CyberData 011306 InformaCast® Enabled Indoor Intercom - Flush Mount Operations Guide

Add to my manuals
105 Pages

advertisement

CyberData 011306 InformaCast® Enabled Indoor Intercom - Flush Mount Operations Guide | Manualzz
The IP Endpoint Company

Singlewire InformaCast-enabled
VoIP Flush-Mount Indoor Intercom
Operations Guide
Part #011306
Document Part #930939G
for Firmware Version 11.4.8
CyberData Corporation
3 Justin Court
Monterey, CA 93940
(831) 373-2601
VoIP Flush Mount Indoor Intercom Operations Guide 930939G
Part # 011306
COPYRIGHT NOTICE:
© 2015, CyberData Corporation, ALL RIGHTS RESERVED.
This manual and related materials are the copyrighted property of CyberData Corporation. No part of
this manual or related materials may be reproduced or transmitted, in any form or by any means
(except for internal use by licensed customers), without prior express written permission of
CyberData Corporation. This manual, and the products, software, firmware, and/or hardware
described in this manual are the property of CyberData Corporation, provided under the terms of an
agreement between CyberData Corporation and recipient of this manual, and their use is subject to
that agreement and its terms.
DISCLAIMER: Except as expressly and specifically stated in a written agreement executed by
CyberData Corporation, CyberData Corporation makes no representation or warranty, express or
implied, including any warranty or merchantability or fitness for any purpose, with respect to this
manual or the products, software, firmware, and/or hardware described herein, and CyberData
Corporation assumes no liability for damages or claims resulting from any use of this manual or such
products, software, firmware, and/or hardware. CyberData Corporation reserves the right to make
changes, without notice, to this manual and to any such product, software, firmware, and/or
hardware.
OPEN SOURCE STATEMENT: Certain software components included in CyberData products are
subject to the GNU General Public License (GPL) and Lesser GNU General Public License (LGPL)
“open source” or “free software” licenses. Some of this Open Source Software may be owned by third
parties. Open Source Software is not subject to the terms and conditions of the CyberData
COPYRIGHT NOTICE or software licenses. Your right to copy, modify, and distribute any Open
Source Software is determined by the terms of the GPL, LGPL, or third party, according to who
licenses that software.
Software or firmware developed by CyberData that is unrelated to Open Source Software is
copyrighted by CyberData, subject to the terms of CyberData licenses, and may not be copied,
modified, reverse-engineered, or otherwise altered without explicit written permission from
CyberData Corporation.
TRADEMARK NOTICE: CyberData Corporation and the CyberData Corporation logos are
trademarks of CyberData Corporation. Other product names, trademarks, and service marks may be
the trademarks or registered trademarks of their respective owners.
Technical Support 

The IP Endpoint Company The fastest way to get technical support for your VoIP product is to
submit a VoIP Technical Support form at the following website:
http://support.cyberdata.net/

Phone: (831) 373-2601, Ext. 333
Email: [email protected]
Fax: (831) 373-4193
Company and product information is at www.cyberdata.net.
CyberData Corporation
930939G
Operations Guide
Revision Information
Revision 930939G, which corresponds to firmware version 11.4.8, was released on February 20,
2015, and has the following changes:
•
Updates Figure 2-16, "Home Page"
•
Updates Figure 2-35, "Firmware Page"
•
Updates Figure 2-36, "Home Page"
Browsers Supported
The following browsers have been tested against firmware version 11.4.8:
Operations Guide
•
Internet Explorer (version: 10)
•
Firefox (also called Mozilla Firefox) (version: 23.0.1 and 25.0)
•
Chrome (version: 29.0.1547.66 m)
•
Safari (version: 5.1.7)
930939G
CyberData Corporation
Pictorial Alert Icons
General Alert
This pictorial alert indicates a potentially hazardous situation. This alert will be
followed by a hazard level heading and more specific information about the
hazard.
GENERAL ALERT
Ground
This pictorial alert indicates the Earth grounding connection point.
Hazard Levels
Danger: Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury. This is limited to the most extreme situations.
Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
Caution: Indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury. It may also alert users against unsafe practices.
Notice: Indicates a statement of company policy (that is, a safety policy or protection of property).
The safety guidelines for the equipment in this manual do not purport to address all the safety issues
of the equipment. It is the responsibility of the user to establish appropriate safety, ergonomic, and
health practices and determine the applicability of regulatory limitations prior to use. Potential safety
hazards are identified in this manual through the use of words Danger, Warning, and Caution, the
specific hazard type, and pictorial alert icons.
CyberData Corporation
930939G
Operations Guide
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
13. Prior to installation, consult local building and electrical code requirements.
14. WARNING: The VoIP Intercom enclosure is not rated for any AC voltages!
Warning
Electrical Hazard: This product should be installed by a licensed electrician
according to all local electrical and building codes.
GENERAL ALERT
Warning
Electrical Hazard: To prevent injury, this apparatus must be securely attached to
the floor/wall in accordance with the installation instructions.
GENERAL ALERT
Warning
The PoE connector is intended for intra-building connections only and does not
route to the outside plant.
GENERAL ALERT
CyberData Corporation
930939G
Operations Guide
Contents
i
Chapter 1 Product Overview
1
1.1 How to Identify This Product .....................................................................................................1
1.2 Typical System Installation .......................................................................................................2
1.3 Product Features ......................................................................................................................3
1.4 Supported Protocols .................................................................................................................4
1.5 Supported SIP Servers .............................................................................................................4
1.6 Specifications ...........................................................................................................................5
Chapter 2 Installing the VoIP Flush-Mount Indoor Intercom
6
2.1 Parts List ..................................................................................................................................6
2.2 Intercom Components ..............................................................................................................7
2.3 Intercom Setup .........................................................................................................................8
2.3.1 Intercom Connections ....................................................................................................8
2.3.2 Using the On-Board Relay .............................................................................................9
2.3.3 Wiring the Circuit ..........................................................................................................10
2.3.4 Intercom Connectors ....................................................................................................13
2.3.5 Activity and Link LEDs .................................................................................................15
2.3.6 RTFM Button ................................................................................................................16
2.3.7 Adjusting the Intercom Volume .....................................................................................17
2.3.8 Call Button and the Call Button LED ............................................................................18
2.4 Configure the Intercom Parameters ......................................................................................19
2.4.1 Factory Default Settings ...............................................................................................19
2.4.2 Intercom Web Page Navigation ....................................................................................20
2.4.3 Using the Toggle Help Button .......................................................................................21
2.4.4 Log in to the Configuration Home Page .......................................................................23
2.4.5 Configure the Device ....................................................................................................27
2.4.6 Configure the Network Parameters .............................................................................35
2.4.7 Configure the SIP Parameters .....................................................................................38
2.4.8 Configure the Multicast Parameters .............................................................................45
2.4.9 Configure the Sensor Configuration Parameters ..........................................................47
2.4.10 Configure the Audio Configuration Parameters ..........................................................51
2.4.11 Configure the Events Parameters ..............................................................................56
2.4.12 Configure the Door Strike Relay .................................................................................62
2.4.13 Configure the Device (on the DSR page) ...................................................................66
2.4.14 Configure the Autoprovisioning Parameters ...............................................................69
2.5 Upgrade the Firmware and Reboot the Intercom ...................................................................81
2.5.1 Uploading the Firmware ...............................................................................................81
2.5.2 Reboot the Device ........................................................................................................83
2.6 Command Interface ................................................................................................................84
2.6.1 Command Interface Post Commands ..........................................................................84
Appendix A Mounting the Intercom
88
A.1 Mounting Components ...........................................................................................................88
A.2 Dimensions ............................................................................................................................89
A.3 Wall Mounting ........................................................................................................................91
A.4 Ground Cable Installation .......................................................................................................92
Appendix B Setting up a TFTP Server
93
B.1 Set up a TFTP Server ............................................................................................................93
B.1.1 In a LINUX Environment ..............................................................................................93
B.1.2 In a Windows Environment .........................................................................................93
Appendix C Troubleshooting/Technical Support
94
C.1 Frequently Asked Questions (FAQ) ........................................................................................94
C.2 Documentation .......................................................................................................................94
C.3 Contact Information ................................................................................................................95
C.4 Warranty and RMA Information ..............................................................................................95
Index
Operations Guide
96
930939G
CyberData Corporation
1
1 Product Overview
1.1 How to Identify This Product
To identify the VoIP Flush-Mount Indoor Intercom, look for a model number label similar to the one
shown in 
Figure 1-1. Confirm the following:
•
The model number on the label should be 011306.
•
The serial number on the label should begin with 3061.
Figure 1-1. Model Number Label
WWW.CYBERDATA.NET
INDOOR INTERCOM,FLUSH MOUNT,
PoE, SINGLEWIRE, RoHS
011306B / 021108J
306100001
Serial number begins with 3061
Model number
Operations Guide
930939G
CyberData Corporation
Product Overview 2
Typical System Installation
1.2 Typical System Installation
The Singlewire InformaCast-enabled Voice-over-IP (VoIP) Intercom is a SIP endpoint designed to
provide VoIP phone connectivity in a tamper-proof and secure package.
The following figures illustrate how the VoIP Flush-Mount Indoor Intercom can be installed as part of
a VoIP phone system.
Figure 1-2. Typical Installation—Door Strike Intermediate Relay Module
802.3af Compliant Ethernet Switch
1
2
3
Door Strike Intermediate
Relay Module
Door Strike
4
5
6
Intercom
IP Phone
IP PBX Server
Figure 1-3. Typical Installation—Networked Door Strike Intermediate Relay Module
802.3af Compliant Ethernet Switch
1
Door Strike
Operations Guide
2
Networked Door Strike
Intermediate Relay Module
3
4
Intercom
930939G
5
6
IP Phone
IP PBX Server
CyberData Corporation
Product Overview 3
Product Features
1.3 Product Features
The VoIP Flush Mount Indoor Intercom has the following features:
Operations Guide
•
Compatible with Singlewire InformaCast
•
SingleWire GPI/O input and relay control
•
Singlewire Failover support
•
Supports SRST (Survivable Remote Site Telephony) in a Cisco environment. SRST parameters
are entered statically into the CyberData product's internal webpage.
•
SIP
•
Dual speeds of 10 Mbps and 100 Mbps
•
802.3af compliant
•
2 gang outlet box size
•
Adaptive full duplex voice operation
•
Network/Web management
•
Network adjustable speaker volume adjustment
•
Network configurable door or intrusion sensor settings
•
Network configurable relay activation settings
•
Dial Out Extension supports the addition of comma delimited pauses before sending additional
DTMF tones
•
Network configurable microphone input sensitivity adjustment
•
Network downloadable product firmware
•
Doubles as a paging speaker
•
Call button
•
Call activity indicator (light)
•
Tamper proof design
•
One dry contact relay for auxiliary control
•
Autoprovisioning
•
Configurable audio files
•
Night Ringer
•
Peer-to-peer capable
•
Door closure and tamper alert signal
•
Optional Torx screws with driver kit
•
An active call is indicated by the Call Button LED blinking at one second intervals.
930939G
CyberData Corporation
Product Overview 4
Supported Protocols
1.4 Supported Protocols
The Intercom supports the following protocols:
•
SIP
•
Singlewire InformaCast
•
Singlewire Failover
•
HTTP Web-based configuration
Provides an intuitive user interface for easy system configuration and verification of Intercom
operations.
•
DHCP Client
Dynamically assigns IP addresses in addition to the option to use static addressing.
•
TFTP Client
Facilitates hosting for the Autoprovisioning configuration file.
•
RTP
•
RTP/AVP - Audio Video Profile
•
Facilitates autoprovisioning configuration values on boot
•
Audio Encodings
PCMU (G.711 mu-law)
PCMA (G.711 A-law)
Packet Time 20 ms
1.5 Supported SIP Servers
The following link contains information on how to configure the device for the supported SIP servers:
http://www.cyberdata.net/support/server/index.html
Operations Guide
930939G
CyberData Corporation
Product Overview 5
Specifications
1.6 Specifications
Table 1-1. Specifications
Specifications
Ethernet I/F
10/100 Mbps
Protocol
SIP RFC 3261 Compatible
Power Input
PoE 802.3af compliant or 8 to 12VDC at 1000mAa
Speaker Output
1 Watt Peak Power
On-Board Relay
1A at 30 VDC
Operating Temperature
-10° C to 50° C [14° F to 122° F]
Payload Types
G711, A-law and µ-law
Dimensions
6.840 in. [173.7 mm] Length
2.419 in. [61.4 mm] Width
5.860 in. [148.8 mm] Height
Weight
1.2 lbs. [0.54 kg]
Boxed Weight
2.0 lbs. [0.90 kg]
Part Number
011306
a.
Contacts 1 and 2 on the J3 terminal block are only for powering the device from a non-PoE 12VDC power source as an alternative to
Network PoE power. Use of these contacts for any other purpose will damage the device and void the product warranty.
Operations Guide
930939G
CyberData Corporation
6
2 Installing the VoIP Flush-Mount Indoor
Intercom
2.1 Parts List
Table 2-1 illustrates the VoIP Flush Mount Indoor Intercom parts.
Note
See Appendix A, "Mounting the Intercom" for physical mounting information.
Table 2-1. Parts List
Operations Guide
Quantity
Part Name
1
Intercom Assembly
1
Installation Quick Reference Guide
1
Intercom Mounting Accessory Kit
930939G
Illustration
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 7
Intercom Components
2.2 Intercom Components
Figure 2-1 shows the components of the Intercom.
Figure 2-1. Intercom Components
Speaker Drain Hole
Call Button
See Section 2.3, "Intercom Setup"
for 
information about the functionality
of the Call Button.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 8
Intercom Setup
2.3 Intercom Setup
2.3.1 Intercom Connections
Figure 2-2 shows the pin connections on the J3 (terminal block). This terminal block can accept 
16 AWG gauge wire.
Note
As an alternative to using PoE power, you can supply 8 to 12VDC at 1000mA into the
terminal block.
Caution
GENERAL ALERT
Equipment Hazard: Contacts 1 and 2 on the J3 terminal block are only for
powering the Intercom from a non-PoE 12 VDC power source as an alternative to
Network PoE power. Use of these contacts for any other purpose will damage the
Intercom and void the product warranty.
Figure 2-2. Intercom Connections
Alternate Power Input:
1 = 8 to 12VDC at 1000mA*
2 = Power Ground*
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws
Wire (IN)
3
4
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Reserved for Future Use
8 = Reserved for Future Use
1
8
*Contacts 1 and 2 on the J3 terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
Operations Guide
930939G
J3 Terminal Block
can accept 16 AWG wire
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 9
Intercom Setup
2.3.2 Using the On-Board Relay
Warning
Electrical Hazard: This product should be installed by a licensed electrician
according to all local electrical and building codes.
GENERAL ALERT
Warning
Electrical Hazard: The relay contacts are dry and provided for a normally open
and momentarily closed configuration. Neither the alternate power input nor PoE
power can be used to drive a door strike.
GENERAL ALERT
Warning
Electrical Hazard: The relay does not support AC powered door strikes.
Any use of this relay beyond its normal operating range can cause damage to the
product and is not covered under our warranty policy.
GENERAL ALERT
The device has a built-in relay that can be activated by a web configurable DTMF string that can be
received from a VoIP phone supporting out of band (RFC2833) DTMF as well as a number of other
triggering events. See the Device Configuration Page on the web interface for relay settings.
This relay can be used to trigger low current devices like LED strobes and security camera input
signals as long as the load is not an inductive type and the relay is limited to a maximum of 
1 Amp @ 30 VDC. Inductive loads can cause excessive “hum” and can interfere with or damage the
unit’s electronics.
We highly recommend that inductive load and high current devices use our Door Strike Intermediate
Relay product (CD# 011269) (see Section 2.3.3.2, "Connecting the Door Strike Intermediate Relay
Module").
This relay interface also has a general purpose input port that can be used to monitor an external
switch and generate an event.
For more information on the sensor options, see the Sensor Configuration Page on the web
interface.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 10
Intercom Setup
2.3.3 Wiring the Circuit
2.3.3.1 Devices Less than 1A at 30 VDC
If the power for the device is less than 1A at 30 VDC and is not an inductive load, then see
Figure 2-3 for the wiring diagram.
When configuring with an inductive load, please use an intermediary relay with a High PIV Ultrafast
Switching Diode. We recommend using the CyberData Door Strike Intermediate Relay Module (CD#
011269) (see Section 2.3.3.2, "Connecting the Door Strike Intermediate Relay Module").
Figure 2-3. Wiring Diagram
Pin 3 - Relay Common
Pin 4 - Relay Normally Open Contact
Pin 5 - Sense Input
Pin 6 - Sense Ground
The J3 terminal block can accept 16 AWG stranded wire.
LED Strobe Light
1
1
8
8
+
DC Source
Sense Input
1 A @ 30 VDC
J3 Terminal Block of the CyberData Device
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 11
Intercom Setup
2.3.3.2 Connecting the Door Strike Intermediate Relay Module
For wiring an electronic door strike, we recommend the use of our external Door Strike Intermediate
Relay (CD# 011269).
This product provides an easier method of connecting standard door strikes as well as AC and
higher voltage devices. See Figure 2-4 for the wiring diagram.
Figure 2-4. Wiring Diagram
1
The J3 terminal block can accept 16 AWG stranded wire.
8
J3 Terminal Block
See the Door Strike Intermediate Relay 
Operations Guide for connection specifics.
See Section 2.4.12, "Configure the Door Strike
Relay" for configuration options.
+
DC Source
AC Source
OR
Door Lock
Sense Input
If you have questions about connecting door strikes or setting up the web configurable options,
please contact our support department at the following website:
http://support.cyberdata.net/
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 12
Intercom Setup
2.3.3.3 Connecting the Networked Door Strike Intermediate Relay
For wiring an electronic door strike to work over a network, we recommend the use of our external
Networked Door Strike Intermediate Relay (CD# 011270).
This product provides an easier method of connecting standard door strikes as well as AC and
higher voltage devices. See Figure 2-5 for the wiring diagram.
Figure 2-5. Wiring Diagram
802.3af Compliant Ethernet Switch
+
See the Networked Door Strike Intermediate 
Relay Operations Guide for connection specifics.
AC Source
DC Source
OR
See Section 2.4.12, "Configure the Door Strike
Relay" for configuration options.
Door Lock
CyberData
Device
Sense Input
Aux Button
If you have questions about connecting door strikes or setting up the web configurable options,
please contact our support department at the following website:
http://support.cyberdata.net/
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 13
Intercom Setup
2.3.4 Intercom Connectors
See the following figures and tables to identify the connectors and functions of the Intercom.
Figure 2-6. Connector Locations
J7 J6
J9
J2
J8
J10
JP10
Table 2-2. Connector Functions
Operations Guide
Connector
Function
J2
Call Button LED Interface
J6
Microphone Interface
J7
Speaker Interface
J8
Keypad Interface — Not Used
J9
Auxiliary Strobe Connector — Not Used
J10
Proximity Sensor Interface — Not Used
JP10
Disables the intrusion sensor when installed.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 14
Intercom Setup
Figure 2-7. Connector Locations
JP1
J1
J12
J3
J5
J4
SW1
Table 2-3. Connector Functions
Connector
Function
JP1
Reset jumpera
J1
PoE Network Connection (RJ-45 ethernet)
J3
Terminal Block (see Figure 2-2)
J4
Console Port (Factory Use Only)
J5
JTAG (Factory Use Only)
J12
Reserved (Factory Use Only)
SW1
See Section 2.3.6, "RTFM Button"
a.Do not install a jumper. Momentary short to reset. Permanent installation of a jumper would prevent the board from running all together.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 15
Intercom Setup
2.3.5 Activity and Link LEDs
2.3.5.1 Verifying the Network Connectivity and Data Rate
When you plug in the Ethernet cable or power supply to the Intercom, the following occurs:
•
The square, YELLOW Activity LED blinks when there is network activity (see Figure 2-8).
•
The square, GREEN Link LED above the Ethernet port indicates that the network connection
has been established (see Figure 2-8).
Figure 2-8. Activity and Link LED
Activity
Operations Guide
Link
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 16
Intercom Setup
2.3.6 RTFM Button
When the Intercom is operational and linked to the network, you can use the Reset Test Function
Management (RTFM) button (see SW1 in Figure 2-9) on the Intercom board to announce and
confirm the Intercom’s IP Address and test to see if the audio is working.
Note
You must do these tests prior to final assembly.
Figure 2-9. RTFM Button (SW1)
SW1
2.3.6.1 Announcing the IP Address
To announce a device’s current IP address:
1. Press and release the RTFM button (see SW1 in Figure 2-10) within a five second window.
Note
The device will use DHCP to obtain the new IP address (DHCP-assigned address or default
to 10.10.10.10 if a DHCP server is not present).
Note
Pressing and holding the RTFM button for longer than five seconds will restore the device to
the factory default settings.
Figure 2-10. RTFM Button (SW1)
SW1
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 17
Intercom Setup
2.3.6.2 Restoring the Factory Default Settings
When troubleshooting configuration problems, it is sometimes convenient to restore the device to a
known state.
Note
Each Intercom is delivered with factory set default values.
To restore the factory default settings:
1. Press and hold the RTFM button (see SW1 in Figure 2-11) for more than five seconds.
2. The device announces that it is restoring the factory default settings.
Note
The device will use DHCP to obtain the new IP address (DHCP-assigned address or default
to 10.10.10.10 if a DHCP server is not present).
Figure 2-11. RTFM Button
SW1
2.3.7 Adjusting the Intercom Volume
You can adjust the Intercom volume through the SIP Volume, Multicast Volume, Ring Volume, and
Sensor Volume settings on the Device Configuration Page.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 18
Intercom Setup
2.3.8 Call Button and the Call Button LED
2.3.8.1 Calling with the The Call Button
•
You may initiate a call by pressing the Call button.
•
An active call is indicated by the Call Button LED blinking at one second intervals.
•
The Intercom can automatically answer an incoming call.
•
You can press the Call Button to terminate an active call.
2.3.8.2 Call Button LED Function
•
Upon initial power or reset, the Call Button LED will illuminate.
•
On boot, the Call Button LED will flash ten times a second while setting up the network and
downloading autoprovisioning files.
•
The device “autoprovisions” by default, and the initial process may take several minutes as the
device searches for and downloads updates. The Call Button LED will blink during this process.
During the initial provisioning, or after the factory defaults have been reset, the device may
download firmware twice. The device will blink, remain solid for 10 to 20 seconds, and then
resume blinking. This process will take longer if there are many audio files downloading.
•
When the software has finished initialization, the Call Button LED will blink twice.
•
When a call is established (not just ringing), the Call Button LED will blink.
•
On the Device Configuration Page (see Section 2.4.5, "Configure the Device"), there is an
option called Button Lit When Idle. This option sets the normal state for the indicator LED. The
Call Button LED will still blink during initialization and calls.
•
The Call Button LED flashes briefly at the beginning of RTFM mode.
Figure 2-12. Call Button and Call Button LED
Call Button and
Call Button LED
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 19
Intercom Setup
2.4 Configure the Intercom Parameters
To configure the Intercom online, use a standard web browser.
Configure each Intercom and verify its operation before you mount it. When you are ready to mount
an Intercom, refer to Appendix A, "Mounting the Intercom" for instructions.
2.4.1 Factory Default Settings
All Intercoms are initially configured with the following default IP settings:
When configuring more than one Intercom, attach the Intercoms to the network and configure one at
a time to avoid IP address conflicts.
Table 2-4. Factory Default Settings
Parameter
Factory Default Setting
IP Addressing
DHCP
IP Address
a
10.10.10.10
Web Access Username
admin
Web Access Password
admin
Subnet Maska
255.0.0.0
a
Default Gateway
10.0.0.1
a. Default if there is not a DHCP server present.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 20
Intercom Setup
2.4.2 Intercom Web Page Navigation
Table 2-5 shows the navigation buttons that you will see on every Intercom web page.
Table 2-5. Web Page Navigation
Web Page Item
Description
Link to the Home page.
Link to the Device page.
Link to the Network page.
Link to go to the SIP page.
Link to the Multicast page.
Link to the Sensor page.
Link to the Audiofiles page.
Link to the Events page.
Link to the Door Strike Relay page.
Link to the Autoprovisioning page.
Link to the Firmware page.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 21
Intercom Setup
2.4.3 Using the Toggle Help Button
The Toggle Help button allows you to see a short description of some of the settings on the
webpage. To use the Toggle Help button, do the following:
1. Click on the Toggle Help button that is on the UI webpage. See Figure 2-13 and Figure 2-14.
Figure 2-13. Toggle/Help Button
2. You will see a question mark ( ) appear next to each web page item that has been provided
with a short description by the Help feature. See Figure 2-14.
Figure 2-14. Toggle Help Button and Question Marks
Question mark 
appears next to the
web page items
Toggle Help button
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 22
Intercom Setup
3. Move the mouse pointer to hover over the question mark (
page item will appear. See Figure 2-15.
), and a short description of the web
Figure 2-15. Short Description Provided by the Help Feature
Question mark
Operations Guide
930939G
A short description of the 
web page item will appear
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 23
Intercom Setup
2.4.4 Log in to the Configuration Home Page
1. Open your browser to the Intercom IP address.
Note
If the network does not have access to a DHCP server, the device will default to an IP
address of 10.10.10.10.
Note
Make sure that the PC is on the same IP network as the Intercom.
Note
You may also download CyberData’s VoIP Discovery Utility program which allows you to
easily find and configure the default web address of the CyberData VoIP products. 

CyberData’s VoIP Discovery Utility program is available at the following website address:
http://www.cyberdata.net/support/voip/discovery.html
Note
The Intercom ships in DHCP mode. To get to the Home page, use the discovery utility to
scan for the device on the network and open your browser from there.
2. When prompted, use the following default Web Access Username and Web Access
Password to access the Home Page (Figure 2-16):
Web Access Username: admin
Web Access Password: admin
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 24
Intercom Setup
Figure 2-16. Home Page
CyberData Indoor Intercom
306101456
v11.4.8
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 25
Intercom Setup
3. On the Home page, review the setup details and navigation buttons described in Table 2-6.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-6. Home Page Overview
Web Page Item
Description
Admin Settings
Username
The username to access the web interface. Enter up to 25 characters.
Password
The password to access the web interface. Enter up to 25 characters.
Confirm Password
Confirm the web interface password.
Current Status
Operations Guide
Serial Number
Shows the device serial number.
Mac Address
Shows the device Mac address.
Firmware Version
Shows the current firmware version.
IP Addressing
Shows the current IP addressing setting (DHCP or static).
IP Address
Shows the current IP address.
Subnet Mask
Shows the current subnet mask address.
Default Gateway
Shows the current default gateway address.
DNS Server 1
Shows the current DNS Server 1 address.
DNS Server 2
Shows the current DNS Server 2 address.
SIP Volume
Shows the current SIP volume level.
Multicast Volume
Shows the current Multicast volume level.
Ring Volume
Shows the current Ring volume level.
Sensor Volume
Shows the current Sensor volume level.
Volume Boost
Shows the current Volume Boost level.
Microphone Gain
Shows the current microphone gain level.
SIP Mode
Shows the current status of the SIP mode.
Multicast Mode
Shows the current status of the Multicast mode.
Event Reporting
Shows the current status of the Event Reporting mode.
Nightringer
Shows the current status of the Nightringer mode.
Primary SIP Server
Shows the current status of the Primary SIP Server.
Backup Server 1
Shows the current status of Backup Server 1.
Backup Server 2
Shows the current status of Backup Server 2.
Nightringer Server
Shows the current status of Nightringer Server.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 26
Intercom Setup
Table 2-6. Home Page Overview (continued)
Web Page Item
Description
Singlewire Settings
Boot Time
Shows the boot time.
Current Time
Shows the current time.
IC Servers
Shows the InformaCast server IP addresses.
Configuration File
Shows the configuration file.
B’casts Accepted
Shows the number of B’casts accepted.
B’casts Rejected
Shows the number of B’casts rejected.
B’casts Active
Shows the number of active B’casts.
Import Settings
Use this button to select a configuration file to import.
After selecting a configuration file, click Import to import the
configuration from the selected file. Then, click Save and Reboot to
store changes.
Export Settings
Click Export to export the current configuration to a file.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of some of
the web page items. First click on the Toggle Help button, and you will
see a question mark ( ) appear next to some of the web page items.
Move the mouse pointer to hover over a question mark to see a short
description of a specific web page item.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 27
Intercom Setup
2.4.5 Configure the Device
1. Click the Device menu button to open the Device page. See Figure 2-17.
Figure 2-17. Device Configuration Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 28
Intercom Setup
2. On the Device page, you may enter values for the parameters indicated in Table 2-7.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-7. Device Configuration Parameters
Web Page Item
Description
Volume Settings (0-9)
SIP Volume
Set the speaker volume for a SIP call. A value of 0 will
mute the speaker during SIP calls.
Multicast Volume
Set the speaker volume for multicast audio streams. A
value of 0 will mute the speaker during multicasts.
Ring Volume
Set the ring volume for incoming calls. A value of 0 will
mute the speaker instead of playing the ring tone when
Auto-Answer Incoming Calls is disabled.
Sensor Volume
Set the speaker volume for playing sensor activated audio.
A value of 0 will mute the speaker during sensor activated
audio.
Microphone Gain
Set the microphone gain level.
Volume Boost:
Set the Boost level to increase the volume output of the
speaker. Using Volume Boost may introduce audio clips or
cause the device to drop from full duplex to half duplex
operation.
No Volume Boost
Volume Boost 1
Volume Boost 2
Normal operation of the product can be met with volume
levels 0 through 9. 0 being mute and 9 being the loudest
volume that in a normal arm's length and average
background noise, will enable full duplex operation and
give the best quality of sound output.
Volume Boost 3
The volume boost options increase the output of the
speaker by:
3db for Boost level 1
6db for Boost level 2
9db for Boost level 3
If the user would like a higher output from the speaker, the
Boost settings are available. However, operation in Boost
Mode may overdrive or clip the audio if, for example, the
phone that is connected has a high microphone gain or if
the person has a loud voice talking too close to the
microphone.
The acoustic echo canceller also has a harder time
maintaining full duplex operation when in the Boost
Mode. The product may drop from full duplex operation
into half/duplex mode while in Boost Mode.
Contact CyberData support for additional information if
needed.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 29
Intercom Setup
Table 2-7. Device Configuration Parameters (continued)
Web Page Item
Description
Relay Settings
Activate Relay with DTMF Code
Activates the relay when the DTMF Activation Code is
entered on the phone during a SIP call with the device.
RFC2833 DTMF payload types are supported.
DTMF Activation Code
Activation code used to activate the relay when entered on
a phone during a SIP call with the device. Activate Relay
with DTMF Code must be enabled. Enter up to 25 digits 
Note: While Enable DTMF Push to Talk is enabled, the *,
#, and 0 keys cannot be used in the DTMF activation
code.
DTMF Activation Duration (in seconds)
The length of time (in seconds) during which the relay will
be activated when the DTMF Activation Code is detected.
Enter up to 5 digits.
NOTE: A DTMF activation duration of 0 will toggle the
relay indefinitely or until the activation code is sent again
Play tone during DTMF Activation
When selected, the device will play a tone out of the
speaker upon DTMF relay activation. The tone plays for
the DTMF Activation Duration (in seconds).
Activate Relay During Ring
When selected, the relay will be activated for as long as
the device is ringing. When Auto-Answer Incoming Calls is
enabled, the device will not ring and this option does
nothing.
Activate Relay During Night Ring
When selected, the relay will be activated as long as the
Nightringer extension is ringing.
Activate Relay While Call Active
When selected, the relay will be activated as long as the
SIP call is active.
Activate Relay on Button Press
When selected, the relay will be activated when the Call
button is pressed.
Relay on Button Press Duration
The length of time (in seconds) during which the relay will
be activated when the Call button is pressed. Enter up to 5
digits. A Relay on Button Press Duration value of 0 will
pulse the relay once when the Call button is pressed.
Clock Settings
Operations Guide
Set Time with NTP Server on boot
When selected, the time is set with an external NTP
server when the device restarts.
NTP Server
Use this field to set the address (in IPv4 dotted decimal
notation or as a canonical name) for the NTP Server. This
field can accept canonical names of up to 64 characters in
length.
Posix Timezone String
See Section 2.4.5.1, "Time Zone Strings" for information
about how to use the Posix Timezone String to specify
time zone and daylight savings time where applicable.
Enter up to 63 characters.
Periodically sync time with server
When selected, the time is periodically updated with the
NTP server at the configured interval below.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 30
Intercom Setup
Table 2-7. Device Configuration Parameters (continued)
Web Page Item
Description
Time update period (in hours)
The time interval after which the device will contact the
NTP server to update the time. Enter up to 4 digits.
Current Time
Allows you to input the current time. (6 character limit)
Misc Settings
Device Name
Type the device name. Enter up to 25 characters.
Auto-Answer Incoming Calls
When selected, the device will automatically answer
incoming calls. When Auto-Answer Incoming Calls is
disabled, the device will play a ring tone (corresponds to
Ring Tone on the Audiofiles page) out of the speaker until
someone presses the Call button to answer the call or the
caller disconnects before the call can be answered.
Button Lit When Idle
When selected, the Call button LED is illuminated while
the device is idle (a call is not in progress).
Button Brightness (0-255)
The desired Call button LED brightness level. Acceptable
values are 0-255, where 0 is the dimmest and 255 is the
brightest. Enter up to three digits.
Play Ringback Tone
When selected, the device will play a ringback tone
(corresponds to Ringback Tone on the Audiofiles page)
out of the speaker while placing an outbound call. The
Ringback Tone will play until the call is answered.
Enable Push to Talk
This option is for noisy environments. When enabled, the
microphone will be muted normally. When the Call button
is pressed and held, it will unmute the microphone and
allow the operator to send audio back. Using Push to Talk
prevents the operator from terminating a call by pressing
the Call button. The call must be terminated by the phone
user.
Enable DTMF Push to Talk
This option is for noisy environments. When enabled, in an
active call, the remote phone can force receive only audio
(setting the mic gain to max and muting the speaker) by
pressing the * key.
Pressing the # key will force send only audio (setting the
max speaker volume and muting the mic). Pressing the 0
key will restore full duplex operation with the normal
microphone and speaker volume.
Prevent Call Termination
When this option is enabled, a call cannot be terminated
using the call button.
Disable HTTPS (NOT recommended)
Disables the encrypted connection to the webpage. We do
not recommend disabling HTTPS for security reasons.
Click on the Test Audio button to do an audio test. When
the Test Audio button is pressed, you will hear a voice
message for testing the device audio quality and volume.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 31
Intercom Setup
Table 2-7. Device Configuration Parameters (continued)
Web Page Item
Description
Click on the Test Microphone button to do a microphone
test. When the Test Microphone button is pressed, the
following occurs:
1. The device will immediately start recording 3 seconds of
audio.
2. The device will beep (indicating the end of recording).
3. The device will play back the recorded audio.
Click on the Test Relay button to do a relay test.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description
of some of the web page items. First click on the Toggle
Help button, and you will see a question mark ( ) appear
next to some of the web page items. Move the mouse
pointer to hover over a question mark to see a short
description of a specific web page item.
Note
Operations Guide
You can change the SIP Volume, Multicast Volume, Ring Volume, Sensor Volume, and
Microphone Gain without rebooting the device. You must save and reboot the device for
other changes to take effect.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 32
Intercom Setup
2.4.5.1 Time Zone Strings
The posix time zone string tells the internal date and time utilities how to handle daylight savings
time for different time zones. Table 2-8 shows some common strings.
Table 2-8. Common Time Zone Strings
Time Zone
Time Zone String
US Pacific time
PST8PDT,M3.2.0/2:00:00,M11.1.0/2:00:00
US Mountain time
MST7MDT,M3.2.0/2:00:00,M11.1.0/2:00:00
US Eastern Time
EST5EDT,M3.2.0/2:00:00,M11.1.0/2:00:00
a
Phoenix Arizona
MST7
US Central Time
CST6DST,M3.2.0/2:00:00,M11.1.0/2:00:00
a.Phoenix, Arizona does not use daylight savings time.
Table 2-9 shows a breakdown of the parts that constitute the following time zone string:
●
CST6DST,M3.2.0/2:00:00,M11.1.0/2:00:00
Table 2-9. Time Zone String Parts
Operations Guide
Time Zone String
Part
Meaning
CST6CDT
The time zone offset from GMT and three character identifiers for the time zone.
CST
Central Standard Time
6
The (hour) offset from GMT/UTC
CDT
Central Daylight Time
M3.2.0/2:00:00
The date and time when daylight savings begins.
M3
The third month (March)
.2
The 2nd occurrence of the day (next item) in the month
.0
Sunday
/2:00:00
Time of day to change
M11.1.0/2:00:00
The date and time when daylight savings ends.
M11
The eleventh month (November)
.1
The 1st occurrence of the day (next item) in the month
.0
Sunday
/2:00:00
Time of day to change
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 33
Intercom Setup
Time Zone String
Examples
Table 2-10 has some more examples of time zone strings.
Table 2-10. Time Zone String Examples
Time Zone
Time Zone String
a
Tokyo
IST-9
Berlinb
CET-1MET,M3.5.0/1:00,M10.5.0/1:00
a.Tokyo does not use daylight savings time.
b.For Berlin, daylight savings time starts on the last Sunday in March at
01:00 UTC, and ends on the last Sunday in October at 01:00 UTC, and is one
hour ahead of UTC.
Time Zone Identifier A user-definable three or four character time zone identifier (such as PST, EDT, IST, MUT, etc) is
needed at the beginning of the posix time zone string to properly set the time. However, the specific
letters or numbers used for the time zone identifier are not important and can be any three or four
letter or number combination that is chosen by the user. However, the time zone identifier cannot be
blank.
Figure 2-18. Three or Four Character Time Zone Identifier
You can also use the following URL when a certain time zone applies daylight savings time:
http://www.timeanddate.com/time/dst/2011.html
World GMT Table
Table 2-11 has information about the GMT time in various time zones.
Table 2-11. World GMT Table
Operations Guide
Time Zone
City or Area Zone Crosses
GMT-12
Eniwetok
GMT-11
Samoa
GMT-10
Hawaii
GMT-9
Alaska
GMT-8
PST, Pacific US
GMT-7
MST, Mountain US
GMT-6
CST, Central US
GMT-5
EST, Eastern US
GMT-4
Atlantic, Canada
GMT-3
Brazilia, Buenos Aries
GMT-2
Mid-Atlantic
GMT-1
Cape Verdes
GMT
Greenwich Mean Time, Dublin
GMT+1
Berlin, Rome
GMT+2
Israel, Cairo
GMT+3
Moscow, Kuwait
GMT+4
Abu Dhabi, Muscat
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 34
Intercom Setup
Table 2-11. World GMT Table (continued)
Operations Guide
Time Zone
City or Area Zone Crosses
GMT+5
Islamabad, Karachi
GMT+6
Almaty, Dhaka
GMT+7
Bangkok, Jakarta
GMT+8
Hong Kong, Beijing
GMT+9
Tokyo, Osaka
GMT+10
Sydney, Melbourne, Guam
GMT+11
Magadan, Soloman Is.
GMT+12
Fiji, Wellington, Auckland
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 35
Intercom Setup
2.4.6 Configure the Network Parameters
1. Click the Network menu button to open the Network page (Figure 2-19).
Figure 2-19. Network Configuration Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 36
Intercom Setup
2. On the Network page, enter values for the parameters indicated in Table 2-12.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-12. Network Configuration Parameters
Web Page Item
Description
Stored Network Settings
Addressing Mode
Select either DHCP IP Addressing or Static Addressing by marking
the appropriate radio button. DHCP Addressing mode is enabled on
default and the device will attempt to resolve network addressing with
the local DHCP server upon boot. If DHCP Addressing fails, the
device will revert to the last known IP address or the factory default
address if no prior DHCP lease was established. See Section 2.4.1,
"Factory Default Settings" for factory default settings. Be sure to click
Save and Reboot to store changes when configuring a Static
address.
Hostname
This is the hostname provided by the DHCP server. See the DHCP/
DNS server documentation for more information. Enter up to 64
characters.
IP Address
Enter the Static IPv4 network address in dotted decimal notation.
Subnet Mask
Enter the Subnet Mask in dotted decimal notation.
Default Gateway
Enter the Default Gateway IPv4 address in dotted decimal notation.
DNS Server 1
Enter the primary DNS Server IPv4 address in dotted decimal
notation.
DNS Server 2
Enter the secondary DNS Server IPv4 address in dotted decimal
notation.
DHCP Timeout in seconds
Specify the desired time-out duration (in seconds) that the device will
wait for a response from the DHCP server before reverting back to
the stored static IP address. The stored static IP address may be the
last known IP address or the factory default address if no prior DHCP
lease was established. Enter up to 8 characters. A value of -1 will
retry forever.
VLAN Settings
VLAN ID (0-4095)
Specify the IEEE 802.1Q VLAN ID number. Enter up to 4 digits.
Note: The device supports 802.1Q VLAN tagging support. The
switch port connected to the device will need to be in “trunking mode”
for the VLAN tags to propagate.
Operations Guide
VLAN Priority (0-7)
Specify the IEEE 802.1p VLAN priority level. Enter 1 digit. A value of
0 may cause the VLAN ID tag to be ignored.
Current Network Settings
Shows the current network settings.
IP Address
Shows the current Static IP address.
Subnet Mask
Shows the current Subnet Mask address.
Default Gateway
Shows the current Default Gateway address.
DNS Server 1
Shows the current DNS Server 1 address.
DNS Server 2
Shows the current DNS Server 2 address.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 37
Intercom Setup
Table 2-12. Network Configuration Parameters (continued)
Web Page Item
Description
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of some of
the web page items. First click on the Toggle Help button, and you
will see a question mark ( ) appear next to some of the web page
items. Move the mouse pointer to hover over a question mark to see
a short description of a specific web page item.
Note
Operations Guide
You must click on the Save button and then the Reboot button for the changes to take
effect.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 38
Intercom Setup
2.4.7 Configure the SIP Parameters
1. Click on the SIP menu button to open the SIP page (Figure 2-20).
Figure 2-20. SIP Configuration Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 39
Intercom Setup
2. On the SIP page, enter values for the parameters indicated in Table 2-13.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-13. SIP Configuration Parameters
Web Page Item
Description
SIP Settings
Enable SIP Operation
When enabled, the device will transmit, receive, and process SIP
messages according to the configured SIP settings below.
Register with a SIP Server
When enabled, the device will attempt to register to the configured SIP
Server(s) on this page. To configure the device to send and receive pointto-point SIP calls, enable SIP Operation and disable Register with a SIP
Server (see Section 2.4.7.2, "Point-to-Point Configuration").
Use Cisco SRST
When enabled, the backup servers are handled according to Cisco SRST
(Survivable Remote Site Telephony). It is required for use in clustered
Cisco Unified Communications Manager topologies.
Primary SIP Server
Enter the SIP server address as an IPv4 address in dotted decimal
notation or a fully qualified domain name. This parameter also becomes
the host portion of the SIP-URI for the device's extension on the primary
SIP server. This field can accept entries of up to 255 characters in length.
Primary SIP User ID
Specify the SIP User ID for the Primary SIP Server. This parameter
becomes the user portion of the SIP-URI for the device's extension on the
primary SIP server. Enter up to 64 alphanumeric characters.
Primary SIP Auth ID
Specify the Authenticate ID for the Primary SIP Server. This parameter is
required for SIP registration authentication. Enter up to 64 alphanumeric
characters.
Primary SIP Auth Password
Specify the Authenticate Password for the Primary SIP Server. This
parameter is required for SIP registration authentication. Enter up to 64
alphanumeric characters.
Backup SIP Server 1
Enter the backup SIP server address as an IPv4 address in dotted
decimal notation or a fully qualified domain name. This parameter also
becomes the host portion of the SIP-URI for the device's extension on the
backup SIP server. This field can accept entries of up to 255 characters in
length.
Backup SIP User ID 1
Specify the SIP User ID for the first backup SIP Server. This parameter
becomes the user portion of the SIP-URI for the device's extension on the
first backup SIP server. Enter up to 64 alphanumeric characters.
Backup SIP Auth ID 1
Specify the Authenticate ID for the first backup SIP server. This parameter
is required for SIP registration authentication. Enter up to 64 alphanumeric
characters.
Backup SIP Auth Password 1
Specify the Authenticate Password for the first backup SIP server. This
parameter is required for SIP registration authentication. Enter up to 64
alphanumeric characters.
Backup SIP Server 2
Enter a second backup SIP server address as an IPv4 address in dotted
decimal notation or a fully qualified domain name. This parameter also
becomes the host portion of the SIP-URI for the device's extension on the
second backup SIP server. This field can accept entries of up to 255
characters in length.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 40
Intercom Setup
Table 2-13. SIP Configuration Parameters (continued)
Web Page Item
Description
Backup SIP User ID 2
Specify the SIP User ID for the second backup SIP Server. This parameter
becomes the user portion of the SIP-URI for the device's extension on the
second backup SIP server. Enter up to 64 alphanumeric characters.
Backup SIP Auth ID 2
Specify the Authenticate ID for the second backup SIP server. This
parameter is required for SIP registration authentication. Enter up to 64
alphanumeric characters.
Backup SIP Auth Password 2
Specify the Authenticate Password for the second backup SIP server. This
parameter is required for SIP registration authentication. Enter up to 64
alphanumeric characters.
Remote SIP Port
The Remote SIP Port is the port number the device will use as the
destination port when sending SIP messages. The default Remote SIP
Port is 5060. The supported range is 0-65536. Enter up to 5 digits.
Local SIP Port
The Local SIP Port is the port number the device will use to receive SIP
messages. The default Local SIP Port is 5060. The supported range is 065536. Enter up to 5 digits.
Outbound Proxy
Enter the Outbound Proxy address as an IPv4 address in dotted decimal
notation or a fully qualified domain name (FQDN). When an IP address is
configured, the device will send all SIP messages to this IP address.
When an FQDN is configured, the device will run DNS NAPTR, SRV, and
A queries on the FQDN to resolve an IP address to which it will send all
SIP messages. This field can accept entries of up to 255 characters in
length.
Outbound Proxy Port
The Outbound Proxy Port is port number used as the destination port
when sending SIP messages to the outbound proxy. A value of 0 will
default to 5060. The supported range is 0-65536. Enter up to 5 digits.
Disable rport Discovery
Disabling rport Discovery will prevent the device from including the public
WAN IP address and port number in the contact information that is sent to
the remote SIP servers. This will generally only need to be enabled when
using an SBC or SIP ALG in conjunction with a remote SIP server.
Re-registration Interval (in seconds)
The SIP Re-registration interval (in seconds) is the SIP Registration lease
time, also known as the expiry. The supported range is 30-3600 seconds.
Enter up to 4 digits.
Unregister on Boot
When enabled, the device will send one registration with an expiry of 0 on
boot.
Keep Alive Period
The minimum time in milliseconds between keep-alive packets sent for nat
traversal. A value of 0 will disable keep alive packets.
RTP Settings
RTP Port (even)
Specify the port number used for the RTP stream after establishing a SIP
call. This port number must be an even number and defaults to 10500.
The supported range is 0-65536. Enter up to 5 digits.
Nightringer Settings
Enable Nightringer
Operations Guide
When Nightringer is enabled, the device will attempt to register a second
extension with the SIP server. Any calls made to this extension will play a
ringtone (corresponds to Night Ring on the Audiofiles page). By design,
it is not possible to answer a call to the Nightringer extension.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 41
Intercom Setup
Table 2-13. SIP Configuration Parameters (continued)
Web Page Item
Description
SIP Server
Enter the SIP server address as an IPv4 address in dotted decimal
notation or a fully qualified domain name. This parameter also becomes
the host portion of the SIP-URI for the device's Nightringer extension on
the SIP server. This field can accept entries of up to 255 characters in
length.
Remote SIP Port
The Remote SIP Port is the port number the device will use as the
destination port when sending SIP messages for the Nightringer
extension. The default Remote SIP Port is 5060. The supported range is
0-65536. Enter up to 5 digits.
Local SIP Port
The Local SIP Port is the port number the device will use to receive SIP
messages for the Nightringer extension. This value cannot be the same as
the Local SIP Port for the primary extension. The default Local SIP Port is
5061. The supported range is 0-65536. Enter up to 5 digits.
Outbound Proxy
Enter the Outbound Proxy address as an IPv4 address in dotted decimal
notation or a fully qualified domain name (FQDN). When an IP address is
configured, the device will send all SIP messages to this IP address for the
Nightringer extension. When an FQDN is configured, the device will run
DNS NAPTR, SRV, and A queries on the FQDN to resolve an IP address
to which it will send all SIP messages for the Nightringer extension. This
field can accept entries of up to 255 characters in length.
Outbound Proxy Port
The Outbound Proxy Port is port number used as the destination port
when sending SIP messages to the outbound proxy for the Nightringer
extension. A value of 0 will default to 5060. The supported range is 065536. Enter up to 5 digits.
User ID
Specify the SIP User ID for the SIP server. This parameter becomes the
user portion of the SIP-URI for the device's Nightringer extension. Enter
up to 64 alphanumeric characters.
Authenticate ID
Specify the Authenticate ID for the SIP Server. This parameter is required
for SIP registration authentication. Enter up to 64 alphanumeric
characters.
Authenticate Password
Specify the Authenticate Password for the SIP Server. This parameter is
required for SIP registration authentication. Enter up to 64 alphanumeric
characters.
Re-registration Interval (in seconds)
The SIP Re-registration Interval (in seconds) is the SIP Registration lease
time, also known as the expiry. The supported range is 30-3600 seconds.
Enter up to 4 digits.
Dial Out Settings
Dial Out Extension
Specify the extension the device will call when someone presses the Call
button. Enter up to 64 alphanumeric characters.
Note: For information about dial-out extension strings and DTMF tones,
see Section 2.4.7.1, "Dial Out Extension Strings and DTMF Tones (using
rfc2833)".
Extension ID
A Caller identification string added to outbound calls. Enter up to 64
alphanumeric characters.
Call Disconnection
Terminate Call After Delay
Operations Guide
Automatically terminate an active call after a given delay in seconds. A
value of 0 will disable this function. Enter up to 8 digits.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 42
Intercom Setup
Table 2-13. SIP Configuration Parameters (continued)
Web Page Item
Description
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of some of the
web page items. First click on the Toggle Help button, and you will see a
question mark ( ) appear next to some of the web page items. Move the
mouse pointer to hover over a question mark to see a short description of
a specific web page item.
Note
You must click on the Save button and then the Reboot button for the changes to take
effect.
Note
For specific server configurations, go to the following website address:
http://www.cyberdata.net/support/server/index.html
2.4.7.1 Dial Out Extension Strings and DTMF Tones (using rfc2833)
On the SIP Configuration Page, dial out extensions support the addition of comma delimited
pauses and sending additional DTMF tones (using rfc2833). The first comma will pause three
seconds after a call is first established with a remote device. Subsequent commas will pause for 2
seconds. A pause of one second will be sent after each numerical digit.
Table 2-14. Examples of Dial-Out Extension Strings
Extension String
Resulting Action
302
Dial out extension 302 and establish a call
302,2
Dial out extension 302 and establish a call, wait 3 seconds then send the
DTMF tone '2'
302,25,,,4,,1
Dial out extension 302 and establish a call, wait 3 seconds then send the
DTMF tone '2', send out DTMF tone 5, wait 6 seconds, send out DTMF
tone 4, wait 4 seconds, send out DTMF tone 1
Note
Operations Guide
The maximum number of total characters in the dial-out field is 64.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 43
Intercom Setup
2.4.7.2 Point-to-Point Configuration
When the device is set to not register with a SIP server (see Figure 2-21), it is possible to set the
device to dial out to a single endpoint.
In this case, the dial-out extension should be the IP address of the remote device. The device can
also receive Point-to-Point calls. The delayed DTMF functionality is available in the Point-to-Point
Mode.
Note
Receiving point-to-point SiP calls may not work with all phones.
Figure 2-21. SIP Page Set to Point-to-Point Mode
CyberData Indoor Intercom
Device is set to NOT register with a SiP server
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 44
Intercom Setup
2.4.7.3 Delayed DTMF
On the SIP Configuration page the dial out extension supports the addition of comma delimited
pauses and sending additional DTMF tones (using rfc2833). The first comma will pause three
seconds after a call is first established with a remote device. Subsequent commas will pause for 2
seconds. A pause of one second will be sent after each numerical digit.
Table 2-15. Examples of Dial-Out Extension Strings
Extension String
Resulting Action
302
Dial out extension 302 and establish a call
302,2
Dial out extension 302 and establish a call, wait 3 seconds then send the
DTMF tone '2'
302,25,,,4,,1
Dial out extension 302 and establish a call, wait 3 seconds then send the
DTMF tone '2', send out DTMF tone 5, wait 6 seconds, send out DTMF
tone 4, wait 4 seconds, send out DTMF tone 1
Note
Operations Guide
The maximum number of total characters in the dial-out field is 25.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 45
Intercom Setup
2.4.8 Configure the Multicast Parameters
The Multicast Configuration page allows the device to join up to ten paging zones for receiving ulaw/
alaw encoded RTP audio streams.
A paging zone can consist of one or many CyberData multicast group-enabled products. There is no
limit to how many speakers can be in a given paging zone. Each multicast group is defined by a
multicast address and port number.
Each multicast group is assigned a priority, allowing simultaneously arriving pages to be serviced
based on importance. Multicast groups are compatible with IGMP through version 3. The device
supports simultaneous SIP and Multicast.
1. Click on the Multicast menu button to open the Multicast page. See Figure 2-22.
Figure 2-22. Multicast Configuration Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 46
Intercom Setup
2. On the Multicast page, enter values for the parameters indicated in Table 2-16.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-16. Multicast Configuration Parameters
Web Page Item
Description
Enable Multicast Operation
Enables or disables multicast operation.
Priority
Indicates the priority for the multicast group. Priority 9 is the
highest (emergency streams). 0 is the lowest (background
music). SIP calls are considered priority 4.5. See Section
2.4.8.1, "Assigning Priority" for more details.
Address
Enter the multicast IP Address for this multicast group (15
character limit).
Port
Enter the port number for this multicast group (5 character
limit [range can be from 2000 to 65535]).
Note: The multicast ports have to be even values. The
webpage will enforce this restriction.
Name
Assign a descriptive name for this multicast group (25
character limit).
Beep
When selected, the device will play a beep before multicast
audio is sent.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Note
You must click on the Save button and then the Reboot button for the changes to take
effect.
2.4.8.1 Assigning Priority
The device will prioritize simultaneous audio streams according to their priority in the list.
If both SIP and Multicast is enabled, SIP audio streams are considered priority 4.5. SIP audio will
interrupt multicast streams with priority 0 through 4 and will be interrupted by multicast streams with
priority 5 through 9.
During priority 9 multicast streams, the volume is set to maximum.
Note
Ringtones and
Nightringtones
Operations Guide
SIP calls, multicast streams, ring tones, ringback tones, and nightring tones are all
prioritized.
Ringtones all play at the same priority level. This means that it is possible to have a nightring tone
and a normal ringtone playing at the same time.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 47
Intercom Setup
2.4.9 Configure the Sensor Configuration Parameters
The door sensor (pins 5 and 6) on the header can be used to monitor a door's open or closed state.
There is an option on the Sensor page to trigger on an open or short condition on these pins. The
door sensor alarm will be activated when the Door Open Timeout parameter has been met.
The intrusion sensor is an optical sensor installed on the Intercom board and will be activated when
the Intercom is removed from the case.
Each sensor can trigger up to five different actions:
•
Flash the LED until the sensor is deactivated (roughly 10 times/second)
•
Activate the relay until the sensor is deactivated
•
Loop an audio file out of the Intercom speaker until the sensor is deactivated
•
Call an extension and establish two way audio
•
Call an extension and play a pre-recorded audio file
Note
Calling a preset extension can be set up as a point-to-point call, but currently can't send
delayed DTMF tones.
1. Click Sensor menu button to open the Sensor page (Figure 2-23).
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 48
Intercom Setup
Figure 2-23. Sensor Configuration Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 49
Intercom Setup
2. On the Sensor page, enter values for the parameters indicated in Table 2-17.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-17. Sensor Configuration Parameters
Web Page Item
Description
Door Sensor Settings
Door Sensor Normally Closed
Select the inactive state of the door sensor. The door sensor is
also known as the Sense Input on the device's terminal block.
Door Open Timeout (in seconds)
The time (in seconds) the device will wait before it performs an
action when the on-board door sensor is activated. The action(s)
performed are based on the configured Door Sensor Settings
below. Enter up to 5 digits.
Flash Button LED
When selected, the Call button LED will flash until the on-board
door sensor is deactivated (roughly 10 times/second).
Activate Relay
When selected, the device's on-board relay will be activated until
the on-board door sensor is deactivated.
Play Audio Locally
When selected, the device will loop an audio file out of the
speaker until the door sensor is deactivated.
Make call to extension
When selected, the device will call an extension when the onboard door sensor is activated. Use the Dial Out Extension field
below to specify the extension the device will call.
Dial Out Extension
Specify the extension the device will call when the on-board door
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID
An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Play recorded audio
When selected, the device will call the Dial Out Extension and
play an audio file to the phone answering the SIP call
(corresponds to Door Ajar on the Audiofiles page).
Repeat Sensor Message
The number of times to repeat the audio message through the
local speaker or to the remote endpoint. A value of 0 will repeat
forever. Enter a value from 0-65536.
Intrusion Sensor Settings
Operations Guide
Flash Button LED
When selected, the Call button LED will flash until the intrusion
sensor is deactivated (roughly 10 times/second).
Activate Relay
When selected, the device's on-board relay will be activated until
the intrusion sensor is deactivated.
Play Audio Locally
When selected, the device will loop an audio file out of the
speaker until the intrusion sensor is deactivated.
Make call to extension
When selected, the device will call an extension when the
intrusion sensor is activated. Use the Dial Out Extension field
below to specify the extension the device will call.
Dial Out Extension
Specify the extension the device will call when the intrusion
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID
An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 50
Intercom Setup
Table 2-17. Sensor Configuration Parameters (continued)
Web Page Item
Description
Play recorded audio
When selected, the device will call the Dial Out Extension and
play an audio file (corresponds to Intrusion Sensor Triggered
on the Audiofiles page) to the phone answering the SIP call
when the intrusion sensor is activated.
Repeat Intrusion Message
The number of times to repeat the audio message through the
local speaker or to the remote endpoint. A value of 0 will repeat
forever. Enter a value from 0-65536.
Click the Test Door Sensor button to test the door sensor.
Click the Test Intrusion Sensor button to test the Intrusion
sensor.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of
some of the web page items. First click on the Toggle Help
button, and you will see a question mark ( ) appear next to
some of the web page items. Move the mouse pointer to hover
over a question mark to see a short description of a specific web
page item.
Note
Operations Guide
You must click on the Save button and then the Reboot button for the changes to take
effect.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 51
Intercom Setup
2.4.10 Configure the Audio Configuration Parameters
The Audiofiles page is used to add custom audio to the board. User uploaded audio will take
precedence over the audio files shipped with the Intercom.
1. Click on the Audiofiles menu button to open the Audiofiles page (Figure 2-24).
Figure 2-24. Audiofiles Configuration Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 52
Intercom Setup
Figure 2-25. Audiofiles Page
2. On the Audiofiles page, enter values for the parameters indicated in Table 2-18.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-18. Audiofiles Configuration Parameters
Web Page Item
Description
Audio Files
0-9
The name of the audio configuration option is the same as the spoken audio that plays on
the board (24 character limit).
'0' corresponds to the spoken word “zero.”
'1' corresponds to the spoken word “one.”
'2' corresponds to the spoken word “two.”
'3' corresponds to the spoken word “three.”
'4' corresponds to the spoken word “four.”
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 53
Intercom Setup
Table 2-18. Audiofiles Configuration Parameters (continued)
Web Page Item
Description
0-9
'5' corresponds to the spoken word “five.”
'6' corresponds to the spoken word “six.”
'7' corresponds to the spoken word “seven.”
'8' corresponds to the spoken word “eight.”
'9' corresponds to the spoken word “nine.”
Dot
Corresponds to the spoken word “dot.” (24 character limit)
Audiotest
Corresponds to the message “This is the CyberData IP speaker test message...” (24
character limit)
Page tone
Corresponds to a simple tone used for beep on initialization and beep on page (24 character
limit).
Your IP Address is
Corresponds to the message “Your IP address is...” (24 character limit).
Rebooting
Corresponds to the spoken word “Rebooting” (24 character limit).
Restoring default
Corresponds to the message “Restoring default” (24 character limit).
Ringback tone
This is the ringback tone that plays when calling a remote extension 
(24 character limit).
Ring tone
This is the tone that plays when set to ring when receiving a call 
(24 character limit).
Intrusion Sensor Triggered
Corresponds to the message “Intrusion Sensor Triggered” (24 character limit).
Door Ajar
Corresponds to the message “Door Ajar” (24 character limit).
Night Ring
Specifies the ringtone for nightring. By default this parameter uses the same audio file that is
selected for the Ring Tone parameter.
Click on the Browse button to navigate to and select an audio file.
The Play button will play that audio file.
The Delete button will delete any user uploaded audio and restore the stock audio file.
The Save button will download a new user audio file to the board once you've selected the
file by using the Browse button. The Save button will delete any pre-existing user-uploaded
audio files.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 54
Intercom Setup
2.4.10.1 User-created Audio Files
User created audio files should be saved in the following format:
RIFF (little-endian) data, WAVE audio, Microsoft PCM, 16 bit, mono 8000 Hz
You can use the free utility Audacity to convert audio files into this format. See Figure 2-26 through
Figure 2-28.
Figure 2-26. Audacity 1
Figure 2-27. Audacity 2
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 55
Intercom Setup
When you export an audio file with Audacity, save the output as:
•
WAV (Microsoft) signed 16 bit PCM.
Figure 2-28. WAV (Microsoft) signed 16 bit PCM
WAV (Microsoft) signed 16 bit PCM
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 56
Intercom Setup
2.4.11 Configure the Events Parameters
The Events page specifies a remote server that can be used to receive HTTP POST events when
actions take place on the board.
1. Click on the Events menu button to open the Events page (Figure 2-29).
Figure 2-29. Event Configuration Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 57
Intercom Setup
2. On the Events page, enter values for the parameters indicated in Table 2-19.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-19. Events Configuration Parameters
Web Page Item
Description
Enable Event Generation
The device will send HTTP POST events to the specified remote
server and port number whenever a certain action takes place.
Select an event type below to generate an HTTP POST event.
Events
Enable Button Events
When selected, the device will report Call button presses.
Enable Call Start Events
When selected, the device will report the start of a SIP call.
Enable Call Terminated Events
When selected, the device will report the end of a SIP call.
Enable Relay Activated Events
When selected, the device will report relay activation.
Enable Relay Deactivated Events
When selected, the device will report relay deactivation.
Enable Ring Events
When selected, the device will report when it starts ringing upon an
incoming SIP call. A Ring Event will not be generated when AutoAnswer Incoming Calls is enabled on the Device page.
Enable Night Ring Events
When selected, the device will report when it starts ringing upon an
incoming SIP call to the Nightringer extension. As a reminder, the
Nightringer extension always rings upon an incoming SIP call and it
is not possible to alter this behavior.
Enable Multicast Start Events
When selected, the device will report when the device starts playing
a multicast audio stream.
Enable Multicast Stop Events
When selected, the device will report when the device stops playing
a multicast audio stream.
Enable Power On Events
When selected, the device will report when it boots.
Enable Sensor Events
When selected, the device will report when the on-board sensor is
activated.
Enable Remote Relay Events
When selected, the device will report when the remote relay (DSR)
is activated.
Enable Security Events
When enabled, the device will report when the intrusion sensor is
activated.
Enable 60 Second Heartbeat Events
When enabled, the device will report a Heartbeat event every 60
seconds. SIP registration is not required to generate Heartbeat
events.
Check All
Click on Check All to select all of the events on the page.
Uncheck All
Click on Uncheck All to de-select all of the events on the page.
Event Server
Server IP Address
The IPv4 address of the event server in dotted decimal notation.
Server Port
Specify the event server port number. The supported range is 065536. Enter up to 5 digits.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 58
Intercom Setup
Table 2-19. Events Configuration Parameters(continued)
Web Page Item
Description
Server URL
Generally, the destination URL is the name of the application that
receives the events and the string in the HTTP POST command. It
can be a script used to parse and process the HTTP POST events.
Enter up to 127 characters.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of some
of the web page items. First click on the Toggle Help button, and
you will see a question mark ( ) appear next to some of the web
page items. Move the mouse pointer to hover over a question mark
to see a short description of a specific web page item.
Note
Operations Guide
You must click on the Save button and then the Reboot button for the changes to take
effect.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 59
Intercom Setup
2.4.11.1 Example Packets for Events
The server and port are used to point to the listening server and the 'Remote Event Server URL' is
the destination URL (typically the script running on the remote server that's used to parse and
process the POST events).
Note
The XML is URL-encoded before transmission so the following examples are not completely
accurate.
Here are example packets for every event:
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 197
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>POWERON</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 199
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>HEARTBEAT</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 196
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>BUTTON</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 201
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>CALL_ACTIVE</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 60
Intercom Setup
User-Agent: CyberData/1.0.0
Content-Length: 205
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>CALL_TERMINATED</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 197
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>RINGING</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 234
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>MULTICAST_START</event>
<index>8</index>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 233
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>MULTICAST_STOP</event>
<index>8</index>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 234
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>RELAY_ACTIVATED</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 61
Intercom Setup
User-Agent: CyberData/1.0.0
Content-Length: 234
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>RELAY_DEACTIVATED</event>
</cyberdata>
POST xmlparse_engine HTTP/1.1
Host: 10.0.3.79
User-Agent: CyberData/1.0.0
Content-Length: 234
Content-Type: application/x-www-form-urlencoded
<?xml version="1.0" encoding="ISO-8859-1"?>
<cyberdata NAME='CyberData VoIP Device' MAC='0020f70015b6'>
<event>NIGHTRINGING</event>
</cyberdata>
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 62
Intercom Setup
2.4.12 Configure the Door Strike Relay
The Door Strike Relay (DSR) is a network device designed to control an electronic door strike. The
DSR is meant to be used as a replacement for (or an addition to) the on-board relay. In addition to
being a drop-in 12 Amp relay, the DSR can monitor and record when the door is open or closed.
The DSR can be configured to trigger in the following ways: on the entry of a DTMF code, during
different call events, manually through the web interface, or by using a Windows application.
1. Click on the DSR menu button to open the DSR page (Figure 2-30).
Figure 2-30. DSR Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 63
Intercom Setup
2. On the DSR page, enter values for the parameters indicated in Table 2-20.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-20. DSR Configuration Parameters
Web Page Item
Description
Remote Relay Settings
The settings in this section will activate an associated door
strike relay.
Activate Relay with DTMF Code
Activates the remote relay (DSR) when the DTMF Activation
Code is entered on the phone during a SIP call with the device.
RFC2833 DTMF payload types are supported.
DTMF Activation Code
Activation code used to activate the remote relay (DSR) when
entered on a phone during a SIP call with the device. Activate
Remote Relay with DTMF Code must be enabled. Enter up to
25 digits.
Note: While Enable DTMF Push to Talk is enabled, the *, #, and
0 keys cannot be used in the DTMF activation code.
DTMF Activation Duration (in seconds)
The length of time (in seconds) during which the remote relay
(DSR) will be activated when the DTMF Activation Code is
detected. Enter up to 5 digits.
Activate Remote Relay During Ring
When selected, the remote relay (DSR) will be activated for as
long as the device is ringing. When Auto-Answer Incoming Calls
is enabled, the device will not ring and this option does nothing.
When selected, the network relay will be activated for as long as
the call is active.
Activate Remote Relay During Night Ring
When selected, the remote relay (DSR) will be activated as long
as the Nightringer extension is ringing.
Activate Remote Relay While Call Active
When selected, the remote relay (DSR) will be activated as long
as the call is active.
Activate Remote Relay on Button Press
When selected, the remote relay (DSR) will be activated when
the Call Button is pressed.
Remote Relay on Button Press Duration
(in seconds)
Listen Port for Remote Relay Status

The length of time (in seconds) during which the remote relay
(DSR) will be activated when the Call button is pressed. Enter
up to 5 digits. A Remote Relay on Button Press Duration value
of 0 will pulse the remote relay (DSR) once when the Call button
is pressed.
Specify the port to listen for remote relay (DSR) status packets.
Remote Door Sensor Settings
Door Open Timeout (in seconds)
The time (in seconds) the device will wait before it performs an
action when the remote (DSR) door sensor is activated. The
action(s) performed are based on the configured Remote Door
Sensor Settings below.
Flash Button LED
When selected, the Call button LED will flash until the remote
(DSR) door sensor is deactivated (roughly 10 times/second).
Activate Local Relay
When selected, the device's on-board relay will be activated
until the remote (DSR) door sensor is deactivated.
Play Audio Locally
When selected, the device will loop an audio file out of the
speaker until the remote (DSR) door sensor is deactivated.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 64
Intercom Setup
Table 2-20. DSR Configuration Parameters (continued)
Web Page Item
Description
Make call to extension
When selected, the device will call an extension when the
remote (DSR) door sensor is activated. Use the 'Dial Out
Extension' field below to specify the extension the device will
call.
Play recorded audio
When selected, the device will call the Dial Out Extension and
play an audio file to the phone answering the SIP call
(corresponds to Door Ajar on the Audiofiles page) when the
remote (DSR) door sensor is activated.
Dial Out Extension
Specify the extension the device will call when the remote
(DSR) door sensor is activated. Enter up to 64 alphanumeric
characters.
Dial Out ID
An additional Caller identification string added to outbound
calls. Enter up to 64 alphanumeric characters.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of
some of the web page items. First click on the Toggle Help
button, and you will see a question mark ( ) appear next to
some of the web page items. Move the mouse pointer to hover
over a question mark to see a short description of a specific
web page item.
Discovered Remote Relays
The Discovered Remote Relays section lists all of the
networked door strike relays on the network. To associate your
device with a door strike relay, click on the Associate button.
This action allows the user to configure the door strike relay.
Keep in mind that a device may only be associated with one
door strike relay.
Product Type
Displays the product type of the remote relay.
IP Address
Displays the IP address of the remote relay.
MAC Address
Displays the MAC address of the remote relay.
Serial Number
Displays the serial number of the remote relay.
Name
Displays the name of the remote relay.
Version
Displays the version of the remote relay.
Use this button to search for and find any remote relays that are
available on the network.
Use this button to view the settings of a remote relay that has
been “discovered” after pressing the Discover button.
Use this button to associate the remote relay with the device.
Only one relay may be associated with a device.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 65
Intercom Setup
Table 2-20. DSR Configuration Parameters (continued)
Web Page Item
Description
Relay Status
Note: The Relay Status section and settings (Figure 2-31) only
appear on the webpage when there is an associated door strike
relay.
Door
Shows the status of the door.
Relay
Shows the status of the remote relay.
Click on the Kick Remote Relay button to activate the remote
relay for a specified time. The time is equal to the DTMF
timeout.
Click on the Activate Remote Relay button to activate the
remote relay until the Deactivate Remote Relay button is
pressed.
Click on the Deactivate Remote Relay button to deactivate the
remote relay.
Click on the Refresh button to refresh the web page and
accurately display the status of the remote relay (active/inactive)
and door (open/closed).
Note
You must click on the Save button and then the Reboot button for the changes to take
effect.
Figure 2-31. Relay Status Section
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 66
Intercom Setup
2.4.13 Configure the Device (on the DSR page)
1. Click the View button on the DSR page to open the Configure Device page (Figure 2-32).
Figure 2-32. DSR Page Configure Device Page
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 67
Intercom Setup
2. On the Configure Device page, enter values for the parameters indicated in Table 2-21.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-21. DSR Page Configure Device Parameters
Web Page Item
Description
Serial Number
Displays the serial number of the door strike relay.
MAC Address
Displays the mac address of the door strike relay.
Version
Displays the firmware version of the door strike relay.
Device Name
Displays the name of the door strike relay. The default name is "LOCK,"
followed by the 9 digit ASCII serial number. The maximum name length is
13 characters. The unit will always respond to its default name.
Addressing Mode
Determines whether an IP address will be manually assigned through
Static mode or dynamically assigned through a DHCP server.
IP Address
Displays the IP address of the door strike relay.
Subnet Mask
Displays the subnet mask of the door strike relay.
Default Gateway
Displays the default gateway of the door strike relay.
Command Port
This shows the port on which the door strike relay sends status packets to
the device (defaults to 49999).
Send Events
When enabled, events can be sent to the associated device.
Event IP Address
The IP address of the associated device.
Event Port
This is the port by which the door strike relay receives commands
(defaults to 59999).
Energize Time
This is the number of seconds that the relay will be energized.
DST
Allows you to either enable or disable the Daylight Savings Time feature.
DST Start
Sets the Daylight Savings Time starting time in the following format:
M3.2.0/02:00:00
M3 is the third month (March).
.2 is the second occurrence of the day in the month.
.0 is Sunday.
/02:00:00 is the time.
Note: When the occurrence is set to 5, the final occurrence of the day in
the specified month is used.
DST End
Sets the Daylight Savings Time ending time in the following format:
M11.1.0/02:00:00
M11 is the eleventh month (November).
.1 is the first occurrence of the day in the month.
.0 is Sunday.
/02:00:00 is the time.
Note: When the occurrence is set to 5, the final occurrence of the day in
the specified month is used.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 68
Intercom Setup
Table 2-21. DSR Page Configure Device Parameters (continued)
Web Page Item
Description
Current Time
Sets the current time.
Note: Be sure to save the current time by clicking on the Set Time button.
Encryption
Encryption can either be set to None or AES-256.
Encryption Key
Sets the AES encryption key. If encryption is currently enabled, the
response to this command will be sent using the “old” key. The new key
should be sent as 64 ASCII hexadecimal characters.
Door State
This field displays the current door state and is not configurable.
Relay State
This field displays the current relay state and is not configurable.
Button State
This field displays the current button state and is not configurable.
LED
This field displays the current LED state and is not configurable.
Alarm State
This field displays the current alarm state and is not configurable.
JP4, 6, 9, 10
This shows whether jumpers JP4, JP6, JP9, or JP10 are either enabled or
disabled through the four digit sequence (0000). The 0 turns to 1 for an
enabled jumper. For example, 0011 would mean jumpers JP9 and JP10
are activated, but JP4 and JP9 are not.
Click on the Refresh button to refresh the Device Configuration page.
Click on the Get Log button to get a log of the associated door strike relay
activity. The door strike relay has 128Kb non-volatile storage for log data,
storing an average of 10 days' worth of log data before it is overwritten.
Click on the Clear Log button to clear the log from the door strike relay
Click on the Reboot button to reboot any “discovered” remote relays and
clear any associated devices.
Click on the Set Time button to change the time.
Click on the Save Changes button to save any changes that are made to
the Device Configuration page.
Note: The time setting must be saved by pressing the Set Time button.
Click on the Cancel button to cancel any changes that were made to the
Configure Device page and return to the DSR page.
Click on the Browse button to navigate through your computer and find
firmware files.
Click on the Upgrade button to upgrade the firmware of the door strike
relay.
Note
Operations Guide
You must click on the Save button and then the Reboot button for the changes to take
effect.
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 69
Intercom Setup
2.4.14 Configure the Autoprovisioning Parameters
Autoprovisioning can be used to automatically configure your device. The autoprovisioning file is an
xml file with the device configuration. Values found in this file will override values stored in on-board
memory.
Note
By default, the device will try to set up its configuration with autoprovisioning.
1. Click the Autoprov menu button to open the Autoprovisioning page. See Figure 2-33.
Figure 2-33. Autoprovisioning Page
CyberData Indoor Intercom
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 70
Intercom Setup
2. On the Autoprovisioning page, you may enter values for the parameters indicated in Table 222.
Note
The question mark icon ( ) in the following table shows which web page items will be defined
after the Toggle Help button is pressed.
Table 2-22. Autoprovisioning Configuration Parameters
Web Page Item
Description
Disable Autoprovisioning
Prevent the device from automatically trying to download a
configuration file. See Section 2.4.14.1, "Autoprovisioning" for
more information.
Autoprovisioning Server
Enter the IPv4 address of the provisioning server in dotted
decimal notation.
Autoprovisioning Filename
The autoprovisioning filename is the configuration filename.
The default autoprovisioning filename is in the format of
<mac address>.xml.
Supported filename extensions are .txt, and .xml. The current
filename is denoted by an asterisk at the bottom of the
Autoprovisioning Page. Enter up to 256 characters.
A file may have any name with an xml extension. If a file
name is entered, the device will look for the specified file
name, and only that file.
Use tftp
The device will use TFTP (instead of http) to download
autoprovisioning files.
Username
The username used to authenticate with an autoprovisioning
server. Leave this field blank to disable authentication.
Password
The password used to authenticate with an autoprovisioning
server. Leave this field blank to disable authentication.
Autoprovisioning Autoupdate 
(in minutes)
The reoccurring time (in minutes) the device will wait before
checking for new autoprovisioning files. Enter up to 6 digits. A
value of 0 will disable this option.
Note: To use the auto update options, enable the Set Time
with NTP Server on boot setting on the Device
Configuration Page page (see Table 2-7).
Autoprovision at time (HHMMSS)
The time of day the device will check for a new
autoprovisioning file. The time must be 6 characters in length
and in HHMMSS format. An empty value will disable this
option.
Note: To use the auto update options, enable the Set Time
with NTP Server on boot setting on the Device
Configuration Page page (see Table 2-7).
The idle time (in minutes greater than 10) after which the
device will check for a new autoprovisioning file. Enter up to 6
digits. A value of 0 will disable this option.
Autoprovision when idle
(in minutes > 10)
Note: To use the auto update options, enable the Set Time
with NTP Server on boot setting on the Device
Configuration Page page (see Table 2-7).
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 71
Intercom Setup
Table 2-22. Autoprovisioning Configuration Parameters (continued)
Web Page Item
Description
Click on the Reboot button to reboot the system.
Click on the Toggle Help button to see a short description of
some of the web page items. First click on the Toggle Help
button, and you will see a question mark ( ) appear next to
some of the web page items. Move the mouse pointer to
hover over a question mark to see a short description of a
specific web page item.
Press the Download Template button to create an
autoprovisioning file for the device. See Section 2.4.14.3,
"Download Template Button"
Autoprovisioning log
Note
The autoprovisioning log provides information about the latest
autoprovisioning attempt (i.e. dhcp options and server
accessed and files parsed or not found).
You must click on the Save button and then the Reboot button for the changes to take
effect.
2.4.14.1 Autoprovisioning
On boot, the device will look for an autoprovisioning server configured on the Autoprovisioning Page
or specified as a DHCP option. When it finds a server, it will try to download the following (in order of
preference):
1. The file configured on the autoprovisioning page.
2. A file named according to it's mac address (for example: 0020f7350058.xml).
3. The file 000000cd.xml
The file can be hosted using a standard web server (like apache, IIS, or nginx), and the device can
download over SSL. The file server can be an ipv4 address in dotted decimal notation or a fully
qualified domain name.
By default, the device will get its autoprovisioning server from the DHCP options. See Section
2.4.14.2, "Sample dhcpd.conf" for an example of how to configure dhcpd to offer autoprovisioning
server addresses. If multiple options are set, the device will attempt to download autoprovisioning
files from every server.
The DHCP option determines the protocol used to download the autoprovisioning file. The device
looks for DHCP options in the following order:
1. Option 43 - a FQDN or an IP address to an http server
2. Option 72 - an IP address to an http server
3. Option 150 - an IP address to a tftp server
4. Option 66 - an IP address to a tftp server or if the entry starts with 'http', a FQDN to a http server.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 72
Intercom Setup
You can download an autoprovisioning template file from the Autoprovisioning Page using the
Download Template button (see Table 2-22). This file contains every configuration option that can
be set on the board.
Autoprovisioning files can contain the whole configuration or a subset of this file. The first
autoprovisioning file can also contain links to other autoprovisioning files.
The <MiscSettings> section contains some examples of additional autoprovisioning files:
<MiscSettings>
<DeviceName>CyberData VoIP Intercom</DeviceName>
<!-<AutoprovFile>common.xml</AutoprovFile>-->
<!-<AutoprovFile>sip_reg[macaddress].xml</AutoprovFile>-->
<!-<AutoprovFile>audio[macaddress]</AutoprovFile>-->
<!-<AutoprovFile>device[macaddress].xml</AutoprovFile>-->
</MiscSettings>
After downloading the first autoprovisioning file, the device will step through up to twenty additional
<AutoprovFile> entries and try to download these files from the same server.
When the device finds a filename with the string [macaddress], it will replace this string with the
mac address.
As an example, the user has configured option 43 on their DHCP server to “http://example.com,” and
on their server, they have a file named 0020f7123456.xml (the same as the mac address of the
device).
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 73
Intercom Setup
The file 0020f7123456.xml contains:
<?xml version="1.0" encoding="utf-8" ?>
<specific>
<MiscSettings>
<DeviceName>Newname</DeviceName>
<AutoprovFile>common.xml</AutoprovFile>
<AutoprovFile>sip_reg[macaddress].xml</AutoprovFile>
<AutoprovFile>audio[macaddress]</AutoprovFile>
<AutoprovFile>device.xml</AutoprovFile>
</MiscSettings>
</specific>
1. The device will first set it's name to 'Newname'.
2. It will try to download http://example.com/common.xml.
3. It will try to download http://example.com/sip_reg0020f7123456.xml.
4. It will try to download http://example.com/audio0020f7123456.
5. It will try to download http://example.com/device.xml.
The device is reconfigured every time it downloads a new file so if two files configure the same
option the last one will be the one that is saved.
It is possible to autoprovision autoprovisioning values (for example, to disable autoprovisioning or to
configure a time to check for new files).
Checking for New The device will always check for an autoprovisioning files on boot but it can be configured to also
Autoprovisioning check after a periodic delay, when idle, or at a specified time. When one of these options is set, the
Files after Boot
device will download its autoprovisioning files again, and if it finds any differences from the files it
downloaded on boot, it will force a reboot and reconfigure.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 74
Intercom Setup
The
Autoprovisioning
Filename
The autoprovisioning filename can contain a file, a file path, or a directory.
Table 2-23. Autoprovisioning File Name
Autoprovisioning
Filename
Autoprovisioning
Server
File Downloaded
config.xml
10.0.1.3
10.0.1.3/config.xml
/path/to/config.xml
10.0.1.3
10.0.1.3/path/to/config.xml
subdirectory/path/
10.0.1.3
10.0.1.3/subdirectory/path/0020f7020002.xml
TFTP options may not support subdirectories. If a directory is set in the filename field, firmware and
audio files will also be downloaded from this subdirectory.
If the filename ends with a forward slash “/,” the device will treat it as a subdirectory.
For example:
The autoprovisioning server is set to “https://www.example.com”
The autoprovisioning filename is set to “cyberdata/”
On boot, the device will try to download:
https://www.example.com/cyberdata/0020f7123456.xml
...and if this fails:
https://www.example.com/cyberdata/000000cd.xml
Audio files and firmware files will also add “cyberdata” to the URL before downloading.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 75
Intercom Setup
Autoprovisioning <FirmwareSettings>
Firmware Updates
<FirmwareFile>505-uImage-ceilingspeaker</FirmwareFile>
<FirmwareServer>10.0.1.3</FirmwareServer>
<OutdoorIntercom30>firmware_file_v9.3.0</OutdoorIntercom30>
<OutdoorIntercom31>firmware_file_v10.3.0</OutdoorIntercom31>
<CallButton31>firmware_file_v10.3.0</CallButton31>
</FirmwareSettings>
In the <FirmwareSettings> section, the <FirmwareServer> element can be used to specify a
different server for hosting firmware files. When this element is not available, the device will try to
download the file from the autoprovisioning server.
The device will use the filename to determine when to autoprovision firmware updates. The default
configuration is blank, so the first time you set a value in your autoprovisioning file, it may force a
firmware update even if the firmware version has not changed.
The <FirmwareFile> name can contain path elements (i.e. /path/to/firmware/10.3.0-uImage[device_file_name]).
The device also supports product strings for downloading firmware. If the <FirmwareFile> option is
not set, the device will look for its particular product string for a firmware filename. In this way, a
generic autoprovisioning file can specify unique firmware for a range of products.
The list of valid product strings:
<ProductString>CallButton31</ProductString>
<ProductString>EmergencyIntercom31</ProductString>
<ProductString>EmergencyIntercom31SW</ProductString>
<ProductString>IndoorIntercom31</ProductString>
<ProductString>IndoorIntercom31SW</ProductString>
<ProductString>IndoorKeypad31</ProductString>
<ProductString>IndoorKeypad31SW</ProductString>
<ProductString>OfficeRinger31</ProductString>
<ProductString>OfficeRinger31SW</ProductString>
<ProductString>OutdoorIntercom31</ProductString>
<ProductString>OutdoorIntercom31SW</ProductString>
<ProductString>OutdoorKeypad31</ProductString>
<ProductString>OutdoorKeypad31SW</ProductString>
<ProductString>Strobe31</ProductString>
<ProductString>Strobe31SW</ProductString>
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 76
Intercom Setup
Autoprovisioning
Example 1
Here's a simple example using four autoprovisioning files to configure two devices:
We boot up two devices with mac addresses 00:20:f7:02:00:01 and 00:20:f7:02:00:02 (Device1
and Device2).
The devices are set to use DHCP and that server provides an autoprovisioning server address with
option 43. The address is “https://autoprovtest.server.net.” The files on this server are as follows:
000000cd.xml
<MiscSettings>
<DeviceName>CyberData Autoprovisioned</DeviceName>
<AutoprovFile>sip_common.xml</AutoprovFile>
<AutoprovFile>sip_[macaddress].xml</AutoprovFile>
</MiscSettings>
sip_common.xml
<SIPSettings>
<SIPServer>10.0.0.253</SIPServer>
<RemoteSIPPort>5060</RemoteSIPPort>
</SIPSettings>
sip_0020f7020001.xml
<SIPSettings>
<SIPUserID>198</SIPUserID>
<SIPAuthPassword>ext198</SIPAuthPassword>
<DialoutExtension0>204</DialoutExtension0>
</SIPSettings>
sip_0020f7020002.xml
<SIPSettings>
<SIPUserID>500</SIPUserID>
<SIPAuthPassword>ext500</SIPAuthPassword>
<DialoutExtension0>555</DialoutExtension0>
</SIPSettings>
On boot, Device1 tries to fetch the file 0020f7023614.xml from “https://autoprovtest.server.net”. This
file is not available, so device1 then tries to fetch the file 000000cd.xml. This file exists, and Device1
parses the three elements.
1. Device1 changes its device name to CyberData Autoprovisioned.
2. Device1 finds an AutoprovFile element containing the filename sip_common.xml. The device
downloads sip_common.xml from “https://autoprovtest.server.net,” and imports this
configuration, setting the sip server to 10.0.0.253 and the remote port to 5060.3.
3. Device1 finds another AutoprovFile element containing the filename sip_[macaddress].xml.
The device replaces the [macaddress] with its own mac address value creating
sip_0020f7020001.xml, downloads this file from “https://autoprovtest.server.net,” and imports
this configuration. This sets the user ID to 198, the password to ext198, and the dialout
extension to 204. Device1 is now finished with autoprovisioning.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 77
Intercom Setup
Device2 goes through the same steps by setting its device name to CyberData Autoprovisioned,
its SIP server to 10.0.0.253, and its port to 5060. When Device2 “sees” sip_[macaddress].xml,
Device2 replaces it with its own mac address and downloads sip_0020f7020002.xml from “https://
autoprovtest.server.net.” Device2 sets the SIP User ID to 500, the password to ext500, and the
dialout extension to 555.
Autoprovisioning
Example 2
Here is another example of setting up your autoprovisioning files:
We boot up two devices with mac addresses 00:20:f7:02:00:01 and 00:20:f7:02:00:02 (Device1
and Device2) and boot them on a network with a DHCP server configured with an autoprovisioning
server at 10.0.1.3 on option 150. Our TFTP server has three files:
0020f7020001.xml
<MiscSettings>
<AutoprovFile>common_settings.xml</AutoprovFile>
</MiscSettings>
<SIPSettings>
<SIPUserID>198</SIPUserID>
<SIPAuthPassword>ext198</SIPAuthPassword>
<DialoutExtension0>204</DialoutExtension0>
</SIPSettings>
0020f7020002.xml
<MiscSettings>
<AutoprovFile>common_settings.xml</AutoprovFile>
</MiscSettings>
<SIPSettings>
<SIPUserID>500</SIPUserID>
<SIPAuthPassword>ext500</SIPAuthPassword>
<DialoutExtension0>555</DialoutExtension0>
</SIPSettings>
common_settings.xml
<MiscSettings>
<DeviceName>CyberData Autoprovisioned</DeviceName>
</MiscSettings>
<SIPSettings> <SIPServer>10.0.0.253</SIPServer>
<RemoteSIPPort>5060</RemoteSIPPort>
</SIPSettings>
1. On boot, Device1 downloads 0020f7020001.xml from 10.0.1.3 and imports these values. The SIP
User ID is 198, the password is ext198, and the dialout extension is 204.
2. Device1 then gets the filename common_settings.xml from the AutoprovFile element and
downloads this file from the TFTP server at 10.0.1.3. and imports these settings. The device name is
set to CyberData Autoprovisioned, the SIP server is set to 10.0.0.253, and the port is set to 5060.
Device2 does the same except it downloads 0020f7020002.xml on boot and imports these values
instead. The Sip User ID is 500, password is ext500, and dialout extension is 555. Device2 then
downloads the common_settings.xml file and imports those values. The device name is set to
CyberData Autoprovisioned, the SIP server is set to 10.0.0.253, and the port is set to 5060.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 78
Intercom Setup
XML Files
XML files can contain <AutoprovFile> elements. If multiple DHCP options are specified, the device
will try to download autoprovisioning files from each in turn. The device will only look for
<AutoprovFile> elements in the first file downloaded from each server. You can specify up to 20
<AutoprovFile> elements in the first autoprovisioning file.
There are numerous ways to change an element of the configuration(xml) file. Using sip ext as an
example, the extension can be changed:
Within the device-specific xml, i.e. [macaddress].xml, via the AutoprovFile element:<SIPSettings>/
<SIPExt>
From the device specific xml, a pointer to a sip_common file
From the device specific xml, a pointer to the device specific sip_[macaddress].xml
From the common file, a pointer to sip_common.xml
From the common file, a pointer to the device specific (sip_[macaddress].xml)
Autoprovisioned
Audio Files
Audio files are stored in non-volatile memory and an autoprovisioned audio file will only have to be
downloaded once for each device. Loading many audio files to the device from the web page could
cause it to appear unresponsive. If this happens, wait until the transfer is complete and then refresh
the page.
The device uses the file name to determine when to download a new audio file. This means that if
you used autoprovisioning to upload a file and then changed the contents of this file at the TFTP
server, the device will not recognize that the file has changed (because the file name is the same).
Since audio files are stored in non-volatile memory, if autoprovisioning is disabled after they have
been loaded to the board, the audio file settings will not change. You can force a change to the audio
files on the board by clicking Restore Default on the Audio Configuration page or by changing the
autoprovisioning file with “default” set as the file name.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 79
Intercom Setup
2.4.14.2 Sample dhcpd.conf
#
# Sample configuration file for ISC dhcpd for Debian
#
ddns-update-style none;
option domain-name "voiplab";
option domain-name-servers 10.0.0.252;
option option-150 code 150 = ip-address;
option ntp-servers north-america.pool.ntp.org;
option space VendorInfo;
option VendorInfo.text code 10 = { text };
authoritative;
log-facility local7;
subnet 10.0.0.0 netmask 255.0.0.0 {
max-lease-time 3600;
default-lease-time 3600;
option routers
option subnet-mask
10.0.0.1;
255.0.0.0;
option domain-name
option domain-name-servers
"voiplab";
10.0.0.252;
option time-offset
-8;
# Pacific Standard Time
#
option www-server
99.99.99.99;
#
#
option tftp-server-name
option tftp-server-name
"10.0.1.52";
"http://test.cyberdata.net";
# OPTION 66
# OPTION 66
#
option option-150
10.0.0.252;
# OPTION 150
# These two lines are needed for option 43
#
vendor-option-space VendorInfo;
#
option VendorInfo.text "http://test.cyberdata.net";
# OPTION 72
# OPTION 43
# OPTION 43
range 10.10.0.1 10.10.2.1; }
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 80
Intercom Setup
2.4.14.3 Download Template Button
The Download Template button allows the user to generate, download, edit, and then store an
autoprovisioning template on the server that serves the autoprovisioning files for devices.
To generate an autoprovisioning template directly from the device, complete the following steps:
1. On the Autoprovisioning page, click on the Download Template button.
2. You will see a window prompting you to save a configuration file (.xml) to a location on your
computer (Figure 2-34). The configuration file is the basis for the default configuration settings
for your unit).
3. Choose a location to save the configuration file and click on OK. See Figure 2-34.
Figure 2-34. Configuration File
4. At this point, you can open and edit the autoprovisioning template to change the configuration
settings in the template for the unit.
5. You can then upload the autoprovisioning file to a TFTP or HTTP server where the file can be
loaded onto other devices.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 81
Intercom Setup
2.5 Upgrade the Firmware and Reboot the Intercom
Caution
Equipment Hazard: Devices with a serial number that begins with 3051xxxxx can
only run firmware versions 10.0.0 or later.
GENERAL ALERT
2.5.1 Uploading the Firmware
To upload the firmware from your computer:
1. Retrieve the latest Intercom firmware file from the VoIP Flush-Mount Indoor Intercom
Downloads page at:
http://www.cyberdata.net/products/voip/digitalanalog/singlewireintercomindoorflush/downloads.html
2. Unzip the firmware version file. This file may contain the following:
•
Firmware file
•
Release notes
3. Log in to the Intercom home page as instructed in Section 2.4.4, "Log in to the Configuration
Home Page".
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 82
Intercom Setup
4. Click the Firmware menu button to open the Firmware page. See Figure 2-35.
Caution
GENERAL ALERT
Equipment Hazard: CyberData strongly recommends that you first reboot the
device before attempting to upgrade the firmware of the device. See Section 2.5.2,
"Reboot the Device".
Figure 2-35. Firmware Page
CyberData Indoor Intercom
v11.4.8
5. Click on the Browse button, and then navigate to the location of the firmware file.
6. Select the firmware file.
7. Click on the Upload button.
Note
Do not reboot the device after clicking on the Upload button.
Note
This starts the upgrade process. Once the Intercom has uploaded the file, the Uploading
Firmware countdown page appears, indicating that the firmware is being written to flash.
The Intercom will automatically reboot when the upload is complete. When the countdown
finishes, the Firmware page will refresh. The uploaded firmware filename should be
displayed in the system configuration (indicating successful upload and reboot).
8. Table 2-24 shows the web page items on the Firmware page.
Table 2-24. Firmware Parameters
Web Page Item
Description
Current Firmware Version
Shows the current firmware version.
Use the Browse button to navigate to the location of the
Intercom firmware file that you want to upload.
Click on the Upload button to automatically upload the selected
firmware and reboot the system.
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 83
Intercom Setup
2.5.2 Reboot the Device
To reboot a Intercom, log in to the web page as instructed in Section 2.4.4, "Log in to the
Configuration Home Page".
1. Click on the Reboot button on the Home page (Figure 2-36). A normal restart will occur.
Figure 2-36. Home Page
CyberData Indoor Intercom
306101456
v11.4.8
Reboot
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 84
Intercom Setup
2.6 Command Interface
Some functions on the device can be activated using simple POST commands to the web interface.
The examples in Table 2-25 use the free unix utility, wget commands. However, any program that
can send HTTP POST commands to the device should work.
2.6.1 Command Interface Post Commands
Note
These commands require an authenticated session (a valid username and password to
work).
Table 2-25. Command Interface Post Commands
Device Action
HTTP Post Commanda
Trigger relay (for configured delay)
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
command.cgi" --post-data "test_relay=yes"
Place call to extension (example: extension 130)
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
command.cgi" --post-data "call=130"
Place point-to-point callb 
(example: IP phone address = 10.0.3.72)
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
command.cgi" --post-data "call=10.0.3.72"
Terminate active call
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
command.cgi" --post-data "terminate=yes"
Force reboot
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
command.cgi" --post-data "reboot=yes"
Test Audio button
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
command.cgi" --post-data "test_audio=yes"
Announce IP address
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
command.cgi" --post-data "speak_ip_address=yes"
Play the "0" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_0=yes"
Play the "1" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_1=yes"
Play the "2" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_2=yes"
Play the "3" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_3=yes"
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 85
Intercom Setup
Table 2-25. Command Interface Post Commands (continued)
Device Action
HTTP Post Commanda
Play the "4" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_4=yes"
Play the "5" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_5=yes"
Play the "6" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_6=yes"
Play the "7" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_7=yes"
Play the "8" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_8=yes"
Play the "9" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_9=yes"
Play the "Dot" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_d=yes"
Play the "Audio Test" audio file (from Audio Config)
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_audiotest=yes"
Play the "Page Tone" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_pagetone=yes"
Play the "Your IP Address Is" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_youripaddressis=yes"
Play the "Rebooting" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_rebooting=yes"
Play the "Restoring Default" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_restoringdefault=yes"
Play the "Ringback tone" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_ringback=yes"
Play the "Ring tone" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_ringtone=yes"
Play the "Intrusion Sensor Triggered" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_intrusionsensortriggered=yes"
Play the "Door Ajar" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_doorajar=yes"
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 86
Intercom Setup
Table 2-25. Command Interface Post Commands (continued)
Device Action
HTTP Post Commanda
Play the "Night Ring" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "play_nightring=yes"
Delete the "0" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_0=yes"
Delete the "1" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_1=yes"
Delete the "2" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_2=yes"
Delete the "3" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_3=yes"
Delete the "4" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_4=yes"
Delete the "5" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_5=yes"
Delete the "6" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_6=yes"
Delete the "7" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_7=yes"
Delete the "8" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_8=yes"
Delete the "9" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_9=yes"
Delete the "Audio Test" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_audiotest=yes"
Delete the "Page Tone" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_pagetone=yes"
Delete the "Your IP Address Is" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_youripaddressis=yes"
Delete the "Rebooting" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_rebooting=yes"
Delete the "Restoring Default" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_restoringdefault=yes"
Operations Guide
930939G
CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom 87
Intercom Setup
Table 2-25. Command Interface Post Commands (continued)
Device Action
HTTP Post Commanda
Delete the "Ringback tone" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_ringback=yes"
Delete the "Ring tone" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_ringtone=yes"
Delete the "Intrusion Sensor Triggered" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_intrusionsensortriggered=yes"
Delete the "Door Ajar" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_doorajar=yes"
Delete the "Night Ring" audio file
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
audiofiles.cgi" --post-data "delete_nightring=yes"
Trigger the Door Sensor Test (Sensor Config page)
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
sensor.cgi" --post-data "doortest=yes"
Trigger the Intrusion Sensor Test (Sensor Config page)
wget --user admin --password admin --auth-no-challenge --nocheck-certificate --quiet -O /dev/null "https://10.0.3.71/cgi-bin/
sensor.cgi" --post-data "intrusiontest=yes"
a.Type and enter all of each http POST command on one line.
b. Must be in point-to-point mode see Section 2.4.7.2, "Point-to-Point Configuration"
Operations Guide
930939G
CyberData Corporation
88
Appendix A: Mounting the Intercom
A.1 Mounting Components
Before you mount the Intercom, make sure that you have received all the parts for each Intercom.
Refer to the following tables.
Table A-1. Mounting Components (Part of the Accessory Kit)
Quantity
Part Name
1
T15 Security Pin Torx Key
4
#6 X 3/8-inch,100 Deg.,
Illustration
Flat Head, Self-Tapping Screw
4
#6 X 3/8-inch,100 Deg.,
Flat Head T15 Security Pin Torx
Screw
Operations Guide
930939G
CyberData Corporation
Mounting the Intercom 89
Dimensions
A.2 Dimensions
Figure A-1. Unit Dimensions
5.860 [148.8]
0.170 [4.3]
6.840 [173.7]
Dimensions are in Inches [Millimeter]
2.419 [61.4]
4.800 [121.9]
5.860 [148.8]
Figure A-2. Faceplate Dimensions and Intrusion Sensor Range
Effective Range for
Intrusion Sensor to Function
Affix Reflective Surface Above
Intrusion Sensor
from 3 mm (Minimum)
to 14 mm (Maximum)
0.118 [3.0] Minimum Distance
0.551 [14.0] Maximum Distance
Instrusion
Sensor
J1
4.700 [119.4]
6.840 [173.7]
Dimensions are in Inches [Millimeter]; Projection: Third Angle
Operations Guide
930939G
Ø0.150 [Ø3.8] 82° Countersunk
(4 Places)
CyberData Corporation
90
JP10
0.551 [14.00]
BOTTOM SIDE
Effective Range for
Intrusion Sensor to Function
from 3 mm to 14 mm
Instrusion
Sensor
J10
JP1
4.200 [106.68]
J2
J7
J12
J1
J5
J3
J4
930939G
J8
3.700 [93.98]
TOP SIDE
0.118 [3.00]
ø0.138 [ø3.51]
Fits #6-32 Machine Screw
(4 Places)
1.083 [27.52]
CyberData Corporation
Dimensions
Figure A-3. PCB Dimensions and Intrusion Sensor Range
SW1
J9
J6
2.300 [58.42]
0.501 [12.73]
0.532 [13.53]
Operations Guide
4.200 [106.68]
DIMENSIONS ARE IN INCHES [MILLIMETER]
PROJECTION: THIRD ANGLE PROJECTION
Mounting the Intercom 91
Wall Mounting
A.3 Wall Mounting
Figure A-4 illustrates a wall mounting option for the VoIP Flush-Mount Indoor Intercom.
Figure A-4. Wall Mounting
7 Fold Down all Flagnuts (4 Places)
8 (4Flagnuts
Places)
before Inserting into Wall Cutout
Wire &
3 Ground
Network Cable
Custom
2 Gang Box
Enclosure
(Not Provided)
9 Mounting
Screws
(Phillip Drive)
6.03 inches
[153mm]
5
1
Network Cable
to J1
Wall
Cutout
2
K.O.
9 Mounting
Screws
5.28 inches
[134mm]
(Security
Torx Drive)
Torx Key
6
Intrusion
Sensor
Faceplate
Assembly
Arrow Labels must
Point Upward.
This will Ensure that
the Intrusion Sensor
Functions Properly.
J1
CreateService
Service
Loop
Loop
4 Create
Inside Gang Box
Inside Custom Enclosure
Note: To mount the intercom, use methods
compliant with local electrical codes.
To mount the Intercom:
1. Make a wall cutout as shown in the picture.
2. Use a flat blade screwdriver to remove the knockout (KO) of the gang box.
3. Feed the ground wire (shown in Section A.4, "Ground Cable Installation") and the network cable
from the wall cutout through the knockout hole of the gang box.
4. Create a service loop for both the ground wire and network cable.
5. Plug the network cable into the J1 connector.
6. Make sure that the arrow labels are pointing up. This will ensure that the intrusion sensor
functions properly.
7. Fold down all of the flagnuts, and then insert the gang box into the wall cutout.
Operations Guide
930939G
CyberData Corporation
Mounting the Intercom 92
Ground Cable Installation
8. Tighten the flagnuts with a Phillips screwdriver.
9. Secure the Intercom faceplate assembly to the gang box with either Phillips screws or security
Torx screws.
A.4 Ground Cable Installation
Figure A-5 illustrates how to connect a ground cable to the VoIP Flush-Mount Indoor Intercom.
Figure A-5. Ground Cable Installation
Create Service Loop
inside Gang Box
Knock Out
Nut
#6 Ring Terminal
Star Washer
Ground Wire
(Not Provided)
Ground Lug
Note: To mount the intercom, use methods
compliant with local electrical codes.
Operations Guide
930939G
CyberData Corporation
93
Appendix B: Setting up a TFTP Server
B.1 Set up a TFTP Server
Autoprovisioning requires a TFTP server for hosting the configuration file.
B.1.1 In a LINUX Environment
To set up a TFTP server on LINUX:
1. Create a directory dedicated to the TFTP server, and move the files to be uploaded to that
directory.
2. Run the following command where /tftpboot/ is the path to the directory you created in
Step 1: the directory that contains the files to be uploaded. For example:
in.tftpd -l -s /tftpboot/your_directory_name
B.1.2 In a Windows Environment
You can find several options online for setting up a Windows TFTP server. This example explains
how to use the Solarwinds freeware TFTP server, which you can download from the following
website address:
http://www.cyberdata.net/support/voip/solarwinds.html
To set up a TFTP server on Windows:
1. Install and start the software.
2. Select File/Configure/Security tab/Transmit Only.
3. Make a note of the default directory name, and then move the firmware files to be uploaded to
that directory.
Operations Guide
930939G
CyberData Corporation
94
Appendix C: Troubleshooting/Technical
Support
C.1 Frequently Asked Questions (FAQ)
A list of frequently asked questions (FAQs) are available on the VoIP Flush-Mount Indoor Intercom
product page at:
http://www.cyberdata.net/products/voip/digitalanalog/singlewireintercomindoorflush/faqs.html
Select the support page for your product to see a list of frequently asked questions for the
CyberData product:
C.2 Documentation
The documentation for this product is released in an English language version only. 
You can download PDF copies of CyberData product documentation from the
VoIP Flush-Mount Indoor Intercom product page at:
http://www.cyberdata.net/products/voip/digitalanalog/singlewireintercomindoorflush/docs.html
Operations Guide
930939G
CyberData Corporation
Troubleshooting/Technical Support 95
Contact Information
C.3 Contact Information
Contact
CyberData Corporation
3 Justin Court
Monterey, CA 93940 USA
www.CyberData.net
Phone: 800-CYBERDATA (800-292-3732)
Fax: 831-373-4193
Sales
Sales 831-373-2601 Extension 334
Technical 
Support
The fastest way to get technical support for your VoIP product is to submit a VoIP Technical
Support form at the following website:
http://support.cyberdata.net/
The Support Form initiates a ticket which CyberData uses for tracking customer requests. Most
importantly, the Support Form tells us which PBX system and software version that you are
using, the make and model of the switch, and other important information. This information is
essential for troubleshooting. Please also include as much detail as possible in the Comments
section of the Support Form.
Phone: (831) 373-2601, Ext. 333
Email: [email protected]
Returned
Materials
Authorization
To return the product, contact the Returned Materials Authorization (RMA) department:
Phone: 831-373-2601, Extension 136
Email: [email protected]
When returning a product to CyberData, an approved CyberData RMA number must be printed
on the outside of the original shipping package. Also, RMA numbers require an active VoIP
Technical Support ticket number. A product will not be accepted for return without an approved
RMA number. Send the product, in its original package, to the following address:
CyberData Corporation
3 Justin Court 
Monterey, CA 93940 
Attention: RMA "your RMA number"
RMA Status Form If you need to inquire about the repair status of your product(s), please use the CyberData RMA
Status form at the following website address:
http://support.cyberdata.net/
C.4 Warranty and RMA Information
The most recent warranty and RMA information is available at the following website address:
http://support.cyberdata.net/
Operations Guide
930939G
CyberData Corporation
96
Index
Chrome (web browser) 3
Cisco SRST 39
command interface 84
commands 84
configurable parameters 28, 36, 39, 67
configuration
audio 51
default IP settings 19
door sensor 47
intrusion sensor 47
network 35, 66
SIP 38
using Web interface 19
configuration home page 23
configuration page
configurable parameters 28, 36, 67
contact information 95
contact information for CyberData 95
Current Network Settings 36
current network settings 36
CyberData contact information 95
Numerics
16 AWG gauge wire 8
A
activate local relay (door sensor) 63
activate relay (door sensor) 49
activate relay (intrusion sensor) 49
activity LED 15
address, configuration login 23
alternative power input 5
announcing a device’s IP address 16
audio configuration 51
night ring tone parameter 53
audio configuration page 51
audio encodings 4
audio files, user-created 54
autoprovision at time (HHMMSS) 70
autoprovision when idle (in minutes > 10) 70
autoprovisioning 71
download template button 71
setting up a TFTP server 93
autoprovisioning autoupdate (in minutes) 70
autoprovisioning configuration 69, 70
autoprovisioning filename 70
autoprovisioning server (IP Address) 70
D
default
gateway 19
intercom settings 96
IP address 19
subnet mask 19
username and password 19
web login username and password 23
default gateway 19, 36
default intercom settings 17
default IP settings 19
default login address 23
device configuration 27
device configuration parameters 70
the device configuration page 69
device configuration page 27
device configuration parameters 28
device configuration password
changing for web configuration access 27
DHCP Client 4
dial out extension (door sensor) 49, 64
dial out extension (intrusion sensor) 49
dial out extension strings 42
dial-out extension strings 44
dimensions 5, 89
pcb dimensions and intrusion sensor range 90
unit dimensions—front and side view 89
B
backup SIP server 1 39
backup SIP server 2 39
backup SIP servers, SIP server
backups 39
baud rate
verifying 15
boost (volume) 28
C
call button 18
LED 18
call button LED 18
call termination 30
changing
the web access password 27
Operations Guide
930939G
CyberData Corporation
Index 97
I
discovery utility program 23
DNS server 36
door sensor 47, 49, 52, 63
activate local relay 63
activate relay 49
dial out extension 49, 64
door open timeout 49, 63
door sensor normally closed 49
flash button LED 49, 63
play audio locally 49, 63
door strike intermediate relay 11, 12
download autoprovisioning template button 71
DTFM
play tone during DTMF activation 29
DTMF push to talk 30
DTMF tones 42, 44
DTMF tones (using rfc2833) 42
identifier names (PST, EDT, IST, MUT) 33
identifying your product 1
import settings 26
import/export settings 26
installation, typical intercom system 2
intercom configuration
default IP settings 19
intercom configuration page
configurable parameters 39
Internet Explorer (web browser) 3
intrusion sensor 47, 49
activate relay 49
dial out extension 49
flash button LED 49
play audio locally 49
IP address 19, 36
IP addressing
default
IP addressing setting 19
E
enable night ring events 57
ethernet I/F 5
event configuration
enable night ring events 57
expiration time for SIP server lease 40, 41
export settings 26
J
J3 terminal block, 16 AWG gauge wire 8
L
F
lease, SIP server expiration time 40, 41
LED
green link LED 15
yellow activity LED 15
lengthy pages 46
link LED 15
Linux, setting up a TFTP server on 93
local SIP port 40
log in address 23
factory default settings 17
how to set 17
Firefox (web browser) 3
firmware
where to get the latest firmware 81
flash button LED (door sensor) 49, 63
flash button LED (intrusion sensor) 49
G
M
get autoprovisioning template 71
GMT table 33
GMT time 33
ground cable installation 91
MGROUP
MGROUP Name 46
mounting 88
ground cable installation 91
network cable entry restrictions 91
overview of installation types 88
service loop cable routing 92
mounting components 88
Mozilla Firefox (web browser) 3
multicast configuration 51
H
home page 23
http POST command 84
http web-based configuration 4
Operations Guide
930939G
CyberData Corporation
Index 98
Multicast IP Address 46
supported protocols 4
supported SIP servers 4
typical system installation 2
product specifications 5
protocol 5
protocols supported 4
push to talk, DTMF 30
N
navigation (web page) 20
navigation table 20
network cable entry restrictions 91
network configuration of intercom 35, 66
Network Setup 35, 66
nightring tones 46
Nightringer 8, 80
nightringer settings 40
NTP server 29
R
reboot 82, 83
regulatory compliance 5
remote SIP port 40
reset test function management button 16
resetting the IP address to the default 88, 94
restoring factory default settings 17, 96
restoring the factory default settings 17
ringtones 46
lengthy pages 46
RJ-45 14
RMA returned materials authorization 95
RMA status 95
rport discovery setting, disabling 40
RTFM button 16
RTFM jumper 16, 17
RTP/AVP 4
O
on-board relay 5, 9
operating temperature 5
P
packet time 4
pages (lengthy) 46
part number 5
password
for SIP server login 39
login 23
restoring the default 19
payload types 5
pcb dimensions and intrusion sensor range 90
play audio locally (door sensor) 49, 63
play audio locally (intrusion sensor) 49
play tone during DTMF activation 29
point-to-point configuration 43
port
local SIP 40
remote SIP 40
posix timezone string
timezone string 29
POST command 84
power input 5
alternative 5
priority
assigning 46
product
configuring 19
parts list 6
product features 3
product overview
product features 3
product specifications 5
Operations Guide
S
Safari (web browser) 3
sales 95
sensor setup page 48, 62
sensor setup parameters 47
sensors 49, 63
server address, SIP 39
service 95
service loop cable routing 92
set time with external NTP server on boot 29
setting up an intercom 8
settings, default 17
SIP
enable SIP operation 39
local SIP port 40
user ID 39
SIP (session initiation protocol) 4
SIP configuration 38
SIP Server 39
SIP configuration parameters
outbound proxy 40, 41
registration and expiration, SIP server lease 40, 41
unregister on reboot 40
user ID, SIP 39
930939G
CyberData Corporation
Index 99
W
SIP registration 39
SIP remote SIP port 40
SIP server 39
password for login 39
SIP servers supported 4
unregister from 40
user ID for login 39
SIP volume 28
speaker output 5
SRST 39
subnet mask 19, 36
supported protocols 4
warranty policy at CyberData 95
web access password 19
web access username 19
web configuration log in address 23
web page
navigation 20
web page navigation 20
web-based intercom configuration 19
weight 5
wget, free unix utility 84
Windows, setting up a TFTP server on 93
wiring the circuit 10
devices less than 1A at 30 VDC 10
T
tech support 95
technical support, contact information 95
terminal block, 16 AWG gauge wire 8
TFTP server 4, 93
time zone string examples 33
U
unit dimensions—front and side view 89
user ID
for SIP server login 39
username
changing for web configuration access 27
default for web configuration access 23
restoring the default 19
V
verifying
baud rate 15
network connectivity 15
VLAN ID 36
VLAN Priority 36
VLAN tagging support 36
VLAN tags 36
volume
microphone gain 28
multicast volume 28
ring volume 28
sensor volume 28
SIP volume 28
volume boost 28
Operations Guide
930939G
CyberData Corporation

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement