Bosch | FSM-2000 | FSM-2000 Fire Monitoring System

Fire Alarm Systems | FSM-2000 Fire Monitoring System
FSM-2000 Fire Monitoring System
▶ Easy installation and operation
▶ Importing floor plans from AutoCAD
▶ Zoom and pan
▶ Automatic allocation of detection points in floor plan
▶ Comprehensive event logging
▶ Up to four panels with 2000 detection points at
maximum can be connected
▶ Can be connected with FPA‑5000, FPA‑1200,
UEZ 2000 LSN, BZ 500 LSN
▶ Different language versions available
The FSM-2000 Fire Monitoring System is a graphical user
interface for displaying and monitoring small to medium
fire alarm systems with up to 2000 detection points. It is
designed for four panels of the FPA‑5000, FPA‑1200,
UEZ 2000 LSN or BZ 500 LSN at maximum.
Zoom and Pan
These two functions offer a comfortable navigation in the
floor plan. With the zoom function it is possible to
increase or minimize specific areas. With the pan function
the floor plan can be moved in any direction.
Event Logging
Functions
Installation and Operation
In the event log all procedures and actions are recorded.
You can generate statistics, make backups, print the event
log and search according to various criteria.
A wizard guides you through the installation as well as the
configuration in a few steps. Logically arranged graphics
and icons allow to capture events precisely and to initiate
appropriate measures.
Connectivity
Importing Floor Plans of AutoCAD
Language Versions
You can import floor plans of AutoCAD as dwf-file. The
software automatically allocates the detector list of the
fire panel to the floor plan.
The FSM‑2000 Fire Monitoring System is in different
language versions available:
Authorizations
You can set up as many operators as required and classify
them according to their tasks into one of the three
authorization groups: Operator, installer or administrator.
A maximum of two operators can be logged on to the
system at the same time.
You can connect up to 2000 detection points and four
panels to the FSM-2000. It is working with the fire panels
FPA‑5000, FPA‑1200, UEZ 2000 LSN and BZ 500 LSN.
•
•
•
•
•
•
German/English
Spanish/English
Italian/English
Dutch/English
Polish/English
Russian/English
Installation/Configuration Notes
Hardware Preconditions:
• USB port
www.boschsecurity.com
2 | FSM-2000 Fire Monitoring System
•
•
•
•
•
•
CD-ROM
3.5” disk drive
4 COM ports
RAM 1024 MB (server), 512 MB (client)
Hard drive memory of 10 GB
Network card 100 Mbit
Ordering Information
Software Preconditions:
• Windows 2000, Windows XP, Windows 2003 Server
(German and English operating system)
• Internet Explorer version 5.0 or 6.0
• MSDE 2000
• Microsoft IIS 5.0 (Windows 2000, Windows XP),
Microsoft IIS 6.0 (Windows 20003 Server)
Parts Included
Quant.
Component
1
CD for Installation
1
USB-Dongle
1
Floppy-disk with the file Dongle.crp
FSM-2000 Fire Monitoring System DE/EN
Additionally order:
- Interface Converter OVS
- Connection Cable DSUB 9F-9M
- IOS 0020 A 20 mA Communication Module
(FPA‑5000/FPA‑1200) or SM 20 Interface
Module (UEZ 2000 LSN / BZ 500 LSN)
FSM-2000
FSM-2000-ES Fire Monitoring System ES/
EN
Additionally order:
- Interface Converter OVS
- Connection Cable DSUB 9F-9M
- IOS 0020 A 20 mA Communication Module
(FPA‑5000/FPA‑1200) or SM 20 Interface
Module (UEZ 2000 LSN / BZ 500 LSN)
FSM-2000-ES
FSM-2000-IT Fire Monitoring System IT/
EN
Additionally order:
- Interface Converter OVS
- Connection Cable DSUB 9F-9M
- IOS 0020 A 20 mA Communication Module
(FPA‑5000/FPA‑1200) or SM 20 Interface
Module (UEZ 2000 LSN / BZ 500 LSN)
FSM-2000-IT
FSM-2000-NL Fire Monitoring System NL/
EN
Additionally order:
- Interface Converter OVS
- Connection Cable DSUB 9F-9M
- IOS 0020 A 20 mA Communication Module
(FPA‑5000/FPA‑1200) or SM 20 Interface
Module (UEZ 2000 LSN / BZ 500 LSN)
FSM-2000-NL
FSM-2000-PL Fire Monitoring System PL/
EN
Additionally order:
- Interface Converter OVS
- Connection Cable DSUB 9F-9M
- IOS 0020 A 20 mA Communication Module
(FPA‑5000/FPA‑1200) or SM 20 Interface
Module (UEZ 2000 LSN / BZ 500 LSN)
FSM-2000-PL
FSM-2000-RU Fire Monitoring System RU/
EN
Additionally order:
- Interface Converter OVS
- Connection Cable DSUB 9F-9M
- IOS 0020 A 20 mA Communication Module
(FPA‑5000/FPA‑1200) or SM 20 Interface
Module (UEZ 2000 LSN / BZ 500 LSN)
FSM-2000-RU
Accessories
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
© Bosch Security Systems Inc. 2011 | Data subject to change without notice
T6852457483 | Cur: en-US, V6, 11 Apr 2011
IOS 0020 A 20 mA Communication Module
provides one interface each of S20, RS232
and S1
IOS 0020 A
Interface Converter OVS
3002108620
Connection Cable DSUB 9F-9M
DB EK 822 9F-9M
Asia-Pacific:
Represented by
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6258 5511
Fax: +65 6571 2698
apr.securitysystems@bosch.com
www.boschsecurity.asia
Download PDF