BR481

BR481
Quality-Assured
Motors For Every
Nuclear Application
Why Baldor?
Customer Preference
90%
2000
20%
1985
94%
2003
95.5%
2007
50%
1990
The percentages shown reflect
results of studies conducted
Percentage of research studies in which
in which Baldor was chosenBaldor
as “most
preferred”
was chosen
most preferred.
For nearly 100 years, Baldor has strived to provide customers
with the best value and reliability in industrial electric motors.
That kind of dedication results in satisfied customers and a
strong preference for Baldor•Reliance motors, as the chart
above shows. Here are just a few of the things Baldor does to
earn such recognition:
Baldor offers the industry’s broadest line of stock
products. Save valuable time with just one call to Baldor. We
offer more than 10,000 stock motors, drives and gearboxes.
Energy-efficiency leader. Baldor began lowering the energy
consumption of our motors in the 1920’s, long before others
were even talking about it. Today, Baldor’s expansive line of
Premium Efficiency motors extends from 1 through 15,000
Hp. Baldor’s motors offer customers the highest overall
efficiency levels in the industry, including Baldor•Reliance
Super-E® (1 through 500 Hp) motors that exceed NEMA
Premium® efficiencies.
Industry’s
shortest lead
times/Flexible
manufacturing.
Baldor has the
industry’s shortest
lead times on
custom Motors.
Our unique LEAN
FLEX FLOW™
manufacturing
process lets us
produce any order in any quantity, quickly and efficiently.
Industry’s best access to information. Only Baldor offers
customers so many choices for product information with a
wide variety of catalogs and product brochures, the Baldor
Web site at www.baldor.com, or you may talk to a Baldor
customer service person at one of our sales offices.
Table of Contents
Subject Page
Features and Specifications
Nuclear Quality Assurance
Nuclear-class Insulation Systems
Above NEMA Capabilities
Construction and Design Characteristics
Motor Dimensions
Baldor products are available
at more locations than any
other brand. Our 35 district
offices across North America and
offices around the world, offer
immediate availability of
Baldor products and support to
thousands of customers.
Continuous innovation to improve reliability. Baldor leads
the motor industry in applying new technologies to improve
motor reliability. Recent improvements to the line of Severe
Duty motors are further proof that Baldor is the leader in
motors for process industry applications.
www.baldor.com
1-2
3
4
5
6-7
8-9
The Widest Selection
Of World-Class Motors
For Nuclear Applications
For over 90 years, the Reliance brand name has been
synonymous with reliability. Reliance nuclear motor designs
have been field-proven around the world in commercial nuclear
utilities and radioactive waste facilities with the most stringent
requirements. Our nuclear motors have proven themselves in
type test after type test.
As a leading global manufacturer of high-quality motors, Baldor
offers the widest selection of nuclear motors available from a
single source. Our product line encompasses over 250,000
ratings, types, styles, and sizes – from fractional through
15,000 HP – including AC motors designed to run with the most
advanced adjustable speed technology.
In addition to continuous-duty, three-phase, squirrel-cage AC
induction motors, we offer a full range of specialty motors and
specialized construction features, including:
•
•
•
•
Intermittent duty
Vertical hollow shaft (Above NEMA)
Specialized mounting
NEMA Premium® Efficiency electrical designs
Our capabilities extend to researching and developing
customized design solutions for critical applications. From
standardized to highly-engineered motors, we offer solutions for
virtually every ¼ HP to 15,000 HP nuclear motor requirement.
There are Reliance-brand nuclear motors driving pumps, fans,
compressors, and motorized valve actuators in nuclear power
plants across the United States, Canada, Europe, and Asia.
Also, Reliance nuclear motors support industrial operations,
such as nuclear waste cleanup and nuclear fuel reprocessing
procedures. When you chose Reliance nuclear motors, you
can be sure that every motor component, from the motor
hardware to the rotor and stator, will be 100% in compliance
with your specification and the requirements of the IEEE and
NUREG standards governing nuclear power plants.
Our nuclear motors are designed and manufactured to meet
the specific requirements of your environment, including:
Mild or Harsh Environment Qualification
IEEE 323, 1974, 1983
IEEE 334, 1974, 1994
IEEE 344, 1975, 1987
IEEE 11 7
IEEE 429
NUREG 0588 REV1
Quality Assurance
ISO 9001
10CFR50, Appendix B
ASME/ANSI NQA-1
CSAZ299.1
ANSI N45.2
10CFR21
Unlimited Performance
Whether you are operating in a Class 1E Safety-Related Harsh
or Mild Environment, or require radiation-resistant motors for
operation in a non-Class 1E commercial or industrial application,
Baldor has the motor that you require. We offer a comprehensive
selection of motors to meet your specifications.
www.baldor.com
1
Other Application-Specific Requirements
Mild Environment Motors
Reliance nuclear motors are designed to meet the specific
requirements found in specifications developed by nuclear
power plants and nuclear fuel reprocessing facilities. Each
specification is reviewed to determine normal and extraordinary
operating and environmental conditions, radiation exposure
levels, and LOCA (Loss of Coolant Accident) or other incident
environments. This information is provided to Design
Engineering to insure that the motor for the specific application
is sized and designed to meet all of the environmental and
operating conditions over the qualified life (40 years in most
power plants) of the motor.
Baldor offers a line of Class 1E motors in NEMA and most
IEC frame sizes that meet the IEEE 334-1994 definition for
a Mild Environment Product, with a total integrated radiation
dosage of < 1 X 104 Rads over a 40-year Design Life. These
motors have a Class H insulation system with VPI encapsulated
windings for extended thermal life. Standard features include
Severe Duty construction, Neoprene gaskets and seals, and
a non-metallic, low-loss fan design to reduce friction and
windage losses. A wide range of modifications and accessories
are available.
When required, Seismic Response Data and Curves are
provided by the nuclear facility to enable Engineering to
mechanically design a motor that will withstand the earthquake
stresses that the facility may be subject to. A Seismic Analysis,
either static or dynamic, is then performed to determine that
the design will meet the specified requirements. The analysis
performed meets the requirements of IEEE 344-1975, 1987.
These motors are completely manufactured and tested under
our 10CFR50, Appendix B Nuclear QA program. Available
software documents include a Seismic Analysis, Certificate of
Compliance, Routine Test Report, and a Mild Environmental
Qualification (EQ) Report.
Harsh Environment Motors
Reliance nuclear insulation systems, both the type H/RH
random wound and the F-RBI form wound systems, have been
qualified by rigorous accelerated life testing under severe
high temperature conditions, high humidity tests, accelerated
radiation endurance testing, and mechanical stress testing.
These qualification tests were conducted on both “motorette”
components and on complete motors. Based on the results
of this testing, both of these insulation systems are qualified
for a total integrated radiation dosage of up to 2 X 108 Rads
over a 40-year life, with a 60-year life at reduced operating
temperatures.
It is the performance and results of this testing that form
the basis for the Environmental Qualification Report that is
prepared and submitted with each Class 1E Safety-Related
nuclear motor.
2
www.baldor.com
Unlimited Quality Assurance
Baldor uses advanced manufacturing techniques and
continuous quality improvement procedures to ensure worldclass standards of quality with the ultimate goal of customer
satisfaction. The ISO certification process and 10CFR50
Appendix B audits are an integral part of everything we do,
from motor design and manufacture through documentation
and post-order support.
As part of our long-standing commitment to the nuclear
industry, Baldor offers extensive in-house testing to
ensure consistent “to spec” performance. Comprehensive
documentation capabilities fully support the specification
requirements of every nuclear application, no matter how small.
Specialized engineering studies are also available.
Large AC vertical TEWAC pump motor
Quality Control Checklist for Nuclear Motors
• All critical components are 100% inspected and
dimensionally checked against parts drawings, with all
measurements recorded.
• Samples of all materials such as wire, insulation, and
fasteners are destructively tested.
• Every manufacturing step is verified and recorded.
• Processes such as dip and bake and VPI are qualitycontrolled.
• Resins and varnishes are tested daily or before each
application.
• Ovens are calibrated, with baking times and temperatures
recorded.
Horizontal fabricated frame motor for
large pump applications
Horizontal cast iron motor for belted
fan applications
www.baldor.com
3
Ground Insulation
Turn Insulation
Strand Insulation
Film
Copper
Conductor
Class F Type RBI Form
Wound Insulation System
For Medium To High Voltage
Applications From 460-6,900 Volts
•
•
•
“Green” coils are surge tested per IEEE 522
to verify the avoidance of turn-to-turn shorts.
After VPI, stators are immersion tested per
IEEE 429, to ensure underwater performance.
Systems must demonstrate the ability
to withstand surges as high as 0.2 microsecond rise time.
Reliance Class F Type RBI Form Wound VPI sealed insulation systems
are tested and proven to meet the most stringent application requirements,
including IEEE 429 and nuclear Class 1E service.
Class H Type RH Random
Wound Insulation System
Top Wedge
Center Wedge
(Mid Stick)
Copper Wire
For Low Voltage
Applications Up To 600 Volts
•
•
•
•
•
Coil heads are laced and taped.
Lead connections are brazed and insulated.
Varnish resists high temperatures and high radiation.
Stator is dipped and baked three times, while
being rotated 180° between dips, to ensure full,
even coverage of coil heads.
The lead cable used has the same thermal
and radiation rating as the insulation system.
Slot Liner
Iron Core
Cross-Sectional View
Insulation Bonded to Copper
Copper
Typical Wire
Reliance Class H Type RH Random Wound insulation
systems are qualified for nuclear Class 1E service.
4
www.baldor.com
Baldor Above NEMA Motor Capabilities Overview
The reach of Baldor’s Above NEMA Motor product offering is vast. It
extends well beyond NEMA frames to ratings as high as 15,000 Hp
and as low as 300 RPM. This includes an extensive range of proven
cast iron and fabricated steel motors well suited for both General
Purpose and nuclear service applications.
Note the following charts which apply to motors meeting these NEMA
standards:
•650% Inrush current
•Equal or greater than NEMA, Part 20 design torques (as
described by NEMA for Above NEMA Motors)
•Standard NEMA voltage for each horsepower rating
•Minimum 90% Reduced Voltage Start
•NEMA specified (or less) load inertia applied to the motor shaft
•Inverter powered capabilities limited to Variable Torque loads
•Altitude below 3300 feet (above sea level)
•Operating ambient of 40°C (or lower)
•Horizontal foot mounted
•Centrifugal loads
•Direct coupled
The list of Baldor•Reliance Custom nuclear motor design capabilities
and features is even more impressive. Please contact a Baldor office
for details.
Enclosures: TEFC & TEAAC
2
4
6
8
3600 1800 1200 900
150
200
250
300
350
400
450
500
600
700
800
900
1000
1250
1500
1750
2000
2250
2500
2750
3000
3500
4000
4500
5000
6000
7000
8000
9000
10000
12000
15000
10
720
12
600
14
514
16
450
18
400
Enclosures: ODP, WPI, WPII, TEWAC & TEFV
20
360
22
327
24
300
2
4
6
8
3600 1800 1200 900
150
200
250
300
350
400
450
500
600
700
800
900
1000
1250
1500
1750
2000
2250
2500
2750
3000
3500
4000
4500
5000
6000
7000
8000
9000
10000
12000
15000
Cast Frames
Fabricated Steel Frames
Important Notes:
• Fabricated frames will be TEAAC enclosure.
• In many cases, fabricated frames utilize an enhanced cooling blower package to reduce noise levels.
10
720
12
600
14
514
16
450
18
400
20
360
22
327
24
300
Cast Frames
Fabricated Steel Frames
Important Notes:
• Application conditions outside of “NEMA” standards may move a rating to a different frame size.
• 1750 Hp to 2500 Hp 3600 RPM will normally be a cast frame rating, unless there is a requirement
for “stiff shaft” design.
• Enhanced cooling blower systems (provided on the motor) may be required at the top end of a frame
size.
www.baldor.com
5
Standard Motor Construction - NEMA Frame Sizes
Class 1E Safety Related Motor Family
Harsh Environment
HP Range - Standard
.25-.75
.25-2.0
Mild Environment
.50-250
.25-.75
.25-2.0
.50-250
48/56
143T-145T
182T-449T
Electrical Features
NEMA Frame Sizes
48/56
143T-145T
182T-449T
Premium Efficiency Winding Designs (XE)
S
S
S
S
S
S
Radiation-resistant Insulation System
S
S
S
–
–
–
Class H Insulation System
–
–
–
S
S
S
Multiple Dip & Bake Process
S
S
S
–
–
–
VPI Encapsulated Windings
–
–
–
S
S
S
Class B Temperature Rise @ 1.0 SF
S
S
S
S
S
S
Class F Temperature Rise @ 1.15 SF
S
S
S
S
S
S
Inverter Spike Resistant Insulation System
S
S
S
S
S
S
1.15 Service Factor
S
S
S
S
S
S
Mechanical Features
6
NEMA Frame Sizes
48/56
143T-145T
182T-449T
48/56
143T-145T
182T-449T
TEFC-XT or TENV-XT Enclosure
S
S
–
S
S
–
TEFC-XT Enclosure
–
–
S
–
–
S
Steel Frame, Cast iron endplates, steel fan cover
S
–
–
S
–
–
Cast Iron Frame, Cast iron endplates & fan cover
–
S
S
S
S
Plated Steel Conduit Box
S
–
–
S
–
–
Cast Iron Conduit Box
–
S
S
–
S
S
Viton Gaskets
S
S
S
–
–
–
Neoprene Gaskets
–
–
–
S
S
S
Bronze External Cooling Fan
S
S
S
–
–
–
Non-metallic External Cooling Fan
–
–
–
S
S
S
Double-Shielded Ball Bearings
S
S
–
S
S
–
Open Ball Bearings - PLS
–
–
S
–
–
S
Grease Inlet with Screw-in Plug
S
S
–
S
S
–
Grease Inlet with Tube Extension & grease fitting
–
–
S
–
–
S
Grease Outlet with Screw-in Plug
S
S
–
S
S
–
Grease Outlet with Tube Extension and Auto Relief
–
–
S
–
–
S
Chevron SRI-2 or Exxon Polyrex EM Grease
S
S
S
S
S
S
Stainless Steel Nameplate
S
S
S
S
S
S
Shaft Slinger, Lip Seal
S
S
–
S
S
–
Shaft Slinger, Steel
–
–
S
–
–
S
Automatic, Stainless Steel T-Drain
S
S
S
S
S
S
Zinc-plated Hex-hd Hardware
S
S
S
S
S
S
Carbon Steel Shaft Material
S
S
S
S
S
S
Internal Epoxy Paint
S
S
S
S
S
S
External Epoxy Paint, Blue-green
S
S
S
S
S
S
www.baldor.com
Typical Design Characteristics - Above NEMA
Class 1E Safety Related Motor Family
HP Range
Speed Range
Horizontal
Vertical
200 - 15,000
250 - 8,000
300 - 3600 RPM
300 - 3600 RPM
Electrical Characteristics
Frame Size Range
E5006 - 10840
V5008 - V10840
Voltage, Frequency
4,000 - 6,900 V, 50 & 60 Hz
4,000 - 6,900 V, 50 & 60 Hz
Service Factor
1.0, 1.15
1.0, 1.15
Torque Characteristics
NEMA Design B
NEMA Design B
Ambient Temperature
40 C
40 C
Windings
Form wound copper, non-hydroscopic epoxy resin,
multiple VPI process.
Form wound copper, non-hydroscopic epoxy resin,
multiple VPI process.
Winding Insulation Class
Class F, Type RBI
Class F, Type RBI
Temperature Rise
Class B @ 1.0 SF
Class B @ 1.0 SF
Thermal Protection
Winding RTD’s with auxiliary conduit box (typical);
other types available
Winding RTD’s with auxiliary conduit box (typical);
other types available
Testing
Routine Test and Report per IEEE 112 & NEMA MG
1-20.16.2
Routine Test and Report per IEEE 112 & NEMA MG
1-20.16.2
Lead System
Vulcanized ethylene propylene, ring-type lead lugs.
Vulcanized ethylene propylene, ring-type lead lugs.
Mechanical Features
Frame Size Range
E5006 - L10840
V5008 - V10840
Frame Dimensions
NEMA compliant, IEC compliance available on select
TEFC frame sizes only
NEMA Compliant
Enclosures
ODP, WPI, WPII, TEFC, TEAAC, TEWAC
ODP, WPI, WPII, TEAAC, TEWAC
Enclosure Construction
Cast Iron though G500 Frame. Fabricated steel on
larger motors.
Fabricated Steel
Rotor Construction
Fabricated Copper Bar
Fabricated Copper Bar
Foot Mounting Holes
Multiple holes on specified frame sizes
N/A
Nameplate
Stainless Steel
Stainless Steel
Slingers & Seals
Shaft Slinger, Steel
Shaft Slinger, Steel
Gaskets/Elastomers
Viton
Viton
Hardware
Grade 5, U.S. Standard, zinc dichromate plated,
Hex-head
Grade 5, U.S. Standard, zinc dichromate plated,
Hex-head
Grounding
Ground lug in conduit box, grounding pad on frame.
Ground lug in conduit box, grounding pad on frame.
External Cooling Fan
Bronze (TEFC & certain TEAAC designs)
N/A
Internal Cooling Fan
Bronze
Bronze
Bearings
Anti-friction (grease lubricated) or sleeve (oil ring or
flooded lubricated)
Various configurations depending upon thrust
requirements and application.
Lubricants
Chevron SRI-2 or Exxon Mobile Polyrex EM Grease
/ DTE oils
Chevron SRI-2 or Exxon Mobile Polyrex EM Grease
/ DTE oils
Balance
Standard Balance exceeds NEMA MG1
Standard Balance exceeds NEMA MG1
Shaft Material
Cold Rolled Steel, AISI 1040 Class I
Cold Rolled Steel, AISI 1040 Class I
Paint
Surface preparation (SSPC-SP-6), primer (SSPCSP-1), top coat (Alkyd Enamel)
Surface preparation (SSPC-SP-6), primer (SSPCSP-1), top coat (Alkyd Enamel)
Noise
Varies with design, complies with NEMA MG1. Low
noise options available.
Varies with design, complies with NEMA MG1. Low
noise options available.
www.baldor.com
7
FRAMES 250T THRU 440T
Frames 182T thru 445TS – NEMA Ratings
P
AB
C
LX
(8)
BS
N
AC
T
PX
(8)
O
U
AF
AAX
NPT
(8)
D
V
K
3/8–16
GROUND SCREW HOLE
SUPPLIED ONLY
WHEN REQUESTED
EV
2XF
BA
N-W
AA
NPT
J
G
E
H DIA.
2E
2F
A
B
Dimensions
TEFC-XT - Three Phase - Cast Iron Construction
Totally Enclosed Fan Cooled - NEMA 182T-445TS - Foot Mounted
Frame
Cast Iron Conduit Box
Aux C/box (2)
Size
A
D
E
H
O
P
T
BA
C
BS
B
AA
AB
AC
AF AAX LX
PX
(1)
182T 9.00 4.50 3.75 0.44 9.88 9.50 2.00 2.75 1.00 8.44 6.59 2.12 0.75 4.00 7.06 15.62 2.75 7.00
L182T 9.00 4.50 3.75 0.44 9.88 9.50 2.00 2.75 1.00 8.44 6.59 2.12 0.75 4.00 7.06 15.62 2.75 7.00
184T 9.00 4.50 3.75 0.44 9.88 9.50 2.00 2.75 1.00 8.44 6.59 2.12 0.75 4.00 7.06 15.62 2.75 7.00
L184T 9.00 4.50 3.75 0.44 9.88 9.50 2.00 2.75 1.00 8.44 6.59 2.12 0.75 4.00 7.06 15.62 2.75 7.00
213T 10.50 5.25 4.25 0.44 11.25 11.00 2.00 3.50 1.00 9.31 7.56 2.12 0.75 4.00 7.06 17.12 3.50 8.50
L213T 10.50 5.25 4.25 0.44 11.25 11.00 2.00 3.50 1.00 9.31 7.56 2.12 0.75 4.00 7.06 17.12 3.50 8.50
215T 10.50 5.25 4.25 0.44 11.25 11.00 2.00 3.50 1.00 9.31 7.56 2.12 0.75 4.00 7.06 17.12 3.50 8.50
L215T 10.50 5.25 4.25 0.44 11.25 11.00 2.00 3.50 1.00 9.31 7.56 2.12 0.75 4.00 7.06 17.12 3.50 8.50
254T 12.50 6.25 5.00 0.56 13.25 13.25 2.44 4.25 1.25 10.81 8.81 2.50 0.75 6.31 9.31 24.56 5.00 12.00
256T 12.50 6.25 5.00 0.56 13.25 13.25 2.44 4.25 1.25 10.81 8.81 2.50 0.75 6.31 9.31 24.56 5.00 12.00
284T 13.75 7.00 5.50 0.56 14.75 14.88 2.44 4.75 2.00 12.62 10.19 3.00 0.75 6.88 10.50 27.44 5.50 13.00
284TS 13.75 7.00 5.50 0.56 14.75 14.88 2.44 4.75 2.00 12.62 10.19 3.00 0.75 6.88 10.50 26.06 5.50 13.00
286T 13.75 7.00 5.50 0.56 14.75 14.88 2.44 4.75 2.00 12.62 10.19 3.00 0.75 6.88 10.50 27.44 5.50 13.00
286TS 13.75 7.00 5.50 0.56 14.75 14.88 2.44 4.75 2.00 12.62 10.19 3.00 0.75 6.88 10.50 26.06 5.50 13.00
324T 15.50 8.00 6.25 0.69 16.69 17.00 2.44 5.25 2.00 15.44 11.69 3.62 0.75 8.00 10.50 30.44 6.00 14.75
324TS 15.50 8.00 6.25 0.69 16.69 17.00 2.44 5.25 2.00 15.44 11.69 3.62 0.75 8.00 10.50 28.94 6.00 14.75
326T 15.50 8.00 6.25 0.69 16.69 17.00 2.44 5.25 2.00 15.44 11.69 3.62 0.75 8.00 10.50 30.44 6.00 14.75
326TS 15.50 8.00 6.25 0.69 16.69 17.00 2.44 5.25 2.00 15.44 11.69 3.62 0.75 8.00 10.50 28.94 6.00 14.75
364T 17.00 9.00 7.00 0.69 18.50 19.50 2.94 5.88 3.00 18.00 13.81 4.12 0.75 8.38 11.62 33.44 6.12 15.00
364TS 17.00 9.00 7.00 0.69 18.50 19.50 2.94 5.88 3.00 18.00 13.81 4.12 0.75 8.38 11.62 31.31 6.12 15.00
365T 17.00 9.00 7.00 0.69 18.50 19.50 2.94 5.88 3.00 18.00 13.81 4.12 0.75 8.38 11.62 33.44 6.12 15.00
365TS 17.00 9.00 7.00 0.69 18.50 19.50 2.94 5.88 3.00 18.00 13.81 4.12 0.75 8.38 11.62 31.31 6.12 15.00
404T 19.00 10.00 8.00 0.81 21.31 22.50 2.94 6.62 3.00 19.25 15.06 4.12 0.75 9.62 14.44 38.31 6.88 16.00
404TS 19.00 10.00 8.00 0.81 21.31 22.50 2.94 6.62 3.00 19.25 15.06 4.12 0.75 9.62 14.44 35.31 6.88 16.00
405T 19.00 10.00 8.00 0.81 21.31 22.50 2.94 6.62 3.00 19.25 15.06 4.12 0.75 9.62 14.44 38.31 6.88 16.00
405TS 19.00 10.00 8.00 0.81 21.31 22.50 2.94 6.62 3.00 19.25 15.06 4.12 0.75 9.62 14.44 35.31 6.88 16.00
444T 21.00 11.00 9.00 0.81 23.38 25.25 3.25 7.50 3.00 22.19 17.44 4.00 0.75 11.62 15.25 44.62 8.25 19.00
444TS 21.00 11.00 9.00 0.81 23.38 25.25 3.25 7.50 3.00 22.19 17.44 4.00 0.75 11.62 15.25 40.88 8.25 19.00
445T 21.00 11.00 9.00 0.81 23.38 25.25 3.25 7.50 3.00 22.19 17.44 4.00 0.75 11.62 15.25 44.62 8.25 19.00
445TS 21.00 11.00 9.00 0.81 23.38 25.25 3.25 7.50 3.00 22.19 17.44 4.00 0.75 11.62 15.25 40.88 8.25 19.00
Notes:
(1) All frames have mounting holes for dual mounting. Frame sized with the “L” designation are not suitable for conversion to F-2 mounting.
(2) Auxiliary terminal boxes supplied only when specified.
Dimensions are in inches.
Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing for the specific motor you require.
8
www.baldor.com
2F
2XF
–
–
5.50
5.50
–
–
7.00
7.00
–
10.00
–
–
11.00
11.00
–
–
12.00
12.00
–
–
12.25
12.25
–
–
13.75
13.75
–
–
16.50
16.50
4.50
4.50
–
–
5.50
5.50
–
–
8.25
–
9.50
9.50
–
–
10.50
10.50
–
–
11.25
11.25
–
–
12.25
12.25
–
–
14.50
14.50
–
–
Shaft and Key
N
N-W
U
V
Sq.
Lgth
Weight
Lbs.
3.00
3.00
3.00
3.00
3.62
3.62
3.62
3.62
4.12
4.12
5.00
3.62
5.00
3.62
5.62
4.12
5.62
4.12
6.25
4.12
6.25
4.12
7.50
4.50
7.50
4.50
8.94
5.19
8.94
5.19
2.75
2.75
2.75
2.75
3.38
3.38
3.38
3.38
4.00
4.00
4.62
3.25
4.62
3.25
5.25
3.75
5.25
3.75
5.88
3.75
5.88
3.75
7.25
4.25
7.25
4.25
8.50
4.75
8.50
4.75
1.125
1.125
1.125
1.125
1.375
1.375
1.375
1.375
1.625
1.625
1.875
1.625
1.875
1.625
2.125
1.875
2.125
1.875
2.375
1.875
2.375
1.875
2.875
2.125
2.875
2.125
3.375
2.375
3.375
2.375
2.50
2.50
2.50
2.50
3.12
3.12
3.12
3.12
3.75
3.75
4.38
3.00
4.38
3.00
5.00
3.50
5.00
3.50
5.62
3.50
5.62
3.50
7.00
4.00
7.00
4.00
8.25
4.50
8.25
4.50
0.250
0.250
0.250
0.250
0.312
0.312
0.312
0.312
0.375
0.375
0.500
0.375
0.500
0.375
0.500
0.500
0.500
0.500
0.625
0.500
0.625
0.500
0.750
0.500
0.750
0.500
0.875
0.625
0.875
0.625
1.75
1.75
1.75
1.75
2.38
2.38
2.38
2.38
2.88
2.88
3.25
1.88
3.25
1.88
3.88
2.00
3.88
2.00
4.25
2.00
4.25
2.00
5.62
2.75
5.62
2.75
6.88
3.00
6.88
3.00
86
91
116
121
135
145
175
185
335
345
475
475
490
490
590
590
630
630
865
859
890
884
1220
1211
1260
1251
1670
1654
1860
1844
FRAMES 445T THRU 449TS ABOVE NEMA RATINGS
Frames 445T thru L449TY above NEMA ratings
AB
C
AC
Y
N
P
T
V
O
AF
D (2)
U (3)
K
BA
N-W
2E
AA
B
G
E
J
BS
2F
H DIA.
A
Dimensions
TEFC-XT - Three Phase - Cast Iron Construction
Totally Enclosed Fan Cooled - Frames 445T-L449TY - Above NEMA Ratings - Foot Mounted
Cast Iron Conduit Box
Frame
A
D(2)
E
H
O
P
T
Y
BA
C
BS
Size
AA
AB
AC
AF
445T 21.00 11.00 9.00 0.81 23.62 25.25 3.25
–
7.50 4.00 23.44 18.19 7.00 44.63 8.25
445TS 21.00 11.00 9.00 0.81 23.62 25.25 3.25
–
7.50 4.00 23.44 18.19 7.00 40.87 8.25
447T 21.00 11.00 9.00 0.81 24.25 25.25 4.25 5.00 7.50 4.00 23.44 18.19 7.00 48.13 10.00
447TS 21.00 11.00 9.00 0.81 24.25 25.25 4.25 5.00 7.50 4.00 23.44 18.19 7.00 44.37 10.00
449T 21.00 11.00 9.00 0.81 24.25 25.25 4.25 5.00 7.50 4.00 23.44 18.19 7.00 53.13 12.50
449TS 21.00 11.00 9.00 0.81 24.25 25.25 4.25 5.00 7.50 4.00 23.44 18.19 7.00 49.37 12.50
L449T 22.00 11.00 9.00 0.81 24.25 27.25 4.25 12.00 16.00 4.00 23.38 18.12 6.50 60.13 4.50
L449TS 22.00 11.00 9.00 0.81 24.25 27.25 4.25 12.00 12.25 4.00 23.38 18.12 6.50 56.38 4.50
L449TY 22.00 11.00 9.00 0.81 24.25 27.25 4.25 12.00 16.00 4.00 23.38 18.12 6.50 60.13 4.50
Dimensions are in inches.
Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing for the specific motor you require.
B
2F
19.00
19.00
22.50
22.50
27.50
27.50
34.50
34.50
34.50
16.50
16.50
20.00
20.00
25.00
25.00
25.00
25.00
25.00
N
8.50
4.75
8.50
4.75
8.50
4.75
8.06
4.31
8.06
N-W
8.50
4.75
8.50
4.75
8.50
4.75
8.06
4.31
8.06
Shaft and Key
U
V
3.375 8.25
2.375 4.50
3.375 8.25
2.375 4.50
3.375 8.25
2.375 4.50
3.375 8.06
2.375 4.31
3.875 8.06
Sq.
0.875
0.625
0.875
0.625
0.875
0.625
0.875
0.625
1.000
Lgth
6.91
3.03
6.91
3.03
6.91
3.03
6.88
3.00
6.88
Weight
Lbs.
1860
1860
2275
2275
2650
2650
4000
4000
4000
Universal 143T thru 145T TEFC SXT
14.03
4.22
8.14
2.25
.06
2.78
.19 SQ. X
1.25 KEY
.8745
.8750
8.13
9.42
3.50
3.47
8 - .38 DIA. HOLES
1/4-20 UNC-2B
GROUND SCREW
HOLE. ONE ON
EACH SIDE
2.25
1.44
4.00
2.75
.30
5.50
6.49
7.87
www.baldor.com
9
Contact your nearest Baldor Sales Office at these
World Wide locations, or visit www.baldor.com
UNITED STATES
ARIZONA
PHOENIX
4211 S 43RD PLACE
PHOENIX, AZ 85040
PHONE: 602-470-0407
FAX: 602-470-0464
ARKANSAS
CLARKSVILLE
1001 COLLEGE AVE.
CLARKSVILLE, AR 72830
PHONE: 479-754-9108
FAX: 479-754-9205
CALIFORNIA
LOS ANGELES
6480 FLOTILLA
COMMERCE, CA 90040
PHONE: 323-724-6771
FAX: 323-721-5859
HAYWARD
21056 FORBES STREET
HAYWARD, CA 94545
PHONE: 510-785-9900
FAX: 510-785-9910
INDIANA
INDIANAPOLIS
5525 W. MINNESOTA STREET
INDIANAPOLIS, IN 46241
PHONE: 317-246-5100
FAX: 317-246-5110
NORTH CAROLINA
GREENSBORO
1220 ROTHERWOOD ROAD
GREENSBORO, NC 27406
PHONE: 336-272-6104
FAX: 336-273-6628
UTAH
SALT LAKE CITY
2230 SOUTH MAIN STREET
SALT LAKE CITY, UT 84115
PHONE: 801-832-0127
FAX: 801-832-8911
EL SALVADOR
RESIDENCIAL PINARES DE SUIZA
POL. 15 #44,
NVA. SAN SALVADOR, EL SALVADOR
PHONE: +503 2288-1519
FAX: +503 2288-1518
MIDDLE EAST & NORTH AFRICA
VSE INTERNATIONAL CORP.
P. O. BOX 5618
BUFFALO GROVE, IL 60089-5618
PHONE: 847 590 5547
FAX: 847 590 5587
IOWA
DES MOINES
1800 DIXON STREET, SUITE C
DES MOINES, IA 50316
PHONE: 515-263-6929
FAX: 515-263-6515
OHIO
CINCINNATI
2929 CRESCENTVILLE ROAD
WEST CHESTER, OH 45069
PHONE: 513-771-2600
FAX: 513-772-2219
WISCONSIN
MILWAUKEE
2725 SOUTH 163RD STREET
NEW BERLIN, WI 53151
PHONE: 262-784-5940
FAX: 262-784-1215
CHILE
LUIS THAYER OJEDA 166,
OF 402 - PROVIDENCIA
SANTIAGO, CHILE
PHONE: +56 2 816 9900
MARYLAND
BALTIMORE
6660 SANTA BARBARA RD.
SUITE 22-24
ELKRIDGE, MD 21075
PHONE: 410-579-2135
FAX: 410-579-2677
PANAMA
AVE. RICARDO J. ALFARO
EDIFICIO SUN TOWERS MALL
PISO 2, LOCAL 55
CIUDAD DE PANAMÁ, PANAMÁ
PHONE: +507 236-5155
FAX: +507 236-0591
MASSACHUSETTS
BOSTON
6 PULLMAN STREET
WORCESTER, MA 01606
PHONE: 508-854-0708
FAX: 508-854-0291
COLORADO
DENVER
3855 FOREST STREET
DENVER, CO 80207
PHONE: 303-623-0127
FAX: 303-595-3772
MICHIGAN
DETROIT
5993 PROGRESS DRIVE
STERLING HEIGHTS, MI 48312
PHONE: 586-978-9800
FAX: 586-978-9969
CONNECTICUT
WALLINGFORD
65 SOUTH TURNPIKE ROAD
WALLINGFORD, CT 06492
PHONE: 203-269-1354
FAX: 203-269-5485
MINNESOTA
MINNEAPOLIS
21080 134TH AVE. NORTH
ROGERS, MN 55374
PHONE: 763-428-3633
FAX: 763-428-4551
FLORIDA
TAMPA/PUERTO RICO/
VIRGIN ISLANDS
3906 EAST 11TH AVENUE
TAMPA, FL 33605
PHONE: 813-248-5078
FAX: 813-247-2984
MISSOURI
ST LOUIS
422 INDUSTRIAL DRIVE
MARYLAND HEIGHTS, MO 63043
PHONE: 314-298-1800
FAX: 314-298-7660
GEORGIA
ATLANTA
62 TECHNOLOGY DR.
ALPHARETTA, GA 30005
PHONE: 770-772-7000
FAX: 770-772-7200
ILLINOIS
CHICAGO
4 SAMMONS COURT
BOLINGBROOK, IL 60440
PHONE: 630-296-1400
FAX: 630-226-9420
KANSAS CITY
1501 BEDFORD AVENUE
NORTH KANSAS CITY, MO 64116
PHONE: 816-587-0272
FAX: 816-587-3735
NEW YORK
AUBURN
ONE ELLIS DRIVE
AUBURN, NY 13021
PHONE: 315-255-3403
FAX: 315-253-9923
© Baldor Electric Company
BR481
CLEVELAND
8929 FREEWAY DRIVE
MACEDONIA, OH 44056
PHONE: 330-468-4777
FAX: 330-468-4778
OKLAHOMA
TULSA
7170 S. BRADEN, SUITE 140
TULSA, OK 74136
PHONE: 918-366-9320
FAX: 918-366-9338
OREGON
PORTLAND
20393 SW AVERY COURT
TUALATIN, OR 97062
PHONE: 503-691-9010
FAX: 503-691-9012
PENNSYLVANIA
PHILADELPHIA
1035 THOMAS BUSCH
MEMORIAL HIGHWAY
PENNSAUKEN, NJ 08110
PHONE: 856-661-1442
FAX: 856-663-6363
PITTSBURGH
159 PROMINENCE DRIVE
NEW KENSINGTON, PA 15068
PHONE: 724-889-0092
FAX: 724-889-0094
TENNESSEE
MEMPHIS
4000 WINCHESTER ROAD
MEMPHIS, TN 38118
PHONE: 901-365-2020
FAX: 901-365-3914
TEXAS
DALLAS
3040 QUEBEC STREET
DALLAS, TX 75247
PHONE: 214-634-7271
FAX: 214-634-8874
HOUSTON
10355 W. LITTLE YORK RD.
SUITE 300
HOUSTON, TX 77041
PHONE: (281) 977-6500
FAX: (281) 977-6510
INTERNATIONAL SALES
FORT SMITH, AR
P.O. BOX 2400
FORT SMITH, AR 72902
PHONE: 479-646-4711
FAX: 479-648-5895
CANADA
EDMONTON, ALBERTA
4053-92 STREET
EDMONTON, ALBERTA T6E 6R8
PHONE: 780-434-4900
FAX: 780-438-2600
TORONTO
OAKVILLE, ONTARIO
2750 COVENTRY ROAD
OAKVILLE, ONTARIO L6H 6R1
PHONE: 905-829-3301
FAX: 905-829-3302
MONTREAL, QUEBEC
5155, J.A. BOMBARDIER
ST-HUBERT (QUÉBEC) CANADA
J3Z 1G4
PHONE: 514-933-2711
FAX: 514-933-8639
VANCOUVER,
BRITISH COLUMBIA
1538 KEBET WAY
PORT COQUITLAM,
BRITISH COLUMBIA V3C 5M5
PHONE 604-421-2822
FAX: 604-421-3113
WINNIPEG, MANITOBA
54 PRINCESS STREET
WINNIPEG, MANITOBA R3B 1K2
PHONE: 204-942-5205
FAX: 204-956-4251
AUSTRALIA
UNIT 3, 6 STANTON ROAD
SEVEN HILLS, NSW 2147, AUSTRALIA
PHONE: (61) (2) 9674 5455
FAX: (61) (2) 9674 2495
UNIT 8, 5 KELLETTS ROAD
ROWVILLE, VICTORIA, 3178 AUSTRALIA
PHONE: (61) (3) 9753 4355
FAX: (61) (3) 9753 4366
CHINA
160 SONG SHENG ROAD
SONGJIANG INDUSTRY ZONE
SHANGHAI 201613, CHINA
PHONE: +86 21 5760 5335
FAX : +86 21 5760 5336
GERMANY
DIESELSTRASSE 22
D-85551 KIRCHHEIM
MUNICH, GERMANY
PHONE: +49 89 90 5080
FAX: +49 89 90 50 8492
INDIA
14, COMMERCE AVENUE
MAHAGANESH COLONY
PAUD ROAD
PUNE - 411038
MAHARASHTRA, INDIA
PHONE: +91 20 25 45 27 17 / 18
FAX: +91 20 25 45 27 19
INDONESIA
TALAVERA OFFICE PARK,
28TH FLOOR, SUITE M18
JI. T.B. SIMATUPANG, KAV. 22-26
JAKARTA 12430, INDONESIA
PHONE: +62 21 7599 9879
FAX: + 62 21 7599 9878
ITALY
BALDOR ASR AG
SUCCURSALE DI MENDRISIO
VIA BORROMINI, 20A
CH-6850 MENDRISIO
SWITZERLAND
PHONE: 0041 91 640 99 50
FAX: 0041 91 630 26 33
SINGAPORE
18 KAKI BUKIT ROAD 3, #03-09
ENTREPRENEUR BUSINESS CENTRE
SINGAPORE 415978
PHONE: (65) 6744 2572
FAX: (65) 6747 1708
SWITZERLAND
POSTFACH 73
SCHUTZENSTRASSE 59
CH-8245 FEUERTHALEN
SWITZERLAND
PHONE: +41 52 647 4700
FAX: +41 52 659 2394
TAIWAN
1F, NO 126 WENSHAN 3RD STREET,
NANTUN DISTRICT,
TAICHUNG CITY 408
TAIWAN R.O.C
PHONE: (886) 4 238 04235
FAX: (886) 4 238 04463
UNITED KINGDOM
6 BRISTOL DISTRIBUTION PARK
HAWKLEY DRIVE
BRISTOL BS32 0BF U.K.
PHONE: +44 1454 850000
FAX: +44 1454 859001
VENEZUELA
AV. ROMA. QTA EL MILAGRO. URB.
CALIFORNIA NORTE
CARACAS, 1070
VENEZUELA
PHONE/FAX: +58 212 272 7343
MOBILE: +58 414 114 8623
JAPAN
DIA BLDG 802,
2-21-1 TSURUYA-CHO,
KANAGAWA-KU
YOKOHAMA, 221-0835, JAPAN
PHONE: 81-45-412-4506
FAX: 81-45-412-4507
MEXICO
LEON, GUANAJUATO
KM. 2.0 BLVD. AEROPUERTO
LEÓN 37545, GUANAJUATO, MÉXICO
PHONE: +52 477 761 2030
FAX: +52 477 761 2010
Baldor Electric Company
P.O. Box 2400
Fort Smith, AR 72902-2400 U.S.A.
Ph (479) 646-4711 • Fax (479) 648-5792
International Fax (479) 648-5895
www.baldor.com
Printed in U.S.A.
5/10 TCP 10,000