Sprinkler Monitoring

Sprinkler Monitoring
Fire Sprinkler Monitoring Product Catalog
Contents
Flow Switches...............................................................................................4
Pressure Switches.........................................................................................8
Tamper and Supervisory Switches...............................................................10
Corrosion Testing.........................................................................................14
Corrosion Treatment....................................................................................15
Nitrogen Generators....................................................................................16
Corrosion Monitoring...................................................................................17
Explosion Proof Devices..............................................................................18
Releasing Panels.........................................................................................20
Notification Appliances................................................................................22
Digital Communicators.................................................................................25
Conventional Detectors................................................................................26
Pull Stations................................................................................................27
Product List.................................................................................................28
Residential Waterflow Switch Applications Drawing......................................32
Dry Pipe Sprinkler System Drawing..............................................................33
Wet Pipe Sprinkler System Drawing.............................................................34
Deluge System Drawing...............................................................................35
2
For more information, please visit www.pottersignal.com
Flow Switches
Potter Electric Signal Company, LLC
Established in 1898, Potter Electric Signal Company has earned a reputation worldwide as an elite
provider of goods and services. Potter produces a wide array of products including fire sprinkler monitoring
systems, electronic fire systems, and vault and safe security systems. With more than 110 years of
sprinkler monitoring experience, Potter is also the trusted source for corrosion testing, monitoring, and
treatment with our comprehensive suite of corrosion solutions.
At Potter, not only do we supply our customers with products that provide real world solutions for their
unique needs, we strive to provide them unequaled service and technical support.
At Potter you will always receive prompt dependable service from our dedicated team of professionals.
Every employee at Potter is committed to providing you, the customer, the peace of mind in knowing that
when you purchase our products, you are providing your customers the very best product available for
the protection of life and property.
Potter is THE Symbol of Protection.
Potter Electric Signal Company, LLC
1609 Park 370 Place
St. Louis, MO 63042
866.572.3005
Fax: 800.768.8377
Tech Support: 866.956.0988
www.pottersignal.com
Canada: 888.882.1833
Fax: 416.741.1822
Asia/Pacific: 65.9682.8998 Fax: 65.6481.2902
Copyright Potter Electric Signal, LLC. All rights reserved.
3
Flow Switches
Visual
switch
activation
Field replaceable
switch/retard
assembly
Two knockouts for access
to separate low and high
voltage wiring chambers
One knockout
factory removed
and covered with
easily removable
plug for faster
installation.
Updated retard
dial for better
accuracy
4
Non-Corrosive Saddle
Bushing eliminates water
to metal contact stopping
the possibility of corrosion
Flow Switches
VSR
Waterflow Alarm Switch
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
0-90 second field replaceable pneumatic retard
450 psi system pressure rated
Synchronized switch action
5-year warranty
Listings: UL, cUL, FM, LPCB, CSFM, NYMEA, and CE
VSR-EU has a 30 second retard and is VdS, EN 12259-5 and LPCB approved
VSR-S
Waterflow Alarm Switch Small Pipe
•
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
0-90 second field replaceable pneumatic retard
300 psi system pressure rated
Two 1/2” KOs for dual voltage applications
1” threaded brass bushing fits pipe sizes 1”-2”
Ideal for both commercial and residential applications.
5-year warranty
Listings: UL, cUL, CSFM, and NYMEA VSR-S EU is EN 12259-5 and LPCB approved
VSR-AT
Waterflow Alarm Switch with Auto Test Feature
•
•
•
•
•
•
•
Performs functional test without discharging water
Conserves water
Eliminates environmental concerns from sprinkler system discharge
Reduces corrosion
Test is initiated by ATC Key switch or any addressable fire panel
Operates on 24 vdc power from fire panel
Listings: UL, cUL, FM
Auto Test Control Plate
•
•
•
•
Initiates Auto Test feature in VSR-AT
Momentary push button test switch
Key switch to enable/disable the push button
LED indicator
5
Flow Switches
VSR-SG/ST
Waterflow Alarm Switch With Union
•
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
0-90 second field replaceable pneumatic retard
175 psi system pressure rated
1” male CPVC fitting or 1” NPT bushing
Fits CPVC pipe sizes 1”, 1 ¼”, 1 ½”, and 2”
Special fitting allows for installation in confined spaces
5-year warranty
Listings: UL, cUL, CSFM, NYMEA, and CE
VSR-C
Waterflow Alarm Switch For Copper Pipe
•
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
0-90 second pneumatic retard
175 psi system pressure rated
Non-corrosive saddle bushing
Two 1/2” KOs for dual voltage applications
Pipe Sizes: 2”, 2 ½”, 3”, 4” for type K, L, and M copper pipe
5-year warranty
Listings: UL, CSFM, and NYBSA
VSR-FE-2
Waterflow Alarm Switch With Electronic Retard
•
•
•
•
•
•
•
•
•
6
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
0-90 second electronic retard
450 psi system pressure rated
Non-corrosive saddle bushing
Two ½” KOs for dual voltage applications
Pipe schedules 10-40 Sizes 2”-8”
5-year warranty
Listings: UL, ULC and FM
Flow Switches
VS-SP
Special Application Waterflow Switch Without Retard
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
250 psi system pressure rated
One SPDT (Form C) contact second set of contacts optional
1” solid brass threaded bushing
Twelve paddles provided for use on plastic, copper, and schedule 40
5-year warranty
Listings: UL, cUL, CSFM, NYBSA, and CE
VSG
Waterflow Alarm Switch For Low Flow
•
•
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
0-90 second electronic retard
450 psi system pressure rated
Non-corrosive saddle bushing
Two 1/2” KOs for dual voltage applications
Pipe Sizes 2”, 2 ½”, 3”, 4”
Operates at 4 GPM, specially designed for water mist systems
5-year warranty
Listings: UL and CSFM
WFSR-F
Pressure Activated Waterflow Alarm Switch With Retard
•
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
0-90 second pneumatic retard
175 psi system pressure rated
½” male NPT fitting
Eliminates the need for retard chambers
Two ½” KOs for dual voltage applications
5-year warranty
Listings: UL, cUL, CSFM, FM, NYMEA, and CE
RD13
Residential Riser
•
•
•
•
•
•
•
Service pressure up to 175 psi
Unit includes VSR-SG
Drain and test valve
Pressure gauge
Service usage, NFPA 13D &13R
Sizes: 1”, 1 ¼”, 1 ½”, 2”
5-year warranty on VSR-SG
7
Pressure Switches
PS Series
Pressure Type Waterflow Alarm/Supervisory Switch
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
Pressure range: 4-15 psi (PS10), 10-60 psi (PS40), 25-175 psi (PS120)
300 psi system pressure rated
½” male NPT fitting
Two ½” knockouts for dual voltage applications
Separate isolated wiring chambers eliminate NEC questions regarding multi-voltage applications
Factory set for operation at:
- PS10 Pressure Increase at 6 psi, Pressure Decrease at 5 psi
- PS40-1 Pressure Decrease at 30 psi
- PS40-2 Pressure Increase at 50 psi, Pressure Decrease at 30 psi
- PS120-1 Pressure Decrease at 110 psi
- PS120-2 Pressure Increase at 130 psi, Pressure Decrease at 110 psi
• 5-year warranty
• Listings: UL, cUL, CSFM, FM, LPC, NYMEA, and CE
‘VdS’ is listed with UL, FM, VdS, CUL, LPCB, and CSFM
Two 1/2” knockouts for
dual high/low voltage
functions or in/out wiring
Single captive
tamper-proof screw for
quick access and easy
installation
Complies with NEC 760.55
Compact design for easy installation in tight spaces
and rain-lip for protection against the elements
Separate wiring chambers
creating the only NEC 760.55
code compliant pressure switch
in the industry
8
Pressure Switches
PS-TM Series
Completely Pre-Assembled Low Pressure Test Module
• For use on dry pipe and pre-action systems
• Available with PS40-2 or PS15-2 for low pressure systems
• Includes pressure switch, BVL bleeder valve, and easy to
read, high quality, pressure gauge pre-assembled with galvanized
pipe
• Meets the requirement of NFPA 72, 2010, 17.16.2.2 and NFPA 25,
2011, 13.4.4.2.6
• Eliminates accidental tripping of the dry pipe valve during testing
• Saves time and money on inspections and testing
PS100
Pressure Drop Type Waterflow Alarm/Switch
•
•
•
•
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Factory installed neoprene gasket
300 psi system pressure rated
Pressure range 25-175 psi
½” male NPT fitting
Two ½” knockouts for dual voltage applications
Separate isolated wiring chambers eliminate NEC questions regarding
multi-voltage applications
Factory set for operation at 90 psi on pressure decrease
5-year warranty
Listings: UL, ULC, CSFM, FM, LPC, NYMEA, and CE
Typically used on excess pressure systems
BVL
Lever Type Bleeder Valve
• For use as a test valve for supervisory pressure switches on wet pipe
sprinkler systems that have excess pressure and dry pipe sprinkler
systems
• Should be installed in-line with pressure switch and gauge
• Convenient means for removal or testing the pressure actuated
device without affecting the pressure in the system
• ½” NPT connections
PCS/ADPS
Pump Control Switch/Adjustable Deadband Pressure Switch
•
•
•
•
•
Independent set and reset points
Adjustable operating range 25-300 PSIG
12 PSI minimum deadband
NEMA 4X enclosure for indoor or outdoor use
Ambient/media temperature range:
PCS: 40°F to 140°F (4.5°C to 60°C)
ADPS: -4°F to 180°F (-20°C to 82°C)
• Listings: UL, CE, and CSA
9
Tamper Switches
OSYSU-1 & 2
Outside Screw & Yoke Valve Supervisory Switch
•
•
•
•
•
•
•
•
•
NEMA 6P (Submersible)
Factory installed neoprene gasket
OSYSU-1: One set of SPDT (Form C)
OSYSU-2: Two sets of SPDT (Form C)
Fits 1/2”-12” valves
Fully adjustable stainless steel trip rod cuts installation time by 75%
Installs on OS&Y valves in any position
5-year warranty
Listings: UL, cUL CSFM, FM, NYMEA, and CE
The length of the trip lever can be
easily adjusted by simply loosening
the trip lever screw
The serrated surface of the mounting bracket helps prevent
the device from slipping while tightening the carriage bolts.
The white indicator visible through a
window aids in initially locating the
switch on the valve yoke.
Final adjustment can be made by loosening the mounting
screws and using the fine adjustment feature.
10
Tamper Switches
PCVS-2
Control Valve Supervisory Switch
•
•
•
•
•
•
•
•
NEMA 6P (Submersible)
Factory installed neoprene gasket
PCVS-2: Two sets of SPDT (Form C)
1/2” male NPT fitting
Fully adjustable stainless steel trip rod
Installs on wall and post indicator valves, butterfly valves in any position
5-year warranty
Listings: UL, cUL, CSFM, FM, NYMEA, and CE
OSYSU-2 CRH
Outside Screw & Yoke Valve Supervisory Switch with
Corrosion Resistant Hardware
• The OSYSU-CRH provides additional corrosion protection on top of
the NEMA 4X enclosure with corrosion resistant mounting hardware.
PCVS-2 CRH
Control Valve Supervisory Switch with Corrosion Resistant
Hardware
• The PCVS-CRH provides additional corrosion protection on top of the
NEMA 4X enclosure with corrosion resistant mounting hardware.
11
Tamper Switches
PTS-C
Plug Type Supervisory Switch
•
•
•
•
•
•
•
•
•
NEMA 6P submersible
Factory installed neoprene gasket
SPDT contacts 100mA at 28 VDC/AC, 250mA at 12 VDC/AC
SPDT cover tamper 250mA at 28 VDC/AC
Dimensions 7”L x 3.75”W x 3”D (including bracket)
Temperature rating -40°F to 140°F
5-year warranty
Listings: UL, cUL, FM, NYMEA, and CSFM
For non-rising stem valves and other special applications
WLS
Tank Water Level
•
•
•
•
•
•
•
NEMA 4 solid metal enclosure
Detection range before 3” rise/ before 3” fall of water level
Detection of 12” drop in water level
Maximum pressure 175 psi Used on steel or wooden tanks
Works on pressure or gravity tanks
Listings: UL, NYMEA, and CSFM
RTS-O/C
Room Temperature Switch
• Designed to warn of potential sprinkler pipe freezing or other cold
detection applications
• White ABS enclosure
• Epoxy sealed stainless steel case, bimetallic operating mechanism
sensor
• Silver clad contacts • RTS-O: Normally Open
• RTS-C: Normally Closed
• Temperature setting: 40°F ±5°F, 5°C ±3°C
• UL and cUL listed for fire sprinkler supervisory service
12
Tamper Switches
RBVS
Retrofit Ball Valve Switch
Valve shown for reference only.
•
•
•
•
•
•
•
•
•
Monitors alarm line ball valves
Perfect for backflow preventers 1” - 2”
Mounts on standard & “T” style valves
NEMA 4 rated enclosure for indoor and outdoor use
Fits virtually any 1/2” - 2” ball valve
Optional cover tamper switch
US Patent 6,945,509
Meets NFPA requirements 13, 2010, 18.17.1 and IBC/IFC 2009, 903.4
Listings: UL, cUL, NYMEA, and FM Approved
WCS
Water Column Switch
•
•
•
•
•
•
•
•
Used for Dry Pipe/Pre-action systems
Detects presence of water above clapper
NEMA 1 rated enclosure for indoor use
175 psi maximum pressure
SPDT 10 Amps at 120 VAC, 2.0 Amps at 30 VDC resistive
Automatic reset
Patent pending
Listing: UL
TTS
Tank Temperature Switch
•
•
•
•
NEMA 4 enclosure
Operates at 40°F and 140°F
Available for steel or wood tanks
Listings: UL, FM, CSFM, and MEA
13
Corrosion Testing
Bac-Pak
• Easy do-it-yourself test
• Tests for the three most common MIC causing bacteria
• Water in vial changes to color of lid, if bacteria present
Water Test Kit
•
•
•
•
Complete MIC analysis through water sample
Kit comes with prepaid return envelope for analysis
Complies with NFPA 13, requiring MIC testing of the water supply
Detailed report of findings is issued within 2 weeks
Dissolved Iron Water Test Kit
• Monitors the effectiveness of corrosion mitigation programs
• Keeps track of general corrosion within a fire sprinkler system
• Degree of “Redness” of sampled water indicates level of dissolved
iron
5-Year Deposit/Sludge Test Kit
• Designed to conform to the requirements of NFPA 25 requiring testing for MIC if slime or tubercles are discovered during an internal
inspection
• Kit comes with prepaid return envelope for analysis
• Detailed report of findings is issued within 2 weeks
14
Corrosion Treatment
Potter Pipe-Shield®
Corrosion Inhibitor
• Patent pending, biostatic, environmentally friendly corrosion inhibitor
• Available in 5, 15, 55 and 275 gallon sizes
• Developed to protect wet, dry, and pre-action fire sprinkler systems
from MIC (Microbiologically Influenced Corrosion) and oxygen corrosion
• Non-regulated, non-hazardous and completely biodegradable with a
neutral pH
PCIS-B
Portable Chemical Injection System
•
•
•
•
•
Fully self-contained portable version of the PCDS
Durable shipping container
Can be shipped via normal carrier service
Pumps directly from chemical container into system
Weighs only 48 lbs
PCDS-B
Potter Chemical Delivery System
• Metered dosing of corrosion inhibiting treatment fluid
• Cabinet can house two (2) 15 gallon containers of Pipe-Shield
• Optional secondary containment tank prevents chemical spills
CDP
Corrosion Dry Air Pak
•
•
•
•
•
•
•
•
Delivers moisture free air with a dew point of -40°F
Completely pre-assembled
UL/FM air maintenance device included
Fully integrated control panel
Hour meter
Oversized mufflers
30 gallon receiver
Single and three phase versions
15
Nitrogen Generators
Potter Nitrogen Generators
•
•
•
•
•
Slows oxygen corrosion
Ultra low dew point
Convenient, on demand generation of nitrogen
Environmentally friendly
Simple installation
NGP-SPV
Self-Purging Valve
• Displaces corrosive oxygen from the system
• Ensures high purity nitrogen is equally distributed throughout the
system
• Delivers up to 99% nitrogen throughout all branch lines
• Provides a location to monitor nitrogen purity
NGP-SPV AUTO
Automatic Self-Purging Valve
• Potter self-purging valve with automatic valve and programmable
control
• Automatically closes when the purging process is complete
• Helps extend the life of the nitrogen generator
• Can be programmed for cyclic purging
16
Corrosion Monitoring
PAAR-B
Potter Automatic Air Release (Patented)
•
•
•
•
•
•
•
Helps eliminate air/water interface line where corrosion often thrives
Mechanical fail safe Water Shutoff Valve
Electrically supervised Water Shutoff Valve
Visual indication of Water Shutoff Valve operation
Prevents damage from water spray, drips, or leaks from air vent
Complete unit ready to install at high points in the sprinkler system
UL listed and FM approved air vent for use on fire sprinkler branch
lines
PAV
Potter Air Vent
• Provides automatic venting of trapped air in fire sprinkler systems
• Limits oxygen corrosion when placed at the high point(s) of the
systems
• UL listed and FM approved air vent for use on fire sprinkler branch
lines
PCMPK
Probe Assembly with PS10-1
• Used in conjunction with any corrosion monitoring station or as a
•
•
•
•
stand alone corrosion monitoring probe
Pressure switch trips when corrosion affects probe
Provides notification when coupons need replacement
Patent pending
Probe simulates 5 years of allowable pipe loss in schedule 10 pipe
(FM Data Sheet 2-1)
PCMS-RM
Potter Corrosion Monitoring Station Riser Mount
•
•
•
•
•
•
•
•
•
•
•
For wet or dry systems
Installs on riser for easy access
3 outlets for coupons and probe
Sight glass to view internal conditions
Air inlet valve
Includes one steel and one brass coupon
Shown with optional PCMPK installed
Patent pending
Ships assembled
250 PSI rated
Allows for inspections and samples without disabling sprinkler system
17
Explosion Proof Devices
PIVS-U-EX
Explosion Proof Post Indicator Valve Switch
•
•
•
•
•
Installs on post indicator valves and butterfly valves
½” mounting nipple
Contact rating: 15 AMPS at 125 VAC, 1/2 AMP at 125 VDC
-40° to 140°F
UL listed enclosure NEMA 1, 7, 9
OSYS-U-EX
Explosion Proof OS & Y Switch - Universal
•
•
•
•
Installs on OS & Y valves ½”-2”
Contact rating: 15 Amps at 125 VAC, 1/2 Amp at 125 VDC
-40° to 140°F
UL listed enclosure NEMA 1, 7, 9
OSYSU-EX-O
Outdoor Explosion Proof OS & Y Switch
•
•
•
•
•
Installs on OS & Y valves ½”-2”
Contact rating: 15 Amps at 125 VAC, 1/2 Amp at 125 VDC
-13°F to 140°F
UL listed enclosure NEMA 1, 3, 4, 4X, 6, 6P, and 13
Water tight, dust tight, and corrosion resistant for outdoor use
VSR-FEX
Explosion Proof Vane Type Waterflow Switch
•
•
•
•
•
•
•
•
NEMA 4 and 9 solid metal enclosure
0-90 second pneumatic retard
450 psi system pressure rated
Non-corrosive saddle bushing
Two ½” threaded connections for conduit
Pipe schedules 10-40 sizes 2”-8”
1-year warranty
Listings: UL, cUL, CSFM, ATEX, and FM
PS10-EX and PS40-EX
Explosion Proof Pressure Switches
18
•
•
•
•
•
•
•
•
•
•
•
NEMA 4 and 9 solid metal enclosure
250 psi system rated pressure
½” NPT male brass fitting
PS10-EX set for operation at:
• Two switches operate on pressure increase at 6 psi
• Two switches operate on pressure decrease at 5 psi
PS40-EX set for operation at:
• One switch operates on pressure decrease at 30 psi
• Second switch operates on pressure increase at 50 psi
1-year warranty
Listings: UL, cUL, CSFM, FM, NYMEA, and ATEX
Explosion Proof Devices
FSEX-24 PMR
Explosion Proof Strobe
•
•
•
•
•
24 VDC
Corrosion resistant housing
Indoor or outdoor mounting
Polarized
Listings: UL, CSFM and MEA approved
FHEX-24 SMR
Explosion Proof Horn
•
•
•
•
24 VDC
Heavy duty, copper free cast aluminum housing
NEMA 4X, IP66 enclosure
Listings: UL and cUL
YL6
Explosion Proof Horn/Strobe
•
•
•
•
•
•
24 VDC
Low current draw
Aluminum enclosure
Flash rate of one per second
110 dB at one meter sounder
Listings: UL and cUL
RMS-6T-EXP-WP
Explosion Proof Pull Station
•
•
•
•
•
•
•
Marine & NEMA 4X rated
Weather proof
ADA compliant
Allen Key reset
DPDT switch
Screw terminal connections
Listings: UL, FM, CSFM, and NYMEA
19
Releasing Panels
PFC-4410RC
Water or Agent Extinguishing Panel
•
•
•
•
•
•
•
•
•
•
•
•
4 Class B programmable initiating zones and outputs
Compatible with up to 10,000’ of Linear Heat Detection per zone
2 dedicated Class B supervisory zones
32 character LCD display, 34 LED display
20 pre-configured programs
On-board programming
40 event history buffer
Single or double interlock
Single or dual hazard
Alarm, trouble, supervisory, and waterflow relays standard
1 abort circuit
Listings: UL, ULC, FM, CSFM, and NYMEA
PFC-6075R
Addressable Releasing Panel
•
•
•
•
•
•
•
•
•
•
•
•
Built in SLC capable of supporting 75 Potter/Nohmi protocol devices
5.0 Amp 24vdc Power Supply
2 NACs each rated at 3.0 Amps max
2 I/O Circuits each rated at 1.0 Amps max
Listed for manual release abort or release circuit
Support for all major synchronization patterns
Built-in Ethernet port for programming and network connectivity
Built-in email support for system status and event information
P-Link RS-485 bus supports system accessories
1,000 event non-volatile history buffer
Listed with pre-action, deluge, and agent systems
UL listed, CSFM, NYC Fire Department Certificate of Approval
RA-6075R
LCD Annunciator
•
•
•
•
•
Used with PFC-6075R
32 character LCD display
Compact metal box with key lock
Identical keypad to PFC-6075R
Provides Release and Pre-Release LED’s to indicate releasing status
MAS
Manual Pull/Abort Station Combination
20
•
•
•
•
•
•
•
•
Perfect for agent suppression systems
UL, cUL Listed, FM Approved
No disassembly required
Plate mounts to box with just 2 screws
Backbox included
Optional flush mount plate
Standard with Red or Yellow agent release pull stations
Available without pull station installed for use with RMS series stations
Releasing Panels
Abort Switch
•
•
•
•
•
MRS
Main/Reserve Switch
One N.O. momentary contact
5 Amps @ 24 VDC (10 mA minimum)
Indoor use only
Listings: UL and cUL
Available with blue button for Canada
RCDS-1
• For agent suppression systems when uninterrupted protection is required
• Complies with NFPA 12, 12A, 17,
and 2001
• Provides visual indication of
connection to Main or Reserve supply
• Key protected with key removable in either position
Releasing Circuit Disable Switch
•
•
•
•
•
•
•
•
•
One N.O. key operated switch
4 Amps @ 120/240 VAC 2.5 Amps @ 125 VAC
24 VDC 50 mA
Indoor use only
Creates supervisory condition on associated release panel
Replaces software controlled disconnect
Temperature range -22°F to 140°F (-30°C to 60°C)
Complies with NFPA 72 requirements
Listings: UL and cUL
RA-4410RC
Remote Annunciator
•
•
•
•
•
•
Up to 4 annunciators can be connected to each PFC-4410RC
Rotary switches on panel and annunciator to supervise
Trouble/Supervisory buzzer
Separate LED’s for various alarms
Lamp test/buzzer silence switch
Listings: UL, cUL, CSFM, FM, and MEA
ARM-44 Relay Module
•
•
•
•
Provides 8 Form C relay outputs
Selectable latching or common setting
Multiple operating modes
Listings: UL, cUL, CSFM, FM, and MEA when used in conjunction
with the PFC-4410RC
Arm 1 & Arm 2
Auxiliary Relay Modules
•
•
•
•
•
•
40mA at 24 VDC
10 amps resistive
120/240 VAC, 0-30 VDC
4 DPDT contacts (ARM-1)
DPDT contacts (ARM-2)
Listings: UL (PFC-4410RC), FM (PFC-4410RC)—ARM-2 only
21
Notification Appliances
Remote Mini-Horn
MH Series
•
•
•
•
•
•
Terminal/4-wire models
Sound output 97dB
Single gang plate
12-24 VDC and 120 VAC
15 mA current draw
Listings: UL and ULC
Electronic Horn
EH 24 Series
•
•
•
•
•
•
•
Red or white
Chime, whoop, mechanical, or 2400HZ sound output
Indoor/outdoor listed (with weatherproof back box)
Pre-wire back plate
Universal back plate mounting
Listings: UL and CSFM
Surface back box available
Selectable Candela Strobe &
Strobe/Horn
S-24 & HS-24
•
•
•
•
•
•
•
22
24 VDC with 15, 30, 60, 75, or 110 cd settings
5 candela settings per device
Sound output settings including chime
Candela selection view window
Pre-wire back plate
Low current draw
Listings: UL, ADA and CSFM
Notification Appliances
Remote Mini-Horn
HP-25 Series
•
•
•
•
•
•
•
Terminal/4-wire models
Sound output 97dB
Single gang plate
12-24 VDC
15 mA current draw
Temporal and non-temporal patterns
Listings: UL and ULC
Ceiling Strobe & Strobe/Horn
CS & CHS
•
•
•
•
•
•
•
•
Selectable 15, 30, 75, 95, 115, or 150 candela
Low current draw
24 VDC input
Pre-wire back plate
High/low dB
Designed for wall and ceiling mount
Surface mount CLNG-BB
Listings: UL, CSFM, MEA, ADA
Outdoor Strobe & Strobe/Horn
SLP & HSLP
•
•
•
•
•
•
•
12 VDC with 15, 35, or 60 cd setting
24 VDC with 15, 35, 60, 75, 95, or 110 cd setting
6 candela settings per device with selection view window
33 sound output settings
15/75 ADA compliant on 60 cd setting
Pre-wire back plate with universal back plate mounting
Listings: UL and cUL
23
Notification Appliances
Weatherproof
Select-A-Strobe/Horn®
SH-120 Series
•
•
•
•
•
•
120 VAC operation Low current draw
6 sound output settings
Indoor and outdoor use
Includes BBX-5 backbox
Listings: UL and CSFM
SASH Series
Select-A-Strobe/Horn®/Sign
•
•
•
•
•
•
SASH-12/24 VDC SASH-120, 115 VAC
90dBA at 10 ft.
Indoor and outdoor use
Weatherproof backbox included with both models
UL Listed Strobe/Horn
Sync Module
AVSM
•
•
•
•
•
Operates with S-24, HS-24, CS, and CHS series
Synchronize horn and strobe with the use of only two wires
No limit to the number of modules that can be synchronized together
Rated for 3 amps continuous current and 5 amps surge
Synchronizes to 1Hz flash rate
Bells
PBA-AC & MBA-DC
24
•
•
•
•
•
Red powder coating finish
Sizes available: 6”, 8”, 10”
Available voltage: 24 VAC, 120 VAC, 12 VDC, 24 VDC
Service Use: fire alarm, general signal, burglar alarm
Environment: -40° to 150°F, indoor or outdoor use (outdoor use
requires weatherproof backbox BBK-1)
• 5-year warranty
• Listings: UL, ULC (MBA bells only), CSFM, and MEA
Digital Communicators
PFC-6006
Sprinkler Monitoring Panel
•
•
•
•
•
•
•
Built-in IP and Dual line DACT communications
6 programmable initiating device circuits (1 class A and 5 class B)
2 wire smoke detector capability
0.5 amp NAC circuit, 0.5 amp Aux Power circuit
Email capabilities for events and reminders
Quadrasync support
Listings: UL, cUL, and CSFM
RA-6006 (Canada Only)
LCD Annunciator
•
•
•
•
32 character LCD display
Communicates using RS-485 connection
Used on the PFC-6006 Sprinkler Monitoring Panel
Up to 4 can be connected using Class B wiring
RA-6075
LCD Annunciator
•
•
•
•
32 character LCD display
Communicates using RS-485 connection
Used on any PFC-6000 Panel
Connect up to 31 to each P-Link Circuit
25
Conventional Detectors
PS-24
Photoelectric Smoke Detector
•
•
•
•
•
•
•
•
•
Low profile 1.8”
2 or 4 wire base
Sounder & relay base available
2 built-in power alarm LEDs
With or without magnetic test (MRI Rooms)
Vandal resistant locking feature
Test feature
Base not included
Listings: UL, ULC, CSFM and FM
BPS Series
Baseless Smoke Residential
•
•
•
•
•
•
•
12 or 24 VDC
BPS-2, 2 wire baseless photo electric smoke
BPS-4, 4 wire baseless photo electric smoke
White or eggshell color
With heat available
Base not included
Listings: UL, ULC, CSFM and FM
PS-24H
Photoelectric Smoke/Heat Detector
•
•
•
•
•
•
•
135°F self-restoring fixed temperature
Low profile 1.8”
Built-in power alarm LED
Vandal resistant locking base
Test feature
Base not included
Listings: UL, ULC, CSFM and FM
Heat Detector
CR-135W, CF-135W, CR-200W, CF-200W
•
•
•
•
Available in 135°F and 200°F fixed temperature or with rate of rise
Rate of rise responds to rise in temperature of approximately 15°F/min
Other models available upon request
Listings: UL, ULC, CSFM and FM
Duct Detector
DSD Series
26
•
•
•
•
•
Photoelectric DSD-P
Powered by 115 VAC, 24 VAC or 24 VDC
(2) 10A Form C alarm contacts
Wide variety of remote accessories
WP-1 enclosure provides outdoor installations against rain, sleet, and snow
• Comes with sampling tubes
• Listings: UL and CSFM
Sampling Tubes
• STS-2.5 duct sampling tube
• STS-5.0 duct sampling tube
• STS-10 duct sampling tube
Pull Stations
Fire Pull Station
P32-1T Series*
•
•
•
•
•
•
•
•
•
•
Single or dual contact
Terminal connections
Allen Key reset
Standard single gang mounting
10 Amp snap action switch
Optional auxiliary relay contacts
High gloss red enamel finish
*Canadian Model: P32-1TS
Glass breakrod
Surface back boxes available
Listings: UL, ULC, ADA, CSFM and FM
Dual Action
P32-1T-LP
•
•
•
•
•
•
•
•
•
Single contact
Allen Key reset
Standard single gang mounting
10 Amp snap action switch
Optional auxiliary relay contacts
High gloss red enamel finish
Glass breakrod
Surface and weatherproof back boxes available
Listings: UL, ULC, ADA, CSFM and FM
Special Application
Pull Stations
• Colors available: Black, blue, green, grey, orange, •
•
•
•
•
•
•
•
•
purple, red, white or yellow
Single or dual action, single or double contact
Terminal connectors
Glass breakrod
10 Amp snap action switch
Brass or chrome plating
Custom labeling in any language
Weatherproof and explosion proof models available
Made in the U.S.A.
Listings: UL, ULC, ADA, CSFM, FM and MEA
Weatherproof
RMS-1T-WP
•
•
•
•
•
•
•
•
•
Single or dual action
Optional key reset
Weatherproof back box included
10 Amp snap action switch
Optional auxiliary relay contacts
High gloss red enamel finish
Glass breakrod
Single or double contact
Listings: UL, ULC, ADA, CSFM and FM
27
Product List
Flow Switches
Pressure Switches & Peripherals
Stock #
Model #
Description
Stock #
Model #
Description
1144402
VSR-2
Waterflow alarm switch for 2” pipe
1340103
PS10-1
1144425
VSR-2½
Waterflow alarm switch for 2 ½” pipe
Pressure type waterflow alarm and supervisory
switch one contact
1144403
VSR-3
Waterflow alarm switch for 3” pipe
1340104
PS10-2
Pressure type waterflow alarm and supervisory
switch two contacts
1340403
PS40-1
High/low pressure switch one contact
1340404
PS40-2
High/low pressure switch two contacts
1119100
PS40-TM
Completely pre-assembled low pressure test module
1119101
PS15-TM
Completely pre-assembled low pressure test module
1341005
PS100-2
Pressure type waterflow alarm and supervisory
switch two contacts
1144435
VSR-3½
Waterflow alarm switch for 3 ½” pipe
1144404
VSR-4
Waterflow alarm switch for 4” pipe
1144405
VSR-5
Waterflow alarm switch for 5” pipe
1144406
VSR-6
Waterflow alarm switch for 6” pipe
1144408
VSR-8
Waterflow alarm switch for 8” pipe
1144410
VSR-10
Waterflow alarm switch for 10” pipe
1144440
VSR-S
Waterflow alarm switch for 1” thru 2” pipe
1341203
PS120-1
High/low pressure switch one contact
1144460
VSR-SG
Waterflow alarm switch with union for 1” thru 2” pipe
1341204
PS120-2
High/low pressure switch two contacts
1000018
BVL
Lever type bleeder valve
1144461
VSR-SG w/
TSK
Waterflow alarm switch with union and tamper
switch for 1” thru 2” pipe
1370080
PCS
Pump control switch
1144465
VSR-ST
Waterflow alarm switch with threaded union for 1”
thru 2” pipe
1370010
ADPS-300-1B
Adjustable deadband pressure switch w/ brass
connection
1144466
VSR-ST w/
TSK
Waterflow alarm switch with threaded union and
tamper switch for 1” thru 2” pipe
1370020
ADPS-300-1S
Adjustable deadband pressure switch w/ stainless
steel connection
1370030
ADPS-300-2S
Adjustable deadband pressure switch w/ stainless
steel connection
1370040
ADPS-600-1B
Adjustable deadband pressure switch w/ brass
connection
1370050
ADPS-600-1S
Adjustable deadband pressure switch w/ stainless
steel connection
1370060
ADPS-600-2S
Adjustable deadband pressure switch w/ stainless
steel connection
1144450
VSR-C-2
Waterflow alarm switch for 2” copper pipe
1144451
VSR-C-2½
Waterflow alarm switch for 2 ½” copper pipe
1144452
VSR-C-3
Waterflow alarm switch for 3” copper pipe
1144453
VSR-C-4
Waterflow alarm switch for 4” copper pipe
1029030
Replacement retard for waterflow alarm switch
1116002
VSR-FE2-2
Waterflow alarm switch with electronic retard 2” pipe
1116025
VSR-FE2-2½
Waterflow alarm switch with electronic retard 2½” pipe
1116003
VSR-FE2-3
Waterflow alarm switch with electronic retard 3” pipe
Tamper & Supervisory Switches
1116035
VSR-FE2-3½
Waterflow alarm switch with electronic retard 3½” pipe
1116004
VSR-FE2-4
Waterflow alarm switch with electronic retard 4” pipe
Stock #
Model #
Description
1116005
VSR-FE2-5
Waterflow alarm switch with electronic retard 5” pipe
1010201
PTS-C
Plug type supervisory switch
1116006
VSR-FE2-6
Waterflow alarm switch with electronic retard 6” pipe
1010117
WLS
Tank water level switch
1116008
VSR-FE2-8
Waterflow alarm switch with electronic retard 8” pipe
1010108
RTS-O
Room temperature switch normally open
1111100
VS-SP
Special application waterflow switch without retard
1010109
RTS-C
Room temperature switch normally closed
1116051
VSG-2½
Waterflow alarm switch for low flow 2 ½” (73 mm)
pipe
1010040
TTS-S
Tank temperature switch for steel tank
1010041
TTS-W
Tank temperature switch for wood tank
1010102
OSYSU-1
Outside screw & yoke valve supervisory switch one
contact
1010202
OSYSU-2
Outside screw & yoke valve supervisory switch two
contacts
1010210
OSYSU-2 CRH
Ouside screw & yoke valve supervisory switch two
contacts with Corrosion Resistant Hardware
1116052
VSG-2½
Waterflow alarm switch for low flow 2 ½” (76.1 mm)
pipe
1010080
WFSR-F
Pressure activated waterflow alarm switch with
retard
1119067
RD13-1
Residential riser without check valve for 1” pipe
1119077
RD13-1.25
Residential riser without check valve for 1 ¼” pipe
1119087
RD13-1.50
Residential riser without check valve for 1 ½” pipe
1010203
PCVS-2
Control valve supervisory switch two contacts
1119097
RD13-2
Residential riser without check valve for 2” pipe
1010211
PCVS-2 CRH
Control valve supervisory switch two contacts with
Corrosion Resistant Hardware
1000040
RBVS
Retrofit ball valve switch
1000035
RBVS-T
Retrofit ball valve switch with tamper switch
1010118
WCS-1/2
Water column switch 1/2”
1010119
WCS-3/4
Water column switch 3/4”
28
Product List
Corrosion Solutions
1119406
NGP-750M1-2A
Nitrogen Generator 208V Single Phase
1119407
NGP-750M1-3A
Nitrogen Generator 230V Single Phase
1119408
NGP-750M1-2B
Nitrogen Generator 208V Three Phase
1119409
NGP-750M1-3B
Nitrogen Generator 230V Three Phase
Stock #
Model #
Description
1119172
BAC-PAK
Do-it-yourself test kit for most common water
bacteria
1119176
Iron Kit
Dissolved iron water test kit
1119178
WTK
Water test kit
1119174
Sludge Kit
5 year deposit sludge test kit
1119546
PCMS-RM
Corrosion monitoring station riser mount
1119410
PCMPK-1
Corrosion monitoring probe kit riser mount & dry
pipe models
NGP-750M1-4B
Nitrogen Generator 460V Three Phase
0090180
1119411
PCMPK-2
Corrosion monitoring probe kit older style ceiling
mount models
NGP-1100M1-2A
Nitrogen Generator 208V Single Phase
0090181
1119412
Nitrogen Generator 230V Single Phase
1030001
PAAR-B
Automatic air release
NGP-1100M1-3A
1119720
PAV
Air vent
1119413
NGP-1100M1-2B
Nitrogen Generator 208V Three Phase
1119414
NGP-1100M1-3B
Nitrogen Generator 230V Three Phase
1119415
NGP-1100M1-4B
Nitrogen Generator 460V Three Phase
1119416
NGP-1100M2-2A
Nitrogen Generator 208V Single Phase
1119417
NGP-1100M2-3A
Nitrogen Generator 230V Single Phase
1119418
NGP-1100M2-2B
Nitrogen Generator 208V Three Phase
1119419
NGP-1100M2-3B
Nitrogen Generator 230V Three Phase
1119420
NGP-1100M2-4B
Nitrogen Generator 460V Three Phase
1119421
NGP-1275M1-2A
Nitrogen Generator 208V Single Phase
1119422
NGP-1275M1-3A
Nitrogen Generator 230V Single Phase
1119423
NGP-1275M1-2B
Nitrogen Generator 208V Three Phase
1119424
NGP-1275M1-3B
Nitrogen Generator 230V Three Phase
1119425
NGP-1275M1-4B
Nitrogen Generator 460V Three Phase
1119426
NGP-1275M2-2A
Nitrogen Generator 208V Single Phase
1119427
NGP-1275M2-3A
Nitrogen Generator 230V Single Phase
1119428
NGP-1275M2-2B
Nitrogen Generator 208V Three Phase
1119429
NGP-1275M2-3B
Nitrogen Generator 230V Three Phase
1119430
NGP-1275M2-4B
Nitrogen Generator 460V Three Phase
1119431
NGP-1275M3-2A
Nitrogen Generator 208V Single Phase
1119105
5 gal Pipe-Shield™ corrosion inhibitor
1119115
15 gal Pipe-Shield™ corrosion inhibitor
1119155
55 gal Pipe-Shield™ corrosion inhibitor
1119275
275 gal Pipe-Shield corrosion inhibitor
™
1119925
PCIS-B
Portable chemical injection system
1119703
PCDS-B
Chemical delivery system
1119726
CDP-500
Corrosion dry pak single phase 120V
1119727
CDP-500
Corrosion dry pak single phase 208V
1119728
CDP-500
Corrosion dry pak single phase 230V
1119730
CDP-500
Corrosion dry pak three phase 208V
1119731
CDP-500
Corrosion dry pak three phase 230V
1119732
CDP-500
Corrosion dry pak three phase 460V
1119733
CDP-500
Corrosion dry pak three phase 575V
1119735
CDP-1000
Corrosion dry pak three phase 208V
1119736
CDP-1000
Corrosion dry pak three phase 230V
1119737
CDP-1000
Corrosion dry pak three phase 460V
1119738
CDP-1000
Corrosion dry pak three phase 575V
1119740
CDP-2000
Corrosion dry pak three phase 208V
1119741
CDP-2000
Corrosion dry pak three phase 230V
1119742
CDP-2000
Corrosion dry pak three phase 460V
1119743
CDP-2000
Corrosion dry pak three phase 575V
Nitrogen Generators
Stock #
Model #
Description
1119400
NGP-250-1A
Nitrogen Generator 115V Single Phase
1119401
NGP-250-2A
Nitrogen Generator 208V Single Phase
1119402
NGP-250-3A
Nitrogen Generator 230V Single Phase
1119403
NGP-500-1A
Nitrogen Generator 115V Single Phase
1119404
NGP-500-2A
Nitrogen Generator 208V Single Phase
1119405
NGP-500-3A
Nitrogen Generator 230V Single Phase
29
Product List
1119432
NGP-1275M3-3A
Nitrogen Generator 230V Single Phase
1119433
NGP-1275M3-2B
Nitrogen Generator 208V Three Phase
1119434
1119435
1119438
NGP-1275M3-3B
Nitrogen Generator 230V Three Phase
NGP-1275M3-4B
Nitrogen Generator 460V Three Phase
NGP-1750M2-2B
Nitrogen Generator 208V Three Phase
1119439
NGP-1750M2-3B
Nitrogen Generator 230V Three Phase
1119440
NGP-1750M2-4B
Nitrogen Generator 460V Three Phase
1119443
NGP-1750M3-2B
Nitrogen Generator 208V Three Phase
1119444
NGP-1750M3-3B
Nitrogen Generator 230V Three Phase
NGP-1750M3-4B
Nitrogen Generator 460V Three Phase
1119448
NGP-1750M4-2B
Nitrogen Generator 208V Three Phase
1119449
NGP-1750M4-3B
Nitrogen Generator 230V Three Phase
1119450
NGP-1750M4-4B
Nitrogen Generator 460V Three Phase
1119453
NGP-2500M2-2B
Nitrogen Generator 208V Three Phase
1119445
1119454
NGP-2500M2-3B
Nitrogen Generator 230V Three Phase
1119455
NGP-2500M2-4B
Nitrogen Generator 460V Three Phase
1119458
NGP-2500M3-2B
Nitrogen Generator 208V Three Phase
1119459
NGP-2500M3-3B
Nitrogen Generator 230V Three Phase
NGP-2500M3-4B
Nitrogen Generator 460V Three Phase
1119463
NGP-2500M4-2B
Nitrogen Generator 208V Three Phase
1119464
NGP-2500M4-3B
Nitrogen Generator 230V Three Phase
1119465
NGP-2500M4-4B
Nitrogen Generator 460V Three Phase
1119468
NGP-2500M5-2B
Nitrogen Generator 208V Three Phase
1119469
NGP-2500M5-3B
Nitrogen Generator 230V Three Phase
1119470
NGP-2500M5-4B
Nitrogen Generator 460V Three Phase
1119460
Explosion Proof Devices
Stock #
Model #
Description
1010122
PIVSU-EX
Explosion proof post indicator valve switch
1010120
OSYSU-EX
Explosion proof OS & Y switch
1010121
OSYSU-EX-O
Outdoor Explosion proof OS & Y switch
1350102
PS10-EX
Explosion proof pressure switch 4-20 PSI
1350402
PS40-EX
Explosion proof pressure switch 10-175 PSI
1113202
VSRF-EX-2
Explosion proof vane type waterflow switch 2”
1113225
VSRF-EX-2 ½
Explosion proof vane type waterflow switch 2 ½”
1113203
VSRF-EX-3
Explosion proof vane type waterflow switch 3”
1113235
VSRF-EX-3 ½
Explosion proof vane type waterflow switch 3 ½”
1113204
VSRF-EX-4
Explosion proof vane type waterflow switch 4”
1113205
VSRF-EX-5
Explosion proof vane type waterflow switch 5”
1113206
VSRF-EX-6
Explosion proof vane type waterflow switch 6”
1113208
VSRF-EX-8
Explosion proof vane type waterflow switch 8”
1430501
FSEX-24PMR
Explosion proof strobe
1430500
FHEX-24SMR
Explosion proof horn
1430510
YL6
Explosion proof horn/strobe
1000400
RMS-6T-EXPWP
Explosion & weather proof pull station
Releasing Panel
Stock #
Model #
Description
3006142
PFC-4410RC
Water or agent extinguishing panel
3006461
PFC-6075R
75 Point Addressable Releasing Panel
3006462
RA-6075R
LCD Remote Releasing Annunciator
3001000
Abort Switch
Abort Switch
3001002
RCDS-1
Releasing Circuit Disable Switch
3004726
ARM-1
Auxiliary Relay Module
3004725
ARM-2
Auxiliary Relay Module
3006221
ARM-44
8 From C Relay Board f/PFC-4410RC
3006400
RA-4410RC
Remote Annunciator
5130080
BT6-4
Battery 6V, 4AH
5130092
BT-40
Battery 12V, 4AH
5130084
BT-80
Battery 12V, 8AH
5130090
BT-120
Battery 12V, 12AH
5130086
BT-180
Battery 12V, 18AH
5130097
BT-260
Battery 12V, 26AH
Notification Appliances
Stock #
Model #
Description
MH-12/24R
Remote mini horn 12/24V red
1119784
NGP-SPV
Nitrogen Generator Self-Purging Valve
4560041
1119799
NGP-SPV
Auto
Nitrogen Generator Automatic Self-Purging Valve
4560042
MH-12/24W
Remote mini horn 12/24V white
4560043
MH-12/24TR
Remote mini-horn terminal 12/24V red
30
Product List
4560044
MH-12/24TW
Remote mini-horn terminal 12/24V white
1750090
MBA-2410
Bell 10” 24VDC red
1610224
MH-120R
Remote mini-horn 120V red
1806024
PBA-246
Bell 6” 24VAC red
1610225
MH-120W
Remote mini-horn 120V white
1808024
PBA-248
Bell 8” 24VAC red
4550014
HP-25TR
Remote mini-horn terminal 12/24V red
1810024
PBA-2410
Bell 10” 24VAC red
4550015
HP-25TW
Remote mini-horn terminal 12/24V white
1806120
PBA-1206
Bell 6” 120VAC red
4890005
EH-24R
Horn Red
1808120
PBA-1208
Bell 8” 120VAC red
4890006
EH-24W
Horn White
1810120
PBA-12010
Bell 10” 120VAC red
4890007
EH-24PR
Horn Plain Red
4890250
AVSM-R
Sync module Red
4890008
EH-24PW
Horn Plain White
4890251
AVSM-W
Sync module White
4890010
S-24WR
Wall selectable strobe Red
4890011
S-24WW
Wall selectable strobe White
4890012
S-24PWR
Wall selectable strobe Plain Red
4890013
S-24PWW
Wall selectable stobe Plain White
Digital Communicators
Stock #
Model #
Description
PFC-6006
Sprinkler monitoring panel
4890030
HS-24WR
Wall selectable Horn/Strobe Red
3003011
4890031
HS-24WW
Wall selectable Horn/Strobe White
3006448
RA-6006
Remote Annunciator for PFC-6006 (Canada)
4890032
HS-24PWR
Wall selectable Horn/Strobe Plain Red
3006458
RA-6075
LCD annunciator
4890033
HS-24PWW
Wall selectable Horn/Strobe Plain White
4890020
CS-24R
Ceiling selectable strobe Red
4890021
CS-24W
Ceiling selectable strobe White
4890022
CS-24PR
Ceiling selectable strobe Plain Red
4890023
CS-24PW
Ceiling selectable strobe Plain White
4890040
CHS-24R
Ceiling selectable Horn/Strobe Red
4890041
CHS-24W
Ceiling selectable Horn/Strobe White
4890042
CHS-24PR
Ceiling selectable Horn/Strobe Plain Red
4890043
CHS-24PW
Ceiling selectable Horn/Strobe Plain White
4890054
SLP-24WRWP
Strobe Red low profile weather proof
SLP-24WWWP
Strobe White low profile weather proof
4890056
SLP-24PWRWP
Strobe Plain Red low profile weather proof
4890057
SLP-24PWWWP
Strobe Plain White low profile weather proof
4890064
HSLP-24WRWP
Horn/Strobe Red low profile weather proof
4890065
HSLP-24WW-
Horn/Strobe White low profile weather proof
4890055
Conventional Smoke & Heat Detectors
Stock #
Model #
Description
1430011
PS-24
Photoelectric smoke detector
1430006
BPS-2
Baseless smoke detector residential 2 wire eggshell
1430026
BPS-2W
Baseless smoke detector residential 2 wire white
1430007
BPS-4
Baseless smoke detector residential 4 wire eggshell
1430029
BPS-4W
Baseless smoke detector residential 4 wire white
1430012
PS-24H
Photoelectric smoke/heat detector
1000140
CR-135W
Heat detector 135° rate-of-rise
1000142
CF-135W
Heat detector 135° fixed temperature
1000141
CR-200W
Heat detector 200° fixed temperature/rate-of-rise
1000143
CF-200W
Heat detector 200° fixed temperature
1430009
DSD-P
Photoelectric duct detector
1000266
STS-2.5
Duct sampling tube 2 ½ ft.
1000468
STS-5.0
Duct sampling tube 5 ft.
1000263
STS-10
Duct sampling tube 10 ft.
WP
4890066
HSLP-24PWR-
Horn/Strobe Plain Red low profile weather proof
WP
4890067
HSLP-
Horn/Strobe Plain White low profile weather proof
24PWW-WP
1000755
SASH-24
Select-A-Strobe/Horn®/Sign 12/24V
1000760
SASH-120
Select-A-Strobe/Horn®/Sign 120V
1750070
MBA-126
Bell 6” 12VDC red
1750080
MBA-128
Bell 8” 12VDC red
1750060
MBA-1210
Bell 10” 12VDC red
1750100
MBA-246
Bell 6” 24VDC red
1750110
MBA-248
Bell 8” 24VDC red
Pull Stations
Stock #
Model #
Description
1000447
P32-1T
Pull station single action
1000476
P32-1T-LP
Pull station dual action
1000401
RMS-1T-WP
Pull station weather proof
31
Residential waterflow switch applications:
SASH-24/120V
PBA-AC SERIES
MBA-DC SERIES
SH-1224 SERIES
TO SPRINKLERS
RD13 Riser
Listed CPVC pipe
and fittings
1” to 2” sizes
TO DRAIN
VSR-SG
(VSR-ST USED WITH COPPER OR
STEEL SYSTEMS)
RBVS BALL VALVE SWITCHES
FOR INSTALLATION ON
BACKFLOW PREVENTER
32
DWG# 8900063-1
DRY PIPE VALVE SYSTEM
WATERFLOW ALARM INSTALLATION
Dry pipe valve system waterflow alarm installation:
RISER TO
SPRINKLER HEADS
PS10-1
PS40-2
SUPERVISORY
SWITCH
PS40-TM
BVL
WATERFLOW
PRESSURE
SWITCH
BLEEDER
VALVE
RTS
ROOM
TEMPERATURE
SWITCH
TO WATER
MOTOR GONG
INCLUDES PS40-2 PRESSURE SWITCH,
BVL BLEEDER VALVE, AND EASY TO READ,
HIGH QUALITY PRESSURE GUAGE
PRE-ASSEMBLED WITH GALVANIZED PIPE
WCS
WATER
COLUMN
SWITCH
RBVS
BALL VALVE SWITCH
AIR
PRESSURE
WATER LEVEL
CHECK
INTERMEDIATE
CHAMBER
BALL
DRIP
VALVE
PETCOCK
(OPEN)
WATER BY-PASS
TEST VALVE
(CLOSED)
DRAIN VALVE (CLOSED)
TAMPER
DEVICE
OSYSU
WATER
PRESSURE
GAUGE
OS & Y
CONTROL
VALVE
(OPEN)
RBVS
OSYSU-1,-2
BALL VALVE SWITCH FOR
INSTALLATION ON
BACKFLOW PREVENTER
SUPERVISORY SWITCH
NEMA 6P
UT
OPEN
TARGET
MOVES DOWN
AS VALVE IS
SHUT
PCVS-1
PTS-C
PLUG TYPE SUPERVISORY SWITCH
NEMA 6P
SUPERVISORY
SWITCH NEMA 6P
ON BUTTERFLY
VALVE
#8700021
PCVS-1
POST
INDICATOR
SUPERVISORY
SWITCH
NEMA 6P
33
WET
PIPE
SPRINKLER
SYSTEMS
Wet
pipe
sprinkler
systems:
ALARM CHECK VALVE
PS10-2
WFSR-F
RISER TO
SPRINKLER
HEADS
TO WATER
MOTOR GONG
OPTION 2
OPTION 1
WATERFLOW
PRESSURE
SWITCH
PRESSURE SWITCH
WITH RETARD
SHUTOFF
(OPEN)
WATER PRESSURE GAUGE
(SYSTEM PRESSURE)
(OPEN)
BY-PASS LINE
ALARM LINE
SHUTOFF
VALVE,
SUPERVISED
(OPEN)
PETCOCK
(OPEN)
PETCOCK
(OPEN)
CHECK VALVE
USE TO BUILD
SMALL EXCESS
SURGES
RETARD
CHAMBER
CHECK
WATER PRESSURE GAUGE
(CITY PRESSURE)
DRAIN
VALVE
(CLOSED)
(OPEN)
RBVS
OSYSU
SUPERVISORY
SWITCH
WATER BY-PASS
TEST VALVE
(CLOSED)
STRAINER
DRIP
CUP
OSY CONTROL VALVE
(OPEN)
CHECK
VALVE
“SHOTGUN” RISER
DRAIN
PIPE
WATER PRESSURE
FROM CITY MAINS
DWG. #8700023-2
BRANCH LINE
VSR-S
VSR
DRAIN
VALVE
(CLOSED)
SPRINKLER
BUTTERFLY
CONTROL VALVE
(OPEN)
DRAIN PIPE
PCVS-1
SUPERVISORY
SWITCH
34
#8700023
WATER PRESSURE
FROM CITY MAINS
PRE-ACTION DELUGE SYSTEM
SINGLE ZONE/ELECTRIC CROSS ZONE
Pre-action deluge system
Single zone/electric cross zone:
CLOSED SPRINKLER
PS10-2 OR PS40-2
LOW & HIGH AIR
CR/CF SERIES HEAT
DETECTOR OR LINEAR
HEAT DETECTION
PRESSURE
GAUGE
BVL
ZONE 2
ZONE 1
POTTER
SMOKE DETECTOR
SUPERVISORY ZONE
FROM AIR SUPPLY
PS10-1
WATERFLOW
ZONE 3
POTTER FIRE
ALARM BELL
OR POTTER
STROBE
RBVS
ZONE 4
MANUAL
PFC-4410RC
P32 SERIES
PULL STATION
RCDS-1
RELEASING CIRCUIT
DISABLE SWITCH
DELUGE
VALVE
24 VDC
SOLENOID
VALVE
OSYSU
OS&Y
GATE VALVE
35
At Potter Electric Signal Company, LLC,
QUALITY is the first order of business. Since 1898, we have served the
Fire Sprinkler industry on a world-wide basis. Today, we manufacture
a full line of Sprinkler Monitoring Devices and Corrosion Solutions with
unmatched quality and dependability.
We strive to provide you with the finest products and technical support
in the industry. You will also receive prompt service from a dedicated
team of professionals. After all, you, the customer, are the most
important member of that team.
So give us a call.
Potter Electric Signal Company, LLC
1609 Park 370 Place
St. Louis, MO 63042
P: 866-572-3005
F: 314-595-6999
www.pottersignal.com/sprinkler
8900063-S