Product data sheet 3RH1122-1AP00 CONTACTOR RELAY, 2NO+2NC, AC 230 V,

Product data sheet 3RH1122-1AP00 CONTACTOR RELAY, 2NO+2NC, AC 230 V,
Product data sheet
3RH1122-1AP00
CONTACTOR RELAY, 2NO+2NC, AC 230 V,
50 HZ, SCREW CONNECTION, SIZE S00
General technical data:
product brand name
SIRIUS
Product designation
contactor relay
Size of the contactor
S00
Protection class IP / on the front
IP20
Degree of pollution
3
Insulation voltage / with degree of pollution 3 / rated value
V
690
Installation altitude / at a height over sea level / maximum
m
2,000
• during transport
°C
-55 … +80
• during storage
°C
-55 … +80
• during operating
°C
-25 … +60
Ambient temperature
Contact reliability
one incorrect switching operation of 100 million
switching operations (17 V, 1 mA)
Resistance against shock
10g / 5 ms and 5g / 10 ms
Impulse voltage resistance / rated value
kV
6
Reference code
• according to DIN EN 61346-2
K
• according to DIN 40719 extended according to IEC 204-2 /
according to IEC 750
K
• according to DIN EN 81346-2
K
3RH1122-1AP00
Page 1/ 5
07/11/2014
subject to modifications
© Copyright Siemens AG 2014
Mechanical operating cycles as operating time
• of the contactor / typical
30,000,000
• of the contactor with added auxiliary switch block / typical
10,000,000
• of the contactor with added electronics-compatible auxiliary
switch block / typical
5,000,000
Control circuit/ Control:
Voltage type / of control feed voltage
AC
Control supply voltage frequency
• 1 / rated value
Hz
50
• 2 / rated value
Hz
60
• at 50 Hz / at AC / rated value
V
230
• at 60 Hz / at AC / rated value
V
230
Control supply voltage
Operating range factor control supply voltage rated value / of
the magnet coil
• at 50 Hz
• for AC
0.8 … 1.1
• at 60 Hz
• for AC
0.85 … 1.1
Apparent pull-in power / of the solenoid / for AC
V·A
27
Apparent holding power / of the solenoid / for AC
V·A
4.6
Inductive power factor
• with the pull-in power of the coil
0.8
• with the pull-in power of the coil
0.27
Auxiliary circuit:
Product extension / auxiliary switch
Yes
Identification number and letter for switching elements
22 E
Contact reliability / of the auxiliary contacts
1 faulty switching per 100 million (17 V, 1 mA)
Number of NC contacts / for auxiliary contacts
2
• delayed switching
0
• instantaneous switching
2
• asynchronous switching
0
• lagging switching
0
Number of NO contacts / for auxiliary contacts
2
• instantaneous switching
2
• delayed switching
0
• asynchronous switching
0
• leading switching
0
Number of changeover contacts
3RH1122-1AP00
Page 2/ 5
07/11/2014
subject to modifications
© Copyright Siemens AG 2014
• for auxiliary contacts
0
• of the auxiliary contacts / instantaneous switching
0
Operating current
• at AC-12 / maximum
A
10
• at 230 V / rated value
A
6
• at 400 V / rated value
A
3
• at 500 V / rated value
A
2
• at 690 V / rated value
A
1
• at 24 V / rated value
A
10
• at 110 V / rated value
A
3
• at 220 V / rated value
A
1
• at 24 V / rated value
A
10
• at 110 V / rated value
A
1
• at 220 V / rated value
A
0.27
• at AC-15
Operating current / with 1 current path
• at DC-12
• at DC-13
Short-circuit:
Design of the fuse link / for short-circuit protection of the
auxiliary switch / required
fuse gL/gG: 10 A
Installation/ mounting/ dimensions:
mounting position
+/-180° rotation possible on vertical mounting surface;
can be tilted forward and backward by +/- 22.5° on
vertical mounting surface
Mounting type
screw and snap-on mounting
Width
mm
45
Height
mm
57.5
Depth
mm
72
Distance, to be maintained, to the ranks assembly / sidewards
mm
0
Connections/ terminals:
Design of the electrical connection / for auxiliary and control
current circuit
screw-type terminals
Type of the connectable conductor cross-section
• for auxiliary contacts
• solid
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
• finely stranded
• with conductor end processing
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
• for AWG conductors / for auxiliary contacts
3RH1122-1AP00
Page 3/ 5
2x (20 ... 16), 2x (18 ... 14), 1x 12
07/11/2014
subject to modifications
© Copyright Siemens AG 2014
Certificates/ approvals:
Verification of suitability
CSA / UL / CCC / GL / LRS / BV / DNV / RMRS /
RINA
General Product Approval
Functional Safety /
Safety of
Machinery
Declaration of
Conformity
Type Examination
Test Certificates
Special Test
Certificate
Type Test
Certificates/Test
Report
Shipping Approval
Shipping Approval
other
other
Environmental
Confirmations
Safety related data:
Proportion of dangerous failures
• with high demand rate / according to SN 31920
%
75
• with low demand rate / according to SN 31920
%
40
Protection against electrical shock
finger-safe
T1 value / for proof test interval or service life / according to IEC
61508
a
20
B10 value / with high demand rate
• according to SN 31920
1,000,000
• note
With 0.3 x Ie
Further information:
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/
Cax online generator
http://www.siemens.com/cax
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
http://support.automation.siemens.com/WW/view/en/3RH1122-1AP00/all
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RH1122-1AP00
3RH1122-1AP00
Page 4/ 5
07/11/2014
subject to modifications
© Copyright Siemens AG 2014
last change:
3RH1122-1AP00
Page 5/ 5
Jul 7, 2014
07/11/2014
subject to modifications
© Copyright Siemens AG 2014
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement