GB.ELQZ455480.090815 Installation Instructions for the ELQZ-2-455-1-0/1 Push Button GOLD/COMPACT 1. General The push button kit consists of a non-locking push button and a surface-mounting frame. 2. Field of application The pushbutton is used for extended high speed or low speed operation outside ordinary in-operation periods preset in the air handling unit’s internal timer (switch clock). The pushbutton can also be used for controlling the air handling unit when the internal timer is not in use. 3. Operation The air handling unit is controlled to the appropriate operating mode via impulse from the pushbutton. The time delay can be set in the air handling unit’s control panel. Note that it is not possible to control the air handling unit via the pushbutton to the low speed mode while it is operating in the high speed mode. Push button with indicating lamp, ELQZ-2-455-1-1 4. Installation For recessed installation in equipment cubicles, dimension c-c is 60 mm. For surface mounting, use the surface-mounting frame supplied. 5. Technical data Enclosure Class: Colour: Materials: Indicating lamp Dimensions: Push button: Surface-mounting frame (WxHxD) IP 20 E white, NCS 1005Y20R Sheet steel, thermoplastic. Does not contain halogen ated PVC or lead. Red, 24V~ 82x82 mm 82x82x18 mm Specifications are subject to alteration without notice. Push button without indicating lamp, ELQZ-2-455-1-0 www.swegon.com 1 GB.ELQZ455480.090815 6. Electrical Wiring The electrical wiring should be carried out by a qualified electrician in accordance with local regulations. GOLD RX/PX/CX/SD Low speed High speed Terminals on controller card Terminals on controller card 46 47 48 49 1 2 1 2 1 2 1 2 L X L X X X ELQZ-2-455-1-0 ELQZ-2-455-1-0 Low speed with indicating lamp High speed with indicating lamp 59 58 11 12 46 47 59 2 3 4 1 1 1 2 H1 X 3 X ELQZ-2-455-1-1 Indicating lamp lit while the air handling unit’s fans operate at low speed. 2 www.swegon.com 13 14 2 1 4 H2 L 58 49 3 4 2 H1 X 48 3 4 H2 L X ELQZ-2-455-1-1 Indicating lamp lit while the air handling unit’s fans operate at high speed. Specifications are subject to alteration without notice. GB.ELQZ455480.090815 GOLD LP/COMPACT Low speed High speed Terminals on controller card Terminals on controller card 51) 61) 72) 82) 1 2 1 2 1 2 1 2 L X L X X X ELQZ-2-455-1-0 ELQZ-2-455-1-0 Low speed with indicating lamp High speed with indicating lamp 10 9 13) 23) 1 2 1 61) 10 3 4 1 2 H1 X 51) 3 34) 44) 2 1 4 H2 L 9 X ELQZ-2-455-1-1 Indicating LED is lit when the air handling unit is operating in the low speed mode. Select the external low speed function in the hand-held terminal; see the section on Inputs/Outputs in the Installation and Maintenance Instructions. 2) Select the external high speed function in the hand-held terminal; see the section on Inputs/Outputs in the Installation and Maintenance Instructions. 1) Specifications are subject to alteration without notice. 82) 3 4 2 H1 X 72) 3 4 H2 L X ELQZ-2-455-1-1 Indicating LED is lit when the air handling unit is operating in the high speed mode. Select the external low speed output function in the hand-held terminal; see the section on Inputs/Outputs in the Installation and Maintenance Instructions. 4) Select the external high speed output function in the hand-held terminal; see the section on Inputs/Outputs in the Installation and Maintenance Instructions. 3) www.swegon.com 3 GB.ELQZ455480.090815 4 www.swegon.com Specifications are subject to alteration without notice.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement