DTS DELTA R FULL COLOR User`s manual


Add to my manuals
44 Pages

advertisement

DTS DELTA R FULL COLOR User`s manual | Manualzz

DELTA 12

User’s Manual rel 1.0

GB

D.T.S. Illuminazione srl - ITALY http://www.dts-lighting.it

IP65

Made in Italy

2

DELTA 12

Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso scritto della D.T.S .

DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei prodotti o dei circuiti descritti.

The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S.

D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits described herein.

Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement, sans le consentement préalable de D.T.S

.

D.T.S.

se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou de design, sans préavis, à chacun de ses produits. D.T.S.

décline toute responsabilité sur l'utilisation ou sur l'application des produits ou des circuits décrits.

Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.

Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado o reproducido, total o parcialmente, sin previa autorizaciónescrita de D.T.S.

D.T.S.

se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter estético, funcional o de diseño a cada producto suyo. D.T.S.

no se asume responsabilidad de ningún tipo sobre la utilización o sobre la aplicació n de los productos o de los circuitos descritos.

3

DELTA 12

INDEX:

1- SYMBOLS

2- GENERAL WARNING

3- GENERAL WARRANTY CONDITION

4- TECHNICAL FEATURES

5- ACCESSORIES

4

4

4

5

5

6- IMPORTANT SAFETY INFORMATION

6.1 Fire prevention

6.2 Prevention of electric shock

6.3 Protection against direct light radiation

6.4 Safety

6.5 Level of protection against the penetration of solid and liquid matter

7

8

8

7- VOLTAGE AND FREQUENCY

8- INSTALLATION

8.1 Safety cable

8.2 Protection against liquid

8.3 Movement

8.4 Risk of fire

8.5 Forced ventilation

8.6 Ambient temperature

9- MAINS CONNECTION

9.1 Protection:

10- DMX SIGNAL CONNECTION

10.1 DMX Addresses

10.2 Selecting the DMX address

9

10

11- FIRMWARE UPDATING 11

12- DISPLAY FUNCTIONS 12

13- AUTOMATIC OPERATION 17

13.1 CUPr-RAIn-CU01/CU16-Wh01/Wh16

13.2 ChPr MASTER/SLAVE

13.3 Rec mode

14- PERIODIC CLEANING 19

15- PERIODIC CONTROLS 19

16- REPLACING THE LENSES 20

17- DMX PROTOCOL 21

4

1- SYMBOLS

Graphic symbols used on this manual:

THIS SYMBOL INDICATES A HOT SURFACE

DELTA 12

THIS SYMBOL INDICATES ELECTRIC SHOCK RISK

!

F

THIS SYMBOL INDICATES GENERAL RISK

THIS SYMBOL MEANS “DO NOT PLACE THE UNIT ON

INFLAMMABLE SURFACES”

1M

THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO

BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT

2- GENERAL WARNING

Read the instruction contained in this user manual carefully, as they give important information regarding safety during installation, use and maintenance.

The device is not for domestic use and must be installed by a qualified electrician or experienced person.

The device must always be equipped with an efficient ground connection.

3- GENERAL WARRANTY CONDITIONS

The unit is guaranteed for 36 months from the date of purchase against manufacturing material defects.

5

DELTA 12

4- TECHNICAL FEATURES

DELTA 12 FC is the brightest LED colour changer in its category (22.050 Lux at 5 m).

DELTA 12 FC light source is composed of 48 LEDs Full Colour (RGBW) with a total luminous flux of 26.000 lumens. The multi-chip RGBW Full Colour generation ensures an enhanced luminous quality, offering perfect uniformity of light beams, plus high mixing quality for RGBW colours.

The unit is available with Ultra-Narrow, Narrow, Medium and Wide lenses, plus different holographics filters offering a variety of projection angles.

The DELTA 12 FC can generate 16 million colours; colour temperature can be varied from 2700°K to 6500°K.

The unit is also available as DELTA 12 CT, featuring 48 x Dynamic White LEDs.

The unit is fully rated IP65. The unit has an electronic full-range AC 90-260 V / 50-60 Hz power supply

(reliable operation even in the case of voltage drops).

The unit can operate in vertical, horizontal or inverted positions, and can be positioned on the floor or ground, or fitted to trusses.

D.T.S. Product codes:

03.LDF006.F08

DELTA 12 FC (FULL RGBW LEDs) *Ultra-Narrow lenses

03.LDF006.F12

DELTA 12 FC (FULL RGBW LEDs) *Narrow lenses

03.LDF006.F12WS

DELTA 12 FC (FULL RGBW LEDs) *Narrow lenses *Wireless DMX ready

03.LDF006.F25

DELTA 12 FC (FULL RGBW LEDs) *Medium flood lenses

03.LDF006.F25WS

DELTA 12 FC (FULL RGBW LEDs) *Medium flood lenses *Wireless DMX ready

03.LDF006.F45

DELTA 12 FC (FULL RGBW LEDs) *Wide flood lenses

03.LDF006.F45WS

DELTA 12 FC (FULL RGBW LEDs) *Wide Flood lenses *Wireless DMX ready

03.LDF006.FW08

DELTA 12 CT (FULL WHITE LEDs) *Ultra-Narrow lenses

03.LDF006.FW12

DELTA 12 CT (FULL WHITE LEDs) *Narrow lenses

03.LDF006.FW25

DELTA 12 CT (FULL WHITE LEDs) *Medium flood lenses

03.LDF006.FW45

DELTA 12 CT (FULL WHITE LEDs) *Wide flood lenses

LED technology

DELTA 12 FC: 48 x FULL RGBW LEDs; 22.050 Lux at 5 m (Ultra-Narrow lenses); 17.728 Lumens; CRI > 90

DELTA 12 CT: 48 x FULL WHITE LEDs; 31.972 Lux at 5 m (Ultra-Narrow lenses); 25.700 Lumens; CRI > 90

Colour temperature range: 2700°K - 6500°K

LEDs average lifespan: 100.000 hours

No infrared / no ultraviolet emissions

Optical group

Four interchangeable lenses sets available:

Ultra-Narrow; Narrow; Medium flood and Wide flood

8 additional (optional) holographic filters available (user interchangeable): 10° / 20° / 30° / 40° / 60° / 80° /

60° x 10° / 75° x 45°

User interface

7 segments display + 4 soft keys; Infrared remote control

Independent operation

Fully programmable via built-in user interface

Master or Slave capability (chains of up to 32 interconnected units)

Control

Remotely controlled by cable or wireless (wireless on request); RDM;

USITT DMX 512 serial digital protocol (reception / transmission)

10 DMX channels

Protection

Full IP65 protection level

6

4- TECHNICAL FEATURES

Power supply / consumption

Full-range AC 90-260 V / 50-60 Hz

Power consumption: 500W

Thermal

Operating ambient temperature: -10° / +40°

Weight

18 Kg

Certifications and safety

CE certification; LED class: Class 2 LED product

Dimensions

Packaging Dimensions (LxWxH)

630 x 500 x 660 mm

Weight: 20 Kg

Unit Dimensions (LxWxH)

454x205x443mm

Weight: 18 Kg

DELTA 12

5- ACCESSORIES

Optional (on request)

• Lenses set Ultra-Narrow (D.T.S. Code: 03.LK.130)

• Lenses set Narrow (D.T.S. Code: 03.LK.127)

• Lenses set Medium flood (D.T.S. Code: 03.LK.128)

• Lenses set Wide flood (D.T.S. Code: 03.LK.129)

• Diffusion Frost Glass (Code: 0506V022.F)

• Wireless DMX receiver card (Code: 03.LA.012)

• External 2dBi IP65 Omni-directional Antenna (Code: 0508A040)

• “C” Clamp G60 black (max. load 50Kg) (Code: 0521A004)

• “C” Clamp G60 chrome (max. load. 50Kg) (Code: 0521A004.20)

• Safety wire (3mm x 60 cm), ring spring catch, max. capacity load 60Kg (Code: 0521A010)

7

DELTA 12

6- IMPORTANT SAFETY INFORMATION

6.1 Fire prevention:

-Never locate the fixture on any flammable surface.

F

-Minimum distance from flammable materials: 1 m.

-Minimum distance from the closest illuminable surface: 1 m.

1M

-Replace any blown or damaged fuses only with those of identical value (6,3A T).

Refer to the wiring diagrams if there is any doubt.

-Connect the projector to mains power via a thermal magnetic circuit breaker.

6.2 Prevention of electric shock:

-High voltage is present inside the unit. Isolate the projector from the mains supply prior to performing any function which involves touching the inside of the unit.

-The level of technology inherent in the DELTA 12 requires the assistance of specialised personnel for all servicing. Please refer to an authorised D.T.S. service centre.

-A good earth connection is essential for proper functioning of the projector.

Never connect the unit without proper earth connection.

-The fixture should be located in places with a good air ventilation.

6.3 Protection against direct light radiation:

-Never turn the unit on if any of the lenses or the glass lenses protection is damaged.

-Never look directly the LEDs when they are on.

6.4 Safety: !

-The projector should always be installed with bolts, clamps and other tools that are capable of supporting the weight of the unit.

-Always use a second safety chain to sustain the weight of the unit in case of the failure of the main fixing point.

-The external surface of the unit, at various points, may exceed 80°C.

Never handle the unit until it’s on.

-Never install the fixture in an enclosed area lacking sufficient air flow.

-The ambient temperature should not exceed 40°C.

6.5 Level of protection against the penetration of solid and liquid matter:

!

-The projector is classified as an outdoor appliance and its protection level against the penetration of solid and liquid matter is IP 65.

8

DELTA 12

.7- VOLTAGE AND FREQUENCY:

DELTA 12 can operate at 90-260 V AC / 50 or 60 Hz.

8- INSTALLATION:

DELTA 12 may be either floor or ceiling mounted.

For floor mounting installations, the unit is supplied with four rubber mounting feet on the base.

For ceiling mounted installations, we reccommend the use of appropriate clamps to fix the unit to the mounting surface.

The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to move or shake whilst the DELTA 12 is moving.

The DELTA 12 is fitted with 7 fixing points on the bottom used to attach accessories (clamps, hooks,

.

etc.)

8.1 Safety cable:

!

We recommend the use of a safety cable or chain connected to the DELTA 12 and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail.

Make sure that the iron cable or chain can bear the weight of the entire unit.

You may attach the safety chain to the holes located on the base of the fixture.

8.2- Protection against liquids

If IP 65 protection is impaired for any reason, do not expose this product to external atmospheric agents, because it could be damaged.

8.3- Movement

The projector has a maximum movement of 90° for Tilt.

Do not place any obstructions in the path of the projector's movement.

90°

90°

!

WARNING

Do not place any object in the path of the projector’s movement

9

DELTA 12

8.4- Risk of fire

Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT.

F

Minimum distance from the object being illuminated is 1 MT.

1M

8.5- Forced ventilation

You will note, on inspection, that the unit features various air inlets and cooling fans located on the head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation.

Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.

8.6- Ambient temperature

The projector should never be installed in places that lack a constant air flow.

The ambient temperature should not exceed 40°C.

9- MAINS CONNECTION:

DELTA 12 can operate at 90-260 V AC / 50 or 60 Hz.

Prior to connecting the unit to your mains supply, ensure that the model in your possession correctly matches the mains supply available.

For connection purposes, ensure that your plug can support 6 amps at 110V and 3 amps at 230V each unit connected.

Strict adherence to regulatory norms is strongly recommended.

03.LDF006.F08

03.LDF006.F12

03.LDF006.F25

03.LDF006.F45

03.LDF006.FW08

03.LDF006.FW12

03.LDF006.FW25

03.LDF006.FW45

FUSE: 6,3A T

DMX IN / OUT

MAINS

Electronic power supply

90-260 V AC / 50-60 Hz

03.LDF006.F12WS (WIRELESS DMX READY)

03.LDF006.F25WS (WIRELESS DMX READY)

03.LDF006.F45WS (WIRELESS DMX READY)

DMX IN / OUT

Panel connector for external WIRELESS DMX Antenna

FUSE: 6,3A T

MAINS

Electronic power supply

90-260 V AC / 50-60 Hz

Metal support for external WIRELESS DMX Antenna

9.1 Protection:

The use of a thermal magnetic circuit breaker is recommended for each DELTA 12.

A good earth connection is essential for the correct operation of the projector.

!

10

DELTA 12

10- DMX SIGNAL CONNECTION

The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a XLR

5 or 3 pins connector. Ensure that the conductors do not touch each other.

Do not connect the cable ground to the XLR chassy.

The plug housing must be isolated.

Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the second one.

This way, all the projectors are cascade connected.

NB. If the display showing the DMX address flashes, then one of the following errors has occurred:

- DMX signal not present

- DMX address not valid

- DMX reception problem

CONTROLLER

S T A N D A R D

D M X 5 1 2

5

4

1

2

1=GND

2=DATA-

3=DATA+

3

DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT

For Installations where long distance DMX cable connections are needed, we suggest to use a DMX terminator.

The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor between pin 2 and 3.

The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.

5

4

3

2

1

OUT

PLACE A 120 OHM RESISTOR BETWEEN PIN 2

AND 3 OF A MALE XRL CONNECTOR AND PLUG IT

INTO THE DMX OUT PANEL CONNECTOR OF THE

LAST UNIT CONNECTED TO THE DMX LINE

120 ohm

PIN 3

PIN 2

Please note that the XLR connectors installed on the DELTA 12 have an IP20 protection rate.

Thus, for any application where an IP65 rate is needed, the XLR connectors must be protected within an IP65-rated container.

!

11

DELTA 12

10.1 DMX Addresses:

DELTA 12 can be used in 3 different DMX modes: 10 DMX control channels, 6 DMX control channels or

15 DMX control channels.

Here below is described the DMX channels addressing for the controller when DELTA 12 is set to

10 DMX control channels :

Projector 1 A001

Projector 2 A011

Projector 3 A021

…..

A….

projector 6 A051

If you want to select the next projector, just add “10”

10.2 Selecting the DMX address:

1) Press the UP-DOWN key until you reach the required DMX address.

The numbers on the display will start to flash (but the new DMX address hasn't yet been set).

2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now controlled by the new DMX address.

TIPS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.

11- FIRMWARE UPDATING

!

Warning:

This procedure require a base knolewge of computer applications and Windows

Hyperterminal program. Please refer to an authorised D.T.S. service centre.

To update the software version of the DELTA 12 you need:

D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008).

USB-DMX Driver for the D.T.S. RED BOX interface.

D.T.S. Firmware upgrade utility program.

(The driver and the installation procedure are available in our web site www.dts-lighting.it)

Updating the software version.

Please follow the procedure below to perform the update:

1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the unit software.

2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.

3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.

4. Download the new software version into the unit by using D.T.S. Firmware upgrade utility program.

It will be possible to download the software from the reserved area of D.T.S. web site:

Www.dts-lighting.it.

12- DISPLAY FUNCTIONS

12

DELTA 12

MENU ENTER

DOWN UP

DISPLAY FUNCTIONS

The DELTA 12 display panel shows all the available functions. Using these functions, it is possible to change some of the parameters and add some functions. Changing the D.T.S. setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it.

Carefully follow the instructions below before carrying out any variations or selections.

NOTE: the symbol shows which key has to be pushed to obtain the desired function.

Software version 2.20

MENU Up-Down ENTER

REVERSE DISPLAY

Reverses display's reading depending on the mounting position (on the ground or suspended).

Up-Down

Up-Down

DISPLAY STAND BY

To turn off the display (after 5 seconds)

Or leave it always on.

ENTER Up-Down

ENTER Up-Down

Floor position

Suspension

position

ENTER

ENTER

Display OFF

ENTER

Display always ON

ENTER

MENU Up-Down

DMX MODE

To select DMX mode: 10 ch (Default), 6 ch, 15 ch and MACRO mode

MACRO

MACRO Function, enable channel mapping macro rainbow effects

STD (default)

ENTER Up-Down

Up-Down

Up-Down

Up-Down

10 CHANNELS

6 CHANNELS

15 CHANNELS

ENTER Up-Down

ENTER

Default

ENTER

ENTER

ENTER

ENTER

No rainbow macros

(Default)

Rainbow macros activated

13

ENTER Up-Down MENU Up-Down ENTER

LED

RGBA Min/Max, Smooth, Compression,

Sync level values settings and Boost mode

Up-Down

RGBA MINIMUM VALUES

This menu allow to select the minimum levels for Red, Green,

Blue and Amber

RGBA MAXIMUM VALUES

This menu allow to select the maximum levels for Red, Green,

Blue and Amber

These settings have priority on

Master Dimmer (DMX channel 2)

Up-Down

Up-Down

SMOOTH VALUE

This menu allow to select the value of the delay (in milliseconds) for

RGBA and Dimmer channels reaction to DMX or Program variation.

Off = 25 ms delay (Fast response)

20 = 250 ms delay (Slow response)

COMPRESSION

This menu allow to select between

Linear current output or Quadratic current output for LEDs

Default = Linear

SYNC

This menu allow to adjust the PWM frequency value (Hz) in order to reduce flickering in the process of your camera recordings

BOOST DRIVING

This menu allow to increase the

LED’s current from 350 mA to 500 mA

Up-Down

Up-Down

Up-Down

Up-Down

Up-Down

MENU Up-Down

AUTOMATIC MODE

Automatic demo game without

DMX controller

ChPr

Chase with 16 steps previously created in REC MODE

Speed and Wait time selectable by user

ENTER

CUPr

RGB values selectable by user

Rainbow (rAIn)

Rainbow colours effect.

Speed time selectable by user

CU01-CU16

Color Macros as on DMX channel

8 (Macro)

ENTER Up-Down

ENTER Up-Down

ENTER Up-Down

ENTER Up-Down

ENTER Up-Down

ENTER Up-Down

ENTER Up-Down

ENTER Up-Down

Up-Down

ENTER

ENTER Up-Down

ENTER

ENTER Up-Down ENTER

Up-Down

DELTA 12

Default = 0

ENTER

Default = 100

ENTER

Default = 0

ENTER

Default = 100

ENTER

Default = 0

ENTER

Default = 100

ENTER

Default = 0

ENTER

Default = 100

ENTER

Range = Off - 20

Default = 4 ENTER

Linear = Linear current output

Quadratic =

Linear light output

ENTER

ENTER

Range = 610 Hz -10 KHz

Default = 610 Hz ENTER

With BOOST active, the LED’s current is setted to 500 mA

(30% more gain).

Default = Enabled

ENTER Up-Down

ENTER

ENTER

14

DELTA 12

MENU Up-Down

AUTOMATIC MODE

Automatic demo game without

DMX controller

WHITE MACROS

16 macros for White colour from

2000°K to 7200°K

ENTER

DIMMER

Dimmer level selectable by user as on DMX channel 2 (Dimmer)

Dimmer level is active for all the programs and macros

SHUTTER

Shutter level selectable by user as on DMX channel 1 (Shutter)

Shutter level is active only for

CU01/CU16 and Wh01/Wh16 macros

ESC

Esc from Automatic Mode Menu

ENTER Up-Down ENTER Up-Down ENTER

ENTER Up-Down

ENTER Up-Down

ENTER

ENTER

MENU Up-Down

REC MODE

In DMX Recorder Mode, it is possible to create and store the scenes of the ChPr by using an external DMX controller.

The unit must be setted to 10

DMX channels mode

ENTER ENTER

DMX Recorder Mode

For the programming of ChPr by using a DMX controller, besides the 10 channels necessary to control the unit a further 3 DMX channels are needed.

So that in RECORDER mode (via DMX) the unit will need 13 channels to be correctly programmed.

The three new DMX channels are:

DMX channel 11 = SCENES channel

From 0-10 = no function (r001)

From 11-255 are displayed the programmable scenes (max 16 scenes from M001 to M0016)

DMX channel 12 = EDIT channel:

-From 0-19 = no function

-From 20-234 the unit runs the configuration given by the received input DMX values.

With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene.

-From 235-255 the unit runs the configuration given by the received input DMX values closing the sequence as last scene.

With the channel REC it is possible to record the selected scene as last scene.

DMX channel 13 = RECORDING channel

Records the set scene with a variation between 0 to 255 (the display flashes indicating that the scene has been recorded). It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene. If ChPr is not closed, by indicating the last scene (Edit channel between 235-255), in playback mode all 16 scenes will be played through even if not programmed.

15

DELTA 12

MENU Up-Down

SLAVE MODE

Slave mode for ChPr program.

All slave units will be synchronised with master unit, running their own Chpr program.

ENTER ENTER Up-Down ENTER

MENU Up-Down

WIRELESS DMX

Wieless DMX enabled / disabled.

By activating WDMX MODE, it will be possible to control DELTA 12 via

D.T.S. ANTENNA Wireless DMX

Transmitter (cod. 03.E1271).

WIRELESS DMX system on

DELTA 12 is available on request.

ENTER Up-Down ENTER Up-Down

UNLINK = LOG OUT

ENTER

WIRELESS DMX SYSTEM

ENABLED

WIRELESS DMX SYSTEM

DISABLED

NOTE:

Wireless DMX receiver card needed (cod. 03.LA.012).

External IP65 2dbi omnidirectional Antenna needed (cod. 0508A040)

ENTER

Logging on DELTA 12 (WIRELESS DMX must be enabled on DELTA 12 unit)

ENTER ENTER Up-Down ENTER

To log on the Delta 12 in the WIRELESS system simply press and quickly release the function button on the transmitter .

The transmitter will start flashing rapidly red/green scanning for new free receivers / DELTA 12 units. When a DELTA 12 logs on to the transmitter the LINK green light on transmitter starts to flash rapidly.

After approximately 10 seconds the transmitter will jump back to normal mode and continue transmitting data. The DELTA 12 now try to synchronize to the transmitter.

When synchronized to the transmitter, 2 different modes are possible:

1. Antenna transmitter has detected and transmits a DMX signal, in this mode a solid green light is seen on the transmitter and solid display is seen on DELTA 12.

2. No DMX signal connected, the Antenna transmitter will flash red/green; display blinking on DELTA 12.

To log DELTA 12 off from a transmitter simply select UNLINK function under WIRELESS DMX MENU and press ENTER.

When DELTA 12 is logged off the display is blinking, meaning its available for log in on a new transmitter.

Logging out a DELTA 12.

Select UNLINK function under WIRELESS DMX MENU and press ENTER.

When DELTA 12 is logged off the display is blinking, meaning its available for log in on a new transmitter.

Logging out all DELTA 12 linked to a transmitter.

Press and hold the function button of the transmitter for about 3 seconds.

When the display is blinking on DELTA 12, it mean that the units are logged out.

Transmitter, LEDs Status:

Flashing red/green, no dmx connected.

Solid green, dmx signal detected and transmitted.

Fast flashing red/green, log in mode (every free DELTA 12 unit, not logged in to any other transmitter, will be logged on)

DELTA 12, Status:

Display blinking, not logged on to a transmitter (free).

Solid display, logged on to a transmitter and receiving dmx data.

16

MENU Up-Down

EMERGENCY

Emergency operating mode.

By setting Emergency mode, it will be possible to select one of the 16 pre-programmed WHITE cues that will then ran if DMX signal is missing or not available.

Usefull for Emergency EXIT ilumination on public areas.

ENTER Up-Down

MENU Up-Down

DEFAULT

To restore default settings

ENTER

MENU Up-Down

TEMPERATURE

Unit temperature

ENTER Up-Down

MENU Up-Down ENTER

FAN

Fan max speed regulation

Off (fan always off) -12-14-16-18-20-22-24 Volt

MENU Up-Down

LIFE TIME

This menu show the total unit life time and the RGBA life time

ENTER Up-Down

.

ENTER Up-Down

ENTER

ENTER

ENTER

ENTER

ENTER

DELTA 12

ENTER

ENTER

Default = OFF

Default = White 1

Default = 255

MENU Up-Down

TEST MODE

RGBA colours test with rainbow

ENTER

MENU Up-Down

SOFTWARE

Software version

ENTER

Not yet activated

.

.

17

DELTA 12

13-AUTOMATIC OPERATION (AUTO)

DELTA 12 can work in automatic mode without a DMX controller. First of all connect the projectors with a DMX cable (picture below). A maximum quantity of 32 slave units can be connected to the same

Master unit.

MASTER SLAVE 1 SLAVE 2 SLAVE 32

DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX IN

To activate Auto mode on the first unit, use the menu to run through the different modes until AUTO appears on the display, and press enter.

Now it is possible to choose between the different pre-programmed games (CUPr-RAIn-CU01/CU16-

Wh01/Wh16) or ChPr which is user programmable through REC mode. To confirm game activation press

ENTER on the selected GAME.

13.1 CUPr-RAIn-CU01/CU16-Wh01/Wh16

The first unit that will work as a Master should be placed in Automatic mode (AUTO), the other units have to be placed in 10 channels DMX mode (MODE 10CH) and the DMX address should be set at A001.

For RaIn (rainbow) game it is possible to select the speed for the colour changhing (SPEE).

DIMMER function (in AUTOMATIC MODE) is active for all the programs.

SHUTTER function (in AUTOMATIC MODE) is active only for CU01/CU16 and Wh01/Wh16 macros.

13.2 ChPr MASTER/SLAVE

The first unit that will function as a Master must be set to Automatic mode (AUTO), the other units must be set to Slave mode (SLAV), selectable through the menu. In this way all the Slave units will be synchronised with the master and running their own ChPr game.

On the master unit it is possible to vary the Speed time (SPEE) for the colour changhing and the Wait time (UAIt) between the steps.

Speed time and Wait time on the Master, have priority on the slave units.

NB: It is possible to run GA.Pr on the other units even though these do not have GA.Pr programmed.

You can do this by setting the units to 10 channels DMX mode (MODE 10CH) and selecting DMX address

A001.

18

DELTA 12

13.3 Rec mode

It is possible to program your own game on DELTA 12 that will then run it in AUTO mode (ChPr).

Each unit can have its own programmed game.

In REC mode the unit must be set to 10 DMX channels mode.

To program the ChPr by using a DMX controller, you need 3 more channels in addition to the 10 channels necessary to control the unit.

So that in RECORDER mode (via DMX) the unit will need 13 DMX channels to be correctly programmed.

The three new DMX channels are:

DMX channel 11 = SCENES channel

From 0-10 = no function (r001)

From 11-255 are displayed the programmable scenes (max 16 scenes from M001 to M0016)

DMX channel 12 = EDIT channel:

-From 0-19 = no function

-From 20-234 the unit runs the configuration given by the received input DMX values.

With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene.

-From 235-255 the unit runs the configuration given by the received input DMX values closing the sequence as last scene.

With the channel REC it is possible to record the selected scene as last scene.

DMX channel 13 = RECORDING channel

Records the set scene with a variation between 0 to 255 (the display flashes indicating that the scene has been recorded). It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene. If ChPr is not closed, by indicating the last scene (Edit channel between 235-255), in playback mode all 16 scenes will be played through even if not programmed.

19

DELTA 12

14- PERIODIC CLEANING

Front lenses Glass:

The dust can reduce the luminous output substantially. Regularly clean the front lenses glass using a soft cotton cloth, dampened with a specialist glasses cleaning solution.

15- PERIODIC CONTROLS

Mechanical parts:

Periodically check all mechanical parts and the gaskets. Please refer to an authorised D.T.S. Service centre for any operation involving of the unit if needed.

Electrical components:

Check for unit correct earthing. Please refer to an authorised D.T.S. Service centre for any operation involving of the unit if needed.

Fuse replacement:

Locate the fuse, which protect the electronics, in the base of the DELTA 12.

!

Using a multimeter, test the condition of the fuse, replacing it with one of equivalent type (6,3A T) if necessary.

Attention: Disconnect mains power prior to remove the fuse to be tested.

20

DELTA 12

16- REPLACING THE LENSES

• Lenses set Ultra-Narrow (D.T.S. Code: 03.LK.130)

• Lenses set Narrow (D.T.S. Code: 03.LK.127)

• Lenses set Medium flood (D.T.S. Code: 03.LK.128)

• Lenses set Wide flood (D.T.S. Code: 03.LK.129)

Attention: The lenses replacement must be made by D.T.S. Personnel or experienced person. Wrong manoeuvres can void the IP 65 protection.

!

To replace the lenses sets proceed as follow:

1- Remove these 6 screws on both

Sides of the rear head assembly

2- Remove the top head cover

3- Loose these 9 screws and remove the old lenses set, then apply the new lenses set and tighten the screws previously removed.

4- Put in place the top head cover and tighten the 6 screws on both sides of the rear head assembly previously removed.

21

DELTA 12

17-DMX PROTOCOL

DELTA 12 FC

10 CHANNELS MODE (Default)

1 SHUTTER

2 DIMMER

3 RED

4 GREEN

5 BLUE

6 AMBER

7 WHITE (Pre-programmed whites at different colour temperatures)

8 CTC

9 COLOURS MACRO

10 FUNCTIONS

DMX CHANNEL

1 Parameter: SHUTTER

DMX range

Value

0-9

10-19

20-29

30-119

120-149

150-179

180-204

205-229

230-255

Mid point

DMX value

Move range

(degrees)

5

14

24

192

218

240

Mode Option Function

Black-out

Open

Black-out

Open

Pulse open at variable speed from slow to fast (42,6 s - 120 ms)

Pulse close at variable speed from slow to fast (42,6 s - 120 ms)

Strobe at variable speed from slow to fast (3,27 s - 30 ms)

Random Strobe (Master and RGBW active)

Random Strobe (Full)

DMX CHANNEL 2

Parameter: DIMMER

DMX range

Value

0-255

Mid point

DMX value

DMX CHANNEL 3

Move range

(degrees)

Parameter: RED

Mode Option Function

Proportional dimmer

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option Function

Proportional colour

22

DELTA 12

DMX CHANNEL 4

Parameter: GREEN

DMX range

Value

0-255

DMX CHANNEL

Mid point

DMX value

5

Move range

(degrees)

Parameter: BLUE

Mode Option Function

Proportional colour

DMX range

Value

0-255

DMX CHANNEL

Mid point

DMX value

6

Move range

(degrees)

Parameter:

Mode

AMBER

Option Function

Proportional colour

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option Function

Proportional colour

DMX CHANNEL

0-55

56-105

106-155

7

23

80

130

Parameter:

DMX range Mid point

Value DMX value

WHITE (Pre-programmed White at diff. color temperature)

Move range

(degrees)

Mode Option Function

No Function

Full (Red-Green-Blue-White at Full)

White DTS

IF CHANNEL 10 (FUNCTIONS) = CUSTOM WHITE RECALL (Dmx range value 0 - 79)

156-205

206-255

180

225

Custom White Recall

43 color temp. Correction Macros: 2700°K - 6500°K)

IF CHANNEL 10 (FUNCTIONS) = CUSTOM WHITE CREATE (Dmx range value 80 - 160)

156-205 180 Custom White Create (RGBW levels selectable by DMX)

206-255 225 White CTC (Channel 8 CTC enabled

43 color temp. Correction Macros: 2700°K - 6500°K)

23

DMX CHANNEL 8 Parameter:

DMX range Mid point

Value DMX value

Move range

(degrees)

CTC (Colour temperature correction)

Mode Option

IF CHANNEL 7 (White) = WHITE CTC (Dmx range value 206 - 255)

0-255

Function

43 colour temp. Correction Macros: 0= 2700°K / 128= 4500°K / 255= 6500°K

IF CHANNEL 7 (White) = NO FUNCTION (Dmx range value 0 - 43)

0-255 Smooth RGBW linear Hue correction

DMX CHANNEL 9 Parameter: COLOUR MACROS

IF:

MENU Up-Down

ENTER

Up-Down

DMX range

Value

0-14

15-29

30-44

45-59

60-74

75-89

90-104

105-119

120-134

135-149

150-164

165-179

180-194

195-209

210-225

226-239

240-255

Mid point

DMX value

Move range

(degrees)

ENTER Up-Down

Mode

ENTER

PLEASE CHECK PAGE 12

Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 16

24

DELTA 12

DMX CHANNEL 9 Parameter: COLOUR MACROS

IF:

MENU Up-Down

111-118

119-126

127-134

135-142

143-150

151-158

159-166

167-174

175-182

183-190

191-198

199-206

207-214

215-222

223-230

231-238

239-246

247-255

DMX range

Value

0-14

15-22

23-30

31-38

39-46

47-54

55-62

63-70

71-78

79-86

87-94

95-102

103-110

DMX CHANNEL

ENTER

Up-Down ENTER

PLEASE CHECK PAGE 12

ENTER Up-Down

Mid point

DMX value

Move range

(degrees)

10

Mode Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 4

Macro 5

Macro 6

Macro 7

Macro 8

Macro 9

Macro 10

Macro 11

Macro 12

Macro 13

Macro 14

Macro 15

Macro 16

Rainbow Speed 1 (1 Sec.)

Rainbow Speed 2 (5 Sec.)

Rainbow Speed 3 (10 Sec.)

Rainbow Speed 4 (20 Sec.)

Rainbow Speed 5 (30 Sec.)

Rainbow Speed 6 (60 Sec.)

Rainbow Speed 7 (120 Sec.)

Rainbow Speed 8 (180 Sec.)

Random Speed 1 (0.5 sec.)

Random Speed 2 (1 Sec.)

Random Speed 3 (2 Sec.)

Random Speed 4 (5 Sec.)

Random Speed 5 (10 Sec.)

Random Speed 6 (30 Sec.)

Parameter: FUNCTIONS (Recall, Create and Store the Custom white)

DMX range Mid point

Value DMX value

0-79

80-160

161-255

Move range Mode Option Function

(degrees)

Custom White Recall (Enable CH 7 for Custom white Recall)

Custom White Create (Enable CH 7 for Custom white Creation)

Custom White Store (Store the Custom White created )

25

DELTA 12

DELTA 12 FC

6 CHANNELS MODE

1 SHUTTER

2 DIMMER

3 RED

4 GREEN

5 BLUE

6 AMBER

DMX CHANNEL

1 Parameter: SHUTTER

DMX range

Value

0-9

10-19

20-29

30-119

120-149

150-179

180-204

205-229

230-255

Mid point

DMX value

Move range

(degrees)

5

14

24

192

218

240

Mode Option Function

Black-out

Open

Black-out

Strobe at variable speed from slow to fast (3,27 s - 30 ms)

Pulse open at variable speed from slow to fast (42,6 s - 120 ms)

Pulse close at variable speed from slow to fast (42,6 s - 120 ms)

Open

Random Strobe (Master and RGBW active)

Random Strobe (Full)

DMX CHANNEL

DMX range

Value

0-255

2 Parameter: DIMMER

Mid point

DMX value

Move range

(degrees)

Mode

DMX CHANNEL 3

Parameter: RED

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode

Option

Option

Function

Proportional dimmer

Function

Proportional colour

26

DELTA 12

DMX CHANNEL 4

Parameter: GREEN

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode

DMX CHANNEL 5

Parameter: BLUE

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode

DMX CHANNEL 6

Parameter: AMBER

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode

Option

Option

Option

Function

Proportional colour

Function

Proportional colour

Function

Proportional colour

27

DELTA 12

DELTA 12 FC

15 CHANNELS MODE

1 SHUTTER

2 DIMMER

3 DIMMER FINE

4 RED

5 RED FINE

6 GREEN

7 GREEN FINE

8 BLUE

9 BLUE FINE

10 AMBER

11 AMBER FINE

12 WHITE (Pre-programmed whites at different colour temperatures)

13 CTC

14 COLOURS MACRO

15 FUNCTIONS

DMX CHANNEL

1 Parameter: SHUTTER

DMX range

Value

0-9

10-19

20-29

30-119

120-149

150-179

180-204

205-229

230-255

Mid point

DMX value

Move range

(degrees)

5

14

24

192

218

240

Mode Option Function

Black-out

Open

Black-out

Open

Pulse open at variable speed from slow to fast (42,6 s - 120 ms)

Pulse close at variable speed from slow to fast (42,6 s - 120 ms)

Strobe at variable speed from slow to fast (3,27 s - 30 ms)

Random Strobe (Master and RGBW active)

Random Strobe (Full)

DMX CHANNEL 2

Parameter: DIMMER

DMX range

Value

0-255

Mid point

DMX value

DMX CHANNEL 3

Move range

(degrees)

Parameter:

Mode

DIMMER FINE

Option Function

Proportional dimmer

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option Function

Proportional dimmer

28

DELTA 12

DMX CHANNEL 4

Parameter: RED

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 5

Parameter:

Mode

RED FINE

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 6

Parameter: GREEN

Mode

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 7

Parameter:

Mode

GREEN FINE

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 8

Parameter: BLUE

Mode

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

Mode

Option

Option

Option

Option

Option

DMX CHANNEL 9

Parameter: BLUE FINE

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

Mode Option

Function

Proportional colour

Function

Proportional colour

Function

Proportional colour

Function

Proportional colour

Function

Proportional colour

Function

Proportional colour

29

DELTA 12

DMX CHANNEL 10

Parameter: AMBER

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 11

Mode

Parameter: AMBER FINE

Option

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

Mode Option

Function

Proportional colour

Function

Proportional colour

DMX CHANNEL

DMX range Mid point

Value DMX value

0-55

56-105

106-155

12 Parameter: WHITE (Pre-programmed White at diff. color temperature)

23

80

130

Move range

(degrees)

Mode Option Function

No Function

Full (Red-Green-Blue-White at Full)

White DTS

IF CHANNEL 15 (FUNCTIONS) = CUSTOM WHITE RECALL (Dmx range value 0 - 79)

156-205

206-255

180

225

Custom White Recall

43 color temp. Correction Macros: 2700°K - 6500°K)

IF CHANNEL 15 (FUNCTIONS) = CUSTOM WHITE CREATE (Dmx range value 80 - 160)

156-205 180 Custom White Create (RGBW levels selectable by DMX)

206-255 225 White CTC (Channel 8 CTC enabled

43 color temp. Correction Macros: 2700°K - 6500°K)

30

DMX CHANNEL 13 Parameter: CTC (Colour temperature correction)

DMX range Mid point

Value DMX value

Move range

(degrees)

Mode Option

IF CHANNEL 12 (White) = WHITE CTC (Dmx range value 206 - 255)

0-255

Function

43 colour temp. Correction Macros: 0= 2700°K / 128= 4500°K / 255= 6500°K

IF CHANNEL 12 (White) = NO FUNCTION (Dmx range value 0 - 43)

0-255 Smooth RGBW linear Hue correction

DMX CHANNEL 14 Parameter: COLOUR MACROS

IF:

MENU Up-Down

ENTER

Up-Down

DMX range

Value

0-14

15-29

30-44

45-59

60-74

75-89

90-104

105-119

120-134

135-149

150-164

165-179

180-194

195-209

210-225

226-239

240-255

Mid point

DMX value

Move range

(degrees)

ENTER Up-Down

Mode

ENTER

PLEASE CHECK PAGE 12

Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 16

31

DELTA 12

DMX CHANNEL 14 Parameter: COLOUR MACROS

IF:

MENU Up-Down

111-118

119-126

127-134

135-142

143-150

151-158

159-166

167-174

175-182

183-190

191-198

199-206

207-214

215-222

223-230

231-238

239-246

247-255

DMX range

Value

0-14

15-22

23-30

31-38

39-46

47-54

55-62

63-70

71-78

79-86

87-94

95-102

103-110

DMX CHANNEL

ENTER

Up-Down ENTER

PLEASE CHECK PAGE 12

ENTER Up-Down

Mid point

DMX value

Move range

(degrees)

15

Mode Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 4

Macro 5

Macro 6

Macro 7

Macro 8

Macro 9

Macro 10

Macro 11

Macro 12

Macro 13

Macro 14

Macro 15

Macro 16

Rainbow Speed 1 (1 Sec.)

Rainbow Speed 2 (5 Sec.)

Rainbow Speed 3 (10 Sec.)

Rainbow Speed 4 (20 Sec.)

Rainbow Speed 5 (30 Sec.)

Rainbow Speed 6 (60 Sec.)

Rainbow Speed 7 (120 Sec.)

Rainbow Speed 8 (180 Sec.)

Random Speed 1 (0.5 sec.)

Random Speed 2 (1 Sec.)

Random Speed 3 (2 Sec.)

Random Speed 4 (5 Sec.)

Random Speed 5 (10 Sec.)

Random Speed 6 (30 Sec.)

Parameter: FUNCTIONS (Recall, Create and Store the Custom white)

DMX range Mid point

Value DMX value

0-79

80-160

161-255

Move range Mode Option Function

(degrees)

Custom White Recall (Enable CH 12 for Custom white Recall)

Custom White Create (Enable CH 12 for Custom white Creation)

Custom White Store (Store the Custom White created )

32

DELTA 12

17-DMX PROTOCOL

DELTA 12 CT

10 CHANNELS MODE (Default)

1 SHUTTER

2 DIMMER

3 RED = WHITE 1

4 GREEN = WHITE 2

5 BLUE = WHITE 3

6 AMBER = WHITE 4

7 WHITE (Pre-programmed whites at different colour temperatures)

8 CTC

9 COLOURS MACRO

10 FUNCTIONS

DMX CHANNEL

1 Parameter: SHUTTER

DMX range

Value

0-9

10-19

20-29

30-119

120-149

150-179

180-204

205-229

230-255

Mid point

DMX value

Move range

(degrees)

5

14

24

192

218

240

Mode Option Function

Black-out

Open

Black-out

Open

Pulse open at variable speed from slow to fast (42,6 s - 120 ms)

Pulse close at variable speed from slow to fast (42,6 s - 120 ms)

Strobe at variable speed from slow to fast (3,27 s - 30 ms)

Random Strobe (Master and RGBA active)

Random Strobe (Full)

DMX CHANNEL 2

Parameter: DIMMER

DMX range

Value

0-255

Mid point

DMX value

DMX CHANNEL 3

Move range

(degrees)

Parameter:

Mode

RED = WHITE 1

Option Function

Proportional dimmer

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option Function

Proportional colour

33

DELTA 12

DMX CHANNEL 4

Parameter: GREEN = WHITE 2

DMX range

Value

0-255

DMX CHANNEL

Mid point

DMX value

5

Move range

(degrees)

Parameter:

Mode

BLUE = WHITE 3

Option Function

Proportional colour

DMX range

Value

0-255

DMX CHANNEL

Mid point

DMX value

6

Move range

(degrees)

Parameter:

Mode Option

AMBER = WHITE 4

Function

Proportional colour

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option Function

Proportional colour

DMX CHANNEL

0-55

56-105

106-155

7

23

80

130

Parameter:

DMX range Mid point

Value DMX value

WHITE (Pre-programmed White at diff. color temperature)

Move range

(degrees)

Mode Option Function

No Function

Full (White1-White2-White3-White4 at Full)

White DTS

IF CHANNEL 10 (FUNCTIONS) = CUSTOM WHITE RECALL (Dmx range value 0 - 79)

156-205

206-255

180

225

Custom White Recall

43 color temp. Correction Macros: 2700°K - 6500°K)

IF CHANNEL 10 (FUNCTIONS) = CUSTOM WHITE CREATE (Dmx range value 80 - 160)

156-205 180 Custom White Create (RGBA levels selectable by DMX)

206-255 225 White CTC (Channel 8 CTC enabled

43 color temp. Correction Macros: 2700°K - 6500°K)

34

DMX CHANNEL 8 Parameter:

DMX range Mid point

Value DMX value

Move range

(degrees)

CTC (Colour temperature correction)

Mode Option

IF CHANNEL 7 (White) = WHITE CTC (Dmx range value 206 - 255)

0-255

Function

43 colour temp. Correction Macros: 0= 2700°K / 128= 4500°K / 255= 6500°K

IF CHANNEL 7 (White) = NO FUNCTION (Dmx range value 0 - 43)

0-255 Smooth RGBA linear Hue correction

DMX CHANNEL 9 Parameter: COLOUR MACROS

IF:

MENU Up-Down

ENTER

Up-Down

DMX range

Value

0-14

15-29

30-44

45-59

60-74

75-89

90-104

105-119

120-134

135-149

150-164

165-179

180-194

195-209

210-225

226-239

240-255

Mid point

DMX value

Move range

(degrees)

ENTER Up-Down

Mode

ENTER

PLEASE CHECK PAGE 12

Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 16

35

DELTA 12

DMX CHANNEL 9 Parameter: COLOUR MACROS

IF:

MENU Up-Down

111-118

119-126

127-134

135-142

143-150

151-158

159-166

167-174

175-182

183-190

191-198

199-206

207-214

215-222

223-230

231-238

239-246

247-255

DMX range

Value

0-14

15-22

23-30

31-38

39-46

47-54

55-62

63-70

71-78

79-86

87-94

95-102

103-110

DMX CHANNEL

ENTER

Up-Down ENTER

PLEASE CHECK PAGE 12

ENTER Up-Down

Mid point

DMX value

Move range

(degrees)

10

Mode Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 4

Macro 5

Macro 6

Macro 7

Macro 8

Macro 9

Macro 10

Macro 11

Macro 12

Macro 13

Macro 14

Macro 15

Macro 16

Rainbow Speed 1 (1 Sec.)

Rainbow Speed 2 (5 Sec.)

Rainbow Speed 3 (10 Sec.)

Rainbow Speed 4 (20 Sec.)

Rainbow Speed 5 (30 Sec.)

Rainbow Speed 6 (60 Sec.)

Rainbow Speed 7 (120 Sec.)

Rainbow Speed 8 (180 Sec.)

Random Speed 1 (0.5 sec.)

Random Speed 2 (1 Sec.)

Random Speed 3 (2 Sec.)

Random Speed 4 (5 Sec.)

Random Speed 5 (10 Sec.)

Random Speed 6 (30 Sec.)

Parameter: FUNCTIONS (Recall, Create and Store the Custom white)

DMX range Mid point

Value DMX value

0-79

80-160

161-255

Move range Mode Option Function

(degrees)

Custom White Recall (Enable CH 7 for Custom white Recall)

Custom White Create (Enable CH 7 for Custom white Creation)

Custom White Store (Store the Custom White created )

36

DELTA 12

DELTA 12 CT

6 CHANNELS MODE

1 SHUTTER

2 DIMMER

3 RED = WHITE 1

4 GREEN = WHITE 2

5 BLUE = WHITE 3

6 AMBER = WHITE 4

DMX CHANNEL

1 Parameter: SHUTTER

DMX range

Value

0-9

10-19

20-29

30-119

120-149

150-179

180-204

205-229

230-255

Mid point

DMX value

Move range

(degrees)

5

14

24

192

218

240

Mode Option Function

Black-out

Open

Black-out

Strobe at variable speed from slow to fast (3,27 s - 30 ms)

Pulse open at variable speed from slow to fast (42,6 s - 120 ms)

Pulse close at variable speed from slow to fast (42,6 s - 120 ms)

Open

Random Strobe (Master and RGBA active)

Random Strobe (Full)

DMX CHANNEL

DMX range

Value

0-255

2 Parameter: DIMMER

Mid point

DMX value

Move range

(degrees)

Mode

DMX CHANNEL 3

Parameter: RED = WHITE 1

Option

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option

Function

Proportional dimmer

Function

Proportional colour

37

DELTA 12

DMX CHANNEL 4

Parameter: GREEN = WHITE 2

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option

DMX CHANNEL 5

Parameter: BLUE = WHITE 3

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option

DMX CHANNEL 6

Parameter: AMBER = WHITE 4

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option

Function

Proportional colour

Function

Proportional colour

Function

Proportional colour

38

DELTA 12

DELTA 12 CT

15 CHANNELS MODE

1 SHUTTER

2 DIMMER

3 DIMMER FINE

4 RED = WHITE 1

5 RED FINE = WHITE 1 FINE

6 GREEN = WHITE 2

7 GREEN FINE = WHITE 2 FINE

8 BLUE = WHITE 3

9 BLUE FINE = WHITE 3 FINE

10 AMBER = WHITE 4

11 AMBER FINE = WHITE 4 FINE

12 WHITE (Pre-programmed whites at different colour temperatures)

13 CTC

14 COLOURS MACRO

15 FUNCTIONS

DMX CHANNEL

1 Parameter: SHUTTER

DMX range

Value

0-9

10-19

20-29

30-119

120-149

150-179

180-204

205-229

230-255

Mid point

DMX value

Move range

(degrees)

5

14

24

192

218

240

Mode Option Function

Black-out

Open

Black-out

Open

Pulse open at variable speed from slow to fast (42,6 s - 120 ms)

Pulse close at variable speed from slow to fast (42,6 s - 120 ms)

Strobe at variable speed from slow to fast (3,27 s - 30 ms)

Random Strobe (Master and RGBA active)

Random Strobe (Full)

DMX CHANNEL 2

Parameter: DIMMER

DMX range

Value

0-255

Mid point

DMX value

DMX CHANNEL 3

Move range

(degrees)

Parameter:

Mode

DIMMER FINE

Option Function

Proportional dimmer

DMX range

Value

0-255

Mid point

DMX value

Move range

(degrees)

Mode Option Function

Proportional dimmer

39

DELTA 12

DMX CHANNEL 4

Parameter: RED = WHITE 1

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 5

Parameter:

Mode Option

RED FINE = WHITE 1 FINE

Function

Proportional colour

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 6

Parameter:

Mode Option

GREEN = WHITE 2

Function

Proportional colour

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 7

Parameter:

Mode Option Function

Proportional colour

GREEN FINE = WHITE 2 FINE

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 8

Parameter:

Mode

BLUE = WHITE 3

Option

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

Mode Option

Function

Proportional colour

Function

Proportional colour

DMX CHANNEL 9

Parameter: BLUE FINE = WHITE 3 FINE

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

Mode Option Function

Proportional colour

40

DELTA 12

DMX CHANNEL 10

Parameter: AMBER = WHITE 4

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

DMX CHANNEL 11

Mode Option Function

Proportional colour

Parameter: AMBER FINE = WHITE 4 FINE

DMX range

Value

0 255

Mid point

DM X value

Move range

(degrees)

Mode Option Function

Proportional colour

DMX CHANNEL

DMX range Mid point

Value DMX value

0-55

56-105

106-155

12 Parameter: WHITE (Pre-programmed White at diff. color temperature)

23

80

130

Move range

(degrees)

Mode Option Function

No Function

Full (White1-White2-White3-White4 at Full)

White DTS

IF CHANNEL 15 (FUNCTIONS) = CUSTOM WHITE RECALL (Dmx range value 0 - 79)

156-205

206-255

180

225

Custom White Recall

43 color temp. Correction Macros: 2700°K - 6500°K)

IF CHANNEL 15 (FUNCTIONS) = CUSTOM WHITE CREATE (Dmx range value 80 - 160)

156-205 180 Custom White Create (RGBA levels selectable by DMX)

206-255 225 White CTC (Channel 8 CTC enabled

43 color temp. Correction Macros: 2700°K - 6500°K)

41

DMX CHANNEL 13 Parameter: CTC (Colour temperature correction)

DMX range Mid point

Value DMX value

Move range

(degrees)

Mode Option

IF CHANNEL 12 (White) = WHITE CTC (Dmx range value 206 - 255)

0-255

Function

43 colour temp. Correction Macros: 0= 2700°K / 128= 4500°K / 255= 6500°K

IF CHANNEL 12 (White) = NO FUNCTION (Dmx range value 0 - 43)

0-255 Smooth RGBA linear Hue correction

DMX CHANNEL 14 Parameter: COLOUR MACROS

IF:

MENU Up-Down

ENTER

Up-Down

DMX range

Value

0-14

15-29

30-44

45-59

60-74

75-89

90-104

105-119

120-134

135-149

150-164

165-179

180-194

195-209

210-225

226-239

240-255

Mid point

DMX value

Move range

(degrees)

ENTER Up-Down

Mode

ENTER

PLEASE CHECK PAGE 12

Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 16

42

DELTA 12

DMX CHANNEL 14 Parameter: COLOUR MACROS

IF:

MENU Up-Down

111-118

119-126

127-134

135-142

143-150

151-158

159-166

167-174

175-182

183-190

191-198

199-206

207-214

215-222

223-230

231-238

239-246

247-255

DMX range

Value

0-14

15-22

23-30

31-38

39-46

47-54

55-62

63-70

71-78

79-86

87-94

95-102

103-110

DMX CHANNEL

ENTER

Up-Down ENTER

PLEASE CHECK PAGE 12

ENTER Up-Down

Mid point

DMX value

Move range

(degrees)

15

Mode Option Function

No Function

Macro 1

Macro 2

Macro 3

Macro 4

Macro 5

Macro 6

Macro 7

Macro 8

Macro 9

Macro 10

Macro 11

Macro 12

Macro 13

Macro 14

Macro 15

Macro 16

Rainbow Speed 1 (1 Sec.)

Rainbow Speed 2 (5 Sec.)

Rainbow Speed 3 (10 Sec.)

Rainbow Speed 4 (20 Sec.)

Rainbow Speed 5 (30 Sec.)

Rainbow Speed 6 (60 Sec.)

Rainbow Speed 7 (120 Sec.)

Rainbow Speed 8 (180 Sec.)

Random Speed 1 (0.5 sec.)

Random Speed 2 (1 Sec.)

Random Speed 3 (2 Sec.)

Random Speed 4 (5 Sec.)

Random Speed 5 (10 Sec.)

Random Speed 6 (30 Sec.)

Parameter: FUNCTIONS (Recall, Create and Store the Custom white)

DMX range Mid point

Value DMX value

0-79

80-160

161-255

Move range Mode Option Function

(degrees)

Custom White Recall (Enable CH 12 for Custom white Recall)

Custom White Create (Enable CH 12 for Custom white Creation)

Custom White Store (Store the Custom White created )

NOTES

43

DELTA 12

The information contained in this publication has been carefully prepared and checked.

However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S.. D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits described herein.

MADE IN ITALY

ISO 9001:2008

D.T.S. quality system is certified to the

ISO 9001:2008 standard

D.T.S. products are designed and manufactured at the D.T.S. plants in italy

*0517I213*

0517I213

D.T.S. Illuminazione s.r.l - Via Fagnano Selve 10-12-14 47843 - Misano Adriatico (RN) Italy

Tel. +39 0541 611131 Fax +39 0541 611111 [email protected] www.dts-lighting.it

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Languages