F700 Series
Variable Frequency Drives
Delivering Dependability When You Need it Most
F700TheVFD
New Energy Saving Inverter
Features
Parameter Change
The truly fantastic
specifications of the
F700 make this VFD
UL Type 1, Plenum Rated, Enclosure Designs (NEMA 1):
Drive can be mounted as a stand-alone unit.
BACnet MS/TP protocol built in: Support for other popular
BMS systems, including Metasys N2, Siemens FLN, and
LonWorks is available.
Built in PLC: Uses GX Developer for programming, 4K steps
of memory
Single Phase Input: UL/cUL Listed for use with Single
Phase Input supply.
Ease of Programming: Taken to higher levels with the new DU07
programming dial and FR-Configurator programming software.
from Mitsubishi Electric
Parameter Change
PU/EXT
Operation
Mode
an absolute must for
your drive systems.
• The popular setting dial makes operation easy
• The dial’s “clicking” sensation and notch helps make
settings with confidence
• Make settings quickly or slowly depending on how fast
the dial is turned
• Detachable keypad can be panel mounted. (Cable and
adaptor required)
• Hand/Auto indication available with optional FR-PU07-01 keypad
• Dial/key operation lock function is available
F700 LINEUP
The F700 inverter is built to
optimize 3-phase motor control,
saving energy for virtually all
general purpose applications.
Evolution of the inverter for fan and
pump applications, providing energy savings
for buildings and factories as a whole.
Windmill Start: F700 measures residual motor
slot ripple to determine both the speed and
direction of rotation of a coasting motor and can
swiftly and smoothly bring it under control when
required – whichever way it’s spinning.
Energy Saving Signal: F700 will calculate and display
your energy savings, either as dollars or kW/h.
Energy Saving Monitor List
Power Savings
Monitor Display
Power saving monitor (kW)
Power saving rate (%)
Power saving amount (kWh)
Power saving amount charge ($)
Power saving average value (kW)
Power saving rate average value (%)
Power saving charge average value ($)
Annual power saving amount (kWh)
Annual power saving amount charge ($)
Enhanced Energy Savings: An improved
version of Mitsubishi Electric’s famous energyoptimization software boosts motor efficiency
to unprecedented levels and intelligently
maximizes energy savings.
Ratio of Motor Power Consumption during Acc./Dec
Commercial
power
operation
100
80
60
V/F control
40
20
0
10
20
30
Optimum
excitation
control
40
Frequency (Hz)
50
60
Power Consumption Ratio (%)
Power Consumption (%)
Ex. of Blower Operation Characteristics
Conventional model (FR-F500)
100
12%
6%
• Energy savings results can be confirmed using the
operation panel, output terminal (CA, AM terminal)
and via networks with the newly developed energy
saving monitor.
90
F700
0
10
20
30
40
50
Power Dip Ride -Through: Allows the inverter to
continue to run during short power supply interruptions –
reducing nuisance tripping.
Motor Load Torque (%)
When power is restored during deceleration
• F700 achieves a higher level of energy
savings both during acc./dec. and constant
speed operation.
IPF
Input
Power Supply
Output
Frequency
Deceleration
Reacceleration
• Operation continues without the motor coasting when
an instantaneous power failure occurs in fan and
blower applications.
F700 VFD
Pre-Charge Function: Before PID control takes over, this
function can be used to ensure consistent fill.
Overvoltage Avoidance: The F700
measures DC bus levels when
decelerating and controls drive speed
to eliminate nuisance tripping.
Programmable Timer: Generates a signal dependent on
drive operating time — useful to plan scheduled machine
maintenance.
Independent RS-485 Connections: Allow serial communications and keypad operation at the same time with no options
needed. F700 supports Modbus RTU as well as the standard
Mitsubishi Electric protocol.
Complies with Global Standards: UL, cUL, GOST, JEM,
and CE marked for use in Europe. A radio filter is included
in the drive as standard to meet European EMC levels
(2nd Enviromental).
Improved Field Bus Capability: In addition to popular BMS protocols inlcuding Lon Works, Metasys N2 and Siemens FLN, F700
now supports Ethernet I/P, Profibus DP, and DeviceNet. BACnet
MS/TP is built-in.
Power
supply
unit
Inverter
Inverter
Up to 42 units can
be connected
CPU Master
(
when connections
are inverter only
)
FR-A7NC
Terminating
resistor
CC-Link
dedicated cable
FR-A7NC
Terminating
resistor
CC-Link network
Network management
computer
Inverter
Inverter
Pump
Air-conditioner
Advanced PID Mode: Now includes
‘sleep mode’ as well as pump scheduling
feature to allow the intelligent control of
up to 4 motors at once.
FR-A7NL
LONWORKS
FR-A7NL
Network
Remote I/O Capability: Drive I/O can
be configured over a network to work
independently of the drive, reducing cost
and making more efficient use of the
available network nodes.
Free
Topology
Node
Lighting
Node
Security system
Standard Specifications
F700 Ratings 240V Class
Input: 1 Phase / 3 Phase • Output Voltage: 3 Phase 200-240V at 60Hz
Voltage Tolerance: 170-264V at 60Hz • Available Braking Torque: 15% Torque Continuous
SLD (40°C)
LD
110% OL / 1min
120% OL / 1min
120% OL / 3 sec
150% OL / 3 sec
Hp (*1)
1
2
3
5
7.5
10
15
20
25
30
40
50/60
60
75
40
50/60
60
75
100/125
150
200
FLA
4.6
7.7
10.5
16.7
25
34
49
63
77
93
125
154
187
233
125
154
187
233
316
380
475
Hp (*1)
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
40
50
60
75
100
125
150
FLA
4.2
7
9.6
15.2
23
31
45
58
70
85
114
140
170
212
114
140
170
212
288
346
432
Model Number (*3)
Frame Size
FR-F720-00046-NA
FR-F720-00077-NA
FR-F720-00105-NA
FR-F720-00167-NA
FR-F720-00250-NA
FR-F720-00340-NA
FR-F720-00490-NA
FR-F720-00630-NA
FR-F720-00770-NA
FR-F720-00930-NA
FR-F720-01250-NA
FR-F720-01540-NA
FR-F720-01870-NA
FR-F720-02330-NA
FR-F720-01250-NAN1
FR-F720-01540-NAN1
FR-F720-01870-NAN1
FR-F720-02330-NAN1
FR-F720-03160-NA
FR-F720-03800-NA
FR-F720-04750-NA
A
B
C
C
C
D
D
E
F
F
F
G
H
H
F
G
H
H
K
K
K
Cooling Method
Protective Rating
Self Cooling
UL Type 1 –
Plenum Rated
Forced Air
Cooled
IP00 (*2)
NEMA 1
IP00 (*2)
F700 Ratings 480V Class
Input: 1 Phase / 3 Phase • Output Voltage: 3 Phase 380-480V at 50/60Hz
Voltage Tolerance: 323-528V at 50/60Hz • Available Braking Torque: 15% Torque Continuous
SLD (40°C)
LD
110% OL / 1min
120% OL / 1min
120% OL / 3 sec
150% OL / 3 sec
Hp (*1)
FLA
Hp (*1)
FLA
1
2
3
5
7.5
10
15
20
25
30
40
50/60
60
75
50/60
60
75
2.3
3.8
5.2
8.3
12.6
17
25
31
38
47
62
77
93
116
77
93
116
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
50
60
75
2.1
3.5
4.8
7.6
11.5
16
23
29
35
43
57
70
85
106
70
85
106
Model Number (*3)
Frame Size
FR-F740-00023-NA
FR-F740-00038-NA
FR-F740-00052-NA
FR-F740-00083-NA
FR-F740-00126-NA
FR-F740-00170-NA
FR-F740-00250-NA
FR-F740-00310-NA
FR-F740-00380-NA
FR-F740-00470-NA
FR-F740-00620-NA
FR-F740-00770-NA
FR-F740-00930-NA
FR-F740-01160-NA
FR-F740-00770-NAN1
FR-F740-00930-NAN1
FR-F740-01160-NAN1
C
C
C
C
C
D
D
E
E
F
F
G
H
H
G
H
H
DIMENSIONS
Frame Size
Dimensions inches (mm)
Frame Size
Cooling Method
Protective Rating
Self Cooling
UL Type 1 –
Plenum rated
Forced Air Cooled
IP00 (*2)
NEMA 1
Dimensions inches (mm)
Height
Width
Depth
H
21.7 (550)
17.1 (435)
9.8 (250)
4.9 (125)
J
27.6 (700)
18.3 (465)
9.8 (250)
5.5 (140)
K
29.1 (740)
18.3 (465)
14.2 (360)
15 (380)
Height
Width
Depth
A
10.2 (260)
4.3 (110)
4.3 (110)
B
10.2 (260)
4.3 (110)
C
10.2 (260)
5.9 (150)
D
10.2 (260)
8.7 (220)
6.7 (170)
L
39.8 (1010)
19.6 (498)
E
11.8 (300)
8.7 (220)
7.5 (190)
M
39.8 (1010)
26.8 (680)
15 (380)
F
15.8 (400)
9.8 (250)
7.5 (190)
N
52.4 (1330)
31.1 (790)
17.3 (440)
G
21.7 (550)
12.8 (325)
7.7 (195)
P
62.2 (1580)
39.2 (995)
17.3 (440)
F700 VFD
Factory Supplied DC Link Chokes
F700 Ratings 480V Class (continued)
Input: 1 Phase / 3 Phase • Output Voltage: 3 Phase 380-480V at 50/60Hz • Voltage Tolerance: 323-550V at
50/60Hz
Available Braking Torque: 15% Torque Continuous • DC Link Choke is included with the VFD
SLD (40°C)
LD
110% OL / 1min
120% OL / 1min
120% OL / 3 sec
150% OL / 3 sec
Hp (*1)
FLA
Hp (*1)
FLA
100/150
180
100
144
Model Number
(*3)
Frame
Size
FR-F740-01800-NA
Cooling
Method
Protective
Rating
H
150
216
150
180
FR-F740-02160-NA
J
200
260
150
216
FR-F740-02600-NA
J
250
325
200
260
FR-F740-03250-NA
K
300
361
250
325
FR-F740-03610-NA
K
350
432
300
361
FR-F740-04320-NA
L
400
481
350
432
FR-F740-04810-NA
L
450
547
400
481
FR-F740-05470-NA
M
500
610
450
547
FR-F740-06100-NA
M
550
683
500
610
FR-F740-06830-NA
M
650
770
550
683
FR-F740-07700-NA
N
700
866
650
770
FR-F740-08660-NA
800
962
700
866
FR-F740-09620-NA
P
900
1094
800
962
FR-F740-10940-NA
P
1000
1212
900
1094
FR-F740-12120-NA
P
IP00 (*2)
Forced Air
Cooled
Std with VFD
FR-F700 Series
Dimensions inches (mm)
Height
Width
Depth
Approx. Wt.
lb (kg)
FR-F740-01800-NA 13.4 (340) 5.9 (150) 7.5 (190)
20 (44)
FR-F740-02160-NA 13.4 (340) 5.9 (150) 7.7 (195)
22 (48)
FR-F740-02600-NA 15.9 (405) 6.9 (175) 7.9 (200)
26 (57)
FR-F740-03250-NA 15.9 (405) 6.9 (175)
28 (62)
8 (205)
FR-F740-03610-NA 15.9 (405) 6.9 (175) 9.4 (240)
29 (64)
FR-F740-04320-NA 15.9 (405) 6.9 (175) 9.4 (240)
30 (66)
FR-F740-04810-NA 17.3 (440) 7.5 (190) 9.8 (250)
35 (77)
FR-F740-05470-NA 17.3 (440) 7.5 (190)
38 (84)
10 (255)
FR-F740-06100-NA 19.5 (495) 8.3 (210) 9.8 (250)
42 (92)
FR-F740-06830-NA 19.5 (495) 8.3 (210) 9.8 (250)
46 (101)
FR-F740-07700-NA 19.7 (500) 8.7 (220) 9.8 (250)
50 (110)
FR-F740-08660-NA 19.7 (500) 8.7 (220) 10.6 (270)
57 (125)
FR-F740-09620-NA 17.8 (455) 8.5 (215) 13.6 (345) 67 (1147)
N
IP00
FR-F740-10940-NA 18.1 (460) 8.5 (215) 14.2 (360)
85 (187)
FR-F740-12120-NA 18.1 (460) 8.5 (215) 14.2 (360)
95 (209)
Notes: 1. Motor ratings shown are intended as guidelines only – based on 4 pole standard induction motors. 2. NEMA 1 conduit adapter option
required. 3. For single phase input, derate output current by 40% (Models up to F720-03800-NA, F740-04810-NA.)
Building Management Options
Gateway Communication
Network Type / Model
BACnet/IP
FR-A7N-ETH FR-A7N-XLT
(*1,*2)
(*1,*2)
X
X
-
X
-
Modbus TCP
X
-
X
-
PROFINET IO
X
-
X
-
BACnet MS/TP (*5)
-
X
X
X
Metasys N2
-
X
X
X
Siemens FLN
-
X
-
-
Conduit Attachments
Function
(two are permissible)
Model No.
Relay Output
12 Bit Digital Input
Digital Output
Ext. Analog Output
BiPolar Analog Input
High Res Analog Input
Motor Thermistor
CC-Link
DeviceNet
LonWorks
Profibus DP
Notes:
For additional information, visit www.iccdesigns.com
1. Physically mounts within VFD and powered by VFD
2. FR-E7TR option recommended. (PU connector not
available for use)
3. Communication to multiple VFD’s is possible
4. Mounted and powered external to VFD
5. BACnet MS/TP is built in to F700. Gateway required
for pre August 2010 production.
XLTR-1000
(*3,*4)
-
EtherNet/IP
Option Cards
Communication
ETH-1000
(*3,*4)
X
FR-A7AR
FR-A7AX
FR-A7AY
FR-A7AZ
FR-A7NC
FR-A7ND
FR-A7NL
FR-A7NP
Model Number
Drive Model
F720 (*1)
F740 (*1)
Length
(in) (*4)
Weight
(lbs)
5
FR-A7FN05 (*3)
01250
-
5.9"
FR-A7FN06 (*3)
01540
00770
6.2"
5
FR-A7FN07 (*3)
01870, 02330
00930, 01160
9"
15
FR-A7FN-10 (*2)
-
01800
24"
37
FR-A7FN-11 (*2)
03160, 03800,
04750
02160, 02600
24"
41
03250, 03610
24"
45
-
04320, 04810
26"
50
-
05470, 06100,
06830
26"
64
FR-A7FN-12 (*2)
FR-A7FN-13 (*2)
FR-A7FN-14 (*2)
Notes:
1. For FR-F700s smaller than listed above, they are UL Type 1, and conduit attachment is standard.
2. Mounting hardware included for standard DC chokes which ship with
VFD. Kits are powder coated similar to VFD, charcoal gray.
3. Kits are coated zinc clear.
4. Width and depth of kit match the asscociated VFD.
OPTIONS & ACCESSORIES
FR-PU07-01: 24-button keypad, alphanumeric LCD display,
upload/download parameter sets, store up to 3 sets of drive data,
battery option allows data transfer without powering up drive
FR-ADP Adaptor: Connects DU07 keypad to FR-CB20 cables
VFD Setup Software (serial port)
VFD Setup Software: Programming and diagnostic software
SC-FRPC Adaptor Cable: Connects PC to inverter for
VFD Setup Software (serial port)
UFS and FR-BU: Dynamic brake units
FR-CB201, 03, 05: RJ45 connector cables
Control Specifications
Control System
High carrier frequency PWM control (V/F control)/optimum excitation control/simple magnetic flux vector control
Output Frequency Range
0.5 to 400Hz
Frequency
Setting
Resolution
Analog Input
0.015Hz/0 to 60Hz (terminal 2, 4: 0 to 10V/12bit); 0.03Hz/0 to 60Hz (terminal 2, 4: 0 to 5V/11bit, 0 to 20mA/approx. 11bit,
terminal 1: -10V to +10V/11bit); 0.06Hz/0 to 60Hz (terminal 1: 0 to ±5V/10bit)
Digital Input
0.01Hz
Analog Input
Within ±0.2% of the max. output frequency (25°C ± 10°C)
Digital Input
Within 0.01% of the set output frequency
Frequency
Accuracy
Voltage/Frequency Characteristics
Base frequency can be set from 0 to 400Hz. Constant torque/variable torque pattern or adjustable 5 points V/F can be selected.
Starting Torque
120% (3Hz) when set to simple magnetic flux vector control and slip compensation
Acceleration/Deceleration
Time Setting
0 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected
DC Injection Brake
Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Stall Prevention Operation Level
Operation Specifications
Frequency Setting
Signal
Terminal 2, 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected. Terminal 1: -10 to +10V, -5 to 5V can be selected.
Digital Input
Four-digit BCD or 16-bit binary using the setting dial of the operation panel (when used with the option FR-A7AX)
Start Signal
Available individually for forward and reverse rotation. Start signal automatic self-holding input (3-wire input) can be selected.
Input Signals
Select any twelve signals using Pr.178 to Pr.189 (input terminal function selection) from among multi-speed selection, second function
selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after instantaneous power failure, external
thermal relay input, HC connection (inverter operation enable signal), HC connection (instantaneous power failure detection), PU operation/
external interlock signal , PID control enable terminal, PU operation, external operation switchover, output stop, start self-holding selection,
forward rotation command, reverse rotation command, inverter reset, PTC thermistor input, PID forward reverse operation switchover,
PU-NET operation switchover, NET-external operation switchover, command source switchover.
Operational Functions
Maximum and minimum frequency settings, frequency jump operation, external thermal relay input selection, polarity reversible operation,
automatic restart after instantaneous power failure operation, continuous operation at an instantaneous power failure, commercial power
supply-inverter switchover operation, forward/reverse rotation prevention, operation mode selection, PID control, computer link operation
(RS-485).
Output
Signals
Operating Status
Select any seven signals using Pr.190 to Pr.196 (output terminal function selection) from among inverter running, up-to-speed, instantaneous
power failure/undervoltage, overload warning, output frequency detection, second output frequency detection, electronic thermal relay
function pre-alarm, PU operation mode, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper
limit, PID forward rotation reverse rotation output, commercial power supply-inverter switchover MC1, commercial power supply-inverter
switchover MC2, commercial power supply-inverter switchover MC3, fan fault output, heatsink overheat pre-alarm, inverter running start
command on, deceleration at an instantaneous power failure, PID control activated, during retry, during PID output suspension, life alarm,
input MC stop signal, power savings average value update timing, current average monitor, alarm output 2, maintenance timer alarm,
remote output, minor failure output, alarm output. Open collector output (5 points), relay output (2 points) and alarm code of the inverter
can be output (4 bit) from the open collector.
When Used with the
FR-A7AY (Option)
Select any seven signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit capacitor life,
main circuit capacitor life, cooling fan life, inrush current limit circuit life.
Display
Pulse/Analog Output
Select from output frequency, motor current (steady or peak value), output voltage, frequency setting value, running speed, converter output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, reference voltage
output, motor load factor, energy saving effect, PID set value, PID process value using Pr. 54 “FM terminal function selection (pulse train
output)” and Pr. 158 “AM terminal function selection (analog output)”.
Operating Status
Output frequency, motor current (steady or peak value), output voltage, alarm indication, frequency setting, running speed, converter output
voltage (steady or peak value), electronic thermal load factor, input voltage, output voltage, road meter, cumulative energization time, actual
operation time, motor load factor, cumulative energization power, power saving effect, cumulative saving power, PID set point, PID process
value, PID deviation value, inverter I/O terminal monitor, input terminal option monitor (*1), output terminal option monitor (*1), option
fitting status monitor (*2), terminal assignment status (*2)
Alarm Definition
Alarm definition is displayed when the protective function is activated, the output voltage/current/frequency/cumulative energization time
right before the protection function was activated and the past 8 alarm definitions are stored.
Interactive Guidance
Operation guide/trouble shooting with a help function (*2)
PU
(FR-DU07/
FR-PU04)
Protective/Warning Function
Environment
Operation current level can be set (0 to 150% adjustable), whether to use the function or not can be selected
Analog Input
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, heatsink overheat, instantaneous
power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent, output phase
failure, external thermal relay operation, PTC thermistor operation, option alarm, parameter error, PU disconnection, retry count excess,
CPU alarm, power supply short for operation panel, 24VDC power output short, output current detection value over, inrush resistance
overheat, communication alarm (inverter), analog input alarm, internal circuit alarm (15V power supply), fan fault, overcurrent stall
prevention, overvoltage stall prevention, electronic thermal prealarm, PU stop, maintenance timer alarm (*1), parameter write error, copy
operation error, operation panel lock.
Ambient Temperature
-10°C to +50°C (non-freezing)
Ambient Humidity
90% RH or less (non-condensing)
Storage Temperature (*3)
-20°C to +65°C
Atmosphere
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Altitude, Vibration
Notes:
Maximum 1000m above sea level, 5.9m/s2 or less (conforms to JIS C 0040)
1. Can be displayed only on the operation panel (FR-DU07). 2. Can be displayed only on the parameter unit (FR-PU04).
3. Temperature applicable for a short period in transit, etc.
Mitsubishi Electric Automation, Inc.
500 Corporate Woods Parkway
Vernon Hills, IL 60061
Phn: (847) 478-2100
Fax: (847) 478-2253
• Programmable Automation Controllers
• Programmable Logic Controllers
• Human Machine Interfaces
• Motion Controllers
www.MEAU.com | Serving the Americas
Printed with soy inks.
L-VH-04030 • Effective March, 2011.
Specifications subject to change without notice.
©2011, Mitsubishi Electric Automation, Inc.
• Servo Systems
• Variable Frequency Drives
• Robots
• Computerized Numerical Controllers
• Low Voltage Switchgear
www.meau.com
847-478-2100
Download PDF