QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6400 - FOR A GATE UP TO 10 FEET, 300 Lbs. AND OPENING CLOCKWISE
Model 115 VAC 6400 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the 6400 Actuator
Arm and Control Box Mounting manual and the
115 VAC Control Box Wiring/Owner’s manual.
Foundation Box Position
Gate weight NOT on gate operator.
3”
Post
1 1/2” to Drain
2 3/4”
DoorKing Heavy-Duty Hinges P/N 1200-039
U-channel NOT welded to gate. The gate can move in the U-channel during operation.
U-channel welded to gate arm
Foundation
Box
Driveway
Important Note: Operator drive motor and limit sensors are setup at the factory to open gate counter-clockwise.
Coaxial Cable Antenna Ki
P/N 1514-073 (Sold separately t
115
VAC
box near the operator with appropriate hardware
(Not supplied).
)
Circuit board power must be ON to adjust limit sensors, LEDs will light.
Limit Plat e
Auto-Close Timer
D
1 23
Opens Clockwise - OFF
1 to 23 sec.
OFF
OFF
ON
Shadow Loop - ON
OFF
OFF
OFF
Relay for Dual Plug-In Shadow Loop - ON
Relay for Dual Plug-In Shadow Loop - OFF
OFF
OFF
SW 1
SW 2
H
C
DO NOT
cycle operator before limit sensors and DIP-switches have been adjusted, damage could occur to gate and operator.
Tip: Do not drill any extra holes in the control box
.
y.
Radio Receiver
Not included - Refer to a specific
Radio Receiver Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation. See reverse side for wiring.
F
I
Single Channel Exit
Plug-In Loop Detector
4
5
6
7
1
2
3
A
B
DO NOT connect the
Primary operator to this connection.
Connect Secondary operator ONLY.
H
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
115 VAC Control Box
KEY SWITCH BUTTON: Cycles operator when pressed.
RESET BUTTON: Resets circuit board.
Mounting Holes
G 9410
C
Relay must be set to N.O. for shadow loop.
NO
NC
B
D
To #11
To #8
G 9409
Dual Channel
Reverse and Shadow
Plug-In Loop Detector
Battery Plug 3 Amp/Hr Batteries
Gate fits into U-Channel
Good Drainage
Gate hinges and operator pivot point are plumb.
Important:
Foundation Box MUST be level
and flush with driveway!
Limit Sensors
Open Position
The limit sensor assemblies must be slid 90° to open gate clockwise from factory setting.
Open
Limit Position
Open
Gray - Open (3 LED)
Purple - Slow Down (4 LED)
White - Common for each.
Close Close
Limit Position
Yellow - Close (5 LED)
Brown - Slow Down (6 LED)
White - Common for each.
Circuit Board Settings
Typical Settings for Single Operator with Plug-In Loops
See reverse side.
Fabri cated U-Channel (N
Clos ed Position ot Supplied)
A AC Power Switch
4302
#8 - #11 Shadow Loop Output
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Loop
Jumper
Mounting
Hole
E
AC Power Condui
Gate
Arm
1 1/2” to Drain (Not Supplied)
Drain Pipe
Drain pipe MUST slope away from the foundation box.
Drain pipe can connect to an existing drain pipe or be routed to a good drainage area.
A deep hole filled with “good” gravel is an acceptable drainage source. Check local building codes for further information before installation.
t
3/4”
Sweeps e
Grease Filler Hol
Apply Grease
Loops Condui t
3”
Lim it Plate
Driv r e
Linking Arm te
Han dle e
Founda
Box tion
3”
3”
Unlock and pull release handle from either side of the gate to manually operate the gate.
Depth of the concre is determined by specific installation requirements, soil conditions and local building codes.
The drive motor must be unbolted and flipped 180° to open gate clockwise as shown.
Copyright 2013 DoorKing, Inc. All rights reserved.
Brown wire
Orange wire
I
Red wire
Yellow wire
Green wire
Green/Yellow wire
Not Used
1
2
3
4
5
6
7
8
SECONDARY
Coaxial Cable Antenna
(Not Supplied)
F
Cable
Conduit
SINGLE/PRIMARY
Actuator Cable
Circuit Board
Connection
G
Secondary operator motor wires
MUST be reversed from the primary operator when used.
Plug-In Loop Detectors
Not included - Refer to the Wiring/Owner’s manual and Loop Information Manual
(available from www.dkaccess.com
) for more information on loops and loop detectors.
Alarm Reset
Chassis
Ground
115 VAC Input Power Wire
Wire Size
14 AWG
Distance
Up to 200 ft
12 AWG Beyond 200 ft
1. Brown
2. Blue
3. Orange
4. Red
5. Yellow
6. Green
7. Green/Yellow
G
Loop Wires
Tip: Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation. Keep them in separate conduits.
Important Power Note: To turn-off ALL power to the operator, the AC power switch must be turned off AND the battery plug must be disconnected from the circuit board.
DANGER
HIGH VOLTAGE
115 VAC Connection
E White - Neutral
Black - 115 VAC Hot
Green - Ground
CONTROL BOX MUST BE
PROPERLY GROUNDED!!
Tip: It is recommended that a surge suppressor be installed on the high voltage power lines.
6400-066-E-1-13
QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6004 - DIP-SWITCH AND WIRING REFERENCE
Model 115 VAC 6400 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the
6400 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner’s manual.
Main Terminal
SW 1 DIP-Switches
Switch Function Setting Description
Opening Direction of PRIMARY Operator
Drive Motor Orientation Drive Motor Orientation
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 Closed Closed
SW 1
4
2
3
5
6
Note: Limit sensors must be slid 90° on limit plate to open clockwise.
Open
OFF setting.
Opens clockwise.
ON setting. Opens counter-clockwise.
Note: Limit sensors are factory set to open counter-clockwise.
Open
Opening
Direction of
SECONDARY
Operator
Same opening directions as illustrated above for the primary operator type.
• Switch 2 will be the OPPOSITE setting as switch 1.
Note: SW1, switch 7 MUST also be ON when using a secondary operator.
Exit Loop Port
Output
OFF Terminal #4 is output from plug-in exit loop detector installed in EXIT loop port.
Open Input ON (normal) Terminal #4 is normal open command.
Auto-Close
Timer
Reverse
Not Used
Overlapping
Gates
OFF
ON
OFF (normal)
ON
OFF
ON
Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds.
Terminal #8 is a standard Reverse input.
On setting is NOT used.
Both operators start at the same time.
Secondary operator opens 1-2 seconds before primary operator. Vice-versa when closing.
Single
Dual
Input Power
OFF
ON
OFF
Switch must be OFF for single operator.
Switch must be ON when (dual) operators are used.
Switch MUST be in the OFF position.
7
8
SW 2 DIP-Switches
Switch Function
SW 2
1 and 2
3
4
Relay
Operation
Maglock Used
No Maglock
Spare
Setting
1-OFF 2-OFF
1-OFF
1-ON
1-ON
2-ON
2-OFF
2-ON
ON
OFF
OFF
Note: After a DIP-switch setting is changed, press the reset button for new settings to take effect.
Description
Relay activates when gate is fully open.
Relay activates when gate is not closed.
Relay activates when gate is opening and open. Shadow loop setting if used.
Relay activates when gate is opening and closing.
1 second delay to disengage maglock.
Leave in the OFF position if a maglock is NOT used.
Leave in the OFF position.
Power
Relay
Relay Com
Power Com
3-Wire
RF Receiver
Do not power any control devices from the circuit board other than low voltage devices.
4-Wire
RF Receiver
115 VAC
Box
Three 115 VAC Convenience Outlets
Power safety and opening devices that require 115 VAC power.
Reversing input on
Terminal #8 functions ONLY while the gate is at the FULL OPEN position or during the CLOSING cycle. It
MUST NOT be used as an input for a secondary entrapment protection device during the OPENING gate cycle. Refer to
Secondary Entrapment Protection Wiring in the Wiring/Owner’s manual.
Magnetic Lock
Com
N.C.
SW 2
Switch 3 ON
Note: Circuit board provides
24 VDC to power maglock.
Contact rating is 1 amp maximum at 24 Volts.
Safety Opening Device
Com
(Dry contact)
N.O.
Connect optional control devices to the main terminal. Use 18 AWG wire for all low voltage wiring, maximum distance 3000 feet. Use a low voltage surge suppressor, (DoorKing P/N
1878-010) if low voltage wire runs exceed 1000 feet. All control device inputs to the terminal must be
NORMALLY OPEN.
Com
N.O.
Keypad
(Dry contact)
Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls.
Com
N.O.
Key Switch
(Dry contact)
SW 1
Switch 3
MUST be
ON.
Com
N.O.
Telephone Entry
Note: Must use a separate power source.