Venmar 20/40/60-minute lighted push button Air Exchangers Accessory User guide
Add to my manuals1 Pages
Venmar 20/40/60-minute lighted push button helps you manage your home ventilation system with ease. Activate high-speed air exchange for 20, 40, or 60 minutes with simple button presses. The indicator light flashes to confirm your selection. To stop early, simply press the button again, and the system will resume its previous settings. Installation requires a 2 3/8" x 1 3/8" hole and basic electrical connections.
advertisement
I
NSTALLATION AND
U
SER
G
UIDE FOR
20/40/60-
MINUTE
P
USH
-B
UTTON
T
IMER
V
ENMAR NO
. 03364
AND VÄN
EE
NO
. 03701
READ AND SAVE THESE INSTRUCTIONS
The illustrations in this document are generic; your push button appearance may be slightly different from the ones shown.
!
WARNING
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electric shock or damage of the wall control or electronic module inside the unit.
Unplug the ventilation unit.
unit, as shown below. For more details, refer to the installation manual of the ventilation unit.
NOTE: To avoid miswiring, refer to the notes about the color of the wires taken on step
.
Cut a 2³/
8
” x 1³/
8
” hole in a wall, at a convenient location for the push button. Route a cable (type 22/4) for the push-button from the unit to this hole.
See figure at right.
NO C NC I OC OL Y R G B
20/40/60-MINUTE PUSH-BUTTON TIMER
REAR VIEW
A
CTUAL
MODELS
OL OC I
VE0277A
Ø 3/16", typ.
Temporarily place the push button over the hole and mark both mounting screw hole positions.
holes (3/16” Ø) in wall and insert the wall anchors (included).
VC0134A
E
ARLIER
MODELS
PC BOARD
B
G
R
Y
OL
OC
I 3
2
1
5
4
7
6
9
8
J3
J1
NOTE: Although this is a 4-wire cable, only 3 of them will be used for connection.
Strip the end of 3 wires. Connect wires to the terminals, regardless of the wire color: one wire to “OL’’, another one to
“OC’’ and a last one to “I’’. Note which wire color has been
chosen for each terminal. See illustration below.
20/40/60-MINUTE PUSH-BUTTON TIMER
REAR VIEW
First wire Second wire
Fourth wire
(NOT USED)
VE0279A
OL OC I
Third wire
VE0278A
1 4 7
2 5 8
3 6 9 push button.
High speed activation times are in multiples of 20 minutes.
• Within two seconds, push once for
20-minute, twice for 40-minute, or three times for 60-minute activation.
Indicator then lights up and the system exchanges air at high speed.
• Every five seconds, the indicator light flashes once to indicate a 20-minute selection, twice for a 40-minute and three times for a 60-minute selection.
• Push once more to stop activation.
Unit then returns to its to previous
VC0136 setting.
OL OC I
20/40/60-MINUTE PUSH-BUTTON TIMER
REAR VIEW
VC0135
20256 rev. 01
advertisement