null  null
05/2011
Table of
Contents
n Table of Contents
n Product
Selection
n HCM
Overview
n HCM
Certified Cabling Systems
n UTP
Copper n SFTP
Copper
n FUTP
Copper
n Special
Applications Copper
n Composite
Cable
n Indoor
Fiber Optic
n Indoor
Loose Tube No Gel Fiber Optic (NanoCore™)
n Indoor
Armored Fiber Optic
n Indoor/Outdoor
Fiber Optic
n Outside
Plant Fiber Optic (Mojave™)
n Outside
Plant Fiber Optic n Outside
Plant Armored Fiber Optic
n Color
Codes
n Code
References
n Applications
n Standards
n Glossary
n Part
Number Reference
n Installation
Reference
1
2
4
6
8
32
36
42
50
52
64
70
74
82
84
86
88
89
90
92
94
98
101
1
UTP Copper
Category 6a
Category 6
4-pair
Page 8
4-pair
Page 10
Category 5E
GoldLAN
Page 18
4-pair
Page 20
SFTP Copper
Category 7A
Page 32
GoldLAN
Page 24
Multi-pair
Page 26
4-pair
Page 28
Multi-pair
Page 30
FUTP Copper
Category 7
Category 6A
Category 6
Category 5e
Page 36
Page 38
Page 40
Page 32
Composite
Special Applications Copper
2
Category 3
Cross-Connect
Patch
Bonded Jacket
Outdoor
OmniMedia
Page 42
Page 44
Page 46
Page 48
Page 50
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Indoor Fiber
Interconnect
SingleUnit
Page 52
Page 56
Indoor Fiber
NanoCore™
MultiUnit
Page 60
Page 64
Indoor/Outdoor Fiber
Armored
Tight Buffered
Central Tube
Loose Tube
Page 70
Page 74
Page 78
Page 80
Outdoor Fiber
www.hcm.hitachi.com
Mojave™
Loose Tube
Armored
Page 82
Page 84
Page 86
3
HCM has a long history
of designing innovation into our cables. All of our
designs are carefully engineered for peak performance, ease
of use, and flexibility. No other manufacturer offers these
advantages.
Hybrid constructions
Our GoldLAN™ series of cables have been
delivering TIA compliant performance since
1996. HCM proudly introduced the industry’s
first category 6 compliant hybrid cable in 2002.
Nobody can match our hybrid cable manufacturing
experience.
Manufacturing Equipment Advantages
Our facility features state-of-the-art pair twist machinery that uses
feedback to continuously monitor and maintain line speed and twist.
HCM’s technology yields more precisely controlled pair twists and
supports total flexibility in pair lay design.
The result: HCM’s cables have the best NEXT loss and
ELFEXT headroom in the industry.
Earth Friendly
All of our cables are lead free
and compliant to EU Directive 2002/95/
EC, also known as the Restriction of
Hazardous Substances or RoHS. This
stringent regulation greatly restricts the
use of certain substances known to be
hazardous to the environment.
Cleanliness
No other cabling facility pays more
attention to product protection.
From handling raw material through
production to inventory stocking,
our cables are always protected
from dirt, debris, and damage.
You will never find an unprotected reel
of fiber optic or copper cable
on our production floor.
4
User-Friendly Reelex™
Our Reelex™ cable box was designed with both
the distributor and installer in mind. Our boxes
feature bold, easy-to-read graphics and text, two
rip-resistant handles and a conduit fill chart printed
on the backside of the box. An oversized opening
helps ensure tangle-free payout. Also, all Reelex™
cable boxes are made with a minimum of 50% post
consumer material.
On-site Copper Extrusion
HCM is one of the few twisted-pair cable
manufacturers that draws it’s own copper
conductor core. Only through this process can we
ensure that our bare copper is never exposed to
air, contaminants, corrosion, or handling damage.
Because high frequency signals travel on the
“skin” of the copper, optimum performance can
only be achieved when copper drawing is part of
the in-line cable manufacturing process.
Fiber Optic Packaging
Nobody puts more effort into fiber optic cable
protection. Our reinforced reels and reel
packing ensures that your cables arrive in
perfect condition.
Going Green
Bend Insensitive
To ensure the quality and performance of our fiber optic
cables exceeds our customer’s requirements, HCM uses
high performance optical glass from Corning Optical Fiber.
In fact, Corning’s ClearCurve® bend-insensitive glass is
standard for all OM2, OM3 and OM4 cable constructions.
Many companies are making claims of being
green, but how green are they really? To see
how green HCM is, take a tour of our facility and
see for yourself. HCM recycles 100% of all office
paper waste and cardboard waste. We separate
and recycle all manufacturing byproducts
including PVC and FEP and capture and recycle
the copper dust produced during extrusion of
our copper conductors. Even wooden pallets
find a second life. Since HCM’s facility abuts a
wetland, we voluntarily sample water quality to
ensure typical parking lot runoff isn’t impacting our
surroundings. In 2009, HCM received honorable
mention for its submission to New Hampshire’s
Governor’s Award for Pollution Prevention. And,
we will continue to find ways to make our plant
and our products better for the environment.
5
HCM Certified Cabling Systems: Ultimate Flexibility
In compliance with TIA and ISO standards requirements, Hitachi Cable
Manchester, Inc.’s cables are engineered to perform flawlessly when mated to
component compliant connecting hardware and patch cords. To support the
ultimate flexibility in infrastructure design, HCM certified systems feature an
open architecture approach to the connecting hardware selection process.
The HCM R&D Laboratory continuously evaluates and monitors connecting
hardware quality and performance. Examples of manufacturers of copper and
fiber optic connecting hardware recognized and approved for use in an HCM
Certified Cabling
System include:
ADC Telecommunications, Inc.
Belden
Corning
Hellerman Tyton Corporation
Hubbell Premise Wiring
Leviton Voice & Data
Ortronics, Inc.
OCC
Panduit Corp.
Signamax
SMP Data Communications
Systimax
The Siemon Company
Tyco Electronics Corporation
Uniprise
HCM Certified Cabling Systems are only offered through HCM
Certified Installers
HCM Certification is provided through a BICSI accredited training
program or through proof of equivalent training and certification with
other recognized organizations. Students/Attendees who successfully
demonstrate a working knowledge and understanding of the HCM
Certification Program curriculum are awarded HCM Certification. This
qualified group of installers and designers plays an integral role in the
issuance of an HCM Certified Cabling System warranty.
Who benefits from HCM Certification Training?
n Cabling Designers
n Cabling Installers and Technicians
n Contractors and Consultants
n Purchasers/System Specifiers
n End-Users
6
HCM Warranted
System Performance
HCM Certified Cabling Systems are backed by a lifetime
product performance and applications assurance warranty for
channels and permanent links featuring cables from Hitachi
Cable Manchester and HCM approved connecting hardware.
All HCM’s Lifetime Warranty elements are coordinated through
HCM headquarters to ensure one point of contact for all aspects
of warranty execution and disposition. HCM products are used
across a multitude of industries and their performance plays a
key role in the success of their users. Regardless of whether
your infrastructure is used in data storage or in monitoring a wind
turbine, you expect the very best performance from the products
you’ve chosen. At HCM, all our products are built to provide
the highest, most reliable performance possible. And, as a sign
of our confidence in our products, we back them with the best
warranty in the industry.
HCM Cabling Systems feature:
n Compliance to TIA and ISO Cabling Standards
n Lifetime Product Performance Warranty
n Lifetime Applications Support Warranty
n Open Architecture Connectivity Specification
n One Point-of-Contact for all Warranty Features
7
Supra 10G
™
Product
Highlights
Supra 10G™ (Plenum)
n RoHS compliant
HITACHI
NO. OF
PART NO.
PAIRS
(c(UL)us Listed Type CMP, CSA Type FT6)
n Tested from 1 to 500 Mhz
n UL Verified Category 6A
30218-8 n Performance that exceeds TIA and ISO Category 6A requirements
4 CALCULATED
CABLE O.D.
in. mm
CABLE
WEIGHT
lbs/1000ft kg/305m
.34 53.3
8.63 24.18
Supra 10G™ (Riser)
n Patented non-concentric design
increases Alien crosstalk performance
(c(UL)us Listed Type CMR, CSA Type FT4)
n Unique spline construction is
installation and termination
friendly
HITACHI
NO. OF
PART NO.
PAIRS
CALCULATED
CABLE O.D.
in. mm
CABLE
WEIGHT
lbs/1000ft kg/305m
Packaging
30222-8
.34
42.0
n 1,000 foot (305m) reels
To build a complete HCM part number, visit page 100.
4
8.63
19.05
Options
n CMP-50 rated cables available
n Available in a 4-pair construction
n Low smoke zero halogen available; Part
#30224-8
Features
Applications
n Including:
8
10GBASE-T 10 Gigabit Ethernet
1000BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100BASE-T Ethernet
Broadband Video
POE
POE+
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
Star Filler
Flame-retardant thermoplastic
Plenum-rated polymer
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6A
Enhanced UTP
UTP Copper
Electrical Characteristics
Input Impedance 100 ± 15Ω (.772 to 500 MHz)
100 ± 15Ω (1.0 to 100 MHz)
100 ± 20Ω (100 to 250 MHz)
100 ± 25Ω (251 to 500 MHz)
Maximum conductor resistance
9.38 Ω/100 meters @ 20°C
Maximum resistance unbalance 3%
Maximum capacitance unbalance 330 pF/100 meters
Maximum delay skew 45 ns/100 meters
Nominal velocity of propagation (NVP) riser, 68% plenum, 71%
Transmission Specifications
TIA/EIA-568-C.2­Category 6A Verified
ISO/IEC 11801, 2nd ed. Class EA Compliant
Ins. Loss
NEXT
PS NEXT
ACR
PSACR
ACRF
PS ACRF
Return Loss
Max
Min
Min
Min
Min
Min
Min
Min
1
2.1
74.3
72.3
72.2
70.2
67.8
64.8
20.0
4
3.8
65.3
63.3
61.5
59.5
55.8
52.8
23.0
8
5.3
60.8
58.8
55.5
53.5
49.7
46.7
24.5
10
5.9
59.3
57.3
53.4
51.4
47.8
44.8
25.0
16
7.5
56.2
54.2
48.7
46.7
43.7
40.7
25.0
20
8.4
54.8
52.8
46.4
44.4
41.8
38.8
25.0
25
9.4
53.3
51.3
43.9
41.9
39.8
36.8
24.3
Freq. (MHz)
31.25
10.5
51.9
49.9
41.4
39.4
37.9
34.9
23.6
62.5
15.0
47.4
45.4
32.4
30.4
31.9
28.9
21.5
100
19.1
44.3
42.3
25.2
23.2
27.8
24.8
20.1
200
27.6
39.8
37.8
12.2
10.2
21.8
18.8
18.0
250
30.9
38.1
36.4
7.2
5.5
20.1
17.1
17.3
300
34.3
37.1
35.1
2.8
0.8
18.3
15.3
16.8
400
40.1
35.3
33.3
-4.8
-6.8
15.8
12.8
15.9
500
45.3
33.8
31.8
-11.5
-13.5
13.8
10.8
15.2
*Frequencies beyond the TIA and ISO requirements are for information only. “*All values are dB/100 m.
Unique patented non-concentric
design produces Alien Crosstalk
that far exceeds the proposed
standards.
www.hcm.hitachi.com
Photo is for representation purposes only.
9
Supra 660
™
Product
Highlights
Supra™ 660 (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
(c(UL)us Listed Type CMP, CSA Type FT6)
n Tested from 1 to 660 MHz
n UL Verified Category 6
TIA PARAMETER
30016-8
4
.22
5.59
CABLE
WEIGHT
lbs/1000ft kg/305m
27.35
12.4
GUARANTEED
HEADROOM
Insertion loss
+3%
NEXT loss
+9 dB
PSNEXT loss
+9 dB
ACRF
+8 dB
PSACRF +8 dB
Packaging
Supra™ 660 (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
30022-8
4
.24
6.09
CABLE
WEIGHT
lbs/1000ft kg/305m
23.0
10.43
To build a complete HCM part number, visit page 100.
n 1,000 foot (305m)
reels
Options
n CMP-50 rated cables available
n Available in a 4-pair construction
Features
Applications
n Including:
10G BASE-T 10 Gigabit Ethernet
(limited distance)
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
Broadband Video
POE
POE+
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
Star Filler
Flame-retardant thermoplastic
Plenum-rated polymer
HCM reserves the right to revise any specifications.
10
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6
Enhanced UTP
UTP Copper
Electrical Characteristics
Input Impedance 100 ± 15Ω (1.0 to 100 MHz)
100 ± 20Ω (100 to 250 MHz)
Maximum conductor resistance 9.38 Ω/100 meters @ 20°C
Maximum resistance unbalance 5%
Maximum capacitance unbalance 330 pF/100 meters
Maximum delay skew 25 ns/100 meters
Nominal velocity of propagation (NVP) riser, 68% plenum, 70%
Transmission Specifications
TIA/EIA-568-C.2 Category 6 Verified
ISO/IEC 11801, 2nd ed. Class E Compliant
NEXT
Ins Loss
ACRF
PSACR
ACR
PSNEXT
PSACRF
Min
Std.
Min
Return Loss
Std.
Min
1
2.0
2.0
74.3 83.3
72.3 81.3
72.3 81.3
70.3 79.3
67.8 75.8
64.8
72.8
20.0
20.0
4
3.8
3.7
65.3 74.3
63.3 72.3
61.5 70.6
59.5 68.6
55.8 63.8
52.8
60.8
23.0
24.2
49.7 57.7
46.7
54.7
24.5
26.3
Freq. (MHz)
Std. Max
Std.
Min
Std.
Min
Cal.
Min
Cal.
Min
Std.
8
5.3
5.2
60.8 69.8
58.8 67.8
55.5 64.6
53.5 62.6
10
6.0
5.8
59.3 68.3
57.3 66.3
53.3 62.5
51.3 60.5
47.8 55.8
25.0
27.0
7.6
7.3
56.2 65.2
54.2 63.2
48.6 57.9
46.6 55.9
43.7 51.7
44.8
40.7
52.8
16
48.7
25.0
27.0
31.25
10.7 10.4
51.9 60.9
49.9 58.9
41.2 50.5
39.2 48.5
37.9 45.9
34.9
42.9
23.6
25.9
62.5
15.4 14.9
47.4 56.4
45.4 54.4
32.0 41.5
30.0 39.5
31.9 39.9
28.9
36.9
21.5
24.2
100
19.8 19.2
44.3 53.3
42.3 51.3
24.5 34.1
22.5 32.1
27.8 35.8
24.8
32.8
20.1
23.1
155
25.2 24.4
41.1 50.4
39.4 48.4
15.9 26.0
14.3 24.0
24.0
32.
21.0
29.0
18.8
22.0
200
29.0 28.1
39.8 48.8
37.8 46.8
10.8 20.7
8.8
18.7
21.8 29.8
18.8
26.8
18.0
21.4
250
32.8 31.9
38.3 47.3
36.3 45.3
5.5
15.4
3.5
13.4
19.8 27.8
16..8 24.8
17.3
20.9
300*
-
35.3
-
46.1
-
44.1
-
10.8
-
8.8
-
26.3
-
23.3
-
20.4
350*
-
38.6
-
45.1
-
43.1
-
6.5
-
4.5
-
24.9
-
21.9
-
20.1
400*
-
41.7
-
44.3
-
42.3
-
2.6
-
-
-
23.8
-
20.8
-
19.7
500*
-
47.5
-
42.8
-
40.8
-
-
-
-
-
21.8
-
18.8
-
19.2
555*
-
50.5
-
42.1
-
40.1
-
-
-
-
-
20.9
-
17.9
-
18.9
660*
-
55.9
-
41.0
-
39.0
-
-
-
-
-
19.4
-
16.4
-
18.5
*Frequencies beyond the TIA and ISO requirements are for information only. “*All values are dB/100 m. Supra™ 660 Power Sum NEXT loss
Hitachi Supra™ 660
cables offer +9 dB
of NEXT loss and
PSNEXT loss margin over Category 6
requirements.
www.hcm.hitachi.com
Photo is for representation purposes only.
11
Premium
Product
Highlights
Premium (Plenum)
n RoHS Compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
(c(UL)us Listed Type CMP, CSA Type FT6)
n Tested from 1 to 660 MHz
n UL Verified Category 6
TIA PARAMETER
30183-8 4 .20 5.1 CABLE
WEIGHT
lbs/1000ft kg/305m
25.35
11.5
GUARANTEED
HEADROOM
NEXT loss
+5 dB
PSNEXT loss
+5 dB
ACRF
+6 dB
PSACRF +6 dB
Packaging
n 1,000 foot (305m) reels
n 1,000 foot (305m) Reelex™ (featuring reverse sequential
numbering)
Premium (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
30212-8 4 .24 6.22 CABLE
WEIGHT
lbs/1000ft kg/305m
27.6 12.5
To build a complete HCM part number, visit page 100.
n 1,000 foot (305m) Reel-in-a-Box
Options
Features
n CMP-50 rated cables available
n Available in a 4-pair construction
Applications
n Including:
10G BASE-T 10 Gigabit Ethernet
(limited distance)
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
Broadband Video
POE
POE+
Dielectric Materials
Riser
Plenum
Primary Insulation Polyolefin High Performance Plenum-rated polymer
Overall Jacket Flame-retardant thermoplastic Low-smoke, flame-retardant thermoplastic
Star Filler Flame-retardant thermoplastic Plenum-rated polymer
HCM reserves the right to revise any specifications.
12
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6
Enhanced UTP
UTP Copper
Electrical Characteristics
Input Impedance 100 ± 15Ω (1.0 to 100 MHz)
100 ± 15Ω (100 to 250 MHz)
Maximum conductor resistance 9.38 Ω/100 meters @ 20°C
Maximum resistance unbalance 5%
Maximum capacitance unbalance 330 pF/100 meters
Maximum delay skew 25 ns/100 meters
Nominal velocity of propagation (NVP) riser, 68% plenum, 70%
Transmission Specifications
TIA/EIA-568-C.2 Category 6 Verified
ISO/IEC 11801, 2nd ed. Class E Compliant
Ins Loss
NEXT
PSNEXT
Freq. (MHz)
Std.
Max
1
2.0
2.0
74.3
79.3
72.3
77.3
4
3.8
3.7
65.3
70.3
63.3
68.7
8
5.3
5.2
60.8
65.8
58.8
10
6.0
5.8
59.3
64.3
Std.
Min
ACR
PSACR
ACRF
PSACRF
Return Loss
Min
Cal.
Min
Std.
Min
Std.
Min
Std.
Min
72.3
77.3
70.3
75.3
67.8
73.8
64.8
70.8
20.0
20.0
61.5
66.6
59.5
65.0
55.8
61.8
52.8
58.8
23.0
23.0
63.8
55.5
60.6
53.5
58.6
49.7
55.7
46.7
52.7
24.5
24.5
57.3
62.3
53.3
58.5
51.3
56.5
47.8
53.8
44.8
50.8
25.0
25.0
Std.
Min
Cal.
16
7.6
7.3
56.2
61.2
54.2
59.2
48.6
53.9
46.6
51.9
43.7
49.7
40.7
46.7
25.0
25.0
31.25
10.7
10.4
51.9
56.9
49.9
54.9
41.2
46.5
39.2
44.5
37.9
43.9
34.9
40.9
23.6
23.6
62.50
15.4
14.9
47.4
52.4
45.4
50.4
32.0
37.5
30.0
35.5
31.9
37.9
28.9
34.9
21.5
21.5
100
19.8
19.2
44.3
49.3
42.3
47.3
24.5
30.1
22.5
28.1
27.8
33.8
24.8
30.8
20.1
20.1
155
25.2
24.4
41.1
46.4
39.4
44.4
15.9
22.0
14.3
20.0
24.0
30.0
21.0
27.0
18.8
18.8
200
29.0
28.1
39.8
44.8
37.8
42.8
10.8
16.7
8.8
14.7
21.8
27.8
18.8
24.8
18.0
18.0
250
32.8
31.9
38.3
43.3
36.3
41.3
5.5
11.4
3.5
9.4
19.8
25.8
16.8
22.8
17.3
17.3
300*
-
35.3
-
42.1
-
40.1
-
6.8
-
4.8
-
24.3
-
21.3
-
16.8
350*
-
38.6
-
41.1
-
39.1
-
2.5
-
-
-
22.9
-
19.9
-
16.3
400*
-
41.7
-
40.3
-
38.3
-
-
-
-
-
21.8
-
18.8
-
15.9
500*
-
47.5
-
38.8
-
36.8
-
-
-
-
-
19.8
-
16.8
-
15.2
555*
-
50.5
-
38.1
-
36.1
-
-
-
-
-
18.9
-
15.9
-
14.9
660*
-
55.9
-
37.0
-
35.0
-
-
-
-
-
17.4
-
14.4
-
14.4
*Frequencies beyond the TIA and ISO requirements are for information only. “*All values are dB/100 m. www.hcm.hitachi.com
Photo is for representation purposes only.
13
Plus
™
Plus™ (Plenum)
Product
Highlights
(c(UL)us Listed Type CMP, CSA Type FT6)
n RoHS compliant
n Tested from 1 to 555 MHz
n UL Verified Category 6
TIA PARAMETER
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
30025-8
4
.20
5.1
CABLE
WEIGHT
lbs/1000ft kg/305m
25.35
11.5
GUARANTEED
HEADROOM
NEXT loss
+3 dB
PSNEXT loss
+3 dB
ACRF
+3 dB
PSACRF
+3 dB
Packaging
n 1,000 foot (305m) reels
n 1,000 foot (305m) Reelex™ (featuring reverse sequential numbering)
Plus™ (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
PART NO.
30024-8
NO. OF
PAIRS
in. CALCULATED
CABLE O.D.
mm
lbs/1000ft CABLE
WEIGHT
kg/305m
4
.23
23.0
5.84
10.5
To build a complete HCM part number, visit page 100.
n 1,000 foot (305m) Reel-in-a-Box
Options
Features
n CMP-50 rated cables available
n Available in a 4-pair construction
Applications
n Including:
10G BASE-T 10 Gigabit Ethernet
(limited distance)
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
Broadband Video
POE
POE+
Dielectric Materials
Riser
Plenum
Primary Insulation Polyolefin High Performance FEP
Overall Jacket Flame-retardant thermoplastic Low-smoke, flame-retardant thermoplastic
Star Filler Flame-retardant thermoplastic Plenum-rated polymer
HCM reserves the right to revise any specifications.
14
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6
UTP
UTP Copper
Electrical Characteristics
Input Impedance 100 ± 15Ω (1.0 to 100 MHz)
100 ± 15Ω (100 to 250 MHz)
Maximum conductor resistance
9.38 Ω/100 meters @ 20°C
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP) riser, 68% plenum, 70%
­Transmission Specifications
TIA/EIA-568-C.2 Category 6 Verified
ISO/IEC 11801, 2nd ed. Class E Compliant
Ins Loss
NEXT
PSNEXT
ACR
PSACR
ACRF
PSACRF
Return Loss
Freq. (MHz)
Std.
Max
Std.
Min
Std.
Min
Cal.
Min
Cal.
Min
Std.
Min
Std.
Min
Std.
Min
1
2.0
2.0
74.3
77.3
72.3
75.3
72.3
75.3
70.3
73.3
67.8
70.8
64.8
67.8
20.0
20.0
4
3.8
3.8
65.3
68.3
63.3
66.3
61.5
64.5
59.5
62.5
55.8
58.8
52.8
55.8
23.0
23.0
8
5.3
5.3
60.8
63.8
58.8
61.8
55.5
58.5
53.5
56.5
49.7
52.7
46.7
49.7
24.5
24.5
10
6.0
6.0
59.3
62.3
57.3
60.3
53.3
56.3
51.3
54.3
47.8
50.8
44.8
47.8
25.0
25.0
16
7.6
7.6
56.2
59.2
54.2
57.2
48.6
51.6
46.6
49.6
43.7
46.7
40.7
43.7
25.0
25.0
31.25
10.7
10.7
51.9
54.9
49.9
52.9
41.2
44.2
39.2
42.2
37.9
40.9
34.9
37.9
23.6
23.6
62.5
15.4
15.4
47.4
50.4
45.4
48.4
32.0
35.0
30.0
33.0
31.9
34.9
28.9
31.9
21.5
21.5
100
19.8
19.8
44.3
47.3
42.3
45.3
24.5
27.5
22.5
25.5
27.8
30.8
24.8
27.8
20.1
20.1
200
29.0
29.0
39.8
42.8
37.8
40.8
10.8
13.8
8.8
11.8
21.8
24.8
18.8
21.8
18.0
18.0
250
32.8
32.8
38.3
41.3
36.3
39.3
5.5
8.5
3.5
6.5
19.8
22.8
16.8
19.8
17.3
17.3
300*
-
36.4
-
40.1
-
38.1
-
3.7
-
-
-
21.3
-
18.3
-
16.8
350*
-
39.8
-
39.1
-
37.1
-
-
-
-
-
19.9
-
16.9
-
16.3
555*
-
52.0
-
36.1
-
34.1
-
-
-
-
-
15.9
-
12.9
-
14.9
*Frequencies beyond the TIA and ISO requirements are for information only. “*All values are dB/100 m. www.hcm.hitachi.com
Photo is for representation purposes only.
15
ECO
™
Product
Highlights
ECO™ (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested from 1 to 555 MHz
n UL Verified Category 6
n No internal pair separator
n Small outside diameter permits more cables per conduit than typical Category 6 cable
n Standard Reelex™ package made
with 100% post consumer materials.
Packaging
n 1,000 foot (305m) reels
n 1,000 foot (305m) Reelex™ (featuring reverse sequential
numbering)
n 1,000 foot (305m) Reel-in-a-Box
(c(UL)us Listed Type CMP, CSA Type FT6)
30237-8
4
.19
4.87
CABLE
WEIGHT
lbs/1000ft kg/305m
26.0
11.8
ECO™ (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
30238-8
4
.21
5.48
CABLE
WEIGHT
lbs/1000ft kg/305m
23.12
10.5
To build a complete HCM part number, visit page 100.
Note: ECO Riser will be available August, 2011
Applications
n Including:
10G BASE-T 10 Gigabit Ethernet
(limited distance)
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
Broadband Video
POE
POE+
Features
Dielectric Materials
Riser
Plenum
Primary Insulation Polyolefin High Performance FEP
Overall Jacket Flame-retardant thermoplastic Low-smoke, flame-retardant thermoplastic
Star Filler Flame-retardant thermoplastic Plenum-rated polymer
Standard Reelex™ box shown above.
HCM reserves the right to revise any specifications.
16
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6
UTP
UTP Copper
Electrical Characteristics
Input Impedance 100 ± 15Ω (1.0 to 100 MHz)
100 ± 15Ω (100 to 250 MHz)
Maximum resistance unbalance 5%
Maximum capacitance unbalance 330 pF/100 meters
Maximum delay skew 45 ns/100 meters
Nominal velocity of propagation (NVP) riser, 68% plenum, 70%
Transmission Specifications
TIA/EIA 568-C.2 Category 6 Verified ISO/IEC 11801, 2nd ed. Class E Compliant
Ins Loss
Freq. (MHz)
NEXT
PSNEXT
ACR
PSACR
ACRF
PSACRF
Return Loss
Std. Max
Std.
Min
Std.
Min
Std.
Min
Std.
Min
Std.
Min
Std.
Min
Std.
Min
1
2.0
2.0
74.3
74.3
72.3 72.3
72.3
72.3
70.3
70.3
67.8
67.8
64.8
64.8
20.0
20.0
4
3.8
3.8
65.3
65.3
63.3 63.3
61.5
61.5
59.5
59.5
55.8
55.8
52.8
52.8
23.0
23.0
8
5.3
5.3
60.8
60.8
58.8 58.8
55.5
55.5
53.5
53.5
49.7
49.7
46.7
46.7
24.5
24.5
10
6.0
6.0
59.3
59.3
57.3 57.3
53.3
53.3
51.3
51.3
47.8
47.8
44.8
44.8
25.0
25.0
16
7.6
7.6
56.2
56.2
54.2 54.2
48.6
48.6
46.6
46.6
43.7
43.7
40.7
40.7
25.0
25.0
31.25
10.7 10.7
51.9
51.9
49.9 49.9
41.2
41.2
39.2
39.2
37.9
37.9
34.9
34.9
23.6
23.6
62.5
15.4 15.4
47.4
47.4
45.4 45.4
32.0
32.0
30.0
30.0
31.9
31.9
28.9
28.9
21.5
21.5
100
19.8 19.8
44.3
44.3
42.3 42.3
24.5
24.5
22.5
22.5
27.8
27.8
24.8
24.8
20.1
20.1
200
29.0 29.0
39.8
39.8
37.8 37.8
10.8
10.8
8.8
8.8
21.8
21.8
18.8
18.8
18.0
18.0
250
32.8 32.8
38.3
38.3
36.3 36.3
5.5
5.5
3.5
3.5
19.8
19.8
16..8 16.8
17.3
17.3
300*
-
36.4
-
37.1
-
35.1
-
-
-
-
18.3
-
15.3
-
16.8
350*
-
39.8
-
36.1
-
34.1
-
-
-
-
16.9
-
13.9
-
16.3
400*
-
43.0
-
35.3
-
33.3
-
-
-
-
15.8
-
12.8
-
15.9
500*
-
48.9
-
33.8
-
31.8
-
-
-
13.8
-
10.8
-
15.2
555*
-
52.0
-
33.1
-
31.1
-
-
-
12.9
-
9.9
-
14.9
*Frequencies beyond the TIA and ISO requirements are for information only. All values are dB/100m www.hcm.hitachi.com
Photo is for representation purposes only.
17
Cat 6 Hybrid
Product
Highlights
Category 6 GoldLAN™ Hybrid (Riser)
n RoHS compliant
HITACHI
PART NO.
NO. OF
LEGS
in. CALCULATED
CABLE O.D.
mm
lbs/1000ft CABLE
WEIGHT
kg/305m
30132-16
2 legs x 4-pair
.29 x .54
7.5 x 13.7
72
33
30132-24
3 legs x 4-pair
.58
14.7
104
47
30132-32
4 legs x 4-pair
.64
16.3
132
60
30132-48
6 legs x 4-pair
.79
20.1
204
93
n Tested from 1 to 250 MHz
n The industry’s first Category 6
hybrid cable verified for conformance by an independent test lab.
n Component compliant to TIA
and ISO Category 6 hybrid
cable requirements
(c(UL)us Listed Type CMR, CSA Type FT4)
Category 6 plenum hybrid constructions available skip-wrapped only.
n Power sum compliance ensures
minimum signal corruption due to alien crosstalk
Packaging
n 1,000 foot (305m) reels
Options
n Available in 2, 3, 4 and 6 leg constructions
n Custom internal jacket colors
available
Features
2 x 4-pair
3 x 4-pair
4 x 4-pair
Dielectric Materials
Riser
Primary Insulation
Polyolefin
Star Filler
Flame-retardant thermoplastic
Overall Jacket
Flame-retardant thermoplastic
Central Filler
Flame-retardant thermoplastic
6 x 4-pair
Diagram scale approx. 2:1
18
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6
GoldLAN™ Hybrid
UTP Copper
Electrical Characteristics
Input Impedance 100 ± 15Ω (1.0 to 100 MHz)
100 ± 15Ω (100 to 250 MHz)
Maximum resistance unbalance 5%
Maximum capacitance unbalance 330 pF/100 meters
Maximum delay skew 45 ns/100 meters
Nominal velocity of propagation (NVP) 68%, riser
Transmission Specifications
TIA/EIA-568-C.2 Category 6 Verified
ISO/IEC 11801, 2nd ed. Class E Compliant
Freq. Ins. loss NEXT Loss PSNEXT
ACR PSACR ACRF PSACRF Return loss
(MHz)
1
2.0
74.3
72.3
72.3
70.3
67.8
64.8
20.0
4
3.8
65.3
63.3
61.5
59.5
55.8
52.8
23.0
8
5.3
60.8
58.8
55.5
53.5
49.7
46.7
24.5
10
6.0
59.3
57.3
53.3
51.3
47.8
44.8
25.0
16
7.6
56.2
54.2
48.6
46.6
43.7
40.7
25.0
31.25
10.7
51.9
49.9
41.2
39.2
37.9
34.9
23.6
62.5
15.4
47.4
45.4
32.0
30.0
31.9
28.9
21.5
100
19.8
44.3
42.3
24.5
22.5
27.8
24.8
20.1
200
29.0
39.8
37.8
10.8
8.8
21.8
18.8
18.0
250
32.8
38.3
36.3
5.5
3.5
19.8
16.8
17.3
All values are dB/100m www.hcm.hitachi.com
Photo is for representation purposes only.
19
350
™
Product
Highlights
350™ (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
(c(UL)us Listed Type CMP, CSA Type FT6)
n Tested from 1 to 400 MHz
n UL Verified Category 5e
TIA PARAMETER
38891-8
4
.18
4.67
CABLE
WEIGHT
lbs/1000ft kg/305m
21.0
9.5
GUARANTEED
HEADROOM
NEXT loss
+6 dB
PSNEXT loss
+6 dB
ELFEXT
+6 dB
PSELFEXT +6 dB
Return loss
N/A
Packaging
n 1,000 foot (305m) reels
n 1,000 foot (305m) Reelex™ (featuring reverse sequential
numbering)
350™ (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
PART NO.
38893-8
NO. OF
PAIRS
in. CALCULATED
CABLE O.D.
mm
lbs/1000ft CABLE
WEIGHT
kg/305m
4
.19
22.0
4.90
10.0
To build a complete HCM part number, visit page 100.
n 1,000 foot (305m) Reel-in-a-Box
Options
n CMP-50 rated cables available
n Available in a 4-pair construction
Features
Applications
n Including:
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
10 BASE-T
Broadband Video
POE
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
HCM reserves the right to revise any specifications.
20
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 5e
Enhanced UTP
UTP Copper
Electrical Characteristics
Input Impedance 100 ± 15Ω (0.772 - 100 MHz)
Maximum conductor resistance
9.38 Ω/100 meters @ 20°C
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Nominal velocity of propagation (NVP)
riser, 68% plenum, 70%
Maximum delay skew
25 ns/100 meters
Transmission Specifications
TIA/EIA-568-C.2 Category 5e Verified
ISO/IEC 11801, 2nd ed. Class D Compliant
Freq (MHz)
Std. Max
PSNEXT
NEXT
Ins Loss
Std.
Min
Std.
ACRF
PSACR
ACR
Min
Cal. Min
Cal.
Min
Std.
Min
PSACRF
Std.
Min
Return Loss
Std.
Min
1
2.0
2.0
65.3 71.3
62.3 68.3
62.9 69.3
59.9 66.3 63.8 69.8
60.8 66.8
20.0 20.0
4
4.1
4.1
56.3 62.3
53.3 59.3
51.4 58.2
48.4 55.2 51.8 57.8
48.8 54.8
23.0 23.0
8
5.8
5.8
51.8 57.8
48.8 54.8
44.9 52.0
41.9 49.0 45.7 51.7
42.7 48.7
24.5 24.5
10
6.5
6.5
50.3 56.3 47.03 53.3
42.5 49.8
39.5 46.8 43.8 49.8
40.8 46.8
25.0 25.0
16
8.2
8.2
47.2 53.2
44.2 50.2
37.3 45.0
34.3 42.0 39.7 45.7
36.7 42.7
25.0 25.0
31.25
11.7 11.7 45.8 48.9
39.9 45.9
28.8 37.2
25.8 34.2 33.9 39.9
30.9 36.9
23.6 23.6
62.5
17.0 17.0 44.3 44.4
35.4 41.4
18.0 27.4
15.0 24.4 27.9 33.9
24.9 30.9
21.5 21.5
100
22.0 22.0 35.3 41.3
32.3 38.3
8.9 19.3
5.9
16.3 23.8 29.8
20.8 26.8
20.1 20.1
155*
-
28.1
-
38.5
200*
-
32.4
-
36.8
250*
-
36.9
-
35.3
350*
-
44.9
-
33.1
400*
-
48.5
-
32.3
35.5
-
10.4
-
7.4
-
25.9
-
22.9
-
18.8
-
33.8
-
4.4
-
1.4
-
23.7
-
20.7
-
18.0
-
32.3
-
-
-
-
-
21.8
-
18.8
-
17.3
-
30.1
-
-
-
-
-
18.9
-
15.9
-
16.3
-
29.3
-
-
-
-
-
17.8
-
14.8
-
15.9
-
*Frequencies beyond the TIA and ISO requirements are for information only. All values are dB/100 m. 350™ Power Sum NEXT loss
Hitachi 350 cables offer
+6 dB of NEXT loss
and PSNEXT
loss margin over
Category 5e
requirements.
www.hcm.hitachi.com
Photo is for representation purposes only.
21
Cat 5e
Product
Highlights
Category 5e (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested from 1 to 400 MHz
n UL Verified Category 5e
Packaging
n 1,000 foot (305m) reels
n 1,000 foot (305m) Reelex™ (featuring reverse sequential
numbering)
n 1,000 foot (305m) Reel-in-a-Box
Options
n CMP-50 rated cables available
n Available in a 4-pair construction
Applications
(c(UL)us Listed Type CMP, CSA Type FT6)
39419-8
4
.18
4.57
CABLE
WEIGHT
lbs/1000ft kg/305m
21.0
9.5
Category 5e (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
PART NO.
38696-8
NO. OF
PAIRS
in. CALCULATED
CABLE O.D.
mm
lbs/1000ft CABLE
WEIGHT
kg/305m
4
.17
20.0
4.55
9.1
To build a complete HCM part number, visit page 100.
n Including:
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
10 BASE-T
Broadband Video
POE
Features
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
HCM reserves the right to revise any specifications.
22
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 5e
UTP
UTP Copper
Electrical Characteristics
Input impedance 100 ± 15Ω (0.772 to 100 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
68%, riser 70%, plenum
Transmission Specifications
TIA/EIA-568-C.2 Category 5e Verified
ISO/IEC 11801, 2nd ed. Class D Compliant
NEXT
Ins Loss
Freq. (MHz) Std. Max
Std.
Min
Std.
Min
Cal.
ACRF
PSACR
ACR
PSNEXT
Min
Cal.
Min
Std.
Min
PSACRF
Std.
Min
Return Loss
Std.
Min
1
2.0
2.0
65.3 65.3
62.3 62.3
62.9 63.3
59.9 60.3
63.8 63.8
60.8 60.8
20.0 20.0
4
4.1
4.1
56.3 56.3
53.3 53.3
51.4 52.2
48.4 49.2
51.8 51.8
48.8 48.8
23.0 23.0
8
5.8
5.8
51.8 51.8
48.8 48.8
44.9 46.0
41.9 43.0
45.7 45.7
42.7 42.7
24.5 24.5
10
6.5
6.5
50.3 50.3
47.03 47.3
42.5 43.8
39.5 40.8
43.8 43.8
40.8 40.8
25.0 25.0
16
8.2
8.2
47.2 47.2
44.2 44.2
37.3 39.0
34.3 36.0
39.7 39.7
36.7 36.7
25.0 25.0
31.25
11.7 11.7
45.8 42.9
39.9 39.9
28.8 31.2
25.8 28.2
33.9 33.9
30.9 30.9
23.6 23.6
62.5
17.0 17.0
44.3 38.4
35.4 35.4
18.0 21.4
15.0 18.4
27.9 27.9
24.9 24.9
21.5 21.5
100
22.0 22.0
35.3 35.3
32.3 32.3
8.9 13.3
5.9
10.3
23.8 23.8
20.8 20.8
20.1 20.1
155*
-
28.1
-
32.4
-
29.4
-
4.3
-
1.3
-
20.0
-
17.0
-
18.8
200*
-
32.4
-
30.8
-
27.8
-
-
-
-
-
17.8
-
14.8
-
18.0
250*
-
36.9
-
29.3
-
26.3
-
-
-
-
-
15.8
-
12.8
-
17.3
400*
-
48.5
-
26.3
-
23.3
-
-
-
-
-
11.8
-
8.8
-
15.9
*Frequencies beyond the TIA and ISO requirements are for information only. All values are dB/100m. www.hcm.hitachi.com
Photo is for representation purposes only.
23
Cat 5e Hybrid
Product
Highlights
Category 5e GoldLAN™ Hybrid (Riser)
n RoHS compliant
HITACHI
PART NO.
n Tested from 1 to 100 MHz
n Component compliant to TIA Category 5e cable requirements
n Power sum compliance ensures
minimum signal corruption due to alien crosstalk
(c(UL)us Listed Type CMR, CSA Type FT4)
NO. OF
LEGS
in. CALCULATED
CABLE O.D.
mm
lbs/1000ft CABLE
WEIGHT
kg/305m
38886-16
2 legs x 4-pair
.21 x .43
5.5 x 10.9
58
26
38886-24
3 legs x 4-pair
.46
11.7
84
38
38886-32
4 legs x 4-pair
.51
13.0
107
49
38886-48
6 legs x 4-pair
.62
15.7
168
76
Category 5e plenum hybrid constructions available skip-wrapped only.
Packaging
n 1,000 foot (305m) reels
Options
n Available in 2, 3, 4 and 6 leg constructions
n Custom internal jacket colors
available
Features
2 x 4-pair
3 x 4-pair
4 x 4-pair
Dielectric Materials
Riser
Primary Insulation
Polyolefin
Overall Jacket
Flame-retardant thermoplastic
Central Filler
Flame-retardant thermoplastic
6 x 4-pair
Diagram scale approx. 3:1
24
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 5e
GoldLAN™ Hybrid
UTP Copper
Electrical Characteristics
Input impedance 100 ± 15Ω (0.772 to 100 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
68%, riser 70%, plenum
Transmission Specifications
TIA/EIA-568-C.2 Category 5e Verified
ISO/IEC 11801, 2nd ed. Class D Compliant
Freq. Ins. loss NEXT Loss PSNEXT Loss ACR PSACR ACRF (MHz) PSACRF Return loss
1
2.0
65.3
62.3
63.3
60.3
63.8
60.8
20.0
4
4.1
56.3
53.3
52.2
49.2
51.8
48.8
23.0
8
5.8
51.8
48.8
46.0
43.0
45.7
42.7
24.5
10
6.5
50.3
47.3
43.8
40.8
43.8
40.8
25.0
16
8.2
47.2
44.2
39.0
36.0
39.7
36.7
25.0
31.25
11.7
42.9
39.9
31.2
28.2
33.9
30.9
23.6
62.5
17.0
38.4
35.4
21.4
18.4
27.9
24.9
21.5
100
22.0
35.3
32.3
13.3
10.3
23.8
20.8
20.1
All values are dB/100m. Custom configurations available
www.hcm.hitachi.com
Photo is for representation purposes only.
25
Cat 5e Multi-Pair
Product
Highlights
Category 5e Power Sum Multi-pair (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested from 1 to 100 MHz
n UL Verified Category 5e
n Power sum compliance ensures
minimum signal corruption due to alien crosstalk
Packaging
n 1,000 foot (305m) reels
Options
n Consult factory for 50-pair
design construction and availability
(c(UL)us Listed Type CMP, CSA Type FT6)
30203-50
25
.48
12.2
CABLE
WEIGHT
lbs/1000ft kg/305m
141.0
64.0
Category 5e Power Sum Multi-pair (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
PART NO.
PAIRS
CALCULATED
CABLE O.D.
in. mm
CABLE
WEIGHT
lbs/1000ft kg/305m
30093-50
25
.49
12.4
130.0
59.1
30172-100
50
.49 x 1.03
12.4 x 26.1
248.0
112.7
Applications
n Including:
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
10 BASE-T
Broadband Video
25-pair
Features
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
FEP
Central Filler
Flame-retardant thermoplastic
Plenum-rated polymer
Pair Filler
Flame-retardant thermoplastic
Plenum-rated polymer
50-pair
Diagram scale approx. 3:1
26
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 5e
Power Sum Multi-pair
UTP Copper
Electrical Characteristics
Input impedance 100 ± 15Ω (0.772 to 100 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
68%, riser 70%, plenum
Transmission Specifications
TIA/EIA-568-C.2 Category 5e Verified
ISO/IEC 11801, 2nd ed. Class D Compliant
Freq. Ins. loss NEXT Loss PSNEXT Loss ACR PSACR ACRF PSACRF Return loss
(MHz) (dB/100 m)
1
2.0
65.3
62.3
63.3
60.3
63.8
60.8
20.0
4
4.1
56.3
53.3
52.2
49.2
51.8
48.8
23.0
8
5.8
51.8
48.8
46.0
43.0
45.7
42.7
24.5
10
6.5
50.3
47.3
43.8
40.8
43.8
40.8
25.0
16
8.2
47.2
44.2
39.0
36.0
39.7
36.7
25.0
31.25
11.7
42.9
39.9
31.2
28.2
33.9
30.9
23.6
62.5
17.0
38.4
35.4
21.4
18.4
27.9
24.9
21.5
100
22.0
35.3
32.3
13.3
10.3
23.8
20.8
20.1
All values are dB/100m. www.hcm.hitachi.com
27
Cat 3
Product
Highlights
Category 3 (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested from 1 to 16 MHz
n Component compliant to TIA
Category 3 cable requirements
(c(UL)us Listed Type CMP, CSA Type FT6)
38718-8
4
.20
5.1
CABLE
WEIGHT
lbs/1000ft kg/305m
17.0
7.7
Packaging
n 1,000 foot (305m) reels
n 1,000 foot (305m) Reelex™ (featuring reverse sequential
numbering)
n 1,000 foot (305m) Reel-in-a-Box
n Available in a 4-pair construction
Applications
n Including:
Category 3 (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
PART NO.
PAIRS
30111-8
4
CALCULATED
CABLE O.D.
in. mm
.18
4.5
CABLE
WEIGHT
lbs/1000ft kg/305m
17.0
7.7
To build a complete HCM part number, visit page 100.
10 BASE-T
4/16 Mbps Token Ring
25.6 Mbps ATM
Features
Dielectric Materials
Riser
Plenum
Primary Insulation
PVC
Low-smoke, flame-retardant thermoplastic
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
HCM reserves the right to revise any specifications.
28
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 3
UTP
UTP Copper
Electrical Characteristics
Characteristic impedance 100 ± 15Ω (0.772 to 16 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Transmission Specifications
TIA/EIA-568-C.2 Category 3 Compliant
Freq. Ins. loss NEXT loss ACR structural (MHz)
return loss 1
2.6
41.3
38.7
12.0
4
5.6
32.3
26.7
12.0
8
8.5
27.8
19.3
12.0
10
9.7
26.3
16.6
12.0
16
13.1
23.2
10.1
10.0
All values are dB/100m. www.hcm.hitachi.com
Photo is for representation purposes only.
29
Cat 3 Multi-Pair
Product
Highlights
Category 3 Power Sum Multi-pair (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
CABLE
WEIGHT
lbs/1000ft kg/305m
30134-50
25
.38
9.7
106.0
48.1
30134-100
50
.20 x .50
5.1 x 12.7
197.0
89.3
30134-200
100
.69
17.5
399.0
180.9
30134-400
200
.97
24.6
807.0
366.0
n Available in 25-, 50-, 100-, 200and 300-pair constructions
30134-600
300
1.33
33.7
1196.0
542.4
n Consult factory for design and availability of 400-pair constructions
Category 3 Power Sum Multi-pair (Riser)
Applications
HITACHI
NO. OF
PART NO.
PAIRS
CALCULATED
CABLE O.D.
in. mm
CABLE
WEIGHT
lbs/1000ft kg/305m
39228-50
25
.38
9.7
100.0
45.4
39228-100
50
.20 x .50
5.1 x 12.7
194.0
88.0
39228-200
100
.69
17.5
380.0
172.3
39228-400
200
.97
24.6
751.0
340.6
39228-600
300
1.26
32.0
1100.0
498.9
n Tested from 1 to 16 MHz
Packaging
n 1,000 foot (305m) reels
Options
n Including:
10 BASE-T
4/16 Mbps Token Ring
25.6 Mbps ATM
(c(UL)us Listed Type CMP, CSA Type FT6)
(c(UL)us Listed Type CMR, CSA Type FT4)
25-pair
Features
50-pair
100-pair
200-pair
300-pair
30
Dielectric Materials
Riser
Plenum
Primary Insulation
PVC
Low-smoke, flame-retardant thermoplastic
Overall Jacket (< 100-pair)
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
Overall Jacket (> 100-pair)
Flame-retardant thermoplastic
PvDF
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 3
Power Sum Multi-pair
UTP Copper
Electrical Characteristics
Characteristic impedance 100 ± 15Ω (0.772 to 16 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Transmission Specifications
TIA/EIA-568-C.2 Category 3 Compliant
Freq. Ins. loss NEXT loss ACR structural (MHz)
return loss 1
2.6
41.3
38.7
12.0
4
5.6
32.3
26.7
12.0
8
8.5
27.8
19.3
12.0
10
9.7
26.3
16.6
12.0
16
13.1
23.2
10.1
10.0
All values are dB/100m. www.hcm.hitachi.com
Photo is for representation purposes only.
31
Cat 7A
SFTP
Product
Highlights
Cat 7 (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested to 1 GHz
n Compliant to ISO 11801 Class FA (Category 7A)
Requirements.
n Conductor pairs are individually wrapped in foil.
n Overall braid
(c(UL)us Listed Type CMP, CSA Type FT6)
30250-8
4
.33
8.50
CABLE
WEIGHT
lbs/1000ft kg/305m
62.27
28.25
Packaging
n 1,000 foot (305m) reels
Applications
n Including:
10G Base-T 10 Gigabit Ethernet
Single cable support of multiple applications such as Ethernet, CATV, Analog voice and VOIP
Future applications beyond 10 Gb/s
POE
POE+
Features
Dielectric Materials
Plenum
Primary Insulation
FEP
Overall Jacket
Low-smoke, flame-retardant thermoplastic
HCM reserves the right to revise any specifications.
32
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 7A
SFTP
SFTP Copper
Electrical Characteristics
Maximum resistance unbalance
2%
Maximum capacitance unbalance
160 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
60% Transmission Specifications
ISO/IEC 11801, 2nd ed. Category 7A Compliant
Ins. Loss NEXT
Freq. Max
(MHz)
PS NEXT
Min
Min
ACR
PSACR
Cal. Min Cal. Min
ACRF
PS ACRF TCL
ELTCTL Return Loss CA (Type1)
Min
Min
Min
Min
Min
Min
1.0
2.1
78.0
75.0
75.9
72.9
78.0
75.0
40.0
35.0
20.0
-
4.0
3.7
78.0
75.0
74.3
71.3
78.0
75.0
34.0
23.0
23.0
-
8.0
5.2
78.0
75.0
72.8
69.8
75.9
72.9
31.0
16.9
24.5
-
10.0
5.8
78.0
75.0
72.2
69.2
74.0
71.0
30.0
15.0
25.0
-
16.0
7.3
78.0
75.0
70.7
67.7
69.9
66.9
28.0
10.9
25.0
-
20.0
8.2
78.0
75.0
69.8
66.8
68.0
65.0
27.0
9.0
25.0
-
25.0
9.2
78.0
75.0
68.8
65.8
66.0
63.0
26.0
7.0
24.3
-
30.0
10.1
78.0
75.0
67.9
64.9
64.5
61.5
25.2
5.5
23.8
85.0
31.3
10.3
78.0
75.0
67.7
64.7
64.1
61.1
25.1
-
23.6
85.0
62.5
14.6
78.0
75.0
63.4
60.4
58.1
55.1
22.0
-
21.5
85.0
100.0
18.5
78.0
75.0
59.5
56.5
54.0
51.0
20.0
-
20.1
85.0
200.0
26.5
73.9
70.9
47.4
44.4
48.0
45.0
17.0
-
18.0
79.0
250.0
29.7
72.4
69.4
42.7
39.7
46.0
43.0
16.0
-
17.3
77.0
300.0
32.7
71.2
68.2
38.6
35.6
44.5
41.5
-
-
17.3
75.5
400.0
38.0
69.4
66.4
31.4
28.4
42.0
39.0
-
-
17.3
73.0
500.0
42.8
67.9
64.9
25.2
22.2
40.0
37.0
-
-
17.3
71.0
600.0
47.1
66.7
63.7
19.6
16.6
38.4
35.4
-
-
17.3
69.4
700.0
51.1
65.7
62.7
14.6
11.6
37.1
34.1
-
-
16.6
68.1
800.0
54.9
64.9
61.9
9.9
6.9
35.9
32.9
-
-
16.1
66.9
900.0
58.5
64.1
61.1
5.6
2.6
34.9
31.9
-
-
15.5
65.9
1000.0
61.9
63.4
60.4
1.5
-1.5
34.0
31.0
-
-
15.1
65.0
“*All values are dB/100 m. www.hcm.hitachi.com
Photo is for representation purposes only.
33
Cat 7 SFTP
Product
Highlights
Cat 7 (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested to 600 MHz
n Compliant to ISO 11801 Class F (Category 7)
Requirements.
n Conductor pairs are individually wrapped in foil.
n Overall braid
(c(UL)us Listed Type CMP, CSA Type FT6)
30245-8
4
.33
8.50
CABLE
WEIGHT
lbs/1000ft kg/305m
62.27
28.25
Packaging
n 1,000 foot (305m) reels
Applications
n Including:
10G Base-T 10 Gigabit Ethernet
Single cable support of multiple applications such as Ethernet, CATV, Analog voice and VOIP
Future applications beyond 10 Gb/s
POE
POE+
Features
Dielectric Materials
Plenum
Primary Insulation
FEP
Overall Jacket
Low-smoke, flame-retardant thermoplastic
HCM reserves the right to revise any specifications.
34
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 7
SFTP
SFTP Copper
Electrical Characteristics
Maximum resistance unbalance
2%
Maximum capacitance unbalance
160 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
60% Transmission Specifications
ISO/IEC 11801, 2nd ed. Category 7A Compliant
Ins.
Loss
NEXT
PS
NEXT
Freq. Max
(MHz)
Min
Min Cal. Min Cal. Min Min
Min
Min
ACR
PSACR ACRF
PS
TCL ELTCTL
ACRF
Return
Loss
CA
(Type2)
Min
Min
Min
1
2.0
78.0
75.0
76.0
73.0
78.0
75.0 40.0
35.0
20.0
4
3.7
78.0
75.0
74.3
71.3
78.0
75.0 34.0
23.0
23.0
8
5.2
78.0
75.0
72.8
69.8
77.2
74.2 31.0
16.9
24.5
10
5.9
78.0
75.0
72.1
69.1
75.3
72.3 30.0
15.0
25.0
16
7.4
78.0
75.0
70.6
67.6
71.2
68.2 28.0
10.9
25.0
20
8.3
78.0
75.0
69.7
66.7
69.3
66.3 27.0
9.0
25.0
25
9.3
78.0
75.0
68.7
65.7
67.3
64.3 26.0
7.0
24.3
-
30
10.2
78.0
75.0
67.8
64.8
65.8
62.8 25.2
5.5
23.8
55.0
31.25
10.4
78.0
75.0
67.6
64.6
65.4
62.4 25.1
23.6
55.0
62.5
14.9
75.5
72.5
60.6
57.6
59.4
56.4 22.0
21.5
55.0
100
19.0
72.4
69.4
53.4
50.4
55.3
52.3 20.0
20.1
55.0
200
27.5
67.9
64.9
40.4
37.4
49.3
46.3 17.0
18.0
49.0
250
31.0
66.4
63.4
35.5
32.5
47.3
44.3 16.0
17.3
47.0
300
34.2
65.2
62.2
31.1
28.1
45.8
42.8
17.3
45.5
400
40.0
63.4
60.4
23.4
20.4
43.3
40.3
17.3
43.0
500
45.3
61.9
58.9
16.7
13.7
41.3
38.3
17.3
41.0
600
50.1
60.7
57.7
10.6
7.6
39.7
36.7
-
17.3
39.4
-
“*All values are dB/100 m. www.hcm.hitachi.com
Photo is for representation purposes only.
35
Supra 10G
™
FUTP
Product
Highlights
Category 6A FUTP (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested from 1 to 500 MHz
n UL Verified Category 6A
n Small O.D. allows more cables
per conduit
Packaging
n 1,000 foot (305m) reels
Options
(c(UL)us Listed Type CMP, CSA Type FT6)
30233-8
4
.29
7.37
CABLE
WEIGHT
lbs/1000ft kg/305m
40.0
18.2
Category 6A FUTP (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
PART NO.
PAIRS
n Available in ISOH
30234-8
4
n Available in a 4-pair construction
To build a complete HCM part number, visit page 100.
CALCULATED
CABLE O.D.
in. mm
.29
7.37
CABLE
WEIGHT
lbs/1000ft kg/305m
36.0
16.2
Applications
n Including:
10G BASE-T 10 Gigabit Ethernet
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
Broadband Video
POE
POE+
Features
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
Star Filler
Flame-retardant thermoplastic
Plenum-rated polymer
HCM reserves the right to revise any specifications.
36
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6A
Enhanced FUTP
Electrical Characteristics
100 ± 15Ω (1.0 to 100 MHz)
100 ± 20Ω (100 to 250 MHz)
100 ± 25Ω (251 to 500 MHz)
Maximum resistance unbalance
3%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
68%, riser
70%, plenum
FUTP Copper
Input impedance Transmission Specifications
TIA/EIA-568-C.2 Category 6A Verified
ISO/IEC 11801, 2nd ed. Class E A Compliant
Ins. Loss NEXT PS NEXT
Freq. Max
(MHz)
ACR
PSACR
ACRF
PS ACRF
TCL
ELTCTL Return Loss CA (Type2)
Min
Min
Min
Min
Min
Min
Min
Min
Min
Min
1
2.1
74.3
72.3
72.2
70.2
67.8
64.8
40.0
35.0
20.0
-
4
3.8
65.3
63.3
61.5
59.5
55.8
52.8
40.0
23.0
23.0
-
8
5.3
60.8
58.8
55.4
53.4
49.7
46.7
40.0
16.9
24.5
-
10
5.9
59.3
57.3
53.4
51.4
47.8
44.8
40.0
15.0
25.0
-
16
7.5
56.2
54.2
48.8
46.8
43.7
40.7
38.0
10.9
25.0
-
20
8.4
54.8
52.8
46.4
44.4
41.8
38.8
37.0
9.0
25.0
-
25
9.4
53.3
51.3
44.0
42.0
39.8
36.8
36.0
7.0
24.3
-
30
10.3
52.1
50.1
41.9
39.9
38.3
35.3
35.2
5.5
23.8
55.0
31.25
10.5
51.9
49.9
41.4
39.4
37.9
34.9
35.1
-
23.6
55.0
62.5
15.0
47.4
45.4
32.4
30.4
31.9
28.9
32.0
-
21.5
55.0
100
19.1
44.3
42.3
25.2
23.2
27.8
24.8
30.0
-
20.1
55.0
200
27.6
39.8
37.8
12.2
10.2
21.8
18.8
27.0
-
18.0
49.0
250
31.1
38.3
36.3
7.3
5.3
19.8
16.8
26.0
-
17.3
47.0
300
34.3
37.1
35.1
2.9
0.9
18.3
15.3
-
-
16.8
45.5
400
40.1
35.3
33.3
-4.8
-6.8
15.8
12.8
-
-
15.9
43.0
500
45.3
33.8
31.8
-11.4
-13.4
13.8
10.8
-
-
15.2
41.0
*Frequencies beyond the TIA and ISO requirements are for information only. “*All values are dB/100 m. www.hcm.hitachi.com
Photo is for representation purposes only.
37
Cat 6 FUTP
Product
Highlights
Category 6 FUTP (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested from 1 to 555 MHz
n UL Verified Category 6
Packaging
n 1,000 foot (305m) reels
Options
n Available in a 4-pair construction
Applications
n Including:
10G BASE-T 10 Gigabit Ethernet
(limited distance)
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
Broadband Video
POE
POE+
(c(UL)us Listed Type CMP, CSA Type FT6)
30154-8
4
.29
7.37
CABLE
WEIGHT
lbs/1000ft kg/305m
40.0
18.2
Category 6 FUTP (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
PART NO.
PAIRS
30129-8
4
CALCULATED
CABLE O.D.
in. mm
.28
7.24
CABLE
WEIGHT
lbs/1000ft kg/305m
36.0
16.2
To build a complete HCM part number, visit page 100.
Features
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
Star Filler
Flame-retardant thermoplastic
Plenum-rated polymer
HCM reserves the right to revise any specifications.
38
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 6
FUTP
Electrical Characteristics
100 ± 15Ω (0.772 to 250 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
68%, riser
70%, plenum
FUTP Copper
Input impedance Transmission Specifications
TIA/EIA-568-C.2 Category 6 Verified
ISO/IEC 11801, 2nd ed. Class E Compliant
Ins. Loss
NEXT
PS NEXT
ACR
PSACR
ACRF
PS ACRF
Return Loss
Max
Min
Min
Min
Min
Min
Min
Min
1
2.0
74.3
72.3
72.3
70.3
67.8
64.8
20.0
4
3.8
65.3
63.3
61.5
59.5
55.8
52.8
23.0
8
5.3
60.8
58.8
55.5
53.5
49.7
46.7
24.5
10
6.0
59.3
57.3
53.3
51.3
47.8
44.8
25.0
16
7.6
56.2
54.2
48.6
46.6
43.7
40.7
25.0
31.25
10.7
51.9
49.9
41.2
39.2
37.9
34.9
23.6
62.5
15.4
47.4
45.4
32.0
30.0
21.9
28.9
21.5
100
19.8
44.3
42.3
24.5
22.5
27.8
24.8
20.1
200
29.0
39.8
37.8
10.8
8.8
21.8
18.8
18.0
250
32.8
38.3
36.3
5.5
3.5
19.8
16.8
17.3
Freq. (MHz)
350*
39.8
36.1
34.1
-
-
16.9
13.9
16.3
555*
52.0
33.1
31.1
-
-
12.9
9.9
14.9
*Frequencies beyond the TIA and ISO requirements are for information only. All values are dB/100 m. www.hcm.hitachi.com
Photo is for representation purposes only.
39
Cat 5e FUTP
Product
Highlights
Category 5e FUTP (Plenum)
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Tested from 1 to 400 MHz
n UL Verified Category 5e
Packaging
(c(UL)us Listed Type CMP, CSA Type FT6)
38653-8
4
.25
6.48
CABLE
WEIGHT
lbs/1000ft kg/305m
30.6
13.9
n 1,000 foot (305m)
reels
Options
n Available in a 4-pair construction
Applications
n Including:
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
10 BASE-T
Broadband Video
POE
Category 5e FUTP (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
NO. OF
PART NO.
PAIRS
39092-8
4
CALCULATED
CABLE O.D.
in. mm
CABLE
WEIGHT
lbs/1000ft kg/305m
.25
25.0
6.48
11.4
To build a complete HCM part number, visit page 100.
Features
Dielectric Materials
Riser
Plenum
Primary Insulation
Polyolefin
FEP
Overall Jacket
Flame-retardant thermoplastic
Low-smoke, flame-retardant thermoplastic
HCM reserves the right to revise any specifications.
40
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Category 5e
FUTP
Electrical Characteristics
100 ± 15Ω (0.772 to 100 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
68%, riser
70%, plenum
FUTP Copper
Input impedance Transmission Specifications
TIA/EIA-568-C.2 Category 5e Verified
ISO/IEC 11801, 2nd ed. Class D Compliant
Ins. Loss
Freq. (MHz)
NEXT
PS NEXT
ACR
PSACR
ACRF
PS ACRF
Return Loss
Max
Min
Min
Min
Min
Min
Min
Min
1
2.0
65.3
62.3
63.3
60.3
63.8
60.8
20.0
4
4.1
56.3
53.3
52.2
49.2
51.8
48.8
23.0
8
5.8
51.8
48.8
46.0
43.0
45.7
42.7
24.5
10
6.5
50.3
47.3
43.8
40.8
43.8
40.8
25.0
16
8.2
47.2
44.2
39.0
36.0
39.7
36.7
25.0
31.25
11.7
42.9
39.9
31.2
28.2
33.9
30.9
23.6
62.5
17.0
38.4
35.4
21.4
18.4
27.9
24.9
21.5
100
22.0
35.3
32.3
13.3
10.3
23.8
20.8
20.1
155*
28.1
32.4
29.4
4.3
1.3
20.0
17.0
18.8
200*
32.4
30.8
27.8
-
-
17.8
14.8
18.0
250*
36.9
29.3
26.3
-
-
15.8
12.8
17.3
400*
48.5
26.3
23.3
-
-
11.8
8.8
15.9
*Frequencies beyond the TIA and ISO requirements are for information only. All values are dB/100 m. www.hcm.hitachi.com
Photo is for representation purposes only.
41
Cross-Connect
Product
Highlights
n RoHS compliant
n Pairs consist of a solid color
conductor twisted with a white
conductor that is marked with
a matching color stripe
Packaging
n 1,000 foot (305m) reels
Category 6 Cross-Connect
TIA/EIA-568-C.2-1 Category 6 Compliant
ISO/IEC 11801, 2nd ed. Class E Compliant
Tested from 1 to 250 MHz
HITACHI
PART NO.
NO. OF
PAIRS
PAIR
COLOR-CODING
30110-2
1
RED
30110-2
1
BLUE
30110-4
2
BLUE, ORANGE
30110-6
3
BLUE, ORANGE, GREEN
30110-8
4
BLUE, ORANGE, GREEN, BROWN
1-pair, red
Category 5e Cross-Connect
1-pair, blue
2-pair
TIA/EIA-568-C.2 Category 5e Compliant
ISO/IEC 11801, 2nd ed. Class D Compliant
Tested from 1 to 100 MHz
HITACHI
PART NO.
NO. OF
PAIRS
PAIR
COLOR-CODING
30153-2
1
RED
30153-2
1
BLUE
30153-4
2
BLUE, ORANGE
30153-6
3
BLUE, ORANGE, GREEN
3-pair
30153-8
4
BLUE, ORANGE, GREEN, BROWN
4-pair
Category 3 Cross-Connect
TIA/EIA-568-C.2 Category 3 Compliant
Tested from 1 to 16 MHz
Diagram scale approx. 3:1
42
HITACHI
PART NO.
NO. OF
PAIRS
PAIR
COLOR-CODING
30124-2
1
RED
30124-2
1
BLUE
30124-4
2
BLUE, ORANGE
30124-6
3
BLUE, ORANGE, GREEN
30124-8
4
BLUE, ORANGE, GREEN, BROWN
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Cross-Connect
Special Applications
Features
Dielectric Materials CATEGORY 3
CATEGORY 5e AND CATEGORY 6
Primary Insulation
Polyolefin
Polyolefin
Special
Applications
Category 3
www.hcm.hitachi.com
Category 5e
Category 6
Photos are for representation purposes only.
43
Patch Cable
Product
Highlights
Category 5e Data-Master Patch
n RoHS compliant
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
n Soft, flexible jacket for ease of termination
Packaging
n 1,000 foot (305m) reels
Options
n Available in 4-pair constructions
n Custom jacket colors available
n Optional rip cord available
Tested from 1 to 100 MHz
38822-8
4
.18
4.5
CABLE
WEIGHT
lbs/1000ft kg/305m
19.0
8.6
To build a complete HCM part number, visit page 100.
Enhanced Category 5e Data-Master Patch
Tested from 1 to 100 MHz
+6 dB NEXT loss and PSNEXT loss headroom
+6 dB ELFEXT and PSELFEXT headroom
HITACHI
PART NO.
39063-8
NO. OF
PAIRS
in. CALCULATED
CABLE O.D.
mm
lbs/1000ft CABLE
WEIGHT
kg/305m
4
.19
22.0
4.7
10.4
To build a complete HCM part number, visit page 100.
Category 6 Data-Master Patch
Tested from 1 to 250 MHz
Category 5e 4-pair
Enhanced Category 5e 4-pair
Category 6 4-pair
HITACHI
PART NO.
30073-8
NO. OF
PAIRS
in. CALCULATED
CABLE O.D.
mm
lbs/1000ft CABLE
WEIGHT
kg/305m
4
.23
23.0
5.8
10.4
To build a complete HCM part number, visit page 100.
Enhanced Category 6 4-pair
Enhanced Category 6 Data-Master Patch
Tested from 1 to 250 MHz
+8 dB NEXT loss and PSNEXT loss headroom
+8 dB ELFEXT and PSELFEXT headroom
HITACHI
NO. OF
CALCULATED
PART NO.
PAIRS
CABLE O.D.
in. mm
30074-8
4
.25
6.3
CABLE
WEIGHT
lbs/1000ft kg/305m
25.0
11.3
To build a complete HCM part number, visit page 100.
Diagram scale approx. 3:1
44
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Patch Cable
Special Applications
Category 5e/Enhanced Category 5e/ Category 6
Features
Dielectric Materials Overall Jacket
Flame-retardant thermoplastic
Special
Polyolefin
Applications
Primary Insulation
Enhanced Category 6 Features
Dielectric Materials Primary Insulation
Polyolefin
Overall Jacket
Flame-retardant thermoplastic
www.hcm.hitachi.com
Photo is for representation purposes only.
45
Multi-Net
™
Product
Highlights
Multi-Net™ Bonded Jacket (Plenum)
n RoHS compliant
HITACHI
CATEGORY OF EACH
CALCULATED
PART NO.
4-PAIR UTP LEG
CABLE O.D.
in. mm
n Bonded leg constructions facilitate easier cable pulls
n Easy-tear web allows quick
cable separation in the field
Packaging
n 1,000 foot (305m) reels
Options
n Custom leg configurations
available
n 2-pair leg constructions available
(c(UL)us Listed Type CMP, CSA Type FT6)
CABLE
WEIGHT
lbs/1000ft kg/305m
TWO LEG CONSTRUCTIONS
30120
6 x 6
.24 x .49
6.1 x 12.4
56.0
25.4
38730
38733
38732
.17 x .38
.17 x .38
.17 x .37
4.4 x 9.6
4.4 x 9.6
4.4 x 9.4
45.0
42.0
36.0
20.5
19.1
16.4
.17 x .58
.17 x .58
.17 x .58
4.4 x 14.7
4.4 x 14.7
4.4 x 14.7
68.0
65.0
63.0
30.9
29.5
28.6
5e x 5e
3 x 5e
3 x 3
THREE LEG CONSTRUCTIONS
38895
5e x 5e x 5e
38740
5e x 3 x 5e
39068
3 x 5e x 3
Multi-Net™ Bonded Jacket (Riser)
(c(UL)us Listed Type CMR, CSA Type FT4)
HITACHI
CATEGORY OF EACH
CALCULATED
PART NO.
4-PAIR UTP LEG
CABLE O.D.
in. mm
2 leg, category 3/5e construction
2 leg, category 6 construction
3 leg, category 3/5e construction
Diagram scale approx. 2:1
46
CABLE
WEIGHT
lbs/1000ft kg/305m
TWO LEG CONSTRUCTIONS
30086
6 x 6
.25 x .52
6.4 x 13.2
50.0
22.7
38743
39069
39073
.18 x .38
.17 x .37
.17 x .37
4.5 x 9.7
4.4 x 9.4
4.4 x 9.4
39.0
36.0
34.0
17.7
16.3
15.4
.18 x .59
.17 x .58
.17 x .57
4.5 x 14.9
4.4 x 14.7
4.4 x 14.6
59.0
59.0
60.0
26.8
26.8
27.3
5e x 5e
3 x 5e
3 x 3
THREE LEG CONSTRUCTIONS
39074
5e x 5e x 5e
38842
5e x 3 x 5e
39075
3 x 5e x 3
Features
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Multi-Net
™
Special Applications
Transmission Specifications
Category 3 Leg
• TIA/EIA-568-C.2 Category 3 Compliant
Category 5e Leg
• TIA/EIA-568-C.2 Category 5e Compliant
• ISO/IEC 11801, 2nd ed. Class D Compliant
Category 6 Leg
• TIA/EIA-568-C.2 Category 6 Compliant
• ISO/IEC 11801, 2nd ed. Class E Compliant
Special
Applications
www.hcm.hitachi.com
Photo is for representation purposes only.
47
Outdoor Cable
Product
Highlights
n RoHS compliant
n Suitable for direct burial, lashed
aerial, duct and underground
conduit applications
n Cable core is filled with non-conductive, water- blocking gel
n Rugged black polyolefin jacket
n UV resistant jacket
Category 5e and Category 6 Outdoor
HITACHI
NO. OF
CALCULATED CABLE
PART NO.
PAIRS
CABLE O.D.
in. mm
Category 5e WEIGHT
lbs/1000ft kg/305m
30145-8
4
0.23
5.8
31.0
14.1
Category 6 30180-8
4
0.24
6.2
35.0
15.9
To build a complete HCM part number, visit page 100.
Packaging
n 1,000 foot (305m) reels
Options
Features
n Category 3 outdoor cables available
n Available in a 4-pair construction
Applications
n Including:
10G BASE-T 10 Gigabit Ethernet
(limited distance for Cat 6 only)
1000 BASE-T Gigabit Ethernet
1000 Mbps ATM
622 Mbps ATM
100 BASE-T Ethernet
Broadband Video
Category 5e
Category 6
Dielectric Materials Outdoor utp cables
Primary Insulation
Polyolefin
Overall Jacket
Medium density polyolefin
HCM reserves the right to revise any specifications.
48
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Outdoor Cable
Special Applications
Electrical Characteristics
Input impedance 100 ± 15 Ω (1.0 to 100 MHz)
100 ± 15 Ω (100 to 250 MHz)
Maximum resistance unbalance
5%
Maximum capacitance unbalance
330 pF/100 meters
Maximum delay skew
45 ns/100 meters
Nominal velocity of propagation (NVP)
63%
Transmission Specifications
TIA/EIA-568-C.2 Category 5e Compliant
ISO/IEC 11801, 2nd ed. Class D Compliant
Freq. Ins. loss loss
(MHz) (dB/100 m)
ACR PSACRF ACRF PSACRF Return
loss (dB)
loss (dB)
(dB)
(dB)
(dB)
(dB)
(dB)
63.3
52.2
46.0
43.8
39.0
31.2
21.4
13.3
4.3
-
-
-
60.3
49.2
43.0
40.8
36.0
28.2
18.4
20.8
1.3
-
-
-
63.8
51.8
45.7
43.8
39.7
33.9
27.9
23.8
20.0
17.8
15.8
11.8
60.8
48.8
42.7
40.8
36.7
30.9
24.9
20.6
17.0
14.8
12.8
8.8
20.0
23.0
24.5
25.0
25.0
23.6
21.5
20.1
18.8
18.0
17.3
15.9
65.3
56.3
51.8
50.3
47.2
42.9
38.4
35.3
32.4
30.8
29.3
26.3
62.3
53.3
48.8
47.3
44.2
39.9
35.4
32.3
29.4
27.8
26.3
23.3
Special
2.0
4.1
5.8
6.5
8.2
11.7
17.0
22.0
28.1
32.4
36.9
48.5
PSNEXT
Applications
1
4
8
10
16
31.25
62.5
100
155*
200*
250*
400*
NEXT *Frequencies beyond the TIA and ISO requirements are for information only. “*All values are dB/100 m
Transmission Specifications
TIA/EIA-568-C.2 Category 6 Compliant
ISO/IEC 11801, 2nd ed. Class E Compliant
Freq. Ins. loss (MHz) (dB/100 m)
1
4
8
10
16
31.25
62.5
100
200
250
350*
555*
2.0
3.8
5.3
6.0
7.6
10.7
15.4
19.8
29.0
32.8
39.8
52.0
NEXT loss (dB)
75.3
66.3
61.8
60.3
57.2
52.9
48.4
45.3
40.8
39.3
37.1
34.1
PSNEXT
loss (dB)
73.3
64.3
59.8
58.3
55.2
50.9
46.4
43.3
38.8
37.3
35.1
32.1
ACR (dB)
73.3
62.5
56.5
54.3
49.6
42.2
33.0
25.5
11.8
6.5
-
-
PSACRF (dB)
ACRF (dB)
71.3
60.5
54.5
52.3
47.6
40.2
31.0
23.5
9.8
4.5
-
-
70.8
58.8
52.7
50.8
46.7
40.9
34.9
30.8
24.8
19.8
19.9
15.9
PSACRF Return loss
(dB)
(dB)
67.8
55.8
49.7
47.8
43.7
37.9
31.9
27.8
21.8
16.8
16.9
12.9
20.0
23.0
24.5
25.0
25.0
23.6
21.5
20.1
18.0
17.3
16.3
14.9
*Frequencies beyond the TIA and ISO requirements are for information only. All values are dB/100m.
www.hcm.hitachi.com
Photo is for representation purposes only.
49
Hybrid/Bundled
Product
Highlights
n Perfect for use when mixed
fiber optic and/or copper
media and coaxial cable is required
n Suitable for use in residential
applications
n Supports reduced installation
costs and simpler cable management
Packaging
n 1,000 foot (305m) reels
n 500 foot (152m) reels
Options
n Dual- and Tri-shield RG-6
coaxial cables available
n Custom legends and jacket colors, including our innovative integrated jacket stripe, available Telecommunications standards recognize hybrid and bundled cable for use in a variety of
applications. Beginning with premium twisted-pair and fiber optic cables, HCM can manufacture virtually any standard’s compliant hybrid or bundled cable assembly. No other cable supplier can match
our hybrid and bundled cable manufacturing expertise.
What is the difference between a hybrid and a bundled cable? According to the TIA definitions, the
key difference is that an overall flame-retardant thermoplastic jacket covers a hybrid cable, while a
skip-wrap or binding secures the cables in a bundled design.
hybrid cable: An assembly of two or more cables, of the same or different types or categories,
covered by one overall sheath.
bundled cable: An assembly of two or more cables continuously bound together to form a
single unit.
Since hybrid and bundled cables represent a custom construction, HCM’s customer service
representatives are available to help you design your solution. You should have the following
information available before contracting our team of experts:
Construction Type (Hybrid or Bundled):
Flame Rating (General, Riser, or Plenum):
Use (Indoor, Indoor/Outdoor, OSP):
Number of Legs:
Category or Fiber Type
# of Fibers or Pairs
Jacket color and/or
custom designation
Leg 1
Leg 2
Leg 3
Unlimited jacket colors and
identification schemes.
Leg 4
Leg 5
Leg 6
Examples of our most popular fiber hybrid constructions include:
Speed pull design allows multiple cables
to be pulled simultaneously.
Example of a composite fiber and copper
cable that features an overall jacket
and integrated stripe.
Diagram scale approx. 3:1
HITACHI PART NO.
# OF PAIRS
OR FIBERS
CABLE TYPE
FIRE RATING/USE
60056-18 Leg 1
Leg 2
12
6
62.5/125 µm Multimode
8.3/125 µm Singlemode
CMP Indoor
60052-24 Leg 1
Leg 2
12
12
62.5/125 µm Multimode
8.3/125 µm Singlemode
CMR Indoor
60116-18 Leg 1
Leg 2
12
6
62.5/125 µm Multimode
8.3/125 µm Singlemode
CMR Indoor/ Outdoor
60150-12 Leg 1
Leg 2
6
6
62.5/125 µm Multimode
8.3/125 µm Singlemode
Outside Plant
60136-36 Leg 1
Leg 2
24
12
62.5/125 µm Multimode
8.3/125 µm Singlemode
Outside Plant
60145-72 Leg 1
Leg 2
48
24
62.5/125 µm Multimode
8.3/125 µm Singlemode
Outside Plant
HCM reserves the right to revise any specifications.
50
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
OMNIMedia
™
Features
OMNIMedia™ (Riser)
(sample construction)
(CMR, CSA Type FT4)
OMNIMedia cables are hybrid solutions specifically designed to support mixed media
applications, such as residential, requiring quad-shield RG-6 coaxial cables, fiber optic, and/or twisted-pair copper cables under an overall jacket. All OMNIMedia constructions are manufactured with
TIA component-compliant cables and are suitable for use in riser-rated
applications.
Examples of our most popular OMNIMedia constructions include:
CABLE
O.D.
in.
mm
CABLE WEIGHT
lbs/1000ft kg/1000m
30125-17 Leg 1
Leg 2
Leg 3
4-Pair
4-Pair
-
Category 5e, blue jacket
Category 5e, gray jacket
RG-6 Quad Shield, black jacket
.550
14.0
114.0
51.7
30125-18
Leg
Leg
Leg
Leg
1
2
3
4
4-Pair
4-Pair
-
-
Category 5e, blue jacket
Category 5e, gray jacket
RG-6 Quad Shield, black jacket
RG-6 Quad Shield, white jacket
.650
16.5
154.0
79.8
61321-20
Leg
Leg
Leg
Leg
Leg
1
2
3
4
5
4-Pair
4-Pair
-
-
2-fiber
Category 5e, blue jacket
.660
Category 5e, gray jacket
RG-6 Quad Shield, black jacket
RG-6 Quad Shield, white jacket
62.5/125 µm Multimode, orange jacket
16.8
161.0
73.0
61355-20
Leg
Leg
Leg
Leg
Leg
Leg
1
2
3
4
5
6
4-Pair
4-Pair
-
-
1-fiber
1-fiber
Category 5e, blue jacket
.650
Category 5e, gray jacket
RG-6 Quad Shield, black jacket
RG-6 Quad Shield, white jacket
62.5/125 µm Multimode, orange jacket
62.5/125 µm Multimode, orange jacket
16.5
163.0
73.9
Composite
HITACHI
# OF PAIRS
CABLE
PART NO.
OR FIBERS
TYPE
Cables
Standard OMNIMedia cables without fiber optic legs feature an overall blue jacket. OmniMedia cables
containing fiber optic legs feature an overall orange jacket. Contact our customer service team to
design your own custom OMNIMedia solution.
Transmission Specifications
Nominal ODs
Nom.
in. mm.
Nom. Vel. Prop.
83%
Nom. Capacitance pF/ft. pF/m
16.3
53.5
Nom. Attenuation
MHz dB/100ft dB/100m
Cond. .040
1.02
5
0.6
2.0
Dielec. .180
4.57
10
0.8
2.6
Final
7.57
.298
75
RG-6 Quad Shield Cable
50
1.5
4.9
100
2.1
6.9
Construction: RG-6/U Type Quad Shield Broadband Coaxial Cable,
18
AWG Solid Copper Covered Steel Conductor, 36ž/kft, 118ž/km.
Cellular
Polyethylene Dielectric. Quad Shielded, Bonded Aluminum Foil,
60%
Aluminum Braid, Aluminum Foil, 40% Aluminum Braid. Overall
PVC Jacket.
200
2.8
9.2
400
4.2
13.8
700
5.6
18.4
900
6.3
20.7
1000
6.7
22.0
www.hcm.hitachi.com
51
Interconnect
1-fiber, 2-fiber and zip
Product
Highlights
n RoHS compliant
n 900 µm buffered design recommended for easy termination
n OM2, OM3 & OM4 cables utilize Corning ClearCurve glass
Interconnect (Riser)
(UL) OFNR c(UL) FT4
Fiber Count
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
1
1
1
1
2
2
2
zip
60001-1
60037-1
60038-1
60425-1
60514-2
60001-2
61512-2
60005-2
60004-1
60003-1
60002-1
60462-1
60063-2
60004-2
61510-2
60007-2
60464-1
60465-1
60466-1
60467-1
60463-2
60464-2
61511-2
60501-2
61790-1
61791-1
61792-1
61793-1
61838-2
61842-2
61843-2
61844-2
60040-1
60039-1
60010-1
60489-1
60012-2
60040-2
61515-2
60011-2
61653-1
61655-1
61657-1
61659-1
61653-2
61661-2
61663-2
61665-2
n Ideal for patch cords, interconnections, and short runs
n Easy to strip and terminate
n Lightweight, flexible aramid
yarns enhance strength
n Extremely flexible for easy handling
Options
n Cables with 600 micron buffer
available
n Low smoke zero halogen available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit - other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
I
ISO/ IEC 11801, 2nd edition
HCM Fiber
Max Attenuation (dB/
Performance
Km)
Parameters
1-fiber Interconnect
2-fiber Interconnect
Min Bandwidth OFL
MHz-Km
I
Telcordia GR-409-CORE
Min Bandwidth*
MHz-Km
Gigabit Ethernet
Support Distance
(meters)
10 Gigabit Ethernet
Support Distance
(meters)
850 nm
1300 nm
850 nm
1300 nm
850 nm
1300 nm
850 nm
1300 nm
850 nm
1300 nm
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
2-fiber Zip Cord
1310 nm
1550 nm
OS2
0.50
0.50
OS2 BI**
0.50
0.50
**OS2 BI utilizes bend-insensitive optical glass
Diagram scale approx. 5:1
52
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Interconnect
Multimode and Singlemode
(UL) OFNR us FT4
FIBER COUNT
1
1
1
1
2
2
2
zip
CABLE O.D. in.
mm
0.114
2.9
0.094
2.4
0.083
2.1
0.063
1.6
0.190
4.8
0.114
2.9
0.098
2.5
.113 x .140 2.9 x 6.1
MAXIMUM LOAD
INSTALL
lbs-f
96
96
48
48
128
96
96
128
N
427
427
213
213
569
427
427
569
CABLE WEIGHT
n Bend radius, no load = 10x cable overall diameter
lbs/1000 ft kg/1000m
4.9
7.2
1.2
4.2
3.2
4.7
1.8
1.8
11.5
17.1
4.9
7.2
4.0
5.9
11.5
17.1
n Bend radius, load = 15x cable overall diameter
OPERATION
lbs-f
48
48
24
24
64
48
48
64
N
213
213
106
106
284
213
213
284
Indoor
Mechanical
Specifications
Interconnect (Riser)
10 Gigabit Applications
IEEE standard
Wavelength
Transmission
10GBASE-SR
850nm
Serialized
10GBASE-LR
1310nm
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielect­­­­ric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
53
Interconnect
1-fiber, 2-fiber and zip
Product
Highlights
n RoHS compliant
n 900 µm buffered design recommended for easy termination
n OM2, OM3 & OM4 cables utilize Corning ClearCurve glass
Interconnect (Plenum)
(UL) OFNP c(UL) FT6
1
1
1
1
2
2
2
62.5 UM
OM1
60042-1
60430-1
60431-1
60432-1
60024-2
60042-2
61461-2
50 UM
OM2
60022-1
60468-1
60469-1
60470-1
60026-1
60022-2
61492-2
50 UM
OM3
60472-1
60473-1
60474-1
60475-1
60471-2
60472-2
61488-2
50 UM
OM4
61851-1
61852-1
61853-1
61854-1
61851-2
61855-2
61856-2
8.3 UM
OS2
60044-1
60490-1
60491-1
60492-1
60031-2
60044-2
61493-2
8.3 UM
OS2BI
61679-1
61681-1
61683-1
61685-1
61679-2
61687-2
61689-2
zip
60023-2
60008-2
60502-2
61857-2
60030-2
61691-2
Fiber Count
n Ideal for patch cords, interconnections, and short runs
n Easy to strip and terminate
n Lightweight, flexible aramid
yarns enhance strength
n Extremely flexible for easy handling
Options
n Cables with 600 micron buffer
available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit - other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
I
ISO/ IEC 11801, 2nd edition
HCM Fiber
Max Attenuation (dB/
Performance
Km)
Parameters
1-fiber Interconnect2-fiber Interconnect
Min Bandwidth OFL
MHz-Km
I
Telcordia GR-409-CORE
Min Bandwidth*
MHz-Km
Gigabit Ethernet
Support Distance
(meters)
10 Gigabit Ethernet
Support Distance
(meters)
850 nm
1300 nm
850 nm
1300 nm
850 nm
1300 nm
850 nm
1300 nm
850 nm
1300 nm
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
2-fiber Zip Cord
1310 nm
1550 nm
OS2
0.50
0.50
OS2 BI**
0.50
0.50
**OS2 BI utilizes bend-insensitive optical glass
Diagram scale approx. 5:1
54
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Interconnect
Multimode and Singlemode
(UL) OFNP c(UL) FT6
FIBER COUNT
1
1
1
1
2
2
2
zip
CABLE
O.D. in.
mm
0.114
2.9
0.094
2.4
0.083
2.1
0.063
1.6
0.190
4.8
0.114
2.9
0.098
2.5
.113 x .235 2.9 x 6.0
MAXIMUM LOAD
INSTALL
lbs-f
96
96
48
48
128
96
96
128
N
427
427
213
213
569
427
427
569
CABLE WEIGHT
OPERATION
lbs-f
48
48
24
24
64
48
48
64
N
213
213
106
106
284
213
213
284
lbs/1000 ft kg/1000m
5.6
8.3
4.7
6.9
3.6
5.3
2.0
2.9
13.1
19.4
6.4
9.5
4.3
6.3
13.2
19.6
Indoor
Mechanical
Specifications
Interconnect (Plenum)
n Bend radius, no load = 10x cable overall diameter
n Bend radius, load = 15x cable overall diameter
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
Transmission
850nm
10GBASE-LR
1310nm
Serialized
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
55
SingleUnit
Product
Highlights
2 through 24 fibers
SingleUnit (Riser)
(UL) OFNR c(UL) FT4
n RoHS compliant
n 900µm buffered design recommended for easy termination.
n OM2, OM3 & OM4 cables utilize Corning ClearCurve glass
n Each fiber is color coded for easy identification
n Ideal intra-building cable solution
n Flexible and easy to handle
n Lightweight, flexible aramid
yarns enhance strength
Fiber Count
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
2
60514-2
60063-2
60463-2
61864-2
60012-2
61661-2
4
60515-4
60516-4
60520-4
61865-4
60014-4
61705-4
6
60515-6
60516-6
60520-6
61865-6
60014-6
61705-6
8
60515-8
60516-8
60520-8
61865-8
60014-8
61705-8
10
60515-10
60516-10
60520-10
61865-10
60014-10
61705-10
12
60515-12
60516-12
60520-12
61865-12
60014-12
61705-12
24
60515-24
60516-24
60520-24
61865-24
60014-24
61705-24
Options
n Cables with 600 micron buffer
available.
n Low smoke zero halogen available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit - other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
2-fiber
ISO/ IEC 11801, 2nd edition
6-fiber
Telcordia GR-409-CORE
1310 nm 1550 nm
OS2
0.50
0.50
OS2 BI**
0.50
0.50
**OS2 BI utilizes bend-insensitive optical glass
8-fiber
12-fiber
HCM reserves the right to revise any specifications.
Diagram scale approx. 2:1
56
I
HCM Fiber Max Attenuation Min Bandwidth Min Bandwidth* Gigabit Ethernet
10 Gigabit
Performance
Support Distance Ethernet Support
OFL
MHz-Km
MHz-Km
(dB/Km)
Parameters
(meters)
Distance (meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
4-fiber
10-fiber
I
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Multimode and Singlemode
SingleUnit
Mechanical
Specifications
(UL) OFNR c(UL) FT4
FIBER COUNT
CABLE
O.D. MAXIMUM LOAD
INSTALL
CABLE WEIGHT
n Bend radius, no load = 10x cable overall diameter
lbs/1000 ft kg/1000m
n Bend radius, load = 15x cable overall diameter
OPERATION
in.
mm
lbs-f
N
lbs-f
N
2
.190
4.8
128
569
64
284
11.5
17.1
4
.190
4.8
128
569
64
284
13.0
19.4
6
.190
4.8
128
569
64
284
14.5
21.6
8
.230
5.8
160
712
80
356
18.5
27.6
10
.230
5.8
160
712
80
356
20.0
29.8
12
.230
5.8
160
712
80
356
21.5
32.0
24
.350
8.8
288
1282
144
641
52.4
78.1
Indoor
SingleUnit (Riser)
10 Gigabit Applications
IEEE standard
Wavelength
Transmission
10GBASE-SR
850nm
Serialized
10GBASE-LR
1310nm
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
57
SingleUnit
Product
Highlights
2 through 24 fibers
SingleUnit (Plenum)
(UL) OFNP c(UL) FT6
n RoHS compliant
n 900µm buffered design recommended for easy termination.
Fiber Count
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n Each fiber is color coded for easy identification
n Ideal intra-building cable solution
n Flexible and easy to handle
n Lightweight, flexible aramid
yarns enhance strength
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
2
60024-2
60026-2
60471-2
61867-2
60031-2
61687-2
4
60517-4
60518-4
60522-4
61868-4
60029-4
61707-4
6
60517-6
60518-6
60522-6
61868-6
60029-6
61707-6
8
60517-8
60518-8
60522-8
61868-8
60029-8
61707-8
10
60517-10
60518-10
60522-10
61868-10
60029-10
61707-10
12
60517-12
60518-12
60522-12
61868-12
60029-12
61707-12
24
60517-24
60518-24
60522-24
61868-24
60029-24
61707-24
Options
n Cables with 600 micron buffer
available.
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit - other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
I
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
Gigabit Ethernet 10 Gigabit Ethernet
HCM Fiber
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
2-fiber
4-fiber
6-fiber
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
1310 nm 1550 nm
8-fiber
OS2
0.50
0.50
OS2 BI**
0.50
0.50
**OS2 BI utilizes bend-insensitive optical glass
10-fiber
12-fiber
HCM reserves the right to revise any specifications.
Diagram scale approx. 2:1
58
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Multimode and Singlemode
SingleUnit
Mechanical
Specifications
(UL) OFNP c(UL) FT6
FIBER COUNT
CABLE
O.D. MAXIMUM LOAD
INSTALL
CABLE WEIGHT
n Bend radius, no load = 10x cable overall diameter
lbs/1000 ft kg/1000m
n Bend radius, load = 15x cable overall diameter
OPERATION
in.
mm
lbs-f
N
lbs-f
N
2
.190
4.8
128
569
64
284
13.3
19.8
4
.190
4.8
128
569
64
284
14.5
21.6
6
.190
4.8
128
569
64
284
15.7
23.4
8
.230
5.8
160
712
80
356
20.9
31.1
10
.230
5.8
160
712
80
356
21.7
32.3
12
.230
5.8
160
712
80
356
23.0
34.3
24
.350
8.8
288
1282
144
641
52.4
78.1
Indoor
SingleUnit (Plenum)
10 Gigabit Applications
IEEE standard
Wavelength
Transmission
10GBASE-SR
850nm
Serialized
10GBASE-LR
1310nm
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
59
MultiUnit
Product
Highlights
12 through 144 fibers
MultiUnit (Riser)
(UL) OFNR c(UL) FT4
n RoHS compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n Each fiber is color coded for
easy identification
Fiber Count
# Fibers
per Tube
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
12
2
60369-12
60594-12
60585-12
61870-12
60621-12
24
2
60369-24
60594-24
60585-24
61870-24
60621-24
n Compact distribution design
24
4
60564-24
60588-24
60591-24
61871-24
60627-24
n Ideal intra-building, multi-floor
cable solution
48
4
60564-48
60588-48
60591-48
61871-48
60627-48
n Lightweight, flexible aramid
yarns enhance strength
18
6
60567-18
60595-18
60581-18
61872-18
60633-18
24
6
60567-24
60595-24
60581-24
61872-24
60633-4
36
6
60567-36
60595-36
60581-36
61872-36
60633-36
n Cables with a 600 micron buffer available
48
6
60567-48
60595-48
60581-48
61872-48
60633-48
72
6
60567-72
60595-72
60581-72
61872-72
60633-72
n Low smoke zero halogen available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit - other colors are available
n OM4 cables with extended
10 gigabit distances are
available
n OS2 Bend insensitive optical glass available
24
8
60569-24
60600-24
60603-24
61873-24
60638-24
32
8
60569-32
60600-32
60603-32
61873-32
60638-32
48
8
60569-48
60600-48
60603-48
61873-48
60638-48
72
8
60569-72
60600-72
60603-72
61873-72
60638-72
36
12
60006-36
60009-36
60613-36
61874-36
60015-36
48
12
60006-48
60009-48
60613-48
61874-48
60015-48
60
12
60006-60
60009-60
60613-60
61874-60
60015-60
72
12
60006-72
60009-72
60613-72
61874-72
60015-72
96
12
60006-96
60009-96
60613-96
61874-96
60015-96
144
12
60006-144
60009-144
60613-144
61874-144
60015-144
Options
Applications
n See Page 91
Optical Specifications
TIA/EIA- 568 -C.3
48-fibers (12 tubes of 4-fibers)
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
48-fibers (8 tubes of 6-fibers)
I
3.5
1.0
200
500
OM2
3.5
OM3
3.25
OM4
3.0
220
na
1.0
700
1.0
1500
1.0
3500
300
550
33
na
500
850
500
2000
na
750
550
150
na
na
1000
550
300
na
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
1310 nm 1550 nm
OS2
0.50
0.50
48-fibers (4 tubes of 12-fibers)
HCM reserves the right to revise any specifications.
Diagram scale approx. 1:1
60
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Multimode and Singlemode
MultiUnit
MultiUnit (Riser)
FIBER #Fibers
per
COUNT Tube Tube Layout
CABLE
MAXIMUM LOAD
O.D. INSTALL
OPERATION
in.
mm
lbs-f
N
lbs-f
N
3418
384
1709
CABLE WEIGHT
lbs/1000 ft kg/1000m
12
2
6xCSM
.630
16.0
768
131.0
195.2
24
2
9x3xCSM
.903
22.9
1536
6837
768
24
4
6xCSM
.630
16.0
768
3418
384
3418
249.0
371.0
1709
140.0
2086
48
4
9x3xCSM
.903
22.9
1536
6837
768
3418
263.0
391.9
18
6
3xCSM
.479
12.1
384
1709
192
854
77.0
114.7
24
6
4xCSM
.518
13.1
512
2279
256
1139
97.0
144.5
36
6
6xCSM
.630
16.0
768
3418
384
1709
148.0
220.5
48
6
8xCSM
.792
20.1
1024
4557
512
2279
253.0
377.0
72
6
9x3xCSM
.903
22.9
1536
6837
768
3418
280.0
417.2
24
8
3xCSM
.559
14.1
480
2136
240
1068
100.0
149.0
32
8
4xCSM
.614
15.5
640
3848
320
1424
127.0
189.2
48
8
6xCSM
.750
19.0
960
4273
480
2136
199.0
296.5
72
8
9xCSM
1.00
25.4
1440
6409
720
3204
393.0
585.6
36
12
3xCSM
.559
14.1
480
2136
240
1068
109.0
162.4
48
12
4xCSM
.614
15.5
640
2848
320
1424
139.0
207.1
60
12
5xCSM
.681
17.2
800
3561
400
1780
175.0
260.8
72
12
6xCSM
.750
19.0
960
4272
480
2136
216.0
321.8
96
12
8xCSM
.937
23.7
1280
5697
640
2848
360.0
536.4
144
12
9x3xCSM
1.06
26.9
1920
8545
960
4272
404.0
602.0
Indoor
Mechanical
Specifications
(UL) OFNR c(UL) FT4
n Bend radius, no load = 10x cable overall diameter
n Bend radius, load = 15x cable overall diameter
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
61
MultiUnit
Product
Highlights
12 through 144 fibers
MultiUnit (Plenum)
(UL) OFNP c(UL) FT6
n RoHS compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n Each fiber is color coded for
easy identification
Fiber Count
# Fibers per
Tube
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
12
2
60559-12
60582-12
60586-12
61875-12
60622-12
n Compact distribution design
24
2
60559-24
60582-24
60586-24
61875-24
60622-24
n Ideal intra-building, multi-floor
cable solution
24
4
60565-24
60589-24
60592-24
61876-24
60628-24
n Lightweight, flexible aramid
yarns enhance strength
Options
n Cables with a 600 micron buffer available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit - other colors are available
n OM4 cables with extended
10 gigabit distances are
available
48
4
60565-48
60589-48
60592-48
61876-48
60628-48
18
6
60258-18
60596-18
60598-18
61877-18
60634-18
24
6
60258-24
60596-24
60598-24
61877-24
60634-24
36
6
60258-36
60596-36
60598-36
61877-36
60634-36
48
6
60258-48
60596-48
60598-48
61877-48
60634-48
72
6
60258-72
60596-72
60598-72
61877-72
60634-72
24
8
60570-24
60601-24
60604-24
61878-24
60639-24
32
8
60570-32
60601-32
60604-32
61878-32
60639-32
48
8
60570-48
60601-48
60604-48
61878-48
60639-48
72
8
60570-72
60601-72
60604-72
61878-72
60639-72
36
12
60027-36
60028-36
60614-36
61879-36
60033-36
48
12
60027-48
60028-48
60614-48
61879-48
60033-48
Applications
60
12
60027-60
60028-60
60614-60
61879-60
60033-60
n See Page 91
72
12
60027-72
60028-72
60614-72
61879-72
60033-72
96
12
60027-96
60028-96
60614-96
61879-96
60033-96
144
12
60027-144
60028-144
60614-144
61879-144
60033-144
Optical Specifications
TIA/EIA- 568 -C.3
48-fibers (12 tubes of 4-fibers)
48-fibers (8 tubes of 6-fibers)
I
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
1310 nm 1550 nm
OS2
0.50
0.50
48-fibers (4 tubes of 12-fibers)
HCM reserves the right to revise any specifications.
Diagram scale approx. 1:1
62
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Multimode and Singlemode
MultiUnit
Mechanical
Specifications
(UL) OFNP c(UL) FT6
#Fibers
FIBER per
COUNT Tube
Tube
Layout
CABLE
MAXIMUM
O.D. LOAD INSTALL
in.
mm
OPERATION
lbs-f
N
lbs-f
N
CABLE WEIGHT
lbs/1000 ft kg/1000m
12
2
6xCSM
.630
16.0
768
3418
384
1709
131.0
195.2
24
2
9x3xCSM
.903
22.9
1536
6837
768
3418
249.0
371.0
24
4
6xCSM
.630
16.0
768
3418
384
1709
140.0
2086
48
4
9x3xCSM
.903
22.9
1536
6837
768
3418
263.0
391.9
18
6
3xCSM
.479
12.1
384
1709
192
854
77.0
114.7
24
6
4xCSM
.518
13.1
512
2279
256
1139
97.0
144.5
36
6
6xCSM
.630
16.0
768
3418
384
1709
148.0
220.5
48
6
8xCSM
.792
20.1
1024
4557
512
2279
253.0
377.0
72
6
9x3xCSM
.903
22.9
1536
6837
768
3418
280.0
417.2
24
8
3xCSM
.559
14.1
480
2136
240
1068
100.0
149.0
32
8
4xCSM
.614
15.5
640
3848
320
1424
127.0
189.2
48
8
6xCSM
.750
19.0
960
4273
480
2136
199.0
296.5
72
8
9xCSM
1.00
25.4
1440
6409
720
3204
393.0
585.6
36
12
3xCSM
.559
14.1
480
2136
240
1068
109.0
162.4
48
12
4xCSM
.614
15.5
640
2848
320
1424
139.0
207.1
60
12
5xCSM
.681
17.2
800
3561
400
1780
175.0
260.8
72
12
6xCSM
.750
19.0
960
4272
480
2136
216.0
321.8
96
12
8xCSM
.937
23.7
1280
5697
640
2848
360.0
536.4
144
12
9x3xCSM
1.06
26.9
1920
8545
960
4272
404.0
602.0
Indoor
MultiUnit (Plenum)
n Bend radius, no load = 10x cable overall diameter
n Bend radius, load = 15x cable overall diameter
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
63
NanoCore
12 and 24 fibers
™
Product
Highlights
NanoCore™ Loose Tube
No Gel Distribution Zip Cord (Plenum)
n RoHS compliant
(UL) OFNP c(UL) FT6
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n 250 micron loose tube design
allows for higher fiber strand
counts in a smaller overall diameter cable
Fiber Count
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
12
24
61546-12
61546-24
61539-12
61539-24
61882-12
61882-24
61547-12
61547-24
61713-12
61713-24
n Ideal for MT and MTP/MPO
style connectors
n No gel design makes installation quick, easy and clean
n Each fiber is color coded for
easy identification
n Flexible and easy to handle
n Lightweight, flexible Aramid
yarns enhance strength
Options
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit -other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
Zip Cord
I
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Max Attenuation Min Bandwidth Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
OFL MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.25
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
1310 nm 1550 nm
OS2
0.50
0.5
OS2 BI**
0.50
0.5
**OS2 BI utilizes bend-insensitive optical glass
HCM reserves the right to revise any specifications.
Diagram scale approx. 5:1
64
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Loose Tube
Multimode and Singlemode
Mechanical
Specifications
(UL) OFNP c(UL) FT6
n Bend radius, no load = 10x cable overall diameter
FIBER COUNT
12
24
CABLE
O.D. in.
mm
.118 x .255 3.0 x 6.47
.118 x .255 3.0 x 6.47
MAXIMUM LOAD
INSTALL
lbs-f
N
128
569
128
569
OPERATION
lbs-f
64
64
CABLE WEIGHT
N
284
284
lbs/1000 ft kg/1000m
11.3
16.8
11.4
17.0
Indoor
NanoCore™ Loose Tube
No Gel Distribution Zip Cord (Plenum)
n Bend radius, load = 15x cable overall diameter
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
850nm
10GBASE-LR
1310nm
Transmission
Serialized
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsPlenum
Overall Jacket
www.hcm.hitachi.com
Low-smoke, flame-retardant thermoplastic
Photo is for representation purposes only.
65
NanoCore
2 through 144 fibers
™
Product
Highlights
NanoCore™ Loose Tube
No Gel Distribution Single-Jacket (Plenum)
(UL) OFNP c(UL) FT6
n RoHS Compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n 250 micron loose tube design
allows for higher fiber strand
counts in a smaller overall diameter cable
Fiber Count
n Ideal for MT and MTP/MPO
style connectors
n No gel design makes installation quick, easy and clean
n Each fiber is color coded for
easy identification
n Flexible and easy to handle
n Lightweight, flexible Aramid
yarns enhance strength
Options
n Riser rated cables available
n OM1 cables available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit -other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Applications
50 UM
OM2
50 UM
OM3
8.3 UM
OS2
8.3 UM
OS2BI
2
2
61506-2
61507-2
61883-2
61538-2
61715-2
6
61506-6
61507-6
61883-6
61538-6
61715-6
8
8
61506-8
61507-8
61883-8
61538-8
61715-8
12
12
61506-12
61507-12
61883-12
61538-12
61715-12
24
24
61506-24
61507-24
61883-24
61538-24
61715-24
6
2
61732-6
61736-6
61889-6
61724-6
61778-6
18
6
61733-18
61737-18
61890-18
61725-18
61779-18
36
12
61734-35
61738-36
61890-36
61726-36
61780-36
72
24
61735-72
61739-72
61890-72
61727-72
61781-72
8
2
61732-8
61736-8
61889-8
61724-8
61778-8
24
6
61733-24
61737-24
61890-24
61725-24
61779-24
48
12
61734-48
61738-48
61890-48
61726-48
61780-48
96
24
61735-96
61739-96
61890-96
61727-96
61781-96
12
2
61732-12
61736-12
61889-12
61724-12
61778-12
36
6
61733-36
61737-36
61890-36
61725-36
61779-36
72
12
61734-72
61738-72
61890-72
61726-72
61780-72
144
24
61735-144
61739-144
61890-144
61727-144
61781-144
TIA/EIA- 568 -C.3
I
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
Gigabit Ethernet
10 Gigabit
Min Bandwidth* Support Distance Ethernet Support
MHz-Km
(meters)
Distance (meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
3.25**
1.0
200
500
220
na
300
550
33
na
3.25**
1.0
700
500
850
na
750
550
150
na
3.0**
1.0
1500
500
2000
na
1000
550
300
na
3.0
1.0
3500
500
4700
na
1100
550
550
na
for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
HCM
FIBER
OM1
OM2
OM3
OM4
*EMBc
50 UM
OM4
6
Optical Specifications
n See Page 91
12 fibers
# Fibers per
Tube
OS1
OS2
OS2 BI***
Max Attenuation Min Bandwidth
(dB/Km)
OFL MHz-Km
1310 nm 1550 nm
0.50
0.50
0.35
0.25
0.35
0.25
**OM1 & OM2 cables w/24 fibers/tube have max attenuation of 3.5dB/Km at 850 nm.
**OM3 cables w/24 fibers/tube have max attenuation of 3.25dB/Km at 850 nm.
***OS2 BI utilizes bend-insensitive optical glass
Diagram scale approx. 3:1
66
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Loose Tube
Multimode and Singlemode
(UL) OFNP c(UL) FT6
FIBER # Fibers Tube
COUNT perTube Layout
Tube
CABLE MAXIMUM OPERATION CABLE WEIGHT
O.D. O.D. LOAD INSTALL
in.
mm
in.
mm lbs-f
N
lbs-f N lbs/1000 ft kg/1000m
2
2
-
0.118
3.0
0.118
3.0
64
284
32
142
5.5
8.2
6
6
-
0.118
3.0
0.118
3.0
64
284
32
142
5.6
8.3
8
8
-
0.118
3.0
0.118
3.0
64
284
32
142
5.7
8.5
12
12
-
0.118
3.0
0.118
3.0
64
284
32
142
5.9
8.8
24
24
-
0.177
4.5
0.177
4.5
100
445
50
223
13.1
19.5
6
2
3xCSM 0.144 3.66 0.372 9.45
192
855
96
427
53.1
79
18
6
3xCSM 0.144 3.66 0.372 9.45
192
855
96
427
53.7
79.9
36
12
3xCSM 0.144 3.66 0.372 9.45
192
855
96
427
54.5
81.1
72
24
3xCSM 0.177
300
1335
150
668
69.6
103.6
4.5
0.443 11.25
8
2
4xCSM 0.144 3.66 0.428 10.87
256
1140
128
570
81.2
120.8
24
6
4xCSM 0.144 3.66 0.428 10.87
256
1140
128
570
81.9
121.8
48
12
4xCSM 0.144 3.66 0.428 10.87
256
1140
128
570
82.9
123.4
96
24
4xCSM 0.177
400
1780
200
890
105.4
156.9
4.5
0.507 12.88
12
2
6xCSM 0.144 3.66 0.512 13.00
384
1709
192
855
120.4
179.2
36
6
6xCSM 0.144 3.66 0.512 13.00
384
1709
192
855
121.5
180.8
72
12
6xCSM 0.144 3.66 0.512 13.00
384
1709
192
855
123.0
183
144
24
6xCSM 0.177
600
2670
300 1335
161.7
240.6
4.5
0.612 15.54
Mechanical
Specifications
Indoor
NanoCore™ Loose Tube
No Gel Distribution Single-Jacket (Plenum)
n Bend radius, no load = 10x cable overall diameter
n Bend radius, load = 15x cable overall diameter
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
850nm
Transmission
Serialized
10GBASE-LR
1310nm
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
Features
Dielectric MaterialsPlenum
Overall Jacket
www.hcm.hitachi.com
Low-smoke, flame-retardant thermoplastic
Photo is for representation purposes only.
67
NanoCore
12 through 96 fibers
™
Product
Highlights
NanoCore™Loose Tube
No Gel Distribution Dual-Jacket (Plenum)
n RoHS Compliant
(UL) OFNP c(UL) FT6
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n 250 micron loose tube design
allows for higher fiber strand
counts in a smaller overall diameter cable
Fiber Count
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
12
24
36
48
72
96
61549-12
61549-24
61549-36
61549-48
61549-72
61549-96
61509-12
61509-24
61509-36
61509-48
61509-72
61509-96
61884-12
61884-24
61884-36
61884-48
61884-72
61884-96
61550-12
61550-24
61550-36
61550-48
61550-72
61550-96
61717-12
61717-24
61717-36
61717-48
61717-72
61717-96
n Ideal for MT and MTP/MPO
style connectors
n No gel design makes installation quick, easy and clean
n Each fiber is color coded for
easy identification
n Color-coded binders separate
fiber strands into bundles of 12
n Rugged dual-jacket design
n Flexible and easy to handle
n Lightweight, flexible Aramid
yarns enhance strength
Options
n Cables with improved attenuation available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit -other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
10 Gigabit
Gigabit Ethernet
Min Bandwidth* Support Distance Ethernet Support
MHz-Km
(meters)
Distance (meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
3.5
1.0
200
500
220
na
300
550
33
na
3.5
1.0
700
500
850
na
750
550
150
na
3.25
1.0
1500
500
2000
na
1000
550
300
na
3.0
1.0
3500
500
4700
na
1100
550
550
na
for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
HCM
FIBER
OM1
OM2
OM3
OM4
*EMBc
I
Max Attenuation Min Bandwidth
(dB/Km)
OFL MHz-Km
1310 nm 1550 nm
OS2
0.5
0.5
OS2 BI**
0.5
0.5
**OS2 BI utilizes bend-insensitive optical glass
12-fibers
HCM reserves the right to revise any specifications.
Diagram scale approx. 3:1
68
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Loose Tube
Multimode and Singlemode
Mechanical
Specifications
(UL) OFNP c(UL) FT6
n Bend radius, no load = 10x cable overall diameter
FIBER 12-Fiber
COUNT Bundles
12
24
36
48
72
96
1
2
3
4
6
8
CABLE MAXIMUM
O.D. LOAD INSTALL
in.
mm
lbs-f
N
.335
8.5
384
1709
.335
8.5
384
1709
.335
8.5
384
1709
.335
8.5
384
1709
.335
8.5
384
1709
.335
8.5
384
1709
OPERATION
lbs-f
195
195
195
195
195
195
CABLE WEIGHT
N
855
855
855
855
855
855
lbs/1000 ft kg/1000m
47.0
70.0
47.2
70.3
47.4
70.6
47.6
70.9
47.8
71.2
60.3
79.7
Indoor
NanoCore™Loose Tube
No Gel Distribution Dual-Jacket (Plenum)
n Bend radius, load = 15x cable overall diameter
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
850nm
10GBASE-LR
1310nm
Transmission
Serialized
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsPlenum
Overall Jacket
www.hcm.hitachi.com
Low-smoke, flame-retardant thermoplastic
Photo is for representation purposes only.
69
Armored
Product
Highlights
2 through 24 fibers
Armored Tight Buffered (Riser)
(UL) OFCR c(UL) FT4
n RoHS compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n 900 um buffered design recommended for easy termination.
Fiber Count
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
2
60524-2
61542-2
61421-2
61896-2
61540-2
4
60524-4
61542-4
61421-4
61896-4
61540-4
6
60524-6
61542-6
61421-6
61896-6
61540-6
8
60524-8
61542-8
61421-8
61896-8
61540-8
10
60524-10
61542-10
61421-10
61896-10
61540-10
12
60524-12
61542-12
61421-12
61896-12
61540-12
24
60524-24
61542-24
61421-24
61896-24
61540-24
n Eliminates need for inner duct
or conduit
n Aluminum interlock armor
n Each fiber is color coded for easy identification
n Ideal intra-building cable solution
n Flexible and easy to handle
n Lightweight, flexible aramid
yarns enhance strength
Options
n Cables with up to 144 fibers
available
n Steel interlock available
n Low smoke zero halogen available
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit -other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
I
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
Gigabit Ethernet 10 Gigabit Ethernet
HCM Fiber
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
2-fiber
OM1
4-fiber
3.5
1.0
200
500
OM2
3.5
OM3
3.25
OM4
3.0
220
na
1.0
700
1.0
1500
1.0
3500
300
550
33
na
500
850
500
2000
na
750
550
150
na
na
1000
550
300
na
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
6-fiber
1310 nm 1550 nm
OS2
0.50
0.50
8-fiber
HCM reserves the right to revise any specifications.
10-fiber
12-fiber
Diagram scale approx. 2:1
70
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Armored
Multimode and Singlemode
Armored Tight Buffered (Riser)
Mechanical
Specifications
(UL) OFCR c(UL) FT4
FIBER COUNT
CABLE
MAXIMUM LOAD
O.D. INSTALL
OPERATION
CABLE WEIGHT
lbs-f
N
lbs-f
N
lbs/1000 ft
kg/1000m
2
.48
12.192
128
570
64
285
93.4
139.2
4
.48
12.192
128
570
64
285
94.9
141.4
6
.48
12.192
128
570
64
285
96.4
143.6
8
.52
13.208
160
712
80
356
109.9
163.8
10
.52
13.208
160
712
80
356
111.4
166.0
12
.52
13.208
160
712
80
356
112.9
168.2
24
.64
16.256
288
1282
144
641
164.1
244.5
n Bend radius, load = 20x cable overall diameter
Armored
mm
Indoor
in.
n Bend radius, no load = 15x cable overall diameter
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
Transmission
850nm
10GBASE-LR
1310nm
Serialized
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
71
Armored
Product
Highlights
2 through 24 fibers
Armored Tight Buffered (Plenum)
(UL) OFCP c(UL) FT6
n RoHS compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n 900um buffered design recommended for easy termination.
n Eliminates need for inner duct
or conduit
n Aluminum interlock armor
n Each fiber is color coded for easy identification
n Ideal intra-building cable solution
n Flexible and easy to handle
n Lightweight, flexible aramid
yarns enhance strength
Fiber
Count
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
2
60405-2
61319-2
61337-2
61897-2
61433-2
4
60405-4
61319-4
61337-4
61897-4
61433-4
6
60405-6
61319-6
61337-6
61897-6
61433-6
8
60405-8
61319-8
61337-8
61897-8
61433-8
10
60405-10
61319-10
61337-10
61897-10
61433-10
12
60405-12
61319-12
61337-12
61897-12
61433-12
24
60405-24
61319-24
61337-24
61897-24
61433-24
Options
n Standard colors are yellow for singlemode, orange for
multimode and aqua for 10 Gigabit -other colors are available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
2-fiber
I
ISO/ IEC 11801, 2nd edition
I
Telcordia GR-409-CORE
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
4-fiber
6-fiber
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
1310 nm 1550 nm
8-fiber
OS2
0.50
0.50
HCM reserves the right to revise any specifications.
10-fiber
12-fiber
Diagram scale approx. 2:1
72
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Armored
Multimode and Singlemode
Armored Tight Buffered (Plenum)
Mechanical
Specifications
(UL) OFCP c(UL) FT6
FIBER COUNT
CABLE
O.D. MAXIMUM LOAD
INSTALL
OPERATION
CABLE WEIGHT
mm
lbs-f
N
lbs-f
N
lbs/1000 ft
kg/1000m
2
.48
12.192
128
570
64
285
99.2
147.8
4
.48
12.192
128
570
64
285
100.4
149.6
6
.48
12.192
128
570
64
285
101.6
151.4
.52
13.208
160
712
80
356
116.7
173.9
.52
13.208
160
712
80
356
117.5
175.1
12
.52
13.208
160
712
80
356
118.8
177.0
24
.64
16.256
288
1282
144
641
164.1
244.5
Armored
8
10
n Bend radius, load = 20x cable overall diameter
Indoor
in.
n Bend radius, no load = 15x cable overall diameter
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
Transmission
850nm
10GBASE-LR
1310nm
Serialized
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
73
Tight Buffered
2 through 72 fibers
Product
Highlights
n RoHS compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n UV resistant jacket
n Tight buffered construction
I/O Tight Buffered (Riser)
(UL) OFNR c(UL) FT4
Fiber
Count
n Each fiber is color coded for
easy identification
n Dry, super absorbent polymers (SAPs) eliminate
water migration in cable interstices
n Suitable for lashed aerial, duct, underground conduit and indoor riser applications
n 900 um buffered design recommended for easy termination
#Fibers
per
Tube
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
2
2
61345-2
61347-2
61348-2
61893-2
61349-2
61719-2
4
4
61345-4
61347-4
61348-4
61893-4
61349-4
61719-4
6
6
61345-6
61347-6
61348-6
61893-6
61349-6
61719-6
8
8
61345-8
61347-8
61348-8
61893-8
61349-8
61719-8
10
10
61345-10
61347-10
61348-10
61893-10
61349-10
61719-10
12
12
61345-12
61347-12
61348-12
61893-12
61349-12
61719-12
24
24
61345-24
61347-24
61348-24
61893-24
61349-24
61719-24
36
6
61380-36
61376-36
61523-36
61898-36
61415-36
na
48
12
61495-48
61522-48
61524-48
61899-48
61363-48
na
72
12
61495-72
61522-72
61524-72
61899-72
61363-72
na
Options
n Low smoke zero halogen available
n OM4 cables with extended
10 gigabit distances are
available
6-fiber
Optical Specifications
TIA/EIA- 568 -C.3
12-fiber
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
48-fibers (4 tubes of 12-fibers)
1310 nm 1550 nm
OS2
0.50
0.50
OS2 BI**
0.50
0.50
**OS2 BI utilizes bend-insensitive optical glass
HCM reserves the right to revise any specifications.
Diagram scale approx. 2:1
74
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Tight Buffered
Multimode and Singlemode
I/O Tight Buffered (Riser)
Mechanical
Specifications
(UL) OFNR c(UL) FT4
FIBER #Fibers Tube
COUNT per Tube Layout
CABLE
MAXIMUM LOAD
O.D. INSTALL
OPERATION
in.
mm
lbs-f
N
lbs-f
N
CABLE WEIGHT
lbs/1000 ft kg/1000m
2
2
x
.190
4.8
128
570
64
285
12.6
18.8
4
4
x
.190
4.8
128
570
64
285
13.9
20.7
6
6
x
.190
4.8
128
570
64
285
15.1
22.5
8
8
x
.230
5.8
160
712
80
356
20.0
29.8
10
10
x
.230
5.8
160
712
80
356
21.3
31.7
12
12
x
.230
5.8
160
712
80
356
22.5
33.5
24
24
x
.350
8.8
288
1282
144
641
52.4
78.1
6
6xCSM
.657
16.7
600
2671
200
890
135.0
201.2
48
12
4xCSM
.64
16.4
600
2671
200
890
145.0
216.1
72
12
6xCSM
.816
20.7
600
2671
200
890
156.7
233.5
n Bend radius, load = 20x cable overall diameter
Tight Buffered
Indoor/Outdoor
36
n Bend radius, no load = 10x cable overall diameter
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
Transmission
850nm
Serialized
10GBASE-LR
1310nm
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
75
Tight Buffered
2 through 144 fibers
Product
Highlights
n RoHS compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n UV resistant jacket
n Tight buffered construction
I/O Tight Buffered (Plenum)
(UL) OFNP c(UL) FT6
Fiber Fibers per 62.5 UM
Count
tube
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
2
2
61460-2
61464-2
61468-2
61894-2
61459-2
61721-2
4
4
61460-4
61464-4
61468-4
61894-4
61459-4
61721-4
n Easy to strip and terminate
6
6
61460-6
61464-6
61468-6
61894-6
61459-6
61721-6
n Each fiber is color coded for easy identification
8
8
61460-8
61464-8
61468-8
61894-8
61459-8
61721-8
10
10
61460-10
61464-10
61468-10
61894-10
61459-10
61721-10
12
12
61460-12
61464-12
61468-12
61894-12
61459-12
61721-12
24
24
61460-24
61464-24
61468-24
61894-24
61459-24
61721-24
48
12
61979-48
61956-48
61959-48
61980-48
61480-48
61981-48
72
12
61979-72
61956-72
61959-72
61980-72
61480-72
61981-72
144
12
61979-144 61956-144
61959-144
61980-144
61480-144
61981-144
n Dry, super absorbent polymers
(SAPs) eliminate water migration in cable interstices
n Suitable for lashed aerial,
duct, underground conduit and
indoor plenum applications
n 900 um buffered design recommended for easy termination
Options
n OM4 cables with extended
10 gigabit distances are
available
6-fiber
Optical Specifications
TIA/EIA- 568 -C.3
12-fiber
Gigabit Ethernet 10 Gigabit Ethernet
HCM Fiber
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.5
1.0
200
500
220
na
300
550
33
na
OM2
3.5
1.0
700
500
850
na
750
550
150
na
OM3
3.25
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
1310 nm 1550 nm
48-fibers (4 tubes of 12-fibers)
OS2
0.50
0.50
OS2 BI**
0.50
0.50
**OS2 BI utilizes bend-insensitive optical glass
Diagram scale approx. 3:1
76
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Tight Buffered
Multimode and Singlemode
I/O Tight Buffered (Plenum)
Mechanical
Specifications
(UL) OFNP c(UL) FT6
FIBER # Fibers
COUNT per Tube
Tube
Layout
CABLE
MAXIMUM LOAD OPERATION
O.D. INSTALL
CABLE WEIGHT
n Bend radius, no load = 10x cable overall diameter
lbs/1000 ft kg/1000m
n Bend radius, load = 20x cable overall diameter
mm
lbs-f
N
lbs-f
N
2
x
.190
4.8
128
570
64
285
12.6
18.8
4
4
x
.190
4.8
128
570
64
285
13.9
20.7
6
6
x
.190
4.8
128
570
64
285
15.1
22.5
8
8
x
.230
5.8
160
712
80
356
20.0
29.8
10
10
x
.230
5.8
160
712
80
356
21.3
31.7
12
12
x
.230
5.8
160
712
80
356
22.5
33.5
24
24
x
.350
8.8
288
1282
144
641
52.4
78.1
48
12
4xCSM
0.627
15.9
640
2849
320
1424
135.1
201.1
72
12
6xCSM
0.756
19.2
960
4273
480
2136
226.6
337.2
144
12
9x3xCSM 1.072
27.2
1920
8546
960
4273
396.8
590.5
Tight Buffered
Indoor/Outdoor
in.
2
10 Gigabit Applications
IEEE standard
Wavelength
10GBASE-SR
850nm
10GBASE-LR
1310nm
Transmission
Serialized
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
77
Central Tube
Product
Highlights
n RoHS compliant
n OM2, OM3, & OM4 cables utilize Corning ClearCurve glass.
n UV resistant jacket
n Gel filled central tube provides protection against
water penetration
2 through 12 fibers
Indoor/Outdoor Central Tube (Riser)
(UL) OFNR c(UL) FT4
Fiber
Count
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
8.3 UM
OS2BI
2
60103-2
60104-2
60337-2
61837-2
60105-2
61723-2
4
60103-4
60104-4
60337-4
61837-4
60105-4
61723-4
6
60103-6
60104-6
60337-6
61837-6
60105-6
61723-6
n Dry, super absorbent polymers
(SAPs) eliminate water migration in cable interstices
8
60103-8
60104-8
60337-8
61837-8
60105-8
61723-8
10
60103-10
60104-10
60337-10
61837-10
60105-10
61723-10
12
60103-12
60104-12
60337-12
61837-12
60105-12
61723-12
n Suitable for lashed aerial, duct, underground conduit and indoor riser applications
Options
n Low smoke zero halogen available
n OM4 cables with extended
10 gigabit distances are
available
2-fibers
4-fibers
Optical Specifications
TIA/EIA- 568 -C.3-1
6-fibers
8-fibers
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.25
1.0
200
500
OM2
3.25
OM3
3.0
OM4
3.0
220
na
1.0
700
1.0
1500
1.0
3500
300
550
33
na
500
850
500
2000
na
750
550
150
na
na
1000
550
300
na
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
10-fibers
1310 nm 1550 nm
OS2
0.35
0.25
OS2 BI**
0.35
0.25
**OS2 BI utilizes bend-insensitive optical glass
12-fibers
HCM reserves the right to revise any specifications.
Diagram scale approx. 3:1
78
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Central Tube
Multimode and Singlemode
Indoor/Outdoor Central Tube (Riser)
Mechanical
Specifications
(UL) OFNR c(UL) FT4
FIBER COUNT
CABLE
O.D. MAXIMUM LOAD INSTALL
OPERATION
CABLE WEIGHT
Bend radius
in.
mm
lbs-f
N
lbs-f
N
lbs/1000 ft
kg/1000m
2
.287
7.2
300
1335
150
667
39.4
58.7
4
.287
7.2
300
1335
150
667
39.4
58.7
6
.287
7.2
300
1335
150
667
39.4
58.7
8
.287
7.2
300
1335
150
667
39.5
58.8
Central Tube Diameter
10
.287
7.2
300
1335
150
667
39.5
58.8
58.8
2-12 fibers per tube.160
12
.287
7.2
300
1335
150
667
39.6
n No load = 10x cable overall diameter
n Load = 20x cable overall diameter
in.
mm
4.1
10 Gigabit Applications
IEEE standard
Wavelength
850nm
Serialized
10GBASE-LR
1310nm
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
Indoor/Outdoor
10GBASE-SR
Transmission
For complete application list, refer to page 91.
Features
Dielectric MaterialsRiser
Overall Jacket
www.hcm.hitachi.com
Flame-retardant thermoplastic
Photo is for representation purposes only.
79
Loose Tube
12 through 144 fibers
1-fiber, 2-fiber and zip
Product
Highlights
n R
900
oHSmm
compliant
buffered design recommended
termination
n OM2,
OM3, & for
OM4
cables ST and
SC connectors
toutilize
Corning
ClearCurve n 6glass.
00 mm buffered design n U
optimized
V resistant
for jacket
termination and other
n to
Gel MT-RJ
filled loose
tubes small
provide
form factoragainst
connectors;
protection
water manufacturer for consult
penetration
recommended overall diameter
n Dry, super absorbent Ideal for patch
n polymers
(SAPs)cords,
eliminate
interconnections,
water
migration inandcable
short runs
interstices
n to strip
and terminate
uitable
for lashed
aerial, n ESasy
underground
duct,
n Lightweight, flexibleconduit
aramid and
riserstrength
applications
yarnsindoor
enhance
n Extremely flexible for easy handling
Options
n O
Mther
ost commonly
specified
diamn configurations
and fiber
eters
countshighlighted
available in tables
n LCow
ablessmoke
with zero
improved
halogen
attenuation available available
requestwith extended
upon
n O
M4 cables
10 gigabit distances are
available
Applications
n See Page 91
Indoor/Outdoor
Loose
Tube (Riser)
Interconnect
Cable
62.5/125
µm Multimode (Riser) (UL)
(UL) OFNR c(UL) FT4
OFNR c(UL) FT4
HITACHI
FIBER
# Fibers
Fiber
PART
NO.Count COUNT
in. Tube
perCABLE62.5 UM
O.D.
mm OM1
in
UM
CABLE
UM LOAD50
50MAXIMUM
50 UM
INSTALL OPERATIONWEIGHT
OM2
OM3
OM4
mm
in
mm
lbs/1000
12
2
60701-12
60710-12
60714-12
62.5/125 mm Multimode (62.5/125/250/900)
24
60710-24
60714-24
60001-1
1 2 .114 60701-24
2.9
TBD TBD
TBD
1
60037-1
24
60038-1
1
60425-1
1
48
60514-2
2
18
2
60001-2
60037-2
2
24
60005-2
zip
36
4
4
6
6
6
8
8
8
8
60720-12
60720-24TBD
TBD
TBD
TBD
60721-24TBD
TBD
TBD
60721-48TBD
TBD
TBD
60110-18TBD
TBD
TBD
60110-24TBD
TBD
TBD
.094
2.4
TBD
60344-24
60711-24
.083
2.1
TBD
.063 60344-48
1.6
TBD
60711-48
.190
4.8
TBD
60108-18
.114 60106-18
2.9
TBD
.094 60106-24
2.4
TBD
60108-24
.113
2.9 x 6.1 TBD
60108-36
x.240 60106-36
TBD TBD
60715-24
TBD TBD
TBD
TBD
60715-48
TBD TBD
60716-18
TBD
TBD
TBD
TBD
60716-24
TBD TBD
.114
2.9
TBD
60108-72
.094 60106-72
2.4
TBD
.083 60702-24
2.1
TBD
60712-24
.063
1.6
TBD
60712-32
.190 60702-32
4.8
TBD
.114
2.9
TBD
60702-48
60712-48
.094
2.4
TBD
.113 60702-72
2.9 x 6.1 60712-72
TBD
x.240
TBD TBD
60716-72
TBD
TBD
TBD
TBD
60717-24
TBD TBD
60717-32
TBD
TBD
TBD TBD
60717-48
TBD TBD
TBD
TBD
60717-72
TBD
61902-72
TBD
TBD
61903-24
TBD
61903-32
TBD
TBD
61903-48
TBD
TBD
61903-72
.094
2.4
TBD
60109-60
.083 60107-60
2.1
TBD
.063 60107-72
1.6
TBD
60109-72
.190
4.8
TBD
.114
2.9
TBD
.094
2.4
TBD
.113
2.9 x 6.1 TBD
x.240
TBD TBD
60719-60
TBD
TBD
TBD
TBD
60719-72
TBD TBD
TBD TBD
TBD TBD
TBD TBD
61902-36
61902-48
60110-36
60110-48
TBD
TBD
60110-72TBD
TBD
TBD
60722-24TBD
TBD
TBD
60722-32TBD
TBD
TBD
TBD
60722-48TBD
TBD
TBD
60722-72TBD
36
12
60107-36
60109-36
60719-36
61904-36
60111-36
62.5/125 mm Multimode (62.5/125/250/600) *Special Applications
60409-1
1 12 .114 60107-48
2.9
TBD TBD
TBD TBD
48
60109-48
60719-48
61904-48 TBD
60111-48TBD
60410-1
1
60
1 12
60411-1
60412-1
1 12
72
60508-2
2
2
60409-2
60410-2
2
60493-2
zip
62.5/125 mm StratusClear Multimode (62.5/125/250/600)
60413-1
1
.114
60414-1
1
.094
60415-1
1
.083
60416-1
1
.063
60511-2568 -C.3
2
.190
TIA/EIA60421-2
2
.114
HCM
Fiber
60422-2
2
.094
Min
60495-2 Max
zipAttenuation .113
Performance
(dB/Km) x.240
Parameters
2.9
2.4
2.1
1.6
4.8
2.9
2.4
Bandwidth
OFL
2.9 x 6.1
Optical Specifications
48-fibers (12 tubes of 4-fibers)
1-fiber Interconnect
61900-12
61900-24
TBD
TBD
61901-24
TBD
TBD
61901-48
TBD
61902-18
TBD
TBD
61902-24
TBD
6
60716-36
62.5/125
mm
StratusClear
Multimode
(62.5/125/250/900)
48
6
60106-48
60108-48
60716-48
60426-1
1
72
60427-1
1
1
60428-1
24
60429-1
1
32
60326-2
2
2
60426-2
48
60426-2
2
60324-2
zip
72
8.3 UM
OS2 kg/1000m
MHz-Km
TBD
61904-60
TBD
TBD
61904-72
TBD
TBD
TBD
TBD
TBD
TBD
60111-60TBD
TBD
TBD
60111-72TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
*Special Applications
TBD TBD TBD TBD
TBD
TBD
TBD TBD TBD TBD
TBD
TBD
TBD TBD TBD TBD
TBD
TBD
TBD TBD TBD TBD
TBD
TBD
TBD TBD TBD TBD
TBD
TBD
TBD TBD TBD TBD
TBD
TBD
Ethernet 10
Gigabit Ethernet
TBD TBD TBDGigabit
TBD
TBD
TBD
Min Bandwidth* TBD
TBD TBD
TBD
TBD
Support
Distance TBD
Support Distance
MHz-Km
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
48-fibers (8 tubes of 6-fibers)
3.25
48-fibers (6 tubes of 8-fibers)
OM4
3.0
I
MAXIMUM ATTENTUATION
na
300
550
33
na
850
na
750
550
150
na
na
1000
550
300
Bellcore
GR-409-CORE
na
1.0
1500
2000
ISO/ IEC
11801, 500
2nd edition
1.0
3500
500
62.5/125 m
µ Multimode
4700
< 3.0 dB/km at 850 nm
< 0.7 dB/km at 1300 nm
1310 nm 1550 nm
I
na
1100
550
StratusClear 62.5/125 m
µ
na
< 3.0 dB/km at 850 nm
< 0.7 dB/km at 1300 nm
200 MHz•km at 850 nm
500 MHz•km at 1300 nm
200 MHz•km at 850 nm
500 MHz•km at 1300 nm
Minimum Bandwidth
(RML)
220 MHz•km at 850 nm
n/s
385 MHz•km at 850 nm
n/s
300 m at 850 nm
500 m at 850 nm
HITACHI CABLE MANCHESTER, INC.
550
MULTIMODE
Minimum Bandwidth
0.35(OFL) 0.25
Gigabit Ethernet Support
80
220
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
OS2
Diagram scale
scale approx.
approx. 3:1
Diagram
1:1
500
1.0
700
500
Optical3.25Specifications
Zip of
Cord
48-fibers2-fiber
(4 tubes
12-fibers)
200
OM2
OM3
TIA/EIA- 5683.0
-B.3
2-fiber Interconnect
1.0
HCM reserves the right to revise any specifications.
1.800.772.0116
Interconnect
Loose Tube
Multimode and Singlemode
62.5/125 µm Multimode
(UL)
(UL)OFNR
OFNP c(UL)
c(UL)FT4
FT6
FIBER #Fibers
per FIBER
Tube
COUNT
HITACHI
PART NO.
COUNT
in.
Tube
Layout
CABLE
O.D.
mm
CABLE
O.D. in.in mm
MAXIMUM LOAD
INSTALL
MAXIMUM
LOAD INSTALL lbs-f in
mm
12
2
6xCSM
.422 10.7
600
62.5/125 mm Multimode (62.5/125/250/900)
24
21
12xCSM
600
60042-1
.114 .595
2.9 15.1 TBD
60430-1
24
60431-1
60432-1
48
60024-2
18
60042-2
60430-2
24
60023-2
1
41
41
2
62
62
zip
.094
6xCSM
.083
.063
12xCSM
.190
6xCSM
.114
.094
6xCSM
2.4
.422
2.1
1.6
.595
4.8
.422
2.9
2.4
.422
10.7
15.1
10.7
10.7
.113 x.2352.9 x 6.0
N
OPERATION
CABLE OPERATIONWEIGHT
N
mm lbs-flbs/1000
2670
200
TBD
600
TBD
TBD
600
TBD
600
TBD
TBD
600
TBD
TBD
TBD
600
TBD
600
TBD
TBD
600
TBD
600
TBD
TBD
TBD TBD TBD
TBD
2670 TBD200TBD890
TBD TBD TBD
2670 TBD200TBD890
TBD
TBD
2670 TBD200TBD890
TBD TBD TBD
2670 TBD200TBD890
TBD
TBD TBD TBD
36
6
6xCSM
.422 10.7
600
2670
200
62.5/125
mm
StratusClear
Multimode
(62.5/125/250/900)
48
6
8XCSM .482 12.2
600
2670
200
60433-1
60434-1
72
60435-1
24
60436-1
60332-2
32
60433-2
48
60434-2
60330-2
1
.114
2.9
.083
2.1
61
.094 .595
2.4 15.1
12XCSM
81
6xCSM
.063 .422
1.6 10.7
2
82
zip
6xCSM
.094 .422
2.4 10.7
1
82
.190 .422
4.8 10.7
6xCSM
.114
2.9
.113 x.2352.9 x 6.0
72
8
9XCSM
.509 12.9
600
62.5/125 mm Multimode (62.5/125/250/600)
36
12
6xCSM
.466
11.8
600
60417-1
1
.114
2.9
TBD
121
1
121
122
2
2
zip
.094 .422
2.4 11.8
6xCSM
.083
2.1
6xCSM
.063 .466
1.6 11.8
.190 .466
4.8 11.8
6xCSM
.114
2.9
.094
2.4
.113 x.2352.9 x 6.0
2670
200
*Special Applications
TBD
600
TBD
600
TBD
TBD
600
TBD
TBD
TBD
1
1
1
1
2
2
2
zip
Features
.114
.094
.083
.063
.190
.114
.094
2.9
2.4
2.1
1.6
4.8
2.9
2.4
.113 x.2352.9 x 6.0
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
890
890
2670 TBD200TBD890
TBD
TBD
2670 TBD200TBD890
TBD TBD TBD
2670 TBD200TBD890
TBD
TBD
2670 TBD200TBD890
TBD TBD TBD
TBD TBD TBD
TBD TBD TBD
62.5/125 mm StratusClear Multimode (62.5/125/250/600)
60421-1
60422-1
60423-1
60424-1
60024-2
60042-2
60430-2
60496-2
890
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
231.0
Loose Tube Diameter
77.0
114.7
155
TBD
231.0
TBD
TBD
78.0
TBD
TBD
155
TBD
64
TBD
TBD
69.0
TBD
78.0
116.2
TBD
TBD
95.4
TBD
TBD
102.8
TBD
116.2
100
149.0
TBD
156
TBD
232.4
113
168.4
TBD
TBD
64
TBD
TBD
69.0
TBD
78.0
TBD
TBD
73.0
TBD
TBD
79.0
TBD
85.0
TBD
TBD
91.0
TBD
TBD
TBD
*Special Applications
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
lbs/1000
kg/1000mft kg/1000m
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
in.
mm
2-8 fibers per tube.095
2.4
12-fibers per tube .110
2.8
TBD
TBD
95.4
TBD
TBD
102.8
TBD
117.7
TBD
TBD
108.8
TBD
TBD
117.7
TBD
126.7
TBD
TBD
135.6
TBD
TBD
TBD
Indoor/Outdoor
60418-1
48
60419-1
60
60420-1
60024-2
72
60042-2
60430-2
60494-2
890
2670 TBD200TBD890
TBD
TBD TBD TBD
2670 TBD200TBD890
TBD
TBD
2670 TBD200TBD890
TBD TBD TBD
2670 TBD200TBD890
TBD
TBD
2670 TBD200TBD890
TBD TBD TBD
n Bend radius, no load Bend
radius
= 4x
cable overall diameter
o
load
= 10x
n N
Bend radius,
loadcable
diameter
=overall
10x cable
overall diameter
n Load = 20x cable overall diameter
CABLE WEIGHT
Mechanical
Specifications
Indoor
Indoor/Outdoor
Interconnect Cable
Loose
62.5/125
Tube (Riser)
µm Multimode (Plenum)
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
Features
Dielectric Dielectric
MaterialsRiser
MaterialsRiser
Plenum
Overall Jacket
Low-smoke, flame-retardant thermoplastic
www.hcm.hitachi.com
thermoplastic
Flame-retardant thermoplastic
Photo is for representation purposes only.
81
Mojave
12 through 432 fibers
™
Product
Highlights
Mojave™ Dry-Block Outdoor (Outside Plant) Loose Tube
n RoHS compliant
n UV resistant jacket
Fiber Count
n Dry, super absorbent polymers
(SAPs) eliminate water migration in cable interstices
and loose tubes
12
2
61963-12
61967-12
61971-12
61975-12
61952-12
24
2
61963-24
61967-24
61971-24
61975-24
61952-24
n Suitable for lashed aerial, duct, and underground conduit
applications
n Dual jacket constructions available
Options
n Other configurations and fiber
counts available
n Corrugated steel armor available
n Dual jacket constructions available
n Low smoke zero halogen available
n Up to 432 fibers available
n OM4 cables with extended
10 gigabit distances are
available
Applications
n See Page 91
48-fibers (12 tubes of 4-fibers)
# Fibers per
Tube
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
24
4
61964-24
61968-24
61972-24
61976-24
61953-24
48
4
61964-48
61968-48
61972-48
61976-48
61953-48
18
6
61965-18
61969-18
61973-18
61977-18
61954-18
24
6
61965-24
61969-24
61973-24
61977-24
61954-24
36
6
61965-36
61969-36
61973-36
61977-36
61954-36
48
6
61965-48
61969-48
61973-48
61977-48
61954-48
12
12
61966-12
61970-12
61974-12
61978-12
61955-12
24
12
61966-24
61970-24
61974-24
61978-24
61955-24
36
12
61966-36
61970-36
61974-36
61978-36
61955-36
48
12
61966-48
61970-48
61974-48
61978-48
61955-48
60
12
61966-60
61970-60
61974-60
61978-60
61955-60
72
12
61966-72
61970-72
61974-72
61978-72
61955-72
84
12
61966-84
61970-84
61974-84
61978-84
61955-84
96
12
61966-96
61970-96
61974-96
61978-96
61955-96
108
12
61966-108
61970-108
61974-108
61978-108
61955-108
120
12
61966-120
61970-120
61974-120
61978-120
61955-120
132
12
61966-132
61970-132
61974-132
61978-132
61955-132
144
12
61966-144
61970-144
61974-144
61978-144
61955-144
168
12
61966-168
61970-168
61974-168
61978-168
61955-168
192
12
61966-192
61970-192
61974-192
61978-192
61955-192
216
12
61966-216
61970-216
61974-216
61978-216
61955-216
240
12
61966-240
61970-240
61974-240
61978-240
61955-240
264
12
61966-264
61970-264
61974-264
61978-264
61955-264
Optical Specifications
TIA/EIA- 568 -C.3
48-fibers (8 tubes of 6-fibers)
48-fibers (4 tubes of 12-fibers)
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Attenuation Min Bandwidth OFL Min Bandwidth* Support
Performance Max(dB/Km)
Distance Support Distance
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.25
1.0
200
500
220
na
300
550
33
na
OM2
3.25
1.0
700
500
850
na
750
550
150
na
OM3
3.0
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
1310 nm 1550 nm
432-fibers (36 tubes of 12-fibers)
OS2
0.35
0.25
Diagram scale approx. 1:1
82
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.890.772.0116
Multimode and Singlemode
Loose Tube
Mojave™ Dry-Block Outdoor (Outside Plant) Loose Tube
# Fibers
FIBER per
COUNT
Tube
CABLE
O.D. Tube Layout
MAXIMUM LOAD
INSTALL
OPERATION
CABLE
WEIGHT
Mechanical
Specifications
in.
mm
lbs-f
N
lbs-f
N
lbs/1000 ft
Bend radius
n No load = 10x cable overall diameter
12
2
6xCSM
.493
12.5
600
2670
200
890
63.8
24
2
12XCSM
.695
17.7
600
2670
200
890
139.6
24
4
6xCSM
.493
12.5
600
2670
200
890
64.8
48
4
12XCSM
.695
17.7
600
2670
200
890
139.6
18
6
5XCSM
.463
11.7
600
2670
200
890
50.9
Loose Tube Diameter
24
6
5XCSM
.463
11.7
600
2670
200
890
53.2
36
6
6xCSM
.493
12.5
600
2670
200
890
64.8
48
6
8XCSM
.561
14.2
600
2670
200
890
83.4
2-12 fibers
per tube
12
12
5XCSM
.463
11.7
600
2670
200
890
46.3
24
12
5XCSM
.463
11.7
600
2670
200
890
48.6
36
12
5XCSM
.463
11.7
600
2670
200
890
50.9
48
12
5XCSM
.463
11.7
600
2670
200
890
53.2
60
12
5XCSM
.463
11.7
600
2670
200
890
55.5
72
12
6xCSM
.493
12.5
600
2670
200
890
65.8
84
12
7XCSM
.552
14.0
600
2670
200
890
81.1
96
12
8XCSM
.581
14.8
600
2670
200
890
92.4
108
12
9XCSM
.611
15.5
600
2670
200
890
104.7
120
12
10XCSM
.649
16.5
600
2670
200
890
120
132
12
11XCSM
.683
17.3
600
2670
200
890
134.3
144
12
12XCSM
.715
18.2
600
2670
200
890
150.6
168
12
12X6XCSM
.737
18.7
600
2670
200
890
1406.2
192
12
12X6XCSM
.737
18.7
600
2670
200
890
123.8
216
12
12X6XCSM
.737
18.7
600
2670
200
890
128.4
240
12
13X7XCSM
.770
19.6
600
2670
200
890
141
264
12
14X8XCSM
.805
20.4
600
2670
200
890
158.6
n Load = 20x cable overall diameter
in.
mm
.110
2.8
Outdoor
Features
Dielectric Materials
Overall Jacket
www.hcm.hitachi.com
Medium density polyolefin
Photo is for representation purposes only.
83
Loose Tube
Product
Highlights
n RoHS compliant
n UV resistant jacket
12 through 432 fibers
Outdoor (Outside Plant)
Loose Tube
Fiber Count
# Fibers per
Tube
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
12
2
60351-12
60282-12
60938-12
61905-12
60950-12
24
2
60351-24
60282-24
60938-24
61905-24
60950-24
24
4
60235-24
60408-24
60939-24
61906-24
60951-24
48
4
60235-48
60408-48
60939-48
61906-48
60951-48
18
6
60085-18
60087-18
60940-18
61907-18
60089-18
24
6
60085-24
60087-24
60940-24
61907-24
60089-24
36
6
60085-36
60087-36
60940-36
61907-36
60089-36
48
6
60085-48
60087-48
60940-48
61907-48
60089-48
12
12
60086-12
60088-12
60943-12
61908-12
60090-12
24
12
60086-24
60088-24
60943-24
61908-24
60090-24
36
12
60086-36
60088-36
60943-36
61908-36
60090-36
48
12
60086-48
60088-48
60943-48
61908-48
60090-48
60
12
60086-60
60088-60
60943-60
61908-60
60090-60
72
12
60086-72
60088-72
60943-72
61908-72
60090-72
84
12
60086-84
60088-84
60943-84
61908-84
60090-84
96
12
60086-96
60088-96
60943-96
61908-96
60090-96
108
12
60086-108
60088-108
60943-108
61908-108
60090-108
120
12
60086-120
60088-120
60943-120
61908-120
60090-120
Applications
132
12
60086-132
60088-132
60943-132
61908-132
60090-132
144
12
60086-144
60088-144
60943-144
61908-144
60090-144
n See Page 91
168
12
60086-168
60088-168
60943-168
61908-168
60090-168
192
12
60086-192
60088-192
60943-192
61908-192
60090-192
216
12
60086-216
60088-216
60943-216
61908-216
60090-216
240
12
60086-240
60088-240
60943-240
61908-240
60090-240
264
12
60086-264
60088-264
60943-264
61908-264
60090-264
n Gel filled loose tubes provide
protection against water penetration
n Dry, super absorbent polymers
(SAPs) eliminate water migration in cable interstices
n Suitable for lashed aerial, duct, and underground conduit
applications
n SM Fiber is RDUP approved
Options
n Other configurations and fiber
counts available
n Dual jacket constructions available
n Low smoke zero halogen available
n Up to 432 fibers available
n OM4 cables with extended
10 gigabit distances are
available
48-fibers (12 tubes of 4-fibers)
Optical Specifications
TIA/EIA- 568 -C.3
48-fibers (8 tubes of 6-fibers)
48-fibers (4 tubes of 12-fibers)
I
RDUP 7CFR.1755
HCM Fiber
Gigabit Ethernet 10 Gigabit Ethernet
Attenuation Min Bandwidth OFL Min Bandwidth* Support
Performance Max(dB/Km)
Distance Support Distance
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
OM1
3.25
1.0
200
500
OM2
3.25
OM3
3.0
OM4
3.0
220
na
1.0
700
1.0
1500
1.0
3500
300
550
33
na
500
850
500
2000
na
750
550
150
na
na
1000
550
300
na
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
432-fibers (36 tubes of 12-fibers)
1310 nm 1550 nm
OS2
0.35
0.25
Diagram scale approx. 1:1
84
HCM reserves the right to revise any specifications.
HITACHI CABLE MANCHESTER, INC.
1.890.772.0116
Multimode and Singlemode
Loose Tube
Outdoor (Outside Plant) Loose Tube
#
FIBER Fibers
COUNT per Tube Layout
Tube
CABLE
O.D. MAXIMUM LOAD
INSTALL
OPERATION
CABLE WEIGHT
in.
mm
lbs-f
N
lbs-f
N
12
2
6xCSM
.493
12.5
600
2670
200
890
lbs/1000 ft kg/1000m
74.0
110.3
24
2
12XCSM
.700
17.8
600
2670
200
890
160.0
238.4
24
4
6xCSM
.493
12.5
600
2670
200
890
75.0
111.8
48
4
12XCSM
.700
17.8
600
2670
200
890
160.0
238.4
18
6
5XCSM
.463
11.7
600
2670
200
890
56.0
83.4
24
6
5XCSM
.463
11.7
600
2670
200
890
60.0
89.4
36
6
6xCSM
.493
12.5
600
2670
200
890
75.0
111.8
48
6
8XCSM
.561
14.2
600
2670
200
890
97.0
144.5
12
12
5XCSM
.463
11.7
600
2670
200
890
48.0
71.5
24
12
5XCSM
.463
11.7
600
2670
200
890
52.0
77.5
36
12
5XCSM
.463
11.7
600
2670
200
890
56.0
83.4
48
12
5XCSM
.463
11.7
600
2670
200
890
60.0
89.4
60
12
5XCSM
.463
11.7
600
2670
200
890
64.0
95.4
72
12
6xCSM
.493
12.5
600
2670
200
890
76.0
113.2
84
12
7XCSM
.552
14.0
600
2670
200
890
93.0
138.6
96
12
8XCSM
.581
14.8
600
2670
200
890
106.0
157.9
108
12
9XCSM
.620
15.7
600
2670
200
890
120.0
178.8
120
12
10XCSM
.649
16.5
600
2670
200
890
137.0
204.1
132
12
11XCSM
.683
17.3
600
2670
200
890
153.0
228.0
144
12
12XCSM
.720
18.3
600
2670
200
890
171.0
255.0
168
12
12X6XCSM
.737
18.7
600
2670
200
890
1430
213.1
192
12
12X6XCSM
.737
18.7
600
2670
200
890
151.0
225.0
216
12
12X6XCSM
.737
18.7
600
2670
200
890
159.0
236.9
240
12
13X7XCSM
.770
19.6
600
2670
200
890
175.0
260.8
264
12
14X8XCSM
.805
20.4
600
2670
200
890
196.0
292.0
Mechanical
Specifications
Bend radius
n No load = 10x cable overall diameter
n Load = 20x cable overall diameter
Loose Tube Diameter
in.
2-12 fibers per tube .110
mm
2.8
Outdoor
Features
Dielectric Materials
Overall Jacket
www.hcm.hitachi.com
Medium density polyolefin
Photo is for representation purposes only.
85
Loose Tube
Product
Highlights
n RoHS compliant
n Rugged corrugated steel armor
provides extra crush-resistance and rodent protection
12 through 144 fibers
Outdoor (Outside Plant)
Armored
Fiber Count
# Fibers per
Tube
62.5 UM
OM1
50 UM
OM2
50 UM
OM3
50 UM
OM4
8.3 UM
OS2
24
2
60346-24
60932-24
60944-24
61909-24
60954-24
n UV resistant jacket
n Gel filled loose tube provides protection against
water penetration
n Dry, super absorbent polymers (SAPs) eliminate
water migration in cable interstices
48
4
60345-48
60933-48
60945-48
61910-48
60356-48
48
6
60097-48
60934-48
60946-48
61911-48
60101-48
12
12
60098-12
60937-12
60949-12
61912-12
60102-12
24
12
60098-24
60937-24
60949-24
61912-24
60102-24
48
12
60098-48
60937-48
60949-48
61912-48
60102-48
144
12
60098-144
60937-144
60949-144
61912-144
60102-144
n Suitable for lashed aerial, duct, and underground conduit
applications
Options
n Other configurations and fiber
counts available
n Dual jacket constructions available
n Low smoke zero halogen available
n OM4 cables with extended
10 gigabit distances are
available
Optical Specifications
TIA/EIA- 568 -C.3
Gigabit Ethernet 10 Gigabit Ethernet
HCM Fiber
Max Attenuation Min Bandwidth OFL Min Bandwidth* Performance
Support Distance Support Distance
(dB/Km)
MHz-Km
MHz-Km
Parameters
(meters)
(meters)
850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm
48-fibers (12 tubes of 4-fibers)
OM1
3.25
1.0
200
500
220
na
300
550
33
na
OM2
3.25
1.0
700
500
850
na
750
550
150
na
OM3
3.0
1.0
1500
500
2000
na
1000
550
300
na
OM4
3.0
1.0
3500
500
4700
na
1100
550
550
na
*EMBc for OM2, OM3 & OM4 fibers. RML for OM1 fibers.
48-fibers (8 tubes of 6-fibers)
1310 nm 1550 nm
OS2
0.35
0.25
HCM reserves the right to revise any specifications.
48-fibers (4 tubes of 12-fibers)
Diagram scale approx. 1:1
86
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Loose Tube
Multimode and Singlemode
Armored
Outdoor (Outside Plant) Armored
FIBER #Fibers
Tube
COUNT per Tube Layout
MAXIMUM LOAD
CABLE
O.D. INSTALL
Mechanical
Specifications
CABLE WEIGHT
OPERATION
in.
mm
lbs-f
N
lbs-f
N
lbs/1000
ft
kg/1000m
24
2
12xCSM
0.748
19.0
600
2700
200
890
228.0
339.7
48
4
12xCSM
0.748
19.0
600
2700
200
890
229.0
341.2
48
6
8XCSM
0.613
15.6
600
2700
200
890
147.0
219.0
12
12
5XCSM
0.508
13.1
600
2700
200
890
97.0
144.5
24
12
5XCSM
0.508
13.1
600
2700
200
890
101.0
150.0
48
12
5XCSM
0.508
13.1
600
2700
200
890
110.0
163.9
144
12
12xCSM
0.768
19.5
600
2700
200
890
241.0
359.1
Bend radius
n No load = 10x cable overall diameter
n Load = 20x cable overall diameter
Loose Tube Diameter
in.
2-12 fibers per tube.110
mm
2.8
10 Gigabit Applications
IEEE standard
Wavelength
Transmission
10GBASE-SR
850nm
Serialized
10GBASE-LR
1310nm
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
Fiber type
Length (m)
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
For complete application list, refer to page 91.
Features
Armored
Outdoor
Dielectric Materials
Overall Jacket
www.hcm.hitachi.com
Medium density polyolefin
Photo is for representation purposes only.
87
Color Code
High Pair
Count Cables
When cables contain more
than one pair group, different
color binder tapes are used to
differentiate the 25 pair groups.
Primary
Insulation (FEP)
Color Coding
HCM uses a co-extruded FEP
color stripe to mark FEP insulated
conductors. This process provides
several benefits:
n Marking durability is insured
for the life of the cable
n Electrical characteristics of the
marking stripe match the FEP
insulation
n Avoids highly toxic ink
systems that are required to
bond to FEP
Pair #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Fiber #
1 2 3 4 5 6 7 8 9 10 11 12 Chart
Copper Conductor Color Combinations
White/Blue - Blue/White
White/Orange - Orange/White
White/Green - Green/White
White/Brown - Brown/White
White/Gray - Gray/White
Red/Blue - Blue/Red
Red/Orange - Orange/Red
Red/Green - Green/Red
Red/Brown - Brown/Red
Red/Gray - Gray/Red
Black/Blue - Blue/Black
Black/Orange - Orange/Black
Black/Green - Green/Black
Black/Brown - Brown/Black
Black/Gray - Gray/Black
Yellow/Blue - Blue/Yellow
Yellow/Orange - Orange/Yellow
Yellow/Green - Green/Yellow
Yellow/Brown - Brown/Yellow
Yellow/Gray - Gray/Yellow
Violet/Blue - Blue/Violet
Violet/Orange - Orange/Violet
Violet/Green - Green/Violet
Violet/Brown - Brown/Violet
Violet/Gray - Gray/Violet
Fiber Buffer Color
Blue
Orange
Green
Brown
Gray
White
Red
Black
Yellow
Violet
Pink
Aqua
Note:
To differentiate bundles in cables with greater than 12 strands, polyester binders or buffer tubes (depending on the
construction) are used. Those binders or buffer tubes will incorporate the same color code found in the chart above.
The color code is part of the TIA-598 standard. For indoor, multiunit fiber optic cables, subunits will be numbered
for identification.
88
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Code
References
National Electric Code
Code
References
Cable Substitution
Hierarchy
NEC and CSA
Fire Resistance
Levels
Fire Resistance Level
Test Requirement
NEC 725
NEC 760
NEC 800
(Highest) Plenum Cables
UL-910 (Steiner Tunnel)
CSA-FT6 (Steiner Tunnel)
CL3P
CL2P
FPLP
CMP
Riser Cables Multiple Floors
UL-1666 (Vertical Shaft)
CSA-FT4, CMG (Vertical Tray)
CL3R
CL2R
FPLR
CMR
General Purpose Cables
UL-1581 (Vertical Tray)
CSA-FT4, CMG (Vertical Tray)
CL3
CL2
FPL
CM
(Lowest) Residential Cables
Restricted Use
UL-1581 VW-1
CSA-FT1
CL3X
CL2X
CMX
Notes
1 C ables with a higher fire resistance level may be substituted for those with a lower fire resistance level, except that
FT6 must also be marked FT4 for FT4 applications.
2 C ables rated CM may be used in runs penetrating one floor. (NEC 800-53)
National Electric Code and NEC are registered trademarks of the National Fire Protection Association, Inc. Quincy, MA.
www.hcm.hitachi.com
89
Applications
Copper
Applications Support Matrix
Category 3
Category 5e Category 6
Category 6A Category 71
Voice
n
n
n
n
n
T1 Fractional
n
n
n
n
n
IBM Type 3 - 1 Mbps
n
n
n
n
n
4/16 Mbps Token Ring
n
n
n
n
n
10BASE-T Ethernet
n
n
n
n
n
100BASE-T4 Fast Ethernet
n
n
n
n
n
25.6 Mbps ATM
n
n
n
n
n
100 VG - Any LAN
n
n
n
n
n
All other applications
developed to operate over
Category 3 or class C cabling
n
n
n
n
n
100 Mbps TP-PMD
n
n
n
n
155 Mbps ATM
n
n
n
n
270 Mbps digital video
n
n
n
n
Broadband video
n
n
n
n
100BASE-TX Fast Ethernet
n
n
n
n
1000BASE-T Gigabit Ethernet
n
n
n
n
All other applications
developed to operate over
Category 5e or class D cabling
n
n
n
n
1000 Mbps ATM (CBIG)
n
n
n
All other applications developed to operate over Category 6 or class E cabling
n
n
n
10GBASE-T
n 2
n
n
All other applications developed to operate
Category 6A or class EA cabling
n
n
All other applications developed to operate
over Category 7 or class F cabling n
Guaranteed Category 5e support of IEEE 1000BASE-T (Gigabit Ethernet) application:
Hitachi Cable Manchester, Inc.’s Category 5e cables exceed all of the requirements specified by IEEE 8023.ab for support of
Gigabit Ethernet (1000BASE-T) operation over twisted-pair cabling. Furthermore, HCM guarantees that all of our Category 5e and
higher rated cables will support the 1000BASE-T application.
To demonstrate our compliance, HCM’s products have been extensively tested for 1000BASE-T throughput at the University of
New Hampshire’s Interoperability Lab and found to fully support the IEEE 100BASE-T Gigabit Ethernet application.
Cat 7 Cable standard has not yet been ratified.
Per TSB-155, Category 6 UTP may accommodate 10GBASE-T to 55m (channel length) and Category 6 FUTP may accommodate
10GBASE-T to 100m (channel length). Mitigation may be required to achieve optimum channel lengths.
1
2
90
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Applications
Support
Fiber
Applications Support Matrix
Standard
Wavelength
Transmission
1000BASE-LX
1300nm
Serialized
10GBASE-SR
Application
10GBASE-LR
850nm
850nm
1310nm
Serialized
Serialized
Serialized
10GBASE-LRM
1310nm
Serialized
10GBASE-ER
1550nm
Serialized
10GBASE-LX4
1300nm
WDM
40GBASE-SR4
850nm
Parallel Optics
40GBASE-LR4
1310nm
WDM
100GBASE-SR10
850nm
Parallel Optics
100GBASE-LR4
1310nm
WDM
100GBASE-ER4
1310nm
WDM
Infiniband SDR
Infiniband DDR
Infiniband 4x-LX
ITU-T G.957 STM-1, -4
& -16
ITU-T G.957 STM-1 & -4
850nm
850nm
call
1550nm
ITU-T G.957 STM-1
Fibre Channel, 2 Gig
Parallel Optics
Parallel Optics
call
WDM
OM1
550
OM2
550
SM
>2,000
OM1
220
OM2
550
OM3
>550
OM1
33
OM2
82
OM3
300
OM4
550
SM
10,000 - 25,000
OM1
220
OM3
260
SM
40,000
MM
240-300
SM
10,000
OM3
100
OM4
125
SM
10,000
OM3
100
OM4
125
SM
10,000
SM
40,000
OM1
75
OM2
125
OM3
200
OM1
50
OM2
75
OM3
150
OS2
10,000
2,000
OS2
Serialized
850nm
Serialized
Fibre Channel, 4 Gig
850nm
Serialized
Fibre Channel 1, 2
& 4 Gig
1300nm
Serialized
www.hcm.hitachi.com
Length (m)
Applications
1000BASE-SX
Fiber type
15,000
40,000
OM2
300
OM3
500
OM2
150
OM3
270
OS2
10,000
91
Standards
Reference
All of HCM’s cables are fully compliant to the requirements of applicable national
and international structured cabling standards.
TIA-568-C.0 “Generic Telecommunications Cabling Standard
(2009)” This standard, in part, supersedes TIA/EIA-568-B.1 and
its addenda. This standard incorporates the following standards:
TIA/EIA-568-B.1-1, TIA/EIA-568-B.1-2, TIA/EIA-568-B.1-3, TIA/
EIA-568-B.1-7, TIA/EIA TSB125, TIA TSB140, TIA TSB153. This
document specifies copper and fiber optic cabling requirements
and test methods that will support a multi-product, multi-vendor
environment.
TIA-568-C.1 “Commercial Building Telecommunications Cabling
Standard (2009)” This standard, in part, supersedes TIA/EIA568-B.1 and its addenda. This standard incorporates content
from ANSI/TIA-568-B.1-4, Addendum 4, as well as ANSI/TIA568-B.1-5, Addendum 5.
TIA-568-C.2 “Balanced Twisted Pair Telecommunications
Cabling Components Standard (2009)” This standard supersedes
ANSI/TIA/EIA-568B.2. This document specifies the performance
of copper cables, patch cords, and connectors, in addition
to the transmission, system models, and the measurement
procedures needed for verification of balanced twisted pair
cabling performance. This standard incorporates content from
the following ANSI/TIA/EIA standards: 568-B.2, 568-B.2-1, 568B.2-2, 568-B.2-3, 568-B.2-4, 568-B.2-5, 568-B.2-6 and ANSI/TIA
standards 568-B.2-7, 568-B.2-9, 568-B.2-10 and 568-B.2-11.
TIA-568-C.3 “Optical Fiber Cabling Components Standard
(2008)” This document specifies the performance of the cables,
patch cords, and connector used in fiber optic cable systems.
This standard replaces ANSI/TIA/EIA-568-B.3 and ANSI/TIA/EIA568-B.3-1.
TIA/EIA-568-B.1 “Commercial Building Telecommunications
Cabling Standard – Part 1:General Requirements (2001)”
This document specifies copper and fiber optic cabling
requirements and test methods that will support a multi-product,
multi-vendor environment.
TIA/EIA-568-B.1-1 “Commercial Building Telecommunications
Cabling Standard – Part 1: General Requirements –
addendum 1 – Minimum 4-pair UTP and 4-Pair ScTP Patch
Cable Bend Radius (2001)” This addendum specifies minimum
bend radius requirements for 4-pair unshielded twisted-pair (UTP)
and 4-pair screened twisted-pair (ScTP) patch cable.
TIA/EIA-568-B.2 “Commercial Building Telecommunications
Cabling Standard – Part 2: Balanced Twisted Pair Cabling
Components (2001)” This document specifies the performance
92
HITACHI CABLE MANCHESTER, INC.
of copper cables, patch cords, and connectors, in addition
to the transmission, system models, and the measurement
procedures needed for verification of balanced twisted pair
cabling performance.
TIA/EIA-568-B.2-1 “Commercial Building Telecommunications
Cabling Standard – Part 2: Balanced Twisted Pair
Components – Addendum 1 – Transmission Performance
Specifications for 4-Pair 100 Ohm Category 6 Cabling
(2002)” This document specifies requirements for category 6
cabling, cables, and connecting hardware.
TIA/EIA-568-B.2-10 “Commercial Building Telecommunications
Cabling Standard – Part 2: Balanced Twisted Pair Cabling
Components – Addendum 10 – Transmission Performance
Specifications for 4-Pair 100 Ohm Augmented Category 6
Cabling (2007)” This document specifies the requirements for
Category 6A cabling, cables and connecting hardware.
TIA/EIA –568-B-3.1 “Optical Fiber Cabling Components
Standard – addendum 1 – Additional Transmission
Performance Specifications for 50/125 um Optical Fiber
Cables (2002)” This addendum specifies additional component
and transmission requirements for 50/125 um optical fiber cables
capable of supporting 10 Gb/s serial transmission up to 300 m
(984 ft) using 850 nm nominal wavelength lasers.
TIA/EIA-569-B “Commercial Building Standard for
Telecommunications Pathways and Spaces (2003)” This
document describes recognized cabling locations both within
and between buildings. Included are the pathways in which
telecommunications media are placed and the rooms and areas
associated with the building used to terminate media and install
telecommunications equipment.
TIA/EIA-570-A “Residential Telecommunications Cabling
Standard (2001)” The purpose of this document is to
standardize requirements for residential telecommunications
cabling. The requirements are intended to be implemented for
new construction, additions and remodeled single and multitenant residential buildings.
TIA/EIA-606-A “Administration Standard for Commercial
Telecommunications Infrastructure (2003)” This standard
provides guidelines and choices of classes of administration for
maintaining telecommunications infrastructure.
1.800.772.0116
Configurations
Test
Standards (continued)
TIA/EIA-607-A “Commercial Building Grounding (Earthing)
and Bonding Requirements for Telecommunications (2001)”
This purpose of this standard is to enable the planning, design,
and installation of telecommunications grounding and bonding
systems within a building with or without prior knowledge
of the telecommunications systems that will subsequently be
installed.
TIA/EIA-758-A “Customer-Owned Outside Plant
Telecommunications Infrastructure (2003)” This standard
provides requirements used in the design of the cabling,
pathways and spaces used between buildings or points in a
customer-owned campus environment.
TI/EIA-862 “Building Automation Systems cabling Standard
for Commercial Buildings (2002)” This standard specifies a
generic cabling system for building automation systems (BAS)
used in commercial systems.
ISO/IEC 11801, 2nd edition “Generic cabling for Customer
Premises (2002)” This standard is the international
counterpart to the TIA/EIA-568-B family of standards. It
contains requirements for balanced twisted-pair and fiber optic
components and cabling systems.
TSB 155 “Guidelines for the Assessment of Mitigation of
Installed Category 6 Cabling to Support 10GBASE-T” This
document specifies the requirements for Category 6 UTP and
ScTP (FTP) in regards to accommodating 10GBASE-T Ethernet.
Channel Configuration
Standards
The channel test configuration is to be used by system designers and users of data communications systems to verify the
performance of the overall channel. The channel includes up to 90 m (295 ft) of horizontal cable, a work area equipment cord,
a telecommunications outlet/connector, an optional transition/consolidation connector, and two connections in the telecommunications
room. The total length of equipment cords, patch cords or jumpers and work area cords shall not exceed 10 m (33 ft). Note
that the connections to the equipment at each end of the channel are not included in the channel definition.
Maximum length B + C < 90 m (295 ft);
A + D + E < 10 m (32.8 ft)
Permanent Link
The permanent link test configuration is to be used by installers and users of data telecommunications systems to verify the
performance of permanently installed cabling. The permanent link consists of up to 90 m (295 ft) of horizontal cabling and one
connection at each end and may also include an optional transition/consolidation point connection. Note that the permanent link
excludes both the cable portion of the field test instrument cord and the connection to the field test instrument.
Maximum length B + C < 90 m (295 ft)
Cables and cords A =Work area cord
B =Optional transition cabling
C = Horizontal cabling
www.hcm.hitachi.com
D =Patch cord or jumper cable
E =Telecommunications room equipment cord
F =Test equipment cord
Connecting Hardware
WA =Telecommunications outlet/connector
CP = Optional transition/consolidation point connector
C1, C2 = Horizontal cross-connect or interconnect
93
Glossary
Acronyms & Abbreviations
ACR: Attenuation-to-crosstalk ratio
ACRF: Attenuation-to-crosstalk ratio far-end
ANSI: American National Standards Institute
ASTM: American Society for Testing and Materials
ATM: asynchronous transfer mode
AWG: American Wire Gauge
BELLCORE: Bell Communications Research
BICSI: Building Industry Consulting Services International
CATV: community antenna television
EIA: Electronic Industries Alliance
ELFEXT: equal level far-end crosstalk
EMC: electromagnetic compatibility
EMI: electromagnetic interference
FCC: Federal Communications Commission
FDDI: fiber distributed data interface
FEXT: far-end crosstalk
FOCIS: Fiber Optic Connector Intermateability Standard
F/UTP: foil over unshielded twisted pairs
IEC: International Electrotechnical Commission
IEEE: The Institute of Electrical and Electronics Engineers
ILD: Insertion loss deviation
LCL: Longitudinal conversion loss
LCTL: Longitudinal conversion transfer loss
ISDN: integrated services digital network
ISO: International Organization for Standardization
LAN: local area network
LED: light emitting diode
Mb/s: megabits per second
MUTOA: multi-user telecommunications outlet assembly
NEC®: National Electrical Code®
NEMA: National Electrical Manufacturers Association
NESC®: National Electrical Safety Code®
NEXT: near-end crosstalk
NFPA: National Fire Protection Association
NVP: nominal velocity of propagation
PSACR: power sum attenuation-to-crosstalk ratio
PSACRF: power sum attenuation-to-crosstalk ratio far-end
PSELFEXT: power sum equal level far-end crosstalk
PSFEXT: power sum far-end crosstalk
PSNEXT: power sum near-end crosstalk
SFTP: braided shield over pairs in foil
STP: shielded twisted-pair
TIA: Telecommunications Industry Association
TSB: Telecommunications System Bulletin
UL: Underwriters Laboratories
UTP: unshielded twisted-pair
94
HITACHI CABLE MANCHESTER, INC.
adapter (copper): A device
that enables any or all of
the following: (1) different
sizes or types of plugs to
mate with one another or to
fit into a telecommunications
outlet, (2) the rearrange­ment
of leads, (3) large cables
with numerous wires to fan
out into smaller groups of
wires, and (4) interconnection
between cables.
adapter (fiber optic): optical
fiber duplex: A mechanical
device designed to align and
join two duplex optical fiber
connectors (plugs) to form
an optical duplex connection.
administration:
The method for labeling,
identification, documentation
and usage needed
to implement moves,
additions and changes of
the telecommunications
infrastructure.
attenuation:
(see insertion loss)
attenuation-to-crosstalk
ratio: A ratio, expressed in
dB, determined by subtracting
the insertion loss from the
near-end crosstalk loss.
attenuation-to-crosstalk
ratio far-end: replaces
ELFEXT. A measure of the
unwanted signal coupling
from a transmitter at the
near-end into another pair
measured at the far-end, and
relative to the received signal
level.
backbone cable:
A cable that runs between
telecommunications rooms, or
floor distribution terminals,
the entrance facilities, and the
equipment rooms within or
between buildings.
balance: Balance is the
ratio of the differential signal
output at either end of any
pair to a common mode
signal input, at either end
of the same or a different
pair, and vice versa,
under specified termination
conditions.
bonding: The permanent
joining of metallic parts to
form an electrically conductive
path that will assure electrical
continuity and the capacity
to conduct safely any current
likely to be imposed on it.
bundled cable:
An assembly of two or more
cables continuously bound
together to form a single
unit.
cable: An assembly of one
or more insulated conductors
or optical fibers, within an
enveloping sheath.
cable run: A length of
installed media, which may
include other components
along its path.
cable sheath:
A covering over the optical
fiber or conductor assembly
that may include one or
more metallic members,
strength members, or jackets.
cabling: A combination of
all cables, jumpers, cords,
and connecting hardware.
campus: The buildings
and grounds having legal
contiguous interconnection.
centralized cabling:
A cabling configuration
from the work area to a
centralized cross-connect
using pull through cables, an
interconnect, or splice in the
telecommunications room.
channel: The end-to-end
transmission path between
two points at which
application-specific equipment
is connected.
1.800.772.0116
Glossary
connecting hardware: A
device providing mechanical
cable terminations.
connector, small form
factor: An optical fiber
duplex connector with a size
approximating that of an
8-position modular outlet/
connector typically used for
terminating 4-pair copper
cable.
cord (telecommunications):
A cable using stranded
conductors for flexibility, as
in distribution cords or line
cords.
cross-connect:
A facility enabling the
termination of cable elements
and their interconnection or
cross-connection.
entrance facility
(telecommunications):
An
entrance to a building for
both public and private
network service cables
(including wireless) including
the entrance point of the
building and continuing to
the entrance room or space.
entrance point
(telecommunications):
The
point of emergence for
telecommunications cabling
through an exterior wall, a
floor, or from a conduit.
entrance room
or space (telecommunications):
A space in which the joining
of inter or intra building
telecommunications backbone
facilities takes place.
equal level far-end
crosstalk: (obsolete) A
measure of the unwanted
signal coupling from a
transmitter at the near-end
into another pair measured
at the far-end, and relative to
the received signal level.
decibels (dB):
A logarithmic unit that is
used to describe a wide
range of differences in signal
voltage or power levels.
equipment cable, cord: A
cable or cable assembly used
to connect telecommunications
equipment to horizontal or
backbone cabling.
delay skew: The difference
in propagation delay between
any two pairs within the
same cable sheath.
demarcation point:
A point where the operational
control or ownership changes.
drain wire: A non-insulated
conductor placed in electrical
contact with a shield.
electromagnetic
interference: Radiated
or conducted electro­
magnetic energy that has
an undesirable effect on
electronic equipment or signal
transmissions.
www.hcm.hitachi.com
equipment room
(telecommunications):
An
environmentally controlled
centralized space for
telecommunications equipment
that usually houses a main
or intermediate cross-connect.
high-order mode transient
losses: Losses in power
caused by the attenuation in
the cladding of multimode
optical fiber.
horizontal cabling: (1)The
cabling between and including
the telecommunications outlet/
connector and the horizontal
cross-connect.
(2) The cabling between
and including the building
automation system outlet
or the first mechanical
termination of the horizontal
connection point and the
horizontal cross-connect.
horizontal cross-connect:
A cross-connect of horizontal
cabling to other cabling, e.g.,
horizontal, backbone, and
equipment.
hybrid cable: An assembly
of two or more cables, of
the same or different types
or categories, covered by one
overall sheath.
Glossary
cross-connection:
A connection scheme between
cabling runs, subsystems,
and equipment using patch
cords or jumpers that attach
to connecting hardware on
each end.
an electrical circuit (e.g.,
telecommunications) or
equipment and the earth, or
to some conducting body
that serves in place of earth.
hybrid optical fiber
cable: An optical fiber cable
containing two or more fiber
types (e.g., multimode and
singlemode).
far-end crosstalk loss: A
measure of the unwanted
signal coupling from a
transmitter at the near end
into another pair measured at
the far end.
fiber optic: See optical
fiber.
ground: A conducting
connection, whether intentional
or accidental, between
95
Glossary
infrastructure
(telecommunications):
A collection
of those telecommunications
components, excluding
equipment, that together
provide the basic support
for the distribution of all
information within a building
or campus.
insertion loss: The signal
loss resulting from the
insertion of a component, or
link, or channel, between a
transmitter and receiver.
insertion loss deviation:
The difference between the
actual insertion loss as
measured on a permanent
link or channel and the
insertion loss as determined
by adding the component
losses.
interconnection:
A connection scheme that
employs connecting hardware
for the direct connection
of a cable to another cable
without a patch cord or
jumper.
intermediate
cross-connect: A crossconnect between first level
and second level backbone
cabling.
intrabuilding
telecommunications
backbone: A pathway or
cable facility for interconnect­
ing telecommu­nications service
entrance rooms, equipment
rooms, or telecommunications
rooms within a building.
jumper: An assembly
of twisted-pairs without
connectors, used to join
telecommunications circuits/
links at the cross-connect.
96
HITACHI CABLE MANCHESTER, INC.
keying: The mechanical
feature of a connector system
that guarantees correct
orientation of a connection,
or prevents the connection to
a jack, or to an optical fiber
adapter of the same type
intended for another purpose.
megahertz (MHz):
Transmitted signal frequency
described as the number of
millions of sinusoidal signal
cycles per second.
link: A transmission path
between two points, not
including terminal equipment,
work area cables, and
equipment cables.
modular jack: A female
telecommunications connector
that may be keyed or
unkeyed and may have 6
or 8 contact positions, but
not all the positions need be
equipped with jack contacts.
longitudinal conversion
loss: A ratio, expressed in
dB, of measured differential
voltage relative to the
common mode voltage on a
conductor pair applied at the
same end.
longitudinal conversion
transfer loss: A ratio,
expressed in dB, of measured
differential voltage at one end
of a conductor pair relative
to the common mode voltage
applied on any pair at the
opposite end or on any other
pair on the same end.
main cross-connect: A
cross-connect for first level
backbone cables, entrance
cables, and equipment cables.
main terminal space: The
location of the cross-connect
point of incoming cables
from the telecommu­nications
external network and the
premises cable system.
megabits per second
(Mbps): An application
dependent specification
describing the number of
discrete bits of information
(i.e. a “1” or a “0”)
transmitted per second.
mode: A path of light in
an optical fiber.
modular plug cord:
A length of cable with a
modular plug on both ends.
multimode optical fiber:
An optical fiber that carries
many paths of light.
multipair cable:
A cable having more than
four pairs.
multi-user
telecommunications outlet
assembly: A grouping
in one location of several
telecommunications outlet/
connectors.
open office: A floor space
division provided by furniture,
moveable partitions, or other
means instead of by building
walls.
optical fiber: Any filament
made of dielectric materials
that guides light.
optical fiber cable:
An assembly consisting of
one or more optical fibers.
optical fiber duplex
connection: A mated
assembly of two duplex
connectors and a duplex
adapter.
1.800.772.0116
Glossary
outlet/connector
(telecommunications):
A connecting device in
the work area on which
horizontal cable or outlet
cable terminates.
patch cord: A length of
cable with a plug on one or
both ends.
patch panel: A connecting
hardware
system that facilitates cable
termination and cabling
administration using patch
cords.
pathway: A facility for the
placement of telecommu­
nications cable.
permanent link: A test
configuration for a link
excluding test cords and
patch cords.
power sum attenuationto-crosstalk ratio: A ratio,
expressed in dB, determined
by subtracting the insertion
loss from the power sum
near-end crosstalk loss.
power sum attenuationto-crosstalk ratio farend: replaces PSELFEXT. A
computation of the unwanted
signal coupling from multiple
transmitters at the near-end
into a pair measured at the
far-end, and normalized to
the received signal level.
power sum equal level
far-end crosstalk:(obsolete)
A computation of the
unwanted signal coupling
from multiple transmitters
at the near-end into a pair
measured at the far-end, and
normalized to the received
signal level.
www.hcm.hitachi.com
propagation delay: The
time required for a signal
to travel from one end of
the transmission path to the
other end.
return loss: A ratio
expressed in dB of the
power of the outgoing signal
to the power of the reflected
signal.
room (telecommunications): An
enclosed space for housing
telecommunications equipment,
cable terminations, and crossconnect cabling, that is the
recognized location of the
horizontal cross-connect.
screen: An element of a
cable formed by a shield.
screened twisted-pair
(ScTP): A balanced cable
with an overall screen.
shield: A metallic layer
placed around a conductor or
group of conductors.
singlemode optical fiber:
An optical fiber that carries
only one path of light.
splice: A joining of
conductors in a splice
closure, meant to be
permanent.
splice closure: A device
used to protect a splice.
star topology: A topology
in which telecom­mu­­nications
cables are distributed from a
central point.
telecommunications:
Any transmission, emission,
and reception of signs,
signals, writings, images, and
sounds, that is information
of any nature by cable,
radio, optical, or other
electromagnetic systems.
Units of Measure
oC
degrees Celsius
oF
degrees Fahrenheit
dB
decibel
topology: The physical or
logical arrangement of a
telecommunications system.
ft
foot
GHz
gigahertz
in
transfer impedance:
A measure of shielding
performance determined by
the ratio of the voltage on
the conductors enclosed by a
shield to the surface currents
on the outside of the shield.
inch
km
kilometer
lbf
pound force
m
meter
MHz
megahertz
mm
millimeter
transition point:
A location in the horizontal
cabling where flat undercarpet
cable connects to round
cable.
N
newton
nm
nanometer
ns
nanosecond
Vrms
volts root mean square
µm
micron or micrometer
work area (work station):
A building space where
the occupants interact with
telecommunications terminal
equipment.
work area cable (cord):
A cable connecting the
telecommunications outlet/
connector to the terminal
equipment
Conversion Table
English to Metric
Glossary
plenum: A compartment or
chamber to which one or
more air ducts are connected
and that forms part of the
air distribution system.
power sum nearend crosstalk loss: A
computation of the unwanted
signal coupling from multiple
transmitters at the far-end
into a pair measured at the
near-end
Multiply by:
from inches to centimeters
2.54
from feet
to meters
0.3048
from yards
to meters
0.9144
from ounces
to grams
28.3495
from pounds
to kilograms
0.453592
from Fahrenheit (F) C=(F-32)
to Celsius (C)
x 0.555
97
Part Number
Fiber
Part #
98
Page #
Part #
Page #
Part #
Page #
Part #
Page #
Part #
Page #
Part #
Page #
60001
52
60052
50
60344
80
60492
54
60604
62
60722
80
60002
52
60056
50
60345
86
60494
54
60613
60
60932
86
60003
52
60063
52
60346
86
60501
52
60614
62
60933
86
60004
52
60085
84
60351
84
60502
54
60621
60
60934
86
60005
52
60086
84
60356
86
60514
52
60621
60
60937
86
60006
52
60087
84
60356
86
60515
56
60622
62
60938
84
60007
52
60088
84
60369
60
60517
58
60622
62
60939
84
60008
54
60089
84
60405
72
60518
58
60627
60
60940
84
60009
60
60090
84
60408
84
60520
56
60627
60
60943
84
60010
52
60097
86
60423
54
60522
58
60628
62
60944
86
60011
52
60098
86
60424
54
60524
70
60628
62
60945
86
60012
52
60101
86
60425
52
60559
62
60633
60
60946
86
60014
56
60101
86
60430
54
60564
60
60633
60
60949
86
60015
60
60102
86
60431
54
60565
62
60634
62
60950
84
60015
60
60102
86
60432
54
60567
60
60634
62
60951
84
60022
54
60103
78
60462
52
60569
60
60638
60
60954
86
60023
54
60104
78
60463
52
60570
62
60638
60
60954
86
60024
54
60105
78
60464
52
60581
60
60639
62
61319
72
60026
54
60106
80
60465
52
60582
62
60639
62
61321
51
60027
62
60107
80
60466
52
60585
60
60639
62
61337
72
60028
62
60108
80
60467
52
60586
60
60701
80
61345
74
60029
58
60109
80
60468
54
60588
60
60702
80
61347
74
60030
54
60110
80
60469
51
60589
62
60710
80
61348
74
60031
54
60111
80
60470
54
60591
60
60711
80
61349
74
60033
62
60116
50
60471
54
60592
62
60712
80
61355
51
60033
62
60136
50
60472
54
60594
60
60714
80
61363
74
60037
52
60145
50
60473
54
60595
60
60715
80
61376
74
60038
52
60150
50
60474
54
60596
62
60716
80
61380
74
60039
52
60235
84
60475
54
60598
62
60717
80
60040
52
60258
62
60489
52
60600
60
60719
80
60042
54
60282
84
60490
54
60601
62
60720
80
60044
54
60337
78
60491
54
60603
60
60721
80
HITACHI CABLE MANCHESTER, INC.
1.800.772.0116
Part Number
Reference
Fiber
Part #
Page #
Part #
Page #
Part #
Page #
Part #
Page #
Part #
Page #
74
61653
52
61727
66
61865
56
61907
84
61971
82
61421
70
61653
52
61732
66
61867
58
61908
84
61971
82
61433
72
61655
52
61733
66
61868
58
61909
86
61972
82
61459
76
61657
52
61734
66
61870
60
61910
86
61972
82
61460
76
61659
52
61735
66
61871
60
61911
86
61973
82
61461
54
61661
52
61736
66
61872
60
61912
86
61973
82
61464
76
61661
56
61737
66
61873
60
61952
82
61974
82
61468
76
61663
52
61738
66
61874
60
61952
82
61974
82
61480
76
61665
52
61739
66
61875
62
61953
82
61975
82
61488
54
61679
54
61778
66
61876
62
61953
82
61975
82
61492
54
61679
54
61779
66
61877
62
61954
82
61976
82
61493
54
61681
54
61780
66
61878
62
61954
82
61976
82
61495
74
61683
54
61781
66
61882
64
61955
82
61977
82
61506
66
61685
54
61790
52
61883
66
61955
82
61977
82
61507
66
61687
54
61791
52
61884
68
61956
76
61978
82
61509
68
61687
58
61792
52
61889
66
61959
76
61978
82
61510
52
61689
54
61793
52
61890
66
61963
82
61979
76
61511
52
61691
54
61825
66
61891
66
61963
82
61980
76
61512
52
61705
56
61837
78
61892
66
61964
82
61981
76
61515
52
61707
58
61838
52
61893
74
61964
82
61522
74
61713
64
61842
52
61894
76
61965
82
61523
74
61715
66
61843
52
61896
70
61965
82
61524
74
61717
68
61844
52
61897
72
61966
82
61538
66
61719
74
61851
54
61898
74
61966
82
61538
66
61721
76
61851
54
61899
74
61967
82
61539
64
61723
78
61852
54
61900
80
61967
82
61540
72
61724
66
61853
54
61901
80
61968
82
61542
70
61724
66
61854
54
61902
80
61968
82
61546
64
61725
66
61855
54
61903
80
61969
82
61547
64
61725
66
61856
54
61904
80
61969
82
61549
68
61726
66
61857
54
61905
84
61970
82
61550
68
61726
66
61864
56
61906
84
61970
82
www.hcm.hitachi.com
Reference
Page #
61415
Part Number
Part #
99
Installation
Reference
Since 1986, Hitachi Cable Manchester has been devel-
Conduit Fill Chart
oping technologically advanced copper and fiber
engineering perfection is evident in the consistent
quality and performance of all the cable products
we manufacture. Through the development of
unique cable products
such as the world’s only UL verified 25-pair Category
5e CMP cable and the world’s
first UL verified 10 Gigabit UTP cable, HCM
has established itself as a leader in the industry.
These products and the others found in this catalog
are the result of HCM’s relentless desire to manufacture the finest communication cables in the industry.
After using our products, we’re sure you’ll agree.
Conduit Size
1/2”
3/4”
1”
40% Int. Area 0.19”
0.2”
0.21”
0.22”
0.23”
0.24”
0.25”
0.26”
0.27”
0.28”
0.29”
0.3”
0.31”
0.32”
0.33”
0.34”
0.35”
0.121”
4
4
3
3
3
2
2
1
1
1
1
1
1
1
1
1
1
0.213”
7
6
6
5
5
4
4
4
3
3
3
3
3
2
2
2
1
.345”
12
11
10
9
8
7
7
6
6
5
5
5
4
4
4
4
3
Cable Diameter
optic communication cables. Our dedication to
1-1/4” 1-1/2”
.598”
21
19
17
15
14
13
12
11
10
9
9
8
8
7
7
6
6
.814”
28
26
23
21
19
18
16
15
14
13
12
11
10
10
9
9
8
2”
2-1/2”
3”
3-1/2”
4”
1.342”
47
42
38
35
32
29
27
25
23
21
20
19
17
16
15
14
14
2.343”
82
74
67
61
56
51
47
44
41
38
35
33
31
29
27
26
24
3.538”
124
112
102
93
85
78
72
66
61
57
53
50
47
44
41
39
36
4.618”
163
147
133
121
111
102
94
87
80
75
70
65
61
57
54
51
48
5.901”
208
188
170
155
142
130
120
111
103
96
89
83
78
73
69
65
61
The above conduit fill chart is for reference only. The conduit capacity is based on the National Electical Code requirement of 40% maximum fill. To determine
the maximum conduit fill for cable O.D.s other than those referenced above, use the following steps: 1. Square the O.D. of the cable. 2. Multiple the result by
.7854. This is the total area of the cable. 3. Multiple the total area of the cable by the number of cables you wish to place in the conduit. This is the total
area of the cable bundle. Determine the appropriate conduit size by referencing the 40% Interior Area row.
Storage, Installation & Operation Temperatures
Indoor Copper Cables
Indoor Fiber Optic Cables
Storage Temperature
-40°C to +60°C (-40°F to +140°F)
-40°C to + 80°C (-40°F to +176°F)
Installation Temperature
0°C to +60°C (+32°F to +140°F)
0°C to + 50°C (+32°F to +122°F)
Operation Temperature
-20°C to +50°C (-4°F to +122°F)
-20°C to + 80°C (-4°F to +176°F)
Storage Temperature
Outdoor Copper Cables
Outdoor Fiber Optic Cables
-40°C to +70°C (-40°F to +158°F)
-40°C to + 70°C (-40°F to +158°F)
Installation Temperature
-20°C to +70°C (-4°F to +158°F)
-20°C to + 70°C (-4°F to +158°F)
Operation Temperature
-40°C to +70°C (-40°F to +158°F)
-40°C to + 70°C (-40°F to +158°F)
Product Performance Guarantee
www.hcm.hitachi.com
Reference
All of our cables are manufactured in our state-of-the-art facility located in Manchester, NH.
Contact our knowledgeable customer service representatives at 1.800.772.0116 for assistance.
Installation
All goods sold are warranted to be free from defects in material and workmanship on the date of delivery of the materials to the
F.O.B. point stated. Seller makes no representation or warranty of any kind, expressed or implied with respect to the goods sold hereunder, whether as to merchantability, fitness for particular purpose, or any other matter. Seller’s only obligation is to replace goods
that are proved defective within one (1) year after the date of delivery, but always provided the product receives normal and proper
use, and due care in handling is exercised. If the goods purchased show defects in material or workmanship within one (1) year after
date of delivery, Buyer must discontinue use thereof and must properly notify Seller, so that the matter may be investigated and material inspected and examined by the Seller without inference or delay. Contact HCM for full warranty details.
129
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF