Datasheet_RFSAI

Datasheet_RFSAI
Wireless switch unit with the input RFSAI-61B
• The switching unit with 1 output channel is used for controlling appliances and lights. It is possible to connect
the existing button to the internal terminal in the wiring .
• It can be combined with Control or System units iNELS RF Control.
60mm
21mm
• The BOX design lets you mount it right in an installation box, a ceiling or controlled appliance cover.
• It enables connection of the switched load up to 16A (4.000 W).
• Function: button, impulse relay and time function of delayed start or return with time setting range of
2s-60min.
• External button is programmed as a wireless button.
• Input is not galvanic isolated.
• The switching unit may be controlled by up to 32 channels (1 channel represents 1 button on the controller).
• The programming button on the unit is also used for manual control of the output.
• Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal
repeater RFRP-20.
• Communication frequency with bidirectional protocol iNELS RF Control.
Technical parameters
RFSAI-61B/230V RFSAI-61B/120V RFSAI-61B/24V
230 V AC / 50 - 60 Hz 120 V AC / 60Hz 12-24 V AC/DC 50-60Hz
Supply voltage:
7 VA / cos φ = 0.1 7 VA / cos φ = 0.1
Apparent power:
0.7 W
0.7 W
0.7 W
Dissipated power:
+10 %; -15 %
Supply voltage tolerance:
Output
1x switching (AgSnO2)
Number of contacts:
16 A / AC1
Rated current:
4000 VA / AC1, 384 W / DC
Switching power:
30 A / <3 s
Peak current:
250 V AC1 / 24 V DC
Switching voltage:
500 mW
Min. switching power DC:
3x107
Mechanical service life:
0.7x105
Electrical service life (AC1):
Controlling
868 MHz, 915 MHz, 916 MHz
RF command from the transmitter:
button PROG (ON/OFF)
Manual control:
max. 12 m cable *
External button:
up to 200 m
Range in open space:
Other data
3V
Voltage of open contact:
Resist. of connection for closed
<1 kΩ
contact:
Resist. of connection for open
>10 kΩ
contact:
No
Galvanic isolation of input:
-15 up to + 50 °C
Operating temperature:
any
Working position:
free at lead-in wires
Mounting:
IP 30
Protection:
III.
Overvoltage category:
2
Contamination degree:
2x 0.75 mm2 , 2x 2.5 mm2
Terminals (CY wire, Cross-section):
90 mm
Terminal length:
49 x 49 x 21 mm
Dimensions:
46 g
Weight:
EN 60669, EN 300 220, EN 301 489
Related standards:
R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC)
Function
For more information, see p. 56.
Device description
Terminal for connecting
an external button
Device status indication
Programming button
(manual control ON/OFF)
Neutral conductor
Output contact relay
Phase conductor
Connection
RFSAI-61B/230V
RFSAI-61B/120V
L
N
RFSAI-61B/24V
L
N
12-24 V AC/DC
* Control button input is at the supply voltage potential.
27
Switches
Single function RFSA-11B
Function button ON/OFF
The output contact closes by pressing one button position, and opens by pressing the other button position.
Multi function RFSA-61B, RFSA-62B, RFSA-61M, RFSA-66M, RFSAI-61B, RFSC-61, RFUS-61
Function 1 - button
Function 2 - switch on
Function 3 - switch off
The output contact will be closed by pressing the button and
opened by releasing the button.
The output contact will be closed by pressing the button.
The output contact will be opened by pressing the button.
Function 4 - impulse relay
Funcion 5 - delayed off
Function 6 - delayed on
The output contact will be switched to the opposite position
by each press of the button. If the contact was closed, it will be
opened and vice versa.
The output contact will be closed by pressing the button and
opened after the set time interval has elapsed.
t = 2s...60min.
The output contact will be opened by pressing the button and
closed after the set time interval has elapsed.
t = 2s...60min.
Loadability products
RFJA-12B; RFSA-62B; RFSA-66M; RFSTI-11/G; RFGSM-220M
Load type
Contact material AgSnO2
Contact 8A
cos φ ≥ 0.95
M
AC1
AC2
250V / 8A
250V / 5A
HAL.230V
AC3
AC5a without
compensation
AC5a with compensation
AC5b
AC6a
AC7b
AC12
250V / 4A
x
x
250W
250V / 4A
250V / 1A
250V / 1A
M
M
K
Load type
Contact material AgSnO2
Contact 8A
M
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 4A
250V / 3A
30V / 8A
24V /3A
30V / 2A
30V / 8A
30V / 2A
x
AC5a with compensation
230V / 3A (690VA)
up to max input C=14uF
AC5b
AC6a
AC7b
AC12
1000W
x
250V / 3A
x
M
M
RFUS-61
Load type
Contact material AgSnO2
Contact 14A
cos φ ≥ 0.95
M
M
AC1
AC2
AC3
AC5a without
compensation
250V / 14A
250V / 5A
250V / 3A
230V / 3A (690VA)
K
Load type
Contact material AgSnO2
Contact 14A
HAL.230V
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 6A
250V / 6A
24V / 10A
24V / 3A
24V / 2A
24V / 6A
24V / 2A
x
RFSA-11B; RFSA-61B; RFSA-61M; RFSTI-11B; RFDAC-71B , RFSC-61, RFSAI-61B
Load type
Contact material AgSnO2
Contact 16A
cos φ ≥ 0.95
M
56
HAL.230V
AC1
AC2
AC3
AC5a without
compensation
250V / 16A
250V / 5A
250V / 3A
230V / 3A (690VA)
K
Load type
Contact material AgSnO2
Contact 16A
M
AC5a with compensation
230V / 3A (690VA)
up to max input C=14uF
AC5b
AC6a
AC7b
AC12
1000W
x
250V / 3A
250V / 10A
M
M
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 6A
250V / 6A
24V 10A
24V /3A
24V /2A
24V / 6A
24V / 2A
x