Crestron | CP3 | SYMETRIX SOLUTIONS: TECH TIP

SYMETRIX SOLUTIONS: TECH TIP
December 2014
Crestron VoIP and ATI Modules
This Tech Tip has been created to assist the set-up and implementation of
Crestron control modules for the SymNet 2 Line VoIP Interface Card and
SymNet 2 Line Analog Telephone Interface Card using SymNet Composer.
These modules have been prebuilt and configured to work in conjunction with
the provided SymNet Composer example file. These modules have been
tested and verified by Symetrix. Functionality is guaranteed unless modified.
Please contact Crestron for support after modification.
This Tech Tip provides information based on the Crestron VoIP and ATI
Module Suites that can be downloaded here. The set-up procedures are the
same for both.
Symetrix Software
• SymNet Composer 3.0 or higher
Crestron Software
• Toolbox
• SIMPL Windows
• VisionTools Pro-e
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
Set-up Process
1. Open Toolbox and discover CP3 device. Make note of IP address (example 192.168.100.65)
SYMETRIX SOLUTIONS: TECH TIP
December 2014
2. Open Vision Tools Pro-e
4. Open VTPro-e project: File>Open>Project (example file labeled Symetrix VOIP Demo r2.13 Beta)
3. Make sure “Property Grid” opens. If not, click on “Options” and select “Property Grid”
5. In the Property Grid window go to “Connection Setting”. Set the Host IP address to the IP address discovered for the CP3 (example 192.168.100.65)
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
SYMETRIX SOLUTIONS: TECH TIP
December 2014
6. Set the IPID to 03 and Port to 41794
8. Go to File>Compile Project…
9. Open SIMPL Windows
7. Go to File>Save Project
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
SYMETRIX SOLUTIONS: TECH TIP
December 2014
10. Open SIMPL Windows file. Go to File>Open (example file named Symetrix CP3 VOIP Demo v2.13 Beta)
11. In the “Program View” window, expand “Central Control Modules : CP3”
12. Expand “Slot-02 : CP3 Ethernet”
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
SYMETRIX SOLUTIONS: TECH TIP
December 2014
13. Right-click “IP-ID-04 : TCP/IP_Client” and select “Configure Device”
14. In the “Device Settings: Crestron TCP/IP Client” window select the “IP Net
Address” tab
15. Set the default address to the IP address of the Symetrix DSP
16. Click “OK”
17. Go to Project>Convert/Compile
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
SYMETRIX SOLUTIONS: TECH TIP
December 2014
18. Click “Yes” to Transfer File
19. In Address Book window make sure Connection Type is TCP and IP Address / Hostname are set to the IP address of the CP3
20. Click “OK”
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
24. Make sure Internal Flash is selected then click “Send”
SYMETRIX SOLUTIONS: TECH TIP
December 2014
25. Click “Yes” to continue
27. Load SymNet Composer Example file
28. Locate and go online with Symetrix DSP
26. After programming has been sent, click “Close”
29. Open Crestron XPanel file
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
SYMETRIX SOLUTIONS: TECH TIP
December 2014
Crestron Module Functions
The Crestron Modules are programmed with five different tabs. Each tab
controls different functions. The examples below show the corresponding
modules inside SymNet Composer that the Crestron is controlling.
#1: Contains Master and Program Volume and Mute, Record and Mic 1 Mute, also Front and Ceiling Speakers On/Off.
Notice: Controller ID is labeled, use Remote Control Manager in SymNet Composer to
find the corresponding module that is being controlled by the Crestron.
30. Go to Options>Host Settings
31. Make sure Hostname/IP Address is the same IP address as the Crestron CP3 (example 192.138.100.65), then make sure IPID is set to 03 and Port is 41794. Click “Connect”
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
SYMETRIX SOLUTIONS: TECH TIP
December 2014
#2: Contains VTC, VoIP Line 1 and VoIP Line 2 Volume and Mute.
Notice: Controller ID is labeled, use Remote Control Manager in SymNet Composer to
find the corresponding module that is being controlled by the Crestron.
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
#3, #4 and #5: Dialer functions for VoIP Line 1 and VoIP Line 2.
Note: Control numbers are already assigned to VoIP Interface. Line needs to be
registered for module to function properly.
SYMETRIX SOLUTIONS: TECH TIP
December 2014
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co