Vulcan Hart Gas Fully Jacketed Stationary Kettle-60 Gallon Mfg: Vulcan Hart

Vulcan Hart Gas Fully Jacketed Stationary Kettle-60 Gallon Mfg: Vulcan Hart
Vulcan Hart Gas Fully Jacketed Stationary Kettle-60 Gallon
Mfg: Vulcan Hart
Stock No. SPPP600.3a
Model: GL60E
Serial No. 14377
Vulcan Hart Gas Fully Jacketed Stationary Kettle-60 Gallon. Model: GL60E. S/N: 14377. NB: 7754.
Natural gas-fired. Input: 0.44 hp per burner (15000 BTU/hr). (8) burners natural gas system with a total of
3.58 hp (120000 BTU/hr). Kettle features a sight glass level indicator and a sloped bottom. Inlets: (1) 3/4
in. dia. NPT (female), open top. Outlets: (1) 3/4 in. dia. NPT (female), (1) 3 in. dia. valve (tank discharge),
(1) 10 in. L x 4 in. W (vapor). Overall dimensions: 55 in. diameter x 45 in. H.
Item # __________________________
C.S.I. Section 11420
GS, GL, GT SERIES
GAS FULLY JACKETED KETTLE
STANDARD FEATURES
■ Kettle fully steam jacketed.
■ Mounted on stainless steel 2" diameter legs with adjustable
flange feet.
■ Kettle interior bottom sloped to front for smooth product flow
through a mounted, tapered, plug type food product draw-off
valve of standard 2" diameter.
A2780
ISO9001
Vulcan-Hart Co.
■ Stainless steel dome shaped spring assist cover with drop type
handle.
■ Draw-off opening strainer.
■ Graduated measuring rod.
■ 15 PSI relief valve.
■ Vacuum pressure relief valve.
■ Low water cut-off control.
■ Pressure limit switch and pressure gauge.
■ Faucet bracket.
■ One year limited parts and labor warranty.
OPTIONS
■ 3" tapered, plug type draw-off valve in place of 2".
GL40
GS60
GL80
GT100
GT125
GT150
40 gallons
60 gallons
80 gallons
100 gallons
125 gallons
150 gallons
151 liters
227 liters
303 liters
379 liters
473 liters
568 liters
SPECIFICATIONS:
Gas fully jacketed stationary kettle, Vulcan Model No. ________.
Kettle is mounted on 2" diameter legs with adjustable flanged
feet. Cover to be stainless steel dome shaped with drop type
handle and insulated knob. The dish shaped interior bottom is
sloped to the front for a smooth product flow through a mounted,
tapered, 2" plug type food product draw-off valve. Draw-off
includes opening strainer. Graduated measuring rod. Furnished
standard with a 15 PSI relief valve, vacuum relief valve, thermostat with a combination gas control valve and electronic ignition,
low water cut-off control and a pressure limit switch and pressure
gauge.
CSA design certified. Classified by U L to NSF Std. #4. Meets
ASME code.
■ Change in leg height to increase clearance under draw-off
valve.
■ Condensate ring on cover hinges.
■ Swing drain collector.
■ 316 stainless steel jacket liner
■ Second year extended limited parts and labor warranty.
ACCESSORIES
■ Stainless steel draw-off extension tube.
■ (12") (18" double jointed) single pantry faucet.
■ (12") (18" double jointed) double pantry faucet.
■ Double pantry washdown hose with 16" add-on faucet with
backflow preventer.
■ Double pantry washdown hose with backflow preventer.
■ Double pantry pot filler and backflow preventer.
■ Rotating tri-basket assembly.
■ Clean-up kit to include draw-off brush, clean-up brush with
36" handle and paddle scraper with 40" handle.
■ 48" stainless steel whip.
F-31643 (10-03)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
MODELS: GS, GL, GT SERIES Gas Fully Jacketed Kettle
■ Thermostat with a combination gas control valve and electronic ignition.
GS, GL, GT SERIES
GAS FULLY JACKETED KETTLES
IMPORTANT:
1. A pressure regulator sized for this unit is included. Natural
gas 8.0" W.C. Propane 10.5" W.C.
2. Gas line connecting to unit must be 3/4" or larger. If flexible connectors
are used, the inside diameter must be at least the same as the 3/4" iron
pipe and rated for the correct gas input.
3. Requires 120 volt, 60 Hz, 1 phase electrical connection. Furnished
with 6' cord and 3 prong plug. 3 amp total draw.
4. An adequate ventilation system is required for commercial cooking
equipment. Information may be obtained by writing
to the National Fire Protection Association, Batterymarch Park, Quincy,
MA 02269. When writing refer to NFPA No. 96.
5. These units are manufactured for installation in accordance with
ANSZ223.1a (latest edition), National Fuel Gas Code. Copies may be
obtained from the American Gas Association. 1515 Wilson Blvd.,
Arlington, VA 22209.
6. Equipment Clearance:
Combustible
Non-Combustible
Rear
2"
0"
Right
0"
0"
Left
0"
0"
SERVICE CONNECTIONS:
Gas Supply: 3/4" NPT, 6" AFF, Volume per schedule.
Electric Connection: 120-1 Circuit, 0.3 KW, 16 AFF.
Water: Faucet location.
NOTE:
• Dimensions which locate the above connections have a tolerance of +
or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific
code requirements is the responsibility of the owner and installer. It is
the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited temperatures of the plastic.
• This appliance is manufactured for commercial installation only and is
not intended for home use.
BRIMFUL CAPACITIES:
Model
Gallons
Quarts
Liters
4 oz. svgs.
GL40
GS60
GL80
GT100
GT125
GT150
40
60
80
100
125
150
160
240
320
400
500
600
152
227
303
379
473
568
1280
1920
2560
3200
4000
4800
MODEL
CAPACITY
A
B
C
D
E
F
G
BTU/hr. INPUT
GL40
40 gal., 151 liters
29 (737)
48 (1219)
41 (1041)
38 (965)
14 (356)
40 (1016)
71 (1803)
105,000
GS60
60 gal., 227 liters
361/2 (927) 581/2 (1486) 48 (1219)
44 (1118)
17 (432)
39 (991)
78 (1981)
135,000
GL80
80 gal., 303 liters
361/2 (927) 581/2 (1486) 48 (1219)
44 (1118)
17 (432)
44 (1118)
83 (2108)
135,000
1
1
GT100
100 gal., 379 liters
36 /2 (927) 58 /2 (1486) 48 (1219)
44 (1118)
17 (432)
49 (1245)
88 (2235)
135,000
GT125
125 gal., 473 liters
361/2 (927) 581/2 (1486) 48 (1219)
44 (1118)
17 (432)
56 (1422)
95 (2413)
135,000
GT150
150 gal., 568 liters
361/2 (927) 581/2 (1486) 48 (1219)
44 (1118)
17 (432)
621/2 (1587) 101 (2565)
135,000
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-31643 (10-03)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement