Venmar 20/40/60-minute lighted push button Air Exchangers Accessory User guide

Add to my manuals
1 Pages

advertisement

Venmar 20/40/60-minute lighted push button Air Exchangers Accessory User guide | Manualzz

I

NSTALLATION AND

U

SER

G

UIDE FOR

20/40/60-

MINUTE

P

USH

-B

UTTON

T

IMER

V

ENMAR NO

. 03364

AND VÄN

EE

NO

. 03701

READ AND SAVE THESE INSTRUCTIONS

The illustrations in this document are generic; your push button appearance may be slightly different from the ones shown.

!

WARNING

Always disconnect the unit before making any connections. Failure in disconnecting power could result in electric shock or damage of the wall control or electronic module inside the unit.

Unplug the ventilation unit.

unit, as shown below. For more details, refer to the installation manual of the ventilation unit.

NOTE: To avoid miswiring, refer to the notes about the color of the wires taken on step

.

Cut a 2³/

8

” x 1³/

8

” hole in a wall, at a convenient location for the push button. Route a cable (type 22/4) for the push-button from the unit to this hole.

See figure at right.

NO C NC I OC OL Y R G B

20/40/60-MINUTE PUSH-BUTTON TIMER

REAR VIEW

A

CTUAL

MODELS

OL OC I

VE0277A

Ø 3/16", typ.

Temporarily place the push button over the hole and mark both mounting screw hole positions.

holes (3/16” Ø) in wall and insert the wall anchors (included).

VC0134A

E

ARLIER

MODELS

PC BOARD

B

G

R

Y

OL

OC

I 3

2

1

5

4

7

6

9

8

J3

J1

NOTE: Although this is a 4-wire cable, only 3 of them will be used for connection.

Strip the end of 3 wires. Connect wires to the terminals, regardless of the wire color: one wire to “OL’’, another one to

“OC’’ and a last one to “I’’. Note which wire color has been

chosen for each terminal. See illustration below.

20/40/60-MINUTE PUSH-BUTTON TIMER

REAR VIEW

First wire Second wire

Fourth wire

(NOT USED)

VE0279A

OL OC I

Third wire

VE0278A

1 4 7

2 5 8

3 6 9 push button.

High speed activation times are in multiples of 20 minutes.

• Within two seconds, push once for

20-minute, twice for 40-minute, or three times for 60-minute activation.

Indicator then lights up and the system exchanges air at high speed.

• Every five seconds, the indicator light flashes once to indicate a 20-minute selection, twice for a 40-minute and three times for a 60-minute selection.

• Push once more to stop activation.

Unit then returns to its to previous

VC0136 setting.

OL OC I

20/40/60-MINUTE PUSH-BUTTON TIMER

REAR VIEW

VC0135

20256 rev. 01

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement