5RU SSPA DATASHEET
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
650W X-Band 5RU SSPA Chassis (requires 1RU power supply)
Teledyne Paradise Datacom has a rich history in the design
and production of Gallium Nitride (GaN) based SSPAs. Our
engineers utilize innovative linearization techniques that enable
GaN amplifiers to produce linear output power with the same
efficiency as tube based amplifier systems. A complete family
of Satcom amplifiers has been developed that cover S-Band
through Ku-Band.
GaN amplifiers have a superior set of mutually beneficial characteristics, including:
• Higher Output Power
• Greater Power-Added Efficiency
• High Reliability
These GaN amplifier modules are installed in a 5RU (8.75 inch
high) Chassis, which features a front panel display and five
fault condition LEDs that reflect some of the SSPA major fault
states. Local/Remote and Mute/Unmute LEDs show the current
control mode and mute state of the amplifier.
A full compliment of remote monitor and control of the amplifier
is available at the rear panel, including: RS-232/RS-485; Ethernet, with UDP and SNMP control; Web Browser TCP/IP; and
Discrete hardware (parallel port) signals.
Teledyne Paradise Datacom LLC
328 Innovation Blvd., Suite 100
State College, PA 16803 USA
Tel: (814) 238-3450
Fax: (814) 238-3829
PAGE 1 OF 8
www.paradisedata.com
FEATURES
• Extremely High Power
Density:
to 2.0 kW S-Band
to 1.6 kW X-Band
to 1.6 kW C-Band
to 1.0 kW Ku-Band
• Removable Fan Tray and
M&C Card Assembly
• Remote Communication
via RS232/485 or Ethernet
• RF Output Sample Port
• 20 dB RF Gain Adjustment
• 1RU N+1 Power Supply
• True RF Output Power
Measurement
• Built-in Maintenance
Switch Controller
OPTIONS
• Remote Control Panel
• L-Band Input operation
• Reflected Power Monitor
• Input Sample Port
• Exhaust Duct Adapters
• Redundant Systems
• Phase Combined Systems
Teledyne Paradise Datacom Ltd.
2&3 The Matchyns, London Road, Rivenhall End
Witham, Essex CM8 3HA United Kingdom
Tel: +44(0) 1376 515636
Fax: +44(0) 1376 533764
212887 REV G ECO 17995
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
Specifications, S-Band SSPAs
PARAMETER
Frequency Range
Output Power
Typical, Psat
Guaranteed minimum, PLinear 1
Power Requirements
Line Frequency
Line Power (Voltage)
(typical @ 220 VAC)
Receive Band Noise Power Density
NOTES
LIMITS
UNITS
Frequency selection “G”
Frequency selection “A”
Frequency selection “B”
1.750 to 2.120
2.020 to 2.120
2.200 to 2.300
GHz
GHz
GHz
HPAS5500ARXXXXXG
HPAS5600ARXXXXXG
HPAS5800ARXXXXXG
HPAS510KARXXXXXG
HPAS512KARXXXXXG
HPAS516KARXXXXXG
HPAS520KARXXXXXG
Psat / PLinear
57.0 (500) / 54.0 (250)
57.8 (600) / 54.8 (300)
59.0 (800) / 56.0 (400)
60.0 (1000) / 57.0 (500)
60.8 (1200) / 57.8 (600)
62.0 (1600) / 59.0 (800)
63.0 (2000) / 60.0 (1000)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
power factor
HPAS5500ARXXXXXG
HPAS5600ARXXXXXG
HPAS5800ARXXXXXG
HPAS510KARXXXXXG
HPAS512KARXXXXXG
HPAS516KARXXXXXG
HPAS520KARXXXXXG
.98
47 to 63
@ Psat / PLinear
2100 / 1500 (180 to 265)
2200 / 1700 (180 to 265)
2500 / 2000 (180 to 265)
4000 / 3500 (180 to 265)
4500 / 3700 (180 to 265)
5100 / 4100 (180 to 265)
7800 / 6500 (180 to 265)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
without optional filter
with optional filter
-95
-155
dBW / 4 KHz
dBW / 4 KHz
Hz
Note 1: PLinear = maximum output power at which third order intermodulation products < -25 dBc (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 dBc.
Specifications, C-Band SSPAs
PARAMETER
Frequency Range
Output Power
Typical, Psat
Guaranteed minimum, PLinear 1
Power Requirements
Line Frequency
Line Power (Voltage)
(typical @ 220 VAC)
Receive Band Noise Power Density
NOTES
LIMITS
UNITS
Frequency selection “L”
Frequency selection “H”
Frequency selection “C” 2
Frequency selection “A”
Frequency selection “B” 2
Frequency selection “D”
4.400 to 5.000
5.715 to 5.790
5.750 to 6.670
5.850 to 6.425
5.850 to 6.725
6.425 to 7.025
GHz
GHz
GHz
GHz
GHz
GHz
HPAC5300ARXXXXXG
HPAC5400ARXXXXXG
HPAC5650ARXXXXXG
HPAC5800ARXXXXXG
HPAC513KARXXXXXG
HPAC516KARXXXXXG
Psat / PLinear
54.8 (300) / 51.8 (150)
56.0 (400) / 53.0 (200)
58.1 (650) / 55.1 (325)
59.0 (800) / 56.0 (400)
61.1 (1300) / 58.1 (650)
62.0 (1600) / 59.0 (800)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
power factor
HPAC5300ARXXXXXG
HPAC5400ARXXXXXG
HPAC5650ARXXXXXG
HPAC5800ARXXXXXG
HPAC513KARXXXXXG
HPAC516KARXXXXXG
.98
47 to 63
@ Psat / PLinear
1500 / 1300 (180 to 265)
1800 / 1600 (180 to 265)
3300 / 2800 (180 to 265)
4000 / 3500 (180 to 265)
4200 / 3800 (180 to 265)
7800 / 7000 (180 to 265)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
without filter
-155
dBW / 4 KHz
Hz
Note 1: PLinear = maximum output power at which third order intermodulation products < -25 dBc (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 dBc.
Note 2: Output power decreases over the extended portion of the frequency range. Both Psat and PLinear de-rate by 1 dB from 5.85 to 5.75
GHz and from 6.425 to 6.725 GHz.
PAGE 2 OF 8
212887 REV G ECO 17995
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
Specifications, X-Band SSPAs
PARAMETER
Frequency Range
Output Power
Typical, Psat
Guaranteed minimum, PLinear 1
Power Requirements
Line Frequency
Line Power (Voltage)
(typical @ 220 VAC)
Receive Band Noise Power Density
NOTES
LIMITS
UNITS
Frequency selection “F”
Frequency selection “D”
Frequency selection “A”
7.10 to 7.40
7.70 to 8.40
7.90 to 8.40
GHz
GHz
GHz
HPAX5300ARXXXXXG
HPAX5400ARXXXXXG
HPAX5650ARXXXXXG
HPAX5800ARXXXXXG
HPAX513KARXXXXXG
HPAX516KARXXXXXG
Psat / PLinear
54.8 (300) / 51.8 (150)
56.0 (400) / 53.0 (200)
58.1 (650) / 55.1 (325)
59.0 (800) / 56.0 (400)
61.1 (1300) / 58.1 (650)
62.0 (1600) / 59.0 (800)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
power factor
HPAX5300ARXXXXXG
HPAX5400ARXXXXXG
HPAX5650ARXXXXXG
HPAX5800ARXXXXXG
HPAX513KARXXXXXG
HPAX516KARXXXXXG
.98
47 to 63
@ Psat / PLinear
1500 / 1300 (180 to 265)
2000 / 1700 (180 to 265)
3300 / 2800 (180 to 265)
4000 / 3500 (180 to 265)
7000 / 6000 (180 to 265)
8000 / 7000 (180 to 265)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
without optional filter
with optional filter
-85
-155
dBW / 4 kHz
dBW / 4 kHz
Hz
Note 1: PLinear = maximum output power at which third order intermodulation products < -25 dBc (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 dBc.
Specifications, Ku-Band SSPAs
PARAMETER
NOTES
LIMITS
UNITS
Frequency Range
Frequency selection “F”
Frequency selection “B”
Frequency selection “A”
Frequency selection “G”
12.75 to 13.25
13.75 to 14.50
14.00 to 14.50
14.75 to 15.25
GHz
GHz
GHz
GHz
HPAK5300ARXXXXXG
HPAK5400ARXXXXXG
HPAK5500ARXXXXXG
HPAK5600ARXXXXXG
HPAK5800ARXXXXXG
HPAK510KARXXXXXG
Psat / PLinear
54.8 (300) / 51.8 (150)
56.0 (400) / 53.0 (200)
57.0 (500) / 54.0 (250)
57.8 (600) / 54.8 (300)
59.0 (800) / 56.0 (400)
60.0 (1000) / 57.0 (500)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
Output Power
Typical, Psat
Guaranteed minimum, PLinear 1
Power Requirements
Line Frequency
Line Power (Voltage)
(typical @ 220 VAC)
Receive Band Noise Power Density2
power factor
HPAK5300ARXXXXXG
HPAK5400ARXXXXXG
HPAK5500ARXXXXXG
HPAK5600ARXXXXXG
HPAK5800ARXXXXXG
HPAK510KARXXXXXG
.98
47 to 63
@ Psat / PLinear
2000 / 1500 (180 to 265)
2500 / 1700 (180 to 265)
3000 / 2000 (180 to 265)
4000 / 3000 (180 to 265)
5000 / 3400 (180 to 265)
6000 / 4000 (180 to 265)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
-155
dBW / 4 kHz
Hz
Note 1: PLinear = maximum output power at which third order intermodulation products < -25 dBc (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 dBc.
Note 2: All Ku-Band SSPAs are fitted with a receive band reject bulkhead filter, standard. An optional pressure window is available.
PAGE 3 OF 8
212887 REV G ECO 17995
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
Common Electrical Specifications
PARAMETER
NOTES
LIMITS
UNITS
range
full band
full band (Extended C-Band)
full band (S-Band)
per 40 MHz
per 10 MHz (S-band)
0 °C to +50 °C
at constant temperature
0.1 dB resolution
55-75
± 1.0
± 1.5
± 0.75
± 0.3
± 0.3
± 1.0
± 0.25
20
dB
dB
dB
dB
dB/40 MHz
dB/10 MHz
dB
dB/24 hours
dB
At PLinear (Psat - 3 dB)
-25
dBc
@ rated PLinear
≤ 1.0
@ rated PLinear
@ rated PLinear
@ rated PLinear (S-Band)
-65
-50
-30
Extended C-Band
Output VSWR: Ku-Band with bulkhead filter
1.30:1
1.50:1
1.40:1
at maximum gain
at maximum gain (S-Band)
10
8
dB
dB
Group Delay
(per 40 MHz segment)
Linear
Parabolic
Ripple
0.01
0.003
1.0
ns/MHz
ns/MHz2
ns p-p
Transmit Band Noise
Output Power Density
TX Band
-75
dBW/4 KHz
Offset frequency from carrier
1 Hz
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
-110
-120
-130
-135
-140
-140
-140
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
-90
-100
-110
-120
-125
-130
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Range
Accuracy
Psat to (Psat - 20)
± 0.5
dB
dBm
Gain
Gain Flatness
Gain Slope
Gain Variation vs. Temperature
Gain Stability
Gain Adjustment
Intermodulation Distortion
(Two-tone, 5 MHz spacing)
AM/PM Conversion
Spurious
Harmonics (SSPA only)
Input/Output VSWR
Noise Figure
Residual AM Noise, typical
Residual Phase Noise, typical
(SSPA only)
True RF Power Detector
o
/dB
dBc
dBc
dBc
1RU N+1 Redundant Power Supply
The combination of a separate, fully redundant power supply is an excellent means of obtaining the
ultimate in system reliability. The power supply is an N+1 redundant configuration, meaning that there
is one more power supply module available than required to operate the SSPA. A failure of one power
supply module will not take the amplifier off the air.
PAGE 4 OF 8
212887 REV G ECO 17995
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
L-Band Operation
Teledyne Paradise Datacom amplifiers are available with an integrated L-Band Block Up
Converter. L-Band units utilize Teledyne Paradise Datacom’s proprietary zBUC technology.
The addition of a zBUC® converter to the SSPA typically increases the gain by 2-4 dB. The
advantages of zBUC technology include:
• zBUC converter can detect and switch to an extenally supplied reference.
• Optional internal high stability (10MHz) reference.
• zBUC converter can lock to an externally supplied reference of 5, 10, 20, 25, or 50 MHz
without modification.
• zBUC converter can accept a wide range of external reference power (-10 to +5 dBm).
Available Frequency Plans
Band
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
C
Standard C-Band
950 - 1525 MHz
4.900 GHz
5.850 - 6.425 GHz
0-4 dB
C
Extended C-Band
950 - 1825 MHz
4.900 GHz
5.850 - 6.725 GHz
0-4 dB
C
Palapa Band
950 - 1250 MHz
5.475 GHz
6.425 - 6.725 GHz
0-4 dB
C
Insat Band
950 - 1250 MHz
5.775 GHz
6.725 - 7.025 GHz
0-4 dB
C
Extended C-Band 2
950 - 1675 MHz
4.800 GHz
5.750 - 6.475 GHz
0-4 dB
C
Low C-Band
840 - 1000 MHz
4.250 GHz
5.090 - 5.250 GHz
0-4 dB
X
Standard X-Band
950 - 1450 MHz
6.950 GHz
7.900 - 8.400 GHz
0-2 dB
Ku
Standard Ku-Band
950 - 1450 MHz
13.050 GHz
14.00 - 14.50 GHz
0-2 dB
Ku
Extended Ku-Band
950 - 1700 MHz
12.800 GHz
13.75 - 14.50 GHz
0-2 dB
Electrical Specifications for 4RU RM GaN SSPA with zBUC® converter
PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Adjusted Range
Gain Stability
Phase Noise
Spurious
Noise Figure
Input VSWR
Internal Reference Option
PAGE 5 OF 8
NOTES
LIMITS
UNITS
Nominal setting
full band (C-,X-,Ku-bands)
per 40 MHz (C-,X-,Ku-bands)
75
± 2.0
± 0.5
20
60 - 80
57 - 77
± 1.5
dB
dB
dB/40 MHz
dB
dB
dB
dB
Typical C-Band Adj. Range
Typical Ku-Band Adj. Range
0 to +50 °C
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Absolute max.
-30
-60
-70
-80
-90
-90
C-band (typ.)
-60
-80
-80
-85
-120
-125
X-band (typ.)
-60
-75
-75
-100
-110
-122
Ku-band (typ.)
-50
-65
-72
-90
-110
-120
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
In-Band Signal Related (C-/Ku-Band)
(Extended C-Band)
Close to Carrier Spurious (≤ 20 MHz)
Local Oscillator
-50
-40
-50
-30
dBc
dBc
dBc
dBm
At 75 dB gain setting
20
dB
L-Band
1.5 : 1
Aging per day (after 30 days)
Aging per year (after 30 days)
Reference Stability over Temperature (-20 to +85 °C)
± 1 • 10-9
± 6 • 10-8
± 3 • 10-8
212887 REV G ECO 17995
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
Mechanical Specifications
NOTES
LIMITS
UNITS
Size (SSPA)
PARAMETER
width X height X depth
19.0 x 8.75 x 30.0
483 x 222 x 762
inches
mm
Size (Power Supply)
width X height X depth
19.0 x 1.75 x 15.97
483 x 45 x 406
inches
mm
With integrated zBUC converter
120 (54.5)
+1.7 (+0.8)
lbs. (kg)
lbs. (kg)
with four (4) power supply modules
29 (13.2)
lbs. (kg)
Paint
Gray; powder coat
Type N
WR430
WR137 Waveguide
WR112 Waveguide
WR75 Waveguide
Type N
Female
CPR430G Flange (PDR-22)
CPR137G Flange (PDR-70)
CPR112G Flange (PDR-84)
Grooved flange (PBR-120)
Female
Weight (SSPA)
Weight (Power Supply)
Finish
Connectors
RF Input
RF Output (S-Band)
RF Output (C-Band)
RF Output (X-Band)
RF Output (Ku-Band)
RF Output Sample
Environmental Specifications
PARAMETER
NOTES
LIMITS
UNITS
Ambient
0 to +50
°C
Non-condensing
95
%
Cooling System
Forced Convection Air Cooling
Front Panel - Intake
Rear Panel - Exhaust
Audible Noise
Measured 1m from unit, at Psat
61
Operating Temperature
Relative Humidity
dBA
Altitude
No temperature de-rating up to 10,000 ft, (3000 m)
De-rate maximum temperature by 2 °C per 1,000 ft (300 m) beyond 10,000 ft.
Shock
50 g p-p, 11 msec pulses
Vibration
3g rms 30 min. 5-2000 Hz
Receive Band Filter Options
S-Band
A
1.75
0.81
B
1.38
0.69
2.020-2.120 GHz (Band A) : Filter L205250-S3-TX Dimensions: A=9.972 , B=8.500
2.200-2.300 GHz (Band B) : Filter L205250-S4-TX Dimensions: A=12.222 , B=10.750
1.750-2.120 GHz (Band G) : Filter L205250-S11-TX Dimensions: A=4.730 , B=3.250
X-Band
0.79
2.42
8.26
1.96
0.98
1.28
PAGE 6 OF 8
9.83
212887 REV G ECO 17995
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
Redundant and Phase Combined Systems
Teledyne Paradise Datacom’s 5RU Rack Mount SSPAs can be configured in a variety of
redundant and phase combined configurations.
•
•
•
•
•
•
1:1 Redundant System with Internal Redundancy Control
1:1 Redundant System with RCP2-1100 Redundant System Controller
1:1 Fixed Phase Combined System with FPRC-1100 Phase Combined System Controller
1:2 Redundant System with Internal Redundancy Control
1:2 Redundant System with RCP2-1200 Redundant System Controller
1:2 Fixed Phase Combined System with FPRC-1200 Phase Combined System Controller
System Output Power Capacity
Due to residual losses inherent in redundant system configurations (waveguide bends; switch
and coupler losses), reduce the typical output power specification of a single amplifier by
approximately 0.2 dB for 1:1 and by 0.4 dB for 1:2 systems.
In phase combined systems, these same losses result in slightly less than the ideal addition
of 3 dB to the output power of a single HPA unit. For 1:1 phase combined systems, the typical
additive output power is approximately 2.70 dB above the output power of a single HPA. For
1:2 phase combined systems, the typical additive output power is approximately 2.50 dB
above the output power of a single HPA.
Actual system losses will vary based on the system options.
System Controllers
The RCP2/FPRC-1100/1200 system controller provides an extremely user friendly interface
for complete monitor and control of the amplifier system.
RCP2-1100 Redundant System Controller
The front panel mimic display shows the on-line amplifiers and the switch positions. Fault
lights are provided for easy identification of system status. All system monitor and control is
available locally at the front panel LCD display, as well as remotely by the RS232, RS485, or
Ethernet interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the controller.
PAGE 7 OF 8
212887 REV G ECO 17995
Indoor Rack Mount
GaN Solid State Power Amplifiers
5RU Rack Height
Part Number Configuration Matrix
Power Level (Watts)
500, 600, 800,
S-Band 1000 (10K), 1200 (12K),
1600 (16K), 2000 (20K)
300, 400, 650, 800,
C-Band
1300 (13K), 1600 (16K)
300, 400, 650, 800,
X-Band
1300 (13K), 1600 (16K)
300, 400, 500, 600, 800,
Ku-Band
1000 (10K)
Band
S-Band
C-Band
X-Band
Ku-Band
S
C
X
K
A1
B1
C
D1
H
L
1
Block Up Converter
M Internal Reference BUC
P External Reference BUC
X No BUC
Rack Height
5RU
5
P
L
Frequency Sub Band
S-Band
X-Band
1
2.02 to 2.12 GHz
A 7.90 to 8.40 GHz
2.20 to 2.30 GHZ
D 7.70 to 8.40 GHz
1.75 to 2.12 GHz
F 7.10 to 7.40 GHz
C-Band
Ku-Band
5.850 to 6.425 GHz
A1 14.00 to 14.50 GHz
5.850 to 6.725 GHz
B1 13.75 to 14.50 GHz
5.750 to 6.670 GHz
F1 12.75 to 13.25 GHz
6.425 to 7.025 GHz
G1 14.75 to 15.25 GHz
5.715 to 5.790 GHz
4.400 to 5.000 GHz
GaN Device Designator
G GaN Device
Configuration Modifier 2
X Standard
1
Standalone Unit or System Configuration
Standalone amplifier
1:1 System, Input Switching, Internal Control
1:1 System, Input Splitter, Internal Control
1:2 System, Input Switching, RCP2-12002
1:2 System, Input Switching, Internal Control
1:2 Phase Combined System, Input Splitter, FPRC-12002
1:1 System, Input Splitter, RCP2-11002
G 1:1 Phase Combined system, Input Splitter, FPRC-1100
Rx Band Reject Filter
V
Reflected Power Monitor
S-Band and X-Band units only
Example - A standalone 800W GaN C-Band
5RU Rack Mount GaN SSPA with standard
N+1 external power supply and an optional
internal reference block up converter is part
number: HPAC5800ARMXXXPG.
Use and Disclosure of Data
2
H1 1:1 System, Input Switching, RCP2-11002
J 1:2 Phase Combined system, Input splitter, Internal Control
1 Switched input with external reference BUC requires reference distribution box.
2 Standard location for controller is directly above HPA1.
PAGE 8 OF 8
R1
Configuration Modifier 1
X Standard
S Input Sample Port
Available with optional BUC
X
A1
B
C1
D1
E
F
Configuration Modifier 3
Standard (N+1 Power Supply)
N+1 P.S. + Rear Exhaust Adapters
HPA C 5 8 0 0 A R M X X X P G
MODEL:
A
B
G
R
S
T
Y
Z
Standalone Unit or System Package
Standalone amplifier
System with Cabinet, Top Mounted Waveguide Switching
System without Cabinet, Top Mounted Waveguide Switching
System with Cabinet, Rear Mounted Waveguide Switching
System without Cabinet, Rear Mounted Waveguide Switching
The information contained herein is classified as EAR99
under the U.S. Export Administration Regulations.
Export, re-export or diversion contrary to U.S. law is
prohibited.
Specifications are subject to change without notice.