Cross Technologies 2017-05A Up+Downconverter, 140 MHz 950-2150 MHz Owner's Manual
Cross Technologies 2017-05A
The Cross Technologies 2017-05A is an up/downconverter that can convert 140 MHz to 950-1525 MHz (Up) and 950-1525 MHz to 140 MHz (Down) in 1 MHz steps with low group delay and flat frequency response. It has a lower RF level out of the upconverter and a higher RF level into the downconverter than the 2017-05 and is typically used to interface an L-band modem to a 140 MHz IF upconverter and downconverter.
The 2017-05A has several features that make it a versatile and powerful tool for a variety of applications. These features include:
- Multi-function push buttons that select the RF frequency, gain, and other parameters.
PDF
Download
Document
Advertisement
Advertisement
Model 2017-05A Instruction Manual Up/Downconverter December 2008 Rev. A MODEL 2017 DOWNCONVERTER UPCONVERTER U F=1525 D F=1450 G=+10.0 G=+25.0 UP/DOWNCONVERTER MENU CROSS TECHNOLOGIES INC. EXECUTE ALARM REMOTE POWER MUTE ALARM Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] INSTRUCTION MANUAL Model 2017-05A Up/Downconverter TABLE OF CONTENTS Warranty 1.0 General 1.1 Equipment Description 1.2 Technical Characteristics 1.3 Monitor & Control Interface 1.4 Use Information 2.0 Installation 2.1 Mechanical 2.2 Rear I/O’s 2.3 Front Panel Controls, Indicators 2.4 Operation 2.5 Menu Settings PAGE 2 3 3 4 5 8 9 9 10 12 13 15 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] 2017-05A Manual, Rev B Page 2 12/03/08 Model 2017-05 Up/Downconverter 1.0 General 1.1 Equipment Description The 2017-05A L-band Up/Downconverter converts 140 MHz to 950-1525 MHz (Up) and 950-1525 MHz to 140 MHz (Down) in 1 MHz steps with low group delay and flat frequency response. The 2017-05A has lower RF level out of the upconverter and higher RF level into the downconverter than the 2017-05 and is typically used to interface an L-band modem to a 140 MHz IF upconverter and downconverter. Multi-function push button switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL alarm for up and downconverters (red), remote operation (yellow), and Upconverter mute (yellow). Gain can be manually adjusted over a -25 to +15 dB range for the upconverter and over a 0 to +50 dB range for the downconverter by the front panel multi-function push-button switches. Remote operation allows selection of frequency and gain. Parameter selection and frequency and gain settings appear on the LCD display. Connectors are BNC female for IF and the optional external reference input and output, and Type F female for RF. A high stability (±0.01ppm) option is also available. It is powered by a 100-240 ± 10% VAC power supply and housed in a 1.75” X 19“ X 16” 1RU chassis. MODEL 2017 DOWNCONVERTER U F=1525 D F=1450 UPCONVERTER UP/DOWNCONVERTER G=+10.0 G=+25.0 MENU CROSS TECHNOLOGIES INC. EXECUTE ALARM REMOTE POWER MUTE ALARM FRONT PANEL AC UPCONVERTER DOWNCONVERTER RF IN GND IF OUT LNB FUSE F1 10 MHZ REF OUTPUT MONITOR AND CONTROL 10 MHZ EXT REF INPUT IF IN J3 J4 SSPB FUSE F2 RF OUT 5 4 3 2 1 9 8 7 6 VDC on RF J2 J1 DS8 J18 VDC on RF J10 DS7 J5 REAR PANEL Figure 1.1 Model 2017-05A Front and Rear Panels 0.95 to 1525 GHz IN 10MHz* +24VDC* 0.95 to 1.525 GHz BP 2400 MHz BP var atten 2260 or 2540 MHz 3.3 to 4.5 GHz REF TO UP VCOS CONTROLLER *OPTIONAL 2540 MHz 140 MHz IN 120 MHz LP 3.3 REF to 4.5 GHz U F=1525 D F=1450 var atten 2400 MHz BP 0.95 -1.525 GHz EXT 10MHz* INT 10MHz G=+00.0 G=+25.0 10MHz* +24VDC* REF var atten 140 MHz OUT 0.95 to 1525 GHz OUT Figure 1.2 Model 2017-05A Up/Downconverter Block Diagrams 2017-05A Manual, Rev B Page 3 12/03/08 1.2 Technical Characteristics TABLE 1.0 2017-05A Up/Downconverter Specifications* DOWNCONVERTER UPCONVERTER Input Characteristics (RF) Impedance/Return Loss Frequency Noise Figure, max. Level 1dB compression Output Characteristics (IF) Impedance/Return Loss Frequency Level 1dB compression Channel Characteristics Gain range (adjustable) Image Rejection Frequency Sense Input Characteristics (IF) Impedance/Return Loss 75 /18 dB Frequency 140 ± 36 MHz Level -40 to -10 dBm Output Characteristics (RF) Impedance/Return Loss 75/12 dB Frequency 950 to 1525 MHz Level -35 to -15 dBm 1dB compression -10 dBm Channel Characteristics Gain range (adjustable) -25 to +15 dB, 1dB steps Frequency Sense Non-inverting UP & DOWNCONVERTER 75 /12 dB 950 to 1525 MHz 15 dB (max gain) -60 to -10 dBm -5 dBm 75/18 dB 140 ± 36 MHz -10 to 0 dBm +5 dBm 0 to +50 dB, 1dB steps > 50 dB, min Inverting or Non-inverting (selectable) Channel Characteristics Frequency Response ±1.5 dB, in band; ±0.5 dB, 36 MHz BW; ±0.75 dB, 72 MHz BW Spurious Response <-50 dBC Group Delay, max 0.0035 ns/MHz2 parabolic; 0.025 ns/MHz linear; 1 ns ripple Synthesizer Characteristics Frequency Accuracy ± 1.0 ppm internal reference (±0.01 ppm, option H) Frequency Step 1 MHz (125 kHz, option X) 10 MHz In/Out Level 3 dBm ± 3dB Phase Noise @ F (Hz)> 100 1K 10K 100K 1M dBC/Hz -75 -75 -85 -100 -120 Controls, Indicators Freq/Gain Selection Power; Alarm; Remote Remote Direct readout LCD; pushbutton switches or remote selection Green LED; Red LED; Yellow LED RS232C, 9600 baud Other RF Connectors Type F (female) IF Connectors BNC (female) 10MHz Connectors BNC (female), 50/75 (option E) Alarm/Remote Connector DB9, male - NO or NC contact closure on alarm Size 19 inch standard chassis 1.75”high X 16.0” deep Power 100-240 ±10% VAC, 47- 63 Hz, 25 watts max. Options E H L V Q T W8 X Connectors/Impedance External 10 MHz ref input & output w/ RF insertion High Stability (±0.01ppm) internal reference LNB Voltage, +24VDC, 0.4 amps SSPB Voltage, +24VDC, 2.5 amps RS485 Remote Interface PCB Temperature Ethernet M&C Rremote Interface 125 kHz Frequency Steps See Table 2.2 (Page 11) *+10˚C to +40˚C; Specifications subject to change without notice 2017-05A Manual, Rev B Page 4 12/03/08 1.3 Monitor and Control Interface A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS-232C, RS-422, or RS-485 - option Q) M&C Cable Diagram - Cross Technologies Frequency Converters Female DB-9 PC Com Port Male DB-9 2015/16/17 M&CPort 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 Connector: Rear panel, DB-9 male J10 Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 2017-05A Manual, Rev B Page 5 12/03/08 B) Status Requests Table 1.1 lists the status requests for the 2017-05A and briefly describes them. * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.1 2017-05A Status Requests Requests Command Syntax* Description Command Status {aaS1} Returns {aaS1bbbbccccdddeeffLMNOP} where: • bbbb = Tx frequency (bbbbbbb, option -X) 4 characters - standard (7 characters - Option-X) • cccc = Rx frequency (ccccccc, option -X) 4 characters - standard (7 characters - Option-X) • ddd = Tx gain (-10 to 30) • ee = Rx gain (00 to 50) • ff = Tx input level (10 to 40 => -10 to -40 dBm) • L = 0 - non-inverted Receiver; L = 1 - inverted • M = 0 - Receiver synth alarm • N = 0 - Transmitter synth alarm • O = 0 - Summary alarm • P = 0 - Transmit signal disabled (muted) External 10MHz (option -E) {aaS2} Returns {aaS2bcd} where: • b = 1 - External 10MHz selected • c = 1 - 10MHz inserted on upconverter RF (J5) • d = 1 - 10MHz inserted on downconverter RF (J2) LNB Current (option -L) {aaS3} Returns {aaS3bb} where: • bb = LNB current, range 00 to 50 (0 to 500 ma) SSPB Current (option-V) {aaS4} Returns {aaS4bbb} where: • bbb = SSPB current, range 000 to 250 (0 to 2500 ma) 2017-05A Manual, Rev B Page 6 12/03/08 C) Commands Table 1.2 lists the commands for the 2017-05A and briefly describes them. After a command is sent the 2017-05A sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where: { = start byte aa = address (RS-485 only option -Q) C = 1 character, either C (command) or S (status) N = 1-digit command or status number, 1 through 9 D = 1 character or more of data (depends on command) } = stop byte * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.2 2017-05A Commands Command Syntax* Description Set Transmitter Frequency {aaC1xxxx} where: • xxxx = 4 characters • Range: 0950 to 1525 MHz Set Transmitter Input Level {aaCIxx} where: • xx = 2 characters • Range: 10 to 40 (-10 to -40 dBm) Set Receiver Frequency {aaC2xxxx} where: • xxxx = 4 characters • Range: 0950 to 1525 MHz Set Transmit Gain {aaC3xxxx} where: • xxxx = 2 or 3 characters • Range: -25 to +15 in 1 dB steps Set Receiver Gain {aaC4xxx} where: • xx = 2 characters • Range: 00 to 50 (00 dB to 50 dB, in 1 dB steps) Enable Tx {aaCAx} where x =: • 0 to disable Tx signal • 1 to enable Tx signal External 10MHz (option E) {aaCEx} where x =: • 0 to disable External 10MHz ref signal • 1 to enable External 10MHz ref signal Insert 10MHz on UP RF (option E) {aaC5x} where x =: • 0 to disable 10MHz upconverter insertion on RF (J5) • 1 to enable 10MHz upconverter insertion on RF (J5) Insert 10MHz on DOWN RF (option E) {aaC6x} where x =: • 0 to disable 10MHz downconverter insertion on RF (J2) • 1 to enable 10MHz downconverter insertion on RF (J2) Downconverter Spectrum {aaC7x} where x =: • 0 for non-inverted • 1 for inverted Enable Remote # Just # sign Disable Remote {aaCR0}* {CR and zero} 2017-05A Manual, Rev B Page 7 12/03/08 1.4 Use Information A. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. B. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required. C. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. D. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used, when addressing this concern. E. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). F. Top Cover - There are no servicable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE RE-INSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2017-05A Manual, Rev B Page 8 12/03/08 2.0 Installation 2.1 Mechanical - The 2017-05A consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ± 12, +5, +24 VDC power supply provides power for the assemblies. The 2017-05A can be secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 2017-05A is assembled. POWER SUPPLY Figure 2.0 Model 2017-05A Mechanical Assembly 2017-05A Manual, Rev B Page 9 12/03/08 2.2 Rear Panel Input/Output Signals and Control Figure 2.1 shows the input and output connectors on the rear panel. AC1 - POWER IN AC input for switching power supply.100-240 ±10% VAC, 47-63 Hz. J2 - RF IN 950-1525 MHz input, -60 to -10 dBm, See Table 2.2. F1 - LNB FUSE (option -L) J1 - IF OUT 0.5A, Fast Blo, 1/4” Fuse; installing 140 MHz output, -10 to 0 dBm, See Table 2.2. fuse places +24 VDC, 0.4 Amps, max on the RF IN (J2 center pin). AC J10 - MONITOR AND CONTROL DB9 female connector. See Table 2.1. DOWNCONVERTER RF IN GND MONITOR AND CONTROL 10 MHZ REF OUTPUT IF OUT LNB FUSE F1 5 J2 DS8 F2 - SSPB FUSE (option -V) 2.5A, Fast Blo, 1/4” Fuse; installing fuse places +24 VDC, 2.5 amp, max on the RF OUT (J5 center pin). UPCONVERTER IF IN J3 J4 1 6 J18 - 10 MHz REF OUTPUT (option -E) 10 MHz reference output. 75 BNC female connector. J3 - 10 MHz EXT REF INPUT (Option -E) 10 MHz external reference input, 3 ± 3 dBm, 75 ohms, BNC female connector. 10 MHZ EXT REF INPUT 3 2 8 7 J10 J18 J1 DS8 - LNB ALARM LED (option -L) Lights yellow when +24 VDC LNB voltage is present on RF IN, J2, center pin. 4 9 VDC on RF RF OUT SSPB FUSE F2 VDC on RF J4 - IF IN 140 MHz input, -40 to -10 dBm in, See Table 2.2. DS7 DS7 - SSPB ALARM LED (option -V) Lights yellow when +24 VDC SSPB voltage is present on RF OUT, J5, center pin. J5 J5 - RF OUT 950-1525 MHz output, -35 to -15 dBm out, See Table 2.2. Figure 2.1 Model 2017-05A Rear Panel I/O’s 2017-05A Manual, Rev B Page 10 12/03/08 Tables 2.1 & 2.2 shows the input and output connectors on the rear panel. TABLE 2.1 J10 J10 Pinouts (RS-232C/422/485*) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed *Remote Serial Interface Interface: DB-9 Male Protocol: RS-232C (RS-232C/422/485 option -Q), 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit. TABLE 2.2 IF/RF IF/RF Connector Options Option ns Option IF RF STD BNC, 75 Type F, 75 B BNC, 75 BNC, 75 C BNC, 75 BNC, 50 D BNC, 50 BNC, 50 F Type F, 75 Type F, 75 J BNC, 50 Type F, 75 K BNC, 50 BNC, 50 M BNC, 50 Type N, 50 N BNC, 75 Type N, 50 2017-05A Manual, Rev B Page 11 12/03/08 2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators. DS3 - DOWN ALARM LED Red LED indicates downconverter alarm. DS1 - REMOTE LED Yellow LED indicates remote operation. DOWNCONVERTER LCD DISPLAY Display shows Up and Downconverter frequency in MHz and Gain in dB UPCONVERTER U F=1525 D F=1525 G=+00 G=+25 S1 - MENU/EXECUTE BUTTON Press this to get into Program mode and to execute any changes. MENU EXECUTE ALARM REMOTE DS6 - POWER LED Green LED indicates presence of DC power. POWER MUTE ALARM DS5 - UP MUTE LED Yellow LED indicates upconverter mute. DS2 - UP ALARM LED Red LED indicates upconverter alarm. S2 - VERT. TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode. Does not function in the normal display mode S3 - HORIZ. TOGGLE Horizontal toggle switch that controls which values are being adjusted. Does not function in the normal display mode Figure 2.2 Model 2017-05A Front Panel Controls and Indicators 2017-05A Manual, Rev B Page 12 12/03/08 2.4 Installation / Operation 2.4.1 Installing and Operating the 2017-05A, Upconverter Section 1.) Connect a -40 dBm to -10 dBm signal to IF In, J4 (Figure 2.1). 2.) Connect the RF OUT, J5, to the external equipment. 3.) Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel. 4.) Set the desired output frequency (See Section 2.5 Menu Settings). 5.) Set the input level (See Section 2.5 Menu Settings). 6.) Set the gain (See Section 2.5 Menu Settings). 7.) (option -V) To power the SSPB (+24 VDC, 2.5 amps max) from the 2017-05A install a 2.5 amp 1/4”fuse in F2. CAUTION!!! INSTALLING A FUSE IN F2 PUTS +24 VDC, 2.5 AMP POWER ON THE CENTER PIN AND MAY DAMAGE EQUIPMENT IF IMPROPERLY CONNECTED TO EQUIPMENT THAT CANNOT HANDLE THIS VOLTAGE OR HAS A DC PATH TO GROUND. 8.) Be sure DS6 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2). 2.4.2 Installing and Operating the 2017-05A, Downconverter Section 1.) Connect a -60 dBm to -10 dBm signal to RF In, J2 (Figure 2.1). 2.) Connect the IF OUT, J1, to the external equipment. 3.) Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel. 4.) Set the desired input frequency (See Section 2.5 Menu Settings). 5.) Set the gain to get an output level in the 0 to -20 dBm range (See Section 2.5 Menu Settings). 6.) (option L) To power the LNB (+24 VDC, 0.4 amps, max) from the 2017-05A install a 1 amp 1/4” fuse in F1. CAUTION!!! INSTALLING A FUSE IN F1 PUTS +24 VDC, 0.5 AMP POWER ON THE CENTER PIN AND MAY DAMAGE EQUIPMENT IF IMPROPERLY CONNECTED TO EQUIPMENT THAT CANNOT HANDLE THIS VOLTAGE OR HAS A DC PATH TO GROUND. 7.) 8.) Be sure DS6 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2). AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot. If a fuse continues to open, the power supply is most likely defective. 2017-05A Manual, Rev B Page 13 12/03/08 FUSE DRAWER SPARE FUSE DRAWER AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mm INPUT ~ 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 - 240 V~ Figure 2.3 Fuse Location and Spare Fuse 2017-05A Manual, Rev B Page 14 12/03/08 2.5 Menu Settings 2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (see Figure 2.4): Power Up Normal Display Menu 1 Menu 2 Menu 3 Menu 4 Menu 5 Menu 6 Menu 7 Menu 8 Menu 9 Menu 10 Menu 11 Menu 12 Menu 13 Menu 14 Up Frequency in MHz Up Input Lvl (Set from -45 to -15) Down Frequency in MHz Down Gain (set 0 to +50 for -10 to 0 dBm out range) Up Mute Set Unit to Remote Operation Set Downconverter Spectrum Sense Select External 10 MHz Ref (option E) Upconverter Reference Out (option E) Downconverter Reference Out (option E) Set RS-485 mode (option Q) Set RS-485 address (option Q) View PCB Temperature (option T) View LNB and/or SSPB Current (options L and/or V) Save Menu When go to end Alarm indications appear on the LEDs (see figure 2.2). All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the “Save Settings?” Menu. If this sequence is not followed, none of the changes will take effect. If programming is initiated and no operator action takes place for approximately 12 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over. 2017-05A Manual, Rev B Page 15 12/03/08 2.5.2 Power-On Settings NOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT'S PREVIOUS SETTINGS. When power is first applied, the LCD display goes through three steps. 1. The LCD goes black to show all segments are functioning. 2. The software version will be displayed. REV1.00 3. The present frequency and gain of the up and downconverter is shown. U F=1350 G=+00.0 D F=1250 G=+20.0 The unit is now operational and ready for any changes the operator may desire. 2.5.3 Control Switches 1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the Menu/Execute switch and completed by pressing the Menu/Execute switch. 2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor left or right. 3. Vertical Switch - This switch is mounted so its movement is vertical and has two functions: a. During frequency , gain, input level changes, the vertical movement will raise or lower the number in the direction of the arrows. b. For other functions such Mute on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 2017-05A Manual, Rev B Page 16 12/03/08 2.5.4 Frequency Changes At any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode or scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window. To change the FREQUENCY: Operate the Menu/Execute switch until you get to the menu item you want to change (see Figure 2.4 for the sequence of menu options). The following display is for changing the upconverter frequency: UP F = 1350 R Pressing the Up/Down switch down will toggle the display to: UP F = 1450 R By using the horizontal rocker switch the cursor can be moved left or right. UP F = 1450 R NOTE: CHANGES DO NOT TAKE PLACE ON FREQUENCY UNTIL YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE CHANGES. When the display indicates the value desired you can push the Menu/Execute switch to the next item: UP INLVL = -20 R NOTE: CHANGES TAKE PLACE ON LEVEL AND GAIN IMMEDIATELY BUT DO NOT GET SAVED UNTIL YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE CHANGES. OR you can scroll to “R”, push the Menu/Execute switch to get to: SAVE SETTINGS? YN Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to the : U F=1450 G=+00.0 D F=1250 G=+20.0 Figure 2.4 shows all the menu items and how to make changes. 2017-05A Manual, Rev B Page 17 12/03/08 2.5.5 Gain/Level Changes When you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you have made, scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window or do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode. 2.5.5.1 Upconverter Input Level To set the upconverter input level, first push the Menu/Execute switch until you get to the upconverter input level setting: Operate the Menu/Execute switch until you get to the menu item you want to change see Figure 2.4 for the sequence of menu options. The following display is for changing the upconverter input level. This is an important setting to optimize spurious and should be made as accurately as possible: UP INLVL = -20 R Pressing the Up/Down switch down will toggle the display digit selected until you have the desired level. NOTE: THE VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS WINDOW. UP INLVL = -10 R By using the horizontal rocker switch the cursor can be moved left or right . UP INLVL = -10 R When the display indicates the value desired you can push the Menu/Execute switch to the next item OR you can scroll to “R”, push the Menu/Execute switch to get to: SAVE SETTINGS? YN Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to the : U F=1450 G=+00.0 D F=1350 G=+20.0 Figure 2.4 shows all the menu items and how to make changes. 2017-05A Manual, Rev B Page 18 12/03/08 2.5.5.2 Downconverter Gain To set the downconverter gain, first push the Menu/Execute switch to get to the gain setting: Operate the Menu/Execute switch until you get to the menu item you want to change see Figure 2.4 for the sequence of menu options. The following display is for changing the downconverter gain. This is an important setting to optimize spurious and should be made as accurately as possible to provide an output in the -10 to 0 dBm level range: DN G = +30.0 R Pressing the Up/Down switch to change the level in 1 or 10 dB steps. By using the horizontal rocker switch the cursor can be moved left or right. Pressing the Up/Down switch down will toggle the display digit selected until you have the desired gain. NOTE: THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS. HOWEVER, THE VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS WINDOW. When the display indicates the value desired you can push the Menu/Execute switch to the next item OR you can scroll to “R”, push the Menu/Execute switch to get to: SAVE SETTINGS? YN Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to the : U F=1450 G=+00.0 D F=1350 G=+30.0 Figure 2.4 shows all the menu items and how to make changes. 2.5.5.3 Alarm Indications An alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock. 2017-05A Manual, Rev B Page 19 12/03/08 ON POWER UP REV 1.00 Power Up NORMAL DISPLAY Normal Display U F = 1450 G = +00.0 D F = 1350 G = +25.0 PUSH BUTTON PUSHING MENU/EXECUTE SEQUENCE UP F = 1450 Menu 1 Up Frequency R SCROLL <> SCROLL R UP INLVL = -20 Menu 2 Up Input Level (Set from -40 to -10) DN F = 1350 R DN G = +25.0 OFF R OTHER? SCROLL REMOTE OFF Menu 7 Set Downconverter Spectrum Sense DNSPECTRUM NON Menu 8 Select 10 MHz Reference INT, EXT, or AUTO (option -E) INT REF Menu 9 Select Upconverter Reference Out (option -E) UP REF OUT Menu 10 Select Downconverter Reference Out (option -E) DN REF OUT Menu 11 Reference Offset (option -E) FREQ ADJUST Offset = +000 R Menu 12 Set Remote Mode (option -Q) RS 485 R R R R R SAVE SETTINGS? PUSH BUTTON SCROLL <> SCROLL LNB DC = 0.32 A SSB DC = 1.86 A PUSH BUTTON SCROLL <> SCROLL R PUSH BUTTON SCROLL <> SCROLL ADDRESS = 00 PUSH BUTTON SCROLL <> SCROLL OFF PUSH BUTTON SCROLL <> SCROLL OFF PUSH BUTTON SCROLL <> SCROLL OFF PUSH BUTTON SCROLL <> SCROLL R PUSH BUTTON SCROLL <> SCROLL Menu 14 View LNB current and SSPB current (options -L and -V) PUSH BUTTON SCROLL <> Y N Menu 7 Set Unit to Remote Operation Menu 13 Set RS-485 Address (option -Q) PUSH BUTTON SCROLL <> SCROLL Menu 6 For Other Settings (below) PUSH BUTTON SCROLL <> SCROLL UP MUTE Menu 5 Up Mute R PUSH BUTTON SCROLL <> SCROLL Menu 4 Down Gain (set 0 to +50 for -20 to 0 dBm out level) Save? When go to end SCROLL <> SCROLL Menu 3 Down Frequency PUSH BUTTON PUSH BUTTON BUTTON PUSH R PUSH BUTTON Y N SCROLL <> PUSH BUTTON Figure 2.4 Menu Display and Sequence 2017-05A Manual, Rev B Page 20 12/03/08 CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] 2017-05A Manual, Rev B Page 21 12/03/08 ">
Advertisement