QT-DK-16_26-2 Hard Code Toggle for Fail Secure

QT-DK-16_26-2 Hard Code Toggle for Fail Secure
≡ SECURITRON QUICK TIP≡
QUICK TIP NUMBER:
QT-DK-16/26-2
PRODUCT:
DK-16 or DK-26 Series Digital Keypads
DESCRIPTION:
It is possible to use the Digital Keypad’s Hard
Code function to provide manual building opening and
closing at this door. This will allow the customer to unlock the door (during
business hours for example) and then relock it manually (at close of business for
example). This is called a “Toggle Mode”. Once the door is relocked the standard
User Codes will allow standard after hours entry.
If you intend to use this application you will need to verify that the lock is rated
for continuous duty. The first thing that you must do is wire the Digital Keypad as
shown below. You will then need to program at least one User Code and the Hard
Code. While in the Program Mode you will also need to press in code 75. Code 75
will activate the Hard Code Toggle function. Please note that the Door Bell
Function or any other function involving the programmable relay will not be
available once this function is programmed.
GRN YEL RED BLU WHT BLK GRY BRN BGE ORG PNK VIO
AC IN
F
+
-
DC IN/OUT
From DC
POWER
SUPPY
DK-16/26
SRC REX UCDHCD NCX CX NOX NC2 C2 NO2 NC1 C1 NO1
TO FAIL SECURE
LOCK
Wiring a DK-16 or DK-26 for HARD CODE Openings & Closings
(with a Fail Secure Lock)