Vulcan-Hart Stationary Gas Heated Kettle- 60 Gallon. Fully welded hemispherical bottom kettle.
304 Stainless steel jacket and liner. Inside dimensions: 30 in. dia. x 25 in. H. Electric starter: 120 V, 60
Hz, 3 amps, single phase. Inlets: (1) 30 in. dia. open top. Outlets: (1) 3/4 in. dia. NPT (female, gas), (1)
3/4 in. dia. NPT (female, pressure relief), (1) 1 in. dia. NPT (female, kettle), (1) 7 in. dia. exhaust duct.
Overall dimensions: 50 in. L x 43 in. W x 48 in. H.
Item # __________________________
C.S.I. Section 11420
VGL SERIES
GAS STATIONARY 2/3 JACKETED KETTLE
■ VGL20
100,000 BTU/hr., 20 gallon capacity.
■ VGL40
100,000 BTU/hr., 40 gallon capacity.
■ VGL60
130,000 BTU/hr., 60 gallon capacity.
STANDARD FEATURES
OPTIONS
Self generating gas fired power burner, all welded type
304 stainless steel, 2/3 jacketed steam kettle, Vulcan-Hart
Model No. (VGL20) (VGL40) (VGL60). Hinged cover
(60 gallon spring assist). Fully welded hemispheric bottom
kettle with type 304 stainless steel jacket and liner. (Type 316
stainless steel liner 20 & 40 gallons only). Jacket tested to
50 psi (3.4 kg/cm2). Factory charged with chemically pure
water, rust inhibitor, and antifreeze for protection against
freezing to -30°F. Kettle exterior is fully insulated. 2" draw-off
valve with perforated strainer. Recessed control panel located
on front of kettle. Controls include direct immersion thermostat, water sight glass, cooking light and pressure gauge.
Safety features include low water cut-off, pressure relief valve,
pressure switch and gas shut-off valve. Kettles mounted on
stainless steel legs. Requires a 120 volt, 60 Hz, 1 phase power
supply, 3.0 amp. 6' cord and plug supplied. 3/4" rear gas
connection with gas pressure regulator.
■
■
■
■
CSA design certified. NSF listed. Meets ASME code.
SPECIFY TYPE OF GAS WHEN ORDERING.
SPECIFY ALTITUDE WHEN ABOVE 2,000 FT.
Spring assist cover (20 & 40 gallons).
Spring assist cover with condensate ring.
Two piece hinged cover.
Correction facility package.
a. Controls protected by lockable cover (lock by others).
b. Security type tamper resistant fasteners with tack welds.
c. Perforated flue cover.
d. Stainless steel cover over draw-off with chain.
■ 3" draw-off valve with perforated strainer.
■ Type 316 stainless steel liner, 60 gallons.
■ Second year extended limited parts and labor warranty.
ACCESSORIES
■
■
■
■
■
■
■
■
■
■
F-32050 (10-03)
Contour measuring strip.
(12") (18" double jointed) single pantry faucet.
(12") (18" double jointed) double pantry faucet.
Double pantry washdown hose with 16" add-on faucet with
backflow preventer.
Double pantry washdown hose with backflow preventer.
Double pantry pot filler and backflow preventer.
Triple perforated stainless steel basket assembly.
Draw-off valve strainer, solid.
Clean-up kit; includes draw-off brush, clean-up brush w/36"
handle and paddle scraper w/40" handle with nylon blade.
Stainless steel 48" wire whip.
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
MODELS: VGL SERIES Gas Stationary 2/3 Jacketed Kettle
SPECIFICATIONS:
A2780
ISO9001
Vulcan-Hart Co.
■ Self generating gas fired power burner, all welded type 304
stainless steel, 2/3 jacketed steam kettle.
■ Hinged cover (60 gallon spring assist).
■ Fully welded hemispheric bottom kettle with type 304 stainless steel jacket and liner. (Type 316 stainless steel liner 20
& 40 gallons only). Jacket tested to 50 psi (3.4 kg/cm2).
■ Factory charged with chemically pure water, rust inhibitor,
and anti-freeze for protection against freezing to -30°F.
■ Kettle exterior is fully insulated.
■ 2" draw-off valve with perforated strainer.
■ Recessed control panel located on front of kettle. Controls
include direct immersion thermostat, water sight glass,
cooking light, pressure gauge and electronic ignition with
ignitions indicator light.
■ Safety features include low water cut-off, pressure relief
valve, pressure switch and gas shut-off valve.
■ Kettle mounted on stainless steel legs.
■ Requires a 120 volt, 60 Hz, 1 phase power supply, 3.0 amp.
6' cord and plug supplied.
■ 3/4" rear gas connection with gas pressure regulator.
■ One year limited parts and labor warranty.
VGL SERIES
GAS STATIONARY 2/3 JACKETED KETTLE
IMPORTANT:
1. A pressure regulator sized for this unit is included. Minimum supply
pressure: Natural gas 7" W.C. Propane 11" W.C.
2. Gas line connecting to unit must be 3/4" or larger. If flexible connectors
are used, the inside diameter must be at least the same as the 3/4" iron
pipe and rated for the correct gas input.
3. Requires 120 volt, 60 Hz, 1 phase electrical connection. Furnished
with 6' cord and 3 prong plug. 3 amp total draw.
4. An adequate ventilation system is required for commercial cooking
equipment. Information may be obtained by writing to the National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269. When
writing, refer to NFPA No. 96.
MODEL
NO.
BTU/HR.
INPUT
VGL20
100,000
VGL40
100,000
VGL60
130,000
BRIMFUL
4 OZ.
CAPACITY* SVGS.
20 gal., 80 qts.
640
76 liters
40 gal., 160 qts.
1280
152 liters
60 gal., 240 qts.
1920
227 liters
A
20
508
26
660
30
762
B
271/2
698
321/2
825
361/2
927
5. These units are manufactured for installation in accordance with
ANSZ223.1a (latest edition), National Fuel Gas Code. Copies may be
obtained from the American Gas Association. 1515 Wilson Blvd.,
Arlington, VA 22209.
6. Equipment clearance:
Combustible
Non-Combustible
Rear
2"
2"
Right
6"
6"
Left
6"
6"
7. This appliance is manufactured for commercial installation only and is
not intended for home use.
C
40
1016
44
1118
491/2
1257
D
32
813
381/2
978
42
1016
E
3
76
2
51
21/2
63
F
19
483
19
483
211/2
546
G
64
1626
72
1829
85
2159
H
24
610
29
737
35
889
J
301/2
775
35
889
39
991
K
6
152
6
152
8
203
* Working capacity 70% to 80% of brimful depending on model.
GS: See #1 & #2 above,
EC: See #3 above.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-32050 (10-03)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement