3108
Isolated repeater / splitter
3108
– Isolation and conversion of current signals
– Slimline housing of 6 mm
– Response time <7 ms
– Splitter function: 1 in - 2 out
– Simple - no setup needed
Application
• Isolation and conversion of standard DC signals.
• Galvanic separation of analog current signals.
• Elimination of ground loops and measurement of floating
signals.
• A competitive choice in terms of both price and technology for
galvanic isolation of current signals to SCADA systems or
PLC equipment.
• Installation in ATEX Ex zone 2 / IECEx Zone 2 / FM division
2.
• Suitable for environments with high vibration stress, e.g.
ships.
Connections
Technical characteristics
• The input is protected against overvoltage and polarity error.
• Factory-calibrated measurement ranges.
• Inputs and outputs are floating and galvanically separated.
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
Output specifications
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Current output: Signal range.........................
Load (max.)....................................................
Load stability, current output..........................
Current limit....................................................
*of span..........................................................
0...20.5 mA (span)
23 mA/300 Ω
≤0.01% of span/100 Ω
≤ 28 mA
= 0...20 mA
Approvals
EMC............................................................... EN 61326-1
LVD................................................................ EN 61010-1
ATEX.............................................................. KEMA 10ATEX0147 X
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
GOST R......................................................... Yes
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
Signal / noise ratio.........................................
Response time (0...90%, 100...10%).............
Accuracy........................................................
Temperature coefficient.................................
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst.................................
16.8...31.2 VDC
0.8 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC/250 VAC (I.S.)
> 60 dB
< 7 ms
< ±0.05% of span
< ±0.01% of span / °C
< ±0.5% of span
< ±1% of span
Input specifications
Current input: Measurement
range.............................................................. 0...20.5 mA
Functional range, current
input............................................................... 0...23 mA
Input voltage drop.......................................... < 1.5 VDC