Leviton HAI 38A00 2 install manual

Leviton HAI 38A00 2 install manual
LEVITON UPB™ 8-BUTTON HOUSE CONTROLLER
Cat.No.38A00-2
Installation Instructions and User’s Guide
DI-022-HL382-05AAR2243
(38I00-2)
INSTALLATION
WARNINGS AND CAUTIONS
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and
test that power is off before wiring!
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.
ENGLISH
WARNINGS AND CAUTIONS
• Usethisdevicewithcopper or copper-clad wire only.
• Forindooruseonly.
• SAVETHESEINSTRUCTIONS.
Figure 1 - Leviton UPB™
6-Button Scene Switch
Leviton UPB™ 8-Button House Controller Overview
TheLevitonUPB™8-ButtonHouseController(Figure1)isusedtoturnonorofflightinginupto8roomsinahousewhereLeviton
UPB™ Wall Switches and Leviton UPB™ 6-Button Room Controllers have been installed. It can also be used for various other lighting
controlapplications,suchascontrolling8individualloadsorlightingscenes(on/off).ItusestheUPB™two-waypowerlinecommunication
technology to communicate with an Leviton controller, UPB™ Wall Switches, and other UPB™ devices on the network.
1
2
3
4
TheLevitonUPB™8-ButtonHouseControllerhaseightpushbuttonslabeled1,2,3,4,5,6,7,and8(althoughthesebuttonsmaybe
custom engraved). Each pushbutton is slightly backlit so that the buttons can be seen in a dark room. Depending on configuration of the
Leviton UPB™ 8-Button House Controller, one or more of the eight pushbuttons will be distinctly illuminated, indicating that one or more
lights are on in the respective room(s). If a pushbutton is not illuminated, that means all lights in the respective room are currently off.
5
6
7
8
Changing Switch Color
The color of the Leviton UPB™ 8-Button House Controller may be changed to complement the interior décor. The Leviton
UPB™ 8-Button House Controller is supplied with a white bezel. Additional colors are available; contact your Leviton
distributor for more information. When changing the bezel, make sure that the Leviton UPB™ 8-Button House Controller is
disconnected from all power, and proceed as follows:
Figure 2 – Changing
Switch Color
1. The bezel attaches to the Leviton UPB™ 6-Button Scene Switch with two small Philips head screws: one on the upperright corner and one on the lower-left corner (Figure 2).
2. Using a small-bladed Philips screwdriver, unscrew each of the two screws. Remove the bezel from the back housing.
3. Install the new bezel by aligning the mounting holes on the bezel with the installation pins on the back housing. Secure
bezel to back housing with the two Phillips screws that were removed in Step 1.
INSTALLATION INSTRUCTIONS
1. TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
2. If applicable, remove the faceplate from the existing device, remove the existing device from the wall box, and disconnect the wires
fromtheexistingdevice.Identifythe"Line"(black)and"Neutral"(white)wires.
3. Remove3/4"ofinsulationfromeachofthewiresontheLevitonUPB™8-ButtonHouseController.InstalltheLevitonUPB™8-Button
House Controller by connecting wires per wiring configuration shown in Figure 3.
4. After all connections have been made, be certain that all wire connectors are firmly attached and there is no exposed copper.
5. GentlyplacethewiresandLevitonUPB™8-ButtonHouseControllerintothewallboxwiththeONpushbuttonatthetopofdevice.
Using the supplied screws, attach the Leviton UPB™ 8-Button House Controller to the wall box.
Figure 3 – Wiring Diagram
MAIN
CIRCUIT
BREAKER
PANEL
1
2
38A00-2
8-BUTTON
HOUSE
CONTROLLER
3
4
6. Before installing the faceplate, restore power to the circuit for testing.
5
6
7. After testing the Leviton UPB™ 8-Button House Controller for proper local operation, install a Decora® faceplate over the Leviton
UPB™ 8-Button House Controller.
7
8
BLACK
The Leviton UPB™ 8-Button House Controller is designed to control up to 8 rooms of lighting using Leviton Lighting Control (HLC) but also
has several configuration options that can be enabled or modified using the UPB™ UPStart configuration software.
WHITE
120VAC
60Hz
NEUTRAL
LINE
WEB VERSION
CONFIGURING THE Leviton UPB™ 8-BUTTON HOUSE CONTROLLER
Option
Factory Default
Leviton Lighting Control (HLC)
Pushbuttons1-8
SupperToggle/Link013–Link020,respectively
Each pushbutton on the Leviton UPB™ 8-Button House Controller will toggle the
lighting loads in the respective room on and off.
Pushbuttons1-8LED
Indicators
Each LED Indicator is assigned to its pushbutton’s
Link ID
When the room is turned on using the pushbutton, the LED indicator under the
respective pushbutton is illuminated. When the room is turned off using the
pushbutton, the LED indicator under the respective pushbutton is turned off. Anytime a
lighting load in a room is turned on, the LED indicator under the respective pushbutton
(room) is illuminated. When all loads in a room are turned off, the LED indicator under
the respective pushbutton (room) is turned off.
Each LED Indicator is independent (multiple LED
indicators may be on at one time).
UPB Transmission Attempts
2
Nochange.
UPB ID
NID=255
UID=096
LevitoncontrollerconfiguresNetworkID(NID),UnitID(UID),NetworkPassword,
NetworkName,RoomName,DeviceName,etc.
LED Brightness
High
Nochange.
LED Backlighting
Enabled
Nochange.
Leviton UPB™ 8-BUTTON HOUSE CONTROLLER OPERATION
The Leviton UPB™ 8-Button House Controller has many configurable items that can be set using the UPB™ UPStart configuration software. The following describes the operation of
the Leviton UPB™ 8-Button House Controller in its factory default configuration.
Using Pushbuttons to Control Individual Lighting Loads
In its factory default configuration, all 8 pushbuttons are configured to toggle between two different actions each time a pushbutton is pressed. Likewise the LED indicator behind the
pushbutton will toggle when the pushbutton is pressed.
Linking Pushbuttons to Leviton UPB™ Wall Switch Dimmer(s)
To configure these actions, the pushbuttons on the Leviton UPB™ 8-Button House Controller must be linked to Leviton UPB™ Wall Switch Dimmer(s) as follows:
Step
Operation
1
Use the local rocker switch on the Leviton UPB™ Wall Switch Dimmer(s) to set the desired level(s).
2
TaptherockerswitchontheLevitonUPB™WallSwitchDimmer(s)five(5)timesquickly.
3
The Leviton UPB™ Wall Switch Dimmer will flash its lighting load one time and blink its LED blue, to indicate that it is ready to be linked.
4
PressthepushbuttonontheLevitonUPB™8-ButtonHouseControllerfive(5)timesquickly.
5
Each Leviton UPB™ Wall Switch will flash its lighting load one time to indicate that it is successfully linked to the pushbutton and that the new light level has been set.
Unlinking Pushbuttons from Leviton UPB™ Wall Switch Dimmer(s)
If you accidentally link the wrong pushbutton to the wrong Leviton UPB™ Wall Switch Dimmer, you can unlink them as follows:
Step
Operation
1
TaptherockerswitchonthedesiredLevitonUPB™WallSwitchDimmer(s)five(5)timesquickly.
2
The Leviton UPB™ Wall Switch Dimmer will flash its lighting load one time and blink its LED blue, to indicate that it is ready to be unlinked.
3
PressthepushbuttonontheLevitonUPB™8-ButtonHouseControllerten(10)timesquickly.
4
Each Leviton UPB™ Wall Switch will flash its lighting load one time to indicate that it is successfully unlinked.
Toggling Lighting Loads
After the pushbuttons have been linked, when a pushbutton is pressed while its LED indicator is off, the lighting loads are set to the preset lighting levels and the LED indicator is
turned on. When the pushbutton is pressed again (while its LED indicator is on), the lighting loads are turn off and the LED indicator is turned off.
Event
When LED Indicator is Off
When LED Indicator is On
Single-Tap
The Leviton UPB™ Wall Switch Dimmer(s) that are linked
to this pushbutton will go to their preset lighting levels.
The LED indicator under the pushbutton is turned on.
The Leviton UPB™ Wall Switch Dimmer(s) that are linked to this pushbutton will fade to 0% (off).
The LED indicator under the pushbutton is turned off.
DoubleTap
The Leviton UPB™ Wall Switch Dimmer(s) that are linked
tothispushbuttonwillsnapto100%(on).
The LED indicator under the pushbutton is turned on.
The Leviton UPB™ Wall Switch Dimmer(s) that are linked to this pushbutton will snap to 0% (off).
The LED indicator under the pushbutton is turned off.
Brightening and Dimming Lighting Loads
When a pushbutton is pressed and held while its LED indicator is off, the lights are brightened, until the pushbutton is released. When the pushbutton is pressed, the lights are
dimmed, until the pushbutton is released.
Event
When LED Indicator is Off
When LED Indicator is On
Hold
The Leviton UPB™ Wall Switch Dimmer(s) that are linked
to this pushbutton will brighten.
The LED indicator under the pushbutton is turned on.
The Leviton UPB™ Wall Switch Dimmer(s) that are linked to this pushbutton will dim.
The LED indicator under the pushbutton is turned off.
Release
The Leviton UPB™ Wall Switch Dimmer(s) that are linked
to this pushbutton will stop brightening.
The Leviton UPB™ Wall Switch Dimmer(s) that are linked to this pushbutton will stop dimming.
SPECIFICATIONS
Model Number
Step
Operation
1
Pressandholdthe"1"and"8"pushbuttonssimultaneouslyforatleast3seconds.
NumberofBacklit
Pushbuttons
2
AlloftheLEDindicatorswillblinktoindicatethattheLevitonUPB™8-ButtonHouseControllerisinSetupMode.
Connections
Reset to Factory Default Settings
To reset the Leviton UPB™ 8-Button House Controller to factory default settings:
Step
Operation
1
Pressandholdthe"1"and"8"pushbuttonssimultaneouslyforatleast3seconds.
2
AlloftheLEDindicatorswillblinktoindicatethattheLevitonUPB™8-ButtonHouseControllerisinSetupMode.
3
Pressandholdthe"2"and"7"pushbuttonssimultaneouslyforatleast3seconds.
4
TheLEDindicatorswillstopblinkingandthe"1"and"8"pushbuttonswillilluminatetoindicatethatithas
been reset.
NOTE: It is normal for this switch to make a slight buzzing sound during operation.
LED Indicators
Dimensions
Weight
Mounting
Input Power
InputFrequency
OperatingTemperature
38A00-2
8
18GA
Yes
4.1x1.7x1.5
0.25 lb.
WEB VERSION
SETUP MODE
To configure the Leviton UPB™ 8-Button House Controller using an Leviton controller or a PC running the UPB™ UPStart
configurationsoftware,itmustbeputintoSetupModeasfollows:
Standard J Box
120±12VAC
60±3Hz
-40°Fto104°F
FCC Compliance
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainst
harmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycause
harmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor
televisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:
- Reorient or relocate the receiving antenna.
-Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.
-Increasetheseparationbetweentheequipmentandreceiver.
-Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
FOR CANADA ONLY
Forwarrantyinformationand/orproductreturns,residentsofCanadashouldcontactLevitoninwritingatLeviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165
Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
LEVITON LIMITED WARRANTY
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manufactured by Leviton under the Leviton brand name (“Product”) will be free from defects in
material and workmanship for the time periods indicated below, whichever is shorter: • OmniPro II and Lumina Pro: three (3) years from installation or 42 months from manufacture date.
• OmniLT, Omni IIe, and Lumina: two (2) years from installation or 30 months from manufacture date. • Thermostats, Accessories: two (2) years from installation or 30 months from manufacture date.
• Batteries: Rechargeable batteries in products are warranted for ninety (90) days from date of purchase. Note: Primary (non-rechargeable) batteries shipped in products are not warranted.
Products with Windows® Operating Systems: During the warranty period, Leviton will restore corrupted operating systems to factory default at no charge, provided that the product has been used as
originally intended. Installation of non-Leviton software or modification of the operating system voids this warranty. Leviton’s obligation under this Limited Warranty is limited to the repair or replacement,
at Leviton’s option, of Product that fails due to defect in material or workmanship. Leviton reserves the right to replace product under this Limited Warranty with new or remanufactured product.
Leviton will not be responsible for labor costs of removal or reinstallation of Product. The repaired or replaced product is then warranted under the terms of this Limited Warranty for the remainder
oftheLimitedWarrantytimeperiodorninety(90)days,whicheverislonger.ThisLimitedWarrantydoesnotcoverPC-basedsoftwareproducts.Leviton is not responsible for conditions or applications
beyond Leviton’s control. Leviton is not responsible for issues related to improper installation, including failure to follow written Installation and operation instructions, normal wear and
tear, catastrophe, fault or negligence of the user or other problems external to the Product. To view complete warranty and instructions for returning product, please visit us at www.leviton.com.
Usehereinofthirdpartytrademarks,servicemarks,tradenames,brandnamesand/orproductnamesareforinformationalpurposesonly,are/maybethetrademarksoftheir
respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement.
© 2013 Leviton Mfg. Co., Inc.
For Technical Assistance Call: 800-824-3005 - www.leviton.com
DI-022-HL382-05AAR2243