460ESPS EtherNet/IP to Profinet IO FEATURES

460ESPS Contact Us: 1-800-249-1612 EtherNet/IP to Profinet IO FEATURES Connect an EtherNet/IP Scanner to a Profinet IO Controller Support for Up to 10 The 460ESPS moves data between an EtherNet/IP Scanner and a Profinet IO Controller. It’s the perfect tool to bridge the gap Siemen controllers and AllenBradley PLC’s. EtherNet/IP Listening Scanners; 1 Scanner Capable of Reading and Writing I/O Map Data from up to 10 Profinet IO Slots in Each Direction Supports 480 Bytes of Data in Each Direction Map EtherNet/IP Data Directly to Profinet Slots Effortless Browser Based Configuration, no programming software is required Simple data translation allows you to manipulate data as it passes between protocols How Do You Map the Data? EtherNet/IP IO data will be mapped into 10 Profinet IO slots. Each Slot will be assigned a typed of Int8, int16, int32, int64, Uint8, Uint16, Uint32, Uint64, float, double, binary8, binary16, binary32 or Short String. The Slot can consist of up to 480 bytes of data from your Ethernet/IP Scanner device. When writing from your Profinet IO Controller to your EtherNet/IP Scanner there will be up to 10 Slots each defined by the same types. Data in those slots can be mapped to your EtherNet/IP device. It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease. Why Use Real Time Automation as a Gateway Supplier? The 460ESPS provides an option to connect an EtherNet/IP Scanner to a Profinet IO Controller. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA. When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else's solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn't require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us. Try the RTA difference today and give us a call at 1-800-249-1612 or check out more information on us and our other solutions at www.rtaautomation.com. A Word from our Founder “It’s likely that your business isn’t industrial networking and it shouldn’t be. You make products, design systems, or manage some process. Whatever it is that you make, monitor or install the process inevitably creates data. If you’re a control engineer and your plant has been around for a few years your line is probably littered with devices that send out all kinds of data over many different protocols. If you’re an automation device developer you probably have customers that need to move your data into some other network. Either way, you’ve got a device conversion problem. You have devices that generate ASCII , Modbus RTU, Modbus TCP, BACnet, Profinet, Profibus, Ethernet TCP/IP , Ethernet/IP, DeviceNet or some other completely proprietary data and now you’re the person that has to move that data to some other network! I feel your pain… and rather than just my sympathy, I have a solution for you. You see, while your business may not be moving data around a factory floor mine is. In fact, it’s all that we have done for over twenty years now. Our 460 series of Device Converters is the culmination of those twenty years. You can now move all of your data, where you want, when you want and how you want. Try us on your next project, I guarantee you wont regret it. John Rinaldi 460ESPS www.rtaautomation.com ETHERNET/IP ADAPTER FEATURES Operation Modes Class 1 I/O Adapter Message Support Implicit Class 1 Cyclic I/O, Explicit Class 3 and UCMM Supported Data Types BIT8,16 & 32; INT8, 16, 32 & 64; UINT8,16, 32 & 64; Float & Double Maximum EtherNet/IP Scanner Devices Up to 10 can listen, only 1 can write I/O Maximum Data Supported Up to 480 bytes in each direction Profinet IO SERVER FEATURES Maximum Number of Slots 10 Slots in, 10 Slots out Slot Size 8, 16, 32, 64 or 128 Bytes Each Slot Can be Defined for a Single Data Type of Int8, int16, int32, int64, UInt8, Uint16, Uint32, Uint64, float, double, binary8, binary16 or binary32, Short String Total Data Supported in Each Direction 1280 Bytes Maximum Profinet IO Controller Connections 1 INCLUDED WITH GATEWAY 120 volt AC wall wart power supply Manual 6’ power cable with flying leads 5 year hardware warranty IPSetup software — automatically locates RTA gateway on the network Unlimited firmware feature upgrades for life CAT5 crossover cable for direct connection to PC during programming Complete, unlimited access to our industry leading support staff ELECTRICAL/ENVIRONMENTAL DC Input Voltage 8 VDC @ 230 mA to 28 VDC @ 80 mA Maximum Baud Rate 115K baud Operating Temperature -40 C to 85 C Certification RoHS-Compliant, UL, CUL, CE Approvals, Class I Div 2 DIMENSIONS ENCLOSURE / HARDWARE Size 4.2” x 3.25” x 1” Weight 5 oz. Enclosure Type Anodized aluminum Mounting Din rail or panel mount LEDs Ethernet link/data LED, Ethernet speed LED, power LED, & 2 general purpose LEDS on side GATWAY FEATURES & FUNCTIONS Gateway Security You can configure up to 9 different users access to diagnostic and configuration screens. Alarming Set <, <=, >=, >, ==, !=, and change-of-state rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent. Translation Table Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway. Status and Counters Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device. Diagnostic Logging Page Allows users to see and log start up sequences, protocol specific messages & error messages. NOT EXACTLY WHAT YOU WERE LOOKING FOR? Real Time Automation offers a full line of gateway products. If this isn’t the one you were looking Give us a call at 1-800-249-1612 or check out a listing at www.rtaautomation.com/products. We also offer custom gateways to help customers dealing with unique needs or proprietary protocols. CATALOG # DESCRIPTION 460ESPS EtherNet/IP Scanner to Profinet IO Gateway For More Information: 1-800-249-1612 [email protected] . www.rtaautomation.com 2014 Copyright Real Time Automation. All rights reserved. The Real Time Automation logo is a registered trademark of Real Time Automation Inc.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement