7040_pSeries_690_Installation_Guide

7040_pSeries_690_Installation_Guide

E

Rserver

IBM pSeries 690 Installation Guide

Installation Guide

SA38-0587-01

ERserver

IBM pSeries 690 Installation Guide

Installation Guide

SA38-0587-01

Second Edition April 2002

Before using this information and the product it supports, read the information in “Safety Notices” on page vii,

Appendix B, “Environmental Notices” on page 47, and Appendix C, “Notices” on page 49.

© Copyright International Business Machines Corporation, 2001, 2002. All rights reserved.

Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth is GSA ADP Schedule Contract with IBM Corp.

A reader’s comment form is provided at the back of this publication. If the form has been removed, address comments to Information Development, Department H6DS-905-6C006, 11400 Burnet Road, Austin, Texas 78758-3493. To send comments electronically, use this commercial internet address: [email protected]

. Any information that you supply may be used without incurring any obligation to you.

||

Contents

Safety Notices.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. vii

Electrical Safety .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. vii

Laser Safety Information .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. ix

Laser Compliance .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. ix

Data Integrity and Verification

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. xi

About This Book

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. xiii

ISO 9000 .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. xiii

Online Publications .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. xiii

Highlighting .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. xiii

Related Publications .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. xiii

Trademarks .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. xiv

Chapter 1. Getting Started .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 1

Documentation Overview .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 3

Configuring Online Documentation .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 5

Viewing the Online Documentation from the Documentation CD .

.

.

.

.

.

. 5

Installing the Online Documentation on a System .

.

.

.

.

.

.

.

.

.

.

. 5

Installing the online documentation on a Documentation Server .

.

.

.

.

.

. 5

Chapter 2. Installing the pSeries 690 .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 7

Minimum System Configuration .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 7

Multiple System Configurations .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 8

Prerequisites to Installing the pSeries 690 .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 8

Weight Reduction .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 8

Step 1. Unpack the pSeries 690 .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 8

Step 2. Check the Inventory .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 9

PrimaryRack Inventory.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 9

Secondary Rack Inventory (If Ordered) .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 9

Step 3. Position and Level the PrimaryRack .

.

.

.

.

.

.

.

.

.

.

.

.

. 10

Step 4. Attach and Cable Secondary Rack (If Ordered) .

.

.

.

.

.

.

.

.

. 11

Connecting Internal Power Cords for the Secondary Rack .

.

.

.

.

.

.

. 13

Connecting I/O Cables for the Secondary Rack .

.

.

.

.

.

.

.

.

.

.

. 14

Connecting the Integrated Battery Feature Power for the Secondary Rack .

.

. 15

Step 6. Observe this Safety Notice During Installation .

.

.

.

.

.

.

.

.

.

. 16

Step 7. Check the Cables and Connect I/O Devices .

.

.

.

.

.

.

.

.

.

. 17

Step 8. Verify that the Emergency Power Off (UEPO) Switch is in the

Off Position

17

Computer Room Emergency Power Off (EPO) .

.

.

.

.

.

.

.

.

.

.

. 17

Step 9. Check the Outlets and the Power Source .

.

.

.

.

.

.

.

.

.

.

. 19

Step 10. Connect and Route the Power Cords to the pSeries 690 .

.

.

.

.

.

. 21

Step 11. Install the Hardware Management Console (HMC) .

.

.

.

.

.

.

.

. 22

Position the HMC and Monitor.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 22

Connect the Cables .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 22

Connect the External Modem .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 26

Connect the LAN Cable (If Applicable) .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 27

Plug in the HMC Power Cord .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 27

iii

||

|

||

||

||

||

Step 12. Turn on the IBF Breaker (If Present) .

.

.

.

.

.

.

.

.

.

.

.

. 28

Step 13. Have the Customer Activate the Designated Circuit Breakers .

.

.

.

. 28

Step 14. Set the Console’s Date and Time .

.

.

.

.

.

.

.

.

.

.

.

.

. 28

Step 15. Ensure that the Latest Firmware, HMC Code and Adapter/Drive Microcode are Installed .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 29

Proceed to Verifying the Hardware Operation .

.

.

.

.

.

.

.

.

.

.

.

.

. 30

Chapter 3. Verifying the Hardware Operation .

.

.

.

.

.

.

.

.

.

.

.

. 31

Considerations Before Running This Procedure .

.

.

.

.

.

.

.

.

.

.

.

. 31

Loading the Online Diagnostics in Service Mode .

.

.

.

.

.

.

.

.

.

.

. 31

Loading the Standalone Diagnostics from CD-ROM.

.

.

.

.

.

.

.

.

.

.

. 32

Chapter 4. Completing the Installation .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 33

Install the Doors .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 33

Install the Front Door .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 33

Install the Rear Door .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 33

Configure the Network .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 35

Configure Inventory Scout Services .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 35

Collect Vital Product Data Information .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 36

Configure the Service Agent .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 37

Running System Verification .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 39

Performing Additional System Verification .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 40

Stopping the Diagnostics .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 40

Service Focal Point .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 40

Getting Started .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 41

Complete System Records and Installation Procedure .

.

.

.

.

.

.

.

.

.

. 42

Appendix A. Communications Statements .

.

.

.

.

.

.

.

.

.

.

.

.

. 43

Federal Communications Commission (FCC) Statement .

.

.

.

.

.

.

.

.

. 43

European Union (EU) Statement .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 43

International Electrotechnical Commission (IEC) Statement .

.

.

.

.

.

.

.

. 44

United Kingdom Telecommunications Safety Requirements .

.

.

.

.

.

.

.

. 44

Avis de conformité aux normes du ministère des Communications du Canada .

.

. 44

Canadian Department of Communications Compliance Statement .

.

.

.

.

.

. 44

VCCI Statement .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 44

Electromagnetic Interference (EMI) Statement - Taiwan .

.

.

.

.

.

.

.

.

. 45

Radio Protection for Germany .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 45

Appendix B. Environmental Notices .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 47

Product Recycling and Disposal .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 47

Environmental Design .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 47

Acoustical Noise Emissions .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 48

Declared Acoustical Noise Emissions .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 48

Appendix C. Notices

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 49

Appendix D. Securing the Rack

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 51

Positioning the Rack .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 51

Installing the Frame Kit .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 51

Rack Tie-Down Kits .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 51

iv

pSeries 690 Installation Guide

||

||

||

||

||

||

|

||

||

||

||

||

Mounting Internal Rack Components .

.

.

.

.

.

.

.

.

.

.

.

.

.

. 53

Determine Your Next Step .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 54

Attach the Rack to a Concrete (Non-Raised) Floor .

.

.

.

.

.

.

.

.

.

.

. 55

Attaching the Rack to a Short or Long Raised Floor .

.

.

.

.

.

.

.

.

.

. 59

Appendix E. Installing Multiple pSeries 690s To One Hardware Management

Console .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 65

Installing the 8-Port ASYNC Adapter.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 65

Connect the Serial Cables from the pSeries 690 to the 8-Port ASYNC Adapters 66

Installing the 128-Port ASYNC Adapter .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 67

128-Port ASYNC Adapter Line Connectors .

.

.

.

.

.

.

.

.

.

.

.

. 67

Setting a RAN Node Number .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 68

Configuring the 128-Port ASYNC Adapter .

.

.

.

.

.

.

.

.

.

.

.

.

. 69

Updating the Device Driver .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 71

Connect the Serial Cables from the pSeries 690 to the 128-Port ASYNC Adapters 71

Verify Installation is Complete by Using the HMC Interface .

.

.

.

.

.

.

.

. 72

Appendix F. System Records

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 75

Record the Identification Numbers .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 75

Record System - CPU, Memory, and I/O Configuration .

.

.

.

.

.

.

.

.

. 77

Verify that All Hardware is Present .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 81

Appendix G. Subsystem Positioning and Cabling .

.

.

.

.

.

.

.

.

.

. 83

Operator Panel Cable and Diskette Drive Cable to the Media Subsystem (rear view) 83

I/O Subsystem Positions, Fully Populated Primary and Secondary Rack

(rear view without IBF) .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 84

I/O Subsystem Positions, Fully Populated Primary and Secondary Rack (rear view with IBFs).

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 85

Placement of Subsystem 4 in a Two-Rack Configuration

(rear view with IBF) .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 86

I/O Subsystems (1 Through 4 Without IBFs) RIO Cabling to I/O Books .

.

.

.

. 87

I/O Subsystems (5 and 6) RIO Cabling to the Secondary I/O Book .

.

.

.

.

. 88

I/O Subsystems (7 and 8) RIO Cabling to the Third I/O Book .

.

.

.

.

.

.

. 89

I/O Subsystem (1 through 3 with IBFs) RIO Cabling to I/O Books .

.

.

.

.

.

. 90

RIO Cable to I/O Subsystem (4 through 6) with IBFs Installed .

.

.

.

.

.

.

. 91

I/O Subsystems (7 and 8) RIO Cabling to the Third I/O Book .

.

.

.

.

.

.

. 92

Power and SCSI Cables to the Media Subsystem .

.

.

.

.

.

.

.

.

.

.

. 93

Hardware Management Console for pSeries (HMC) to the Primary I/O Book .

.

. 94

Appendix H. Cabling Information .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 95

Power Cabling .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 95

RIO Cables and I/O Power Cables .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 97

Appendix I. Service Processor Setup and Test .

.

.

.

.

.

.

.

.

.

.

. 101

Service Processor Setup Checklist .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 101

Testing the Setup .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 102

Testing Call-In .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 102

Testing Call-Out .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 103

Serial Port Configuration .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 103

Contents

v

||

||

Appendix J. Removing and Installing the Rack Top Frame.

.

.

.

.

.

.

. 105

Options for Performing this Procedure.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 105

Required Tools .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 106

Removing the Covers .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 107

Side Cover Removal .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 108

Removing the Rack Top Frame for Clearance Through Doorways .

.

.

.

.

. 108

Preparing for Rack Top Frame Installation for pSeries 690 (Reduced Height

Option) RPQ8A1173 .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 115

Installing the Rack Top Frame .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 119

Cover Replacement .

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 126

Index

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. 127

vi

pSeries 690 Installation Guide

Safety Notices

Attention:

When moving or relocating certain configurations of the system, the Bulk

Power Regulators (BPR’s) must be removed from the top of the rack (front and rear) to ensure product stability. Specifically, removal of the top two BPR’s in the front and rear is required in systems that have less then 2 I/O drawers in the rack.

v v

A danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury.

Danger notices appear on the following pages:

vii

16

A caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury.

Caution notices appear on the following pages: v

viii

v

ix

v

16

v

19

v

19

v

22

For a translation of the safety notices contained in this book, see the

System Unit

Safety Information, order number SA23-2652.

Electrical Safety

Observe the following safety instructions any time you are connecting or disconnecting devices attached to the system.

DANGER

An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock.

Use one hand, when possible, to connect or disconnect signal cables to prevent a possible shock from touching two surfaces with different electrical potentials.

During an electrical storm, do not connect cables for display stations, printers, telephones, or station protectors for communications lines.

vii

CAUTION:

This product is equipped with a four-wire (three-phase and ground) power cable for the user’s safety. Use this power cable with a properly grounded electrical outlet to avoid electrical shock.

DANGER

To prevent electrical shock hazard, disconnect all power cables from the electrical outlet before relocating the system.

CAUTION:

This unit has more than one power supply cord. Follow procedures for removal of power from the system when directed.

CAUTION:

Energy hazard, remove power before servicing.

CAUTION:

Energy hazard, remove all jewelry before servicing.

viii

pSeries 690 Installation Guide

Laser Safety Information

CAUTION:

This product may contain a CD-ROM, DVD-ROM, or laser module on a PCI card, which are class 1 laser products.

Laser Compliance

All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR

Subchapter J for class 1 laser products. Outside the U.S., they are certified to be in compliance with the IEC 825 (first edition 1984) as a class 1 laser product. Consult the label on each part for laser certification numbers and approval information.

CAUTION:

All IBM laser modules are designed so that there is never any human access to laser radiation above a class 1 level during normal operation, user maintenance, or prescribed service conditions. Data processing environments can contain equipment transmitting on system links with laser modules that operate at greater than class 1 power levels. For this reason, never look into the end of an optical fiber cable or open receptacle. Only trained service personnel should perform the inspection or repair of optical fiber cable assemblies and receptacles.

Preface

ix

x

pSeries 690 Installation Guide

Data Integrity and Verification

IBM computer systems contain mechanisms designed to reduce the possibility of undetected data corruption or loss. This risk, however, cannot be eliminated. Users who experience unplanned outages, system failures, power fluctuations or outages, or component failures must verify the accuracy of operations performed and data saved or transmitted by the system at or near the time of the outage or failure. In addition, users must establish procedures to ensure that there is independent data verification before relying on such data in sensitive or critical operations. Users should periodically check the IBM support websites for updated information and fixes applicable to the system and related software.

xi

xii

pSeries 690 Installation Guide

About This Book

This book provides information on how to set up and cable the server, install and remove options, and verify server operation.

ISO 9000

ISO 9000 registered quality systems were used in the development and manufacturing of this product.

Online Publications

IBM

Eserver pSeries publications are available online. To access the online books, visit our Web site at: http://www.ibm.com/servers/eserver/pseries/library/hardware_docs/

Highlighting

The following highlighting conventions are used in this book:

Bold

Italics

Monospace

Identifies commands, subroutines, keywords, files, structures, directories, and other items whose names are predefined by the system. Also identifies graphical objects such as buttons, labels, and icons that the user selects.

Identifies parameters whose actual names or values are to be supplied by the user.

Identifies examples of specific data values, examples of text similar to what you might see displayed, examples of portions of program code similar to what you might write as a programmer, messages from the system, or information you should actually type.

Related Publications

v

The following publications provide related information:

The System Unit Safety Information, order number SA23-2652, contains translations of safety information used throughout this book.

v

The IBM Hardware Management Console for pSeries Operations Guide, order number SA38-0590, provides information to system administrators on how to install and use a Hardware Management Console (HMC) to manage a system.

v

The

Eserver pSeries 690 Service Guide, order number SA38-0589, contains reference information, maintenance analysis procedures (MAPs), error codes, removal and replacement procedures, and a parts catalog.

v v

The

Eserver pSeries 690 User’s Guide, order number SA38-0588, contains information on how to use the system, use diagnostics, use service aids, and verify system operations.

The RS/6000 and

Eserver

Diagnostic Information for Multiple Bus Systems, order number SA38-0509, contains diagnostic information, service request numbers

(SRNs), and failing function codes (FFCs).

xiii

v

The RS/6000 and

Eserver

Adapters, Devices and Cable Information for Multiple

Bus Systems, order number SA38-0516, contains information about adapters, devices, and cables for your server. This manual is intended to supplement the service information found in the Diagnostic Information for Multiple Bus Systems.

v v

The PCI Adapter Placement Reference, order number SA38-0538, contains information regarding slot restrictions for adapters that can be used in this system.

The Site and Hardware Planning Information, order number SA38-0508, contains information to help you plan your installation.

v

The Electronic Service Agent for pSeries and RS/6000 User’s Guide, order number

LCD4-1060, contains information on using the Electronic Service Agent.

Trademarks

The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both: v

AIX v v

AIX 5L

RS/6000 v v e (logo) pSeries

Other company, product, and service names may be trademarks or service marks of others.

xiv

pSeries 690 Installation Guide

Chapter 1. Getting Started

v

This chapter helps you get started with installing and configuring the pSeries 690 environment. The following information is included in the chapter: v

Eserver pSeries Roadmap v

Documentation Overview - Brief description of the printed and softcopy documentation shipped including targeted audience

Configuring Online Documentation - How to install and view the online documentation.

1

The

Eserver pSeries Roadmap helps you locate marketing, service, and customer task information. The roadmap guides you through the tasks and the publications that document those tasks.

2

pSeries 690 Installation Guide

Documentation Overview

This section provides descriptions, and target audience information for the

Eserver pSeries and AIX 5L documentation libraries. Some of the documentation may only be available in printed form or in softcopy form. Based on the documentation content, the books are divided into the following categories: Planning, Installing and Configuring, and Using the System.

Table 1. Planning

Documentation Title

Site and Hardware

Planning Information

Type

softcopy

Hardware Management

Console for pSeries

Operations Guide

Description

Contains information to help plan for site preparation tasks, such as floor-planning, electrical needs, air conditioning, and other site-planning considerations.

Audience

Marketing, system administrators

Provides information on how to configure and use a Hardware

Management Console (HMC). Logical partition (LPAR) tasks, such as configuring and managing partitions on multiple host servers, are included.

System administrators printed and softcopy

Table 2. Installing and Configuring

Documentation Title

Eserver pSeries 690

Installation Guide

Hardware Management

Console for pSeries

Operations Guide

AIX Installation in a

Partitioned Environment

Description

Provides information on how to install system hardware, cable the system, and verify operations.

Audience

Service personnel

Provides information on how to configure and use a Hardware

Management Console (HMC). Logical partition (LPAR) tasks, such as configuring and managing partitions on multiple host servers are included.

System administrators

Provides information on how to install

AIX in the operating system in an

LPAR environment.

System administrators

AIX 5L Installation Guide

Provides information on how to install, manage, and maintain the AIX 5L operating system.

AIX 5L Network

Installation Management

Guide and Reference

PCI Adapter Placement

Reference

AIX 5L Release Notes

Provides information about using

Network Installation Management

(NIM) to install the AIX 5L operating system.

Outlines system-specific PCI adapter slot placement and adapter support configurations.

Provides late-breaking information for a specific AIX release.

System administrators

System administrators

Service personnel

System administrators

Type

printed and softcopy printed and softcopy printed and softcopy printed and softcopy printed and softcopy printed printed and softcopy

Chapter 1. Getting Started

3

Table 2. Installing and Configuring (continued)

AIX 5L Documentation CD AIX documentation library (system management guides, user guides, application programmer guides, commands and files references, AIX man pages, and so on).

System administrators softcopy

Table 3. Using the System

Documentation Title

Hardware Management

Console for pSeries

Operations Guide

Eserver pSeries 690

User’s Guide

Description

Provides information on how to configure and use a Hardware

Management Console (HMC). Logical partition (LPAR) tasks, such as configuring and managing partitions on multiple host servers, are included.

Provides using, problem determination, and service processor information.

Audience

System administrators

System administrators

Eserver pSeries 690

Service Guide

Contains MAPs, removal and replacement, error code, and parts information to help diagnose and repair the system. Also contains MAPs that are not common to all systems.

Service personnel

Service personnel

Diagnostic Information for

Multiple Bus Systems

PCI Adapter Placement

Reference

Hardware Management

Console for pSeries

Maintenance Guide

Combines operating instructions for hardware diagnostic programs with common MAPs and SRNs (Service

Request Numbers).

Outlines system-specific PCI adapter slot placement and adapter support configurations.

Contains MAPs, removal and replacement, error code, and parts information to help diagnose and repair the system.

Provides information about adapters, devices, and cables that are attached to or used within the system.

Adapters, Devices, and

Cable Information for

Multiple Bus Systems

System Unit Safety

Information

Contains the English version of safety notices, as well as translations of those safety notices into other languages.

AIX 5L Documentation CD AIX documentation library (system management guides, user guides, application programmer guides, commands and files references, AIX man pages, and so on).

Service personnel

Service personnel

System administrators

System administrators, service personnel

System administrators

Type

printed and softcopy printed and softcopy printed and softcopy printed and softcopy printed printed and softcopy printed and softcopy printed and softcopy softcopy

4

pSeries 690 Installation Guide

Configuring Online Documentation

It is not necessary to install the operating system’s online documentation onto your server. You can access all of the documentation through the Internet at the following

Web address: http://www.ibm.com/servers/aix/library However, if you use the

Documentation Library Service to search any online documentation, it searches only the registered documentation that is installed. It does not search the documentation at the above Web site.

Viewing the Online Documentation from the Documentation CD

To view the online documentation, you must have an HTML browser installed on your system. The Netscape browser is located on the AIX 5L Expansion Pack.

Installing the Online Documentation on a System

To install the online documentation, do the the following:

1. Type smitty install_latest.

2. Enter INPUT device / directory for software in the field provided and press Enter.

3. In the Install Software menu, use the F4 key to list the documentation packages and filesets that are available to install. Select a package or fileset by highlighting the appropriate choice and pressing the F7 key. Press Enter when you have finished making your selections.

4. Select the appropriate responses for the remaining questions in the Install Software menu or accept the default choices. When you have finished making your selections, press Enter. From the confirmation menu, press Enter to install the software.

5. Press F10 to exit the SMIT menu and return to the command line.

Installing the online documentation on a Documentation Server

For detailed information on how to install and configure a documentation server and install the documentation, refer to the Using the Documentation Library Service section in the AIX 5L Installation Guide.

Chapter 1. Getting Started

5

6

pSeries 690 Installation Guide

Chapter 2. Installing the pSeries 690

Use the procedures in this chapter to set up your pSeries 690.

Minimum System Configuration

The minimum system configuration consists of the redundant bulk power subsystem, one processor subsystem, a media subsystem, and one I/O subsystem in the same rack, as well as access to a Hardware Management Console for pSeries (HMC).

2

3

8

9

4

5

6

7

1

1

2

3

4

Hardware Management Console

7040 Model 61RBulk Power

Subsystem

7040 Model 681 Processor

Subsystem

7040 Model 681 Media Subsystem

9

*

7

8

5*,6*

Primary 7040 Model 61R Integrated

Battery Feature (IBF) (Optional) for the

Primary Power Subsystem.

Redundant 7040 Model 61R Integrated

Battery Feature (IBF) (Optional) is placed in the rear.

7040 Model 61D I/O Subsystem

7040 Model 61D I/O Subsystem

(Optional)

7040 Model 61D I/O Subsystem

(Optional)

7040 Model 61D I/O Subsystem

(Optional, if features 5 and 6 are not installed).

7

A secondary rack may be required to support additional I/O subsystems and is placed to the left of the primary rack.

Multiple System Configurations

v v

The system configuration may vary. Other configurations include the following:

Multiple pSeries 690 servers attached to one HMC. For more information on this

configuration, see Appendix E, “Installing Multiple pSeries 690s To One Hardware

Management Console” on page 65.

Multiple HMCs attached to one pSeries 690.

Prerequisites to Installing the pSeries 690

v

Before installing the pSeries 690, ensure that the following have been completed: v

Doors have been ordered. The pSeries 690 has the following types of doors:

– PrimaryRack Front Door (Universal)

– Secondary Rack Front Door (Universal)

– Primary/SecondaryRack Rear Door (Slimline)

– Primary/SecondaryRack Rear Door (Acoustical)

Planning procedures outlined in Site and Hardware Planning Information, order number SA38-0508, are complete.

Weight Reduction

Certain system configurations may include a primary rack that weighs in excess of 2500 pounds (doors removed) as shipped from manufacturing. Some elevators have a weight restriction that prevents lifting these systems. To reduce the weight of affected systems to less than 2500 pounds, service personnel must remove all (up to six) plugged Bulk

Power Regulators (BPRs) installed in the system. For instruction on removing the

BPRs, see step 3 on page 110.

System affected by this weight limitation are the primary frame of systems having

7040-61R frame with 7040 Model 681 Processor Subsystem and three (or more) 7040

Model 61D I/O Subsystem and four (or more) IBFs. This weight reduction is only required for these systems when the installation requires the primary rack to be reduced temporarily to less than 2500 pounds during the installation process.

Note: Systems ordered with the height reduction feature do not require this weight reduction.

Step 1. Unpack the pSeries 690

Unpack the pSeries 690, and proceed to “Step 2. Check the Inventory” on page 9.

8

pSeries 690 Installation Guide

|

Step 2. Check the Inventory

Use the packing lists for each ship group to verify that you have all the items shipped with the pSeries 690.

Other tools that might be needed for installation, but not shipped with the system, include: v

Electronic Service Multimeter v

Lift Tool v

Service Vacuum v

Service Ladder v

Stepladder

Verify with the customer that the following items are available. You will need them to complete this installation.

v v

A floor plan, showing where to place each rack

The items necessary for installing a modem, including the correct telephone jack, line cords, cables, and a power source

Refer to the IBM Hardware Management Console for pSeries Operations Guide for information on the HMC inventory.

PrimaryRack Inventory

v

Front and rear door for the primaryrack v

Two line cords v

Optional display and keyboard. See “Position the HMC and Monitor” on page 22 for

further details.

Secondary Rack Inventory (If Ordered)

v

Front and rear door for the secondary rack v

Rack bolt-together kit hardware v

Optional display and keyboard, (refer to “Step 7. Check the Cables and Connect I/O

Devices” on page 17 for additional information).

Chapter 2. Installing the pSeries 690

9

Step 3. Position and Level the PrimaryRack

To adjust the leveling feet on the rack, do the following:

1. Ensure the rack is positioned according to the customer plan.

2. Loosen the jam nut on each leveling foot by turning the nut counterclockwise (away from the bottom of the rack).

3. Rotate each leveling foot downward until it contacts the surface on which the rack is placed.

4. Adjust the leveling feet downward as needed until the rack is level. When the rack is level, tighten the jam nuts against the base by turning the nut clockwise (toward the bottom of the rack).

1

2 3

1 Jam Nut

2 Leveling Foot

3

Rack Base (Front)

If the customer plans to secure the rack to the floor, see Appendix D, “Securing the

Rack” on page 51.

10

pSeries 690 Installation Guide

Step 4. Attach and Cable Secondary Rack (If Ordered)

Use the illustration on page 12 for more information on following these procedures.

1. Screw two standoffs to the primaryrack and the other two to the secondary rack.

2. Attach EMC bottom trim to the secondary rack, using four screws.

3. Place lower vertical trim foam on the secondary rack, starting at the EMC bottom trim.

4. Place top vertical foam on top of the bottom foam.

5. Place the top EMC trim on top of the secondary rack, using the middle two screws.

Do not tighten the screws yet.

6. Place the two vertical EMC trim panels into position. The trim panels are located so that the flanges point into the frame and fit on the tabs of the bottom and top EMC trim.

7. Screw down the top EMC trim to lock in the vertical trim.

8. Roll the two frames together being careful not to damage the EMC trim with the standoffs.

Chapter 2. Installing the pSeries 690

11

9. Use screws and washers to screw the frames together.

2

1

4

3

6

5

7

13

3

3

10

4

12

6

4

11

3

6

1 Secondary Rack

2 EMC Top Trim

3 Bolt and Washer (Qty. 4 each)

4 Threaded Standoff (Qty. 4 each)

5 Front Vertical Trim

6 J Bracket (Qty. 4 )

7 Primary Rack

11

12

13

8

9

10

6

Top Hat Side Cover

Primary Side Cover

Rear Vertical Trim

EMC Bottom Trim

Lower Vertical Foam

Top Vertical Foam

8

9

12

pSeries 690 Installation Guide

Connecting Internal Power Cords for the Secondary Rack

If you are installing a secondary rack, route the power cords from the primary rack to the secondary rack and connect them to the drawers in the secondary rack. See

Appendix H, “Cabling Information” on page 95 for additional information.

Secondary Rack Front Primary Rack Front

To Back

To Primary Rack

DCA1-Port 0 & 1

DCA2-Port 0 & 1

Chapter 2. Installing the pSeries 690

13

Connecting I/O Cables for the Secondary Rack

If you are installing a secondary rack, route the I/O cables from the primary rack to the secondary rack and connect them to the drawers in the secondary rack.

Primary Rack Rear

Secondary Rack Rear

To Primary Rack

Ports 0 and 1

Ports 0 and 1

Note: For more information on cabling the pSeries 690, see Appendix G, “Subsystem

Positioning and Cabling” on page 83.

14

pSeries 690 Installation Guide

Connecting the Integrated Battery Feature Power for the Secondary Rack

If you are installing an IBF for the secondary rack, route the cables as shown in the following illustration:

Secondary Rack Front Secondary Rack Rear

IBF-P1

IBF-P1

Chapter 2. Installing the pSeries 690

15

Step 6. Observe this Safety Notice During Installation

DANGER

An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock.

Use one hand, when possible, to connect or disconnect signal cables to prevent a possible shock from touching two surfaces with different electrical potentials.

During an electrical storm, do not connect cables for display stations, printers, telephones, or station protectors for communication lines.

CAUTION:

This product is equipped with a four-wire (three-phase and ground) power cables for the user’s safety. Use this power cable with a properly grounded electrical outlet to avoid electrical shock.

CAUTION:

This unit has more than one power supply cord. Follow procedures for removal of power from the system when directed.

CAUTION:

Energy hazard, remove all jewelry before servicing.

16

pSeries 690 Installation Guide

Step 7. Check the Cables and Connect I/O Devices

Cables may loosen during shipping. Check for loose cables before completing the

installation. For cabling illustrations, see Appendix G, “Subsystem Positioning and

Cabling” on page 83. For further details on the cable descriptions and labels, see

Appendix H, “Cabling Information” on page 95.

Connect any externally attached I/O devices to the I/O subsystems at this time using the procedures below.

If a display, Universal Serial Bus (USB) keyboard, and a USB mouse were ordered, do

the following. If these components were not ordered, proceed to 4 and 5 below.

1. Connect the keyboard cable to the Keyboard/Mouse Attachment Card PCI (adapter type N-D).

Note: Use any one of the four ports on the adapter; however, the adapter can support only one connection at a time.

2. Connect the mouse cable to the USB port on the upper corner of the rear of the keyboard.

3. Attach the display cable to either one of the two ports located on the graphics adapter .

4. Check all Blind Swap Cassettes for broken latches by lightly pushing down on rear of handles. Replace any broken latches.

5. Check to ensure adapters are seated by pushing down on the small metal tab on top of the adapter.

The placement of the graphics and keyboard adapters is described in the

PCI Adapter

Placement Reference, form number SA38-0538.

Step 8. Verify that the Emergency Power Off (UEPO) Switch is in the

Off Position

Note:

UEPO refers to the red Unit Emergency Power Off switch located on the unit.

EPO refers to the computer room Emergency Power off.

The unit emergency power off (UEPO) switch is located on the front of the primary frame (A Frame) of each pSeries 690. When the switch is tripped, utility power is confined to the machine power compartment. All volatile data will be lost.

|

|

|

|

|

|

|

|

Computer Room Emergency Power Off (EPO)

Attention:

When the integrated battery backup feature is installed and the room EPO is tripped, the batteries will engage and the computer will continue to run. It is possible to attach the computer room EPO system to the machine UEPO. When this is done, tripping the room EPO will disconnect all power from the line cords and the internal battery feature backup unit. In this event, all volatile data will be lost.

To incorporate the IBF into the room EPO a cable connection must be made to connect to the back of the system UEPO panel. The following diagrams illustrate how this

Chapter 2. Installing the pSeries 690

17

|

| connection is made.

|

|

|

|

|

|

This figure illustrates the back of the machine UEPO panel with the room EPO cable plugging into the machine. Notice the switch actuator. Once the switch actuator is moved to make the cable connection possible, the room EPO cable must be installed for the machine to power on.

4

3

2

1

AMP Part Number - 770019-1

Contact Number

2 Pole Normally Closed Pushbutton

|

|

|

|

In this figure, an AMP connector 770019-1 is needed to connect to the system UEPO panel. For room EPO cables using wire sizes #20 AWG to #24 AWG, use AMP pins part number 770010-4.

18

pSeries 690 Installation Guide

Step 9. Check the Outlets and the Power Source

CAUTION:

Do not touch the receptacle or the receptacle faceplate with anything other than your test probes before you have met the requirements in below.

Do the following to ensure that the customer has provided the correct power to the system:

__ 1. This system is equipped to use 200-240 V / 380-415 V / 480 V ac, three-phase.

Check that the correct power source is available.

__ 2. Have the customer locate and turn off the branch circuit breaker and attach tag

S229-0237, which reads “Do Not Operate.”

Note: All measurements are made with the receptacle faceplate in the normally installed position.

__ 3. Some receptacles are enclosed in metal housings. On receptacles of this type, perform the following steps: a. Check for less than 1 volt from the receptacle case to any grounded metal structure in the building, such as a raised-floor metal structure, water pipe, building steel, or similar structure.

b. Check for less than 1 volt from receptacle ground pin to a grounded point in the building.

Note: If the receptacle case or faceplate is painted, be sure the probe tip penetrates the paint and makes good electrical contact with the metal.

__ 4. Check the resistance from the ground pin of the receptacle to the receptacle case. Check resistance from the ground pin to building ground. The reading should be less than 1.0 ohm, which indicates the presence of a continuous grounding conductor.

Note: If measured impedance is greater that 1 ohm and the test instrument used was a digital multimeter, verify that the grounding impedance is correct by using an appropriately approved ground-impedance tester.

__ 5. If any of the checks made in substeps 2, 3 and 4 are not correct, ask the customer to remove the power from the branch circuit and make the wiring corrections; then check the receptacle again.

__ 6. Check for infinite resistance between the phase pins. This is a check for a wiring short.

CAUTION:

If the reading is other than infinity, do not proceed! Have the customer make necessary wiring corrections before continuing. Do not turn on the branch circuit CB until all the above steps are satisfactorily completed.

__ 7. Have the customer remove tag S229-0237, which reads “Do Not Operate” and turn on the branch circuit breaker.

Chapter 2. Installing the pSeries 690

19

Note: If your power source does not have a standard receptacle, check for voltage using local procedures.

Measure for appropriate voltages between phases. If no voltage is present on the receptacle case or grounded pin, the receptacle is safe to touch.

__ 8. With an appropriate meter, verify that the voltage at the outlet is correct.

Note:

v

For 200-240 V the acceptable phase-phase voltage measurement range is 180-254 V.

v v

For 380-415 V the acceptable phase-phase voltage measurement range is 342-440 V.

For 480 V the acceptable phase-phase voltage measurement range is

432-509 V.

__ 9. Verify that the grounding impedance is correct by using the ECOS 1020, 1023,

B7106, or an appropriately approved ground impedance tester.

__ 10. Have the customer turn off the branch circuit breaker and attach tag

S229-0237, which reads “Do Not Operate.”

20

pSeries 690 Installation Guide

| |

|| ||

|

|

| |

|| ||

|

|

| |

|

|| ||

|||||

|

|

|

||||

|

|

|

||||

|

||||

|

Step 10. Connect and Route the Power Cords to the pSeries 690

Before you connect the power cords, loosen or remove the cable retainers and filler plate located along the side and bottom of the frame.

The following tables shows a listing of each of the brackets and recommended range of cable sizes for each.

Part Number

07H6823

07H6824

11P1262

07H6764

07H6763

31L7174

Description

Cable Retention

Bracket

Cable Retention

Bracket

Cable Retention

Bracket

Filler Plate (thin)

Filler Plate (wide)

Soft Cable Ties (roll)

Quantity

2

12

4

3

4

1

Recommended Usage

Use in the base of the frame to retain cables leaving the frame. This bracket is used for large diameter cables.

Use in the base of the frame to retain the cables leaving the frame. This bracket is used for medium diameter cables.

Use in the base of frame to retain the cables leaving the frame. This bracket is used for small diameter cables and fiber.

Use in the base of the frame to cover the openings. Install in the base of the frame after all of the cable retention brackets are installed.

Use in the base of the frame to cover openings. Install in the base of the frame after all of the cable retention brackets are installed.

Use to organize the cables leaving frame.

The pSeries 690 has two power cords, one in the back and one in the front. To route the front power cord, do the following:

1. Connect the plug to the Bulk Power Assembly (BPA) and ensure that the dots are aligned on the plug and receptacle.

2. Secure the power cord in the channel with the brackets from top to bottom.

3. Loosen the screw on the brackets in the track on the left side. Remove the UEPO switch and route the power cord behind the UEPO switch.

4. Remove the lower panel of the frame, and route the cord through the channel under the frame.

5. Route the front power cord underneath the frame to the front floor tile hole. For more information on floor cutouts, refer to the Site and Hardware Planning

Information, order number SA38-0508.

To route the back power cord, do the following:

1. Connect the plug to the Bulk Power Assembly (BPA) and ensure that the dots are aligned on the plug and receptacle.

Chapter 2. Installing the pSeries 690

21

2. Secure the power cord from top to bottom in the channel with the brackets.

3. Remove the lower panel of the frame, and route the cord through the channel under the frame.

4. Route the rear line cord underneath the frame to the back floor tile hole. For more information on floor cutouts, refer to the Site and Hardware Planning Information, order number SA38-0508.

5. Replace the UEPO switch on the front side of the system.

Step 11. Install the Hardware Management Console (HMC)

The Hardware Management Console (HMC) user interface provides the functions needed to create and maintain a multiple-partitioned environment.

Position the HMC and Monitor

CAUTION:

Follow handling precautions provided with the unit.

v v v

Position the HMC and monitor at or near their desired location, using the following guidelines:

Use caution when lifting or moving the HMC.

Use caution when lifting or moving the monitor.

Leave enough space around the HMC to safely and easily complete the setup procedures.

v v

Be sure to maintain at least 51 mm (2 inches) of space on the sides of the system unit and 152 mm (6 inches) at the rear of the system unit to allow the system unit to cool properly. The front of the system requires a minimum of 76 mm (3 inches) of space. Blocking the air vents can cause overheating, which might result in a malfunction or permanent damage to the system unit.

Place the HMC in a location where all necessary power outlets and network connections can safely be reached.

v

Place the display in a stable and sturdy location.

Connect the Cables

Use the following steps to connect the cables to your HMC. Look for the small icons on the back of your HMC, which show where to attach the cables for the keyboard, mouse and monitor.

22

pSeries 690 Installation Guide

1. Attach the monitor cable to the monitor connector, and tighten the screws.

Chapter 2. Installing the pSeries 690

23

2. If a label for the monitor was shipped with your system, attach the label to the bottom-right corner of the monitor.

3. Attach the power cord to the monitor (item 1 in the following illustration). If the HMC has a voltage switch, ensure that it is in the correct position for the supply voltage.

Attention:

Do not the plug power cords into the electrical outlet at this point.

4. Connect the mouse and keyboard to their connectors, as shown in the following illustration.

24

pSeries 690 Installation Guide

5. Connect the HMC serial cable to serial port HMC1 on the primary I/O book. For two

HMCs, connect the redundant HMC into serial port HMC2 on the primary I/O book.

The following illustration shows the location of the serial ports on the back of the

HMC and the HMC connectors located on the primary I/O book.

1

2

3

Primary Rack

Primary I/O Book

4

5

Primary HMC Connected to serial port

HMC1* in Primary I/O Book

Optional Second HMC Connected to

Serial Port HMC2* in Primary I/O Book

* May be labeled HSC1 and HSC2 Power Plug to External Power Source

(wall plug)

The part numbers for the serial cables for the pSeries 690 to the HMC are as follows:

Part Number and Description

Part Number 11P3955 6m cable

Position

9 Position to 9 Position

Chapter 2. Installing the pSeries 690

25

Part Number 11P3956 15m cable

Part Number 31L7196 15m cable

9 Position to 9 Position

9 Position to 25Position

Connect the External Modem

The external modem is used in conjunction with the HMC’s Service Agent and Call

Home features. To properly service your machine, it is important that you configure the

Service Agent feature correctly the first time. For more information about configuring the

modem and the Service Agent feature, see “Configure the Service Agent” on page 37.

To connect the external HMC modem, do the following:

1. Connect the modem cable to the external HMC modem (1).

2. Connect the other end of the modem cable to serial port 2.

3. Connect the phone cable line port of the external modem (2).

4. Connect the other end of the phone cable to the analog jack on your wall.

|

|||

|||

|

|||

|||

|||

|||

|||

|||

|

|||

||||

|||

|

|

1

2

Modem Cable Outlet

Phone Cable Outlet

Check the Microswitch Setting on the Modem

Check the microswitch settings on the modem. The settings should be set as follows:

5

6

7

2

3

4

8

9

Switch

1

10

Position

Up

Up

Down

Down

*Down

Up

Up

Down

Down

Up

Function

Force Data Terminal Ready

(DTR)

Hardware Flow Control (&E4)

Result Codes Enabled

Modem Emulation Disabled

Auto Answer Enabled

Maximum Throughput Enabled

Ready to Send (RTS) Normal

Functions

Enable Command Mode

Remote Digital Loopback Test

Enabled

Dial-Up Line Enabled

26

pSeries 690 Installation Guide

|

|||

|

|||

|||

|

|||

|||

|

|||

|

11

12

13

14

Down

*Down

UP

Up

Asynchronous Terminal (AT)

Responses Enabled (Extended

Responses Enabled)

Asynchronous Operation

28.8KB Line Speed

15 Up Carrier Detect (CD) and Data

Set Ready (DSR) Normal

Functions

16 Up 2-Wire Leased Line Enabled

Note: * Only switches 5 and 12 are changed from the factory default settings.

Connect the LAN Cable (If Applicable)

The LAN cable is recommended because each active partition reports errors to the

HMC’s Service Focal Point application through the LAN network. The HMC must be attached to the system’s LAN, and each partition should have a LAN adapter assigned as a resource.

Connect the LAN to the adapters assigned to each partition and to the LAN connection on the HMC system hardware.

Plug in the HMC Power Cord

1. Plug in the power cord, as shown in the following illustration.

2. Plug in the power cords for the monitor, HMC, and modem into electrical outlets.

Chapter 2. Installing the pSeries 690

27

Step 12. Turn on the IBF Breaker (If Present)

Turn the Integrated Battery Feature (IBF) breaker on before turning the UEPO switch on the pSeries 690.

Step 13. Have the Customer Activate the Designated Circuit Breakers

Have the customer activate the designated circuit breakers by doing the following:

1. Ensure that the tag S229-0237, which reads “Do Not Operate,” has been removed.

2. Reset the circuit breaker.

Note: Only the following steps should be performed by the IBM service representative.

3. Turn the UEPO switch to the

ON position.

4.

Verify that the LEDs on the bulk power assembly are on. Verify that

OK displays on the pSeries 690 operator panel.

Step 14. Set the Console’s Date and Time

v v

The battery-operated clock keeps time and date for the HMC. You might need to set the console’s date and time under the following circumstances:

If the battery is replaced in the HMC

If your system is physically moved to a different time zone

To set the console date and time, do the following:

1. Power on the HMC.

2. Log in as hscroot (the password is abc123).

Note: User IDs and passwords are case-sensitive. Enter the user ID and password exactly as shown.

3. Click the HMC Maintenance Icon.

4. In the Navigation area, click the System Configuration icon.

28

pSeries 690 Installation Guide

5. Select Customize Console Date / Time to open the Customize Console Date /

Time window. This window is similar to the following:

6. Either type or use the up and down arrows to enter the date and time information as appropriate.

7. From the list, select the time zone closest to your location, and click OK.

To view the clock’s currently set time, click the Refresh button.

|

|

|

|

|

|

|

|

|

|

|

|

|

Step 15. Ensure that the Latest Firmware, HMC Code and Adapter/Drive

Microcode are Installed

Prior to completing the system installation, ensure the latest firmware, HMC code and adapter microcode are installed.

For the latest Firmware code: v

Access CORE

– From CORE, choose CORE Product Family and eServer pSeries - RS/6000

– Choose CORE Machine Type and pSeries - RS/6000 - Microcode-

System/Service

For HMC core: v

Go to the website http://techsupport.services.ibm.com/server/hmc?fetch=home.html

and select Corrective Service

For the latest adapter/drive microcode:

Chapter 2. Installing the pSeries 690

29

|

| v

Access CORE or go to the website http://techsupport.services.ibm.com/server/mdownload/download.html

Proceed to Verifying the Hardware Operation

The installation of the pSeries 690 is now complete. Proceed to Chapter 3, “Verifying the Hardware Operation” on page 31.

30

pSeries 690 Installation Guide

Chapter 3. Verifying the Hardware Operation

Use the system verification procedure discussed in this chapter to check the system for correct hardware operation.

Considerations Before Running This Procedure

v

Read the following before using this procedure:

The AIX operating system must be installed on your system before you attempt to perform this procedure.

v v

If this system unit is directly attached to another system unit or attached to a network, be sure communications with the other systems are stopped.

v

This procedure requires use of all of the system resources. No other activity can be running on the system while you are performing this procedure.

This procedure requires a Hardware Management Console for pSeries (HMC) attached to the HMC port on the pSeries 690.

v

This procedure runs the AIX online diagnostics in service mode on a system booted in Full System Partition mode.

Does the system have AIX diagnostics preinstalled?

YES

NO

Go to “Loading the Online Diagnostics in Service Mode”.

Go to “Loading the Standalone Diagnostics from CD-ROM” on page 32.

Loading the Online Diagnostics in Service Mode

To run the online diagnostics in service mode from the boot hard disk, do the following:

1. From the HMC, select Server

2. From the HMC, select Partition Management

Refer to the IBM Hardware Management Console for pSeries Operations Guide, order number SA38-0590, for more information on full system partitions.

3. From the HMC, select Server Management

4. Select the pSeries 690 in the Contents area, right-click on the mouse, and select

Open Terminal Window.

5. From the Service Processor menu on the VTERM, select Option 2 System Power

Control.

6. Select option 6. Verify that the state changes to currently disabled

. Disabling fast system boot automatically enables slow boot.

7. Select Option 98 to exit the system power control menu.

8. Use the HMC to power on the managed system in Full System Partition mode by selecting the managed system in the Contents area.

9. Highlight the desired system by right-clicking or selecting the desired system in the

Contents area. On the menu, choose Selected.

31

10. Select Power On.

11. Select the Power on Diagnostics Stored Boot List option.

12. Ensure that the media subsystem contains no media devices.

13. Enter any passwords, if requested.

Note: If you are unable to load the diagnostics to the point when the

DIAGNOSTIC

OPERATING INSTRUCTIONS

display, go to “Loading the Standalone Diagnostics from CD-ROM”.

Go to “Running System Verification” on page 39.

Loading the Standalone Diagnostics from CD-ROM

To run standalone diagnostics in service mode from CD-ROM, use the following steps:

1. Stop all programs, including the AIX operating system (get help if needed).

2. Remove all tapes, diskettes, and CD-ROMs.

3. Power off the pSeries 690 (refer to the IBM Hardware Management Console for pSeries Operations Guide, order number SA38-0590, for more information).

4. In your desktop area, right-click on the mouse and select Open Terminal Window.

5. From the service processor menu on the VTERM, select option 2, System Power

Control Menu.

6. Select option 6. Verify that the state changes to currently disabled

. Disabling fast system boot automatically enables slow boot.

7. Select option 98 to exit the system power control menu.

8. Use the HMC to power on the managed server in full system partition mode. Select

Power on Diagnostic Default Boot List.

9. Insert the CD-ROM into the CD-ROM drive in the media subsystem in the pSeries

690 ( not into the HMC CD-ROM drive).

Go to “Running System Verification” on page 39.

Note: If you are unable to load standalone diagnostics, call your support center for assistance.

32

pSeries 690 Installation Guide

Chapter 4. Completing the Installation

This chapter contains information on the final installation steps. Complete the steps described in this chapter after you verify the hardware operation as described in

Chapter 3, “Verifying the Hardware Operation” on page 31.

For instructions on returning the crates, refer to the crate unpacking instruction shipped with the pSeries 690.

Install the Doors

This section describes how to install the doors on the pSeries 690. For more

information on the doors, see “Prerequisites to Installing the pSeries 690” on page 8.

Install the Front Door

To install the front door, do the following (refer to illustration on page 34):

Note: After installing the front and rear doors, it may be necessary to adjust the latch.

1. Position the door so that both the top and the bottom hinge pins partially engage the hinges.

2. Simultaneously slide the top and bottom hinge pins (1) on the front door into the top and bottom hinges (2) on the rack.

3. Close the front door and engage the latch on the left side of the door.

Install the Rear Door

To install the rear door, do the following (refer to illustration on page 34):

1. Position the door so that both the top and the bottom hinge pins partially engage the hinges.

2. Simultaneously slide the top and bottom hinge pins (1) on the rear door into the top and bottom hinges (2) on the rack.

3. Close the rear door and engage the latch on the left side of the door.

33

1

2

4

1

2

1

2

1 Hinge Pin (Typical Front and Rear

Door)

2 Rack Hinge (Typical Front and

Rear Door)

3

4

3

2

1

Front Door

Rear Door

34

pSeries 690 Installation Guide

Configure the Network

To configure the network, do the following: v

Log in to the Hardware Management Console for pSeries (HMC) using the user ID hscroot and password abc123

.

Note: User IDs and passwords are case-sensitive. Enter the user ID and password exactly as shown.

v

Select the System Configuration Application in the Navigation area.

v

Select Customize Network Settings in the Contents area.

v v

Type the appropriate network information in the IP Address, Name Services, and

Routing tabs on the Network Configuration window.

Select OK.

For more information on configuring the network, refer to the IBM Hardware

Management Console for pSeries Operations Guide, order number SA38-0590.

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Configure Inventory Scout Services

Inventory Scout Services is an AIX tool that surveys managed systems for hardware and software information.

To set up Inventory Scout Services for each system managed by the HMC, and for each logical partition running an instance of AIX, all partitions must be configured in order to conduct microcode surveys or collect Vital Product Data (VPD).

To set up Inventory Scout Services for each managed system and partition, you must be a member of one of the following roles: v

System Administrator v

Advanced Operator v

Service Representative

Refer to the IBM Hardware Management Console for pSeries Operations Guide for more information on the previous roles.

Note:

v

The partition password requested in step 7 is actually the password for

Inventory Scout (invscout) User ID password on the AIX images.

v v

The Inventory Scout listening port is set by starting the invscoutd daemon on the AIX images. This port will default to 808.

If a system has been powered on using the Full System Partition power-on option, you must configure the Full System Partition to use Inventory Scout

Services.

To set up Inventory Scout Services for each managed system and partition, do the following:

Chapter 4. Completing the Installation

35

|

|

|

|

|

|

|

|

|

|

|

|

|

1. In the Navigation area, double-click the Inventory Scout Services icon.

2. In the Contents area, select Inventory Scout Profile Configuration.

3. From the list, select a managed system.

4. Select Next.

5. From the list, select the partition you want to configure.

6. Select Next.

7. The next window identifies the selected partition. Type the following: v

Partition password v

Inventory Scout listening port v

IP address of the AIX partition

Click Finish if you have completed configuration of all partitions.

OR

Click Back to continue to configure additional partitions until all are configured.

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Collect Vital Product Data Information

Use this task to collect the Vital Product Data (VPD) for the specified managed system into a file.

v v v

To collect the managed system’s VPD, you must be a member of one of the following roles:

System Administrator

Advanced Operator

Service Representative

To collect the managed systems VPD, do the following:

1. In the Navigation area, double-click the Inventory Scout Services icon.

2. In the Contents area, select Collect VPD Information.

3. From the list, select the name of the managed system for which you want to collect the Vital Product Data.

4. Select Next.

5. The wizard requests confirmation about the managed system, and then prompts you to insert a blank, DOS-formatted diskette into the HMC diskette drive.

6. Click Finish. This file is then copied to the diskette in the specified drive.

To conduct a microcode survey, please refer to the Hardware Management Console for pSeries Operations Guide.

36

pSeries 690 Installation Guide

|

Configure the Service Agent

Note: You must configure the network before you configure the Service Agent.

To start the Service Agent, click on the Service Agent icon on the HMC virtual terminal window.

If you are configuring Service Agent for the first time, select Start Service Agent

Processes to start the service agent processes. Select Service Agent UI. You are prompted to type specific information or parameters pertinent to Service Agent .

To configure the Service Agent, do the following:

1. Read and accept the License Agreement.

2. Type the word password for the initial password prompt. The word password is the default password supplied by IBM.

Note: User IDs and passwords are case-sensitive. Enter the user ID and password exactly as shown.

3. Type the information as follows:

Customer Contact Name

The person that IBM can reach when an error is reported to IBM by the

Service Agent.

Customer Phone Number

The phone number associated with the person whose name is placed in the Customer Contact Name field.

Customer Email

The e-mail address of the person whose name is placed in the Customer

Contact Name field.

Queue Country/Region

The country or region in which the HMC is located. Click the drop-down list to expand the country or region choices. Type the first letter of the desired country or region to move to the first occurrence of a country or region whose first letter matches your choice.

Gateway Type

The machine type of the processor subsystem.

Gateway Serial Number

The serial number of the processor substem that you designate to be the machine to send Service Agent information to IBM.

Gateway Model Number

The model number of the processor subsystem that you designate to be the machine to send Service Agent information to IBM.

4. Select Continue. The Service Agent interface displays.

Chapter 4. Completing the Installation

37

5. Select Network. Fill in the appropriate information.

Note: Some of the fields are prefilled with information taken from the Service

Agent initial configuration panel.

6. Select OK.

7. Expand the contents of the Gateway category by clicking the key next to your

Gateway machine.

8. Select Dialer.

9. Select Location. Select the location phone number closest to your physical location. Several of the fields are then completed by Service Agent based on the location phone number you selected.

10. Select Modem. Select the modem that you will use for Service Agent communications. After your selection, several of the remaining fields are filled in by

Service Agent.

11. Select OK to save the Dialer configuration.

12. Expand the contents of the Administration category by clicking the key to its left.

13. Select Register.

14. Select your Gateway machine by clicking it.

15. Select Register. The “Would you like to IGN now” window displays.

16. Select Yes. The Service Agent is now attempting to connect to the IBM Service

Agent server, using the modem you have selected.

17. Select CallLog. Check the details pane to view the status of the just-attempted call. To determine the success or failure of the connection attempt, examine the

Description column.

For more information on the Service Agent, refer to the

IBM Hardware Management

Console for pSeries Operations Guide, order number SA38-0590.

38

pSeries 690 Installation Guide

Running System Verification

Before you run system verification, the diagnostics must have been loaded. For

information about how to load diagnostics, see Chapter 3, “Verifying the Hardware

Operation” on page 31. While the power-on sequence is completing, the following

events occur: v

The power LED on the media subsystem operator panel starts blinking at a fast rate.

v

9xxx checkpoints appear in the operator panel display.

v

The power LED on the processor subsystem stops blinking and stays on.

v

If a secondary I/O subsystem is present, its power LED comes on and stays on.

1 2 3

!

1

2

3

6

5

R

4

Power on/off button

Power on/off LED

Operator panel display

4

5

6

Reset button

Service processor reset button

(Service use only)

Disturbance or system attention

LED

When the Diagnostic Operating Instructions display, do the following to run system verification:

1. Press Enter.

2. If the terminal type is requested, you must use the Initialize Terminal option on the

Function Selection menu to initialize the operating system before you can continue with the diagnostics.

3. Select the System Verification option on the Diagnostic Mode Selection menu.

4. To run a general checkout of all installed resources, select the All Resource option on the Diagnostic Selection menu. Follow the instructions on the screen to complete the checkout procedure.

To check one particular resource, select that resource on the Diagnostic Selection menu.

v

The checkout program ends with either of the following results:

The Testing Complete screen displays a message stating

No trouble was found

.

Chapter 4. Completing the Installation

39

v

The A Problem Was Detected On (Time Stamp) menu displays, with either a service request number (SRN) or an error code. Make a note of any codes displayed on the display or operator panel.

To perform additional system verification, go to “Performing Additional System

Verification”. To exit diagnostics, go to “Stopping the Diagnostics”.

Performing Additional System Verification

To perform additional system verification, do the following:

1. Press Enter to return to the Diagnostic Selection menu.

2. To check other resources, select the resource. When you have checked all of the

resources you need to check, go to “Stopping the Diagnostics”.

Stopping the Diagnostics

To stop the diagnostics, do the following:

1. To exit the diagnostics, press the F3 key (from a defined terminal) or press 99 (from an undefined terminal).

2. If you changed any attributes on your terminal to run the diagnostics, change the settings back to normal.

3. This completes the system verification.

If the server passed all the diagnostic tests, the verification process is complete and your server is ready to use.

If you received an error code, record the code and go to the pSeries 690 Service Guide.

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Service Focal Point

Service representatives must use the HMC as the starting point for all service issues.

The HMC groups various system management issues at one control point. From this control point, service representatives use the Service Focal Point application to determine an appropriate service strategy.

Traditional service strategies become more complicated in a partitioned environment.

Each partition runs on its own, unaware that other partitions exist on the same system.

If one partition reports an error for a shared resource such as a managed system power supply, other active partitions report the same error. Service focal point enables service representatives to avoid long lists of repetitive call-home information. Service Focal

Point recognizes that these errors repeat, and filters them into one error code for the service representative to review.

Errors that require service are reported to the HMC as serviceable events. Because the

HMC stores these serviceable events for 90 days and then discards them, it is important to have the partition and HMC date and time set correctly. For instance, if the

40

pSeries 690 Installation Guide

|

| date on a partition’s software is set 90 days behind the HMC’s set time, the serviceable events reported from this partition are immediately discarded.

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Getting Started

When you are setting up Service Focal Point, keep the following in mind: v

If the /var file system is full (either on the HMC or partitions), it can prevent

Serviceable Events from being reported to the HMC.

v v v

If the time configured on a partition is 90 days older than time configured on the

HMC, Serviceable Events cannot be reported.

Verify/configure the network - The network has to be configured prior to SFP working.

Verify that the HMC hostnames are fully qualified. For example, hostname should show hmc1.mydomain.mycompany.com.

v

Verify that the HMC and managed system are on the network and that DNS is working correctly. To do this, telnet to partitions from the HMC using the partitions’ hostname.

1. Verify or configure the network, by doing the following: v

Log in to the Hardware Management Console for pSeries (HMC) using the user

ID hscroot and password abc123

(if the password has been changed, obtain from Customer.)

Attention:

User IDs and passwords are case sensitive. Enter the user ID and password exactly as shown.

v v

Select the System Configuration Application in the Navigation area.

Verify the appropriate network information in the IP Address, Name Services, and Routing tabs on the Network Configuration window.

For Service Focal Point to be able to securely communicate with the partitions across the network, DNS or etc/hosts must consistently resolve the host names and

IP addresses of the HMC and the partitions to their canonical Fully Qualified

Domain Name (FQDN). Therefore, only fully qualified host names can be used in

Service Focal Point remote communication. Fully qualified host names cannot be more than 100 bytes in length.

2. Test Connectivity v

After insuring that the network is configured correctly, use the Test Connectivity function on the System Configuration Menu to test access to the network. The

Test Connectivity issues a ping command to the selected IP address. Obtain the

IP addresses of the Partition(s) from the customer and test the access.

3. Register Service Agent (if not already done) and generate a Test PMH - This must work correctly before continuing.

4. Test the AIX to SFP connection by doing the following:

Chapter 4. Completing the Installation

41

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

| v v

Note: Disable the Enable/Disable Call Home in SFP, as this will generate an event that will transfer to Service Agent and potentially create a PMH. Enable

Extended Error Data Collection.

Start concurrent diagnostics from the AIX partition.

Invoke either Problem Determination or System Verification.

v

Select only the Op Panel resource.

v v

Start the Op Panel test.

Answer

No

″ when asked whether the entry was correct or not (this will generate an SRN).

v v

Select

Yes

″ when prompted to send to Service Focal Point (this should create an event that can be viewed from Service Focal Point).

Run the same diagnostic multiple times to test the proper posting with timestamps and duplicate counts. The timestamps and duplicate counts should change.

There will only be posting of the event. Only Duplicate counts and timestamps will change. To generate more events, the open event must be changed to a closed status.

5. Test the AIX -> SFP-> SA path, by doing the following:

Note: This should never be attempted without first having the Remote Support actively engaged in the problem, as this results in a PMH being generated with an error that will be tracked as a real problem.

v

Insure that Call Home and Serviceable Events are enabled, the Service Agent delay has been changed to 1 minute in the Advanced Customization/Call

Controller field, then do steps a-h under the AIX to Service Focal Point connection verification instructions.

There is a default delay of 15 minutes from the time a Call Home Candidate request is received by Service Focal Point to Service Agent to dialout. You can changed this delay in Service Agent advanced customization, Call Controller pulldown.

If the event does not post, then contact software support.

For more information on the Service Focal Point, refer to the IBM Hardware

Management Console for pSeries Operations Guide, order number SA38-0590.

Complete System Records and Installation Procedure

Update the “System Records” in Appendix F, “System Records” on page 75 to reflect

the configuration of the system adapters and devices that are installed. After completing the records, deliver this book to the system administrator. The system administrator can proceed with installing and configuring the operating system.

42

pSeries 690 Installation Guide

Appendix A. Communications Statements

The following statement applies to this product. The statement for other products intended for use with this product appears in their accompanying documentation.

Federal Communications Commission (FCC) Statement

Note: This equipment has been tested and found to comply with the limits for a Class

A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Properly shielded and grounded cables and connectors must be used in order to meet

FCC emission limits. Neither the provider nor the manufacturer is responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.

Unauthorized changes or modifications could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

European Union (EU) Statement

This product is in conformity with the protection requirements of EU Council Directive

89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. The manufacturer cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of option cards supplied by third parties.

Consult with your dealer or sales representative for details on your specific hardware.

This product has been tested and found to comply with the limits for Class A

Information Technology Equipment according to CISPR 22 / European Standard EN

55022. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.

Attention:

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

43

International Electrotechnical Commission (IEC) Statement

This product has been designed and built to comply with IEC 60950.

United Kingdom Telecommunications Safety Requirements

This equipment is manufactured to the International Safety Standard EN60950 and as such is approved in the UK under the General Approval Number NS/G/1234/J/100003 for indirect connection to the public telecommunication network.

The network adapter interfaces housed within this equipment are approved separately, each one having its own independent approval number. These interface adapters, supplied by the manufacturer, do not use or contain excessive voltages. An excessive voltage is one which exceeds 70.7 V peak ac or 120 V dc. They interface with this equipment using Safe Extra Low Voltages only. In order to maintain the separate

(independent) approval of the manufacturer’s adapters, it is essential that other optional cards, not supplied by the manufacturer, do not use main voltages or any other excessive voltages. Seek advice from a competent engineer before installing other adapters not supplied by the manufacturer.

Avis de conformité aux normes du ministère des Communications du Canada

Cet appareil numérique de la classe A respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada.

Canadian Department of Communications Compliance Statement

This Class A digital apparatus meets the requirements of the Canadian

Interference–Causing Equipment Regulations.

VCCI Statement

The following is a summary of the VCCI Japanese statement in the box above.

This is a Class A product based on the standard of the Voluntary Control Council for

Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

44

pSeries 690 Installation Guide

Electromagnetic Interference (EMI) Statement - Taiwan

The following is a summary of the EMI Taiwan statement above.

Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures.

Radio Protection for Germany

Dieses Gerät ist berechtigt in Übereinstimmung mit Dem deutschen EMVG vom

9.Nov.92 das EG–Konformitätszeichen zu führen.

Der Aussteller der Konformitätserklärung ist die IBM Germany.

Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse A. Für diese von Geräten gilt folgende Bestimmung nach dem EMVG:

Geräte dürfen an Orten, für die sie nicht ausreichend entstört sind, nur mit besonderer

Genehmigung des Bundesministers für Post und Telekommunikation oder des

Bundesamtes für Post und Telekommunikation betrieben werden. Die Genehmigung wird erteilt, wenn keine elektromagnetischen Störungen zu erwarten sind.

(Auszug aus dem EMVG vom 9.Nov.92, Para.3, Abs.4)

Hinweis

Dieses Genehmigungsverfahren ist von der Deutschen Bundespost noch nicht veröffentlicht worden.

Appendix A. Communications Statements

45

46

pSeries 690 Installation Guide

Appendix B. Environmental Notices

Product Recycling and Disposal

This unit contains materials such as circuit boards, cables, electromagnetic compatibility gaskets and connectors which may contain lead and copper/beryllium alloys that require special handling and disposal at end of life. Before this unit is disposed of, these materials must be removed and recycled or discarded according to applicable regulations. IBM offers product return programs in several countries, for country specific instructions please refer to the following web site: http://www.ibm.com/ibm/environment/products/prp.phtml

This product may contain a sealed lead acid battery(s) or nickel-cadmium battery(s).

The battery(s) must be recycled or disposed of properly. Recycling facilities may not be available in your area. In the United States, IBM has established a collection process for reuse, recycling, or proper disposal of used sealed lead acid, nickel cadmium and nickel metal hydride batteries and battery packs from IBM equipment. For information on proper disposal of the batteries in this product, please contact IBM at

1-800-426-4333. For information on disposal of sealed lead acid or nickel cadmium batteries outside the United States, contact your local waste disposal or recycling facility.

Environmental Design

The environmental efforts that have gone into the design of this system signify IBM’s commitment to improve the quality of its products and processes. Some of these accomplishments include the elimination of the use of Class 1 ozone-depleting chemicals in the manufacturing process and reductions in manufacturing wastes. For more information, contact an IBM account representative.

47

Acoustical Noise Emissions

The equivalent continuous A-weighted sound pressure level at workstations (emission sound pressure level at the 1-meter bystander positions) does not exceed 70 dB(A).

Der Geräuschpegel der Einheit ist kleiner oder gleich 70 db(A).

Declared Acoustical Noise Emissions

Product Configuration

7040 Acoustical Doors

7040 Slimline Doors

Acoustical Characteristic

Declared A-Weighted Sound

Power Level, L

WAd

(B)

Operating Idle

7.5

7.5

7.9

7.9

Declared A-Weighted Sound

Pressure Level, LpAm (dB)

Operating

57

62

Idle

57

62

Notes:

1. Noise levels cited are for the typical configuration (A-Frame: Bulk Power, CEC cage, battery option, media drawer, and two I/O drawers).

2. The 0.6-B (6-dB) reduction in noise emission levels with the acoustical rear door corresponds to a factor of 4 reduction. That is, the noise level of a single A-Frame with Slimline covers is about the same as the noise level of four A-Frames with acoustical covers.

3. L

WAd is the upper-limit A-weighted sound power level; LpAm is the mean A-weighted sound pressure level at the 1-meter bystander positions; 1 B = 10 dB.

4. All measurements made in conformance with ISO 7779 and declared in conformance with

ISO 9296.

48

pSeries 690 Installation Guide

Appendix C. Notices

This information was developed for products and services offered in the U.S.A.

The manufacturer may not offer the products, services, or features discussed in this document in other countries. Consult the manufacturer’s representative for information on the products and services currently available in your area. Any reference to the manufacturer’s product, program, or service is not intended to state or imply that only that product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any intellectual property right of the manufacturer may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any product, program, or service.

The manufacturer may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to the manufacturer.

The following paragraph does not apply to the United Kingdom or any country

where such provisions are inconsistent with local law: THIS MANUAL IS

PROVIDED

AS IS

WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR

IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR

PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions; therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. The manufacturer may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Information concerning products made by other than the manufacturer was obtained from the suppliers of those products, their published announcements, or other publicly available sources. The manufacturer has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to products made by other than the manufacturer. Questions on the capabilities of products made by other than the manufacturer should be addressed to the suppliers of those products.

49

50

pSeries 690 Installation Guide

Appendix D. Securing the Rack

v

This appendix contains information about installing the rack for the pSeries 690. For further information, refer to PN44P0159, installation instructions for RPQ’s 8A1183,

8A1185, 8A1186 shown below:

RPQ 8A1183 for attaching the rack-mounting plates to the concrete floor (non-raised floor) v v

RPQ 8A1185 to attach the rack to a concrete floor when on a raised floor (9 1/2 inches to 11 3/4 inches high)

RPQ 8A1186 to attach the rack to a concrete floor when on a raised floor (11 3/4 inches to 16 inches high)

Positioning the Rack

Note: The customer should unpack the rack and position it in the room. If this has not been done, consult the customer and the marketing representative as necessary.

To unpack and position the rack, do the following:

1. Remove all packing and tape from the rack.

2. Position the rack according to the customer floor plan.

3. Lock each caster wheel by tightening the thumbscrew on the caster.

Thumbscrew

Installing the Frame Kit

The following tables show the parts required for each of the tie-down kits (a non-raised floor, short-raised floor, and a long-raised floor).

Rack Tie-Down Kits

11P4759 Frame tie-down Kit (Non-Raised Floor) (RPQ 8A1183)

Item

Item 3 in illustration on page

54.

Part Number

11P3527

Qty

2

Description

Shipping bar (lower)

Item 5 in illustration on page

54.

11P3529 4 Hinge plate

51

Item 8 in illustration on page

54.

Item 6 in illustration on page

54.

Item 2 in illustration on page

54.

Item 7 in illustration on page

54.

Item 1 in illustration on page

54.

Item 9 in illustration on page

54.

Item 10 in illustration on page

54.

Item 1 in illustration on page

56.

Item 2 in illustration on page

56.

Item 4 in illustration on page

56.

Item 5 in illustration on page

56.

Item 3 in illustration on page

56.

Item 6 in illustration on page

56.

11P3530

11P3531

11P3532

76X4687

1624804

1621546

1622307

11P3528

05N6345

05N6344

21L4309

0130985

05N6346

2

2

20

2

2

8

8

2

4

4

4

4

4

Latch plate

EQ support

Shipping bar (upper)

Latch bolt

Screw (hex flange, 20mm, long)

Screw (hex, 25mm, long, hinge)

Washer (M8, hinge)

Plate lock-down

Spacer

Bushing

Washer

Washer

Bolt

Item

Illustration on page 63.

Item 3 in illustration on

page 54.

11P4757 Frame tie-down Kit (Short - Raised Floor) (RPQ 8A1185)

Part Number Qty Description

Item 5 in illustration on

page 54.

44P0673

11P3527

11P3529

4

2

4

Turnbuckle Assembly (short)

Shipping bar (lower)

Hinge plate

11P3530 2 Latch plate Item 8 in illustration on

page 54.

Item 6 in illustration on

page 54.

Item 2 in illustration on

page 54.

Item 7 in illustration on

page 54.

Item 1 in illustration on

page 54.

11P3531

11P3532

76X4687

1624804

2

2

2

20

EQ support

Shipping bar (upper)

Latch bolt

Screw (hex flange, 20mm, long)

52

pSeries 690 Installation Guide

Item 9 in illustration on

page 54.

Item 10 in illustration on

page 54.

1621546

1622307

8

8

Screw (hex, 25mm, long, hinge)

Washer (M-8, hinge)

11P4758 Frame tie-down Kit (Long - Raised Floor) (RPQ 8A1186)

Item

Illustration on page 63.

Part Number

44P0674

Qty

4

Description

Turnbuckle Assembly (long)

11P3527 2 Shipping bar (lower) Item 3 in illustration on

page 54.

Item 5 in illustration on

page 54.

Item 8 in illustration on

page 54.

11P3529

11P3530

4

2

Hinge plate

Latch plate

2 EQ support Item 6 in illustration on

page 54.

Item 2 in illustration on

page 54.

11P3531

11P3532

Item 7 in illustration 54.

76X4687

1624804 Item 1 in illustration on

page 54.

Item 9 in illustration on

page 54.

Item 10 in illustration on

page 54.

1621546

1622307

2

2

20

8

8

Shipping bar (upper)

Latch bolt

Screw (hex flange, 20mm, long)

Screw (hex, 25mm, long, hinge)

Washer (M8, hinge)

Mounting Internal Rack Components

To mount the internal rack components, do the following:

Attention:

This procedure is performed by the service representative.

1. Using four M-8 (20 mm) screws (item 1 in illustration on page 54), install the top shipping bar (item 2 in illustration on page 54) at EIA unit location 32.

2. Using four M-8 screws (item 1 in illustration on page 54), install the bottom shipping bar (item 3 in illustration on page 54) at EIA unit location 18.

3. Repeat steps 1and 2 to install shipping bars in the rear of the rack.

4. Attach the front top hinge (item 5 in illustration on page 54) on the vertical rail

(located approximately at EIA unit 29-30 on the vertical rail) with two 25 mm

screws (item 9 in illustration on page 54) and two washers (item 10 in illustration on page 54).

5. Attach the front bottom hinge (item 5 in illustration on page 54) on the vertical rail

(located approximately on EIA unit 6-7 on the vertical rail) with two 25 mm screws

(item 9 in illustration on page 54) and two washers (item 10 in illustration on page

54).

Appendix D. Securing the Rack

53

6. Repeat steps 4 and 5 to install the hinges on the rear rail.

7. Attach the latch plate (item 8 in illustration on page 54) with two M-8 (20 mm) screws (item 1 in illustration on page 54).

8. Repeat step 7 to attach the latch plate in the rear of the rack.

9. Attach the triangular braces (item 6 in illustration on page 54) in both the front and

rear of the rack.

10. Install the latch bolts (item 7 in illustration on page 54).

5

9

10

2

6

6

5

9

10

1

8

1

2

3

5

9

10

8

7

3

1

5

9

10

Rack

Determine Your Next Step

Use the following to determine your next step: v v

If the rack is being attached to a concrete (non-raised) floor, proceed to “Attach the

Rack to a Concrete (Non-Raised) Floor” on page 55.

If the rack is being attached to a raised floor, proceed to “Attaching the Rack to a

Short or Long Raised Floor” on page 59.

v

If the rack is not being attached to the floor, proceed to “Step 3. Position and Level the PrimaryRack” on page 10.

54

pSeries 690 Installation Guide

Attach the Rack to a Concrete (Non-Raised) Floor

Use this procedure to attach the rack to a concrete (non-raised) floor.

Attention:

It is the customer’s responsibility to ensure the following steps are completed before the service representative performs the tie-down procedure.

Note: The customer should obtain the service of a qualified structural engineer to determine appropriate anchoring of the mounting plates. A minimum of three anchor bolts for each mounting plate must be used to secure the plates to the concrete floor. Because some of the drilled holes may be aligned with concrete reinforcement rods below the surface of the concrete floor, additional holes must be drilled. Each mounting plate must have at least three usable holes, two that are on opposite sides and opposite ends of each other, and one hole at the center. The mounting plates should be able to withstand 2500 pounds pulling force on each end.

Appendix D. Securing the Rack

55

1. Be sure the rack is in the correct location.

6

5

4

2

3

6

2

3

4

5

1

1

Rack Tie Down (Non-Raised Floor)

2. Place the mounting plates (item 1 in illustration on page 56), front and rear, in the

approximate mounting position under the system rack.

3. To align the mounting plates to the system rack, do the following:

a. Place the four rack-mounting bolts (item 6 in illustration on page 56) through

the plate assembly holes at the bottom of the rack. Install the bushings and

washers (item 4 and 5 in illustration on page 56) to ensure bolt positioning.

b. Position the mounting plates (item 1 in illustration on page 56) under the four rack-mounting bolts (item 6 in illustration on page 56) so that the mounting

bolts are centered directly over the tapped holes.

c. Turn the rack-mounting bolts (item 6 in illustration on page 56) three or four

rotations into the tapped holes.

56

pSeries 690 Installation Guide

4. Mark the floor around the edge of the mounting plates, as shown in the following illustration:

709.8 mm REF

(32x) 21 mm REF

27.5 mm REF

(10x) 65.5 mm REF

Caster

Rear

Mounting Plate

Caster

Caster

Front

Rack

Caster

Mounting Plate

(4x) ½ x 13 UNC REF

20.1 mm

750 mm REF

Mounting Plate

Bolt Locations

5. Remove the mounting bolts from the threaded holes.

6. Move the rack away from the mounting plates.

7. Mark the floor at the center of each hole in the mounting plate (including tapped holes).

8. Remove the mounting plates from the marked locations.

9. At the marked location of the tapped mounting holes, drill two holes approximately

1 inch to allow clearance for the ends of the two rack-mounting bolts. The ends of the rack-mounting bolts may protrude past the thickness of the mounting plate.

Drill one hole in each group of anchor bolt location marks as indicated on the marked floor.

10. Using at least three bolts for each mounting plate, mount the mounting plates to the concrete floor.

Attention:

It is the service representative’s responsibility to complete the following steps.

1. Reposition the system rack over the mounting plates.

Appendix D. Securing the Rack

57

2. Place the four rack-mounting bolts through the plate assemblies with the D-washer positioned so that the straight side of the washer is facing inward toward the system rack.

3. Place the isolator bushing (item 4 in illustration on page 56) inside the leveling foot

with a washer between the isolator bushing and the floor plate.

4. Turn the rack-mounting bolts three or four rotations into the tapped holes.

5. Turn the leveling foot of the plate assembly down until it contacts the mounting plate, and then level the rack using the four leveling feet.

6. Lock the leveling feet by tightening the lock nut.

7. Tighten the four rack-mounting bolts into the mounting plates.

58

pSeries 690 Installation Guide

Attaching the Rack to a Short or Long Raised Floor

Attention:

It is the customer’s responsibility to ensure the following steps are completed before the service representative performs the tie-down procedure.

Note: To accommodate a floor with a depth of more than 16 inches, asteel beam or a steel channel adapter for mounting the subfloor eyebolts are required. The customer must supply the floor eyebolts.

Consider the following when preparing the floor for tie-down: v

The hardware is designed to support a frame weighing no more than 2636 pounds.

v

The estimated maximum concentrated load on one caster for a 2636 pound-system is 900 pounds. For a multiple system installation, it is possible that one floor tile will bear a total concentrated load of 1800 pounds.

To install the eyebolts do the following:

1. Obtain the service of a qualified structural engineer to determine appropriate installation of the eyebolts.

2. Consider the following before installing the eyebolts: v

Floor eyebolts must be securely anchored to the concrete floor.

v

The minimum height of the center of the internal diameter is 1 inch above the concrete floor surface.

v v

The maximum is height 2.5 inches above the concrete floor surface. Higher than

2.5 inches can cause excessive lateral deflection to the tie-down hardware.

The eyebolt’s internal diameter should be 1 3/16 inch, and each eyebolt should be able to withstand 2700 pounds. The customer should obtain the service of a qualified consultant or structural engineer to determine the appropriate anchoring method for these eyebolts and to ensure that the raised floor can support the floor-loading specifications provided in the

Site and Hardware Planning

Information , form number SA38-0508.

Appendix D. Securing the Rack

59

3. Plan for installing four eyebolts positioned to match the dimensions given in the following illustrations.

24 in REF

610 mm REF (4x) 450 mm REF

64.6 mm

654.8 mm

(8) x 49.3 mm

Eyebolts

(8) 49.3 mm

Eyebolt

654.8 mm

64.6 mm

(4) Opening for Cables

2440 mm REF

96 in REF

24 Inch Floor Tile Layout

654.8 mm

64.6 mm

(4X) Opening for Cables

4. Install the eyebolts to the floor.

(4X) 450 mm REF

64.6 mm

654.8 mm

600 mm (23.6 Inch Floor) Tile Layout

600 mm REF

23.6 in REF

60

pSeries 690 Installation Guide

To install the frame, do the following:

Attention:

It is the service representative’s responsibility to complete the following steps.

1. Before starting the installation, check all cable openings in the floor panel and location of the rubber bushing holes so that they match the dimensions given in the following illustrations.

24 in REF

610 mm REF (4x) 450 mm REF

64.6 mm

654.8 mm

(8) x 49.3 mm

Eyebolts

654.8 mm

64.6 mm

(4) Opening for Cables

2440 mm REF

96 in REF

24 Inch Floor Tile Layout

Appendix D. Securing the Rack

61

(8) 49.3 mm

Eyebolt

654.8 mm

64.6 mm

(4X) Opening for Cables

(4X) 450 mm REF

64.6 mm

654.8 mm

600 mm (23.6 Inch Floor) Tile Layout

600 mm REF

23.6 in REF

2. Power off the system and make sure all cables and connectors are disconnected and are not dangling around the frame. The frame should be free to roll.

3. The floor eyebolts should be already secured to the concrete floor. Verify the height of the center of the floor eyebolt to the concrete floor or the steel beam/channel adapter mounted to the concrete floor. Ensure that the turnbuckles can accommodate the total height of the raised floor.

4. Remove the floor tiles around the area where the frame(s) will be installed.

62

pSeries 690 Installation Guide

5. Remove the pin and the spacer from the lower jaw (see the following illustrations).

1

10

11

9

3

4

8

6

2

7

5

12

13

3

4

1

2

5

6

7

Frame

Jam Nut

Rack Leveler

Rubber Bushing

Turnbuckle (Short or Long)

Lower Jaw

Pin

8

9

10

11

12

13

Floor Eyebolt (customer-supplied)

Threaded Rod

Nut

Washer

Spacer

Shaft

Note: The difference between the two turnbuckle assemblies is the length of the turnbuckle.

The Short Turnbuckle Assembly (part number 11P4755) is used for a 9 1/2 inches to 11 3/4 inches raised floor.

The Long Turnbuckle Assembly (part number 11P4756) is used for an 11

3/4 inches to 16 inches raised floor.

6. Place the spacer inside the floor eyebolt and place the floor eyebolt between the lower jaw. Reinstall the shaft, pin, and spacer.

7. Remove the threaded rod and rubber bushing from the turnbuckle assembly.

8. Install the floor tile that has the rubber bushing holes that are aligned with the eyebolt locations.

9. Install the rubber bushings in the floor tiles.

10. Move the frame so that the frame leveler is located over the rubber bushings.

Appendix D. Securing the Rack

63

Attention:

To avoid a tipping hazard, make sure that the frame casters do not roll into the cable opening.

11. Turn the leveling foot of the plate assembly down until it contacts the bushing, and then level the rack using the four leveling feet by tightening the lock nuts.

12. Lock the leveling feet by tightening the lock nut.

13. Insert the threaded rod into the inner hole of the leveler and the rubber bushing.

14. Thread down the threaded rod until the tip of the rod is approximately 1 inch inside the turnbuckle.

15. Insert the nuts and hand-tighten the nuts.

16. Repeat the previous three steps so that all assemblies are completely installed, as shown in the previous illustration.

17. Tighten all the nuts to 40 ft-pounds.

The frame is now secured.

64

pSeries 690 Installation Guide

|

|

|

Appendix E. Installing Multiple pSeries 690s To One Hardware

Management Console

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

| This appendix details how to install multiple pSeries 690 servers to one Hardware

Management Console (HMC). The HMC might have an 8-Port ASYNC adapter or a

128-Port ASYNC adapter installed to allow multiple servers to connect. Procedures for configuring either of the ASYNC adapters follows.

|

|

|

|

|

|

Installing the 8-Port ASYNC Adapter

The 8-port serial adapter is an option for the HMC. The 8-port serial adapter software is installed in the HMC’s base software image install. The 8-Port ASYNC Adapter must be configured by the service representative when the HMC is installed. You must log in as root user to do these procedures.

To configure the 8-port adapter in the system:

1. To allow access to the HMC Microcode Maintenance, obtain the password from software support and login as hscpe.

2. In the HMC Navigation area, click on Problem Determination.

3. In the Contents area, click on Microcode Maintenance. The User Authentication window opens.

4. Enter the HMC system unit’s serial number and the password provided by software support. The Microcode Maintenance Menu window opens.

5. Select Launch xterm shell to open a command prompt window.

6. Type su -, then login as root user with the root password.

7. Type the following command to run the configuration utility:

/usr/sbin/digiConf

.

The configuration utility will guide you through a series of questions: a. Question: How many boards would you like to install?

Answer: Enter the total number of 8 and/or 128 Port ASYNC adapters in the system.

b. Question: Board #1. What type of board is this? (’L’ for list)

Answer: Use board type 15 c. Question: Do you want to set Altpin on this board? (’y’ or ’n’)

Answer: No

If two 8-port adapters are installed in the system: a. Question: Board #2. What type of board is this? (’L’ for list)

Answer: Use board type 15 b. Question: Do you want to set Altpin on this board? (’y’ or ’n’)

Answer: No

The HMC is configured to load the adapter device driver upon reboot, reboot your

PC.

65

|

|

|

|

|

|

|

|

|

|

|

|

Connect the Serial Cables from the pSeries 690 to the 8-Port ASYNC Adapters

Up to two optional 8-port async adapters can be installed. The D-shell connector on the back of the adapter attaches to the 8-port expansion cable. The cable is about 3 feet long, and on the other end, has a slim box (8 1/2 inches x 3 inches x 1 1/2 inches) with

8 separate serial port connectors on it. The cable is labeled ISA 8-Port Cable. Serial cables can be connected from any of the ports on the 8-port expansion cable to the

HSC1 ports on the managed systems.

If you are using a second, redundant HMC, connect cables from all the pSeries 690

HMC1 ports to the 8-port cable on one HMC, and connect all the pSeries 690 HMC2 ports to the 8-port cable on the other HMC. The use of the second HMC system serial port is not recommended because this port is defaulted to be used for the modem, and requires a number of configuration steps to work with the pSeries 690.

66

pSeries 690 Installation Guide

|

|

|

|

|

||||

|||||

|

|

|

|

|

|

|

|

|

Installing the 128-Port ASYNC Adapter

The 128-Port ASYNC adapter is an option for the HMC. It must be configured by the customer engineer when the HMC is installed. The 128-Port ASYNC adapter software is installed in the HMC base software installation package.

This adapter provides the control function and connectors to attach eight 16-port remote async nodes (RANs). When all eight nodes are attached, this combination provides

128, EIA-232 or RS-422 communication ports.

|

|

|

|

|

|

128-Port ASYNC Adapter Line Connectors

The 128-Port ASYNC adapter has two 15 pin D-shell connectors on it. The connector that is closest to the edge connector that plugs into the HMC PC is line 1. The remote access nodes (RANs) are cabled in a daisy chain and are terminated using a line terminator. The following figure shows the adapter and the line connectors.

2

1

3-C

The following figure shows an example of a typical RAN configuration. RANs are connected to both line 1 and line 2 of the adapter in this example.

Adapter Line 2

Node

1

Node

2

4

1

Adapter Line 1

2

Node

1

Node

2

Node

3

3

1

2

RAN Nodes

RAN Nodes

3

4

RAN Node

Terminators

Appendix E. Installing Multiple pSeries 690s To One Hardware Management Console

67

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

| v v

Up to eight RANS may be attached to one adapter total. If 4 are attached to line one, then only 4 more can be attached to line 2.

RANs MUST be numbered in ascending order. The RAN closest to the adapter is assigned as node 1. No gaps in the numbering should occur. Example, numbering

RANs as 1, 3, 4 in a line will cause configuration problems.

|

|

|

|

|

|

|

|

|

|

Setting a RAN Node Number

The AIX Asynchronous Communications Guide, provides information on configuring and running diagnostics on the 128 Port ASYNC Adapter and associated RANs. To access the AIX Asynchronous Communications Guide, see the AIX Online documentation. The adapter identifies RANs by their node numbers. Each RAN in a daisy chain must have a unique node number (

1n-4n), which must be set during installation. The node numbers must be assigned in ascending order with the lowest number assigned to the

RAN closest to the 128-Port ASYNC adapter. The following figure shows the front panel of a RAN.

AC

To set the RAN node number, do the following:

1. Turn the RAN on and wait for the power-on self-test (POST) to complete.

2. When

P1 is displayed on the front panel seven-segment LED display, press the Left

Arrow button once. The current node number is displayed, for example,

1n for node

1.

3. Press the Right Arrow button to advance the node number through the eight possible settings ( 1n-8n).

4. When the desired node number is displayed, press the Left Arrow button again to select the number. The display should now read Pn (indicating a pass condition). If there was an error, the display reads

En.

In the case of duplicate node numbers, the RAN farthest from the host adapter displays

En

, instead of

AC

, when the system is started.

For additional information, see step 5 on page 25 for an illustration showing the location

of the HMC connectors located on the primary I/O book. In this case, instead of using the native serial ports on the back of the HMC as shown following illustration, use the

68

pSeries 690 Installation Guide

|

| ports on the 8-port expansion cable or a RAN if used.

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Configuring the 128-Port ASYNC Adapter

When a 128-Port ASYNC adapter is installed in the HMC and the HMC is first used, the adapter must be configured. To configure the 128-port ASYNC adapter in the HMC, two configuration utilities must be run (/usr/sbin/digiConf and /usr/sbin/cxconf). Log in as root user to run the utilities using the following procedures:

1. Obtain the root password from the customer.

2. To allow access to the HMC Microcode Maintenance as the hscpe user, contact software support and request the password.

3. In the HMC Navigation area, click on Problem Determination.

4. In the Contents area, click on Microcode Maintenance. The User Authentication window opens.

5. Enter the HMC system unit’s serial number and the password provided by software support. The Microcode Maintenance Menu window opens.

6. Select Launch xterm shell to open a command prompt window.

7. Type su -, then login as root user with the root password.

8. Type the following command to run the configuration utility:

/usr/sbin/digiConf

.

The configuration utility will guide you through a series of questions: a. Question: How many boards would you like to install?

Answer: Enter the total number of 8 and/or 128 Port ASYNC adapters are installed in the HMC PC.

b. Question: Board #1. What type of board is this? (’L’ for list)

Answer: Use board type 16 (IBM 128-Port ASYNC PCI) c. Question: How many ports does this digiBoard have?

Possible values:

1) 8

2) 16

3) 24

4) 32

5) 40

6) 48

7) 56

8) 64

9) 72

10) 80

Appendix E. Installing Multiple pSeries 690s To One Hardware Management Console

69

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

11) 88

12) 96

13) 104

14) 112

15) 120

16) 128

Board #1 How many ports? (1–16)

Answer: Count the total number of Enhanced RANs you are attaching to the

128-Port ASYNC adapter and multiply by two. For example: 2 (RANs) multiplied by 2 equals 4. Enter the selection number 4), for 32 in this example, at the prompt.

d. Question: Do you want to set Altpin on this board? (’y’ or ’n’)

Answer: No

If two 128-Port ASYNC adapters are installed in the system, the utility repeats the previous sequence of questions for each.

9. Type the following command to run the second configuration utility:

/usr/sbin/cxconf

. The configuration utility will guide you through a series of questions. The term C/CON is synonymous with Enhanced RAN or RAN: a. Question: How many C/X cards do you have?

Answer: Enter the total number of 128 Port ASYNC adapters installed in the

HMC PC.

b. Question: How many C/CONs (RANs) are connected to card 1 line 1?

Answer: Enter the total number of RANs on line 1. For this example, two concentrators (RANs) are connected to line 1.

c. Question: What type of wiring scheme are you going to use for card 1, line 1?

A) 8 Wire Direct

B) 4 Wire Direct

C) RS422 Sync

D) RS232 Sync

Answer: A d. Enter the type of communication mode to use on line 1.

(Type L for a list) [14]

Answer: 14 e. Question: How many ports does this C/CON (RAN) support? (conc #1)

Note: The maximum number of ports here is 16. [16]

Answer: 16 f. Question: How many C/CONs (RANs) are connected to card 1, line 2?

Answer: Enter the number of RANs connected to line 2. If RANs are connected

to Line 2, return to 9c above, and repeat the previous steps for line 2.

The HMC is configured to load the adapter device driver upon reboot. Reboot the HMC

PC.

70

pSeries 690 Installation Guide

|

|

|

|

|

|

|

|

|

|

|

|

|

Updating the Device Driver

To update the device driver for the 128-Port ASYNC adapter, perform the following:

1. Move the .rpm device package to the HMC.

2. At the command prompt, enter rpm -i -force epca-1.51-2.i386.rpm

The device driver is installed as /lib/modules/2.4.9–12/misc/epca.o

If lib/modules/2.4.9-12/kernel/drivers/char/epca.o exists, remove it.

3. Run the configuration utility, at the command prompt, enter /usr/sbin/digiConf.

4. Log in with the ID hscpe and open a command prompt window.

|

|

|

|

|

Connect the Serial Cables from the pSeries 690 to the 128-Port ASYNC Adapters

Up to two optional 128-port async adapters can be installed. The D-shell connectors on the back of the adapter attach to RANs. Serial cables can be connected from any of the ports on a RAN to the HMC1 ports on the managed systems.

If you are using a second, redundant HMC, connect cables from all the pSeries 690

HMC1 ports to the RAN on one HMC, and connect all the pSeries 690 HMC2 ports to the RANs on the other HMC. The use of the second HMC system serial port is not recommended because this port is defaulted to be used for the modem, and requires a number of configuration steps to work with the pSeries 690.

Appendix E. Installing Multiple pSeries 690s To One Hardware Management Console

71

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Verify Installation is Complete by Using the HMC Interface

The HMC provides a predefined user called hscroot. The hscroot password is abc123.

This hscroot user ID is a member of the System Administrator role. When the console is powered on for the first time, use this user ID to log in. After you are logged in, you can create additional users.

Note: If the customer is installing a second pSeries 690, the HMC may have been preinstalled, and the hscroot password has probably been changed. If the HMC was already present from a previous installation, ask the customer for a login ID.

The customer may have already set up a special login for a service representative; if so, use this login ID.

After you power on your HMC, the HMC login window displays, and prompts you to enter your user ID and password.

You might request that a special user ID be created for the Service Representative role to perform service functions.

After the installation is complete, thepSeries 690 displays on the HMC interface. It may take a few minutes for a new system to display in the user interface after the cable is connected. When you log in to the HMC, the HMC management window opens, and the management environment is already selected. Select Partition Management to see the list of managed systems.This window is divided into the Navigation area and the

Contents area. The management window looks similar to the following illustration:

|

|

|

|

|

The panel on the left (the Navigation area) displays a hierarchy of icons that represent collections of systems, individual systems, managed resources, and tasks. Each

Navigation area icon identifies an application. At the highest point, or root of the tree, is the Management Environment. The Management Environment contains one or more

72

pSeries 690 Installation Guide

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

| host system applications that are managed by the console. Each system application contains its own set of applications that contain managed objects, tasks, and actions for a related set of system entities or resources.

The panel on the right (the Contents Area) displays results based on the item you select in the Navigation area. When you click on an application in the Navigation area, the Contents area displays the tasks you can perform using that application.

v v v

Each HMC contains the following set of application icons:

System Manager Security

Partition Management

System Configuration v

Users v

Software Maintenance v

Inventory Scout Services v

Service Agent v

Service Focal Point v

Problem Determination

If the pSeries 690 is not displayed on the HMC interface, refer to the pSeries 690

Service Guide, for additional information.

Verify that the installation is complete for each pSeries 690 that you have connected to

the 8-port async adapter. When you are finished, go to Chapter 3, “Verifying the

Hardware Operation” on page 31.

Appendix E. Installing Multiple pSeries 690s To One Hardware Management Console

73

74

pSeries 690 Installation Guide

Appendix F. System Records

Use this appendix to keep a record of your server configuration.

Record the Identification Numbers

The basic server consists of the redundant bulk power subsystem, one processor subsystem, a media subsystem, and one I/O subsystem in the same rack, as well as access to one Hardware Management Console (HMC).

2

3

8

9

4

5

6

7

1

1

2

3

4

Hardware Management Console

7040 Model 61RBulk Power

Subsystem

7040 Model 681 Processor

Subsystem

7040 Model 681 Media Subsystem

9

*

7

8

5*,6*

Primary 7040 Model 61R Integrated

Battery Feature (IBF) (Optional) for the

Primary Power Subsystem.

Redundant 7040 Model 61R Integrated

Battery Feature (IBF) (Optional) is placed in the rear.

7040 Model 61D I/O Subsystem

7040 Model 61D I/O Subsystem

(Optional)

7040 Model 61D I/O Subsystem

(Optional)

7040 Model 61D I/O Subsystem

(Optional, if features 5 and 6 are not installed).

75

Use the following to keep a record of your components.

Component

pSeries 690

I/O Drawer 1

I/O Drawer 2

I/O Drawer 3

I/O Drawer 4 (or Drawer 7 if installed)

I/O Drawer 5

I/O Drawer 6

I/O Drawer 7

I/O Drawer 8

Serial Number

76

pSeries 690 Installation Guide

Record System - CPU, Memory, and I/O Configuration

The following illustration shows the location codes for the primary rack. These codes are used to identify the major functional units in the pSeries 690.

U1.35-P1-X1 Unused

U1.35-P1-X2

U1.35-P1-X3

U1.35-P1-X4

U1.35-P1-V1

U1.35-P1-V2

U1.35-P1-V3

U1.35-P2-X1 Unused

U1.35-P2-X2

U1.35-P2-X3

U1.35-P2-X4

U1.35-P2-V1

U1.35-P2-V2

U1.35-P2-V3

U1.18-F3 U1.18-

U1.18-X1

U1.18-F1

U1.18-X2

U1.18-F2

U1.17

U1.15-P1-V2 or U1.13

U1.13-P1-V1 or U1.13

U1.9

U1.5

U1.1

FRONT

U1.17

U1.15-P2-V4 or U1.13

U1.13-P2-V3 or U1.13

U1.9

U1.5

U1.1

REAR

Appendix F. System Records

77

The following illustration shows the location codes for the secondary rack. These codes are used to identify the major functional units in the pSeries 690 systems.

U2.19

U2.17-P1-V5

U2.13

U2.9

U2.5

U2.1

FRONT

78

pSeries 690 Installation Guide

U2.19

U2.17-P2-V6

U2.13

U2.9

U2.5

U2.1

REAR

Physical Memory

Card

Location available

MCM 0 installed U1.18-P1-C1

MCM 0 VPD Card U1.18-P1-H2.3

Memory U1.18-P1-M2

Memory U1.18-P1-M3

Other Description Information

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB

L3 Modules v

U1.18-P1-C6 v

U1.18-P1-C7 v

U1.18-P1-C10 v

U1.18-P1-C11

L3 VPD Card

MCM 2 installed

U1.18-P1-H2.1

U1.18-P1-C4

MCM 2 VPD Card U1.18-P1-H2.4

Memory U1.18-P1-M6

Memory U1.18-P1-M7

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB

L3 Modules v

U1.18-P1-C14 v

U1.18-P1-C15 v

U1.18-P1-C18 v

U1.18-P1-C19

U1.18-P1-H2.1

L3 VPD Card

MCM 1 installed U1.18-P1-C3

MCM 1 VPD Card U1.18-P1-H2.5

Appendix F. System Records

79

Physical Memory

Card

Memory

Location available

U1.18-P1-M4

Other Description Information

Memory U1.18-P1-M8

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB

L3 Modules

L3 VPD Card

MCM 3 installed v

U1.18-P1-C8 v

U1.18-P1-C12 v

U1.18-P1-C16 v

U1.18-P1-C20

U1.18-P1-H2.1

U1.18-P1-C2

MCM 3 VPD Card U1.18-P1-H2.6

Memory U1.18-P1-M1

Memory

L3 Modules

L3 VPD Card

Primary I/O Book

Secondary I/O

Book

U1.18-P1-M5

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB

Memory Book v

4 GB v

8 GB v

16 GB v

32 GB v

U1.18-P1-C5 v

U1.18-P1-C9 v

U1.18-P1-C13 v

U1.18-P1-C17

U1.18-P1-H2.1

v

U1.18-P1-H2 - Slot 0 -

I/O Drawer 1 v

- I/O Drawer 2 v

U1.18-P1-H3 - Slot 2 -

I/O Drawer 3 v

- I/O Drawer 4 v

RIO Connector A0 & A1 v

RIO Connector B0 & B1 v

Inside RIO Connector C0 and C1 v

Inside RIO Connector D0 and D1

80

pSeries 690 Installation Guide

Physical Memory

Card

Secondary I/O

Book

Secondary I/O

Book

Location available Other Description Information

v

U1.18-P1-H3 - I/O Slot 2

- Drawer 5 v

Drawer 6 v

Outside RIO Connector A0 and A1 v

Outside RIO Connector B0 and B1 v

U1.18-P1-H4 - I/O Slot 3

- Drawer 7 v

Drawer 8 v

Outside RIO Connector C0 and C1 v

Outside RIO Connector D0 and D1

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Verify that All Hardware is Present

v v v v

Verify that all hardware is present by doing the following:

Run lsslot -cpci to verify the adapters are plugged into the physical slot they are plugged in. Make note of the adapter types and positions the adapters are plugged in.

Run lsdev -Cc adapter to verify that all the adapters are in the available state. If any adapters are in defined state, contact your next level of support.

Run lspv and count the number of hdisks (hard disks) that appear in the system.

Verify that the number equals the number of hard disks physically in the system.

Make note of the hard disks and which one(s) contain rootvg.

Run lsdev -Cc disk to verify that all the hard disks are in the available state. If any of the hard disks are in the defined state, contact your next level of support.

v v

Run lsattr -El mem0 to verify the total amount of memory recognized by the system.

If the total is not the correct amount,contact your next level of support.

Run bindprocessor -q to verify how many processors are available. If the correct number or processors are not available, contact your next level of support.

Appendix F. System Records

81

82

pSeries 690 Installation Guide

Appendix G. Subsystem Positioning and Cabling

This section shows subsystem positioning and cabling for the pSeries 690.

Operator Panel Cable and Diskette Drive Cable to the Media Subsystem (rear view)

1

2

Primary I/O Book

Cable Connecting the Operator Panel to the Media Subsystem

3

4

Diskette Drive Data Cable

Media Subsystem

83

I/O Subsystem Positions, Fully Populated Primary and Secondary Rack

(rear view without IBF)

C1

C2

4

1

2

3

C1

C2

C3

C4

1

2

Primary Rack

Secondary Rack

Blank Space

Blank Space

First I/O Subsystem

Second I/O Subsystem

EIA 19

EIA 17

EIA 13

EIA 9

EIA 5

EIA 1

8

7

6

5

5

6

7

8

3

4

Third I/O Subsystem

Fourth I/O Subsystem

Fifth I/O Subsystem

Sixth I/O Subsystem

Seventh I/O Subsystem

Eighth I/O Subsystem

C4

C3

84

pSeries 690 Installation Guide

I/O Subsystem Positions, Fully Populated Primary and Secondary Rack (rear view with IBFs)

C1

C3

C2

2

3

1

4B

4B

8

2B

7

1

1

4

6

5

1

2

3

4

C1

C2

C3

1

Primary Rack

Primary I/O Book (Book 0)

Secondary Rack

First I/O Subsystem

Second I/O Subsystem

Third I/O Subsystem

Fourth I/O Subsystem

4B

5

6

7

2B

8

Four IBFs (primary rack), Position 4

Fifth I/O Subsystem

Sixth I/O Subsystem

Seventh I/O Subsystem

Two IBFs (secondary rack)

Eighth I/O Subsystem

Appendix G. Subsystem Positioning and Cabling

85

Placement of Subsystem 4 in a Two-Rack Configuration

(rear view with IBF)

C1

C2

2

3

1

4B

4B

4

EIA 9

EIA 5

EIA 1

C1

C2

Primary Rack

Secondary Rack

3

4

Third I/O Subsystem

Fourth I/O Subsystem

1

First I/O Subsystem

4B

Four IBFs

2

Second I/O Subsystem

Note: The physical location shown for I/O Subsystem 4 is populated only when IBFs are present and four or more I/O subsystems are installed.

86

pSeries 690 Installation Guide

I/O Subsystems (1 Through 4 Without IBFs) RIO Cabling to I/O Books

1

2

B0

B1

A1

A0

7

D0

D1

C1

C0

6

4

3

5

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

3

4

1

2

Primary Rack

Primary I/O Book

Third I/O Subsystem

Second I/O Subsystem

5

6

7

First I/O Subsystem

Fourth I/O Subsystem

Secondary I/O Book

Appendix G. Subsystem Positioning and Cabling

87

I/O Subsystems (5 and 6) RIO Cabling to the Secondary I/O Book

Shown Without IBFs

C1

C2

Primary Rack

Secondary Rack

5

6

Fifth I/O Subsystem

Sixth I/O Subsystem

C3

Secondary I/O Book

Note: RIO cabling to I/O Subsystems 5 and 6 is the same for configurations with or without the

IBFs.

88

pSeries 690 Installation Guide

I/O Subsystems (7 and 8) RIO Cabling to the Third I/O Book

Shown with IBFs

C1

C2

C0

C1

D0

D1

C3

2

3

1

4B

4B

8

7

0

4

0

6

5

C1

C2

C3

1

2

Primary Rack

Secondary Rack

Third I/O Book (Book 3)

First I/O Subsystem

Second I/O Subsystem

4

4B

5

6

7

Fourth I/O Subsystem

Two IBFs (maximum), Position 4

Fifth I/O Subsystem

Sixth I/O Subsystem

Seventh I/O Subsystem

3

Third I/O Subsystem

8

Eighth I/O Subsystem

Note: RIO cabling to I/O subsystems 7 and 8 is the same for configurations with or without the

IBFs.

Appendix G. Subsystem Positioning and Cabling

89

I/O Subsystem (1 through 3 with IBFs) RIO Cabling to I/O Books

1

B0

B1

A0

A1

6

2

C1

C0

4

3

5

1

2

3

4

5

6

Primary Rack

Primary I/O Book

Third I/O Subsystem

Second I/O Subsystem

First I/O Subsystem

Secondary I/O Book

90

pSeries 690 Installation Guide

1

0

1

0

1

0

1

0

1

0

1

0

A0

A1

B0

B1

C0

C1

Connection to I/O Book (Book 0)

Connection to I/O Book (Book 0)

Connection to I/O Book (Book 0)

Connection to I/O Book (Book 0)

Connection to I/O Book (Book 2)

Connection to I/O Book (Book 2)

RIO Cable to I/O Subsystem (4 through 6) with IBFs Installed

C1

C2

C3

A1

B0

B1

D1

D0

A0

2

3

1

4B

4B

8

7

4

6

5

C1

C2

C3

C4

1

2

3

4

4B

5

Secondary Rack

Primary Rack

Secondary I/O Book in I/O Slot 3

Secondary I/O Book in Slot 2

First I/O Subsystem

Second I/O Subsystem

Third I/O Subsystem

Fourth I/O Subsystem

Integrated Battery Feature (IBF)

Fifth I/O Subsystem

6

7

8

A0

A1

B0

B1

D0

D1

Sixth I/O Subsystem

Seventh I/O Subsystem

Eighth I/O Subsystem

Connection to I/O Book (Book 2)

Connection to I/O Book (Book 2)

Connection to I/O Book (Book 2)

Connection to I/O Book (Book 2)

Connection to I/O Book (Book 2)

Connection to I/O Book (Book 2)

Appendix G. Subsystem Positioning and Cabling

91

I/O Subsystems (7 and 8) RIO Cabling to the Third I/O Book

Shown with IBFs

C1

C2

C0

C1

D0

D1

C3

2

3

1

4B

4B

8

7

0

4

0

6

5

C1

C2

C3

1

2

3

4

4B

Primary Rack

Secondary Rack

Third I/O Book (Book 3)

First /O Subsystem

Second Subsystem

Third I/O Subsystem

Fourth I/O Subsystem

Two IBFs (maximum),

Position 4

92

pSeries 690 Installation Guide

5

6

7

8

C0

C1

D0

D1

Fifth I/O Subsystem

Sixth I/O Subsystem

Seventh I/O Subsystem

Eighth I/O Subsystem

Connection to I/O Book (Book 3)

Connection to I/O Book (Book 3)

Connection to I/O Book (Book 3)

Connection to I/O Book (Book 3)

Power and SCSI Cables to the Media Subsystem

2

1

4

5

3

6

7

3

4

1

2

Primary Rack

Primary I/O Book

Power Cable for Media Subsystem

Front Drives

Rear of Media Subsystem

5

6

7

SCSI Cable for Media Subsystem

Rear Drives

SCSI Cable for Media Subsystem

Front Drives

Power Cable for Media Subsystem

Rear Drives

Appendix G. Subsystem Positioning and Cabling

93

Hardware Management Console for pSeries (HMC) to the Primary I/O Book

To connect your HMC to the pSeries 690, connect the serial cable into serial port 1 located on the back of the HMC. Connect the other end of the serial cable into the

HMC1 connector located on the primary I/O book on the managed system. The following illustration shows the location of the serial ports on the back of the HMC and the HMC connectors located on the processor subsystem.

1

2

3

Primary Rack

Primary I/O Book

Power Plug to External Power Source

(wall plug)

4

5

94

pSeries 690 Installation Guide

Primary HMC Connected to HMC #1 in

Primary I/O Book (HMC #1 may be labeled HSC #1)

Optional Second HMC Connected to

HMC #2 in Primary I/O Book (HMC #2 may be labeled HSC #2)

Appendix H. Cabling Information

This appendix provides information on the location, and label colors of the pSeries 690 cables.

Power Cabling

1

3

2

4

Front

Rear

35

34

33

5

7

9

11

13

27

26

25

24

23

32

31

30

29

28

14

12

10

8

6

15

16

22

21

20

19

17

18

95

30

31

32

33

34

27

28

29

35

Index Part

Number

NA 1

2 NA

NA 3

4 NA

9

10

11

12

7

8

5

6

11P4449

11P4448

11P4451

11P4450

11P4453

11P4452

11P4455

11P4454

13

14

11P4457

11P4456

15 to 17 11P4303

16 to 18 11P4303

19,

20,

21,

22

NA

23

24

11P4462

11P4461

25

26

11P4460

11P4459

11P4463

11P4464

11P4465

11P4466

11P1596

11P1595

11P2998

11P4248

11P2998

1

1

1

1

1

1

1

1

1

1

1

1

Units Per

Assy

Description

1

1

Bulk Power Distribution on the A side of the system (BPD A

Side)

Bulk Power Distribution on the B side of the system (BPD B

Side)

A35-BPC-P03 to Bulk Power Fan P1-F1, Cable attached to

FAN (BPF-A)

B35-BPC-P03 to Bulk Power Fan P2-F1, Cable attached to

FAN (BPF-B)

B35-BPC-P08 to DCA-1-P01, Red

A35-BPC-P08 to DCA-1-P00, Red with white stripe

B35-BPC-P09 to DCA-2-P01, Red

A35-BPC-P09 to DCA-2-P00, Red with white stripe

B35-BPC-P10 to DCA-3-P01, Red

A35-BPC-P10 to DCA-3-P00, Red with white stripe

B35-BPD1-P08 to DCA-4-P01, Red

A35-BPD1-P08 to DCA-4-P00, Red with white stripe

B35-BPD1-P09 to DCA-5-P01, Red

A35-BPD1-P09 to DCA-5-P00, Red with white stripe

I/OB9-P00 to Media P02

I/OB9-P01 to Media P00

B35-BPDx-P0x to I/O Subsystem #x “RIO Cables and I/O

Power Cables” on page 97

1

1

1

1

1

1

1

1

2

1

1

2

2

B35-BPC-P05 to (AMD2-P01) MDA2-J02, Red

A35-BPC-P05 to (AMD2-P00) MDA2-J01, Red with white stripe

A35-BPC-P04 to (AMD1-P01) MDA1-J02, Red

A35-BPC-P04 to (AMD1-P00) MDA1-J01, Red with white stripe

A35-BPC-P06 to (AMD3-P00) MDA3-J01, Red with white stripe

B35-BPC-P06 to (AMD3-P01) MDA3-J02, Red

B35-BPC-P07 to (AMD4-P00) MDA4-J02, Red with white stripe

B35-BPC-P07 to (AMD4-P01) MDA4-J01, Red

B35-BPC-P02 to UEPO J01, Red

A35-BPC-P02 to UEPO J00, Red with white stripe

A35-BPR-P00 to A-IBF3-P00 (Secondary Frame)

B35-BPR-P00 to B-IBF3-P00 (Secondary Frame)

A35-BPR-P00 to A13-IBF2-P00

B35-BPR-P00 to B13-IBF2-P00

A35-BPR-P00 to A15-IBF1-P00

B35-BPR-P00 to B15-IBF1-P00

96

pSeries 690 Installation Guide

RIO Cables and I/O Power Cables

Index Number FRU Part

Number

11P2355

11P0272

44H9137

11P4490

11P4491

11P4492

11P4493

11P4494

11P4495

11P4496

11P4497

11P4498

11P4499

11P4500

11P4501

11P4502

11P4503

11P4504

11P4505

11P4514

11P4515

11P4516

11P4517

11P4506

11P4507

11P4508

11P4509

11P4510

11P4511

11P4512

11P4513

44P0190

44P0191

44P0192

44P0193

44P0194

1

1

1

1

1

Units Per

Assy

1

1

1

1

1

1

1

1

1

1

1

1

1

Up to 8

Up to 16

Up to 16

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Description

RIO cable 0.5-meter

RIO cable 2-meter

RIO cable 15-meter

I/O Subsystem 1 power cable (DCA1-P01)

I/O Subsystem 1 power cable (DCA1-P00)

I/O Subsystem 1 power cable (DCA2-P01)

I/O Subsystem 1 power cable (DCA2-P00)

I/O Subsystem 2 power cable (DCA1-P01)

I/O Subsystem 2 power cable (DCA1-P00)

I/O Subsystem 2 power cable (DCA2-P01)

I/O Subsystem 2 power cable (DCA2-P00)

I/O Subsystem 3 power cable (DCA1-P01)

I/O Subsystem 3 power cable (DCA1-P00)

I/O Subsystem 3 power cable (DCA2-P01)

I/O Subsystem 3 power cable (DCA2-P00)

I/O Subsystem 4 power cable, primary rack

(DCA1-P01)

I/O Subsystem 4 power cable, primary rack

(DCA1-P00)

I/O Subsystem 4 power cable, primary rack

(DCA2-P01)

I/O Subsystem 4 power cable, primary

(DCA2-P00)

I/O Subsystem 4 power cable, secondary rack

(DCA1-P01)

I/O Subsystem 4 power cable, secondary rack

(DCA1-P00)

I/O Subsystem 4 power cable, secondary rack

(DCA2-P01)

I/O Subsystem 4 power cable, secondary rack

(DCA2-P00)

I/O Subsystem 5 power cable (DCA1-P01)

I/O Subsystem 5 power cable (DCA1-P00)

I/O Subsystem 5 power cable (DCA2-P01)

I/O Subsystem 5 power cable (DCA2-P00)

I/O Subsystem 6 power cable (DCA1-P01)

I/O Subsystem 6 power cable (DCA1-P00)

I/O Subsystem 6 power cable (DCA2-P01)

I/O Subsystem 6 power cable (DCA2-P00)

I/O Subsystem 7 power cable (DCA1-P01)

I/O Subsystem 7 power cable (DCA1-P00)

I/O Subsystem 7 power cable (DCA2-P01)

I/O Subsystem 7 power cable (DCA2-P00)

I/O Subsystem 8 power cable (DCA1-P01)

Appendix H. Cabling Information

97

Index Number FRU Part

Number

44P0195

44P0196

44P0197

1

1

1

Units Per

Assy

Description

I/O Subsystem 8 power cable (DCA1-P00)

I/O Subsystem 8 power cable (DCA2-P01)

I/O Subsystem 8 power cable (DCA2-P00)

Note: The cables tied along the raceway may settle during shipment and might be tight when reconnecting to the BPA. The cable ties may need to be loosened and cable slack pulled back up in order to be reconnected.

From Description Label Color

A35B-BPD1A-P00

To

(A=Primary)

(Z=Secondary)

A09B-DCA1-P01 Purple W/Stripes

A35P-BPD1B-P00

A35B-BPD1A-P01

A35P-BPD1B-P01

A35B-BPD1A-P02

A35P-BPD1B-P02

A35B-BPD1A-P03

A35P-BPD1B-P03

A35B-BPD1A-P04

A35P-BPD1B-P04

A35B-BPD1A-P05

A35P-BPD1B-P05

A35B-BPD1A-P06

A35P-BPD1B-P06

A35B-BPD1A-P07

A35P-BPD1B-P07

A09B-DCA1-P00

A09B-DCA2-P01

A09B-DCA2-P00

A05B-DCA1-P01

A05B-DCA1-P00

A05B-DCA2-P01

A05B-DCA2-P00

A01B-DCA1-P01

A01B-DCA1-P00

A01B-DCA2-P01

A01B-DCA2-P00

A13B-DCA1-P01

A13B-DCA1-P00

A13B-DCA2-P01

A13B-DCA2-P00

BPD1A to I/O

Subsystem #1

BPD1B to I/O

Subsystem #1

BPD1A to I/O

Subsystem #1

BPD1B to I/O

Subsystem #1

BPD1A to I/O

Subsystem #2

BPD1B to I/O

Subsystem #2

BPD1A to I/O

Subsystem #2

BPD1B to I/O

Subsystem #2

BPD1A to I/O

Subsystem #3

BPD1B to I/O

Subsystem #3

BPD1A to I/O

Subsystem #3

BPD1B to I/O

Subsystem #3

BPD1A to I/O

Subsystem #4 (no IBF)

BPD1B to I/O

Subsystem #4 (no IBF)

BPD1A to I/O

Subsystem #4 (no IBF)

BPD1B to I/O

Subsystem #4 (no IBF)

Purple

Purple W/Stripes

Purple

Yellow W/Stripes

Yellow

Yellow W/Stripes

Yellow

Green W/Stripes

Green

Green W/Stripes

Green

Blue W/Stripes

Blue

Blue W/Stripes

Blue

98

pSeries 690 Installation Guide

From

A35B-BPD2A-P04

A35P-BPD2B-P04

A35B-BPD2A-P05

A35P-BPD2B-P05

A35B-BPD2A-P00

A35P-BPD2B-P00

A35B-BPD2A-P01

A35P-BPD2B-P01

A35B-BPD2A-P02

A35P-BPD2B-P02

A35B-BPD2A-P03

A35P-BPD2B-P03

A35B-BPD2A-P06

A35P-BPD2B-P06

A35B-BPD2A-P07

A35P-BPD2B-P07

A35B-BPD2A-P08

A35P-BPD2B-P08

A35B-BPD2A-P09

To

(A=Primary)

(Z=Secondary)

Z09B-DCA1-P01

Z09B-DCA1-P00

Z09B-DCA2-P01

Z09B-DCA2-P00

Z01B-DCA1-P01

Z01B-DCA1-P00

Z01B-DCA2-P01

Z01B-DCA2-P00

Z05B-DCA1-P01

Z05B-DCA1-P00

Z05B-DCA2-P01

Z05B-DCA2-P00

Z13B-DCA1-P01

Z13B-DCA1-P00

Z13B-DCA2-P01

Z13B-DCA2-P00

Z19B-DCA1-P01

Z19B-DCA1-P00

Z19B-DCA2-P01

Description Label Color

BPD1A to I/O

Subsystem #4 (with

IBF)

BPD1B to I/O

Subsystem #4 (with

IBF)

BPD1A to I/O

Subsystem #4 (with

IBF)

BPD1B to I/O

Subsystem #4 (with

IBF)

BPD2A to I/O

Subsystem #5

BPD2B to I/O

Subsystem #5

BPD2A to I/O

Subsystem #5

BPD2B to I/O

Subsystem #5

BPD2A to I/O

Subsystem #6

BPD2B to I/O

Subsystem #6

BPD2A to I/O

Subsystem #6

BPD2B to I/O

Subsystem #6

BPD2A to I/O

Subsystem #7

BPD2B to I/O

Subsystem #7

BPD2A to I/O

Subsystem #7

BPD2B to I/O

Subsystem #7

BPD2A to I/O

Subsystem #8

BPD2B to I/O

Subsystem #8

BPD2A to I/O

Subsystem #8

Yellow W/Stripes

Yellow

Yellow W/Stripes

Yellow

Red W/Stripes

Red

Red W/Stripes

Red

Purple W/Stripes

Purple

Purple W/Stripes

Purple

Green W/Stripes

Green

Green W/Stripes

Green

Blue W/Stripes

Blue

Blue W/Stripes

Appendix H. Cabling Information

99

From

A35P-BPD2B-P09

To

(A=Primary)

(Z=Secondary)

Z19B-DCA2-P00

Description

BPD2B to I/O

Subsystem #8

Label Color

Blue

100

pSeries 690 Installation Guide

Appendix I. Service Processor Setup and Test

Attention:

This procedure applies to modems attached to the serial ports (S1 and S2) on the primary I/O book (location U1.18-P1-H2). It does not affect the operation of the modem attached to the Hardware Management Console for pSeries (HMC).

The call-out function is normally handled by the Service Focal Point running on the

HMC.

For your convenience, an example of a basic service processor setup checklist is included here. Your setup may include more or fewer of the available features, so you can adjust this checklist for your own application.

Note: The call-out and surveillance options are disabled in partitioned systems.

Service Processor Setup Checklist

1. Shut down the managed system, and wait for the

OK in the physical operator panel.

2. Open a virtual terminal on the HMC.

3. Bring up the service processor menus.

4. Set the system name.

5. Enable Surveillance.

6. Configure call-in/call-out.

7. Attach modems if necessary. If modem attachment is not necessary, proceed to

step 8. To attach a modem do the following:

v

Exit the service processor menus.

v

Disable 350V dc outputs from the BPA by placing the UEPO switch in the off position.

v v

Attention:

Power is still present within the BPA with the UEPO off.

Place the UEPO switch in the on position.

Proceed to step 8.

8. Test both of the following: v

Call-In, page “Testing Call-In” on page 102

v

Call-Out, page “Testing Call-Out” on page 103

9. Use the “Save or Restore Hardware Management Policies,” in the “Introduction to

Tasks and Service Aids” section of the RS/6000 and

Eserver

Diagnostic

Information for Multiple Bus Systems to back up the service processor settings.

Note: This is strongly recommended to protect the usefulness of the service processor and the availability of the server.

Your service processor is now ready for use.

101

Testing the Setup

This section contains sample testing procedures to help ensure your setup is working.

These tests include communicating with the server operating system. Before you start, ensure that the necessary serial port(s) is configured. If you need assistance, refer to

“Serial Port Configuration” on page 103.

The server should be powered off as a result of the “Service Processor Setup

Checklist” on page 101.

Testing Call-In

1. At your remote terminal, call in to your server. Your server answers and offers you the service processor Main Menu after requesting your privileged-access password.

2. Select System Power Control.

3. Select Power-On System.

When you are asked if you wish to continue powering on the system, type Y.

4. After the system firmware and operating system have initialized the server, the login prompt displays at your remote terminal if you set up seamless modem transfer.

This may take several minutes. When the login prompt displays, you have successfully called the service processor.

5. Type logout to disconnect from the operating system. The message

No Carrier displays on your remote terminal.

6. Call your server again. The operating system answers and offers you the login prompt. If these tests are successful, call-in is working.

7. Log in and type shutdown -F to shut down your server.

8. The message

No Carrier displays on your remote terminal.

102

pSeries 690 Installation Guide

Testing Call-Out

During the setup, you entered your phone numbers for the pager and customer voice.

These numbers are used for this test.

1. Your remote terminal is disconnected as a result of the Call-In test.

2. Call your server again.

3. At the service processor Main Menu, select Call-In/Call-Out Setup menu, then select Call-Out test. This action causes a simulated error condition for the purposes of this test.

4. After a few moments, a message displays, regarding an illegal entry. Press Enter to clear the message and return to the main menu.

5. When your telephone rings, answer the call. You should hear the sound of a telephone being dialed. This is your computer trying to page you.

If this test is successful, call-out is working correctly.

Serial Port Configuration

To configure the serial port on an AIX system, run the following from an AIX console:

1. Log in as root user.

2. To determine if you have any serial ports already configured, type: lsdev -Cc tty

If no serial ports are configured, none are listed. If you want to configure serial ports that are not listed, continue with the remaining steps.

3. Identify the serial port(s) with the modem(s).

4. Type smit tty

5. Select add tty

6. Select RS232

7. Select Baud rate 9600 or higher.

8. Select login enable and set the flow control to RTS.

9. Commit the selections and set up any other needed serial ports.

10. Exit SMIT.

Appendix I. Service Processor Setup and Test

103

104

pSeries 690 Installation Guide

Appendix J. Removing and Installing the Rack Top Frame

|

|

|

Options for Performing this Procedure

Two scenarios exist for performing this procedure: v

Removing and installing the rack top frame for clearance through doorways v

Installing the rack top frame that was shipped unattached from the rest of the frame.

Note: If the clearance is close (an interference of 1/2 inch or less), the removal of the

side covers may be all that is required. For side cover removal, please see “Side

Cover Removal” on page 108.

For additional information, refer to RPQ8A1173. For clearance procedures, go to

“Removing the Rack Top Frame for Clearance Through Doorways” on page 108. For

the reduced height procedure, go to “Preparing for Rack Top Frame Installation for pSeries 690 (Reduced Height Option) RPQ8A1173” on page 115.

Note: Due to the weight of the rack top frame, two people are required to restore the rack to full height.

The weight of components is outlined in the following table:

Item

Rack Top Frame and Crate

Rack Top Frame with Power (4 BPRs and 4 BPDs)*

BPR

BPD

BPE

Rack Top Frame without Rails

Rack Top Frame with Rails

Notes:

1. Maximum total weight can be up to 561 lbs.

2. * Can be shipped with up to six BPRs and six BPDs.

463 lbs.

329 lbs.

30 lbs.

14 lbs.

40 lbs.

66 lbs.

73 lbs.

Weight

105

Required Tools

The following tools are necessary to remove and/or install the rack top frame: v v

Ladder

Step Ladder

Table 4. Hand Tools

Tool

Ratchet

Ratchet Accessories

Drive Socket

Drive Ratchet

Drive Socket

Torque Tool (PN6422789)

Description

3/8 inches Square Drive

3/8 inches Drive, 6 inches Extension X2 (8 inch reach required)

3/8 inches (10mm)

1/4 inches

5/16 inches (8mm)

Included in the tool kit and used for various fru’s, such as the BPR, BPC, BPDs, and BPFs.

106

pSeries 690 Installation Guide

| |

|| ||

|

||||

| |

|| ||

|

|||||

|

|

|

|

|

Removing the Covers

This procedures describes how to remove and replace the side covers of the pSeries

690

1

4

2

5

3

6

7

15

11

9

14

3

4

1

2

12

13

Rear Cover PN44P0127

Rear Cover PN44P0107

PN11P4106 Hinge PN2665525

Screw

PN44P0126 Rear Latch

PN54G2882 Screw

11

12

9

10

10

PN11P3535 Hinge PN2665525

Screw

PN11P1096 Front Latch

PN54G2882 Screw

PN77G0599 Screw PN1625437

Washer, Side Cover

PN05N6585 J Bracket PN2665528

Screw, Side Cover

Appendix J. Removing and Installing the Rack Top Frame

107

| |

|| ||

| |

|| ||

|

||||

|

5

6

7

PN44P0126 Right Cover

PN54G2882 Screw

PN11P3600 Left Cover PN44P0125

Screw

PN44P0105 Front Cover

13

14

15

PN05N6585 J Bracket PN

2665528 Screw

PN44P0126 Right Cover PN

54G2882 Screw

PN44P0125 Left Cover PN

54G2882 Screw

|

|

|

|

|

|

|

|

|

|

|

|

|

|

Side Cover Removal

1. Always remove the right side cover first.

2. Remove the (2) Screws and washers inside the frame (P/N’s 77G0599 and

1625437).

3. Remove the (3) Screws at the top of the frame (P/N’s 54G2882). The use of a step ladder is recommended for this procedure.

4. With all the screws removed, rock the cover to the right from the top. There are features built into the cover that lock it behind the left hand cover - these need to clear before you can lift the cover from the frame. Tilting the top of the cover away from the frame after the feature tabs have cleared the left hand cover makes lifting the cover easier.

5. Follow steps 2 and 3 for removing the left hand cover.

6. With all the screws removed from the cover, tilt the top of the cover away from the frame and lift off.

Removing the Rack Top Frame for Clearance Through Doorways

1. Use the jack screws to stabilize and lift the rack off the floor.

a. Loosen the jam nut on each leveling foot by turning the nut counter-clockwise.

b. Rotate each leveling foot downward until it contacts the surface on which the rack is placed.

c. Adjust the leveling feet downward as needed until the rack is level. When the rack is level, tighten the jam nuts against the base by turning the nut clockwise.

108

pSeries 690 Installation Guide

1

2 3

1 Jam Nut

2 Leveling Foot

3

Rack Base

Appendix J. Removing and Installing the Rack Top Frame

109

2. Disconnect cables from the BPDs.

3. Remove the front and rear BPRs, BPDs, BPCs, and the fan assemblies.

Attention:

Make note of location identification of the BPRs and BPEs for later reinstallation. The pSeries 690 will not power on if these components are not reinstalled in their original location.

1

2

3

4

5

6

1 BPE

2 BPD

3 BPC

4

5

6

BPR

BPF

Fan Cover Plate a. Remove the BPRs (item 4 in previous illustration) as follows:

__ Step 1) Make sure the ON/OFF switch is in the UNLOCK/OFF position.

__ Step 2) Loosen the thumbscrew on each side of the BPR using the torque tool (PN6422789).

__ Step 3) Rotate the release levers up on each side of the BPR. This will unseat the BPR.

__ Step 4) Pull the BPR straight out from the Bulk Power Enclosure (BPE).

__ Step 5) Repeat for the other BPRs. There can be up to six BPRs, with three in front and three in back.

b. Remove the Bulk Power Controllers (BPCs) (item 3 in previous illustration) as follows:

__ Step 1) Loosen the thumbscrew on each side of the BPC using the torque tool (PN6422789).

__ Step 2) Pull the BPC straight out from the Bulk Power Enclosure.

__ Step 3) Repeat for the other BPC. There are two BPCs, with one in front and one in back.

c. Remove the BPDs (Item 2 in the previous illustration), as follows:

__ Step 1) Loosen the thumbscrew on each side of the BPD using the torque tool (PN6422789).

__ Step 2) Pull the BPD straight out from the Bulk Power Enclosure (BPE).

__ Step 3) Repeat for the other BPDs. There can be up to four BPDs, with two in front and two in back.

d. Remove the BPFs (Item 5 in the illustration on page 110) as follows:

Note: A grille covers the fan on the front the fan assembly.

1) Locate the BPF to be replaced.

2) Remove the fan cover plate (Item 6 in the illustration on page 110).

3) Loosen the upper and lower fasteners using the torque tool (PN6422789).

110

pSeries 690 Installation Guide

4) Pull the BPF straight out of the BPE.

5) Repeat for the other BPF. There are two BPFs, one in front and one in back.

e. Remove any front and rear bulk power fillers.

4. Remove the top frame side covers (items 7 and 8 in illustration on 112) as follows:

__ Step a. Remove the two screws at the top of each side panel.

__ Step b. Lift up the panel from the top, and pull it away from the rack.

5. Remove the frame extenders as follows: a. Remove the UEPO switch (item 6 in the following illustration).

v

Unplug the cables.

v

Remove the top and bottom screws.

b. Remove the rear top and bottom frame extender (item 1 and 4 in the following illustration) by removing the two screws (one on each side).

c. Remove both rear frame extenders (items 2 and 3 in the following illustration) by removing the three bolts on each side.

d. Repeat steps 5b and 5c for the front frame extenders.

Appendix J. Removing and Installing the Rack Top Frame

111

8

3

2

1

4

7

1 Top Extender

2 Left Extender

3 Right Extender

4 Rear Extender

5

6

7

8

Front Extender

UEPO Switch

Rack Top Frame Left Side Cover

Rack Top Frame Right Side Cover

5

112

pSeries 690 Installation Guide

6. Remove the BPEs (item 1 in the illustration on page 113).

Note: Two people are required to remove the BPEs.

1 Bulk Power Enclosure

2 Hex Head Screw Locations

__ Step a. Remove the five hex head screws from the front BPE.

__ Step b. Remove the five hex head screws from the rear BPE.

Install (2) shipping brackets (P/N 11P2923) on both the front and rear of the frame using (8) M8X 16mm bolts (P/N 164803).

Appendix J. Removing and Installing the Rack Top Frame

113

7. To reduce the weight to the maximum two-person limit, do the following:

1 Front and Rear Rack Top

Frame Top Panels

2 Rack Top Frame

3 Left and Right BPE Rails

4

5

Foam and Metal Air Baffle

Rack Top Frame Cross Brace

__ Step a. Remove the eight screws around the perimeter of the top panels at the front and rear of the rack top frame assembly. Remove the two top

panels (item 1 in illustration in the illustration on page 114).

__ Step b. Carefully note the orientation and position of the foam and metal upright

air baffle (item 4 in the illustration on page 114) at the middle left side of

the rack top frame assembly. Remove the screw, then tilt the baffle toward the front of the rack top frame.

Note: The foam and metal upright air baffle must be reinstalled on the left side in their original location. The foam baffle is a critical part for proper cooling of the BPEs.

__ Step c. Remove the single screw at each end of the cross brace (item 5 in the

illustration on page 114). Remove the cross brace.

__ Step d. Remove the two screws at the front of the left BPE rail and remove the

rail (item 3 in illustration on page 114).

__ Step e. Remove the two screws at the rear of the right BPE rail and remove the

rail (item 3 in illustration on page 114).

114

pSeries 690 Installation Guide

4

3

2

1 Rack Top Frame

2 Rack Chassis

3

4

Top Frame Bolts

Rack Top Frame Cross Brace

8. Remove the (16) M8 X 20mm bolts (P/N 1624804)

9. Lift the rack top frame off the locating pins and remove it.

Note: Two people are required to lift and position the rack top-frame assembly.

Preparing for Rack Top Frame Installation for pSeries 690 (Reduced Height

Option) RPQ8A1173

To prepare the rack top frame for installation, do the following:

1. Unpack the frame.

2. Unpack the rack top frame.

3. Use the Jack screws to stablize and lift the rack off the floor.

__ Step a. Loosen the jam nut on each leveling foot by turning the nut counter-clockwise.

__ Step b. Rotate each leveling foot downward until it contacts the surface on which the rack is placed.

__ Step c. Adjust the leveling feet downward as needed until the rack is level.

When the rack is level, tighten the jam nuts against the base by turning the nut clockwise.

Appendix J. Removing and Installing the Rack Top Frame

115

4. Remove the front and rear BPRs, BPDs, BPCs, and the fan assemblies.

Attention:

Make note of location identification of the BPRs and BPEs for later reinstallation. The pSeries 690 will not power on if these components are not reinstalled in their original location.

1

2

3

4

5

6

1 BPE

2 BPD

3 BPC

4

5

6

BPR

BPF

Fan Cover Plate a. Remove the BPRs (item 4 in previous illustration) as follows:

__ Step 1) Make sure the ON/OFF switch is in the UNLOCK/OFF position.

__ Step 2) Loosen the thumbscrew on each side of the BPR using the torque tool (PN6422789).

__ Step 3) Rotate the release levers up on each side of the BPR. This will unseat the BPR.

__ Step 4) Pull the BPR straight out from the Bulk Power Enclosure (BPE).

__ Step 5) Repeat for the other BPRs. There can be up to six BPRs, with three in front and three in back.

b. Remove the Bulk Power Controllers (BPCs) (item 3 in previous illustration) as follows:

__ Step 1) Loosen the thumbscrew on each side of the BPC using the torque tool (PN6422789).

__ Step 2) Pull the BPC straight out from the Bulk Power Enclosure.

__ Step 3) Repeat for the other BPC. There are two BPCs, with one in front and one in back.

c. Remove the BPDs (Item 2 in the previous illustration), as follows:

__ Step 1) Loosen the thumbscrew on each side of the BPD using the torque tool (PN6422789).

__ Step 2) Pull the BPD straight out from the Bulk Power Enclosure (BPE).

__ Step 3) Repeat for the other BPDs. There can be up to four BPDs, with two in front and two in back.

d. Remove the BPF (Item 5 in the illustration on page 116) as follows:

Note: A grille covers the fan on the front the fan assembly.

1) Locate the BPF to be replaced.

2) Remove the fan cover plate (Item 6 in the illustration on page 116).

116

pSeries 690 Installation Guide

3) Loosen the upper and lower fasteners using the torque tool (PN6422789).

4) Pull the BPF straight out of the BPE.

5) Repeat for the other BPF. There are two BPFs, one in front and one in back.

e. Remove any front and rear bulk power fillers.

5. To reduce the weight to the maximum two-person limit, do the following:

4

3

2

1 Front and Rear Rack Top

Frame Top Panels

2 Rack Top Frame

3 Left and Right BPE Rails

4

5

Foam and Metal Air Baffle

Rack Top Frame Cross Brace

Appendix J. Removing and Installing the Rack Top Frame

117

__ Step a. Remove the two screws at the left and right of the top frame side

covers (items 7 and 8 in the illustration on 112).

__ Step b. Lift off the covers.

__ Step c. Remove the eight screws around the perimeter of the top panels at the front and rear of the rack top frame assembly. Remove the two top

panels (item 1 in illustration in the illustration on page 117).

__ Step d. Carefully note the orientation and position of the foam and metal upright

air baffle (item 4 in the illustration on page 117) at the middle left side of

the rack top frame assembly. Remove the screw, then tilt the baffle toward the front of the rack top frame.

Note: The foam and metal upright air baffle must be reinstalled on the left side in their original location. The foam baffle is a critical part for proper cooling of the BPEs.

__ Step e. Remove the single screw at each end of the cross brace (item 5 in the

illustration on page 117). Remove the cross brace.

__ Step f. Remove the two screws at the front of the left BPE rail and remove the

rail (item 3 in illustration on page 117).

__ Step g. Remove the two screws at the rear of the right BPE rail and remove the

rail (item 3 in illustration on page 117).

4

3

2

1 Rack Top Frame

2 Rack Chassis

118

pSeries 690 Installation Guide

3

4

Top Frame Bolts

Rack Top Frame Cross Brace

Proceed to “Installing the Rack Top Frame”.

Installing the Rack Top Frame

1. If you have not done so, use the Jack screws to stabilize and lift the rack off the floor.

__ Step a. Loosen the jam nut on each leveling foot by turning the nut counter-clockwise.

__ Step b. Rotate each leveling foot downward until it contacts the surface on which the rack is placed.

__ Step c. Adjust the leveling feet downward as needed until the rack is level.

When the rack is level, tighten the jam nuts against the base by turning the nut clockwise.

1

2 3

1 Jam Nut

2 Leveling Foot

3

Rack Base

2. Position the rack top frame on top of the rack by orienting the two front labels on the rack top frame assembly and the frame. As you are facing the frame, this label is on the right front of the frame.

Note: Two people are required to lift and position the top frame assembly. To assist with the installation a step ladder and ladder are provided with the

Appendix J. Removing and Installing the Rack Top Frame

119

reduced height option (RPQ8A1173) ship group.

4

3

2

1 Rack Rack Top Frame

2 Rack Chassis

3

4

Top Frame Bolts

Rack Top Frame Cross Brace

120

pSeries 690 Installation Guide

__ Step a. Align the rack top frame with the four alignment guides on top of the rack.

__ Step b. Fasten the rack top frame to the rack, using (16) M8 X 20mm bolts

(P/N 1624803). Tighten the bolts securely to ensure solid contact along the mating surfaces of the rack and the rack top frame.

Appendix J. Removing and Installing the Rack Top Frame

121

3. Install the front and rear top panels (item 1 in illustration on page 122) for the rack

top frame.

4. Install the left and right BPE rails, (item 3 in the illustration on page 122).

1 Front and Rear Rack Top

Frame Top Panels

2 Rack Top Frame

3 Left and Right BPE Rails

4

5

Foam and Metal Air Baffle

Rack Top Frame Cross Brace

5. Insert and align the foam air baffle (item 4 in the illustration on page 122) to the

left side of the rack top frame, securing it in place with a screw.

6. Install the rack top frame cross brace (item 5 in the illustration on page 120).

7. Install the front and rear BPEs (item 1 in the illustration on page 122).

1

2

3

4

5

6

1 BPE

2 BPD

3 BPC

4

5

6

BPR

BPF

Fan Cover Plate

8. Install the BPRs (item 4 in illustration on page 122) as follows:

__ Step a. Make sure the ON/OFF switch is in the UNLOCK/OFF position.

__ Step b. Push the BPR straight into the Bulk Power Enclosure (BPE).

__ Step c. Tighten the thumbscrew on each side of the BPR using the torque tool

(PN6422789).

__ Step d. Rotate the release levers down on each side of the BPR.

__ Step e. Repeat for the other BPRs. There can be up to six BPRs, with three in front and three in back.

9. Install the Bulk Power Controllers (BPCs) as follows:

122

pSeries 690 Installation Guide

__ Step a. Push the BPC straight into the Bulk Power Enclosure (BPE).

__ Step b. Tighten the thumbscrew on each side of the BPC using the torque tool

(PN6422789).

__ Step c. Repeat for the other BPCs. There are two BPCs, with one in front and one in back.

10. Install the BPDs as follows:

__ Step a. Push the BPD straight into the Bulk Power Enclosure (BPE).

__ Step b. Tighten the thumbscrew on each side of the BPD using the torque tool

(PN6422789).

__ Step c. Repeat for the other BPDs. There can be up to four BPDs, with two in front and two in back.

11. Install the BPFs (Item 5 in the illustration on page 122) as follows:

Note: A grille covers the fan on the front the fan assembly.

a. Locate the BPF to be installed.

b. Install the fan cover plate (Item 6 in the illustration on page 122).

c. Push the BPF straight out of the BPE.

d. Tighten the upper and lower fasteners using the torque tool (PN6422789)..

e. Repeat for the other BPF. There are two BPFs, one in front and one in back.

12. Install any front and rear bulk power fillers.

Appendix J. Removing and Installing the Rack Top Frame

123

13.

For the reduced height option, remove the front and rear upper shipping bars

(item 1 in the next illustration).

1

1 Shipping Bars

14. Install left and right top frame side covers (items 7 and 8 in the following illustration).

15. Attach all removed cables to the BPD. If an IBF exists, also attach all removed

cables for the BPC and the BPR. For cabling instructions, see Appendix H,

“Cabling Information” on page 95and Appendix G, “Subsystem Positioning and

Cabling” on page 83.

124

pSeries 690 Installation Guide

16. Install the frame extenders.

1

2

3

4

7

8

5

1 Top Extender

2 Left Extender

3 Right Extender

4 Rear Extender

5

6

7

8

Front Extender

UEPO Switch

Left Side Cover

Right Side Cover

Appendix J. Removing and Installing the Rack Top Frame

125

|

|

17. Install the UEPO switch: v

Install the top and bottom screws. Screws should be bottomed against the end of the slot prior to tightening.

v

Plug in the cables.

Cover Replacement

Refer to 107 while performing this task.

1. Examine the bottom of the frame side. There will be (2)

U

″ brackets installed at the bottom. These correspond to open slots in the bottom of the covers.

2. Always install the left side cover first.

3. Lift the cover and engage the slot into the

U

″ bracket, holding the cover at about a

30 degree angle with the top away from the frame.

4. Install the top (3) screws (P/N 54G2882). The use of a step ladder is recommended for this procedure. Push against the top of the cover to compress the gasketing to allow alignment with the tapped holes in the top of the frame.

5. Install the (2) inside screws and washers (P/N’s 77G0599 and 1625437).

6. Install the right side cover into the

U

″ bracket while holding it an angle away from the frame.

7. Since the right side cover has tab features that engage behind the left side cover, the cover must be rocked to the right from the top to clear the left side cover. After clearing the cover with the tabs, push the cover against the frame while rocking it back to the left. The cover should rest on the

U

″ bracket. The top flange should rest on the frame and the tabs should bepositioned behind the left hand cover.

Note: The covers should be flush in the middle with a small gap between them.

8. Repeat steps 4 and 5.

126

pSeries 690 Installation Guide

Index

Numerics

128-port adapter cables

connecting 71

8-port adapter cables

connecting 66

A

about this book xiii

acoustical noise

emissions 48

adapter

128-port 71

8-port 66

B

battery

disposal, recycling 47

bolting

rack 51

C

cabling

descriptions 98

HMC 22

LAN 27

locations 98

power

connection 21

HMC 27

installation 21

second rack 11

call-in

testing 102

call-out

testing 103

circuit breaker

activate 28

configuration

CPU 77

I/O 77 memory 77

network 35

service processor

serial port 103

system

other 8

configuring

service agent 37

connecting

128-port adapter cables 71

8-port adapter cables 66

CPU

configuration 77

D

date and time

setting 28

device

records 77

devices 37 attached device setup 37 setup 37

diagnostics online

loading 31

standalone

loading 32

stopping 40

door

installation 33

E

environmental

design 47 notices 47

EPO switch 17

expansion rack

inventory 9

external cables 97

F

frame

leveling 10

H

hardware operation

verifying 31

verification

considerations 31

HMC

7, 27

128-port adapter cables

connection 71

8-port adapter cables

connection 66

cabling

22, 25

configurations 8

external

modem 26

installation 22

keyboard

connection 22

127

HMC (continued) monitor

connection 22

mouse

connection 22

power cords 27

power-on 28

HMC cabling 94

I

I/O

CPU 77

identification numbers

recording 75

install

prerequisites 8

installation

completing 33 doors 33

frame

raised floor 61

HMC 22

power cords 21

rack 51

raised floor 61

installation, system 7

installing 128–port ASYNC adapter 67

inventory

list 9 rack 9 expansion 9 system 9

L

LAN

cable 27

laser compliance statement ix laser safety information ix

leveling

rack 10

loading

online diagnostics 31

standalone diagnostic 32

M

memory

configuration 77

modem external

connection 26

N

network

configuration 35

noise emissions

acoustical 48

128

pSeries 690 Installation Guide notice

safety 16

notices

environmental 47

safety vii

O

online diagnostics

loading 31

online publications xiii

operation hardware

verifying 31

outlets 19

P

parts information

external cables 97

power cords 27

installation 21 routing 21

system

connection 21

power source 19

power-on

HMC 28

preface xiii

prerequisites

install 8

product disposal 47

publications, online xiii publications, related xiii

R

rack

bolting 51 installation 51

raised floor 61

inventory 9

leveling 10

securing 51 setup 51

top frame

removal 105 replacement 105

raised floor rack

installation 61

records

device

42, 77

system 42 updating 42

recycling 47

related publications xiii

relocation

system vii

removal

top frame 108

replacement

top frame 119

routing

power cords 21

S

safety

electrical vii

notice 16

safety notices vii

laser compliance statement ix

saving service processor settings 101

second rack

attach 11 cable 11

securing

rack 51

service agent

configuring 37

service processor

backup settings 101

call-in

test 101

call-out

test 101 checklist 101

serial port

configuration 103

setup 101 setup checklist 101 test 101

setting

the date and time 28

setup and test

service processor 101

standalone diagnostics

loading 32

stopping

diagnostics 40

switch

EPO 17

system configuration

minimum 7

other 8

inventory 9

power

connection 21

records

updating 42

relocation vii

verification

additional 40

system (continued) verification (continued)

running 39

system installation 7

system records 75 key serial number 75 machine type/model 75 serial numbers 75

T

testing the setup

call-in 102

call-out 103

time and date

setting 28

top frame

removal 108

replacement 119

trademarks xiv

U

UEPO

17, 28

updating system

records 42

V

verification system

additional 40

running 39

verifying hardware

operation 31

viewing

the date and time 28

Index

129

130

pSeries 690 Installation Guide

Readers’ Comments — We’d Like to Hear from You

pSeries 690 Installation Guide

Installation Guide

Publication No. SA38-0587-01

Overall, how satisfied are you with the information in this book?

Very Satisfied Satisfied Neutral Dissatisfied

Overall satisfaction h h

How satisfied are you that the information in this book is:

Very Satisfied Satisfied

Accurate

Complete

Easy to find

Easy to understand

Well organized

Applicable to your tasks h h h h h h

Please tell us how we can improve this book:

h h h h h h h

Neutral h h h h h h h

Dissatisfied h h h h h h

Very

Dissatisfied h

Very

Dissatisfied h h h h h h

Thank you for your responses. May we contact you?

h

Yes h

No

When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you.

Address Name

Company or Organization

Phone No.

Readers’ Comments — We’d Like to Hear from You

SA38-0587-01

IBMR

Cut or Fold

Along Line

Fold and Tape

Please do not staple

Fold and Tape

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

NO POSTAGE

NECESSARY

IF MAILED IN THE

UNITED STATES

BUSINESS REPLY MAIL

FIRST-CLASS MAIL PERMIT NO. 40 ARMONK, NEW YORK

POSTAGE WILL BE PAID BY ADDRESSEE

Information Development

Department H6DS-905-6C006

11400 Burnet Road

Austin, TX 78758-3493

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Fold and Tape

Please do not staple

Fold and Tape

SA38-0587-01

Cut or Fold

Along Line

IBMR

Part Number: 09P6530

Printed in U.S.A.

April 2002

SA38-0587-01

Was this manual useful for you? yes no