INSTALLATION INSTRUCTIONS
MODEL CE1625LSWR ELECTROMAGNETIC LOCK
DESCRIPTION
Door monitoring output
(reel sensor NO/NC)
Input Voltage
Current Draw
◎
12 to 24 VDC
12VDC - 680mA
24VDC - 340mA
1625LBS Holding Force
Dimensions( L x W x D )
Surface magnet
Strike plate
Material Armature housing
Strike plate
285 x 73 x 45 mm
210 x 70 x 17 mm
Stainless steel
Steel
1. First, loosely attach the settlement plate to the doorframe by inserting 2 screws through the 2 pre-drilled
holes of the settlement plate. Adjust the settlement plate to the desired position, the tighten
the settlement plate to the doorframe with another 10 screws.
2. Insert 2 included screws through the pre-drilled holes on the lock body and screw tightly with the settlement
plate.
3. Locate the proper position on the door that corresponds to the position of the electromagnetic lock when
closed. Insert 2 pins to the strike plate and drill 2 holes ( about 6~7mm ) on the door at the center of
the strike plate all the way through the entire door. Insert the M8 flate head screw through the center of
the strike plate, through the door, the washers, the aluminum tub and bolt. Do not install the stike
plate too tight. Leave some space to allow for best performance between the plate and lock.
Page 1 of 1