove the top FlexLink cover on the bottom library in the stack.

Figure 23 Removing the FlexLink

Cover

Remove only the top

FlexLink cover on the bottom library in the stack

Screws

To p

FlexLink cover

FlexLink cover

Bo tto m

Screws

Remove only the bottom FlexLink cover on the top library in the stack

2 The alignment hardware installed on the top and bottom of the libraries in a multiple stack allow the

FlexLink bays to align correctly when installed in a rack.

Install the following alignment hardware (see

figure 24

):

a Install the top alignment hardware with two Allen head screws.

b Install the bottom alignment hardware with one

Allen head screw.

N OTE : Install only the bottom alignment hardware on the top library in the stack and the top alignment hardware on the bottom library in the stack.

13

PX502 Tape Library Quick Start Guide

Figure 24 Installing the

Alignment Hardware

Top alignment hardware

Screws

To p

Bo tto m

Screws

Bottom alignment hardware

The libraries are prepared for installation in a multiple stack.

United States of America

Quantum Corporation

141 Innovation Drive

Irvine, CA 92612

U.S.A.

phone 949.856.7800

fax 949.856.7799

European Headquarters

Quantum Corporaton

3 Bracknell Beeches

Old Bracknell Lane West

Bracknell

Berkshire RG12 7BW

United Kingdom phone +44 1344 353500 fax +44 1344 353510

Asia Pacific

Quantum Corporaton

Level 3

200 Creek Street

Brisbane, Qld 4000

Australia phone +61 7 3839 0950 fax +61 7 3839 0955

©2006 Quantum Corporation. Quantum, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation. SDLT and Super DLTtape are trademarks of

Quantum Corporation. Other trademarks may be mentioned herein which belong to other companies.

81-81292-02 A01 January 2006

advertisement

Key Features

  • Automated storage and retrieval
  • Up to 32 SDLT cartridges or 38 LTO tape cartridges
  • Fits in a standard 19-inch rack
  • Date and time setting
  • Network information setting
  • Stackable for multiple library configuration
  • FlexLink bay alignment hardware
  • Easy to install
  • Power-up sequence
  • SCSI and Fibre Channel connectivity

Frequently Answers and Questions

How do I connect the PX502 library to the SCSI host?
Refer to the cable configuration diagrams in the documentation for the specific system controller board (SCSI, Surrogate, or Native Fibre Channel) you are using.
What are the environmental requirements for the PX502 library?
The library requires a temperature range of 10°C to 35°C (50°F to 95°F), humidity of 20% to 80% non-condensing, and altitude of -500 to 10,000 feet (-152 to 3048 meters).
How do I remove internal packaging restraints from the PX502 library?
Follow the instructions in the document to remove the packing materials carefully to prevent damage to the library robotics.
How do I set up a multiple library stack configuration?
Follow the procedures outlined in the document to prepare each library chassis for multiple stack operation by removing FlexLink cover plates, installing alignment hardware, and setting up the Stack role on the OCP.
What are the steps to install the tape drives in the PX502 library?
Loosen the captive screws securing the cover plate, insert the tape drive into the drive bay until the connectors are seated, and tighten the thumbscrews.