Panorama_MV Distribution networks
Discovering our offer at a glance
Products and equipment for
Medium Voltage distribution networks
2014
Products and equipment for Medium Voltage
distribution networks
Medium Voltage Circuit Breakers & Contactors
1
Indoor Circuit Breakers
1
Indoor Contactors
3
Outdoor Circuit Breakers
3
Medium Voltage Switchgear
4
Air-Insulated Switchgear (AIS) for Primary Distribution
4
Motor Control
5
Air-Insulated Switchgear (AIS) for Secondary Distribution
5
Gas-Insulated Switchgear (GIS) for Primary Distribution
6
Gas-Insulated Ring Main Units for Secondary Distribution
7
Shielded Solid Insulation System
8
Medium Voltage Fuses
8
Medium Voltage Instrument Transformers
9
Medium Voltage Disconnectors, Switches,
Switch-Disconnections, Reclosers
10
Indoor Switch-Disconnectors
10
Pole-Mounted Switchgears
10
Control & Monitoring
12
Medium Voltage components for switchgear control
12
Feeder Automation
12
Remote monitoring and control
13
Protection & control relays
14
Medium Voltage Transformers
16
Oil Immersed Distribution Transformers
16
Oil Immersed Medium Power Transformers
16
Dry type Transformers
16
Special Transformers
16
Power Factor Correction
17
Medium Voltage / Low Voltage
prefabricated Substations (PSS)
18
Standard Substations - Integrated
18
Standard Substations - Compact
18
Standard Substations - Walk-In
18
Customized substations
19
Electrical Distribution Services
20
Medium Voltage Circuit Breakers & Contactors
Indoor Circuit Breakers
PE58001
PE57994
PE56501
PE56502
PE90232
PE90230
PE57191
Indoor Circuit Breakers
LF
LFP
SF1
SF400
SF2
Evolis 17.5 kV
Evolis 24 kV
IEC
IEC
IEC
IEC
IEC
IEC
IEC
Rated voltage (kV)
40.5
36
17.5
12
17.5
12
17.5
36
40.5
36
24
24
17.5
12
12
Max. rated current
3150 A
5000 A
1250 A
2500 A
1250 A
3150 A
40 kA
31.5 kA 40 kA
2500 A
2500 A
1250 A
2500 A
25 kA
31.5 kA
Max. rated short circuit current
50 kA
40 kA
50 kA
31.5 kA 25 kA
31.5 kA 31.5 kA
SF6
SF6
SF6
SF6
SF6
Vacuum
Vacuum
Fixed
or withdrawable
Circuit Breaker
Fixed Circuit
Breaker
Fixed Circuit Breaker
Withdrawable
Circuit Breaker
Fixed Circuit
Breaker
Front mounted
Front mounted
Fixed or
withdrawable
Circuit Breaker
Fixed
Circuit
Breaker
High power
version
for power pant
Front or side mounting
Conventional spring
Integrated VIP trip unit
(without auxiliary power
supply) in SFset up to 24 kV
(for side mounted)
Suited for capacitor bank
application
Panorama for MV distribution networks
Side
mounted
Fixed or
withdrawable
Circuit
Breaker
Front
VIP
mounted
integrated
trip unit
1
Indoor Circuit Breakers
PE90241
PE90339
PE90238
PE90239
PM102699
PE90236
PE90234
DE90217
Cradle/Cassette
HVX
HVX embedded pole
VR
VAH
VXC
ISF2
PMX cradle
IEC/ANSI/GB (Chinese)/
GOST standards
GB (Chinese)
standards
ANSI
IEC/ANSI/IEEE
IEC
IEC
EC
GB (Chinese)
GOST standards
Rated voltage (kV)
40.5
36
24
17.5
36
27
24
38
36
24
17.5
15
12
12
Max. rated current
2500 A
2500 A* 3150 A
2500 A
2500 A
3000 A
2750 A
8000 A
2500 A
4000 A
3150 A
3150 A
31.5 kA
31.5 kA
63 kA
40 kA
63 kA*
31.5 kA
40 kA
40 kA
40 kA
Vacuum
Vacuum
Vacuum
SF6
Vacuum
Withdrawable
Fixed or
withdrawable
Circuit Breaker.
Fixed or
withdrawable
Circuit Breaker.
For generator
applications
up to 130 MVA.
The arc furnace
Circuit Breaker
with high switching
numbers,
maintenance
free up to
25,000/75,000
cycles.
Fixed Circuit
Breaker for
electrical arc
furnace
Craddle
based on
PIX
switchgear
Max. rated short circuit current
50 kA
31,5 kA
50 kA
31.5 kA
Vacuum
Vacuum
Fixed or withdrawable
Circuit Breaker
Fixed or withdrawable Circuit Breaker
* 3150A performance is
possible. Please contact us
Vacuum
Embedded pole for better dielectric
and environmental pollution withstand
* ANSI / IEEE
C37.013
Generator
Switching
63 kA, 4000 &
5000 A
2
Panorama for MV distribution networks
www.schneider-electric.com
Medium Voltage Circuit Breakers & Contactors
Indoor Circuit Breakers
Indoor Contactors
Outdoor Circuit Breakers
Indoor Contactors
Outdoor Circuit Breakers
PE90250
PE90250
PM103787
PM103789
PM103784
PE60247
PE90284
DSCF2305
Railway
NEX cradle
VXA-VXB
Rollarc
CBX
CLX
CPX
FVR
VOX
IEC/GB
IEC/ANSI
IEC
IEC
IEC
IEC
ANSI
IEC / ANSI /
EATS / GOST
Rated voltage (kV)
38
17.5
24
38
27
25
15
12
7.2
12
7.2
7.2
3.6
Max. rated current
400 A (AC4)
400 A
(AC4)
315 A
(AC4)
400 A (AC4)
400 A (AC4)
2000 A
40 kA
10 kA
6 kA*
4 kA*
6 kA
4 kA
12.5 40 kA
Vacuum
Vacuum
SF6
Vacuum
Vacuum
Vacuum
Vacuum
Vacuum / SF6
Craddle based on
NEX
switchgear
1 or 2-pole
circuitbreaker
for railway
application or as
star point breaker
for grounding
application
Fixed or
withdrawable
contactor with
magnetic
holding or
mechanical
Fixed vacuum
contactor
In version
withdrawable
fused
vacuum
contactor:
CVX
Fixed vacuum
contactor
with magnetic
holding or
mechanical
Fixed
vacuum
contactor
with
magnetic
holding or
mechanical
Station breaker: fixed
outdoor Dead Tank
Circuit Breaker
Fixed outdoor
Dead Tank Circuit
Breaker
2500 A
2000 A
2500 A
2000 A
Max. rated short circuit current
31.5 kA
25 kA
Fix installation or
floor running truck
- 16 2/3 Hz
- 25 Hz
- 50Hz
- 60 Hz
8 kA
12.5 25 kA
12.5 31.5 kA
40 kA
*(50kA in
conjunction
with fuses)
1 or 3 poles
With magnetic
holding
or mechanical
Indoor
Panorama for MV distribution networks
3
AIS for Primary Distribution
MCset
PIX
PIX
Double Busbar
PIX High
NEX
IEC
IEC/
GOST
IEC
IEC/GOST
IEC/GB
IEC
IEC
PE90271
PE90272
PE90208
PM102825
PM103010
PM103575
PE57466
DM102184
Air Insulated Switchgear up to 24 kV
GenieEvo
DNF7
F400
IEC
IEC/GB/GOST
IEC / GOST
Rated voltage (kV)
40.5
40.5
36
24
17.5
24
17.5
17.5
17.5
12
LSC 2B PM
24
17.5
13.8
12
LSC 2B PM
LSC 2B PM
LSC 2B PM
LSC 2B PM
4000 A
3150 A
5000 A
2500 A
LSC 2A-PI
LSC2B-PM
2000 A
2000 A (SF CB)
2500 A
2500 A (Vacuum
CB). For 3150 A,
please consult us.
Max. rated current
4000 A
2500 A
2500 A
2500 A
2000 A
1250 A
LSC2B-PM
Max. rated short circuit current
50 kA
31.5 kA
40 kA
31.5 kA
31.5 kA
50 kA
31.5 kA
31.5 kA
25 kA
25 kA
31.5 kA
40 kA
31.5 kA
Vacuum* SF6
SF6
Vacuum*
Vacuum
Vacuum
Vacuum
Vacuum
Vacuum / SF6
SF6
Single busbar
system,
Withdrawable
Circuit
Breaker
Single busbar
system,
Withdrawable
Circuit Breaker
Double busbar
system,
Withdrawable
Circuit Breaker
Single busbar
system
Withdrawable
Circuit Breaker
Single busbar system
Withdrawable Vaccum
Circuit Breaker
Single busbar
system
Fixed type
Rear cable
access
Single busbar
system
Single busbar
system
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
IAC
IAC
IAC
IAC
IAC
IAC
IAC
IAC
IAC
* SF6 technology,
* Limited 31.5 kA please refer to
/ 2000A. Above,
MCset
please consult us.
4
Panorama for MV distribution networks
* up to
48 kV/20 kA
www.schneider-electric.com
Medium Voltage Switchgears
Air-Insulated Switchgear (AIS) for Primary Distribution
Motor Control
Air-Insulated Switchgear (AIS) for Secondary Distribution
Motor Control
AIS for Secondary Distribution
PE90698
PE90699
PE90700
PE90701
PM103007
PE90266
PE90291
PE90276
Railway
Masterclad
PIX DC
Motorpact
PIX MCC
SM6-24
SM6-36
HVL
HVL/cc
ANSI/UL
IEC/EN
IEC/NEMA
IEC
IEC
IEC
ANSI
ANSI
Rated voltage (kV)
38
36
27
38
24
15
12
7.2
0.75
7.2
1.5
LSC2A-PI
LSC 2B-PM
3150 A
5000 A (busbars)
Max. rated current
4000 A
2750 A
4000 A
630 A & 1250A
630 A
1250 A
1200 A
1200 A
25 kA
20 to 61 kA
32 kA
Open-air switch
SF6 switch
Fusible and nonfusible designs,
over toggle,
stored energy and
motor-operated
mechanisms
available
Fusible and nonfusible designs,
over toggle,
stored energy and
motor-operated
mechanisms
available
IAC
IAC
400 A contactor
Max. rated short circuit current
63 kA
40 kA
50 kA
50 kA
25 kA
20 kA
SF6 CB
Vacuum
Air
Vacuum
Vacuum
SF6
Vacuum CB
Single busbar
system
For light railway
segment
(tram/metro)
Withdrawable
double busbar
for S3
DOL
RVSS
RVAT
Reversing
2-speed
Withdrawable
Direct line-up
with PIX
Front access
cabling
(rear option)
DOL and feeder
applications
Complete system of modular Complete system
cubicles
of modular
cubicles
Indoor & Outdoor
Indoor & Outdoor
NEMA
Indoor
Indoor
Indoor
IAC
IAC
IAC
IAC
IAC
Width 650 mm
Panorama for MV distribution networks
40 kA
5
Gas-Insulated Switchgear (GIS) for Primary Distribution
PM102706
PE90705
PM102834
PM102833
PM103008
PM102831
PE90697
PM103068
Railway
GMA
CBGS-0
WS
GHA
CBGS 2
WI
GHA Rail
WI Rail
IEC / GOST /
CNS
IEC/ANSI (UL)
IEC / GOST /
CNS
IEC / GOST /
CNS
IEC
IEC / GOST /
CNS
IEC/GB (China)
IEC/EN
Rated voltage (kV)
52
40.5
38
36
52
36
1x
27.5
24
2x
27.5
1x
27.5
2x
27.5
Max. rated current
2500 A
2000 A
2000 A
2500 A
2500 A
2000 A
2500 A
2000 A
2000 A
Max. rated short circuit current
31.5 kA
31.5 kA
31.5 kA
40 kA
25 kA
40 kA
25 kA
31.5 kA
Vacuum
SF6
Vacuum
Vacuum
SF6
Vacuum
Vacuum
Vacuum
Single busbar
system
Fixed type
Mainly with C.B.
but also switchdisconnector
functions
Less Space-More
Power very
compact design
Flexible busbar
system
Outer cone cable
connection
No gas handling
Single busbar
system
Fixed type
Mainly with C.B.
but also switchdisconnector
functions
Single and double
busbar system
Fixed type
CB applications
Single and double
busbar system
Fixed type
CB applications
Single and double
busbar system
Fixed type
CB applications
Single and double
busbar system
Fixed type
CB applications
Single busbar
system
Fixed type
For traction
application,
1 or 2 pole
solution
Compact design
at 36kV
Flexible busbar
system
Outer cone cable
connection
No gas handling
Separated gasSeparated gasSeparated gasSeparated gascompartments
compartments
compartments
compartments
for CB and busbar for CB and busbar for CB and busbar for CB and
busbar.
Same small
Compact design, Spacious cable
footprint for
flexible cable
connection inner
Same small footSBB and DBB,
connection for
cone
print for SBB and
spacious cable
outer cone and
DBB, spacious
connection inner
inner cone, no
cable connection
cone
gas handling
inner cone
Single busbar
system
Fixed type
For traction
application
1 or 2 pole
solution
BIL 200 kV,
suitable
for traction side
container
Substation
No gas handling
BIL 250 kV,
suiteable for
traction side
container
Substation
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
IAC
IAC
IAC
IAC
IAC
IAC
IAC
IAC
6
Panorama for MV distribution networks
www.schneider-electric.com
Medium Voltage Switchgears
Gas-Insulated Switchgear (GIS) for Primary Distribution
Gas-Insulated Ring Main Units for Secondary Distribution
DM102666
PE90704
PE57770
PE90703
PE90702
DE60488
PM102833
Gas-Insulated Ring Main Units for Secondary Distribution
CBGS-0
CBGS-2
Ringmaster
FBX
RM6
DVCAS
Flusarc
IEC
IEC
IEC
IEC
IEC
IEC/ANSI/UL
IEC
Rated voltage (kV)
1x
27.5
1x
27.5
36
2x
27.5
24
13.8
40.5
38
36
24
12
12
Max. rated current
1250 A
2000 A
630 A
630 A
630 A
630 A
630 A
630 A
option busbar
1250A
Max. rated short circuit current
25 kA
25 kA
21 kA
25 kA
20 kA
25 kA
SF6
SF6
SF6 CB
SF6 LBS
Vacuum CB
SF6 LBS
SF6 CB
SF6 LBS
Vacuum CB
SF6 LBS
Vacuum CB
SF6 LBS
For railway
application 1 pole
(170kV BIL)
For railway
application 1 or 2
poles (250kV BIL)
Single busbar
system
Fixed type
For traction
application, 1 or 2
pole solution
Compact
and modular
switchgear
combining
all MV
functional units
Compact
and modular
switchgear
combining
all MV
functional units
Compact
and modular
switchgear
combining all MV
functional units
Wind dedicated
modular
switchgear
combining
all MV functional
units used in wind
farms
Compact and
modular
switchgear
combining
all MV functional
units
21 kA
25 kA
20 kA
BIL 250 kV,
suiteable for
traction side
container
Substation
Indoor
Indoor
Indoor and
outdoor
Indoor
Indoor
Indoor
Indoor &
Outdoor
IAC
IAC
IAC
IAC
IAC
IAC
IAC
Panorama for MV distribution networks
Indoor
7
MV Fuses
PE90706
PM100599
2SIS
Premset
Fusarc CF
Solefuse
Tepefuse,
Fusarc CF
MGK
IEC
DIN/IEC
IEC/UTE
IEC/DIN/UTE
AFNOR
Rated voltage (kV)
36
36
36
15
12
7.2
Max. rated current
630 A
250 A
5000 A (busbars)
400 A contactor
Max. rated short circuit current
25 kA
63 kA
50 kA
63 kA
50 kA
Fuses for
distribution
transformer protection
from 3.6 kV
to 36 kV
Fuses for distribution
transformer protection
from 3.6 kV to 36 kV
Fuse for measurement
transformer protection
up to
24 kV (Tepefuse)
and up to
36 kV
(Fusarc CF)
Back-up technology
Motor
protection
fuse range
Vacuum CB
Compact modular
switchgear with
3-in-1 architecture for
breakingdisconnection and
earthing
Indoor & Outdoor
IAC
8
Panorama for MV distribution networks
www.schneider-electric.com
Medium Voltage Switchgears
Shielded Solid Insulation System (2SIS)
Medium Voltage Fuses
Medium Voltage Instrument Transformers
PM103005
PM103014
PE90529
PE90297
PM103013
PE90303
PE90302
PE90296
MV Instrument Transformers
Indoor
CT / VT
Sensor
Low Voltage
Ring Core
Outdoor
CT / VT
Indoor
CT / VT
Combined
Outdoor Unit
Outdoor
VT
IEC
IEC
IEC
IEC
IEC/IEEE
IEC/IEEE
IEC/IEEE
Rated voltage (kV)
72
40.5
40.5
36
36
24
0.72
Max. rated current
2500 A
2500 A
5000 A
2500 A
3000 A
600 A
1500 A
Max. rated short circuit current
50 kA
40 kA
40 kA
50 kA
50 kA
50 kA
40 kA
Dry
Dry
Dry
Dry
Dry
Dry
Dry
Medium Voltage
Current
Transformer,
Voltage
Transformer
Ring type and
Medium Voltage
Low Power Current
Transformer (LPCT)
Ring type
Low Voltage
Transformer
Outdoor Current
Transformer
and Voltage
Transformer
Ring or Bar type
Current Transformer
and
Voltage
Transformer
Outdoor
combined CTs
VTs measure
units for aerian
and underground
applications
Outdoor Current
Transformer
and Voltage
Transformer
Panorama for MV distribution networks
9
PE90712
PE90711
PE90710
PE90709
PE90708
Pole mounted switchgears
PE90707
Indoor Switch-Disconnectors
LBSkit
L-TRI 5
TRI
PM6
PM6 52
RL series
N series
IEC
IEC
IEC
IEC
IEC
IEC/ANSI
IEC/ANSI
Rated voltage (kV)
52
38
36
36
36
38
36
12
Max. rated current
630/1250 A
630/1600/2500 A
630 A
630 A
630 A
800 A
Max. rated short circuit current
25 kA
20 kA
20 kA
16 kA
12.5 kA / 3 s
16 kA
16 kA
SF6
AIR
AIR
SF6
SF6
Vacuum / SF6
Vacuum / SF6
Indoor load break
switch, disconnector
and accessories
Indoor load
break switch
disconnector
and
accessories
Indoor
disconnector
and
accessories
Load break switch
Load break switch
Recloser
Remote controlled with Easergy T200 P
control unit
Remote controlled
with ADVC controller
Remote controlled
with ADVC controller
Manual or automatic load break switch
Manual or
automatic
load break switch
Advanced protection,
control and
communication
Sectionaliser capabilities
Sectionaliser
capabilities
on voltage and
current
10
Panorama for MV distribution networks
www.schneider-electric.com
Medium Voltage Disconnectors, Switches, Switch-Disconnections, Reclosers
Indoor Switch-Disconnectors
Pole-Mounted Switchgears
PE90290
PE90289
PE90292
PM102689
PM102691
PE90715
PE90714
PE90713
Railway
U series
W series
SBC
SDR
CBR
22 CB
NE
TILF
IEC/ANSI
IEC/ANSI
IEC
IEC
IEC
IEC
IEC/SNCB
IEC/SNCB
Rated voltage (kV)
36
27
27.5
27.5
25
(1ph)
24
15
3.8
3.8
Max. rated current
630 A
400 A
630 A
2000 A
2000 A
1000 A
2000 A
3150 A
25 kA
16 kA
25 kA
25 kA
Single pole load
break switches
for DC railway
networks
Single pole load
break switches
for DC railway
networks
Max. rated short circuit current
12.5 kA
6 kA
20 kA
25 kA/
40 kA
Vacuum / Epoxy
Vacuum / Epoxy
Air
Vacuum
Vacuum
Vacuum
Fixed load break
switch for AC
railway
application
Fixed Circuit
Breaker for
AC railway
application
For locomotives
and Electric
Multiple Units
(EMU)
Recloser
Single Wire Earth Air break switch
Return (SWER)
and disconnector
Remote controlled recloser
with ADVC
Manualy operated
controller
Remote controlled
with ADVC
Advanced
controller
protection,
control and
Advanced
communication
protection,
control and
communication
8 kA/
25 kA
Outdoor on
locomotive top
Outdoor
Outdoor
On board
Panorama for MV distribution networks
11
MV components for switchgear control
Feeder Automation
Remote
MV/LV
Monitoring for MV Substation
Substations
Remote Control for MV Substations
PM102301
PE90718
DM103098
DM103099
PE90717
PE90716
PE90343 V3
PM102822
PE90295
PM102820
power supply
GemStart 5.4
GemStart 5
GemView
GemControl
Easergy L500
Easergy
T200I - T200E
Easergy
R200-ATS100
Easergy
Flair 200C
Easergy PS100
Ideal for IEC
MV & LV motor
starters with
ratings from 0.5
kW to
2 MW. Partnered
with PIX MCC
and also suitable
for Motorpact
/ OKKEN
Hand Held
Programmer
Exclusive to
GemStart5
Highest
possible security.
Avoids the use of
laptop
Requires a Key
for
protection
modification
PLC and PC
based solution for
MV & LV Process
control systems.
Partnered
with GemStart 5,
PIX MCC and LV
Switchgear
Smart Switchgear
Management
Digital control &
monitoring
solution for airinsulated and
gas-insulated
switchgear from
simple to
complex
applications,
due to its very
scalable design
Remote control
system
Switch
monitoring and
control unit
Switch
monitoring and
control unit
Detection
Phase and earth
fault
Fault indicator:
phase and earth
fault
Installation
Wall-mounted
Data
configuration
Professional
communications
and database
editor
Data creation via
dialogue
boxes
Battery
autonomy 16 h
Control and
monitoring
through
embedded
devices in MV
switchgear
Premset, SM6
(end 2014)
Power supply
and battery
charger for MV/
LV substation.
Digital
Scada
Digital
Digital
Digital
Digital
Associated with
all types of MV
switchgear
Ensure remote
control and
automated
management.
Embedded web
server.
Local and remote
configuration
MV substation
remote
monitoring unit
7 to 40 Ah lead
long life battery
Input voltage:
- 110 to 240 VAC
- 110 VDC
Applications:
Intelligent Motor
Applications:
Control and
Integrated Motor
Monitoring
Control and
Applications:
System
Protection. Multi Ensures full
(IMCS) to
line LCD front
compliance with Chevron, Shell,
panel, multi
best practice and BP, Exxon
voltage input
permit to work
Mobil, Conoco
solution requiring principles in
Philips and most
no interposing
Oil & Gas
other Oil & Gas
relays.
applications.
standards
Exclusive
Work at
Predictive
Memory
a convenient
maintenance,
Module (PAMM), height with user
trending, alarms,
Self Tuning
friendly control
plant visualisation
protection.
and reset
in a semi
Industry
buttons.
standard
leader and
Only authorised
/ custom
standard in many operators may
package.
Oil & Gas
confi gure or
Completes
applications
reset trips
the Oil & Gas
world-wide
solution offer.
Protocols:
Modbus RTU,
Profi bus DP V1
using Generic
Motor
Management
profile
for plug and play
solutions
Digital
Digital
Capacity
500 Easergy type
devices
Network and
substation views
Alarm logs,
archives
Capacity
1-16 switches
Autonomy up
Measurement
to 48h
Applications:
Motorisation
U,I, P, Q, S, cosϕ
Switchgear
24 - 48 VDC
6 D.I., 3 D.O.
90W for 24/48V
central control
Control unit:
permanent load
unit, central
Protocols
SC110
Protocols
300W 1mn for
monitoring
Modbus/IP,
Modbus/IP,
motor supply
and central
IEC 870-5Backup power
IEC 870-510kV insulation
information
101/104,
supply: PS100
101/104,
source,
Protocols
DNP3, DNP3/IP
DNP3, DNP3/IP Monitoring
separated from
Modbus, Modbus
Protocols
of battery to
protection
IP, IEC 101/104
Communication Modbus/IP,
Communication detect end of life
function.
Radio, PSTN,
IEC 870-51 communication through Modbus
Advanced front
Communication GSM, GPRS, 3G 101/104,
port
communication
panel for safe
Permanent and
DNP3, DNP3/IP Transmission
and intuitive
non permanent: Programmation
interfaces:
guided operation. telephone/
IEC 61131-3
Communication PSTN, radio,
Base Unit with
GSM, radio,
Radio, PSTN,
GSM, GPRS,
open SCADAdirect public and Modbus IEDs
GSM, GPRS, 3G Ethernet, RS232,
Communication
dedicated
concentrator
RS485...
for standard IEC- private line
Modbus IEDs
Protocols:
protocols and
Periodic call
concentrator
Modbus IEDs
Modbus RTU,
industry
management
concentrator
Profi bus DP V1, protocols.
Ethernet TCP I/P Sofware based
Option
A library of other on robust
Webview,
protocols is
standard PLC
Multistation and
available
software.
Horn/Lamp
to integrate other Direct process
indication options
devices and
control possible
protection relays
Protocols:
IEC 60870-5-101
Modbus-RTU
Profibus-DP
IEC 60870-5-103
IEC 60870-5-104
IEC 61850,
Modbus TCP
PLC / PC /
Software
T200E
associated with
Ringmaster only;
limited to
4 switches.
Ensure remote
control and
automated
management.
Embedded web
server.
Local and remote
configuration
12
Earthing
system: direct,
impedent,
compensated,
isolated
24V or 48V for
motor and IEDs
supply
12V for
communication
device supply
Panorama for MV distribution networks
Fault indicator:
Flair 23DM
Battery
220 VAC backedup supply
Embedded web
ATS100:
server.
automatic source Local and remote
transfer with
configuration
dedicated front
panel.
Lines, generator,
bus tie
www.schneider-electric.com
Control & Monitoring
Remote
monitoring
and control
Easergy Flair 219,
279
Easergy Flair 510,
570, 590
Easergy
Flair 21D, 22D,
23D, 23DM
Easergy T200P
ADVC
Easergy Flite 116SA/G200
Easergy Flite
Detection
phase and earth
fault
Detection
phase and earth
fault
Detection
phase and earth
fault
Switch or
sectionaliser
monitoring and
control unit
Control
Controls recloser
Detection
Phase-to-phase
and phase-to-earth
fault
Detection
phase and earth
fault
Setting
Setting
on site by dip switch on site by HMI
through
Installation
push buttons
wall mounted
3 phases or / and
Installation
earth CT
wall mounted
3 phases or / and
Earthing system
earth CT
direct, impedant
Earthing system
direct, impedant,
compensated,
isolated
Setting
on site by dip switch Fault indicator:
or with keyboard
phase and earth
fault
Installation
DIN format
Measurement
integrated into
Current, voltage,
switchgear
real power,
reactive power,
Earthing system
power factor,
direct impedant,
demand, cosϕ
compensated,
isolated
Capacity
2 switches
Measurement
ammeter,
Battery autonomy
maximeter
16h
Motorisation
voltage
24-48 VDC
Protocols
Modbus, Modbus/
IP, IEC 870-5101/104, DNP3,
DNP3/IP
PE90726
PE90725
Fault Passage
Indicators for
Overhead Networks
PE90724
Remote Monitoring
for Overhead
Networks
PE90723
PE90722
Telecontrol interface for
pole-mounted load-break switch
PE90721
PE90720
PE90719
Fault Passage Indicators for Underground Networks
ILIS
ILIS (Intelligent
Light
Information System)
Protection
Monitors light levels
Phase and earth
Setting
within Switchgear
current,
Installation
on site by dip switch compartments
directional, voltage, clip on or G200 pole
Applications:
frequency,
mounted
Installation
Detects and
harmonics
clip on or pole
disconnects ARC
Protocols
mounted
faults to limit
Detection
IEC 870-5-101,
damage
Phase and earth
Serial
Earthing system
to equipment.
faults, directional
DNP3 and TCP/IP, direct, impedant,
Diffuse
Modbus
compensated,
light collection from
Measurement
isolated
all directions, rapid
Current, voltage,
Communication
timed disconnect
real power,
915 MHz short
between 5 and
power factor,
range radio
250mS.
demand,
communication
Monitors up to 4
harmonics, supply
1 SCADA
compartments per
outages,
communication
column and up to 5
waveform capture
port
columns on 4
Transmission
independant loops
Setting
interface:
By laptop, operator radio, GSM, GPRS
control panel,
Scada
Installation
Mounted on the
pole or substation
frame
Communication
Radio, PSTN, GSM, Protocols
GPRS 3G
DNP3, IEC 870-5101/104
Modbus IEDs
Modbus/IP and
concentrator
DNP3/IP
Communication
Radio, modem,
GSM, V23,
RS232, RS485,
10BaseT Ethernet
Digital
Digital
Digital
Digital
Digital
Digital
Phase and earth
fault indicator for
underground
network
Phase and earth
fault indicator for
underground
network
Associated with
a pole mounted
switch
Power supply:
- Flair 219: lithium
battery
- Flair 279: 220 VAC
with backup lithium
battery
Power supply :
- Flair 510: Lithium
battery
- Flair 570: 110-220
VAC with backup Li
battery
- Flair 590: 110-220
VAC with backup
super capacitor
Phase and earth
fault indicator for
underground
network. Self
powered by CTs
Advanced controller
associated with N, U
and W Series
reclosers, and RL
Series sectionaliser
Earth and
phase-to-phase
fault indicators
for overhead
distribution lines
Lithium
battery power
1 output contact
2 output contacts
2 input contacts
Power supply :
- Flair 510: Lithium
battery
- Flair 570: 110-220
VAC with backup Li
battery
- Flair 590: 110-220
VAC with backup
super capacitor
2 output contacts
2 input contacts
Ensures remote
control
and automated
management
Embedded web
server.
Local and remote
configuration
Communicating
fault current
detector for
overhead
lines
Single-phase
Remote setting with ammetric detector
WSOS monitoring
and control
software
Electronics sealed
to IP65, 316 grade
stainless steel
enclosure
Control recloser
Load Break Switch/
Sectionnaliser
type RL series
Panorama for MV distribution networks
13
Sepam
series 10
Sepam
series 20
Sepam
series 40
Sepam
series 60
Sepam
series 80
MiCOM
series 10
Protection
relay for basic
applications
Protection relay
for standard
applications
Multi-function
protection relay
for demanding
applications
Multi-function
protection relay for
high-performance
applications
Multi-function
protection unit for
critical and
customised
applications
Protection relays Protection relays
for basic electrical for standard
schemes
electrical
schemes
Multi-function
protection relays
for
complex electrical
schemes
Secondary Power
Distribution
Networks
Utility MV and
Industrial
Distribution
Networks
Utility MV and
Industrial
Distribution
Networks
Utility MV and
Industrial
Distribution
Networks
Utility MV,
Generation
and Industrial
Distribution
Networks
MV Industrial and
Building Networks,
Secondary and
Primary
Distribution
Networks
Primary
Distribution,
MV Substations
and Industrial
Networks
Industrial
Networks,
Railways and
Utility MV, HV
Substations
Feeder
Transformer
Feeder
Busbar
Transformer
Motor
Feeder
Generator
Transformer
Motor
Feeder
Generator
Transformer
Motor
Capacitor
Feeder
Busbar
Transformer
Motor
Generator
Capacitor
Feeder
Motor
Feeder
Motor
Busbar
Line Differential
Feeder
Motor
Transformer
Line Differential
Distance
Rail
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Modbus RTU
DNP3
IEC 60870-5-103
Modbus TCP/IP
Modbus RTU
Modbus TCP/IP
DNP3
IEC 60870-5-103
IEC 61850
Modbus RTU
Modbus TCP/IP
DNP3
IEC 60870-5-103
IEC 61850
Modbus RTU
Modbus TCP/IP
DNP3
IEC 60870-5-103
IEC 61850
Modbus RTU,
IEC 60870-5-103
Modbus RTU
DNP3
IEC 60870-5-103
Courier
Modbus RTU
DNP3
IEC 60870-5-101
IEC 60870-5-103
Courier
IEC 61850
Panel
Panel
Panel
Panel
Wall/Surface,
Panel or DIN Rail
Panel or Rack
(with adaptor)
Panel, Wall/
Surface or Rack
Panel
14
Panorama for MV distribution networks
MiCOM
series 20
PM100527
PM100522
PM100502
PE88024
PE88023
PE88022
PE88030
PM102703
Protection
MiCOM
series 30
www.schneider-electric.com
Control & Monitoring
PM103532
PM100526
Protection & control relays
MiCOM
series 40
VAMP
Multi-function
protection relays
for complex
electrical
schemes
Dedicated Arc
Protection
Schemes
Industrial
Networks,
Generation
and Utility
MV, HV
Substations
Feeder
Motor
Transformer
Line Differential
Distance
Busbar
Generation
Arc Protection
Communication
Protocol
Digital
Digital
Modbus RTU
DNP3
IEC 60870-5-103
Courier
IEC 61850
Modbus RTU
Modbus TCP
IEC 61850
DNP3 TCP
Profibus
IEC 60870-5-101
IEC 60870-5-103
Panel or Rack
Panel or DIN Rail
Panorama for MV distribution networks
15
Medium Voltage Transformers
Oil Immersed Distribution Transformers
Medium Power Transformers
Dry type Transformers
Special transformers
MINERA ODT
Pole and ground mounted
MINERA MP
TRIHAL
SPT
Oil immersed type
Rated voltage (kV)
PE90749
Special Transformers
PE90750
PE90735
Dry type Transformers
PE90734
Oil Immersed Medium
Power Transformers
PE90732
PE90733
Oil Immersed Distribution
Transformers
170
Dry type
170
36
52
36
Power ratings
From 25 kVA up to 3.15 MVA
> 3.15 up to 80 MVA
From 100 kVA up to 15 MVA
Up to 80 MVA
Up to 30 MVA
50 Hz - 60 Hz
50 Hz - 60 Hz
50 Hz - 60 Hz
50 Hz - 60 Hz
Mineral Oil – IEC60296
L Class
Fire resistant oil (Vegeta)
K Class (K2 - K3)
Cast Resin encapsulated
Certified C3* E3 F1
Standard losses
High Efficiency
(Minera HE & HE+)
Standard losses
High Efficiency (Trihal HE)
Custom solutions. Special applications
- Compact Minera Siltrim
- Minera EX (Zone 1 and 2)
- Photovoltaic Minera PV
- Compact Minera PAD
- Full cast Tricast
- Furnace transformer
- Rectifier transformer
- Generator transformers
- Motor starting reactors
- Others upon request
- IP54, IP55 Dry Type Outdoor Transformers
- Auto transformers
- Single Phase Transformers
- Self Protected Transformer
- Dry Type Transformer with OLTC
Frequency
50 Hz - 60 Hz
Dielectric
Mineral Oil – IEC60296
L Class
Fire resistant oil (Vegeta)
K Class (K2 - K3)
Optimized efficiency
Standard losses
High Efficiency
(Minera HE & HE+)
Cooling system
ONAN – Natural air
ONAF – Air forced
(up to 40%)
ONAN, ONAF, ODAF, ODWF AN - Natural air
or OFAF
ANAF / AF – Air forced (up to
+40%)
Tank / Enclosure types
Hermetically sealed
Breathing type
16
Hermetically sealed, gas
cushion transformers
Free-breathing with expansion
tank
Common Design – Indoor use
IP21, IP31, IP23
Custom Enclosure – Outdoor
use
IP35, IP44
Panorama for MV distribution networks
www.schneider-electric.com
Power Factor Correction
PE90727
PB108151
Power Factor Correction
Propivar NG
CP 200 series
IEC
IEC
Rated voltage (kV)
36
36
Max. rated current
900 kVAR
14400 kVAR
Max. rated short circuit current
31.5 kA
"All film"
with or without
internal fuses
Vacuum / SF6
Power factor
correction on
MV networks
or devices
Power factor
correction and
harmonic filtering
on MV networks
Fixed or automatic
capacitor banks for motor,
substation,
or global
distribution
Indoor or outdoor
installation
Panorama for MV distribution networks
17
Medium Voltage / Low Voltage Prefabricated Substations (PSS)
IEC
BS
PM102382
PE90741
PE90738
Standard Substations - Walk-in
PE90737
PE90740
Standard Substations - Compact
PE90739
Standard Substations - Integrated
MV Switching kiosk
MV/LV external operations
MV/LV internal operations
MV/LV Underground
IEC / AS / HN
IEC / AS / HN
IEC / HN
IEC
Rated voltage (kV)
36
36
36
36
36
17.5
Transformer maximum power (kVA)
Non applicable /
without transformer
2000
2000
1250
1x
1000
630
2x
630
Enclosure material
Without (frame mounted)
■ ■
■■■
■■■
■
Outdoor
Outdoor
Indoor
Indoor
Mode of operation
Indoor
Indoor / Outdoor
Description
The MV and LV equipment are delivered directly
mounted ensuring a safety, and fast solution.
They can be installed in existing building,
in a substation or outdoor*
Outdoor operations type of substation allows reduce
footprint and speed of installation.
Internal equipment arrangement can be fitted to
any type of access
Indoor operation provides to operator protection against
bad weather and better working conditions. It offers fast
delivery, safety and quick erection versus traditional
construction. MV/LV Underground substations are invisible
and fully integrated into the environment, allowing space
saving whilst maintaining a high level of safety
Distribution, buildings
Distribution, industry,
wind, buildings
Distribution, industry,
wind, buildings
Protection and
reconfiguration of the MV
undergrounded network.
Equipped with MV Ring
Main Units switchgears.
Managing functions
remotely with Easergy
Flair 200C, Easergy
T200 and Easergy W200
Reconfiguring the MV
network and protecting
the MV/LV transformer with
our MV switchgear ranges.
Supplying LV energy with
oil transformer (Minera
ranges or equivalent)
and with cast resin dry
type transformer (Trihal
ranges or equivalent).
Distributing and protecting
the LV network with Opus
and Prisma Plus ranges.
Managing functions
remotely with Easergy Flair
200C, Easergy T200 and
Easergy W200
Reconfiguring the MV network and protecting
the MV/LV transformer with our MV switchgear
ranges. Supplying LV energy with oil transformer
(Minera ranges or equivalent) and with cast resin
dry type transformer (Trihal ranges or equivalent)*.
Distributing and protecting the LV network with Opus
and Prisma Plus ranges.
Managing functions remotely with Easergy Flair
200C, Easergy T200 and Easergy W200
*BS version
Application
Distribution
Buidings
Distribution, industry,
buidings
Reconfiguring the MV network and protecting
the MV/LV transformer with our MV switchgear
ranges. Supplying LV energy with oil transformer
(Minera ranges or equivalent). Distributing and
protecting the LV network with Opus and Prisma
Plus ranges.
Managing functions remotely with Easergy Flair
200C, Easergy T200 and Easergy W200
Distribution, buildings
*Non applicable to underground substations
■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete
18
Panorama for MV distribution networks
www.schneider-electric.com
Specific substations (PSS)
Prefabricated Substations
Electrical House (E-House)
Mobile substations
All voltage levels
MV
All voltage levels
All voltage levels
IEC, AS, BS, ANSI/NEMA...
IEC, AS, BS, ANSI/NEMA...
Building codes: Eurocodes,
IBC, BCA
Building codes: Eurocodes,
IBC, BCA
IEC, HN
Building codes: Eurocodes
(according to specific type of
substations)
PE90325
PE90317
PE90313
PE90736
PM102835
Customized substations
Trackside substations
Rated voltage (kV)
up to
72
40.5
up to
72
36
27.5
2x
27.5
15
Transformer maximum power (kVA)
3150
MV switchgear
Automation
RTU
UPS
MV switchgear
MV MCC
LV switchgear
LV MCC, VSD,...
Automation
UPS
RTU,...
10MVA transformer
HV/MV switchgear
on & off-load tap
changers blackstart genset,
UPS
RTU & Sat Com
Cable reel
MV switchgear
Automation
UPS
RTU
■
■
Truck mounted
■
These substations offer
modularity of their dimensions
to respond to all equipment
requirements
These substations offer
modularity of their dimensions
to respond to all equipment
requirements
Complete stand-alone substation
permanently mounted on a standard
semi trailer to offer full mobility at
highway speed without escort
These substations offer
modularity of their dimensions
to respond to all equipment
requirements
Pre-fabricated primary
substation complete with
its ancillary equipment ready
to be shipped,
allowing minimal site work
Pre-fabricated substation
comprising primary supply and
processcontrol switchgear,
complete with ancillary
equipment ready to be shipped,
allowing minimal site work
Emergency power supply to
back-up any HV/MV
transformer within a Utility
network in less than 4 hours
Electrical supply of
catenaries for main lines,
high speed lines or freight
lines
Primary distribution,
Large industries
Oil & Gas
Mining & Metals
Solar & Wind
Oil & Gas - Upstream,
midstream, downstream
Utilities - HV/MV substations
Mining & Metals
Energy - Intensive industries
Utilities - Primary or reflection
substations
Railways - Trackside
substations
Primary distribution
Railways
Mining & Metals
Enclosure material
■■
Mode of operation
Indoor
Description
These tailor made substations
offer modularity of
their dimensions to respond
to all equipment requirements
Application
Primary and Secondary
distributions, Large industries,
Oil & Gas, Mine & Metal, Solar
& Wind
■ Metal ■ GRC (Glass ReinforcedCement) ■ Concrete
Panorama for MV distribution networks
19
Electrical Distribution Services
Comprehensive Electrical
Installation Services from
Schneider Electric
20
Your Electrical
Distribution Equipment
Panorama for MV distribution networks
Greater Productivity,
Reliability, and
Safety
www.schneider-electric.com
Electrical Distribution Services
Comprehensive Installed Base Services
Renew
- ECOFIT™
- Modernization solutions
- Infrastructure enhancement
Plan
- Technical Feasability studies
- Architecture & Design studies
- Facility assessment
ew
Ren
What are
my options?
How do I
install and
commission?
How do I
operate and
maintain?
Op
e ra
a ll
How do I
optimize?
st
Asset
Management
Life Cycle
In
How do I
renew my
solution?
Optimize
-R
emote Monitoring
Services
- Maintenance consulting
-O
n-Site energy,
reliability
- Safety assessment
an
Pl
Optimize
te
Install
Operate
- Warranty Extensions/ Service Plans
- Expert Technical support
- Preventive / Predictive Maintenance
- Spare Parts management
- Technical Training
- Project management
- Site coordination
- Assembly &
Start-up commissioning
Peace of mind for every stage
of the lifecycle
Panorama for MV distribution networks
21
www.MyEnergyUniversity.co.kr 사이트에 키코드 43633y를 등록하시면 에너지 효율
Schneider Electric Korea Ltd.
슈나이더 일렉트릭 코리아(주)
모바일웹
페이스북
고객센터 : 1588-2630
웹사이트 : www.schneider-electric.co.kr
카
페 : www.energyforum.co.kr
트 위 터 : twitter.com/SchneiderKorea
블 로 그 : www.sch-log.com
페이스북 : www.facebook.com/SchneiderElectric
NRJED111210EN ⓒ 2014 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its aliated companies.
향상 교육을 무료로 수강하실 수 있습니다. 지금 방문하시고 에너지 효율 챔피언이 되십시오!
서울 본사
부산 지사
대구 지사
대전 지사
천안지사
서울 마포구 성암로 189 중소기업 DMC타워
동훈빌딩 5층
Tel. 02 2630 9700
Fax 02 2630 9800~1
부산시 사상구 괘법동 559-13
크리스탈빌딩 401호
Tel. 051 319 7901
Fax 051 319 7900
대구 북구 산격2동 1666 전기조명관 오피스텔 A동 836호 Tel. 053 604 6028
Fax 053 604 6029
대전 유성구 관평동
1342 디티비안 C&J빌딩 903호
Tel. 042 822 3240
Fax 042 822 3241
충남 천안시 서북구
불당동 724
Tel. 041 552 0501
Fax 041 552 0599
This is only a summary of the product features and is for reference purpose only. The information herein is provided to you "AS IS" AND WITHOUT WARRANTY OF ANY KIND,
EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR
NON-INFRINGEMENT. While the information provided is believed to be accurate, it may include errors or inaccuracies; we assume no liability for errors or omissions in the content
of the information nor do we accept any liability as a result of reliance upon the information contained herein. In no event shall we be liable to any person for any special, indirect or
consequential damages relating to this material, unless caused by gross negligence or intentional misconduct.
03/2014
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement