FAAC 400 CBAC, 400 CBAC4, 400 CBACR4, 400 SB1, 400 SBS1, 400 CBA, 400 CBAR, 402, 412, 415, 422, 620, 640, 750, 760 Gate Opener, 455 D Control Panel, 610, 615 Barrier Gate Opener Installation Manual
Below you will find brief information for Gate Opener 400 CBAC, Gate Opener 400 CBAC4, Gate Opener 400 SB1, Gate Opener 400 SBS1, Control Panel 455 D. The FAAC 400 Operator is an automatic gate operator for a swinging gate leaf. It can accommodate a gate leaf of up to 2000 lb (900 kg) and up to 20 ft (6 m) in length. The FAAC 455 D control panel is used to operate the FAAC 400 and 412 swing gate operators and FAAC 610 / 615 barrier gate operators.
Advertisement
Advertisement
T
H E
4 0 0 O
P E R A T O R A N D
4 5 5 D C
O N T R O L
P
A N E L
:
I
N S T A L L A T I O N
M
A N U A L
CONTENTS
Important Safety Information
Technical Data
Unpacking the Operator
The 400 Compact Operator General Characteristics
Installation Instructions
Prepare the Gate
Manual Release Mechanism
Install the Operator
Install the 455 D Control Panel
Exploded View, 400 CBAC
10
12
400 Parts List 13
The 455 D Control Panel General Description 14
Installing the 455 D Control Panel
Connect the Main Power Supply
Connect the Operator to the Control Panel
Check the Motor’s Direction of Rotation
14
14
15
15
6
6
7
7
2
4
5
6
Connect Other Devices
Set Other Operating Controls
Programming
Learning of Operating Times
Learning of Normal Times
Learning Times with Gatecoder
Automated Systems Test
Logic Tables of 455 D Control Panel
Maintenance
Safety in Gate Design
23
24
26
26
16
18
20
22
22
22
Troubleshooting
Limited Warranty
27
28
February, 20 09
400 O pe rator And
455 D Control Panel
Inst allation Manual
FAAC International, Inc.
303 Lexington Avenue
Cheyenne, WY 82007 www.faacusa.com
Page 2
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
I
MPORTANT
S
AFETY
I
NFORMATION
Both the installer and the owner and/or operator of this system need to read and understand this installation manual and the safety instructions supplied with other components of the gate system. This information should be retained by the owner and/or operator of the gate.
WARNING!
To reduce the risk of injury or death
1. RE AD AN D FOLLOW ALL
INSTRU CTIONS .
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE
PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate
MUST reverse on contact with a rigid object or stop when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate operator.
Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE
When installing photo-beams with this unit two things need to be considered.
1. Care should be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is in motion.
2. One or more photobeams shall be located where the risk of entrapment exists, such as the perimeter reachable by the moving gate leaf.
G
ATE
D
ESIGN
1. A gate is a potential traffic hazard, so it is important that you locate the gate far enough away from the road to eliminate the potential of traffic getting backed up. This distance is affected by the size of the gate, how often it is used, and how fast the gate operates.
2. The operator you choose to install on your gate must be designed for the type and size of your gate and for the frequency with which you use the operator.
3. Your gate must be properly installed and must work freely in both directions before the automatic operator is installed.
4. An automatic operator should be installed on the inside of the property/fence line. Do not install the operator on the public side of the property/fence line.
5. Pedestrians should not use a vehicular gate system.
Prevent such inappropriate use by installing separate gates for pedestrians.
6. Exposed, reachable pinch points on a gate are potentially hazardous and must be eliminated or guarded.
7. Outward swinging gates with automatic operators should not open into a public area.
8. The operating controls for an automatic gate must be secured to prevent the unauthorized use of those controls.
9. The controls for an automatic gate should be located far enough from the gate so that a user cannot accidentally touch the gate when operating the controls.
10. An automatic gate operator should not be installed on a gate if people can reach or extend their arms or legs through the gate. Such gates should be guarded or screened to prevent such access.
11. Be Sure to locate any switches that will activate the gates movement at least 10ft. From the gate(s)
I
NSTALLATION
1. If you have any question about the safety of the gate operating system, do not install this operator.
Consult the operator manufacturer.
2. The condition of the gate structure itself directly affects the reliability and safety of the gate operator.
3. Only qualified personnel should install this equipment. Failure to meet this requirement could cause severe injury and/or death, for which the manufacturer cannot be held responsible.
4. The installer must provide a main power switch that meets all applicable safety regulations.
5. Clearly indicate on the gate with the 2 warning signs that are included (visible from either side of the gate).
6. It is extremely unsafe to compensate for a damaged gate by increasing hydraulic pressure.
7. Devices such as reversing edges and photobeams must be installed to provide better protection for personal property and pedestrians. Install reversing devices that are appropriate to the gate design and gate application.
8. Before applying electrical power, be sure that the voltage requirements of the equipment correspond
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Page 3
U
SE to your supply voltage. Refer to the label on your operator system.
1. Use this equipment only in the capacity for which it was designed. Any use other than that stated should be considered improper and therefore dangerous.
2. When using any electrical equipment, observe some fundamental rules:
• Do not touch the equipment with damp or humid hands or feet.
•
Do not install or operate the equipment with bare feet.
• Do not allow small children or incapable persons to use the equipment.
3. If a gate system component malfunctions, turn off the main power before making any attempt to repair it.
4. Do not attempt to impede the movement of the gate. You may injure yourself as a result.
5. This equipment may reach high temperatures during operation; therefore, use caution when touching the external housing of the operator.
6. Learn to use the manual release mechanism according to the procedures found in this installation manual.
7. Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical supply.
8. To guarantee the efficiency of this equipment, the
U.L. C
LASS AND
FAAC O
PERATOR
Duty Cycle Typical Use Model
Class I: Residential Vehicular Gate Operator
402
422
750
760
412 400
620 640
415 390
Limited duty
• Home use
•
Small apartment building, for example, up to 4 units in a building, with limited public access
Class II: Commercial/General Access Vehicular Gate Operator
400 640
620
Continuous duty
•
•
Apartment buildings
Very public access
Class III: Industrial/Limited Access Vehicular Gate Operator
400 640
620
Continuous duty
• No public access
Class IV: Restricted Access Vehicular Gate Operator
620 640
Continuous duty
• Prison rated security
Page 4
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
T
ECHNICAL
D
ATA
Parameter
400 Model
Standard High Speed Slow Speed Long (EG)
Model
CBC
CBA
1
2
3
CBAC
4
SB
CBCR
CBAR
2
3
CBACR
4
SBS
1
CBC
2
SBS
CBAC
4
1
Apartment, subdivision, industrial, and commercial applications
Duty type
Duty cycle
80 Cycles/ Hour
Maximum leaf length
5
, ft (m)
Maximum leaf weight, lb (kg)
Maximum leaf swing, deg
Thrust and traction, lb (kg)
16 (5.4)
12 (3.6)
115
20 (6)
1300 (600)
900 (400) 2000 (900) 1500 (600) 2200 (600)
0–1760 (0–800)
18 (5.4) 22 (6)
125
90 deg opening time, sec
6
17
23
Operating temperature range, deg F (deg C)
18 27
-33 to 165 (-36 to 75)
Thermal cut out, deg F (deg C)
212 (100)
Hydraulic locking
Operator dimensions, l ´ w ´ h, in. (cm)
Operator weight, lb (kg)
Power voltage required, VAC
7
Opened and/or closed
None Opened and/or closed
40 X 3
5/16
X 3
5/16
(102 X 8.5 X 8.5)
47
1/2
X 3
5/16
X 3
5/16
(121 X 3 X 8.5)
19 (8.6) 23 (10.4)
115 VAC ±10%, 60 Hz, or 230 VAC +6 or -10%, 60 Hz
Amp Draw
Type of oil
Oil quantity, qt (l)
115V = 1.5 Amps; 230V = 1 Amp
Lubrication Engineers - MONOLEC 6115
2
1/3
1 The operator requires external locks.
2 Locks in the extended position. The hydraulic lock is a service device, not a security device.
3 Locks in the retracted position. The hydraulic lock is a service device, not a security device.
4 Locks in both the extended and retracted positions. The hydraulic lock is a service device, not a security device.
5 External locks are recommended if the gate leaves are 12 ft (3.6 m) or longer.
6 The time may vary ±10%.
7 Your standard 220 VAC power source meets the specification for 230 VAC, +6 or -10%.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Page 5
U
NPACKING THE
O
PERATOR
When you receive your 400 Operator, complete the following steps.
Inspect the shipping box for physical damage such as leaking oil or a torn carton. Then inspect the operator after you remove it from the box. Notify the carrier immediately if you note any damage. The carrier must witness the damage before you can file a claim.
As you unpack the box, insure that all the following parts included (see Figure 1). If you have ordered a kit
(a pair of operators), you will have twice the quantity of parts listed below (except where noted).
1 400 Operator - 1 each
2 Protective Cover - 1 each
3 Protective Cover Tie-Rods - 2 each
4 Protective Cover End Cap - 1 each
5 Rear Mounting Bracket - 1 each
6 Rear Mounting Plate (optional) - 1 each
7 Short Brass Pin with 8mm nut and washer - 1 each
8 Rear Fork - 1 each
9 Long Brass Pin with 8mm self-locking nut - 1 each
10 Swivel joint with jam nut and washer - 1 each
11 Front mounting bracket with nut and bolt
12 Locking cap cover and key for Manual Release - 1 each
13 Electric Power Cord - 1 each
14 Manual Release Knob - 1 each
1
10
2
13
3
4
14
Figure 1. Parts of the 400 Operator
Page 6
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
T
HE
400 O
PERATOR
G
ENERAL
C
HARACTERISTICS
The FAAC 400 Operator is an automatic gate operator for a swinging gate leaf. It can accommodate a gate leaf of up to 2000 lb (900 kg) and up to 20 ft (6 m) in length.
The self-contained 400 Operator is an electro-hydraulic unit consisting of an electric motor, a pump, a valve assembly, and a hydraulic cylinder, all housed in an anodized aluminum oil reservoir.
The 400 Operator can be used to swing the gate leaf inward or outward. Most versions provide hydraulic locking in at least one position, either opened or closed, depending on how it was ordered.
The hydraulic lock is a service device rather than a security device. Additional, external locks are recommended under the following conditions:
•
You are installing the Model 400 SB
•
The length of the gate leaf is 12 ft or more
•
The installation requires tight security
•
The site is subject to vandalism
•
The site is subject to strong or very gusty wind
•
You are installing a solid face gate
For gates with two leaves, two operators are installed, one on each leaf, and both are wired to one control panel. In such two-operator gate installations, one leaf can be programmed to open/ close slightly later than the other leaf to accommodate overlapping gate designs.
For its protection, the single-phase, bidirectional motor shuts off automatically if its operating temperature reaches 212 deg F (100 deg C). Also for the protection and proper operation of the 400 Operator, each gate leaf on which it is installed must have a fixed positive stop in both the opened and closed positions.
The 400 Operator also includes a key-operated Manual
Release mechanism and two bypass valves that precisely control the force applied to the gate leaf through the 400 Operator.
The Manual Release mechanism is a key-operated device that disengages (or engages) the hydraulic system of the 400 Operator. When the hydraulic system is disengaged, you can open and close the gate leaf by hand. Such manual operation of the gate is necessary during installation and useful during power failures. The two bypass valves are located beneath the locking cap.
You need to adjust the bypass valves to meet the safety standards of FAAC International, Inc. The standards state that the gate leaf should stop if it encounters a force of more than 33 lb (15 kg).
Additional reversing devices (such as inductive loops and photocells) should be installed to provide more complete protection for people and property.
The electronic control panel is a microprocessor-based controller that accepts a wide range of product accessories and reversing devices, thus allowing for flexible gate system design.
I
NSTALLATION
I
NSTRUCTIONS
Installing the 400 Operator involves preparing the gate, installing the operator(s), installing the control panel, and fine-tuning the pressure adjustments on the operator(s).
Note: The following installation instructions assume you are fully capable of installing an operator. This manual does not instruct you in designing a gate, installing a gate, or basic electrical wiring. The installation tasks discussed in this manual are tasks particular to the 400
Operator.
P
REPARING THE
G
ATE
Before installing the 400 Operator, you need to prepare the gate itself for the operator. Be sure to do the following things:
1. Make sure that the gate is plumb.
2. Make sure that the gate moves smoothly on its hinges without excessive friction by swinging it open and closed by hand. Lubricate all the gates’ moving parts.
3. Provide positive stops for the gate leaves in the fully open and fully closed positions (see
Figure 2).
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Figure 2. Positive Stops
M
ANUAL
R
ELEASE
M
ECHANISM
To move the gate operator manually during installation and/or power failures do the following procedures:
•
Lift the key lock cover (1) and insert the manual release key.
•
Turn the key (2) 90° clockwise to open the locking cap cover (3).
•
Lift up the cover.
•
Turn the manual release knob (4) counter-clockwise for (2) two full turns.
•
Open or close the gate leaf manually.
•
To return the operator to normal working status, do these steps in reverse order.
Page 7
I
NSTALLING THE
O
PERATOR
Installing the 400 operator consists of the following steps:
1. Attach the rear mounting bracket
2. Attach the mounting hardware
3. Attach the front mounting bracket
4. Attach the operator to the gate
5. Adjust the operator pressure
A
TTACH THE
R
EAR
M
OUNTING
B
RACKET
Attach the rear mounting bracket according to the dimensions in Figure 4.
WARNING!
You must achieve the A and B dimensions, as specified in Figure 4.
Modification of the rear bracket may be necessary to achieve these dimensions (I.e., cutting or extending the bracket provided)
If you have a steel gate post, weld the rear bracket directly to it. If the gate post is made of any other material, attach the optional mounting plate, with lag bolts or anchors, and weld the bracket to it.
For an outward swing gate refer to Figure 5.
Figure 3. Manual Release
Page 8
A
TTACH THE
M
OUNTING
H
ARDWARE
Insert the rear fork (hex cut up if you have a nylon rear fork) into the rear flange of the operator. Secure with long brass pin and self-locking nut.
Screw the jam nut onto the swivel joint. Slide the washer on next and screw the swivel joint halfway into the piston rod. Temporarily attach the front mounting bracket to the swivel joint with the nut and bolt provided.
A
TTACH THE
F
RONT
M
OUNTING
B
RACKET TO THE
O
PERATOR
Release the operator as shown in Fig. 3. Put the operator into position and attach the rear fork to the rear mounting bracket using the short brass pin, washer, and nut.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
For inward swing, pull the piston out completely and push back approximately ¼” (6mm). For outward swing, push the piston in completely and pull back out approximately ¼” (6mm).
Note:
Be sure that the operator is level and that the gate is against the close positive stop.
Hold the front mounting bracket flush against the gate.
Mark the location of the front mounting bracket.
Remove the operator from the gate. Remove the front mounting bracket from the swivel joint.
Note:
Clamping the front mounting bracket at the
marked location before checking the swing, as
instructed below, will ensure proper location of the
front mounting bracket.
Bolt or weld the front mounting bracket to the marked location on the gate.
WARNING!
Do not weld the front mounting bracket with the operator attached. Doing so will seriously damage the operator
.
Figure 4. Important mounting dimensions for inward swing 400 operators, top view
Dimensions, in. (cm)
Desired Swing
A 90-deg swing
115-deg swing
125-deg swing
B
C
D
E
90-deg swing
115-deg swing
125-deg swing
All Swings
90-deg swing
115-deg swing
125-deg swing
All Swings
400 Standard
High speed and
Slow speed models
5 (13)
4 (10)
N/A
5 (13)
4 3/4 (12)
N/A
38 3/16 (97)
Max 3 (8)
Max 2 (5)
N/A
400 Long
7 7/8 (20)* or 11 1/2 (29)**
5 3/4 (14.6)
5 1/8 (13)
7 1/2 (19)* or 3 (7.5)**
7 (17.8)
6 5/8 (17)
47 5/8 (121)
Max 5.5 (14)* or 9.5 (24)**
Max 3 1/2 (8.9)
Max 2 3/4 (7)
Must be less than A
* For A, B, and D, if you choose one of these values with one asterisk, then you must choose the other values with one asterisk.
** For A, B, and D, if you choose one of these values with two asterisks, then you must choose the other values with two asterisks.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Page 9
Dimensions, In. (cm)
400 Standard, Rapid, Slow and EG 400 Long (EG)
A
90°
5 (12.7)
115°
5 3/4 (14.6)
125°
4 3/4 (13)
Figure 5. Important mounting dimensions for outward swing 400 operators, top view
A
TTACH THE
O
PERATOR TO THE
G
ATE
Re-attach the operator to the mounting brackets. Once the operator is mounted and level, remove the vent screw from the bottom of the rear flange. (See Figure 1)
WARNING!
Failure to remove the vent screw may result in erratic operation of the operator or seals.
Slowly move the gate open and close.
WARNING!
The piston should not bottom out in either direction. Doing so will seriously damage operator.
Be sure that the gate reaches the positive stop before the piston bottoms out. Adjust the swivel joint if necessary.
Once the operator is secure, attach the protective cover to the front flange with the tie rods and end cap provided.
Note
: Lubricating the threads of the protective cover tie rods can prevent them from freezing up and breaking if operator is ever removed for
service.
Once the protective cover is installed, swing the gate to ensure that it does not contact the cover at any point of the swing.
Re-engage the operator by turning the red knob clockwise until snug. (see Figure 3)
B
C
D
E
5 (12.7)
27 9/16 (70)
No Limit
7 (17.8) 6 5/8 (17)
32 3/4 (93.19) 32 3/4 (83.19)
No Limit No Limit
Must be less than A
A
DJUST THE OPERATOR PRESSURES
The 400 Operator has an anti-crushing safety device
(operator pressure) which limits the operator’s force if an obstacle is encountered while the gate is moving.
To adjust the anti-crushing safety device do the following procedures:
•
Lift the key lock cover (figure 3) and insert the manual release key.
•
Turn the key 90° clockwise to open the locking cap cover.
•
Lift up the cover.
•
Refer to figure 6 for the following procedures)
•
Remove the screw (3) which secures the knob (4) and then remove the knob.
•
Locate the pressure adjustment (by-pass) screws (5 and 6)
•
Opening pressure screw
(green wording = gate opening direction)
•
Closing pressure screw (red wording = gate closing direction
N O T E : F A A C recommends the maximum pressure to be set at 33lbs at the leading edge of the gate leaf.
WARNING: Do Not Exceed the UL regulations of 45lbs. At the leading edge of the gate leaf
Figure 6. Locking Cap
Assembly
Page 10
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
E
XPLODED
V
IEW
, L
OCKING
C
AP
I
NSTALLING THE
455 D C
ONTROL
P
ANEL
Locate the enclosure in the most convenient position possible, considering the movement of the gate.
Installing the control panel consists of the following general steps:
• Connecting the main power to the pre wired enclosure
• Connecting the activating device
• Connecting the operator(s)
• Checking the direction of the motor's rotation
• Set operating modes
The installer is responsible for grounding the gate and operator systems, for providing the main power breaker switch, and for making sure that the entire gate system meets all applicable electrical codes.
For the complete 455 D Control Panel Installation
Instructions, see pages 14—25 of this manual.
B
LEED THE
O
PERATOR
Air in the hydraulic fluid causes erratic performance in a hydraulic system, so you must rid the 400 Operator of that air to insure smooth operation.
In order to bleed the air out of the system, remove the vent screw and simply run the operator with the electronic control panel. The 400 will bleed itself.
3 701526 Torx (SS T-20 Security)
11 722795 Receiver
14 718359 Manual Release Extension
18 4185045 Locking Cap Assembly
QTY
1
1
3
1
1
1
1
1
1
1
1
1
2
1
3
1
1
1
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
E
XPLODED
V
IEW
, C
YLINDER
Page 11
1 7049005
2 N/A
3 4404065
4 7049005
5 4404085
6 4994655
7 7230295
8 N/A
10 4180285
11 7366025
12 7091015
13 4350105
14 4994625
15 N/A
16 N/A
18 7090815
19 N/A
DESCRIPTION QTY
4
(Inlet/Lock 5
1
Lock Valve (Bi-Metal)
4
2
1
4
4
20 7361335
21 4180415
22 4180415
23 4180415
Cylinder
1
1
1
2
1
25 N/A
26 4180195
27 4180415
28 4404095
1
4
1
2
O-Ring (Retract Tube 06’) 2
1
DESCRIPTION QTY
1
2
2
2
1
1
1
2
Valve 1
Page 12
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
E
XPLODED
V
IEW
, 400 CBAC
400 REAR FLANGE PARTS LIST
4 N/A
6 7109135 Strain Relief (Pig Tail)
QTY
1
1
1
2
1
1
1
1
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
E
XPLODED
V
IEW
, 400 CBAC
Page 13
400 P
ARTS
L
IST
1 2036 Galvanized (8MM)
2 7220015 Rear Mounting Bracket
3 7284005 Rear Mounting Plate
4 7182075 Short (Brass)
6 2037 Self
9 490325
10 N/A
Locking Cap Kit
12 2365
13 2366
14 N/A
18 N/A
20 N/A
22 2274
2
1
1
1
4
1
1
1
2
1
1
2
4
4
4
QTY
1
1
29 3204425
30 N/A
1
1
1
1
32 3060
33 2069
35 7220355
36 N/A
38
39
7019195
4170015
Pump 1.lt (Lobe Type)
Pump (4x28mm)
Washer
Front Mounting Bracket
Tie Rods (Protective Cover)
End Cap (Protective Cover)
42 2167+ Seal
43 6115 Lubrication Engineer Oil
44** 2707
45 7228015+ Aluminum Fork Kit
•
* 115VAC Motor Part Number Is 77000425
•
** 25µF Capacitor For Use With 115VAC Motor
Part Number Is 2705
1
2
2
1
1
1
1
2
QTY
1
1
3
1
1
1
1
1
Page 14
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
T
HE
455 D C
ONTROL
P
ANEL
G
ENERAL
D
ESCRIPTION
The FAAC 455 D control panel is used to operate the following models.
Swing gate operators:
400 412 415
750 402
422
610/615
760
Barrier gate operators:
The 455 D programming controls the following:
Operating logic: A, S, E, EP, B, and C logics available.
Reversing device behavior: Choose whether a triggered reversing device during closing immediately reverses gate movement or stops the gate and reverses gate movement when no longer triggered.
Torque or Pressure: Force adjustment for the
412 operator. Adjustable from 0 to 50.
Caution: For all hydraulic operators, the torque must be programmed to the maximum (50) setting.
Pause time between opening and closing: adjustable from 0 to 240 seconds.
O p e n i n g / C l o s i n g t i m e : a d j u s t a b l e from 0 to 120 seconds.
Leaf delay on closing: adjustable from 0 to 28 seconds.
The 455 D control panel should be installed in an enclosure that is conveniently located as close as possible to the gate operator. All electrical connections from the control panel to the operator must be made in a weatherproof junction box.
The 455 D control panel requires a single-phase power supply voltage (115 VAC [±10%] or 230 VAC
[+6 or -10%], 50–60 Hz). The power supply should be protected by a 15 amp dedicated circuit breaker (not provided).
The installer is responsible for grounding the operator system, for providing the main power breaker switch, and for making sure that the entire gate system meets all applicable electrical codes.
The installer should refer to the installation manual for a given operator for more information.
N
OTE
: An installation is U.L. compliant only when you install the FAAC operators according to the UL325 standards.
I
NSTALLING THE
455 D C
ONTROL
P
ANEL
Locate the control panel in the most convenient position possible, considering the movement of the gate.
Installing the control panel consists of the following general steps:
•
Connecting the main power to the control panel
• Connecting the activating device
•
Connecting the operator to the control panel
• Checking the direction of the motor's rotation
•
Connecting other devices to the control panel
• Set operating modes
C
ONNECT THE
M
AIN
P
OWER
S
UPPLY
WARNING!
Turn the main power off before you make any electrical connections or before programming.
Wire the main power supply to control panel terminals in block J3 (see Figures 9 and 11). The installer is responsible for insuring that a separate, grounded circuit protected by a circuit breaker is between the control panel and the main power supply. All wiring should conform to applicable electrical codes, and all wiring and fittings should be weatherproof and/or suitable for burial.
Connect the ground to the grounding terminal in block
J3 and connect the power wires to the terminals labeled
N (neutral) and L (line).
N
OTE
: For a 230V system, a neutral is not needed. Connect one 115V line to the L (Line) and a second 115V line to the N (Neutral).
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
C
ONNECT THE
O
PERATOR
(
S
)
TO THE
C
ONTROL
P
ANEL
WARNING!
Turn the main power off before you make any electrical connections or before programming.
C
AUTION
:
The operators are grounded only by the grounded circuit the installer provides.
U
SING A
J
UNCTION
B
OX
If an operator is more than 2 ft away from the control panel, you must use a junction box for connection.
Use a U. L. Listed cord grip where the operator cord enters the junction box.
Note: If you have a one-leaf gate design, the operator must be connected to Motor 1
(terminals 1,2, & 3)
To wire up motor 1, connect the white wire to terminal 1(on the J4 terminal strip), the black wire to
2, and the red wire to 3. Wire each leg of the capacitor
(supplied) to terminals 2 & 3.
Note: If you want to delay the closing of one gate leaf in a two-leaf gate design, be sure to connect its operator to Motor 1.
Page 15
In order to wire motor 2 in a bi-parting system, connect the white wire to terminal 4 (on the J4 terminal strip), the black wire to 5, the red wire to 6.
Wire each leg of the capacitor (supplied) to terminals
5 & 6.
C
HECK THE
M
OTOR
’
S
D
IRECTION OF
R
OTATION
WARNING! The pressure valves are not preset at the factory and may operate a gate leaf with enough force to endanger people and seriously damage the gate leaf itself. Refer to your operator’s installation manual to decrease the hydraulic pressures before checking the motor’s direction of rotation.
After you have connected the main power supply, and the operator(s) to the control panel, you need to check the direction of rotation for each operator motor in your gate design.
Note: To check a motor’s direction of rotation, you must have three closed circuits on terminal block. Install one circuit between terminals 11 and 16 (already installed by factory), another circuit between terminals “PHOTO OP/CL”, and another circuit between terminals “PHOTO CL”.
J3 terminal block for main power supply
Figure 9. The 455 D Control Panel
J4 terminal block for connecting the operator(s)
F2
K
1-455D115 = 115V
1-455D = 230V
+
-
F
J2
J1 terminal block for lowvoltage accessories
J2 quick connector port
F Function Push Button
V1-4
61C455D
— Programming Push
Button
M
F1
M
J3
N L
MAIN
1 2 3 4 5 6 7 8
COM OP CL
MOTOR 1
COM
OP
MOTOR 2
CL
LAMP
J5
J6
22 23 24 25
J4 J1
9
A
10 11 12 13 14 15 16 17 18 19
B NC
STOP
CL OP
FSW
-
+
+24 V
+
20 21
TX
FSW W. L.
LOCK
+ Programming Push
Button
FUSES
220
VAC
115
VAC
F1
Main Power
F2
Accessories
5 A
800 mA
10 A
800 mA
Page 16
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
N L
1 2 3 4 5 6 7 8
C OM OP
MOTOR 1
C L C OM OP
MOTOR 2
C L
LA MP
C 1 C 2
9 10 11 12 13 14 15 16 17 18 19
C L OP
FS W
+
24V
+ -
FS W
20 21
W .LIGHT
LOCK
22 23 24 25
115 V A C +/- 10% or
230 V A C +6/ -10%
50-60 Hz
M1 M2
24 vdc
3 W
OP E N OP E N
(1 of 2)
S TOP
Figure 10.
The terminal strip wiring of the 455 D with photobeams
Other safeties
E LE CTRIC LOCK
NOTE : In order to c om ply with UL 325, two s ets of FA A C photobeams m us t be ins talled. One s et s hould be 6 in. outs ide the c los ed gate(s ) and ac t as a c los ing rev ers ing dev ic e. A nother s et s hould be 6 in. bey ond the s wing of the gate(s ) and ac t as an opening rev ers ing dev ic e. The ins taller is res pons ible for determining the appropriate m ounting height.
You cannot check the motor’s direction of rotation without these circuits (jumpers) or the accessories.
When properly prepared for testing, the LEDS FSWOP,
STOP, and FSWCL should be illuminated (see figure 12 on page 17).
WARNING! Running the operator—even for testing purposes—without a connected reversing device is potentially dangerous. Do not place yourself within the path of the moving gate during your test.
Disengage the operator(s) with the Manual Release key (see operator installation manual), and open the gate by hand about halfway.
Next, engage the operator(s) with the Manual Release key so that you can check the rotation of the motor(s).
To activate the operator(s) momentarily short across terminals labeled “OPEN DEVICES”.
Turn on the main power and send an activating signal to the operator. The gate leaf (or leaves) should open.
If a gate leaf closes, then you need to turn off the main power and reverse the connection of the red and black wires on terminal block for the operator controlling that leaf. Then you need to recheck the rotation direction again.
After having completed your test of the motor’s direction of rotation, replace any test circuits you installed (between terminals between “PHOTO CL”, and between “PHOTO OP/CL”) with the proper reversing devices. The instructions for installing such accessories follow.
1
2
1
2
3
4
5
FS W OP
FS W CL
1
2
1
2
3
4
5
C
ONNECT
O
THER
D
EVICES
WARNING! Turn the main power off before you make any electrical connections.
P
OWER
S
UPPLY FOR
A
CCESSORIES
: You can access a 24
VDC output for supplying power to accessories through terminals (+) and 14 (-) on the pre-wired terminal block. In most cases, this source can be used to power 24 VDC accessories.
N
OTE
: The 455 D control panel allows a maximum accessory load of 800 mA.
R
EVERSING
D
EVICES
: Reversing devices include photocells, inductive loops, and so forth. All of the reversing devices should have contacts of the normally closed (N.C.) type. Where you connect a device depends on whether you want the device to operate during opening or during closing.
N
OTE
: UL does not recognize the FAAC system with loop detectors or safety edges. FAAC photobeams must be used to comply with UL
325.
To wire photobeams, refer to page 19 (see “PHOTO
OP/CL” for opening photobeams, and “PHOTO C/L” for closing photobeams). Photobeams must be connected as shown. See page 19 for the wiring of inductive loops. If using more than one reversing device, they must be wired in series.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
(a) To the U. L. Listed gate operator
(b)
Page 17
U.L. Listed Control Panel Enclosure
U.L. Listed cord grip
Junction box
Figure 11.
Wiring detail (a) inside the junction box and
(b) from the junction box or operator to the high-voltage terminal strip on the 455 D control panel
To the U.L. Listed control panel
Legend
White
Red
Black
Yellow/
Green
Conduit to U.L. Listed control panel enclosure according to N.E.C.
455 MPS Control Panel
J3 J4
High-voltage terminal strip
J1
COM OP CL COM OP CL
Ground
A
CTIVATING
D
EVICES AND
R
ADIO
R
ECEIVER
: The activating devices and radio receiver for your gate must have normally open (N.O.) contacts. Connect such devices to terminals “OPEN DEVICES”.
N
OTE
: The FAAC radio receiver plugs into the 5 prongs labeled J2 on the 455D (Quick connect port).
D
ECODER
C
ARD
: If you are installing the Digicard magnetic card reader, or the Digikey keyboard, use the quick-fit connector J2 for the DS decoder card (see
Figure 1).
N
OTE
: If your using both a receiver and decoder, hard wire the decoder and plug in the receiver.
O
PEN
/H
OLD
O
PEN
D
EVICE
: To open and hold open the gate, simply maintain a contact across terminals “OPEN
DEVICES”. (“A” Mode only)
S
TOP
B
UTTON
: The stop button you install must have normally closed (N.C.) contacts. Multiple stop buttons must be wired in series. Connect your stop device between terminals 11 and 16. (This jumper is already provided form factory.
N
OTE
: The 455 will not operate the motors without a closed circuit between 11 & 16.
The LED Indicators: The nine light emitting diodes
(LEDs) on the control panel can be used to check for the proper function of the devices attached to the panel. The LED lights are on whenever the contacts are closed across each of the respective terminals.
OP_A and OP_B (Partial Opening) should illuminate only when an activating signal is sent for 2 and 1 gate leaves, respectively. STOP should be illuminated except when the stop button is pressed. FSWOP and FSWCL should be
LED
OP_A
OP_B
Stop
FSW
Open
FSW
Close
FCA1
FCC1
FCA 2
FCC 2
O P _ A
S T O P
O P _ B
Cord grip or conduit from
U.L. Listed gate operator(s)
Command Given
Command Given
No Command
Opening reversing devices clear
Closing reversing devices clear
Flashes when gate coder is in use.
Flashes when gate coder is in use.
F S W O P
F S W C L
On
F C A 1
F C A 2
This display shows the meaning of each LED.
No Command
No Command
Command Given
Reversing device triggered
Reversing device triggered
Operator 1
Operator 2
F C C 1
F C C 2
Op.1
OP_A
STOP
OP_B
Op.2
Off
FSWOP
FSWCL
FCA1
FCA2
FCC1
FCC2
This display shows the normal status of the control panel.
Figure 12. The 455 D display.
Page 18
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
opening and closing, respectively, are triggered. Use the LEDs and the next table to determine if the accessory devices you have installed are operating properly.
Electric Locks: An electric lock can be wired to the
455 D in terminals 18 and 21 (12Vac pulsed provided). If a reversing stroke is needed to allow the electric lock to release, this must be done in advanced programming. A Magnetic Lock Diagram can be found on page 23
W
ARNING
L
IGHT
: Connect a warning light to terminals 18 and 20 in the group labeled W.LIGHT in terminal block J1 and J5. The terminals provide an output voltage of 24 VDC, maximum power 3
Watts. This output voltage will power most 24 VDC warning lights.
N
OTE
: The behavior of the warning light varies according to the logic you have set.
L
OGICS
A, S, E, EP,
AND
B: The warning light is on steadily during opening and the pause phase. During closing, the light flashes.
L
OGIC
C: The warning light is on steadily during opening and flashes during closing.
S
ET
O
THER
O
PERATING
C
ONTROLS
WARNING! Turn the main power off before you make any electrical connections.
You need to program the control panel for your gate's operation. The 455 D Control Panel has on board programming that controls a wide range of functions.
O
PERATING
L
OGICS
N
OTE
: The 455 D Control Panel provides inputs for opening reversing devices and closing reversing devices. FAAC strongly recommends the use of reversing devices, such as photocells or other non-contact sensors.
• A (automatic): The gate opens on command and automatically closes after a pause phase. A second command while opening is ignored; a second command during the pause phase interrupts the pause time; a second command during closing reopens the gate. A maintained open command will hold the gate open.
• S (security): The security mode is like A logic except that a second command during opening immediately closes the gate. A maintained open command will not hold the gate open.
• E (semi-automatic): This mode requires a command to open and a command to close.
A second command during opening stops the gate. A second command during closing reopens the gate.
• EP (semi-automatic, step by step): This mode requires a command to open and a command to close. A second command during opening or closing causes the gate to stop. A third command then reverses the previous motion of the gate.
• B (manned, pulsed): This mode is designed for guard station use and requires a threebutton switch (pulsed) to open, close, and stop the gate.
• C (manned and constant): This mode requires constant pressure switches. One to open and one to close. No pressure on a switch stops the gate.
The three programming push buttons allow the programming of the torque (or pressure), the pause time between opening and closing, and the leaf delay on closing.
WARNING! Turn the main power off before you make any electrical connections.
For all FAAC hydraulic operators using the 455 D control panel, the force must be set at its maximum setting of 50 in order to supply the correct voltage to the operator.
P
AUSE
T
IME
: The pause time between opening and closing can be adjusted from 0 seconds to 4 minutes.
Time is adjusted in one-second increments from 0—
59 seconds. When 60 seconds is reached, time is adjusted in 10 second increments up to 4 minutes. i.e. if display shows 2.5, it means 2 minutes and 50 seconds.
L
EAF
D
ELAY
: You may choose to delay one leaf on closing for overlapping gate leaves. Be sure the operator on the leaf for delayed closing is connected to Motor 1. On opening, the leaf connected to Motor 2 is delayed 2.5 sec.
N
OTE
: If an opening leaf delay is desired, it must be enabled in the Advance Programming.
However, if enabled, you cannot adjust this opening delay of the operator connected to
Motor 2.
The closing leaf-delay time is adjustable from 0 to 4 minutes.
N
OTE
: If the opening/closing time is set at less than the leaf delay time, the delayed leaf closes at the end of the closing time.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual Page 19
Figure 13. Pre-wired Enclosure with the 455 D Control Panel
Page 20
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
P
ROGRAMMING
To program the automated system, the
“Programming Mode” must be accessed.
Programming is split into two parts: BASIC and
ADVANCED.
B
ASIC
P
ROGRAMMING
To access BASIC PROGRAMMING, press the “F” key.
•
If you press it (and hold it down), the display shows the name of the first function.
•
If you release the key, the display shows the value of the function that can be modified with keys + and — .
•
If you press and hold down the “F” key again
(and hold it down), the display shows the name of the next function, etc.
•
When you reach the last function, press “F” to exit the program, and the display resumes showing the status of the inputs.
The table on the right shows the sequence of functions accessible in BASIC PROGRAMMING.
A
DVANCED
P
ROGRAMMING
To access ADVANCED PROGRAMMING, press the “F” key and, as you hold it down, press the “+” key:
•
If you release the “+”, the display indicates the name of the first function.
•
If you release the “F” key, too, the display shows the value of the function that can be modified with keys “+” and “—”.
•
If you press the “F” key (and hold it down), the display shows the name of the next function, and if you release it, the value that can be modified with keys “+” and “—”.
•
When you reach the last function, press the “F” key to exit the program, and the display resumes showing the status of the inputs.
The table on page 21 shows the sequence of functions accessible in ADVANCED PROGRAMMING
BASIC PROGRAMMING
Display Function
F
O
PERATING
L
OGICS
A = Automatic (Timer to Close)
E = Semi Automatic
S = Security
EP = (Semi-Automatic) Step by Step
B = Manned, Pulsed
C = Manned, constant
P
AUSE
T
IME
This is the time between open and closing and is adjustable from 0 to
4 min. This is only true in “A”
Mode. (see pause time description)
F
ORCE
/T
ORQUE
M
OTOR
1
This adjusts the force / torque that motor 1 is applying to the gate leaf. Setting is 0 to 50.*
F
ORCE
/T
ORQUE
M
OTOR
2
This adjusts the force / torque that motor 2 is applying to the gate leaf. Setting is 0 to 50.*
C
LOSING
L
EAF
D
ELAY
Delays the closing of operator wired into motor one outputs. Adjustable from 0 to 4 minutes
(Same as pause time)
M
OTOR
R
UN
T
IME
This enables where you choose from “simple” learning or
“complete” learning of the motor run time. See “complete learning” paragraph for complete details.
+
~ 1 s.
Complete Learning
+
> 3 s.
Default
PROGRAM BUTTONS
+ -
F
E
XIT
P
ROGRAMMING
Exit from programming and return to display of inputs status.
LEFT MIDDLE RIGHT
the maximum setting of 50.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
ADVANCED PROGRAMMING I
NDICATOR
-L
ICHT
:
If 0 is selected, the output functions as a standard indicator-light
(lite at opening and pause, flashing
Display Function Default
M
T
AXIMUM
HRUST
T
ORQUE AT
I
NITIAL
: The motors oper-
(ignoring the torque setate at maximum torque ting) at start of movement.
Useful for heavy leaves.
at closing, and off when gate closed). Time can be adjusted from 0 to 59s in 1s increments, and from 1.0 to 4.1 min. in 10s steps.
0 = Standard Indicator-Light
From 1 to 4.1 = Timed Output
Y = Enable
No = Disabled
L
AST
S
TROKE AT
C
LOSING
:
The motors are activated at full speed for 1s to facilitate locking of the electric lock.
Y = Enable
No = Disabled
C
LOSING
P
HOTOCELLS REVERSE AT RE-
LEASE
: Enable this function if you want the closing photocells to stop the gate and reverse it after the beam is cleared. Default setting is immediate reverse.
Y = Enable
No = Disabled
R
EVERSING
S
TROKE
:
Before opening, while the gate is closed, the motors thrust to close for 2 s thus facilitating release of the electric lock.
Y = Enable
No = Disabled
A.D.M.A.P. F
UNCTION
:
If this function is enabled, the safety devices to comply with
French standard NFP 25/362.
Y = Enable
No = Disabled
L
EAF
2 O
PENING
D
ELAY
(2
S
):
Enables delayed start of leaf 2, avoiding interference between leaves.
Y = Enable
F
AIL
S
AFE
:
If this function is activated, it enables a function test of the photocells before any gate movement.
Y = Enable
No = Disabled
P
RE
F
LASHING
(5
S
):
5s before start of movement.
Y = Enable
No = Disabled
E
LECTRIC
L
OCK ON
L
EAF
2:
For using the electric lock on leaf 2 instead of on leaf 1.
Y = Enable
No = Disabled
A
SSISTANCE
R
EQUEST
(
COMBINED WITH
NEXT FUNCTION
): If activated, at the end of countdown (settable with the next function, i.e. “Cycle programming”) it effects 8s of pre-flashing at every Open pulse (job request).
Can be useful for setting scheduled maintenance jobs.
Y = Enable
No = Disabled
C
YCLE
P
ROGRAMMING
:
For setting count down of system operation cycles. Settable (in thousands) from 0 to 99 thousand cycles. The displayed value is updated as cycles proceed. This function can be used to check use of the board or to exploit the
“Assistance Request” function.
E
XTRA
W
ORK
T
IME
:
When operating, if reversing occurs, and if the leaf does not reach its end contact point, you can activate this function to increase work time.
Y = A
CTIVE
N
O
= D
ISABLED
E
XIT
P
ROGRAMMING
:
Exit from programming.
Page 21
Page 22
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
L
EARNING OF
O
PERATING
T
IMES
WARNING: During the learning procedure, the safety devices are disabled! Therefore, any and all traffic must be avoided in the path of the gate leaf(s).
NOTE: Programming must start with the gate(s) in the closed position.
Opening/closing time is established by the learning procedure which varies slightly according to whether you are or are not using Gatecoders.
L
EARNING OF
N
ORMAL
T
IMES
Normal learning (i.e. without Gatecoders) can be done in two different ways:
S
IMPLE
L
EARNING
(
WITHOUT
S
LOW
D
OWN
)
Close the gates, enter “B
ASIC
P
ROGRAMMING
”, select the
TIME LEARNING function and press the + push-button for 1 second the display begins flashing and the leaves begin the opening movement.
Wait for the leaves to reach the opening positive stop and then supply an OPEN command after the desired motor run time has been reached (by push-button or radio control) to stop the movement: the leaves stop and the display stops flashing. Press the “F’ Button one more time. One more command given will close the gate.
The procedure has ended and the gate is ready to operate.
C
OMPLETE
L
EARNING
(
WITH
S
LOW
D
OWN
)
N
OTES
:
•
If you do not wish to slow the gate operator(s) down, wait for the gate to reach its positive stop and supply two (2) consecutive open commands (within 1 second).
•
If only one gate operator (1) is used, you must go through the entire programming procedure, as if you were programming for two gate operators (2). When the operator has finished opening, supply 5 open commands until the gate operator begins to close, and then resume normal operations.
Close the gates, enter “B
ASIC
P
ROGRAMMING
”, select the
TIME LEARNING function and press the + push-button for more than 3 seconds: the display begins flashing and leaf 1 begins opening. The following functions can be commanded by the OPEN A (by push-button wired to terminals “OPEN DEVICES”, or radio control):
•
When gate operator (1) reaches the position that you want it to slow down, an open command must be given to start the slow down phase.
•
When gate operator (1) reaches the positive stop and the desired motor run time has been reached, an open command must be given to shut the motor off. At this point gate operator (2) will automatically start to open.
•
When gate operator (2) reaches the position that you want it to slow down, an open command must be given to start the slow down phase.
•
When gate operator (2) reaches the positive stop and the desired motor run time has been reached, an open command must be given to shut the motor off. At this point gate operator (2) will automatically start to close.
•
When gate operator (2) reaches the position that you want it to slow down, an open command must be given to start the slow down phase.
•
When gate operator (2) reaches the positive stop and the desired motor run time has been reached, an open command must be given to shut the motor off. At this point gate operator (1) will automatically start to close.
•
When gate operator (1) reaches the position that you want it to slow down, an open command must be given to start the slow down phase.
•
When gate operator (1) reaches the positive stop and the desired motor run time has been reached, an open command must be given to shut the motor off.
The display stops flashing and the gate is ready for normal operation.
L
EARNING
T
IMES WITH
G
ATECODER
Learning with the Gatecoder can be done in two different ways:
S
IMPLE
L
EARNING
Close the gates, enter “Basic Programming”, select the
TIME LEARNING function and press the + push-button for 1 second: the display begins flashing and the leaves begin the opening movement.
The movement stops automatically when the opening positive stop is reached and the display stops
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Page 23
flashing.
The procedure has ended and the gate is ready to operate, using default slow down automatically set by the control panel.
C
OMPLETE
L
EARNING
N
OTES
:
•
If only one gate operator (1) is used, you must go through the entire programming procedure, as if you were programming a gate operator (2). When the gate operator
(1) has finished opening, supply 4 open commands until the gate operator begins to close, and then resume normal operations.
Close the gates, enter “B
ASIC
P
ROGRAMMING
”, select the TIME LEARNING function and press the + pushbutton for more than 3 seconds: the display begins flashing and leaf 1 begins opening movement. The following functions can be commanded by the OPEN
A command (by radio control or key push-button):
•
When gate operator (1) reaches the position that you want it to slow down, an open command must be given to start the slow down phase. When the gate operator reaches its positive stop, the operator will automatically shut off.
•
An open command must be given to start opening gate operator (2).
•
When gate operator (2) reaches the position that you want it to slow down, an open command must be given to start the slow down phase. When the gate operator reaches its positive stop, the operator will automatically shut off.
•
An open command must be given to start closing gate operator (2).
•
When gate operator (2) reaches the position that you want it to slow down, an open command must be given to start the slow down phase. When the gate operator reaches its positive stop, the operator will automatically shut off.
•
An open command must be given to start closing gate operator (1).
•
When gate operator (1) reaches the position that you want it to slow down, an open command must be given to start the slow down phase. When the gate operator reaches its positive stop, the operator will automatically shut off.
The display stops flashing and the gate is ready for normal operation.
N
OTES
:
•
The open command to slow down the gate should be given before the gate reaches the positive stop to prevent the gate from hitting the stop at full speed. The positive stop could be mistaken for an obstacle and then upon hitting it, the gate(s) would automatically reverse on contact.
A
UTOMATED
S
YSTEM
T
EST
When you have finished programming, check if the system is operating correctly.
Most important of all, check that the force is adequately adjusted and that the safety devices are operating correctly.
If pressure adjustments on hydraulic operators are not set before programming. It may need to be reprogrammed for desired results.
Magnetic Lock
17
14
18
21
+
-
Lock
12 vac
Relay
N.C.
N.O.
COM
Magnetic Lock Diagram
Page 24
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Gate Status
Closed
Opening
Opened
Closing
Open A
A (Automatic) Logic (455 D)
Open B Stop Opening
Reversing
Device(s)
Opens both leaves and closes them after pause time
Opens single leaf connected to Motor
1 and closes it after pause time
No effect No effect
No effect
Interrupts the pause time
No effect
Interrupts the
pause time
Stops
Stops
Closing
Reversing
Device(s)
No effect
Stops; gate closes when reversing device no longer triggered
No effect
No effect
Gate remains open until reversing devices no longer triggered
Warning
Light
Off
On
On
Opens both leaves Opens leaf Stops No effect
Depends on DIP switch 4
Flashes
Stopped Closes the leaves Closes the leaf
No effect
(opening is inhibited)
No effect
Gate Status
Closed
Opening
Open A
S (Security) Logic (455 D)
Open B Stop Opening
Reversing
Device(s)
Opens both leaves and closes them after pause time
Opens single leaf connected to Motor
1 and closes it after pause time
No effect No effect
Closes both leaves Closes leaf Stops
Stops; gate closes when reversing device no longer triggered
No effect
(opening is inhibited)
Closing
Reversing
Device(s)
No effect
No effect
Opened
Closing
Closes both leaves
Opens both leave
Closes leaf
Opens leaf
Stops
Stops
No effect
No effect
Gate remains open until reversing devices no longer triggered
Depends on DIP switch 4
Stopped Closes the leaves Closes the leaf
No effect
(opening is inhibited)
No effect
No effect (opening is inhibited)
On
Warning
Light
Off
On
On
Flashes
On
Gate Status
Closed
Opening
Open A
Opens 1 or both leaves
No effect
B (Manned, Pulsed) Logic (455 D)
Open B
No effect
Stop
No effect
Opening
Reversing
Device(s)
No effect
Stops No effect
Closing
Reversing
Device(s)
No effect
Stops
Warning
Light
Off
On
Opened
Closing
Stopped
No effect
No effect
Opens 1 or both leaves
No effect
Closes 1 or both leaves
No effect
Closes 1 or both leaves
No effect
Stops
No effect
No effect
Stops
No effect
No effect
No effect
No effect
On
Flashes
On
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Gate Status Open A
E (Semi-automatic) Logic (455 D)
Open B Stop Opening
Reversing
Device(s)
Closed Opens both leaves
Opens single leaf connected to
Motor 1
No effect No effect
Opening
Opened
Closing
Stops
Closes both leaves
Closes both leaves
Stops
Closes leaf
Closes leaf
Stops
Stops
Stops
Closing
Reversing
Device(s)
No effect
Stops; gate closes when reversing device no longer triggered
No effect
No effect
No effect
(opening is inhibited)
No effect
(opening is inhibited)
Depends on DIP switch 4
Page 25
Warning
Light
Off
On
On
Flashes
Stopped Closes the leaves Closes the leaf
No effect
(opening is
inhibited)
No effect
No effect opening is inhibited)
On
Gate Status
Closed
Opening
Opened
Closing
Stopped
EP (Semi-automatic, Step by Step) Logic (455 D)
Open A Open B
Opens both leaves Opens single leaf
Stops connected to
Motor 1
Stops
Stop
No effect
(opening is inhibited)
Stops
Opening
Reversing
Device(s)
No effect
(opening is inhibited)
Stops; gate closes when reversing device no longer triggered
Closing
Reversing
Device(s)
No effect (opening is inhibited)
No effect
Closes both leaves
Stops
Gate leaves reverse direction
Closes leaf
Stops
Gate leaf reverses direction
Stops
Stops
No effect
(opening is inhibited)
No effect
No effect
(opening is inhibited)
No effect
(opening is inhibited)
No effect (opening is inhibited)
Depends on DIP switch 4
No effect
(opening is inhibited)
Warning
Light
Off
On
On
Flashes
On
Gate Status
Closed
Opening
Opened
Closing
Stopped
Open A
Opens 1 or both leaves
No effect
No effect
No effect
Opens 1 or both leaves
C (Manned and Constant) Logic (455 D)
Open B
No effect
Stop
No effect
Opening
Reversing
Device(s)
No effect
No effect
Closes 1 or both leaves
No effect
Closes 1 or both leaves
Stops
No effect
Stops
No effect
No effect
No effect
Stops
No effect
Closing
Reversing
Devices(s)
No effect
Stops
No effect
No effect
No effect
Warning
Light
Off
On
On
Flashes
On
Page 26
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
M
AINTENANCE
T
HE
400 O
PERATOR
The FAAC recommended maintenance schedule varies according to the frequency of use of the operators, whether lightly used operators (once or twice an hour) or heavily used operators (many cycles per hour).
Operators used in a humid/ salt air climate should follow the heavy duty use schedule.
Check the oil.
To check the oil level correctly, remove the locking cap from the operator. The operator should be at least half full.
Note: You will not be able to see the oil level.
Use something flexible (i.e. A piece of stranded wire) to act as a dipstick.
If the operator is too full, it will bleed oil out the vent hole.
Light duty use: check once per year
Heavy duty use: check every 6 mo
Change the oil.
Changing the oil requires removing the operator from its installed position. Remove the locking cap and drain the oil out of the hole under the cap. Refill the operator with the proper new oil (see page 4).
Light duty use: change every 4 yr
Heavy duty use: change every 2 yr
Check the pressure settings.
Light duty use: check once per year
Heavy duty use: check every 6 mo
T
HE
455 D C
ONTROL
P
ANEL
Keep the control panel free from spider webs, insects, etc.
Otherwise, the control panel requires no maintenance.
S
AFETY IN
G
ATE
D
ESIGN
•
A gate is a potential traffic hazard, so it is important that you locate the gate far enough away from the road to eliminate the potential of traffic getting backed up. This distance is affected by the size of the gate, how often it is used, and how fast the gate operates.
•
Pedestrians should not use a vehicular gate system.
Prevent such inappropriate use by installing separate gates for pedestrians.
•
The operating controls for an automatic gate must be secured to prevent the unauthorized use of those controls.
•
The operator you choose to install on your gate must be designed for the type and size of your gate and for the frequency with which you use the operator.
•
The controls for an automatic gate should be located far enough from the gate so that a user cannot accidentally touch the gate when operating the controls.
•
Your gate must be properly installed and must work freely in both directions before the automatic operator is installed.
•
Exposed, reachable pinch points on a gate are potentially hazardous and must be eliminated or guarded.
•
An automatic operator should be installed on the inside of the property/fence line. Do not install the operator on the public side of the property/fence line.
•
It is extremely unsafe to compensate for a damaged gate by over tightening a clutch or increasing hydraulic pressure.
•
Outward swinging gates with automatic operators should not open into a public area.
•
An automatic gate operator should not be installed on a gate if people can reach or extend their arms or legs through the gate. Such gates should be guarded or screened to prevent such access.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
Page 27
T
ROUBLESHOOTING
WARNING! Before you do any work on the control panel, be sure to turn off the main power.
NOTE: Any control panel specific information in the following applies to the 455 D control panel only.
P
ROBLEM
: T
HE GATE DOES NOT RESPOND TO
AN ACTIVATING SIGNAL
.
S
OLUTION
:
You should have at least one operator wired to terminals 1,2 and 3.
Be sure that you have the motor start capacitors wired in terminals 2 and 3, 5 and 6 with the directional leads.
Be sure that the torque/force setting is at the maximum setting of 50 in programming.
Verify that the LEDs FSWOP, FSWCL, and the STOP are illuminated. If they are not illuminated, be sure that you have closed circuits in the stop and reversing inputs.
Verify that your activating device works properly. OP_A should illuminate when you signal the gate to open. If
OP_A does not illuminate when you signal the gate, then the problem may be in your activating device. Short across terminals 9 and 14. If the short causes the gate to open, then the problem is in the activating device.
Repair or replace the device.
P
ROBLEM
: T
HE GATE DOESN
'
T OPEN
(
OR CLOSE
)
THOUGH THE MOTORS ARE RUNNING
.
S
OLUTION
:
Make sure that the motor is running in the right direction, and make sure the Manual Release mechanism has fully engaged the hydraulic system.
Increase the bypass pressure in small 1/4 turn increments to see if the hydraulic system needs more pressure.
P
ROBLEM
: T
HE GATE OPENS BUT DOES NOT
CLOSE
.
S
OLUTION
:
Make sure you have selected the desired operating mode.
Verify that the reversing devices are working properly.
FSWOP and FSWCL should be illuminated except when a reversing device is triggered. If either does not illuminate, then one of your reversing devices is preventing the gate from responding to your signal.
Check your reversing devices.
If no reversing devices are installed, make sure a circuit is installed between appropriate terminals.
P
ROBLEM
: T
HE GATE DOES NOT FULLY OPEN
(
OR CLOSE
).
S
OLUTION
:
Increase the bypass pressure(s) to see if the hydraulic system needs more pressure.
Check the operator's open/ close time selection. You should set a time that is just longer than the rated speed of your model of operator. For example, because the 400 CBAC has a rated opening time of 17 sec, you should set the time at 20 or 25 seconds.
Check to see that there are no obstructions in the path of the gate or that the hinges are not binding.
P
ROBLEM
: T
HE OPERATOR DOESN
'
T WORK
SMOOTHLY AND THE GATE JERKS AS IT OPENS
AND CLOSES
.
S
OLUTION
:
Check the oil level in the operator.
Make sure the Manual Release mechanism has fully engaged the hydraulic operation of the operator.
Bleed the air from the hydraulic system. (See page 11).
Make sure that a flexible gate leaf is not the problem. If the gate leaf flexes, then stiffen the gate or use a slower operator.
P
ROBLEM
: T
HE GATE DRIFTS OPEN OR CLOSE
WHEN THE MOTOR IS NOT RUNNING
.
S
OLUTION
:
Remove the manual release valve, located next to the pressure adjustment screws, with a 6mm hex key. Be sure that the white ring and the o’ring are not damaged.
If not damaged, there may be internal damage and a seal kit will be needed to rebuild the unit.
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
L
IMITED
W
ARRANTY
Page 28
To the original purchaser only: FAAC International,
Inc., warrants, for twenty-four (24) months from the date of invoice, the gate operator systems and other related systems and equipment manufactured by FAAC
S.p.A. and distributed by FAAC International, Inc., to be free from defects in material and workmanship under normal use and service for which it was intended
provided it has been properly installed and operated.
FAAC International, Inc.'s obligations under this warranty shall be limited to the repair or exchange of any part of parts manufactured by FAAC S.p.A. and distributed by FAAC International, Inc. Defective products must be returned to FAAC International, Inc., freight prepaid by purchaser, within the warranty period. Items returned will be repaired or replaced, at
FAAC International, Inc.'s option, upon an examination of the product by FAAC International, Inc., which discloses, to the satisfaction of FAAC International, Inc., that the item is defective. FAAC International, Inc. will return the warranted item freight prepaid. The products manufactured by FAAC S.p.A. and distributed by FAAC
International, Inc., are not warranted to meet the specific requirements, if any, of safety codes of any particular state, municipality, or other jurisdiction, and neither FAAC S.p.A. or FAAC International, Inc., assume any risk or liability whatsoever resulting from the use thereof, whether used singly or in combination with other machines or apparatus.
Any products and parts not manufactured by FAAC
S.p.A. and distributed by FAAC International, Inc., will carry only the warranty, if any, of the manufacturer. This warranty shall not apply to any products or parts thereof which have been repaired or altered, without FAAC
International, Inc.'s written consent, outside of FAAC
International, Inc.'s workshop, or altered in any way so as, in the judgment of FAAC International, Inc., to affect adversely the stability or reliability of the product(s) or has been subject to misuse, negligence, or accident, or has not been operated in accordance with FAAC
International, Inc.'s or FAAC S.p.A.'s instructions or has been operated under conditions more severe than, or otherwise exceeding, those set forth in the specifications for such product(s). Neither FAAC S.p.A. or FAAC International, Inc., shall be liable for any loss or damage whatsoever resulting, directly or indirectly, from the use or loss of use of the product(s). Without limiting the foregoing, this exclusion from liability embraces a purchaser's expenses for downtime or for making up downtime, damages for which the purchaser may be liable to other persons, damages to property, and injury to or death of any persons. Neither FAAC
S.p.A. or FAAC International, Inc., assumes nor authorizes any person to assume for them any other liability in connection with the sale or use of the products of FAAC S.p.A. or FAAC International, Inc. The warranty hereinabove set forth shall not be deemed to cover maintenance parts, including, but not limited to, hydraulic oil, filters, or the like. No agreement to replace or repair shall constitute an admission by FAAC S.p.A. or
FAAC International, Inc., of any legal responsibility to effect such replacement, to make such repair, or otherwise. This limited warranty extends only to wholesale customers who buy directly through FAAC
International, Inc.'s normal distribution channels. FAAC
International, Inc., does not warrant its products to end consumers. Consumers must inquire from their selling dealer as to the nature and extent of that dealer's warranty, if any.
This warranty is expressly in lieu of all other warranties expressed or implied including the warranties of merchantability and fitness for use. This warranty shall not apply to products or any part thereof which have been subject to accident, negligence, alteration, abuse, or misuse or if damage was due to improper installation or use of improper power source, or if damage was caused by fire, flood, lightning, electrical power surge, explosion, wind storm, hail, aircraft or vehicles, vandalism, riot or civil commotion, or acts of God.
FAAC International, Inc.
303 Lexington Avenue
Cheyenne, WY 82007
Advertisement
Key features
- Automatic gate opener capability
- Supports up to 2000lb gate weight
- Up to 20 ft gate length support
- Wide range of operating modes
- Adjustable opening and closing times
- Reversing device support
- Easy installation and setup
- Multiple accessory options
- Durable and reliable