Omron E2A3 - Datasheet

Omron E2A3 - Datasheet

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Omron E2A3 - Datasheet | Manualzz

Long Distance Cylindrical Proximity Sensor

E2A3

Extra long distance for increased protection and sensing performance

• triple distance proximity sensors for flush mounting requirements.

• designed and tested for extra long life.

Ordering Information

DC 3-wire Models

Size Type

Sensing distance

Connection

Body material

Thread length

Output Operation mode: NO Operation mode: NC

M8 Shielded 3.0mm

Pre-wired

M12 connector

M8 connector

(3-pin)

Stainless steel

(See note.)

27 (40) mm

27 (44) mm

27 (40) mm

PNP

NPN

PNP

NPN

PNP

NPN

E2A3-S08KS03-WP-B1 2M E2A3-S08KS03-WP-B2 2M

E2A3-S08KS03-WP-C1 2M E2A3-S08KS03-WP-C2 2M

E2A3-S08KS03-M1-B1 E2A3-S08KS03-M1-B2

E2A3-S08KS03-M1-C1

E2A3-S08KS03-M5-B1

E2A3-S08KS03-M5-C1

E2A3-S08KS03-M1-C2

E2A3-S08KS03-M5-B2

E2A3-S08KS03-M5-C2

M12 Shielded 6.0mm

M18 Shielded 11.0mm

M30 Shielded 20.0mm

Pre-wired

M12 connector

Pre-wired

M12 connector

Pre-wired

M12 connector

Brass

Brass

Brass

34 (50) mm

34 (49) mm

39 (60) mm

39 (54) mm

44 (65) mm

44 (59) mm

PNP

NPN

PNP

NPN

PNP

NPN

PNP

NPN

PNP

NPN

PNP

NPN

E2A3-M12KS06-WP-B1 2M E2A3-M12KS06-WP-B2 2M

E2A3-M12KS06-WP-C1 2M E2A3-M12KS06-WP-C2 2M

E2A3-M12KS06-M1-B1

E2A3-M12KS06-M1-C1

E2A3-M18KS11-WP-B1 2M E2A3-M18KS11-WP-B2 2M

E2A3-M18KS11-WP-C1 2M E2A3-M18KS11-WP-C2 2M

E2A3-M18KS11-M1-B1

E2A3-M18KS11-M1-C1

E2A3-M30KS20-WP-B1 2M E2A3-M30KS20-WP-B2 2M

E2A3-M30KS20-M1-B1

E2A3-M30KS20-M1-C1

Note:Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS303 (AISI), 2346 (SS).

E2A3-M12KS06-M1-B2

E2A3-M12KS06-M1-C2

E2A3-M18KS11-M1-B2

E2A3-M18KS11-M1-C2

E2A3-M30KS20-WP-C1 2M E2A3-M30KS20-WP-C2 2M

E2A3-M30KS20-M1-B2

E2A3-M30KS20-M1-C2

.

E2A3

D-35

Connectivity

E2A3 Sensors are available with the following connectors and cable materials:

Pre-wired Models

Connector Models

Standard connectors: M12, M8 (3-pin) -M1, -M5

Standard cable lengths are 2 m and 5 m.

For other cable lengths, please contact your OMRON representative.

Standard cable material: PVC (4-mm dia.)

Model Number Legend

-WP

E2A

@-@@@@@-@-@@-@@

1 2 3 4 5 6 7 8 9 10 11 12

Example: E2A3-M12KS06-M1-B1 Triple distance, M12, standard barrel, shielded, Sn = 6 mm, M12 connector, PNP-NO

E2A3-S08KS03-WP-B1 2M Triple distance, M8 stainless steel, standard barrel, shielded, Sn = 3 mm, pre-wired PVC cable,

PNP-NO, cable length = 2 m

1. Basic name 8. Kind of connection

E2A

2. Sensing technology

Blank:

3:

Standard double distance

Triple distance

3. Housing shape and material

M: Cylindrical, metric threaded, brass

S: Cylindrical, metric threaded, stainless steel

4. Housing size

08:

12:

18:

30:

8 mm

12 mm

18 mm

30 mm

5. Barrel length

K: Standard length

L:

6. Shield

Long body

S:

N:

Shielded

Non-shielded

7. Sensing distance

Numeral: Sensing distance: e.g., 03 = 3 mm, 11 = 11 mm

WP:

M1:

Pre-wired, PVC, 4-mm dia.

M12 connector (4-pin) *

M5: M8 connector (3-pin)

9. Power source and output

B:

C:

DC, 3-wire, PNP open collector

DC, 3-wire, NPN open collector

10.Operation mode

1: Normally open (NO)

2: Normally closed (NC)

11.Specials (e.g., cable material, oscillating frequency)

12.Cable length

Blank: Connector Model

Numeral: Cable length

D-36 Inductive Sensors

Specifications

DC 3-wire Models

Size

Type

M8

Shielded

M12

Shielded

M18

Shielded

M30

Shielded

Item

Sensing distance

E2A3-S08KS03-@@-B@

E2A3-S08KS03-@@-C@

3 mm

± 10%

E2A3-M12KS06-@@-B@

E2A3-M12KS06-@@-C@

6 mm

± 10%

Setting distance

Ambient temp. of

−25 to 70°C

Ambient temp. of

−10 to 60°C

Differential travel

0 to 2.1 mm

0 to 2.4 mm

0 to 4.2 mm

0 to 4.8 mm

0 to 7.7 mm

0 to 8.8 mm

Target

20% max. of sensing distance

Ferrous metal (The sensing distance decreases with non-ferrous metal.)

Standard sensing object 9

× 9 × 1 mm

Response frequency (See note 1.) 700 Hz

18

× 18 × 1 mm

350 Hz

33

× 33 × 1 mm

250 Hz

Power supply voltage

(operating voltage range)

Current consumption

12 to 24 VDC. Ripple (p-p): 10% max.

(10 to 32 VDC)

10 mA max.

E2A3-M18KS11-@@-B@

E2A3-M18KS11-@@-C@

11 mm

± 10%

Output type

Control output

Indicator

-B models: PNP open collector

-C models: NPN open collector

Load current 200 mA max. (32 VDC max.)

Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)

Operation indicator (Yellow LED)

E2A3-M30KS20-@@-B@

E2A3-M30KS20-@@-C@

20 mm

± 10%

0 to 14 mm

0 to 16 mm

60

× 60 × 1 mm

80 Hz

Operation mode

Protection circuits

Ambient air temperature

Temperature influence

Ambient humidity

Voltage influence

Insulation resistance

Dielectric strength

Vibration resistance

-B1/-C1 models: NO

-B2/-C2 models: NC

For details, refer to the timing charts.

Power source circuit reverse polarity protection,

Surge suppressor, Shortcircuit protection

Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection

Operating:

−25°C to 70°C, Storage: −25°C to 70°C

±20% max. of sensing distance at 23°C within temperature range of −25°C to 70°C

−10% to +20% of sensing distance at 23°C within temperature range of −10°C to 60°C

Operating: 35% to 95%, Storage: 35% to 95%

±1% max. of sensing distance in rated voltage range ±15%

50 M

Ω min. (at 500 VDC) between current-carrying parts and case

1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Standards and listings

(See note 2.)

500 m/s 2 , 10 times each in X, Y, and Z directions

IP67 after IEC 60529

IP69K after DIN 40050

EMC after EN60947-5-2

1,000 m/s 2 , 10 times each in X, Y and Z directions

Connection method

-WP models: Pre-wired Models (4-mm dia. PVC cable with length of 2 m)

-M1 models: M12 4-pin Connector Models

-M5 models: M8 3-pin Connector Models

Pre-wired Models Approx. 65 g Approx. 85 g Approx. 160 g

Weight

(packed state)

Approx. 35 g Approx. 70 g

Approx. 280 g

Approx. 200 g

Material

Case

Sensing surface

Cable

Clamping nut

Stainless steel

PBT

PVC

Stainless steel

Brass-nickel plated

Brass-nickel plated

Note 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object length between sensing objects, and a set distance of half the sensing distance.

2. For USA and Canada: use class 2 circuit only.

E2A3

D-37

Engineering Data

Operating Range (Typical)

12

10

8

6

4

2

0

30

22

20

18

16

14

20

Y

X

E2A3-M30KS20

E2A3-M18KS11

E2A3-M12KS06

E2A3-S08KS03

10 0 10 20 30

Distance Y (mm)

Influence of Sensing Object Size and Materials

E2A3-S08KS03

3.5

@d

X t = 1 mm

3.0

Iron

E2A3-M12KS06

7

@d

X t = 1 mm

6

Iron

2.5

2.0

Stainless steel (SUS303)

1.5

1.0

Brass

Aluminum

Copper

0.5

0.0

Side length of sensing object d (mm)

E2A3-M30KS20

25

@d

X t = 1 mm

20

Iron

Stainless steel (SUS303)

15

3

2

5

4

1

0

Stainless steel (SUS303)

Brass

Aluminum

Copper

Side length of sensing object d (mm)

E2A3-M18KS11

12

@d t = 1 mm

X

10

8

6

4

2

Iron

Stainless steel (SUS303)

Brass

Aluminum

Copper

0

Side length of sensing object d (mm)

10

Brass

Aluminum

Copper

5

0

0 10

Side length of sensing object d (mm)

D-38 Inductive Sensors

Operation

DC 3-wire Models

PNP Output

Operation mode

NO

NC

Model

E2A3-@-@-B1

E2A3-@-@-B2

Non-sensing area

Timing chart

Sensing area

Proximity

Sensor

Sensing object

(%)

100 0

ON

OFF

Yellow indicator

ON

OFF

Control output

Non-sensing area

Sensing object

(%)

100

Sensing area

Proximity

Sensor

0

ON

OFF

Yellow indicator

ON

OFF

Control output

Output circuit

Brown

+V

Proximity

Sensor main circuits

(See note 1.)

Black

Load

Blue

0 V

Note 1: With M8 Size Models, there is no output reverse polarity protection diode.

M12 Connector

Pin Arrangement

(See note 2.)

M8 Connector

(3-pin)

Pin Arrangement

2

1

4

3

1

4

3

Note 2: Terminal 2 of the M12 connector is not used.

Brown

+V

Proximity

Sensor main circuits

(See note 1.)

Black

(M8 connector: )

Load

Blue

0 V

Note 1: With M8 Size Models, there is no output reverse polarity protection diode.

M12 Connector

Pin Arrangement

(See note 2.)

M8 Connector

(3-pin)

Pin Arrangement

4

1

1 3

2 4

3

Note 2: Terminal 4 of the M12 connector is not used.

E2A3

D-39

DC 3-wire Models

NPN Output

Operation mode

NO

NC

Model

E2A3-@-@-C1

E2A3-@-@-C2

Non-sensing area

Timing chart

Sensing area

Proximity

Sensor

Sensing object

(%) 100 0

ON

OFF

Yellow indicator

ON

OFF

Control output

Non-sensing area

Sensing object

(%) 100

Sensing area

Proximity

Sensor

0

ON

OFF

Yellow indicator

ON

OFF

Control output

Output circuit

Brown

+V

Proximity

Sensor main circuits

(See note 1.)

Black

Load

Blue

0 V

Note 1: With M8 Size Models, there is no output reverse polarity protection diode.

M12 Connector

Pin Arrangement

(See note 2.)

M8 Connector

(3-pin)

Pin Arrangement

1

4

3

2 4

1

3

Note 2: Terminal 2 of the M12 connector is not used.

Brown

+V

Proximity

Sensor main circuits

Load

(See note 1.)

Black

(M8 connector: )

Blue

0 V

Note 1: With M8 Size Models, there is no output reverse polarity protection diode.

M12 Connector

Pin Arrangement

(See note 2.)

M8 Connector

(3-pin)

Pin Arrangement

4

1

1 3

2 4

3

Note 2: Terminal 4 of the M12 connector is not used.

D-40 Inductive Sensors

Dimensions

Note:All units are in millimeters unless otherwise indicated.

Pre-wired Models

E2A3-S08KS03-WP-@@

13 4

26.8

40

5

M8

×

1

(See note 1.)

Indicator (See note 2.)

Two, clamping nuts

Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm 2 ; Insulator diameter: 1.3 mm),

Standard length: 2 m

2. Operation indicator (yellow)

E2A3-M12KS06-WP-@@

17

5.5

34

50.4

12

(See note 1.)

Indicator (See note 2.)

M12

×

1

Two, clamping nuts

Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm

2

; Insulator diameter: 1.3 mm),

Standard length: 2 m

2. Operation indicator (yellow)

E2A3-M18KS11-WP-@@

24 6

39

59.6

15

(See note 1.)

Indicator (See note 2.)

M18

×

1

Two, clamping nuts

Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm 2 ; Insulator diameter: 1.3 mm),

Standard length: 2 m

2. Operation indicator (yellow)

E2A3-M30KS20-WP-@@

36

7

44

64.6

15

(See note 1.)

Indicator (See note 2.)

M30

×

1.5

Two, clamping nuts

Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm 2 ; Insulator diameter: 1.3 mm),

Standard length: 2 m

2. Operation indicator (yellow)

M12 Connector Models

E2A3-S08KS03-M1-@@

13

4

26.8

43.9

5

M12

×

1

M8

×

1

Indicator (See note.)

Two, clamping nuts

Note:Operation indicator (yellow LED, 4

×90°)

E2A3-M12KS06-M1-@@

17

5.5

34

49.2

12

M12

×

1

Indicator (See note.)

M12

×

1

Two, clamping nuts

Note:Operation indicator (yellow LED, 4

×90°)

E2A3-M18KS11-M1-@@

24 6

39

54.2

15

M12

×

1

Indicator (See note.)

M18

×

1

Two, clamping nuts

Note:Operation indicator (yellow LED, 4

×90°)

E2A3-M30KS20-M1-@@

36 7

44

59.2

15

M12

×

1

Indicator (See note.)

M30

×

1.5

Two, clamping nuts

Note:Operation indicator (yellow LED, 4

×90°)

E2A3

D-41

M8 Connector Models

E2A3-S08KS03-M5-@@

13 4

26.8

39.8

5

M8

×

1

M8

×

1

Indicator (See note.)

Two, clamping nuts

Note:Operation indicator (yellow LED, 4

×90°)

Mounting Hole Cutout Dimensions

F

External diameter of Proximity Sensor

Dimension F (mm)

M8

8.5 dia.

+0.5

0

M12

M18

12.5 dia.

+0.5

0

18.5 dia.

+0.5

0

M30

30.5 dia.

+0.5

0

D-42 Inductive Sensors

Safety Precautions

Precautions for Safe Use

WARNING

This product is not designed or rated for ensuring safety of persons.

Do not it for such purposes.

Power Supply

Do not impose an excessive voltage on the E2A3, otherwise it may be damaged. Do not impose AC current (100 to 240 VAC) on any DC

Model, otherwise it may be damaged.

Load Short-circuit

Do not short-circuit the load, or the E2A3 may be damaged.

The E2A3’s short-circuit protection function will be valid if the polarity of the supply voltage is correct and within the rated voltage range.

Precautions for Correct Use

Designing

Power Reset Time

The Proximity Sensor is ready to operate within 100 ms after power is supplied. If separate power supplies are connected to the Proximity Sensor and load, be sure to supply power to the Proximity Sensor before supplying power to the load.

Effects of Surrounding Metal

When mounting the E2A3 within a metal panel, ensure that the clearances given in the following tables are maintained.

l d dia.

m n

D

Model

E2A3

Shielded m

D n m d

Dimension

l

Material of surrounding metal

0.5 (*)

9

Ferrous metal

M8

Nonferrous metal

2 (*)

24

0.5

24

2 l

(Unit: mm)

36

2

36

Ferrous metal

2 (*)

18

M12

Non- ferrous metal

1 (*)

1

(Unit: mm)

Model

E2A3

Shielded

D n l m d

Dimension

Material of surrounding metal

Ferrous metal

4 (*)

33

54

4

54

M18

Nonferrous metal

2.5 (*)

2.5

60

90

6

90

Ferrous metal

6 (*)

M30

Nonferrous metal

4 (*)

4

* Using the nuts provided with the E2A3 allows mounting in the way shown below.

Nut provided with E2A3

Wiring

Be sure to wire the E2A3 and load correctly, otherwise it may be damaged.

Connection with No Load

Be sure to insert a load when wiring. Make sure to connect a proper load to the E2A3 during operation, otherwise it may damage internal elements.

Do not expose the product to flammable or explosive gases.

Do not disassemble, repair, or modify the product.

Power OFF

The Proximity Sensor may output a pulse signal when it is turned

OFF. Therefore, it is recommended that the load be turned OFF before turning OFF the Proximity Sensor.

Power Supply Transformer

When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer.

Mutual Interference

When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained.

A

B

A

Type

Shielded

Dimension

A

B

25

20

M8

35

M12

25

70

M18

45

(Unit: mm)

M30

110

70 l

= 0 mm

E2A3

D-43

Wiring

High-tension Lines

Wiring through Metal Conduit:

If there is a power or high-tension line near the cable of the Proximity

Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning.

Cable Extension

The standard cable length is less than 200 m.

The tractive force is 50 N.

Mounting

The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistance.

Do not tighten the nut with excessive force. A washer must be used with the nut.

Maintenance and Inspection

Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time.

1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects.

2. Check for loose wiring and connections, improper contacts, and line breakage.

3. Check for attachment or accumulation of metal powder or dust.

4. Check for abnormal temperature conditions and other environmental conditions.

5. Check for proper lighting of indicators (for models with a set indicator).

Never attempt to disassemble or repair the Sensor.

Environment

Water Resistivity

The Proximity Sensors are tested intensively on water resistance, but to ensure maximum performance and life expectancy, avoid immersion in water and provide protection from rain or snow.

Operating Environment

Store and operate the Proximity Sensor only within the given specifications.

Inrush Current

A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor. Connect the load to the Proximity

Sensor through a relay.

Type Torque

M8 Stainless Steel Model 9 N·m

M12

Brass Model ---

20 N·m

M18

M30

60 N·m

150 N·m

<SUITABILITY FOR USE>

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer’s application or use of the products.

Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.

<CHANGE IN SPECIFICATIONS>

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. D102-E2-01A-X

In the interest of product improvement, specifications are subject to change without notice.

D-44 Inductive Sensors

advertisement

Related manuals

Download PDF

advertisement