Mitsubishi | MSZ-A09NA-1 | Residential and Select Commercial Comfort Systems

Residential and Select Commercial
Comfort Systems
www.mitsubishicomfort.com
“Comfort” is a concept many of us notice most when we’re
uncomfortable. And comfort is our #1 priority at Mitsubishi
Cooling and Heating Solutions.
Our innovative split zoned cooling and
heating systems are designed to improve
the quality of life for you and your family
with personalized comfort control. Their
cutting edge, environmentally sensitive
02
technologies also make them some of the most efficient
HVAC systems in the world.
Perhaps your home has a room that’s always too hot or
too cold. Or, perhaps you’re looking for a way
to precisely control the climate in several rooms
in your home, or in a new addition. No matter
what your cooling and heating needs may be,
Mitsubishi systems are the perfect way to
transform your home into a comfortable oasis.
Mitsubishi Electric Cooling and Heating Solutions
Split zoning technology is a primary source of year-round comfort control world wide. Mitsubishi has been available
in the U.S. for almost 30 years, but is increasing in popularity because it provides comfort and is efficient.
Mitsubishi Electric’s split zoning systems use refrigerant
lines to connect an outdoor unit to one or multiple indoor
air handlers, increasing the energy efficiency within a home.
Advanced technologies are used to help you precisely control
the temperature of each room that has an indoor unit and allows
you to condition only the rooms in use.
Using a wireless remote or wall-mounted controller for each
space, your Mitsubishi Electric system allows a truly personal
level of comfort control. Environmentally friendly refrigerants,
advanced filtration systems and high SEER ratings come
standard on the full product line.
Residential and Light Commercial Applications
System Overview and Technology........................ 04 - 07
SINGLE-ROOM
System Showcase................................................. 08 - 09
MS/MSY WALL-MOUNTED:
Air Conditioners..................................................... 10 - 11
MULTI-ROOM
This synergy of application,
technique and advanced
technology delivers true
eco-comfort for your
home or work space.
M-SERIES: 9,000-36,000 Btu/h
Overview of Multi-Room Systems........................ 14 - 15
MSZ WALL-MOUNTED:
Air Conditioners and Heat Pumps........................ 12 - 13
MSZ-A WALL-MOUNTED and SEZ DUCTED INDOOR
UNITS WITH MXZ MULTI-ROOM SYSTEMS
Air Conditioners and Heat Pumps....................... 16 - 17
MXZ-2B20NA MULTI-ROOM Systems.............. 18 - 19
How environmentally friendly
are Mitsubishi Electric systems?
9
SEZ Indoor Unit Performance Curves......................... 20
MXZ Multi-Room System Combination Options. 21 - 23
systems ENERGY STAR® rated
8 systems qualify for the Federal
Tax Credit offered through the American
Reinvestment and Recovery Act. The tax credit is for
30 percent of total system and installation costs, up to
$1,500, and can be used for a qualified cooling-only,
heat pump or 2-to-1 multi-room heat pump system.
For details on qualifying for the Tax Credit, visit
www.mitsubishicomfort.com/taxcredit or ask
your contractor.
For information on available local rebate opportunities
from state or utility companies, visit www.dsireusa.org.
Cooling-only
Heat Pump
Multi-room
Heat Pump
Energy Star
Tax Credit
MSY/MUY-GE09NA
MSY/MUY-GE12NA
MSY/MUY-GE15NA
MSZ/MUZ-GE09NA
MSZ/MUZ-GE12NA
MSZ/MUZ-GE15NA
MSZ/MUZ-FE09NA
MSZ/MUZ-FE12NA
MXZ-2B20NA
MSY/MUY-GE09NA
MSY/MUY-GE15NA
(with 2-MSZ-GE09)
MSZ/MUZ-GE09NA
MSZ/MUZ-GE12NA
MSZ/MUZ-GE15NA
MSZ/MUZ-FE09NA
MSZ/MUZ-FE12NA
MXZ-2B20NA
(with 2-MSZ-GE09)
Bedrooms, living rooms, dining rooms, basements, sunrooms, new additions
and renovations are applications that can take full advantage of the single and
multi-room Mitsubishi systems.
03
Mitsubishi System Technologies:
a user-friendly zoned residential and light commercial
personalized comfort solution (M-Series wall-mounted and ducted systems)
Comfort is a home that’s cool and dry in the summer and cozy and warm
in the winter. This environment is what you get with the Mitsubishi Electric
system: perfect year-round comfort.
Mitsubishi Electric indoor units are easy to install practically anywhere:
– High on the wall, to blend into a room without taking up window space
– In the ceiling or below the floor and totally out of sight (on ducted systems)
Heat pump systems feature auto mode cooling/heating changeover, which
automatically switches the system between cooling and heating to compensate
for fluctuating temperatures. They’re nearly silent – their fans deliver air quietly
and continuously with only a gentle whoosh for constant circulation and filtration.
For this reason, Mitsubishi ductless systems have long been the choice of
thousands of homes, churches, schools and libraries across the U.S.
Our systems are the perfect way to cool or heat any single room or multiple
rooms in your home or office to attain personal comfort.
Technology Benefits of Mitsubishi Systems
Features
Benefits
INVERTER TECHNOLOGY
IN THE COMPRESSOR
Maximizes energy savings by making sure only the energy needed
to cool or heat an area is used.
EASY INSTALLATION FOR
YOUR CONTRACTOR
Installs quickly and easily, having no need for major construction
and remodeling.
COMPLETE ZONE
CONTROL
ealizes maximum control and energy efficiency by cooling
R
and heating only those spaces in use.
ADVANCED
MICROPROCESSOR
TECHNOLOGY
Creates a comfortable environment no matter what conditions are
outside with our advanced self-monitoring controls.
PERSONAL COMFORT
CONTROL
Convenient comfort control of temperature, fan speed and air
direction in the specific zone with our remote or wired controller.
WASHABLE LONG-LIFE
ANTI-ALLERGEN FILTERS
Improves air quality and saves money by being washable
rather than having to replace the filter.
AUTO COOL/HEAT
CHANGEOVER
Heat pump switches automatically from cooling to heating
(MUZ Systems).
ENVIRONMENTALLY
FRIENDLY REFRIGERANT
Uses R410A, an environmentally friendly refrigerant and a
high percentage is recycleable.
Cutting-edge Technology
Innovative Compressor Technology
In every aspect of a Mitsubishi Electric
system, advanced technology is used
to increase energy efficiency and ecofriendliness while providing innovative
comfort control.
INVERTER-driven compressor systems in
the outdoor unit detect subtle changes in
temperature and, like a car’s cruise control,
automatically adjust compressor speed – unlike
conventional units, which start and stop
repetitively. Special components within
the compressor increase the magnetic
flux and reduce its weight, allowing the
compressor to generate higher energy
efficiencies with better performance than
ever before – at low levels of sound
during start-up and running.
Our technology includes:
• INVERTER-driven compressors
• tremendous heating performance in
Hyper-Heating INVERTER (H2i®) systems
• expanded filter systems
• i-see™ sensor accessory (select models)
04
INVERTER
COMFORT CONTROL ENERGY EFFICIENT
ZONING
EASY INSTALLATION
Heat, and Lots of It
With the advanced technology added
to the already innovative INVERTER
compressor the MSZ-FE high-efficiency
systems are not only ENERGY
STAR® rated and Tax Credit qualified,
providing up 26 SEER, they can provide
exceptional heating performance.
These systems provide heating to -13˚ F and produce up to
100% heating capacity at 5˚ F (MSZ-FE09; 92% capacity at
5˚ F for MSZ-FE12). That is year-round comfort in extreme
climates while being extremely energy-efficient.
Energy Efficiency Recognized
Mitsubishi Electric ductless cooling-only and heat
pump systems are so energy efficient that nine
systems – 45 percent of our residential INVERTERdriven systems – are ENERGY STAR rated.
i-see™ Sensor
Extra Energy Savings
Eight (8) Mitsubishi Electric residential
M-Series systems qualify for the
Economic Stimulus Tax Credit. By
investing in your home’s energy
efficiency, you could qualify for up to
$1,500 in federal tax credits.
(MSZ-FE09/12NA models only)
The i-see sensor detects temperature variations in hard-tocontrol ceiling and floor areas while controlling the airflow
up to a wide 150˚ lateral angle for ultimate comfort (90˚
angle in cooling mode).
By scanning the room and making adjustments based on
ambient temperature readings, MSZ-FE systems achieve
superior cooling/heating performance with extremely
efficient operation.
For details on how to qualify, visit
www.mitsubishicomfort.com/taxcredit
or ask your contractor.
For information on available local
rebate opportunities from state or utility
companies, visit www.dsireusa.org.
05
Superior Operation
Advanced Control Technology
Through Mitsubishi’s advanced controls technology
the indoor unit is powered by the outdoor unit. Three
polarity sensitive wires plus a ground conductor run
from the outdoor to the indoor unit, providing both
power and communication. An advanced wireless
remote control is standard on all ductless models.
An optional wired on-the-wall controller is
available for wall-mounted indoor units on
INVERTER systems (also requires MAC-397
adapter) while standard on ducted units.
Quiet Operation
System Control in the Palm of Your Hand
Do you hear that? No? You barely hear our systems
because Mitsubishi indoor units operate with barely a
whisper. For example:
Mitsubishi Electric offers a comprehensive remote controller
that controls temperature, fan speed and more. Choose from
four modes: COOL, HEAT, AUTO and DRY. The controller
also has a 12-hour ON/OFF timer for one-button control of
your personal comfort.
Police siren Circular saw Vacuum cleaner Library reading room
Whisper-tone voice Our Indoor Units
(at low speed)
118 decibels
107 decibels
74 decibels
33 decibels
35 decibels
19 - 34 decibels
Did you hear that? We hope you did.
Warm Air, No Drafts
Our hot-start heat pump technology provides warmth
from the beginning. The fan increases in speed as
the coil is warmed, reducing drafts so when you want
warm air, you’ll get it.
WHISPER QUIET
COMFORT
06
Auto Changeover on Heat Pump
Systems (MUZ outdoor units)
Our heat pump systems sense whether a space needs
cooling or heating and automatically switch modes as
needed to maintain a consistent temperature within the
selected range of a single zone.
Easy to Maintain
With easily accessible filters, little or no ductwork to
clean, and uncomplicated wiring connection points
between the indoor and outdoor units, Mitsubishi
systems rely on minimal maintenance, providing
another level of comfort.
HEALTHIER AIR
SET IT AND FORGET IT
Total Comfort
Programmable Comfort
Smart Set featured on MSZ-GE systems
provides the option to program multiple
settings into one ‘quick’ press feature
providing an additional level of
comfort control.
Additional Air Circulation
With the WIDE VANE or SWING mode, available on the MSY(Z)-GA24/
D30/36NA, there is an option for seven horizontal airflow directions that
provide 150˚ of airflow for greater conditioned air circulation.
The POWERFUL mode (found on select
systems) is available to cool or heat any
desired space quickly by lowering the set
temperature in cooling mode or raising
the set temperature in heating mode,
both by 7˚ F. In Powerful Mode, the fan
speed increases for 15 minutes then
resumes standard operation.
150˚
STANDARD FILTER SYSTEM
Multiple Filters for Cleaner,
Healthier Air
Mitsubishi indoor units use a sophisticated
multi-part filter system to remove
contaminants such as allergens, viruses
and bacteria from the air as it circulates.
The hybrid catechin pre-filter absorbs odorcausing gases. A Blue-Enzyme anti-allergen
filter reduces germs, bacteria and viruses
and helps trap dust, pollens, mites and other
particles; the filter uses an enzyme catalyst
to help break down the sulfur atom bonds
in allergen proteins, transforming them into
non-allergen proteins.
(USED IN MSY/MSZ-GE/GA/D MODELS)
Front Panel
Hybrid Catechin
pre-filters
Blue Enzyme
Anti-allergen filter
A hybrid-coating process makes the
catechin filter washable and, if properly
maintained with monthly cleanings, effective
for more than 10 years.
The high-efficiency MSZ-FE09/12NA indoor
units incorporate the standard Catechin
filter plus two more filters for triple filtration.
The second filter, a Blue-Enzyme filter made
of a fibrous material, also render allergens
harmless using enzymes. The third filter, a
Platinum Catalyst Deodorizing filter, has a
ceramic surface absorption element and
uses nanotechnology for high power odor
absorption. This combination of filter types
provides a complete air purifying system
along with the ultimate comfort solution.
ENHANCED FILTER SYSTEM
(USED IN MSZ-FE09/12NA MODELS)
Front Panel
Hybrid Catechin
pre-filters
Platinum Catalyst
Deodorizing filter
Blue Enzyme
Anti-allergen filter
07
Product Line-Up Showcase
SYSTEM MODELS AND CONTROLLERS
SINGLE-ROOM, WALL-MOUNTED A/C
MS/MU
Air Conditioners
9,500 to 12,000 Btu/h
13 SEER
(cooling only)
MSY/MUY
Air Conditioners
9,000 to 34,600 Btu/h
15.1 - 21 SEER
• Available in cooling only
• Uses a non-INVERTER compressor
• Wireless remote controller
• Ideal for applications such as
- Bedrooms, garages and bonus rooms in warm climates
- Video monitoring room
• Available in cooling only
• INVERTER-driven compressor
• Wireless remote controller
• WIDE Vane buttom for a wider angle of air low, 150˚ from
left to right (on GA24/D30/D36 models)
• Ideal for applications such as
- Bedrooms, garages and bonus rooms in warm climates
SINGLE- R O O M , W A L L - M O U N T E D H E A T P U M P S
MSZ/MUZ
Heat Pumps
9,000 to 33,200 Btu/h
14.5 - 21 SEER
8.2 - 10 HSPF
(cooling and heating)
• INVERTER-driven compressor
• Provides cooling and heating in a wide range of capacities
• Wireless remote controller
• WIDE Vane bottom for a wider angle of air flow, 150˚ from left to right (on GA24/D30/D36 models)
• Ideal for applications such as:
- Bedrooms, home offices, living rooms,
dining rooms, bonus rooms, basements, kitchens, guard houses and more
The following is a quick reference list of the residential
cooling-only, heat pump and multi-room heat pump
systems that are ENERGY STAR® and Tax Credit qualified.
Up to 26 SEER!
Visit www.mitsubishicomfort.com/taxcredit for additional
information on how to apply for the tax credit.
Cooling-only
Heat Pump
Multi-room
Heat Pump
08
Energy Star
Tax Credit
MSY/MUY-GE09NA
MSY/MUY-GE12NA
MSY/MUY-GE15NA
MSZ/MUZ-GE09NA
MSZ/MUZ-GE12NA
MSZ/MUZ-GE15NA
MSZ/MUZ-FE09NA
MSZ/MUZ-FE12NA
MXZ-2B20NA
MSY/MUY-GE09NA
MSY/MUY-GE15NA
(with 2-MSZ-GE09)
MSZ/MUZ-GE09NA
MSZ/MUZ-GE12NA
MSZ/MUZ-GE15NA
MSZ/MUZ-FE09NA
MSZ/MUZ-FE12NA
MXZ-2B20NA
(with 2-MSZ-GE09)
•
•
•
•
•
MSZ/MUZ-FE09/12NA
High-Efficiency Heat Pumps
9,000 and 12,000 Btu/h
23 - 26 SEER
10 - 10.6 HSPF
INVERTER-driven compressor
Quite operation as low as 19dB(A)
i-see™ sensor technology
Enhanced filtration system
H2i® high heat capabilities (see page 12)
- MSZ-FE09 is 100 percent @ 5˚ F
- MSZ-FE12 is 92 percent @ 5˚ F
MULTI-RO O M H E A T P U M P w i t h W A L L - M O U N T E D a n d D U C T E D I N D OOR UNITS
(cooling and heating)
• Connect multiple indoor units (wall-mounted and/or ducted)
• INVERTER-driven compressor
• Provides cooling and heating in a wide range of capacities
• Ideal for applications such as:
- Bedrooms, home offices, living rooms, dining rooms, bonus rooms, basements, kitchens and more
For more information on multi-room
systems refer to pages 14-23.
MXZ Multi-Room
INVERTER Heat Pump
with MSZ Wall-mounted
and/ or SEZ Ducted
Indoor Units
20,000 to 36,000 Btu/h
Ducted Personal Comfort
ALL NEW MXZ-2B20NA IS
CERTIFIED ENERGY STAR AND
FEDERAL TAX CREDIT QUALIFIED!!
(WHEN USED WITH TWO-MSZ-GE09NA INDOOR UNITS)
(SEZ for MXZ systems only)
If you are looking for discrete zoned comfort control, then a ducted unit is
right for you. When connected to a MXZ multi-room system, the SEZ ducted
units provide you with energy efficiency, quiet operation, and a compact
design for quick, easy installation either hidden in the ceiling or beneath the floor.
These models offer the added flexibility of working in tandem with ductless models on the same system,
providing a wide array of installation options to best fit your application needs.
For more information, see our MXZ multi-room section on pages 14 - 23.
WIRELESS and WIRED REMOTE CONTROLLERS
Wireless remote
controller for wallmounted systems
Set Temperature
On/Off
Timer Menu
Fan Speed
Mode
Set Time
Fan Speed
Operation Select
(Heat, Cool, Auto, Dry)
Filter
Test Run
Timer
Check
Airflow Up/Down
Timer On/Off
Vane Control
Econo Cool
Wide Vane
MSY(Z)-A24/D30/
D36NA (only)
Reset
Clock Set
Louver
HR./MIN.
(Time Set)
Ventilation
Powerful: Faster
Cooling or Heating
Wired controller for the
SEZ ducted indoor unit.
(optional controller for
wall-mounted systems and
requires MAC-397 adapter)
Sliding Cover
09
(MS-A12WA MODEL SHOWN)
MS/MSY COOLING-ONLY
NON-INVERTER
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Power Supply
Voltage
MS-A12WA
MU-A12WA
12,000
Rated Capacity
Btu/h
9,500
Capacity Range
Btu/h
-
-
Total Input
W
870
1,070
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Phase, Cycle, Voltage
Indoor - Outdoor L1-N-2
Indoor - Outdoor L1-N-2
Indoor - Remote Controller
MCA
Fan Motor
SEER
Pints/h
Airflow (Lo-Med-Hi)
Indoor Unit
MS-A09WA
MU-A09WA
Sound Pressure Level
(Lo-Med-Hi)
External Finish Color
Dimension Unit
A
F.L.A.
DRY (CFM)
WET (CFM)
dB(A)
13
2.7
3.2
0.68
0.70
1 Phase, 60Hz, 115V *2
AC 115V
AC 115V
Wireless Type
1.2
0.95
183-261-335
222-286-406
162-233-300
198-254-363
26-32-40
W: In.
D: In.
H: In.
11-3/4
Weight Unit
Field Drainpipe Size O.D.
Lbs.
In.
23
5/8
MCA
A
14
MOCP
(Time Delay) A
15
20
Fan Motor
F.L.A.
0.63
0.93
Model (Type)
Compressor
Outdoor Unit
Airflow
Single Rotary
9.3
L.R.A.
47
56
CFM
1,083
1,327
Weight
dB(A)
47
Munsell No. 3Y 7.8/1.1
31-1/2
33-7/16
D: In.
11-1/4
11-7/16
H: In.
21-5/8
23-13/16
Lbs.
78
Type
Refrigerant
Type
Charge
Oil
Lbs., Oz.
Type (Fl. Oz.)
2, 5
Gas Side O.D.
In.
3/8
Connection Method
Height Difference (Max.)
52
W: In.
Remote Controller
Liquid Side O.D.
10.82
Capillary Tube
External Finish Color
Dimensions
16
R.L.A.
Refrigerant Control
Sound Pressure Level
(Cooling) *1
Refrigerant Pipe
33-38-45
Munsell No. 1.0Y 9.2/0.2
30-11/16
8-1/4
96
Wireless Remote
R410A
Ft.
3, 1
NE022 (10.8)
1/2
1/4
35
Length (Max.)
65
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
10
INVERTER
(MSY-GE17NA MODEL SHOWN)
MSY COOLING-ONLY (CONT.)
TAX
C REDIT
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Power Supply
Voltage
9,000
12,000
14,000
17,200
22,000
30,700
34,600
3,800-12,200
3,800-13,600
9,800-30,700
9,800-34,600
W
3,700-18,700
1,640 (2402,070)
4,400-22,000
Total Input
3,100-18,200
1,080 (1602,000)
Energy Efficiency
SEER
19.2
Moisture Removal
Sensible Heat Factor
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Fan Motor
Pints/h
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
External Finish Color
A
F.L.A.
DRY
(CFM)
WET
(CFM)
660 (205-1,200) 960 (205-1,300)
21
20.5
21
1.5
0.82
2.5
0.74
2.7
0.80
Charge
Oil
Connection
Method
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
17.5
109-134-201-286-364
dB(A)
19-22-30-37-43 19-22-30-37-45 26-32-38-44-49 28-33-38-44-49
W: In.
D: In.
H: In.
Lbs.
In.
A
A
F.L.A.
Model
(Type)
R.L.A.
L.R.A.
CFM
31-7/16
9-1/8
11-5/8
22
16
15.1
9.9
0.64
11.9
0.62
389-639-848
350-576-763
34-40-49-51
32-42-49
Munsell No. 1.0Y 9.2 / 0.2
Airflow (Cooling)
Refrigerant Control
Sound Pressure Level at Cooling *1 dB(A)
External Finish Color
W: In.
D: In.
Dimensions
Weight
Remote Controller Type
Type
2,500 (270-2,500) 3,380 (620-3,380) 4,240 (620-4,240)
4.6
7.3
0.71
0.63
1-phase, 60Hz, 208 / 230V *2
AC 208 / 230V
DC12-24V
Wireless Type (Optional Wired Controller: DC 12V)
1.0
0.76
205-272-335230-275-339296-431-568-624
420-533
420-533
170-237-300194-240-304265-385-508-558
385-498
385-498
145-170-237-321-399
Lbs.
Lbs.,
Oz.
Type
(fl. oz.)
In.
In.
Ft.
Ft.
43-5/16
10-1/4
12-13/16
37
46-1/16
11-5/8
14-3/8
40
17
20
21
25
5/8
14
12
15
0.50
0.93
DC INVERTER-driven
DC INVERTER-driven Twin Rotary
6.6
8.2
1,151
7.4
9.3
1,243
1,229
46
49
H: In.
Refrigerant Pipe
Length
MSY-D36NA
MUY-D36NA
Btu/h
Compressor
Refrigerant Pipe
MSY-D30NA
MUY-D30NA
MSY-GA24NA
MUY-GA24NA
Btu/h
Weight Unit
Field Drainpipe Size O.D.
MCA
MOCP
Fan Motor
Refrigerant
MSY-GE18NA
MUY-GE18NA
Capacity Range
Dimension Unit
Outdoor Unit
MSY-GE09NA MSY-GE12NA MSY-GE15NA
MUY-GE09NA MUY-GE12NA MUY-GE15NA
Rated Capacity
Airflow at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
Indoor Unit
TAX
CREDIT
10.0
12.8
12.5
16.0
1,730
1,729
Linear Expansion Valve
54
Munsell No. 3Y 7.8 / 1.1
16
20
1,941
55
56
31-1/2
11-1/4
13
13
13
21-5/8
33-7/16
33-7/16
33-7/16
66
33-1/16
77
1, 12
80
119
117
Wireless Remote (Optional Wired Controller)
R410A
2, 9
3, 7
NEO22 (10.8)
141
4
4, 10
NEO22 (15.2)
3/8
1/4
NE022 (29.5)
1/2
1/4
5/8
3/8
40
65
Indoor/Outdoor
50
100
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
11
INVERTER
(MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP
TAX
CREDIT
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Heating at 47° F *2
Heating at 17° F *3
Power Supply
Voltage
Indoor Unit
MSZ-GE09NA
MUZ-GE09NA
9,000
9,000
12,000
12,000
3,800-12,200
2,800-9,000
3,800-13,600
2,800-12,000
Total Input
W
660 (205-1,200)
580 (160-650)
960 (205-1,300)
930 (160-960)
Energy Efficiency
SEER
21
26
20.5
Moisture Removal
Sensible Heat Factor
Rated Capacity
Capacity Range
Total Input
HSPF (IV)
Rated Capacity
Rated Total Input
Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
Indoor - Outdoor S2 - S3
Indoor - Remote Controller
MCA
Fan Motor
Pints/h
Btu/h
Btu/h
W
Btu/h/W
Btu/h
W
Btu/h
A
F.L.A.
Airflow at Cooling (Lo-Med-Hi-Super DRY (CFM)
HI-Powerful) *1
WET (CFM)
Airflow at Heating (Lo-Med-Hi-Super
WET (CFM)
HI-Powerful) *2
Sound Pressure Level at Cooling (LodB(A)
Med-Hi-Super HI-Powerful) *1
Sound Pressure Level at Heating
dB(A)
(Lo-Med-Hi-Super HI-Powerful) *2
External Finish Color
W: In.
Dimension Unit
D: In.
H: In.
Weight Unit
Lbs.
Field Drainpipe Size O.D.
In.
MCA
A
MOCP
A
Fan Motor
F.L.A.
Airflow (Cooling/Heating)
Refrigerant Control
Defrost Method
Weight
Refrigerant Pipe Length
Connection Method
12
MSZ-FE12NA
MUZ-FE12NA
Btu/h
Dimensions
Refrigerant Pipe
MSZ-GE12NA
MUZ-GE12NA
Btu/h
Sound Pressure Level at Cooling *1
Sound Pressure Level at Heating *2
External Finish Color
Refrigerant
MSZ-FE09NA
MUZ-FE09NA
TAX
CREDIT
Capacity Range
Compressor
Remote Controller
TAX
CREDIT
Rated Capacity
Model (Type)
Outdoor Unit
TAX
CREDIT
1.5
0.82
10,900
4,500-14,100
760 (255-1,200)
6,600
700
8,700
145-170-237-321-399
109-134-201-286-364
162-226-381-410
144-202-350-367
166-240-367-381
145-170-237-321-406
166-240-399-420
19-22-30-37-43
22-31-39-42
19-22-30-37-45
22-33-43-45
19-22-30-37-43
22-31-40-42
19-22-30-37-43
22-33-43-44
9-1/8
22
0.50
DC INVERTER-driven
R.L.A.
L.R.A.
CFM
6.6
8.2
1,151 / 1,225
dB(A)
dB(A)
46
50
W: In.
D: In.
H: In.
Lbs.
66
Munsell No. 1.0Y 9.2 / 0.2
31-7/16
10-1/8
9-1/8
11-5/8
27
22
5/8
12
15
0.56
0.50
DC INVERTER-driven
DC INVERTER-driven
Twin Rotary
8.6
6.6
10.8
8.2
1,102 / 1,187
1,229 / 1,172
Linear Expansion Valve
Reverse Cycle
48
49
49
51
Munsell No. 3Y 7.8 / 1.1
31-1/2
11-1/4
21-5/8
80
77
Wireless Remote (Optional Wired Controller)
R410A
Lbs., Oz.
Type (fl. oz.)
In.
In.
Ft.
Ft.
23
2.9
0.73
13,600
3,000-21,000
950 (150-2,250)
10.6
8,300
800
13,600 (12,500 @ 5˚ F)
145-170-237-321-406
Type
Type
Charge
Oil
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
Indoor/Outdoor
2.5
2.1
0.76
0.74
10,900
14,400
3,000-18,000
5,500-18,100
710 (150-2,250)
1,170 (340-1,660)
10
6,700
8,800
650
900
12,500 (10,900 @ 5˚ F)
11,200
1-phase, 60Hz, 208 / 230V *4
AC 208 / 230V
DC12-24V
Wireless Type (Optional Wired Controller: DC 12V)
1.0
0.76
162-226-339-381
145-170-237-321-399
144-202-307-343
109-134-201-286-364
1, 12
2, 9
NEO22 (10.8)
3/8
1/4
40
65
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
10-1/8
27
0.56
DC INVERTER-driven
Twin Rotary
8.6
10.8
1,102 / 1,187
48
49
80
INVERTER
(MSY(Z)-D30NA MODEL SHOWN)
MSZ HEAT PUMP
(CONT.)
TAX
CREDIT
Model Name
Cooling *1
Heating at 47º F *2
Heating at 17º F *3
Power Supply
Voltage
Indoor Unit
MSZ-GE15NA
MSZ-GE18NA
MSZ-GA24NA
Outdoor Unit
MUZ-GE15NA
MUZ-GE18NA
MUZ-GA24NA
Rated Capacity
Btu/h
14,000
17,200
22,000
Capacity Range
Total Input
Energy Efficiency
Moisture Removal
Sensible Heat Factor
Rated Capacity
Btu/h
W
SEER
Pints/h
3,100-18,200
1,080 (160-2,000)
21
2.7
0.80
18,000
3,700-18,700
1,640 (240-2,070)
19.2
4.6
0.71
21,600
4,400-22,000
2,500 (270-2,500)
17.5
7.3
0.63
23,200
Capacity Range
Btu/h
Total Input
HSPF (Region IV)
Rated Capacity
W
Btu/h/W
Btu/h
Total Input
W
Maximum Capacity
Phase, Cycle, Voltage
Indoor - Outdoor S1-S2
Indoor - Outdoor S2-S3
Indoor - Remote Controller
MCA
Fan Motor
Btu/h
Airflow (Cool) (Lo-Med-Hi-Super HI-Powerful) *1
Btu/h
Indoor Unit
Sound Level Pressure (Heating) (Lo-Med-HiSuper HI-Powerful) *2
3,500-25,200
3,600-24,400
1,900 (230-2,680)
10
13,400
2,140 (250-2,520)
9.5
14,000
1,150
1,450
1,635
15,900
17,200
Refrigerant
Refrigerant Pipe
Connection Method
33,200
8,700-34,000
8,700-36,000
3,360 (520-3,600) 3,840 (520-4,100)
8.2
19,500
21,800
2,400
2,820
WET (CFM)
170-237-300-385-498 194-240-304-385-498 265-385-508-558
205-247-304-367-463
230-275-339-431-512
350-486-568-590
350-576-763
445-639-848
26-32-38-44-49
28-33-38-44-49
34-40-49-51
32-42-49
26-30-35-40-46
28-33-38-43-48
34-40-48-49
34-42-49
dB(A)
Munsell No. 1.0Y 9.2/0.2
43-5/16
W: In.
31-7/16
Dimension Unit
D: In.
9-1/8
10-1/4
11-5/8
Weight Unit
Field Drainpipe Size O.D.
MCA
MOCP
Fan Motor
H: In.
Lbs.
In.
A
A
F.L.A.
Model (Type)
11-5/8
22
12-13/16
37
5/8
17
20
14-3/8
40
Compressor
R.L.A.
7.4
10.0
12.8
L.R.A.
9.3
12.5
16.0
CFM
1,243 / 1,229
1,730 / 1,659
49
54
Airflow
Refrigerant Control
Defrost Method
Sound Pressure Level
External Finish Color
Dimensions
Remote Controller
30,700
9,800-30,700
9,800-33,200
3,850 (620-3,850) 4,360 (620-4,360)
14.5
9.9
11.3
0.64
0.62
32,600
35,200
A
F.L.A.
DRY (CFM)
External Finish Color
Outdoor Unit
MSZ-D36NA
MUZ-D36NA
15,200
20,800
22,800
1 Phase, 60Hz, 208/230V *4
AC 208 / 230V
DC12-24
Wireless Type (Optional Wired Controller: DC12V)
1.0
0.76
205-272-335-420-533 230-275-339-420-533 296-431-568-624
389-639-848
Airflow (Heat) (Lo-Med-Hi-Super HI-Powerful) *2 DRY (CFM)
Sound Pressure Level (Cooling) (Lo-Med-HiSuper HI-Powerful) *1
4,800-20,900
1,600 (270-2,010)
10
11,300
MSZ-D30NA
MUZ-D30NA
Weight
Type
Type
Charge
Oil
Gas Side O.D.
Liquid Side O.D.
Height Difference (Max.)
Length (Max.)
Indoor/Outdoor
dB(A) *1
12
0.50
W: In.
D: In.
H: In.
31-1/2
11-1/4
21-5/8
Lbs.
80
Lbs., Oz.
Type (Fl. Oz.)
2, 9
21
25
0.93
DC INVERTER-driven Twin Rotary
NE022 (15.2)
1/2
In.
Ft.
14
15
46-1/16
16
20
1,729 / 1,660
Linear Expansion Valve
Reverse Cycle
1,941
55
Munsell No. 3Y 7.8/1.1
33-1/16
13
33-7/16
56
119
117
Wireless Remote (Optional Wired Controller)
R410A
3, 7
4
NEO 22(15.2)
141
4, 10
NE022 (29)
5/8
1/4
3/8
40
65
50
100
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
13
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM
With a multi-room system, you can enjoy your ideal level of comfort in the most important rooms in your home.
Each room (zone) operates independently. People in difference rooms – the kitchen, master bedroom or living
room – can enjoy temperature settings that make each of them most comfortable.
If you’re looking for a complete comfort solution for several different rooms, the MXZ multi-room
system is the right choice. The system is flexible enough to conform to your particular cooling and
heating needs, with over 40 different indoor unit combinations, up to four indoor units connected to
one outdoor unit. And now, with a SEZ horizontal ducted unit, you can enjoy an even greater
range of zoning options provided by an MXZ system.
An MXZ multi-room system is an excellent choice for supplementing capacity to
your current system or to condition newly finished spaces or new additions.
You can also benefit from lower energy costs year-round while staying
comfortable, thanks to Mitsubishi’s energy-efficient technologies.
The new dual-zone MXZ-2B20 system with two MSZ-GE09
wall-mounted indoor units also qualifies for both
ENERGY STAR® and the Federal Tax Credit.
At right: a single level home with several
system types represented.
(For illustrative purposes only.)
To find out which system
is the best solution for you,
contact your local
Mitsubishi Diamond
Dealer for an
in-home evaluation.
SEZ Indoor Unit
MXZ Multi-Room Systems
MXZ Outdoor Unit
EXAMPLE OF
OUTDOOR UNIT
EXAMPLES OF
INDOOR UNITS
14
Available in 2-to-1, 3-to-1 and 4-to-1
indoor units to one outdoor unit
systems with wall-mounted and/or
ducted indoor unit styles in a wide
range of capacities, the MXZ multiroom system has the right solution
for your needs.
MSZ Wall-Mounted Indoor Units for
MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities, each
wall-mounted indoor unit mounts high on a wall and connects to
the outdoor unit by a refrigerant line run via a 3” hole. The MSZ
units provide highly efficient solutions to cooling and heating
needs, and provide personalized comfort for the individual
zones in which they are installed.
Features of the MSZ units on MXZ systems include:
• Sleek, flat panel design
• Hot-start technology
• Quiet operation
• i-see™ sensor technology (MSZ-FE only)
• Enhanced filtration system
• Wireless remote control
MSZ Indoor Unit
MUZ Outdoor Unit
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide similar split air-conditioning system advantages, with the added
benefit of being concealed to provide virtually no visual footprint within the conditioned space
other than a register and grille for the air to flow. With the use of short run ductwork, these units
can provide comfort to a single room that needs air dispersed evenly throughout the space,
unusually shaped rooms and even adjacent rooms.
Other features of the SEZ unit on MXZ systems include:
• Concealed design for short run ductwork
• Quiet operation
• Built-in condensate lift mechanism
• Wired remote control
15
INVERTER
MULTI-ROOM MXZ INVERTER HEAT PUMP
Model Name
Outdoor Unit
Cooling *1
Non-ducted/Ducted
Rated Capacity
Capacity Range
Total Input
Rated Capacity
Heating at 47º F *2 Capacity Range
Non-ducted/Ducted
Outdoor Unit
Power Supply
Voltage
W
Btu/h
W
Btu/h
W
MOCP
A
Fan Motor
F.L.A.
Airflow (Cooling/Heating) *1/*2
Refrigerant Control
Defrost Method
Sound Pressure Level
(Cooling/Heating) *1/*2
20,000/20,000
7,800-20,000
2,150 (630-2,150)
22,000/22,000
28,400/27,400
12,600-28,400
3,250 (1,000-3,330)
28,600/27,600
36,000/34,400
12,600-36,400
3,820 (1,000-4,020)
36,000/34,400
8,500-22,000
11,400-36,000
11,400-43,000
Btu/h
Total Input
Rated Capacity
Heating at 17º F *3 Total Input
Non-ducted/Ducted
Maximum Capacity
Maximum Total Input
Phase,Cycle,Voltage
Indoor - Outdoor S1-S2
Indoor - Outdoor S2-S3
MCA
Compressor
Outdoor Unit *4
MXZ-2A20NA *5 MXZ-3A30NA *6 MXZ-4A36NA *7
Btu/h
Btu/h
W
Btu/h
A
1,780 (520-1,780)
2,180 (740-2,880)
3,100 (740-4,350)
14,500/12,500
16,000/15,100
19,400/20,300
1,500/1,430
1,690/1,590
2,330/2,340
14,500/12,500
18,800/18,000
24,600/25,400
1,500/1,430
2,120/2,140
3,340/3,450
1 Phase, 60Hz, 208 / 230V *8
AC 208-230V
DC12-24V
15
19
DC INVERTER-driven Twin Rotary
11
14.4
15
1,485/1,640
1,365/1,605
2,068/2,068
Linear Expansion Valve
Reverse Cycle
49/51
Munsell No. 5Y 8/1
W: In.
D: In.
H: In.
Lbs.
Weight
Type
Type
Refrigerant
Charge
Oil
Gas Side O.D.
Liquid Side O.D.
Refrigerant Pipe
Height Difference (Max.)
Length (Max.)
Length (Each Indoor Unit)
Connection Method Indoor/Outdoor
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C),
W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º
F (24º C).
0.93
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C),
W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C),
W.B. 43º F (6º C).
10.1
dB(A)
Dimensions
NOTES: Test conditions are based on AHRI 210/240. One
indoor unit is turned off during low-speed testing under
the new test conditions. Systems actually exhibit higher
energy efficiencies during normal operation.
20
0.96
Model (Type)
R.L.A.
L.R.A.
CFM
External Finish Color
*Compatible with the MSZ-A, MSZ-FD and SEZ series
indoor units
Remote Controller
Lbs., Oz.
Type (Fl. Oz.)
In.
Ft.
49/49
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C),
W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C),
W.B. 15º F (-9º C).
54/57
*4 Refer to pages 12 and 13 for Indoor Unit specifications.
Munsell No. 3Y 7.8/1.1
33-1/16
35-7/16
13 (+1-3/16)
12-5/8 (+1-3/16)
27-15/16
35-7/16
130
148
150
Associated With Indoor Unit Model
R410A
5,15
7,11
8,13
NEO22 (23.7)
NEO22 (29.4)
A, B: 3/8
A: 1/2; B, C: 3/8
A: 1/2; B, C, D: 3/8
1/4
49/33 *9
164 (A+B)
230 (A+B+C)
230 (A+B+C+D)
82
Flared/Flared
*5 Data from combination of Indoor Units MSZ-A09NA and
MSZ-A12NA.
*6 Data from combination of Indoor Units MSZ-A09NA, MSZA09NA and MSZ-A12NA.
*7 Data from combination of four MSZ-A09NA Indoor Units.
*8 Indoor units receive power from outdoor units through
field-supplied interconnected wiring.
*9 49’ Applies to installations where the outdoor unit is
installed below the indoor unit.
Power factor equals 97 percent.
Specifications are subject to change without notice.
LIMITED WARRANTY | Seven-year warranty
on compressor. Five-year warranty on parts.
Rate d C o m b i n a t i o n s
The charts below indicate the rated capacities for each of the
MXZ systems.
With the addition of ducted indoor units to the MXZ-Series, the number
of available combinations has greatly expanded. The installation specifications and rated capacities vary on systems using wall-mounted only
(MSZ-A and/or MSZ-FD), ducted only or a combination of unit styles.
MXZ-2A20NA Combinations
9+9
9 + 12
9 + 15
12 + 12
MXZ-3A30NA Combinations
9+9
9 + 12
9 + 15
9 + 17 or 18
9 + 24
12 + 12
12 + 15
12 + 17 or 18
15 + 15
15 + 17 or 18
17 or 18 + 17 or 18
9+9+9
16
MXZ-4A36NA Combinations
9+9+9
9 + 9 + 12
9 + 9 + 15
9 + 9 + 17 or 18
9 + 9 + 24
9 + 12 + 12
9 + 2 + 15
9 + 12 + 17 or 18
9 + 15 + 15
9 + 15 + 17 or 18
9 + 17 + 17 or 18
12 + 12 + 12
12 + 12 + 15
12 + 12 + 17 or 18
12 + 15 + 17 or 18
9+9+9+9
9 + 9 + 9 + 12
9 + 9 + 12
9 + 9 + 9 + 15
9 + 9 + 15
9 + 9 + 17 or 18
9 + 9 + 12 + 12
SEER and HSPF Ratings
Model
MXZ-2A20NA
MXZ-3A30NA
MXZ-4A36NA
Indoor Unit Type
SEER
HSPF
Non-ducted
16
8.5
Ducted and Non-ducted
15.5
8.5
Ducted
15.5
8.5
Non-ducted
16
10
Ducted and Non-ducted
15.2
9.7
Ducted
14.5
9.5
Non-ducted
16
8.5
Ducted and Non-ducted
15.5
8.75
Ducted
15
9
MSZ WALL-MOUNTED INDOOR UNITS
(FOR MXZ-2A20/3 A 3 0 / 4 A 3 6 N A O U T D O O R U N I T S )
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Heating at 47º F *2
Power Supply
Rated Capacity
Total Input
Rated Capacity
Total Input
MSZ-A09NA
MSZ-FD09NA
9,000
16
10,900
16
9,000
18
10,900
24
Btu/h
W
Btu/h
W
MSZ-A12NA MSZ-FD12NA MSZ-A15NA
For Use with all MXZ-Series
12,000
21
13,600
21
Phase, Cycle, Voltage
A
F.L.A.
DRY (CFM)
Airflow (Cool)
(Lo-Med-Hi) *1
WET (CFM)
Airflow (Heat) (Lo-Med-Hi) *2 DRY (CFM)
162-226-339
144-202-307
166-240-367
22-33-38
22-31-39
22-34-42
22-33-43
22-33-38
22-31-40
22-34-42
22-33-43
W: In.
30-11/16
31-7/16
30-11/16
D: In.
8-1/4
10-1/8
8-1/4
H: In.
11-3/4
11-5/8
11-3/4
Weight
Lbs.
23
27
23
Field Drainpipe Size
In.
Sound Pressure Level (Cooling) (Lo-Med-Hi) *1
External Finish Color
34-40-45
296-431-568
265-385-508
296-486-568
34-40-46
34-40-49
34-38-44
34-40-48
31-7/16
30-11/16
43-5/16
10-1/8
8-1/4
10-1/4
11-5/8
11-3/4
12-13/16
27
23
37
1/2
5/8
Munsell No. 1.0Y 9.2/0.2
Dimension
Remote Controller
Type
Refrigerant
Type
O.D.: 5/8
Wireless Remote (Optional Wired Controller)
R410A
Gas Side O.D.
3/8
In.
Liquid Side O.D.
Connection Method
22,000
53
23,200
53
dB(A)
Sound Level Pressure
(Heating) (Lo-Med-Hi) *2
Refrigerant Pipe
16,200
30
20,100
30
15,000
30
18,000
30
AC 208-230V
DC12-24V
Wireless Type (Optional Wired Controller: DC12V)
1.0
0.76
152-240-353
162-226-381
268-328-381
134-215-318
144-202-350
240-293-342
159-240-353
166-240-399
254-314-381
152-229-307
134-205-275
159-222-307
Fan
MSZ-A24NA
INVERTER
1 Phase, 60Hz, 208 / 230V *4
Indoor - Outdoor S1-S2
Indoor - Outdoor S2-S3
Indoor - Remote Controller
MCA *4
Fan Motor
Voltage
12,000
24
13,600
30
MSZ-A17NA
1/4
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
For data on specific indoor unit combinations, see pages 21 to 23.
SEZ DUCTED INDOOR UNIT
(FOR MXZ-2A20/2B2 0 / 3 A 3 0 / 4 A 3 6 N A O U T D O O R U N I T S )
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Heating at 47˚ F *2
Power Supply
SEZ-KD09NA
Rated Capacity
Btu/h
Total Input
W
Rated Capacity
Btu/h
Total Input
W
9,000
12,000
60
70
10,900
13,600
40
50
Phase, Cycle, Voltage
Fan
Fan Motor Output
W
Airflow (Lo-Med-Hi)
CFM
External Static Pressure *3
In.W.G.
W: In.
31-1/8
27-9/16
7-7/8
In.
423-529-635
23-28-33
30-34-37
Galvanized-steel Sheets
39
H: In.
Field Drainpipe Size
Connection Method
353-441-529
D: In.
H: In.
Liquid Side O.D.
247-317-388
0.02-0.06-0.14-0.20
23-26-30
Lbs.
*3 External static pressure is factory
set to 0.06" W.G. Adjustable via the
PAR-21MAA
96
194-247-317
40
Notes:
*1 Cooling-Indoor: D.B. 80º F (26.7º C),
W.B. 67º F (19.4º C); Outdoor: D.B. 95º F
(35º C), W.B. 75º F (23.9º C).
*2 Heating-Indoor: D.B. 70º F (21.1º C),
W.B. 60º F (15.6º C); Outdoor: D.B. 47º F
(8.3º C), W.B. 43º F (6.1º C).
1.0
dB(A)
Drain Lift Mechanism (Included)
Type
Type
Gas Side O.D.
20,100
70
DC24V
A
Weight
Refrigerant Pipe
18,000
AC 208- 230V
MCA *4
Dimension
17,200
90
Indoor - Outdoor S2-S3
Sound Pressure Levels (Lo-Med-Hi)
External Finish
Remote Controller
Refrigerant
15,000
1-Phase, 60Hz, 208 / 230V *4
Indoor - Outdoor S1-S2
Voltage
SEZ-KD18NA
INVERTER
SEZ-KD12NA
SEZ-KD15NA
For Use with all MXZ-Series
46
30-34-38
51
21-11/16
*4 Indoor units receive power
from outdoor units through fieldsupplied interconnected wiring.
46-7/8
Specifications are subject to change
without notice.
60
LIMITED WARRANTY Seven-year
warranty on compressor. Five-year
warranty on parts.
**For data on specific indoor unit
combinations, see page 21 - 23
O.D.: 1-1/4
Wired Controller (PAR-21MAA)
R410A
In.
3/8
1/2
1/4
Flared/Flare
17
Multiple Rooms With An Added Bonus
The MXZ-2B20NA system, when combined with
two MSZ-GE09NA indoor units, is ENERGY
STAR rated and qualifies for the government’s
Economic Stimulus Tax Credit of up to $1,500.
Visit www.mitsubishicomfort.com/taxcredit for
more details on the qualified systems or ask
your contractor.
Visit www.dsireusa.org for any possible local
rebate opportunities from state or utility
companies.
This is only the start. The system continues to
be rated with a wide variety of combinations of
indoor units to handle a number of applications.
MULTI-ROOM MXZ-2 B20NA
INVERTER HEAT PUMP
Model Name
18,000/20,000
Capacity Range
Total Input
Btu/h
W
7,800-20,000
2,190 (630-2,190)
Rated Capacity
Heating at 47° F
*2 Non-ducted/ Capacity Range
Ducted
Total Input
Btu/h
22,000/22,000
Rated Capacity
Heating at 17° F Rated Total Input
*3 Non-ducted/
Maximum Capacity
Ducted
Maximum Total Input
Btu/h
Power Supply
Voltage
Btu/h
W
W
Btu/h
W
Phase, Cycle, Voltage
Indoor - Outdoor S1 - S2
15
MOCP
A
20
Fan Motor
F.L.A.
R.L.A.
Airflow (Cooling/Heating)
Refrigerant Control
10.1
15
1,640
Linear Expansion Valve
Reverse Cycle
51
*5 Data from combination of two Indoor Units MSZ-GE09NA.
33-1/16
D: In.
13
Weight
H: In.
Lbs.
27-15/16
130
R410A
Charge
Lbs., Oz.
Oil
Type (fl. oz.)
Gas Side O.D.
In.
3/8
Liquid Side O.D.
In.
1/4
Height Difference (Max.)
Ft.
49/33
Length (Max.)
Ft.
*8 Indoor units receive power from outdoor units through
field-supplied interconnected wiring.
*9 49’ Applies to installations where the outdoor unit is
installed below the indoor unit.
5, 15
NEO22 (23.7)
Power factor equals 97 percent.
Specifications are subject to change without notice.
LIMITED WARRANTY | Seven-year warranty
on compressor. Five-year warranty on parts.
164
Flared/Flared
SEER and HSPF Ratings
Rated C o m b i n a t i o n s
The charts below indicate the rated capacities for each of the
MXZ systems.
MXZ-2B20NA Combinations
With the addition of ducted indoor units
to the MXZ-Series, the number of available combinations has greatly expanded.
The installation specifications and rated
capacities vary on systems using wallmounted only (MSZ-GE and/or MSZ-FE),
ducted only (SEZ-KD) or a combination of
unit styles.
*6 Data from combination of Indoor Units MSZ-A09NA, MSZA09NA and MSZ-A12NA.
*7 Data from combination of four MSZ-A09NA Indoor Units.
Associated With Indoor Unit Model
Indoor/Outdoor
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C),
W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C),
W.B. 15º F (-9º C).
*4 Refer to pages 12 and 13 for Indoor Unit specifications.
Dimensions
Type
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C),
W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C),
W.B. 43º F (6º C).
49
Munsell No. 5Y 8.0 / 1.0
Type
18
0.96
DC INVERTER-driven Twin Rotary
CFM
Defrost Method
NOTES: Test conditions are based on AHRI 210/240. One
indoor unit is turned off during low-speed testing under
the new test conditions. Systems actually exhibit higher
energy efficiencies during normal operation.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C),
W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º
F (24º C).
L.R.A.
W: In.
Connection Method
1,500
DC12-24V
External Finish Color
Refrigerant Pipe Length
14,500
A
Sound Pressure Level at Heating *2 dB(A)
Refrigerant Pipe
*Compatible with the MSZ-A, MSZ-FD, MSZ-GE, MSZ-FE and
SEZ series indoor units
1,350/1,430
MCA
Sound Pressure Level at Cooling *1 dB(A)
Refrigerant
12,500/12,500
AC 208 / 230V
Indoor - Outdoor S2 - S3
Compressor
Remote Controller
8,500-25,500
1,780 (520-1,780)
1-phase, 60Hz, 208 / 230V *8
Model (Type)
Outdoor Unit *4
INVERTER
MXZ-2B20NA *5
Btu/h
Cooling *1 Nonducted/Ducted
Outdoor Unit
Outdoor Unit
Rated Capacity
9+9
Model
MXZ-2B20NA
9 + 12
9 + 15
12 + 12
MXZ-2B20NA
ENERGY STAR &
TAX CREDIT
Indoor Unit Type
SEER
HSPF
Non-ducted
16
8.5
Ducted and Non-ducted
15.5
8.5
Ducted
15.5
8.5
2 x MSZ-GE09NA
18
8.9
MSZ WALL-MOUNTED INDOOR UNITS
(FOR MXZ-2B20N A O U T D O O R U N I T )
Model Name
Cooling *1
Heating at 47° F *2
Power Supply
Indoor Unit
Rated Capacity
Btu/h
Total Input
W
Rated Capacity
Btu/h
Total Input
W
MSZ-GE09NA
MSZ-FE09NA
MSZ-GE12NA
MSZ-FE12NA
MSZ-GE15NA
MSZ-GE18NA
9,000
9,000
12,000
12,000
14,000
17,200
22
18
22
24
45
43
10,900
10,900
14,400
13,600
18,000
21,600
23
24
23
30
31
37
Phase, Cycle, Voltage
1-phase, 60Hz, 208 / 230V *3
Indoor - Outdoor S1 - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
Voltage
DC12-24V
Indoor - Remote Controller
Wireless Type (Optional Wired Controller: DC 12V)
MCA
A
1.0
Fan Motor
F.L.A.
DRY
(CFM)
WET
(CFM)
0.76
Airflow at Cooling (QuietLo-Med-Hi-Super Hi or
Lo-Med-Hi-Powerful)*1
Fan
Airflow at Heating (QuietLo-Med-Hi-Super Hi or
Lo-Med-Hi-Powerful) *2
Sound Pressure Level at Cooling (Quiet-Lo-Med-HiSuper Hi or Lo-Med-Hi-Powerful) *1
Sound Pressure Level at Heating (Quiet-Lo-Med-HiSuper Hi or Lo-Med-Hi-Powerful) *2
145-170-237-321-399
162-226-339-381
145-170-237-321-399
162-226-381-410
205-272-335-420-533
230-275-339-420-533
109-134-201-286-364
144-202-307-343
109-134-201-286-364
144-202-350-367
170-237-300-385-498
194-240-304-385-498
WET
(CFM)
145-170-237-321-406
166-240-367-381
145-170-237-321-406
166-240-399-420
205-247-304-367-463
230-275-339-431-512
dB(A)
19-22-30-37-43
22-31-39-42
19-22-30-37-45
22-33-43-45
26-32-38-44-49
28-33-38-44-49
dB(A)
19-22-30-37-43
22-31-40-42
19-22-30-37-43
22-23-43-44
26-30-35-40-46
28-33-38-43-48
External Finish Color
Munsell No. 1.0Y 9.2 / 0.2
W: In.
31-7/16
D: In.
Dimension Unit
9-1/8
10-1/8
9-1/8
H: In.
Weight Unit
Lbs.
Field Drainpipe Size O.D.
In.
Remote Controller
Type
Refrigerant
Type
Gas Side O.D.
In.
Liquid Side O.D.
In.
Refrigerant Pipe
Connection Method
INVERTER
10-1/8
9-1/8
27
22
11-5/8
22
27
22
5/8
Wireless Remote (Optional Wired Controller)
R410A
3/8
1/2
1/4
Indoor/Outdoor
Flared/Flared
*MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units.
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Indoor units receive power from outdoor units through field-supplied wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
For data on specific indoor unit combinations, see pages 21.
SEZ DUCTED INDOOR UNIT
(FOR MXZ-2A20/2B2 0 / 3 A 3 0 / 4 A 3 6 N A O U T D O O R U N I T S )
Indoor Unit
Outdoor Unit
Model Name
Cooling *1
Heating at 47˚ F *2
Power Supply
SEZ-KD09NA
Rated Capacity
Btu/h
Total Input
W
Rated Capacity
Btu/h
Total Input
W
9,000
12,000
60
70
10,900
13,600
40
50
Phase, Cycle, Voltage
Fan
Fan Motor Output
W
Airflow (Lo-Med-Hi)
CFM
External Static Pressure *3
In.W.G.
W: In.
31-1/8
27-9/16
7-7/8
In.
423-529-635
23-28-33
30-34-37
Galvanized-steel Sheets
39
H: In.
Field Drainpipe Size
Connection Method
353-441-529
D: In.
H: In.
Liquid Side O.D.
247-317-388
0.02-0.06-0.14-0.20
23-26-30
Lbs.
*3 External static pressure is factory
set to 0.06" W.G. Adjustable via the
PAR-21MAA
96
194-247-317
40
Notes:
*1 Cooling-Indoor: D.B. 80º F (26.7º C),
W.B. 67º F (19.4º C); Outdoor: D.B. 95º F
(35º C), W.B. 75º F (23.9º C).
*2 Heating-Indoor: D.B. 70º F (21.1º C),
W.B. 60º F (15.6º C); Outdoor: D.B. 47º F
(8.3º C), W.B. 43º F (6.1º C).
1.0
dB(A)
Drain Lift Mechanism (Included)
Type
Type
Gas Side O.D.
20,100
70
DC24V
A
Weight
Refrigerant Pipe
18,000
AC 208-230V
MCA *4
Dimension
17,200
90
Indoor - Outdoor S2-S3
Sound Pressure Levels (Lo-Med-Hi)
External Finish
Remote Controller
Refrigerant
15,000
1-Phase, 60Hz, 208 / 230V *4
Indoor - Outdoor S1-S2
Voltage
SEZ-KD18NA
INVERTER
SEZ-KD12NA
SEZ-KD15NA
For Use with all MXZ-Series
46
30-34-38
51
21-11/16
*4 Indoor units receive power
from outdoor units through field supplied interconnected wiring.
46-7/8
Specifications are subject to change
without notice.
60
LIMITED WARRANTY Seven-year
warranty on compressor. Five-year
warranty on parts.
**For data on specific indoor unit
combinations, see page 21 - 23
O.D.: 1-1/4
Wired Controller (PAR-21MAA)
R410A
In.
3/8
1/2
1/4
Flared/Flare
19
Middle
Middle
10
10
[0.04]
[0.04]
Low
Low
Rated
Ratedpoint
point
Low
Low
Rated
Ratedpoint
point
External static pressure [in.WG](Pa)
External static pressure [in.WG](Pa)
External
static
pressure
[in.WG](Pa)
External
static
pressure
[in.WG](Pa)
6
7
8
[212]
[247]
[282]
Airflow rate(m3/min)[CFM]
9
[318]
Rated
Rated
point
point
Low
Low
10
10
LowLow
[0.04]
[0.04]
0 0
600 6
7 7
8 8
9 9
10 10
11 11
44
55
6[282]
6
7[318]
7
88[353] [388]
99[388]
[212][212]
[247][247]
[282]
[318]
[353]
[141]
[141]
[176]
[176]
[212]
[212]
[247]
[247]
[282]
[318]
[318]
3
3 [282]
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
33
/min)[CFM]
/min)[CFM]
Airflow
Airflowrate(m
rate(m
10
[353]
208/230V 60Hz
(External
static pressure 0.20[in.WG](50Pa)) 208/230V 60Hz
50
[0.20]
80
[0.32]
High
Limit
3050
[0.20]
[0.12]
Rated point
40
[0.16]
20
[0.08]
10
[0.04]
10
[0.04]
00
4
6
[141]
[212]
1210
[353]
424]
High
Middle
20
30
[0.08]
[0.12]
Middle
Low
Rated point
6
7
8
8
9
10
[212]
[247]
[282]
[282]
[318]
[353]
Airflow rate(m3/min)[CFM]
Airflow rate(m3/min)[CFM]
9
11
[318]
10
12
[353]
[388]
[424]
208/230V 60Hz
(External
static pressure 0.20[in.WG](50Pa)) 208/230V 60Hz
50
High
Rated point
40
[0.16]
20
[0.08]
30
[0.12]
High
Middle
Middle
20
10
[0.08]
[0.04]
Low
10
[0.04]
9
10
11
12
13
14
15
[318]7 [353] 8 [388]
[424]
[459]
[494] 11 [530]
9
10
[247]
[282]Airflow[318]
[353]
[388]
rate(m3/min)[CFM]
3
Airflow rate(m /min)[CFM]
16
[565]
12
[424]
SEZ-KD18NA
SEZ-KD15NA
(External static pressure 0.06[in.WG](15Pa))
208/230V 60Hz
(External
static pressure 0.20[in.WG](50Pa)) 208/230V 60Hz
50
External
static
pressure
External
static
pressure[in.WG](Pa)
[in.WG](Pa)
[0.20]
80
[0.32]
70
40
[0.28]
[0.16]
High
60
[0.24]
30
50
[0.12]
[0.20]
40
[0.16]
20
[0.08]
30
[0.12]
10
20
[0.08]
[0.04]
Middle
Middle
Low
Low
High
Rated point
Rated point
Limit Limit
10
[0.04]
0
10
11
12
13
14
15
16
17
18
19
0 9
[318] [353] [388] [424] [459] [494] [530] [565] [600] [636] [671]
8
9
10
11
12
13
14
15
16
Airflow [424]
rate(m3/min)[CFM]
[282]
[318]
[353]
[388]
[459]
[494]
[530]
[565]
3
Airflow rate(m /min)[CFM]
20SEZ-KD18NA
High High
HighHigh
pointpoint
Middle
MiddleRatedRated
Middle
Middle
8
9
(External
(External
static
static
pressure
pressure
0.14[in.WG](35Pa))
0.14[in.WG](35Pa))
208/230V
208/230V
60Hz
60Hz
80 80
[0.32]
[0.32]
40 40
[0.16]
[0.16]
20
20
[0.08][0.08]
30 30
[0.12]
[0.12]
60 60
[0.24]
[0.24]
HighHigh
50 50
[0.20]
[0.20]
40 40
[0.16]
[0.16]
Middle
Middle
30 30
[0.12]
[0.12]
Rated
Rated
point
point
LowLow
12 12
Limit Limit
High High
Rated
Rated
point
point HighHigh
Middle
Middle
Middle
Middle
RatedRated
pointpoint
Low Low
(External
(External
staticstatic
pressure
pressure
0.20[in.WG](50Pa))
0.20[in.WG](50Pa))
208/230V
208/230V
60Hz60Hz
50 50
[0.20]
80[0.20]
80
[0.32][0.32]
Limit
Limit
Limit
Limit
70 70
[0.28]
40[0.28]
40
[0.16]
[0.16]
High High
HighHigh
60 60
[0.24][0.24]
30 30
50
50
[0.12]
[0.12]
[0.20]
[0.20]
40 40
[0.16][0.16]
20 20
[0.08]
[0.08]
30 30
[0.12][0.12]
RatedRated
pointpoint
Middle
Middle
Middle
Middle
LowLow
20
20
10 10
[0.08]
[0.08]
[0.04]
[0.04]
Low Low
Rated
Rated
point
point
10 10
[0.04][0.04]
0 0
0 9 09 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19
[318]
[353]
[388]
[424]
[459][459]
[530]
[530]
[565]
[600]
[636][636]
8 [318]
8
9[353]
9 [388]
10[424]
10
11
11[494]
12 [494]
12
13
13[565]
14[600]
14
15
15[671]
16[671]
16
3
3
[282] [282]
[318] [318]
[353] [353]
[388]
[388]
[424]
[424]
[459]
[459]
[494] [494]
[530] [530]
[565] [565]
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
3
3
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(mrate(m
SEZ-KD18NA
SEZ-KD18NA
(External
(External
static
static
pressure
pressure
0.20[in.WG](50Pa))
0.20[in.WG](50Pa))
208/230V
208/230V
60Hz
60Hz
80 80
[0.32]
[0.32]
Limit
Limit
70 70
[0.28]
[0.28]
HighHigh
60 60
[0.24]
[0.24]
50 50
[0.20]
[0.20]
Middle
Middle
40 40
[0.16]
[0.16]
Rated
Rated
point
point
30 30
[0.12]
[0.12]
20 20
[0.08]
[0.08]
10 10
[0.04]
[0.04]
0
0
3
3
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
11 11
SEZ-KD18NA
SEZ-KD18NA
SEZ-KD15NA
SEZ-KD15NA
(External
(External
static
static
pressure
pressure
0.06[in.WG](15Pa))
0.06[in.WG](15Pa))
208/230V
208/230V
60Hz
60Hz
10 10
[0.04]
[0.04]
0
9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19
[318][318]
[353][353]
[388][388]
[424][424]
[459][459]
[494][494]
[530][530]
[565][565]
[600][600]
[636][636]
[671][671]
10 10
LowLow
10 10
[0.04]
[0.04]
0
0
9 10 10 11 11 12 12 13 13 14 14 15 15 16 16
0 80 8 9
[282]
[424]
[565]
6 [282]
6 [318]7[318]
7[353] [353]
8[388]
8 [388]
9 [424]
9 [459]
10[459]
10[494] [494]
11 [530]
11 [530]
12 12[565]
3
3
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
[212][212] [247][247]
[282][282]
[318]
[318]
[353]
[353] [388][388] [424][424]
3
3
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
Limit
Limit
70 70
[0.28]
[0.28]
9
Limit
Limit
LowLow
0
9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19
[318][318]
[353][353]
[388][388]
[424][424]
[459][459]
[494][494]
[530][530]
[565][565]
[600][600]
[636][636]
[671][671]
Note: ESP @ 208/230V, 60 Hz. See manual for Static Performance Curve, including @ 0.02 in W.G.
(External static pressure 0.20[in.WG](50Pa)) 208/230V 60Hz
8
60 60
[0.24]
[0.24]
Low Low
SEZ-KD18NA
SEZ-KD18NA
20 20
[0.08]
[0.08]
7
70 70
40 40
[0.28]
[0.28]
[0.16]
[0.16]
LowLow
Rated
Rated
point
point
10 10
[0.04][0.04]
0 0
0 9 0 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19
[318]
[388]
[388]
[424]
[459]
[494]
[565]
8 [318]
8[353]
9 [353]
9 10
10[424]
11[459]
11
12 [494]
12[530]
13[530]
13 [565]
14 [600]
14[600]
15[636][636]
15 [671]
16 [671]
16
3
3
[282] [282]
[318] [318]
[353] [353]
[388]
[388]
[424]
[424]
[459]
[459]
[494] [494]
[530] [530]
[565] [565]
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
3
3
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(mrate(m
Limit
Limit
7
55 [247]
66 [282] 7
7 [318] 88
10
[247]
[282]
[318]
[353][353] 99[388][388] 10
[424][424]
[176]
[176]
[212]
[212]
[247]
[247] 3 [282]
[318]
[318]
[353]
[353]
3[282]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
3 3 /min)[CFM]
/min)[CFM]
/min)[CFM]
Airflow
Airflowrate(m
rate(m
[0.20][0.20]
80 80
[0.32]
[0.32]
Limit
Limit
20 20
[0.08]
40 [0.08]
40
[0.16][0.16]
30 30
[0.12][0.12]
10 10
[0.04]
20 [0.04]
20
[0.08][0.08]
Rated point
Low
LowLow
50 50static
(External
(External
static
pressure
pressure
0.20[in.WG](50Pa))
0.20[in.WG](50Pa))
208/230V
208/230V
60Hz
60Hz
Low Low
50 50
[0.20][0.20]
Rated
Rated
point
point
SEZ-KD15NA
SEZ-KD15NA
(External
(External
staticstatic
pressure
pressure
0.06[in.WG](15Pa))
0.06[in.WG](15Pa))
208/230V
208/230V
60Hz60Hz
SEZ-KD12NA
SEZ-KD12NA
20
10 2010
[0.08]
[0.08]
[0.04]
[0.04]
[0.16]
80 [0.16]
80
[0.32][0.32]
External static pressure [in.WG](Pa)
External static pressure [in.WG](Pa)
External
Externalstatic
staticpressure
pressure[in.WG](Pa)
[in.WG](Pa)
30
50
[0.12]
[0.20]
0
0 8
[282]
6
[212]
Middle
Middle
30 30
[0.12]
60 [0.12]
60
[0.24][0.24]
60
[0.24]
16
12
565]
424]
Middle
Middle
70 70
[0.28][0.28]
Limit
70
40
[0.28]
[0.16]
High High
Rated
Rated
point
point HighHigh
(External
(External
staticstatic
pressure
pressure
0.14[in.WG](35Pa))
0.14[in.WG](35Pa))
208/230V
208/230V
60Hz60Hz
40 40
Limit
Middle
Middle
Low
Low
30 30
50 [0.12]
50
[0.12]
[0.20]
[0.20]
SEZ-KD18NA
SEZ-KD18NA
SEZ-KD15NA
SEZ-KD15NA
(External
(External
static
static
pressure
pressure
0.02[in.WG](5Pa))
0.02[in.WG](5Pa))
208/230V
208/230V
60Hz
60Hz
SEZ-KD15NA
SEZ-KD12NA
(External static pressure 0.06[in.WG](15Pa))
[0.20]
80
[0.32]
Limit
Limit
50 50
[0.20]
[0.20]
20 20
[0.08]
[0.08]
40 40
[0.16]
[0.16]
30 30
[0.12]
[0.12]
10 10
[0.04]
20[0.04]
20
[0.08]
[0.08]
0 0
006 6
44[212]
[212]
[141]
[141]
LowLow
RatedRated
pointpoint
10 10
[0.04]
[0.04]
0
0
9 10 10 11 11 12 12 13 13 14 14 15 15 16 16
08 0 8 9
[282]
[318]
[353]
[353]
[424]
[459]
[494] [494]
[565]
[565]
6 [282]
6 [318] 7
7
8[388]
8 [388]
9 [424]
9 [459]10
10
11[530]
11 [530]
12 12
3
3[353]
[212][212] [247][247]
[282][282]
[318][318]
[353] [388][388] [424][424]
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
3
3
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
Low
5
7
[176]
[247]
Limit Limit
70 70
[0.28]
[0.28]
30 30
[0.12][0.12]
60 60
[0.24]
[0.24]
HighHigh
Middle
Middle
20
20 10
10
[0.08]
[0.08]
[0.04]
[0.04]
12 12
[0.16][0.16]
80 80
[0.32]
[0.32]
External
static
pressure
[in.WG](Pa)
External
static
pressure
[in.WG](Pa)
Externalstatic
staticpressure
pressure[in.WG](Pa)
[in.WG](Pa)
External
70
[0.28]
40
[0.16]
60
[0.24]
Rated
Ratedpoint
point
40
40
[0.16]
[0.16]
20 20
[0.08]
[0.08]
30
30
[0.12]
[0.12]
10
10[424]
[424]
[353]
[353]
40
40 static
(External
(External
static
pressure
pressure
0.14[in.WG](35Pa))
0.14[in.WG](35Pa))
208/230V
208/230V
60Hz
60Hz
Limit
Limit
Limit
10
10
[0.04]
[0.04]
SEZ-KD15NA
SEZ-KD15NA
(External
(External
staticstatic
pressure
pressure
0.02[in.WG](5Pa))
0.02[in.WG](5Pa))
208/230V
208/230V
60Hz60Hz
SEZ-KD12NA
SEZ-KD12NA
SEZ-KD12NA
SEZ-KD09NA
(External static pressure 0.06[in.WG](15Pa))
High
High
60
60
[0.24]
[0.24]
30 30
[0.12]
[0.12]
50
50
[0.20]
[0.20]
External
static
pressure
External
static
pressure[in.WG](Pa)
[in.WG](Pa)
5
[176]
Middle
Middle
Limit
Limit
40
70
70 40
[0.16]
[0.16]
[0.28]
[0.28]
External static pressure [in.WG](Pa)
Low
Rated
Ratedpoint
point
HighHigh
Middle
Middle
External static pressure [in.WG](Pa)
External static pressure [in.WG](Pa)
4
[141]
Rated point
External static pressure [in.WG](Pa)
0
30
30
[0.12]
[0.12]
10 10
[0.04]
[0.04]
20
20
[0.08]
[0.08]
Middle
Limit
Limit
High
High
External
static
pressure
External
static
pressure[in.WG](Pa)
[in.WG](Pa)
20
[0.08]
10
[353]
50
50
[0.20]
[0.20]
20 20
[0.08]
[0.08]
40
40
[0.16]
[0.16]
High
30
[0.12]
80
80
[0.32]
[0.32]
External
static
pressure[in.WG](Pa)
[in.WG](Pa)
External
static
pressure
40
[0.16]
(External
(External
staticpressure
pressure0.20[in.WG](50Pa))
0.20[in.WG](50Pa)) 208/230V
208/230V60Hz
60Hz
[0.20]
[0.20]static
Limit
Limit
70
70
[0.28]
30[0.28]
30
[0.12]
[0.12]
60
60
[0.24]
[0.24]
10
10
[353]
[353]
(SEZ-KD12NA MODEL SHOWN)
External static pressure [in.WG](Pa)
80
80
[0.32]
[0.32]
99
[318]
[318]
SEZ-KD09NA
SEZ-KD09NA
50 50
(External
(External
staticpressure
pressure0.14[in.WG](35Pa))
0.14[in.WG](35Pa)) 208/230V
208/230V60Hz
60Hz
[0.16]
[0.16] static
Limit
66
77
88
[212]
[212]
[247]
[247]
[282]
[282]
33
/min)[CFM]
/min)[CFM]
Airflow
Airflowrate(m
rate(m
(External
(External
static
static
pressure
pressure
0.06[in.WG](15Pa))
0.06[in.WG](15Pa))
208/230V
208/230V
60Hz
60Hz
SEZ-KD09NA
SEZ-KD09NA
40 40
External static pressure [in.WG](Pa)
External static pressure [in.WG](Pa)
50
[0.20]
55
[176]
[176]
SEZ-KD12NA
SEZ-KD12NA
(External
(External
static
static
pressure
pressure
0.02[in.WG](5Pa))
0.02[in.WG](5Pa))
208/230V
208/230V
60Hz
60Hz
(External static pressure 0.06[in.WG](15Pa)) 208/230V 60Hz
00
44
[141]
[141]
10
10
[353]
[353]
SEZ-KD12NA
SEZ-KD12NA
SEZ-KD09NA
10
[0.04]
99
[318]
[318]
External
static
pressure
[in.WG](Pa)
External
static
pressure
[in.WG](Pa)
External
static
pressure
[in.WG](Pa)
66
77
88
[212]
[212]
[247]
[247]
[282]
[282]
33
/min)[CFM]
/min)[CFM]
Airflow
Airflowrate(m
rate(m
External
static
pressure
[in.WG](Pa)
External
static
pressure
[in.WG](Pa)
External static pressure [in.WG](Pa)
External static pressure [in.WG](Pa)
55
[176]
[176]
External static pressure [in.WG](Pa)
00
44
[141]
[141]
SEZ STATIC PERFORMANCE CURVES
RRECTED AIR FLOW
19
[671]
16
[565]
Middle
Middle
Ext
Ext
Ext
Ext
High
High
10
10
[0.04]
[0.04]
3
3
/min)[CFM]
/min)[CFM]
Airflow
Airflow
rate(m
rate(m
MXZ-3A30NA (3:1, 2:1)
O u t d o o r U n i t
MXZ SYSTEM COMBINATION OPTIONS
MXZ-2A20NA Combinations*
MSZ-A12NA
Indoor Unit
(using MSZ-A and/or MSZ-FD wall-mounted indoor units and/or
SEZ ducted indoor units)
Indoor Unit
(Unit A + Unit B)
Combinations
9+9
9 + 12
9 + 15
12 + 12
Cooling Capacity (Btu/h)
Heating Capacity (Btu/h)
Unit A
Unit B
Total
9,000
10,900
9,000
10,900
8,500
11,500
9,500
12,500
7,500
12,500
8,250
13,750
10,000
10,000
11,000
11,000
18,000
21,800
Power
Usage
(W)
1,740-1,780
1,820
2,150-2,190
1,780
(using MSZ-A and/or MSZ-FD wall-mounted indoor units and/or SEZ ducted indoor units)
Indoor Unit
(Unit A + Unit B + Unit C)
Combinations **
9 + 12
9 + 15
9 + 17
* Information provided at 208/230V. Refer to MXZ Outdoor Unit Service Manual
for detail specification and additional information per indoor unit combination.
Specifications are subject to change without notice.
9 + 18
9 + 24
12 + 12
MXZ-2B20NA (2:1)
O u t d o o r U n i t
12 + 15
12 + 17
12 + 18
15 + 15
15 + 17
MSZ-GE09NA
Indoor Units
15 + 18
17 + 17
17 + 18
(Two indoor units must be installed)
18 + 18
MXZ-2B20NA Combinations*
(using MSZ-GE and/or MSZ-FE wall-mounted indoor units and/
or SEZ ducted indoor units)
Indoor Unit
(Unit A + Unit B)
Combinations
Cooling Capacity (Btu/h)
Heating Capacity (Btu/h)
Unit A
Unit B
Total
9,000
9,000
18,000
Power
Usage
(W)
Wall:
Wall: 11,000
11,000
Ducted:
Ducted:
10,900
10,900
1,440 - 1,780
1,650 - 1,820
(All Ducted SEZ)
9 + 15
12 + 12
8,500
11,500
9,500
12,500
21,900
7,500
12,500
8,250
13,750
10,000
10,000
18,000
22,000
1,660 - 2,190
1,650 - 1,780
Specifications are subject to change without notice.
9,000
10,900
12,000
13,600
15,000
16,900
16,200
17,700
17,100
18,000
20,400
19,700
12,000
13,500
14,500
15,000
15,200
15,800
15,600
16,200
13,000
13,500
13,800
14,300
14,200
14,700
13,000
13,500
13,400
13,900
13,000
13,500
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Total
18,000
21,800
21,000
24,500
24,000
27,000
25,200
27,00
26,000
27,000
28,000
27,000
24,000
27,000
26,000
27,000
Power
Usage
(W)
1,800 - 1,840
1,700
2,000 - 2,040
1,980
2,500 - 2,540
2,200
2,700 - 2,720
2,200
2,820 - 2,840
2,200
3,200 - 3,220
1,980
2,500 - 2,540
2,200
2,800 - 2,840
2,160
2,800 - 2,820
2,140
2,820 - 2,840
2,140
2,800 - 2,840
2,120
2,800 - 2,820
2,110
2,820 - 2,840
2,110
2,800
2,100
2,820
2,100
2,840
2,100
Wall: 9,000
Wall: 9,000
Wall: 9,000
Ducted: 8,500 Ducted: 8,500 Ducted: 8,500
27,000 (All Wall-mounted MSZ)
25,500 (All Ducted SEZ)
26,500 - 26,000 (Combination)
2,860 - 2,950
Wall: 9,500
Wall: 9,500
Wall: 9,500
Ducted: 9,000 Ducted: 9,000 Ducted: 9,000
28,500 (All Wall-mounted MSZ)
27,000 (All Ducted SEZ)
28,000 - 27,500 (Combination)
2,180 - 2,240
Wall: 8,500
Wall: 8,500
Ducted: 8,000 Ducted: 8,000
11,400
28,400 (All Wall-mounted MSZ)
27,400 (All Ducted SEZ)
28,400 - 27,400 (Combination)
3,250 - 3,330
Wall: 8,600
Wall: 8,600
Ducted: 8,100 Ducted: 8,100
11,400
28,600 (All Wall-mounted MSZ)
27,600 (All Ducted SEZ)
28,600 - 27,600 (Combination)
2,180 - 2,220
Wall: 7,750
Wall: 7,750
Ducted: 7,250 Ducted: 7,250
12,900
28,400 (All Wall-mounted MSZ)
27,400 (All Ducted SEZ)
28,400 - 27,400 (Combination)
3,250 - 3,330
Wall: 7,800
Wall: 7,800
Ducted: 7,300 Ducted: 7,300
13,000
Wall: 7,300
Wall: 7,300
Ducted: 6,800 Ducted: 6,800
13,800
Wall: 7,350
Wall: 7,350
Ducted: 6,850 Ducted: 6,850
13,900
28,600 (All Wall-mounted MSZ)
27,600 (All Ducted SEZ)
28,100 (Combination)
2,180 - 2,220
Wall: 7,100
Wall: 7,100
Ducted: 6,600 Ducted: 6,600
14,200
28,400 (All Wall-mounted MSZ)
27,400 (All Ducted SEZ)
27,900 (Combination)
3,270 - 3,330
Wall: 7,200
Wall: 7,200
Ducted: 6,700 Ducted: 6,700
14,200
28,600 (All Wall-mounted MSZ)
27,600 (All Ducted SEZ)
28,100 (Combination)
2,180 - 2,220
9 + 9 + 17
1,630 - 2,190
1,650 - 1,780
11,000
11,000
* Information provided at 208/230V. Refer to MXZ Outdoor Unit
Service Manual for detail specification and additional information
per indoor unit combination.
9,000
10,900
9,000
10,900
9,000
10,100
9,000
9,300
8,900
9,000
7,600
7,300
12,000
13,500
11,500
12,000
10,800
11,200
10,400
10,800
13,000
13,500
12,200
12,700
11,800
12,300
13,000
13,500
12,600
13,100
13,000
13,500
9 + 9 + 15
(Combination)
9 + 12
Unit A
9 + 9 + 12
(All Wall-mounted
MSZ)
21,800
Cooling Capacity (Btu/h)
Heating Capacity (Btu/h)
Unit B
Unit C
9+9+9
22,000
9+9
(At least two indoor units
must be installed)
MXZ-3A30NA Combinations*
9+9
20,000
22,000
MSZ-A09NA
Indoor Unit
9 + 9 + 18
28,600 (All Wall-mounted MSZ)
27,600 (All Ducted SEZ)
28,600 - 27,600 (Combination)
28,400 (All Wall-mounted MSZ)
27,400 (All Ducted SEZ)
27,900 (Combination)
2,180 - 2,200
3,250 - 3,310
* Information provided at 208/230V. Refer to MXZ Outdoor Unit Service Manual for detail specification and additional information per indoor unit combination.
** Sizes 17 and 24 only available in MSZ-A17 and MSZ-A24 wall-mounted indoor unit style, respectively. Size 18 only available in SEZ-KD18 ducted indoor unit style specification and additional information per indoor unit combination.
Specifications are subject to change without notice.
21
MXZ-4A36NA Combinations*
(using MSZ-A and/or MSZ-FD wall-mounted indoor units and/or SEZ ducted indoor units)
Indoor Unit
(Unit A + Unit B + Unit C +
Unit D) Combinations **
Cooling Capacity (Btu/h)
Unit A
Unit B
Heating Capacity (Btu/h)
Unit C
Unit D
–
27,000 (All Wall-mounted MSZ)
25,800 (All Ducted SEZ)
26,600 - 26,200 (Combination)
2,860 - 2,950
Wall: 10,800 Wall: 10,800 Wall: 10,800
Ducted: 10,400 Ducted: 10,400 Ducted: 10,400
–
32,400 (All Wall-mounted MSZ)
31,200 (All Ducted SEZ)
32,000 - 31,600 (Combination)
2,700
Wall: 9,000
Wall: 9,000
Ducted: 8,600 Ducted: 8,600
12,000
–
30,000 (All Wall-mounted MSZ)
29,200 (All Ducted SEZ)
30,000 - 29,200 (Combination)
3,270 - 3,350
Wall: 10,000 Wall: 10,000
Ducted: 9,600 Ducted: 9,600
12,400
–
32,400 (All Wall-mounted MSZ)
31,600 (All Ducted SEZ)
32,400 - 31,600 (Combination)
2,700
Wall: 8,800
Wall: 8,800
Ducted: 8,400 Ducted: 8,400
14,500
–
32,100 (All Wall-mounted MSZ)
31,300 (All Ducted SEZ)
32,100 - 31,300 (Combination)
3,500 - 3,580
Wall: 8,900
Wall: 8,900
Ducted: 8,500 Ducted: 8,500
14,600
–
Wall: 8,200
Wall: 8,200
Ducted: 7,800 Ducted: 7,800
15,700
–
Wall: 8,400
Wall: 8,400
Ducted: 8,000 Ducted: 8,000
15,600
–
32,400 (All Wall-mounted MSZ)
31,600 (All Ducted SEZ)
32,000 (Combination)
2,700
Wall: 8,100
Wall: 8,100
Ducted: 7,700 Ducted: 7,700
15,900
–
32,100 (All Wall-mounted MSZ)
31,300 (All Ducted SEZ)
31,700 (Combination)
3,520 - 3,580
Wall: 8,100
Wall: 8,100
Ducted: 7,700 Ducted: 7,700
16,200
–
32,400 (All Wall-mounted MSZ)
31,600 (All Ducted SEZ)
32,000 (Combination)
2,700
Wall: 6,900
Wall: 6,900
Ducted: 6,500 Ducted: 6,500
18,300
–
32,100 (All Wall-mounted MSZ)
31,300 (All Ducted SEZ)
31,700 (Combination)
3,500 - 3,560
Wall: 7,800
Wall: 7,800
Ducted: 7,400 Ducted: 7,400
16,800
–
32,400 (All Wall-mounted MSZ)
31,600 (All Ducted SEZ)
32,000 (Combination)
2,700
Wall: 8,700
Ducted: 8,300
11,700
11,700
–
32,100 (All Wall-mounted MSZ)
31,700 (All Ducted SEZ)
32,100 - 31,700 (Combination)
3,500 - 3,570
Wall: 9,400
Ducted: 9,000
11,500
11,500
–
32,400 (All Wall-mounted MSZ)
32,000 (All Ducted SEZ)
32,400 - 32,000 (Combination)
2,700
Wall: 8,000
Ducted: 7,600
10,700
13,400
–
32,100 (All Wall-mounted MSZ)
31,700 (All Ducted SEZ)
32,100 - 31,700 (Combination)
3,500 - 3,570
Wall: 8,300
Ducted: 7,900
10,400
13,700
–
32,400 (All Wall-mounted MSZ)
32,000 (All Ducted SEZ)
32,400 - 32,000 (Combination)
2,700
Wall: 7,600
Ducted: 7,200
10,100
14,400
–
32,100 (All Wall-mounted MSZ)
31,700 (All Ducted SEZ)
32,100 - 31,700 (Combination)
3,500 - 3,550
Wall: 7,900
Ducted: 7,500
9,900
14,600
–
32,400 (All Wall-mounted MSZ)
32,000 (All Ducted SEZ)
32,400 - 32,000 (Combination)
2,700
Wall: 7,500
Ducted: 7,100
10,000
14,600
–
32,100 (All Wall-mounted MSZ)
31,700 (All Ducted SEZ)
32,100 - 31,700 (Combination)
3,520 - 3,570
–
32,400 (All Wall-mounted MSZ)
32,000 (All Ducted SEZ)
32,400 - 32,000 (Combination)
2,700
Wall: 9,000
Wall: 9,000
Wall: 9,000
Ducted: 8,500 Ducted: 8,500 Ducted: 8,500
9+9+9
9 + 9 + 12
9 + 9 + 15
9 + 9 + 17
9 + 9 + 18
9 + 9 + 24
9 + 12 + 12
9 + 12 + 15
9 + 12 + 17
9 + 12 + 18
32,400 (All Wall-mounted MSZ)
31,600 (All Ducted SEZ)
32,400 - 31,600 (Combination)
32,100 (All Wall-mounted MSZ)
31,300 (All Ducted SEZ)
31,700 (Combination)
2,700
3,500 - 3,560
Wall: 7,600
Ducted: 7,200
9,900
14,900
Wall: 7,500
Ducted: 7,100
12,300
12,300
32,100 (All Wall-mounted MSZ)
31,700 (All Ducted SEZ)
32,100 - 31,700 (Combination)
3,500 - 3,570
Wall: 7,600
Ducted: 7,200
12,400
12,400
32,400 (All Wall-mounted MSZ)
32,000 (All Ducted SEZ)
32,400 - 32,000 (Combination)
2,700
Wall: 7,100
Ducted: 6,700
11,700
13,300
32,100 (All Wall-mounted MSZ)
31,700 (All Ducted SEZ)
32,100 - 31,700 (Combination)
3,500 - 3,570
Wall: 7,200
Ducted: 6,800
11,900
13,300
32,400 (All Wall-mounted MSZ)
32,000 (All Ducted SEZ)
32,400 - 32,000 (Combination)
2,700
9 + 15 + 15
9 + 15 + 17
22
Total
Power
Usage
(W)
* Information provided at 208V.
Refer to MXZ Outdoor Unit Service
Manual for detail specification and
additional information per indoor unit combination.
** Sizes 17 and 24 only available in MSZ-A17 and MSZ-A24
wall-mounted indoor unit style, respectively. Size 18 only available
in SEZ-KD18 ducted indoor unit
style specification and additional information per indoor unit combination.
Specifications are subject to change
without notice.
MXZ-4A36NA Combinations* (continued)
(using MSZ-A and/or MSZ-FD wall-mounted indoor units and/or SEZ ducted indoor units)
Indoor Unit
(Unit A + Unit B + Unit C +
Unit D) Combinations **
Cooling Capacity (Btu/h)
Unit A
Unit B
Heating Capacity (Btu/h)
Unit C
Unit D
-
32,100 (All Wall-mounted MSZ)
31,700 (All Ducted SEZ)
32,100 - 31,700 (Combination)
3,500 - 3,570
13,400
-
32,400 (All Wall-mounted MSZ)
32,000 (All Ducted SEZ)
32,400 - 32,000 (Combination)
2,700
12,700
12,700
-
12,700
12,700
-
12,600
12,900
-
32,100 - 31,700 (Combination)
3,520 - 3,550
12,700
12,800
-
32,400 - 32,000 (Combination)
2,700
3,540 - 3,570
Wall: 7,000
Ducted: 6,600
11,600
13,500
Wall: 7,100
Ducted: 6,700
11,900
9 + 15 + 18
9 + 17 + 17
9 + 17 + 18
9 + 18 + 18
12 + 12 + 12
12 + 12 + 15
12 + 12 + 17
12 + 12 + 18
12 + 15 + 15
Wall: 6,700
Ducted: 6,300
Wall: 7,000
Ducted: 6,600
Wall: 6,600
Ducted: 6,200
Wall: 6,900
Ducted: 6,500
Wall: 6,500
Ducted: 6,100
Wall: 6,800
Ducted: 6,400
Total
Power
Usage
(W)
32,100 (All Wall-mounted MSZ)
31,700 (Combination)
32,400 (All Wall-mounted MSZ)
32,000 (Combination)
3,500 - 3,530
2,700
12,800
12,800
-
31,700 (All Ducted SEZ)
32,100 (Combination)
12,800
12,800
-
32,400 - 32,000 (Combination)
2,700
10,700
10,700
10,700
-
32,100
3,500 - 3,560
10,800
10,800
10,800
-
32,400
2,700
9,900
9,900
12,300
-
32,100
3,500 - 3,560
9,700
9,700
13,000
-
32,400
2,700
9,400
9,400
13,300
-
32,100
3,500 - 3,540
9,300
9,300
13,800
-
32,400
2,700
9,300
9,300
13,500
-
32,100
3,520 - 3,560
9,200
9,200
14,000
-
32,400
2,700
9,100
11,500
11,500
-
32,100
3,500 - 3,560
9,000
11,700
11,700
-
32,400
2,700
Wall: 9,000
Wall: 9,000
Wall: 9,000
Wall: 9,000
Ducted: 8,600 Ducted: 8,600 Ducted: 8,600 Ducted: 8,600
36,000 (All Wall-mounted MSZ)
34,400 (All Ducted SEZ)
35,600 - 34,800 (Combination)
3,820 - 3,940
Wall: 9,000
Wall: 9,000
Wall: 9,000
Wall: 9,000
Ducted: 8,600 Ducted: 8,600 Ducted: 8,600 Ducted: 8,600
36,000 (All Wall-mounted MSZ)
34,400 (All Ducted SEZ)
35,600 - 34,800 (Combination)
3,100
Wall: 8,300
Wall: 8,300
Wall: 8,300
Ducted: 7,900 Ducted: 7,900 Ducted: 7,900
11,100
36,000 (All Wall-mounted MSZ)
34,800 (All Ducted SEZ)
36,000 - 34,800 (Combination)
3,820 - 3,930
Wall: 8,300
Wall: 8,300
Wall: 8,300
Ducted: 7,900 Ducted: 7,900 Ducted: 7,900
11,100
36,000 (All Wall-mounted MSZ)
34,800 (All Ducted SEZ)
36,000 - 34,800 (Combination)
3,100
Wall: 7,700
Wall: 7,700
Wall: 7,700
Ducted: 7,300 Ducted: 7,300 Ducted: 7,300
12,900
36,000 (All Wall-mounted MSZ)
34,800 (All Ducted SEZ)
36,000 - 34,800 (Combination)
3,820 - 3,930
Wall: 7,700
Wall: 7,700
Wall: 7,700
Ducted: 7,300 Ducted: 7,300 Ducted: 7,300
12,900
36,000 (All Wall-mounted MSZ)
34,800 (All Ducted SEZ)
36,000 - 34,800 (Combination)
3,100
Wall: 7,700
Wall: 7,700
Ducted: 7,300 Ducted: 7,300
10,300
36,000 (All Wall-mounted MSZ)
35,200 (All Ducted SEZ)
36,000 - 35,200 (Combination)
3,820 - 3,920
10,300
36,000 (All Wall-mounted MSZ)
35,200 (All Ducted SEZ)
36,000 - 35,200 (Combination)
3,100
9+9+9+9
9 + 9 + 9 + 12
9 + 9 + 9 + 15
10,300
9 + 9 + 12 + 12
Wall: 7,700
Wall: 7,700
Ducted: 7,300 Ducted: 7,300
10,300
MXZ-4A36NA (3:1, 4:1)
O u t d o o r U n i t
MSZ-A09NA
Indoor Units
* Information provided at 208V.
Refer to MXZ Outdoor Unit Service
Manual for detail specification and
additional information per indoor unit combination.
** Sizes 17 and 24 only available in MSZ-A17 and MSZ-A24
wall-mounted indoor unit style, respectively. Size 18 only available
in SEZ-KD18 ducted indoor unit
style specification and additional information per indoor unit combination.
Specifications are subject to change
without notice.
(At least three indoor
units must be installed)
SEZ-KD12NA
Indoor Units
23
Mitsubishi Electric Shizuoka Works
acquired ISO 9001 certification under
Series 9000 of the International Standard
Organization (ISO), based on a review
of quality warranties for the production
of air-conditioning equipment. The plant
also acquired environmental management
system standard ISO 14001 certification.
49385
Mitsubishi Electric Advanced Products Division
3400 Lawrenceville Suwanee Road
Suwanee, GA 30024
Phone: 888-467-7546 Fax: 800-658-1458
EC 97J1132
©2009 Mitsubishi Electric & Electronics USA, Inc. Mr Slim and H2i are registered trademarks of
Mitsubishi Electric. The three-diamond logo is a registered logo of Mitsubishi Electric Corporation.
*Hyper-Heating technology Patent Pending.
See complete warranty for terms, conditions and limitations. A copy is available from Mitsubishi Electric.
Please Recycle
Form No. MBROGEN-10-09-30M-V2 PD
For more information visit www.mitsubishicomfort.com
Download PDF