3140 Mounted Planters: Hydraulic Requirements Planter Configuration Requirements Description

3140 Mounted Planters: Hydraulic Requirements Planter Configuration Requirements Description
®
3140 Mounted Planters: Hydraulic Requirements
Planter Configuration
Requirements
3140 Base Machine - Conventional/Mechanical Meters
and Optional Row Marker Package
2 SCV
3140 Base Machine - Conventional/Mechanical Meters,
Optional Row Marker Package, and Dual Lift Assit
3 SCV*
Description
20 gpm
#1 SCV: Planter fold
#2 SCV: Row markers with sequencing/flow control valve
20 gpm
#1 SCV: Planter fold
#2 SCV: Row markers with sequencing/flow control valve
#3 SCV: Dual lift assist
3140 Base Machine - Conventional/Mechanical Meters,
Optional Row Marker Package, Dual Lift Assist and Wing Down Flex
Package
4 SCV*
3140 Base Machine - Conventional/Vacuum Meters
»External case drain required for vacuum hydraulic circuit
2 SCV
3140 Base Machine - Conventional/Vacuum Meters
and Optional Row Marker Package
»External case drain required for vacuum hydraulic circuit
3 SCV
3140 Base Machine - Conventional/Vacuum Meters,
Optional Row Marker Package, and Dual Lift Assist
»External case drain required for vacuum hydraulic circuit
4 SCV*
3140 Base Machine - Conventional/Vacuum Meters,
Optional Row Marker Package, Dual Lift Assist and Wing Down Flex
Package
»External case drain required for vacuum hydraulic circuit
5 SCV*
20 gpm
#1 SCV: Planter fold
#2 SCV: Row markers with sequencing/flow control valve
#3 SCV: Dual lift assist
#4 SCV: Wing down flex
25 gpm
#1 SCV: Vacuum meters
#2 SCV: Planter fold
35 gpm
#1 SCV: Vacuum meters
#2 SCV: Planter fold
#3 SCV: Row markers with sequencing /flow control valve
35 gpm
#1 SCV: Vacuum meters
#2 SCV: Planter fold
#3 SCV: Row markers with sequencing /flow control valve
#4 SCV: dual lift assist package
35 gpm
#1 SCV: Vacuum meters
#2 SCV: Planter fold
#3 SCV: Row markers with sequencing /flow control valve
#4 SCV: dual lift assist package
#5 SVC: wing down flex package
* Some options may be combined to reduce the number of SCV outlets required. Refer to your operator’s manual for additional detail.