AMP SERIES INSTALLATION AND OPERATION MANUAL CONSTANT VOLTAGE INSTALLATION AM42P

Add to my manuals
16 Pages

advertisement

AMP SERIES INSTALLATION AND OPERATION MANUAL CONSTANT VOLTAGE INSTALLATION AM42P | Manualzz

INSTALLATION AND OPERATION MANUAL

AMP SERIES

CONSTANT VOLTAGE INSTALLATION

AUDIO POWER AMPLIFIERS

AM42P

AM41P

AM22P

AM21P

IMPORTANT SAFETY INFORMATION PRÉCAUTIONS DURANT UTILISATION

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.

14. Refer all servicing to qualified service personnel.

Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15. This appliance shall not be exposed to dripping or splashing water and that no object filled with liquid such as vases shall be placed on the apparatus.

16. Plug this apparatus to the proper wall outlet and make the plug to be disconnected readily operable.

17. Mains plug is used as disconnected device and it should remain readily operable during intended use. In order to disconnect the apparatus from the mains completely, the mains plug should be disconnected from the mains socket outlet completely.

18. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

19. An appliance with a protective earth terminal should be connected to a mains outlet with a protective earth connection.

20. The apparatus should be disconnected from the mains completely before speaker wiring. The speaker output should be proper protected from direct contact and pay attention to speaker connections, terminals and speaker wiring during normal operation.

1. LISEZ ces instructions.

2. Tenez ces instructions.

3. Notez tous les avertissements.

4. Suivez toutes les avertissements.

5. N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.).

6. Nettoyez seulement avec une étoffe sèche.

7. Ne bloquez aucuns troux de ventilation. Installez en accord avec les instructions du manufacturier.

8. N’installez près aucunes sources de chaleur comme radiateurs, registres de chaleur, fours ou les autres équipements (y compris amplificateurs) qui produisent la chaleur.

9. Ne défaites pas le but de sécurité de la fiche polarisée ou base-type. Une fiche polarisée a deux tranchants avec un plus large que l’autre. Une fiche de base type a deux a deux tranchants et une troisième pointe de base, le tranchant large ou la troisième pointe est fourni pour votre sécurité. Si la fiche donnée ne conforme pas votre prise de contact, consultez un

électricien pour remplacement de la prise de contact obsolète.

10. Protegez le cordon de secteur contre être marchée dessus ou pincez en particulier aux fiches, aux douilles de convenance, et au point où ils sortent de l’appareil.

11. Seulement utilisez attachements/accessoires spécifiés par le manufacturier.

12. Utilisez seulement avec un chariot, un stand, un trépied, un support ou une table indiquée par le manufacturier, ou vendue avec l’appareil. Quand un chariot est utilisé, faites attention en déplaçant la combinaison d’appareil/chariot pour éviter de se déséquilibrer.

13. Arrachez la fiche du dispositif durant éclair et orage ou quand pas utilisé pour longues périodes de temps.

14. Référez au personnel qualifié de service pour toutes réparations. La réparation est donnée quand le système a été endommagé à n’importe façon, par exemple un fil ou une fiche endommagé(e) de la source d’alimentation.

Avoir été exposé à pluie ou humidité, n’opère pas normalement, ou avoir été tombé.

15. L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures et aucun objet ne contenant de liquide, tel qu’un vase, ne doit être placé sur l’objet.

16. Branchez l’appareil à une source appropriée et faire que la prise à débrancher soit facilement accessible.

17. La prise du secteur ne doit pas être obstruée ou doit être facilement accessible pendant son utilisation. Pour être complètement déconnecté de l’alimentation d’entrée, la prise doit être débranchée du secteur.

18. AVERTISSEMENT: Pour éviter le risque d’incendie ou de chocs électriques, ne pas exposer cet appareil à la pluie ou à l’humidité.

19. Un appareil avec la borne de terre de protection doit être connecté au secteur avec la connexiion de terre de protection.

20. Assurez-vous que l’appareil est hors tension avant de connecter les hauts parleurs. Verifiez que la sortie des enceintes soit protégées contre un contact physique. Respecter les polarités des terminaux ainsi que le câblage des enceintes pendant le fonctionnement afin d’assurer une utilisation sécurisee.

PAGE 2 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

INTRODUCTION AND CONTENTS

AMP SERIES

Congratulations on choosing Australian Monitor for your professional amplification requirements.

The design of our AMP constant voltage installation series audio power amplifiers embraces all the aspects of a well designed amplifier.

The visual design, mechanical, electrical and sonic parameters, along with our dedicated manufacturing process, have all been optimized to provide a professional tool that exhibits quality, reliability and longevity.

The AMP series amplifiers are 1 unit 1.75” high, 19” wide, rack mountable units.

Each channel of the amplifier comprises a balanced active input, level potentiometer, voltage controlled attenuator and fan-cooled class D output stage. The amplifier operates from a power factor corrected switch mode power supply.

These amplifiers have been specifically designed to deliver their high power output with minimal distortion, and provide the critical degree of control required by your speakers.

INTRODUCTION 3

FEATURES & PROTECTION FEATURES 4

CONTROLS, CONNECTORS & INDICATORS 5

INSTALLATION 8

OPERATION 10

MAINTENANCE 11

SPECIFICATIONS 12

Revision 1.0: Nov 2014

WARNING!

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH

AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES

CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE

THIS APPLIANCE TO RAIN OR MOISTURE.

TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT & FULLY INSERT.

CAUTION

THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY.

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT

CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING:

TO REDUCE THE RISK OF

ELECTRIC SHOCK, DO NOT

REMOVE COVER (OR BACK).NO

USER SERVICEABLE PARTS

INSIDE. REFER SERVICING TO

QUALIFIED SERVICE

PERSONNEL.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

For European Union countries: This symbol on the product or its packaging indicates that this product must not be disposed of with other waste.

Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.

Please contact your local authority for further details of your nearest designated collection point.

Rating plate and caution marking are marked on the back enclosure of the apparatus

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL PAGE 3

FEATURES & PROTECTION FEATURES

FEATURES

Class-D amplification

4Ω/70V/100V Operation

Balanced inputs

Output Limiter

Ground Lift

Bridge mode

Voltage controlled attenuation (VCA)

Protect/Clip and Signal LED indicators

Power factor corrected universal switch mode power supply

Efficient front to back cooling

Dual, twin speed axial fans.

6 pin output screw terminal per channel

Custom designed, 1RU heavy-duty steel chassis

Front rack mount ears

Symmetrical layout – even weight distribution

PROTECTION FEATURES

Short-circuit protection

Suppression of inrush current at mains turn-on

Internal, independent DC supply rail fuses

Radio-frequency interference suppression

Amplifier Block Diagram

PAGE 4 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

2

CONTROLS, CONNECTORS & INDICATORS

3 4 1

5 6

FRONT PANEL

The AMP Series differ only slightly across all models and all share the same features on their front panels.

The functions of the controls and indicators are as follows:

1

Power Switch

Press the switch to up for power on and down for power off. At start-up

(turn-on), the input to the amplifier is muted for approximately two seconds.

2

Power Indicator

This blue LED will illuminate and indicates that the amplifier is on and receiving mains power.

3

Protect Indicator

This yellow LED indicates a problem with the amplifier or that it has over heated. In the advent of a thermal overload, the internal operating temperature of one or both amplifier channels has exceeded a safe level of operation and the channel will be automatically muted. The fans will continue to run and once the effected channel/s have cooled, they will unmute and return to normal operation.

The AMP series is also fitted with DC protection, if there is a DC voltage at the output the protection LED will glow yellow.

It should be noted that the minimum load for the amplifier is 4 ohms per channel (8 ohms bridged).

If an overload occurs, the amplifier will run into a current limit mode, restricting the excess current beyond set limits.

4

Clip Indicator

This red LED will illuminate when clipping occurs. Clipping can occur under extreme operating conditions such as:

• complex or very low loads

• over driving the amplifier

NOTE: The amplifier is not damaged by running into clipping, but speakers may be. To maximise the life of your speakers, try to keep clipping infrequent.

5

Signal Indicator

This green LED will illuminate when an input signal is detected.

6

Fan Grill

This is where air is drawn into the amplifier for cooling.

NOTE: You should always ensure that the fan grille is kept clean and the foam is free from dust or lint. This will ensure longer operation of your amplifier and reduce the possibility of it prematurely going into thermal shutdown mode. Refer to the “Maintenance” section on page 11 for further information.

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL PAGE 5

CONTROLS, CONNECTORS & INDICATORS

7

8

9

10

TOP PANEL

The switches on the top panel are accessed through a vent opening. Use a small rod through the vents to move the switches to the desired positions.

NOTE: Only make changes to these switches when the unit is powered off.

7

Bridge / Stereo

Turn the bridge switch on to enable BRIDGED mode. In this mode your amplifier will only accept signal applied to channel 1’s balanced input. The level is controlled by the channel 1 level potentiometer and/or VCA attenuator.

The output from channel 2 will automatically be of the opposite polarity

(reversed phase) and speaker termination should be sourced from the 4Ω output of each channel respectively. (see Speaker Connector Wiring Diagram)

8

Limiter Switch

Turn the limiter switch on to engage the clip limiter circuitry. The threshold level is referenced to the supply rail and the output voltage is sampled allowing true clip detection and limiting.

9

VCA Switch

Turn the VCA switch on to engage the voltage controlled attenuation input.

10

Signal Ground Lift Switch

When this switch is engaged it disconnects signal ground from the respective input channel.

It is intended to be used when “hum” is caused by earth loops (due to different ground potentials between source equipment and the amplifier) or stray magnetic field pick up on the input ground/shield wiring. (It does not interrupt signal ground continuity on the strapping connector). The amplifier should be turned off before engaging this switch!

PAGE 6 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

CONTROLS, CONNECTORS & INDICATORS

4 1

REAR PANEL

1

Mains Input Connector

Your amplifier is fitted with a standard IEC 60320-C14 socket for mains connection. Use the mains cable supplied to power up the unit.

NOTE: Your unit must always be earthed!

2

Signal Input

A balanced male 3-pin (3.81mm) Phoenix type connector is provided on each input:

Pin 1 = Hot (non-inverting or in phase)

Pin 2 = Cold (inverting or reverse phase)

Pin 3 = Signal Ground

5 3 2

3

Level Control

A potentiometer to provide attenuation to the signal input.

4

VCA Control

Connect an Australian Monitor RC1 remote panel or any 500kΩ potentiometer between the + and – terminals of the VCA input for external level control.

5

Speaker Outputs

The output for each channel can be 100V Line, 70V Line or 4 Ohm low impedance. Only one output type should be used per channel.

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL PAGE 7

INSTALLATION

Power Requirements

Power consumption for your model of the AMP Series amplifier is indicated on the rear panel for 1/8th output power.

Ensure that your mains voltage is the same as the rear panel mains voltage marker (+/- 10%).

Mounting

The AMP series amplifiers are one rack units high (1U) and will fit a standard

EIA 19” rack. A rack rear support bracket is supplied and must be installed when rack mounting the amplifier. The rear support bracket should be installed to the rack (rear rails) prior to mounting the amplifier. Failure to mount or support the amplifier correctly may lead to chassis damage which is not covered by warranty.

Typically amplifiers may be stacked directly on top of each other with no need for spacing between units, unless installed in high ambient temperature environments were a single rack unit space between amplifiers will assist cooling further.

Cooling

Your AMP Series amplifier is cooled by axial fans which draw cool air from the front of the amplifier and expels the heated air out the rear of the amplifier.

These amplifiers offer variable speed fans which run at half speed up to full speed when the internal heatsink temperature exceeds 60° C (128° F).

An unrestricted airflow into and out from the amplifier must be provided. Any restriction of the air flow will cause heat to build up within the unit and possibly force the unit into its thermal shutdown mode.

If the amplifiers are to be operated in an environment where the airflow is restricted such as sealed racks, the cooling should be supplemented by extra cooling fans to evacuate the heated air and aid the flow of cool air through the unit.

Input Wiring

IMPORTANT: Do not directly connect pin 3 on the amplifier’s input to the amplifier’s chassis, speaker ground or power ground!

WARNING: Input signal ground is not to be used as a safety ground (earth).

The input to your amplifier is a balanced 3-pin configuration and requires all three pins to be connected. Only high quality twin-core shielded cable should be used.

Pin 1 = HOT (In Phase - non inverting).

Pin 2 = COLD (Reverse Phase - inverting).

Pin 3 = GROUND / SHIELD.

When wiring from an unbalanced source you must ensure that pin 2 is connected to pin 3 (input ground), either by linking the pins in the input connector or by the source equipment’s output wiring.

When wiring for an unbalanced source:

Pin 1 = HOT (in phase with the amplifier’s output)

Pin 2 = GROUND/SHIELD (joins to pin 3).

Pin 3 = GROUND/SHIELD

Output Wiring

When wiring to your speakers always use the largest gauge wire your connector will accept. The longer the speaker lead, the greater the losses will be, resulting in reduced power and less damping at the load. We recommend using a heavy duty, two core flex (four core flex if bi-amping) 10 to 12 gauge (2mm2 to

2.5mm2 or 50/0.25 or equivalent) as a minimum.

Speaker Outputs

Each channel has a 6 pin output screw terminal with a pre-fitted link between the 4Ohm and high voltage line transformer.

IMPORTANT: Ensure the link is fitted if you are using the 70V or

100V output.

PAGE 8 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

Speaker Connector Wiring Diagram

Connect the speaker/s based on your required operating mode as shown in the diagrams below

4/8 Ohm 70V

INSTALLATION

100V

Hum Problems

Most equipment is designed for minimum hum when used under ideal conditions. When connected to other equipment, and to a safety earth in an electrically noisy environment, problems may occur.

The three ”E”s of hum and hum related noise which can plague your audio system are: a) Electrostatic radiation, b) Electromagnetic radiation, and c) Earth loops

Electrostatic radiation capacitively couples to system elements, causing an inter- ference voltage that mainly affects higher impedance paths, such as amplifier inputs. The source is generally a nearby high voltage, such as a mains lead or a speaker lead. The problem can usually be reduced by moving the offending lead away, or by providing additional electrostatic shielding (i.e. an earthed conductor which forms a barrier to the field).

Electromagnetic radiation induces interference currents into system elements that mainly effect lower impedance paths. Radio transmitters or stray magnetic fields from mains transformers are often the cause of this problem. It is generally more difficult to eliminate this kind of interference, but again, moving the source away or providing a magnetic shield (i.e. a steel shield) should help.

Earth loops can arise from the interfacing of the various pieces of equipment and their connections to various safety earths.

This is by far the most common cause of hum, and it occurs when source equipment and the amplifier are plugged into different points along the safety earth where the safety earth wiring has a current flowing through it. The current flowing through the wire produces a voltage drop due to the wire’s resistance.

This voltage difference between the amp earth and source equipment earth appears to the amplifier’s input as a signal and is amplified as hum. There are three things you can do to avoid earth loop problems:

Ensure the mains power for the audio system is “quiet” i.e. without equipment on it such as air-conditioning, refrigeration or lighting which may generate noise in the earth circuit.

Ensure all equipment within the system shares a common ground/ safety earth point. This will reduce the possibility of circulating earth currents, as the equipment will be referenced to the same ground potential.

Ensure that balanced signal leads connecting to the amplifier are connected to earth at one end only.

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL PAGE 9

OPERATION

IMPORTANT: All signal source equipment should be adequately earthed. This not only ensures your safety but everybody else’s as well.

Faults can and do occur in mains connected equipment where the chassis can become “live” if it is not properly earthed. In these instances, the fault in a “floating” (ungrounded) piece of equipment will look for the shortest path to ground, which could possibly be your amplifier’s input.

If the fault current is large enough, it will destroy the input to your amplifier and look for the next available path, which may be you!

Before making any connections to your AMP Series amplifier, observe the following:

Ensure the mains voltage supply matches the label on the rear panel of your amplifier (+/- 10%).

• Ensure that the power switch is OFF.

• Ensure that all system grounds (earth) are connected from a common point.

Avoid powering equipment within a system from multiple power sources that may be separated by large distances.

• Check the continuity of all interconnecting leads to your amplifier; ensure that there are no open or short circuited conductors.

Ensure that the power handling of your load (speakers) can adequately cope with the power output of the amplifier.

Before operating your AMP Series amplifier, ensure that:

• The BRIDGE Switch is not engaged if you are not running the amp in bridged mode.

Powering Up

REMEMBER: The amplifier should be the last piece of equipment that you turn on and the first piece of equipment that you turn off.

We recommend turning the attenuators on your amplifier down when turning the unit on.

Sensitivity

Your amplifier is a linear device operating with a fixed input to output voltage gain (less attenuation). The maximum output voltage swing is determined by the applied mains voltage, load, load type and the duty cycle of the applied signal.

The input sensitivity for your AMP Series amplifier when the level control is at maximum position (fully clockwise) and the VCA is disabled is nominally:

+2.2dBu (1.00 volts in) for rated power into a 4 Ohm load.

Each channel of your AMP Series amplifier has a nominal balanced input impedance of 30kOhms (@1kHz) and should not present a difficult load for any signal source.

Your signal source (i.e. the equipment feeding signal to the amplifier) should have an output impedance of 600 Ohms or lower to avoid unwanted high frequency loss in the cabling.

PAGE 10 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

MAINTENANCE

Maintenance

Only competent or qualified persons should attempt any service or maintenance of your amplifier. Your AMP Series amplifier will need minimal maintenance. No internal adjustments need to be made to the unit to maintain optimum performance. To provide years of unhindered operation we suggest a maintenance inspection be carried out on a regular basis, say every 12 months or so.

Fans

Due to the openness of the air path through your AMP Series amplifier, very little dust should settle within the amplifier. The unit has been designed so that any dust and/or foreign particles that do settle within the amplifier will not unduly hinder the cooling of the amplifier.

The grille in front of the fans will act to limit the amount of dust and lint entering the amplifier. You will find in time that there will be a build up of dust and lint on the grille which may start to hinder the airflow through the amplifier.

You should periodically remove the dust and keep the grille clean. Removal of dust from the rear grille will also aid cooling.

Over time, dust may build up on the leading edge of the fan blades and reduce their cooling efficiency. The time taken for this to happen will depend on the environment and the amount of use.

The fan blades are accessible once the lids are removed and can be easily cleaned. You need only hold the fan rotor still and wipe the dust off the blades.

Many users stall the fan and use compressed air to blow the dust off the fan blades. It is important to note that the fan blades must be held still whilst blowing air over the blades otherwise you may burn out the bearings in the fan.

Fuses

There are two rail fuses provided internally per amplifier channel. These rail fuses are in series with the positive and negative output supply and provide overall protection for the output stage. If the amplifier is subjected to heavy use such as short circuits, 1 Ohm or bridged 2 Ohm loads, these fuses will eventually fatigue and may require replacing to ensure they do not fail at an inconvenient time.

WARNING: Make sure the unit is off and is unplugged from the mains. Give the main filter capacitors time to discharge before removing lids and inspecting the fuses.

You should replace the fuse if the element is sagging or discoloured. Only ever replace with the same type fuse and current rating.

When checking for a failed fuse, do not rely on visual inspection alone. You should use an Ohm meter to check continuity

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL PAGE 11

SPECIFICATIONS

Model

Topology

Channels

Power Output (per channel)

Single Channel 4Ω

4Ω (All Driven)

Bridged 8Ω

Single Channel 100V

100V (All Driven)

Maximum Output Level

System Gain

Frequency Response 4Ω

Frequency Response 100V

Signal to Noise Ratio

THD+N. 4Ω, 8Ω. 1kHz

THD+N. 100V. 1kHz

AM21P

Class-D

2

120W

110W

230W

120W

110W

28.24dBu (20Vrms)

26dB

20Hz–25kHz

100Hz–16kHz

> 95 dBr

< 0.2%

< 0.3%

Channel Separation (crosstalk)

Damping Factor

Input Connectors

Input Impedance

Output Impedance

Input Sensitivity

Input CMRR

Output Connectors

LED Status

User Controls

> 65 dB (for < 1KHz)

> 60 dB (for > 1KHz)

> 90

Two 1x3 terminal plug

(3.81mm)

30kΩ

80mΩ

1.0 Vrms

> 55dB

6 pin Screw Terminal per channel

Signal, Clip, Protect

Gain, switches (Bridge,

Limiter, VCA, GND lift)

500kΩ VCA Attenuation (via potentiometer)

Limiter

AC Input

AC Power Factor

AC Connector

Maximum Inrush Current

Overload Protection

95W

100-240Vac, 50-60Hz

0.97

IEC 60320-C14

18.8A

Temperature, Over Voltage,

Current Limit

AM22P

Class-D

2

210W

200W

400W

210W

200W

31.25dBu (28.28Vrms)

29dB

20Hz–25kHz

100Hz–16kHz

> 95 dBr

< 0.2%

< 0.3%

> 65 dB (for < 1KHz)

> 60 dB (for > 1KHz)

> 90

Two 1x3 terminal plug

(3.81mm)

30kΩ

80mΩ

1.0 Vrms

> 55dB

6 pin Screw Terminal per channel

Signal, Clip, Protect

Gain, switches (Bridge,

Limiter, VCA, GND lift)

500kΩ

AM41P

Class-D

4

120W

110W

230W

120W

110W

28.24dBu (20Vrms)

26dB

20Hz–25kHz

100Hz–16kHz

> 95 dBr

< 0.2%

< 0.3%

> 65 dB (for < 1KHz)

> 60 dB (for > 1KHz)

> 90

Four 1x3 terminal plug

(3.81mm)

30kΩ

80mΩ

1.0 Vrms

> 55dB

6 pin Screw Terminal per channel

Signal, Clip, Protect

Gain, switches (Bridge,

Limiter, VCA, GND lift)

500kΩ

200W

100-240Vac, 50-60Hz

0.99

IEC 60320-C14

18.8A

Temperature, Over Voltage,

Current Limit

95W

100-240Vac, 50-60Hz

0.99

IEC 60320-C14

18.8A

Temperature, Over Voltage,

Current Limit

AM42P

Class-D

4

Conditions/Comments

210W

200W

400W

210W

200W

1kHz. 1%THD. -10W/+30W

1kHz. 1%THD. -10W/+30W

1kHz. 1%THD. -10W/+30W

1kHz. 1%THD. -10W/+30W

1kHz. 1%THD. -10W/+30W

31.25dBu (28.28Vrms) 20Hz–20kHz, <1%THD

29dB

20Hz–25kHz

100Hz–16kHz

3dB below clipping,

+0/-3dB.±5Hz

3dB below clipping,

+0/-3dB.±5Hz

> 95 dBr

< 0.2%

< 0.3%

> 65 dB (for < 1KHz)

> 60 dB (for > 1KHz)

> 90

Four 1x3 terminal plug

(3.81mm)

30kΩ

80mΩ

1.0 Vrms

Max Output, 1kHz, 20kHz BW,

A-Weighted

3dB below clipping,

1kHz. 20kHz BW, Unity Gain,

A-Weighted

3dB below clipping,

1kHz. 20kHz BW, Unity Gain,

A-Weighted

20Hz–20kHz, Max output,

Adjacent Channels

20Hz–1kHz, 8Ω. ±10

Balanced, line to line

> 55dB

6 pin Screw Terminal per channel

Signal, Clip, Protect

Gain, switches (Bridge,

Limiter, VCA, GND lift)

500kΩ

±0.2V. Level control at maximum

20Hz–20kHz

200W ±5W, 5%THD

100-240Vac, 50-60Hz ±10%

0.99

IEC 60320-C14

Max Output, 1kHz

31.83A

Temperature, Over Voltage,

Current Limit

264VAC, 53Hz

PAGE 12 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

SPECIFICATIONS (CONT)

Model

AC Mains Fuse

AC Internal Fuses, Power Supply

DC Amplifer Fuse

RMS Current Draw

Idle

1/8th Power

1/3 Power

Full Power

Power Consumption

Idle

1/8th Power

1/3 Power

Full Power

Efficiency

1/8th Power

1/3 Power

Full Power

Thermal Dissipation

Idle

1/8th Power

1/3 Power

Full Power

Dimensions

(W x D x H)

Shipping Dimensions

(W x D x H)

Net Weight

Shipping Weight

Mounting

Operating Temperature

Cooling system

Finish

Colour

Accessories

AM21P

T2.5AL 250V

T8AH 250V,

T3.15AL 250V

T5AL 250V

0.133A

0.262A

0.486A

1.15A

28W

58W

107W

264W

43%

62%

76.00%

AM22P

T5AL 250V

T8AH 250V,

T3.15AL 250V

T5AL 250V

0.176A

0.441A

0.862A

2.23A

38W

98W

196W

510W

51%

68%

71.00%

AM41P

T5AL 250V

T8AH 250V,

T3.15AL 250V

T5AL 250V

0.200A

0.472A

0.905A

2.27A

43W

100W

206W

522W

50%

65%

77.00%

AM42P

T10AL 250V

T8AH 250V,

T3.15AL 250V

T5AL 250V

0.371A

0.87A

1.73A

4.47A

72W

195W

392W

1030W

51%

68%

78.00%

Conditions/Comments

Time Lag, Low Breaking capacity

Time Lag, High Breaking capacity

Time Lag, Low Breaking capacity

Fast, Low Breaking capacity

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

230Vac, 50Hz. Bridged 8Ω

96

113

138

218

130

164

214

375

147

171

248

416

246

324

428

785

Excludes Load Power

(1W = 3.412BTU/Hr)

Excludes Load Power

(1W = 3.412BTU/Hr)

Excludes Load Power

(1W = 3.412BTU/Hr)

Excludes Load Power

(1W = 3.412BTU/Hr)

483mm x 448mm x 44mm

(19” x 17.63” x 1.73”)

483mm x 448mm x 44mm

(19” x 17.63” x 1.73”)

483mm x 448mm x 44mm

(19” x 17.63” x 1.73”)

483mm x 448mm x 44mm

(19” x 17.63” x 1.73”)

Not including rack ears

545mm x 515mm x 105mm

(21.46” x 20.28”x 4.13”)

545mm x 515mm x 105mm

(21.46” x 20.28”x 4.13”)

545mm x 515mm x 105mm

(21.46” x 20.28”x 4.13”)

545mm x 515mm x 105mm

(21.46” x 20.28”x 4.13”)

7.4 Kg (16.31 lbs) 7.8 Kg (17.20 lbs) 9.42 Kg (20.77 lbs) 11.3 Kg (24.91 lbs)

9.5Kg (20.94 lbs)

1 RU

0°C to 40°C (95% RH)

Fan assisted convection cooling

Powder coated steel/

ALU front panel

Black

IEC Mains cable.

Rubber Feet x 4,

Two 1x3 terminal socket,

Two 1x2 terminal socket,

Rack mount support

9.5Kg (20.94 lbs)

1 RU

0°C to 40°C (95% RH)

Fan assisted convection cooling

Powder coated steel/

ALU front panel

Black

IEC Mains cable.

Rubber Feet x 4,

Two 1x3 terminal socket,

Two 1x2 terminal socket,

Rack mount support

12.6Kg (27.78 lbs)

1 RU

0°C to 40°C (95% RH)

Fan assisted convection cooling

Powder coated steel/

ALU front panel

Black

IEC Mains cable.

Rubber Feet x 4,

Four 1x3 terminal socket,

Four 1x2 terminal socket,

Rack mount support

12.6Kg (27.78 lbs)

1 RU

0°C to 40°C (95% RH)

Fan assisted convection cooling

Powder coated steel/

ALU front panel

Black

IEC Mains cable.

Rubber Feet x 4,

Four 1x3 terminal socket,

Four 1x2 terminal socket,

Rack mount support

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL PAGE 13

NOTES

PAGE 14 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

NOTES

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL PAGE 15

ENGINEERED BY AUSTRALIAN MONITOR

Address: Level 7, 130 Pitt Street, Sydney NSW 2000 Australia.

Website: www.australianmonitor.com.au International enquiries email: [email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement