AKH/AKB Series - Check Valve with One

Add to my manuals
12 Pages

advertisement

AKH/AKB Series - Check Valve with One | Manualzz
N373
®
AKH/AKB Series
Check Valve with One-touch Fitting
Bushing Type
Can be used in applications with
splashing coolant and spatter, etc.
Male Connector Type
Can be mounted directly
onto equipment
Straight Type
Easily installed in pipe lines
Symbol
Can be used for vacuum (–100kPa)
IN
IN
OUT
OUT
Free flow direction
Check direction
Compact & Light weight
Valve
With One-touch fitting
Outside diameter: ø11.6mm
Overall length: 37.1mm
Weight: 5g
Low cracking pressure: 0.005MPa
Large effective area: 3 to 34mm²
Reduces piping labor
(for AKH06-00)
Release button color
Millimeter size: White
Inch size: Orange
Series AKH/AKB
Check Valve with One-Touch Fitting
How to Order
AKH 04 00
Male Connector Type
AKH 04 A
Straight Type
01 S
With sealant (standard)
∗ Not applicable to types M5 & 10-32UNF are not required.
Applicable tube O.D.
Millimeter size
Inch size
04
ø4
03
ø5/32
06
ø6
07
ø1/4
08
ø8
09
ø5/16
10
ø10
11
ø3/8
12
ø12
13
ø1/2
Port size
M5 x 0.8
M5
U10/32 10-32UNF
Thread type
Metric system thread (M5)
Unified thread (10-32UNF)
Nil
Rc(PT)
N
NPT
01
1/8
02
1/4
03
3/8
04
1/2
Check valve free flow direction
Applicable Tube O.D. /Port Size Combinations
A
B
Bushing Type
From male thread
to one-touch
fitting
Millimeter size
Model
AKH04
AKH06
AKH08
AKH10
AKH12
From one-touch
fitting to male
thread
AKB 01 A
Inch size
Applicable
tube O.D.
ø4
ø6
ø8
ø10
ø12
Port size Rc(PT)
M5 1/8 1/4 3/8 1/2
Model
AKH03
AKH07
AKH09
AKH11
AKH13
Applicable
tube O.D.
ø5/32"
ø1/4"
ø5/16"
ø3/8"
ø1/2"
Port size NPT
1/8 1/4 3/8 1/2
10-32
UNF
01 S
With sealant (standard)
Body size
01
1/8
02
1/4
03
04
3/8
1/2
Port size
Thread type
Nil
R
N
NPT
01
1/8
02
1/4
03
3/8
04
1/2
Check valve free flow direction
A
From male
thread to
female thread
Female Thread/Male Thread Combinations
From female
thread to male
thread
Female thread Male thread R
Rc(PT)
1/8 1/4 3/8 1/2
1/8
1/4
3/8
1/2
R(PT) thread
Model
B
®
2
AKB01
AKB02
AKB03
AKB04
NPT thread
Model
AKB01
AKB02
AKB03
AKB04
Female thread Male thread NPT
NPT
1/8 1/4 3/8 1/2
1/8
1/4
3/8
1/2
Series AKH/AKB
Check Valve with One-Touch Fitting
Specifications
Fluid
Air
Proof pressure
1.5MPa (217.5psi)
Operating pressure range
– 100kPa to 1MPa (-14.5 to 145psi)
Cracking pressure
0.005MPa (0.7psi)
Ambient and fluid temperature
– 5 to 60°C (23 to 140°F) (with no freezing)
Applicable tube material Note 1)
Nylon, Soft nylon, Polyurethane
Note 1) Use caution at the maximum operating pressure with soft nylon and polyurethane.
(Refer to CAT.E501- B "Air Fittings and Tubing" for details.)
Application Examples for Check Valve with One-Touch Fitting
Prevention of reverse flow to vacuum source ∗
(simple vacuum holding)
Tank pressure reverse flow prevention
Drop prevention ∗
∗ A certain amount of leakage is allowed in the specifications of this product. Please note that it is not suitable for holding over an extended period of time.
®
3
Series AKH/AKB
Check Valve with One-Touch Fitting
Dimensions (mm)
1in=25.4mm
Straight Type: AKH
Millimeter Size
øD
2-Applicable tubing
M
M
L
Male Connector Type: AKH
<For M5, UNF10-32>
Applicable tubing
Applicable
tube O.D.
Model
øD
L
M
Effective area
(mm²)
Weight
g
4
6
8
10
12
AKH04-00
AKH06-00
AKH08-00
AKH10-00
AKH12-00
9.3
11.6
15.2
18.5
21.7
33.5
37.1
53.3
63.6
70.2
12.7
13.5
18.5
21
22
2.8
6.5
14
24
34
3
5
10
17
25
Applicable
tube O.D.
Model
øD
L
M
Effective area
(mm²)
Weight
g
5/32
1/4
5/16
3/8
1/2
AKH03-00
AKH07-00
AKH09-00
AKH11-00
AKH13-00
9.3
12
15.2
18.5
21.7
33.5
39
53.3
63.6
70.2
12.7
13.6
18.5
21
22
2.8
6.5
14
24
34
3
6
10
17
24
Inch Size
Millimeter Size
Applicable
tube O.D.
4
6
M
H
L
A
8
10
12
Connection thread
Connection
thread R
Model
M5 x 0.8
1/8
M5 x 0.8
1/8
1/4
1/8
1/4
3/8
1/4
3/8
1/2
3/8
1/2
AKH04-M5
AKH04-01S
AKH06-M5
AKH06-01S
AKH06-02S
AKH08-01S
AKH08-02S
AKH08-03S
AKH10-02S
AKH10-03S
AKH10-04S
AKH12-03S
AKH12-04S
H
L
8
10
24.3
24.6
25.8
26.9
30
31.7
(Width across flats)
10
14
14
42
17
54.3
47.3
49.3
60.5
54.5
17
22
19
22
Applicable
tube O.D.
Applicable tubing
5/32
A
M
H
1/4
L
5/16
3/8
Connection thread
1/2
21.2
20.6
22.2
22.9
24
27.7
36
35.5
48.3
40.8
41.3
54
46.5
M
12.7
13.5
17
18.5
Effective area Weight
(mm²)
g
2.8
2.8
6.5
6.5
6.5
14
21
24
22
34
5
10
8
22
16
24
43
45
39
80
62
80
∗ Reference dimension after screwing into R threads.
Inch Size
<For R, NPT>
A∗
Connection
thread NPT
Model
10-32 UNF
1/8
10-32 UNF
1/8
1/4
1/8
1/4
3/8
1/4
3/8
1/2
3/8
1/2
AKH03-U10/32
AKH03-N01S
AKH07-U10/32
AKH07-N01S
AKH07-N02S
AKH09-N01S
AKH09-N02S
AKH09-N03S
AKH11-N02S
AKH11-N03S
AKH11-N04S
AKH13-N03S
AKH13-N04S
H
(Width across flats)
8
11.11
11.11
14.29
14.29
17.46
17.46
22.23
22.23
L
24.3
24.6
25.8
26.9
31
31.7
42
54.2
47.2
49.2
60.5
54.5
A∗
21.2
20.6
22.7
22.9
25
27.7
36
35.5
48.3
40.7
41.2
54
46.5
M
12.7
13.6
17
18.5
Effective area Weight
(mm²)
g
2.8
2.8
6.5
6.5
6.5
14
21
24
22
34
5
10
10
11
18
16
24
43
47
40
79
87
85
∗ Reference dimension after screwing into NPT threads.
Note: 1in = 25.4mm
18mm2 = 1Cv
1g = 0.0353oz
®
4
Series AKH/AKB
Check Valve with One-Touch Fitting
Dimensions (mm)
1in=25.4mm
Bushing Type: AKB
Millimeter Size
Connection thread size R
(a)
(b)
Connection thread size (a)
A
H
1/8
1/4
3/8
1/2
1/8
1/4
3/8
1/2
Model
H
L
A∗
Effective area
(mm²)
Weight
g
AKB01-01S
AKB02-02S
AKB03-03S
AKB04-04S
14
17
22
24
23.7
39.8
45.2
56.2
19.7
33.8
38.7
48.2
6.5
14
24
34
18
44
86
113
∗ Reference dimension after screwing into R threads.
L
Inch Size
Connection thread size NPT
(b)
(a)
1/8
1/8
1/4
1/4
3/8
3/8
1/2
1/2
Connection thread size (b)
Model
H
L
AKB01-N01S
AKB02-N02S
AKB03-N03S
AKB04-N04S
14.29
17.46
22.23
23.81
24.2
40
44.9
55.5
A∗
20.2
34
38.4
47.5
Effective area
(mm²)
Weight
g
6.5
14
24
34
18
44
86
113
∗ Reference dimension after screwing into NPT threads.
Note: 1in = 25.4mm
8mm2 = 1Cv
1g = 0.0353oz
®
5
Series AKH/AKB
Check Valve with One-Touch Fitting
Construction
Straight type: AKH
ø4, ø6
ø5/32, ø1/4
ø8, ø10, ø12
ø5/16, ø3/8, ø1/2
Parts list
No.
Description
Material
1
Body
PBT
2
Valve
NBR, Aluminum alloy
3
Spring
Stainless steel
4
Spacer
Brass
5
Cassette
6
Seal
Note
Electroless nickel plated
–
NBR
Male Connector Type: AKH
M5 type
U10/32
ø4, ø6
ø8 x R 1/8
ø5/32, ø1/4
ø5/16 x NPT 1/8
Free flow
Fitting
↑
Male thread
ø8, ø10, ø12
ø5/16, ø3/8, ø1/2
Parts list
Material
Note
1
Body
Brass
Electroless nickel plated
2
Valve
NBR, Aluminum alloy
3
Spring
Stainless steel
4
Spacer
Brass
5
Stopper
Stainless steel
6
O-ring
7
Cassette
8
Seal
9
Gasket
No.
Free flow
Fitting
↓
Male thread
Description
Electroless nickel plated
NBR
–
NBR
Stainless steel + NBR
Bushing Type: AKB
R 1/8
NPT 1/8
R 1/4, 3/8, 1/2
NPT 1/4, 3/8, 1/2
Auto Switch
D-B7/B8
D-G7/K7
Free flow
Female thread
↑
Male thread
Parts list
Free flow
Female thread
↓
Male thread
®
6
Material
Note
1
Body
Brass
Electroless nickel plated
2
Valve
NBR, Aluminum alloy
3
Spring
Stainless steel
4
Spacer
Brass
5
Stopper
Stainless steel
6
O-ring
No.
Description
NBR
Electroless nickel plated
Series AKH/AKB
Check Valve with One-Touch Fitting
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by labels of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1),
JIS B 8370 Note 2) and other safety practices.
Caution : Operator error could result in injury or equipment damage.
Warning : Operator error could result in serious injury or loss of life.
Danger :
In extreme conditions, there is a possible result of serious injury or loss of life.
Note 1) ISO 4414: Pneumatic fluid power -- Recommendations for the application of equipment to transmission and control
systems.
Note 2) JIS B 8370: General Rules for Pneumatic Systems
Warning
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of
safe locked-out control positions.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod,
etc. (Bleed air into the system gradually to create back-pressure.)
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical
equipment, food and beverages, recreation equipment, emergency stop circuits, press applications, or
safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.
®
7
Series AKH/AKB
Check Valve with One-Touch Fitting
Safety Instructions
Air Supply
Selection
Warning
Warning
1. Confirm the specifications.
The products appearing in this catalog are designed for use
only in compressed air systems (including vacuum). Do not use
outside the specified ranges of pressure, temperature, etc., as
this may cause damage or faulty operation. (Refer to specifications.)
Consult with SMC if fluids other than compressed air (including
vacuum) are to be used.
Mounting
Warning
1. Read the instruction manual carefully.
The product should be mounted and operated with a good
understanding of its contents. Also, keep the manual where it
can be easily referred to at any time.
2. Ensure space for maintenance.
Ensure the necessary space for maintenance activities.
3. Strictly observe the fastening of screws and
fastening torque.
When mounting, fasten screws with the recommended torque.
Piping
Caution
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out
with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.
2. Wrapping of sealing tape
When screwing together pipes and fittings, etc., be certain that
chips from the pipe threads and sealing material do not get
inside the piping.
Further, when sealing tape is used, leave 1.5 to 2 thread ridges
exposed at the end of the threads.
®
8
1. Types of fluid
This product is designed for use with compressed air. Consult
with SMC if a different fluid is to be used.
2. When there is a large amount of drainage
Pressurized air containing a large amount of drainage may
cause the malfunction of pneumatic equipment. An air dryer or
Drain Catch should be installed upstream from filters.
3. Drainage removal
If the air filter drains are not flushed regularly, the drainage will
flow downstream and this may lead to the malfunction of pneumatic equipment.
In cases where the management of drain flushing will be difficult, the use of filters with automatic drains is recommended.
For details on the qualities of compressed air mentioned
above, refer to SMC's "Compressed Air Cleaning Systems”
catalog.
4. Types of air
Do not use compressed air containing chemicals, synthetic oil
which includes organic solvents, salt, corrosive gases, etc., as
this may cause damage or faulty malfunction.
Check Valve with One-Touch Fitting
Series AKH/AKB
Safety Instructions
Operating Environment
Warning
1. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea
water, fresh water or water vapor, or where
there will be contact with the same.
2. In locations which receive direct sunlight, the
sunlight should be blocked .
3. Do not operate in locations where vibration or
impact occurs.
4. Do not operate in a location near a heat
source where radiated heat will be received.
Maintenance
Warning
1. Maintenance should be performed in accordance with procedures in the instruction manual.
Improper handling may cause damage or malfunction of equipment or machinery.
2. Maintenance operations
Improper handling of compressed air is dangerous. Therefore,
in addition to observing the product specifications, replacement
of elements and other maintenance activities should be performed by personnel having sufficient knowledge and experience pertaining to pneumatic equipment.
3. Drain flushing
Drainage should be flushed from air filter and other drains on a
regular basis. (Refer to specifications.)
4. Pre-maintenance inspection
When removing this product, turn off the electric power, and be
certain to shut off the supply pressure and exhaust the compressed air in the system. Proceed only after confirming that all
pressure has been released to the atmosphere.
5. Post maintenance inspection
After installation, repair or reconstruction, reconnect compressed air and electric power, and then perform inspections
for proper operation and air leakage. If the sound of air leakage
can be heard, or if the equipment does not operate properly,
stop operation and confirm that it is mounted correctly.
6. Disassembly and alteration prohibited
Do not disassemble the unit or make any alterations to it.
®
9
Series AKH/AKB
Check Valve with One-Touch Fitting
Safety Instructions
Mounting
Selection
Warning
Caution
1. Cannot be used as a check valve when zero
leakage is required.
1. Confirm the model and size, etc. before
mounting.
A certain amount of leakage is allowed in the product's specifications.
Also, confirm that the product has no scratches, gouges or
cracks, etc.
2. Confirm the flow direction of a check valve
when mounting.
Caution
1. Do not use in a location where connection
threads or tube connecting sections will slide
or turn.
2. Use tubing within its minimum bend radius.
Using at less than the minimum bend radius can cause breaking or flattening of the tubing.
3. Do not use for gas, gas fuels and refrigerants,
etc., which are combustible, explosive or poisonous.
4. Confirm whether PTFE can be used.
PTFE (tetrafluoroethylene resin) powder is contained in the
sealing materials. Confirm that this will not cause operating
problems.
Operating Environment
Warning
1. Do not use in locations where static electric
charges will be a problem.
This can cause malfunction or failure of the system.
2. Except for the bushing type: AKB, do not use
in locations where spatter is generated.
Confirm the free flow direction with the JIS symbol which is displayed on the body.
3. When connecting tubing, make allowances
for changes in the length of the tubing, etc.
due to pressure.
4. Do not allow tubing and fittings to be subjected to distortion, twisting, pulling or
moment loads, etc. This can cause damage
to fittings, and crushing, bursting or disconnection of tubing, etc.
5. Do not allow tubing to be worn, twisted or
scratched. This can cause crushing, bursting or disconnection of the tubing, etc.
6. When connecting piping and fittings, etc., be
careful that chips from the pipe threads and
sealing material do not get inside. Also, when
sealing tape is used, leave about 2 thread
ridges uncovered at the end of the pipe.
There is a danger of fire occuring if spatter sticks to synthetic
resin parts.
3. Except for the bushing type: AKB, do not use
in environments where there will be direct
contact with liquids such as cutting oil, lubricating oil or coolant oil.
Winding direction
Ex
po
se
ab
ou
t2
Sealing tape
thr
ea
ds
Contact SMC regarding operation in this kind of environment.
Maintenance
Caution
1. Check for the following during regular maintenance, and replace components as necessary.
a) Scratches, gouges, abrasion, corrosion
b) Air leakage
c) Twisting, flattening or distortion of tubing
d) Hardening, deterioration or softness of tubing
2. Do not repair or patch the replaced tubing or
fittings for reuse.
®
10
7. When connecting taper pipe threads, tighten
the wrench flats on the body with a suitable
wrench.
Damage can be caused if any other area is used.
Series AKH/AKB
Check Valve with One-Touch Fitting
Safety Instructions
Precautions on Other Tube Brands
Caution
Tightening Torque
Caution
1. When using other than SMC brand tubes,
confirm that the following specifications are
satisfied with respect to the outside diameter
tolerance of the tube.
1. The proper torque for connecting pipe fittings is shown in the table below. As a rule,
this is equivalent to 2 or 3 turns with a tool
after tightening by hand.
1) Nylon tube
within ±0.1mm
2) Soft nylon tube
within ±0.1mm
3) Polyurethane tube within +0.15mm
within – 0.2mm
Do not use tubes which do not meet these outside diameter tolerances. It may not be possible to connect them, or they may
cause other trouble, such as air leakage or the tube pulling out
after connection.
Be careful of damage due to over tightening. When using miniature pipe fittings, tighten by an additional 1/4 turn after hand
tightening. Further, in cases such as a universal elbow or universal tee which have gaskets in 2 locations, the additional
tightening is doubled to 1/2 turn.
Precautions for One-Touch Fittings
Male thread Proper tightening torque (N⋅m)
M5
10/32-UNF 1/6 turn after hand tightening
7 to 9
1/8
12 to 14
1/4
22 to 24
3/8
28 to 30
1/2
Caution
Attaching and Detaching Tubes to One-Touch
Fittings
1. Attaching of tube
Take a tube having no flaws on its periphery and cut it off at a
right angle. When cutting the tube, use tube cutters TK-1, 2 or
3. Do not use pinchers, nippers or scissors, etc. The tube might
be cut diagonally or flattened, making installation impossible or
causing problems such as disconnection of the tube after
installation or air leakage. Allow some extra length in the tube.
Grasp the tube and push it in slowly, inserting it securely all the
way into the fitting.
After inserting the tube, pull on it lightly to confirm that it will not
come out. If it is not installed securely all the way into the fitting,
this can cause problems such as air leakage or the tube pulling
out.
2. Detaching of tube
Push in the release bushing sufficiently, and push the collar
equally at the same time.
Pull out the tube while holding down the release bushing so
that it does not come out. If the release bushing is not pressed
down sufficiently, there will be increased bite on the tube and it
will become more difficult to pull it out.
When the removed tube is to be used again, using the chewed
portion of the tube as it is can cause problems such as air leakage or difficulty in removing the tube.
®
11
®
World Wide
Support...
North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621)
SMC Pneumatics Inc. (Atlanta)
1440 Lakes Parkway, Suite 600
Lawrenceville, GA 30043
Tel: (770) 624-1940
FAX: (770) 624-1943
SMC Pneumatics Inc. (Cleveland)
2305 East Aurora Rd., Unit A-3
Twinsburg, OH 44087
Tel: (330) 963-2727
FAX: (330) 963-2730
SMC Pneumatics Inc. (Milwaukee)
16850 W. Victor Road
New Berlin, WI 53151
Tel: (262) 827-0080
FAX: (262) 827-0092
SMC Pneumatics Inc. (Richmond)
5377 Glen Alden Drive
Richmond, VA 23231
Tel: (804) 222-2762
FAX: (804) 222-5221
SMC Pneumatics Inc. (Austin)
9101 Wall Street, Suite 1030
Austin, TX 78754
Tel: (512) 926-2646
FAX: (512) 926-7055
SMC Pneumatics Inc. (Columbus)
3687 Corporate Drive
Columbus, OH 43231
Tel: (614) 895-9765
FAX: (614) 895-9780
SMC Pneumatics Inc. (Mnpls.)
990 Lone Oak Road, Suite 162
Eagan, MN 55121
Tel: (651) 688-3490
FAX: (651) 688-9013
SMC Pneumatics Inc. (Rochester)
245 Summit Point Drive
Henrietta, NY 14467
Tel: (716) 321-1300
FAX: (716) 321-1865
SMC Pneumatics Inc. (Boston)
Zero Centennial Drive
Peabody, MA 01960
Tel: (978) 326-3600
Fax: (978) 326-3700
SMC Pneumatics Inc. (Dallas)
12801 N. Stemmons Frwy, Ste. 815
Dallas, TX 75234
Tel: (972) 406-0082
FAX: (972) 406-9904
SMC Pneumatics Inc. (Nashville)
5000 Linbar Drive, Suite 297
Nashville, TN 37211
Tel: (615) 331-0020
FAX: (615) 331-9950
SMC Pneumatics Inc. (S.F.)
85 Nicholson Lane
San Jose, CA 95134
Tel: (408) 943-9600
FAX: (408) 943-9111
SMC Pneumatics Inc. (Charlotte)
5029-B West W.T. Harris Blvd.
Charlotte, NC 28269
Tel: (704) 597-9292
FAX: (704) 596-9561
SMC Pneumatics Inc. (Detroit)
2990 Technology Drive
Rochester Hills, MI 48309
Tel: (248) 299-0202
FAX: (248) 293-3333
SMC Pneumatics Inc. (Newark)
3434 US Hwy. 22 West, Ste. 110
Somerville, NJ 08876
Tel: (908) 253-3241
FAX: (908) 253-3452
SMC Pneumatics Inc. (St. Louis)
4130 Rider Trail North
Earth City, MO 63045
Tel: (314) 209-0080
FAX: (314) 209-0085
SMC Pneumatics Inc. (Chicago)
27725 Diehl Road
Warrenville, IL 60555
Tel: (630) 393-0080
FAX: (630) 393-0084
SMC Pneumatics Inc. (Houston)
9001 Jameel, Suite 180
Houston, TX 77040
Tel: (713) 460-0762
FAX: (713) 460-1510
SMC Pneumatics Inc. (Phoenix)
2001 W. Melinda Lane
Phoenix, AZ 85027
Tel: (623) 492-0908
FAX: (623) 492-9493
SMC Pneumatics Inc. (Tampa)
8507-H Benjamin Road
Tampa, FL 33634
Tel: (813) 243-8350
FAX: (813) 243-8621
SMC Pneumatics Inc. (Cincinnati)
4598 Olympic Blvd.
Erlanger, KY 41018
Tel: (606) 647-5600
FAX: (606) 647-5609
SMC Pneumatics Inc. (L.A.)
14191 Myford Road
Tustin, CA 92780
Tel: (714) 669-1701
FAX: (714) 669-1715
SMC Pneumatics Inc. (Portland)
14107 N.E. Airport Way
Portland, OR 97230
Tel: (503) 252-9299
FAX: (503) 252-9253
SMC Pneumatics Inc. (Tulsa)
10203 A East 61st Street
Tulsa, OK 74146
Tel: (918) 252-7820
FAX: (918) 252-9511
Europe
ENGLAND
SMC Pneumatics (U.K.) Ltd.
GERMANY
SMC Pneumatik GmbH
ITALY
SMC Italia SpA
FRANCE
SMC Pneumatique SA
HOLLAND
SMC Controls BV
SWEDEN
SMC Pneumatics Sweden AB
SWITZERLAND
SMC Pneumatik AG
AUSTRIA
SMC Pneumatik GmbH
SPAIN
~ S.A.
SMC Espana,
IRELAND
SMC Pneumatics (Ireland) Ltd.
Asia
JAPAN
SMC Corporation
KOREA
SMC Pneumatics Korea Co., Ltd.
CHINA
SMC (China) Co., Ltd.
HONG KONG
SMC Pneumatics (Hong Kong) Ltd.
SINGAPORE
SMC Pneumatics (S.E.A.) Pte. Ltd.
PHILIPPINES
SMC Pneumatics (Philippines), Inc.
MALAYSIA
SMC Pneumatics (S.E.A.) Sdn. Bhd.
TAIWAN
SMC Pneumatics (Taiwan) Co., Ltd.
THAILAND
SMC Thailand Ltd.
INDIA
SMC Pneumatics (India) Pvt., Ltd.
North America
CANADA
SMC Pneumatics (Canada) Ltd.
MEXICO
SMC Pneumatics (Mexico) S.A. de C.V.
South America
ARGENTINA
SMC Argentina S.A.
CHILE
SMC Pneumatics (Chile) Ltda.
Oceania
AUSTRALIA
SMC Pneumatics (Australia) Pty. Ltd.
NEW ZEALAND
SMC Pneumatics (N.Z.) Ltd.
SMC offers the same quality and engineering expertise in many other pneumatic components
Valves
Directional Control Valves
Manual Valves
Mufflers
Exhaust Cleaners
Quick Exhaust Valves
Valves
Proportional Valves
Mechanical Valves
Miniature Valves
Fluid Valves
Cylinders/Actuators
Compact Cylinders
Miniature Cylinders
Rodless Cylinders
Rotary Actuators
Pneumatic Grippers
Vacuum
Vacuum Ejectors
Vacuum Accessories
Instrumentation
Pneumatic Positioners
Pneumatic Transducers
SMC Pneumatics Inc.
P.O. Box 26640, Indianapolis, IN 46226
Tel: (317) 899-4440 • FAX: (317) 899-3102
© 1978-2000 SMC Pneumatics, Inc. All Rights Reserved.
April 2000
Air Preparation Equipment
Filters-Regulators-Lubricators
Coalescing Filters
Micro Mist Separators
Fittings
Air Fittings

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement