Highlights
2200VA / 2.2kVA / 1800W on-line double-conversion 2U rack / tower UPS
100/110/120/127V 50/60Hz output; High efficiency economy mode option
Interactive LCD with 9 selectable screens of UPS and site power data
Expandable runtime, Hot-swap batteries, 19 in / 48.3cm depth
USB, RS232 & EPO ports, support for SNMP/WEB card option
2 independently switched load banks
NEMA 5-20P input; 6 NEMA 5-15/20R & 1 L5-20R outlets
This product is ENERGY STAR qualified for its ability to save customers
money while helping to protect the environment
Description
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters,
computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by
continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation
powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains
battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS
operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in
optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232,
contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure
monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and
Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS
operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. LED/LCD display
panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD
configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Battery independent restart. Field-replaceable, hot-swappable
internal batteries and external battery packs.
Package Includes
SU2200RTXLCD2U UPS System
PowerAlert Software with USB, Serial & EPO cabling
4 post rackmount installation kit
Instruction manual
Features
Tripp Lite SU2200RTXLCD2U 2200VA / 2.2kVA / 1800W on-line, double-conversion 2U rack / tower UPS
Selectable 100/110/120/127V output (120V factory preset)
NEMA 5-20P input, 6 NEMA 5-15/20R and 1 L5-20R outlets
Two switched 3-outlet load banks support remote reboot or programmable load shedding options
Supports 2% output voltage regulation and zero transfer time in double conversion mode
Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
12 minutes runtime at 50% load (900W) and 4 minutes at 100% load (1800W) with internal batteries
BP48V24-2U (limit 1) or BP48V60RT3U (no limit) external battery packs available (some configurations require Tripp Lite External Battery
Configuration Software)
LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz,
Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, Kw/hr. consumption)
LCD interface also supports 16 screens of UPS configuration and setup options
4 post installation hardware included, Optional 2POSTRMKITHD enables 2 post rack installation, Optional 2-9USTAND enables tower
4 post installation hardware included, Optional 2POSTRMKITHD enables 2 post rack installation, Optional 2-9USTAND enables tower
placement
Single line TEL / Network surge suppression
Electronic bypass maintains utility output during a variety of UPS fault conditions
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries
are expired and require replacement
Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60
to 50Hz
USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
2200
Output kVA
capacity (kVA)
2.2
Output Watt
Capacity (watts)
1800
Output kW capacity
1.8
Output power
factor
0.82
Output Capacity
Details
ON LINE MODE: Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 1800
watts / 115V 1620 watts / 110V 1530 watts / 100V 1440 watts). FREQUENCY REGULATION / CONVERSION MODE:
Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts / 115V 1134
watts / 110V 1071 watts / 100V 1008 watts)
Crest Factor
3:1
Nominal Output
Voltage(s)
Supported
100V; 110V; 115V; 120V; 127V
Nominal Voltage
details
120V factory-default nominal voltage
Frequency
compatibility
50/60 Hz (auto-selectable); Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency
compatibility
details
ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output
matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds
+/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY
REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to
70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is
regulated to +/-0.05Hz.
Output voltage
regulation (line
mode)
+/- 2%
Output voltage
regulation
(Economy line
mode)
+/- 10%
Output voltage
regulation (Battery
mode)
+/- 3%
Built-in UPS
output receptacles
6 5-15/20R outlet(s); 1 L5-20R outlet(s)
Built-in
controllable
switched load
banks
Two switchable three-outlet 5-15/20R load banks
Output AC
waveform (AC
mode)
Pure Sine wave
Output AC
waveform (battery
mode)
Pure Sine wave
INPUT
Rated input
current (at
maximum load)
16A
Nominal Input
Voltage(s)
Supported
100V AC; 110V AC; 115V AC; 120V AC; 127V AC
Nominal input
voltage description
120V factory default
UPS input
connection type
5-20P
Input circuit
breaker
30A
UPS Input cord
length (ft.)
10
UPS Input cord
length (m)
3
Recommended
Electrical Service
20A 120V
BATTERY
Full load runtime
(minutes)
4 min. (1800w)
Half load runtime
(minutes)
12 min. (900w)
Expandable
battery runtime
Extended runtime supported via optional external battery packs
External battery
pack compatibility
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible)
Expandable
runtime description
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see
manual for details
DC system voltage
(VDC)
48
Battery recharge
rate (included
batteries)
Less than 3 hours recharge to 90%
Replacement
battery cartridge
(internal UPS
battery
replacement)
RBC94-2U
Battery Access
Front panel battery access
Battery
replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and
overvoltages
Overvoltage
correction
Corrects overvoltages to 150V (0-100% load)
Undervoltage
correction
Corrects undervoltages to 100V at full load (90V at 100V nominal)
Severe
undervoltage
correction
Corrects brownouts to 70V (70% load) & 55V (33% load)
LEDS ALARMS & SWITCHES
LED Indicators
7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco
mode operation, bypass mode operation and AC output status
Front panel LCD
display
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data,
plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
Alarms
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Alarm cancel
operation
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option
available
Switches
2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select
options enable LCD status viewing and configuration options
SURGE / NOISE SUPPRESSION
UPS AC
suppression joule
rating
570
UPS AC
suppression
response time
Instantaneous
UPS Dataline
suppression
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form
factors supported
with included
accessories
4 post 19 inch rackmount
Installation form
factors supported
with optional
accessories
2 post rackmount (2POSTRMKITWM); 2 post rackmount (2POSTRMKITHD); Wallmount (2POSTRMKITWM); Tower
(2-9USTAND)
Primary form factor
Rackmount
UPS / Power
Module
dimensions in
primary form
factor (height x
width x depth /
inches)
3.5 x 17.5 x 19
UPS / Power
Module
dimensions in
primary form
factor (height x
width x depth / cm)
8.9 x 44.4 x 48.3
Rack Height
2U
Secondary form
factor
Tower (requires 2-9USTAND)
UPS / Power
Module weight (lbs)
48.5
UPS / Power
Module weight (kg)
22
UPS Shipping
dimensions
(height x width x
depth / inches)
9.5 x 20 x 24
UPS Shipping
dimensions
(height x width x
depth / cm)
24.1 x 50.8 x 61
Shipping weight
(lbs)
61.5
Shipping weight
(kg)
27.9
Cooling method
Fan
UPS housing
material
Steel
ENVIRONMENTAL
Operating
Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage
Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr.
(full load)
683
AC economy mode
BTU / hr. (full load)
390
Battery mode BTU
/ hr. (full load)
838
AC economy mode
efficiency rating
(100% load)
94%
Operating
Elevation (ft.)
0-3000m / 0-10,000 ft.
Audible Noise
50 dBA at 1m front side
Operating
Elevation (m)
0-3000 m
COMMUNICATIONS
Communications
interface
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network
monitoring port
description
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure
communications
PowerAlert
software
Included
Communications
cable
USB and DB9 cabling included
WatchDog
compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode
Low voltage
transfer to battery
power (setpoint)
100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load
High voltage
transfer to battery
power (setpoint)
150
SPECIAL FEATURES
Cold Start (startup
in battery mode
during a power
failure)
Cold-start operation supported
High availability
UPS features
Automatic inverter bypass; Hot swappable batteries
Green & high
efficiency features
High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy
mode operation
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of
Hazardous Substances); ENERGY STAR Qualified
WARRANTY
Product Warranty
Period (Worldwide)
2-year limited warranty
Connected
Equipment
Insurance (U.S.,
Canada & Puerto
Rico)
$250,000 Ultimate Lifetime Insurance
Related Items
Optional Products
Related Model
Description
Qty.
2POSTRMKITHD
Enables 2-Post Rackmount Installation of 3U and Larger UPS, Transformer and Battery
Pack Components
1
2POSTRMKITWM
Enables 2-Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems
1
WEXT3-2200-3000
3-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 2200-3000VA
1
WEXT5-2200-3000
5-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 2200-3000VA or less
1
SNMPWEBCARD
For remote monitoring and control via SNMP, Web or Telnet
1
ENVIROSENSE
Monitors temperature, humidity and contact-closure inputs. (Requires UPS with
SNMPWEBCARD, monitored PDU or switched PDU.)
1
RELAYIOCARD
Programmable Relay I/O Card
1
MODBUSCARD
For remote monitoring and control via MODBUS protocol
1
BP48V24-2U
External Battery Pack for UPS System
1
BP48V60RT-3U
External Battery Pack and Cable. 3U, Expandable, Blue 2-Point Connector
1
PDUB20
Single-Phase Hot-Swap PDU, 20A 120V, 2U Horizontal Rackmount, NEMA 5-15R &
5-15/20R outlets, set of 2 NEMA 5-20P input plugs
1
PDUMH20NET
Single-Phase Switched PDU, 20A 120V, 1U Horizontal Rackmount, NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter
1
PDUMH20AT
Single-Phase Auto Transfer Switch / Metered PDU, 20A 120V, 1U Horizontal
Rackmount, 5-15/20R outlets, 2 L5-20P / 5-20P adapters
1
PDUMH20ATNET
Single-Phase Auto Transfer Switch / Switched PDU 20A 120V, 1U Horizontal
Rackmount, 5-15/20R outlets, 2 L5-20P / 5-20P inputs
1
PDU1220
Single-Phase Basic PDU, 20A 120V, 1U Horizontal Rackmount, NEMA 5-15/20R outlets,
NEMA 5-20P input plug
1
PDUMH20
Single-Phase Metered PDU, 20A 120V, 1U Horizontal Rackmount, NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter
1
PDUMNV20
Single-Phase Monitored PDU, 20A 120V, 0U Vertical Rackmount, NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter
1
PDUMV20
Single-Phase Metered PDU, 20A 120V, 0U Vertical Rackmount, NEMA 5-15/20R outlets,
NEMA L5-20P input with 5-20P adapter
1
PDUMNH20
Single-Phase Monitored PDU, 20A 120V, 1U Horizontal Rackmount, NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter
1
PDUMV20NET
Single-Phase Switched PDU, 20A 120V, 0U Vertical Rackmount, NEMA 5-15/20R
outlets, NEMA L5-20P input with 5-20P adapter
1
More information, including related products, owner's manuals, and additional technical specifications, can be found online at
www.tripplite.com/en/products/model.cfm?txtModelID=5069.
Copyright © 2013 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous
improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising