Below you will find brief information for Setup Kit 6030844. This manual describes how to use a Palm™ handheld computer to set up Force Control products. The instructions cover various aspects, including connecting the Palm to the system controller pigtail, using the ptelnet application, entering data with the stylus or keyboard, and capturing the Force Control Diagnostics Page as a memo. The manual also includes information on configuring the ptelnet software if required.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Cascade Setup Kit 6030844 User Manual | Manualzz
c
Setup
Instructions
Palm™ Setup Kit 6030844
for Force Control Products
Follow the steps below to use a Palm™ handheld computer to
set up Force Control products. (Acceptable Models M125,
M130, Tungsten T2, T3, W, C, Zire 71.)
CAUTION: Keep Palm on charger when not in use. Communications software will be lost if battery runs down. See
instructions on next page to configure ptelnet1 software if
required.
1
Connect the Palm to the system controller pigtail using
the Cascade adapter cable.
2
Turn the Palm on and tap the ‘Home’ icon to see the
Cascade page with ptelnet communications application
(‘computer screen’ icon).
3
Tap the ptelnet icon.
4
Tap the On button on menu bar that appears across
bottom of screen (‘On’ button highlights and blinking
cursor appears):
On-Off
3
2
8
‘Graffiti’
Writing
Area
Home (All
Applications)
9
2
AC0730.ill
Cycle the truck key ON/OFF, then ON. Palm screen may
show words ‘arm movement’.
6
Press the Enter key (Palm ‘squiggly line’ note pad key on
RH side of Palm). Words ‘arm movement’ may appear.
Use the Graffiti ™ writing area to enter data with the stylus
(preferred method) then press the Enter key.
9
An alternate method of entering data uses the onscreen keyboards shown opposite. Press the onscreen Done button first, before pressing the Enter
key.
Enter
(‘Note Pad’ Key)
Adapter Cable
(connect to
Force Control
controller pigtal)
IMPORTANT: Enter key (‘note pad’ icon) is used for all
setup procedures when using the Palm. Use to cycle
through Force Control menus and to return to main menu.
8
Keyboard
Icons
AC0727.ill
Press the Enter key again and follow the Force Control
prompts on-screen.
IMPORTANT: If the Enter key is pressed before the
on-screen Done button, the steps must be reentered.
It is not possible to back up in an AFC step or menu.
ptelnet
(Communications
Application)
5
7
Menu
Pull-Down
6,7
q w e r t y u i o p
a s d f g h j k l ; "
cap z x c v b n m , .
shift
space
- /
Done
abc 123 IntÕl
1 ptelnet V 0.6 shareware: Marcio Migueletto de Andrade at [email protected].
For more information refer to Palm documentation ‘Getting Started’ and ‘Read This First’.
AC0728.ill
£ ´
$
[ ] ( )
< > / =
@~ & #
Done
1
4
7
(
2
5
8
0
3
6
9
)
abc 123 IntÕl
- +
/ * :
. ,
space %
AC0729.ill
Part No. 6030841 R-4
cascade
corporation
For Technical Support . . .
Call: 1-800-227-2233
Fax: 1-888-329-8207
Internet: www.cascorp.com
Write: Cascade Corporation, PO Box 20187, Portland, OR 97294
To Order Parts . . .
Call: 1-888-227-2233
Fax: 1-888-329-0234
Internet: www.cascorp.com
Write: Cascade Corporation, 2501 Sheridan Ave., Springfield, OH 45505
Configuring Palm™ communications
program ptelnet (if required)
On-Off
Follow the steps below to configure ptelnet.
(If necessary to reload ptelnet, use CD from Cascade or
obtain as freeware for the Palm.
3
CAUTION: Keep Palm on charger when not in use. Communications software will be lost if battery runs down.
1
Turn the Palm On and tap the ‘Home’ icon to see the
Cascade page with ptelnet communications application
(‘computer screen’ icon). Tap the ptelnet icon.
2
Tap the ‘scroll down’ icon located on the lower LH side
of the Palm to bring up the ‘Options / Edit’ menu shown
opposite.
3
Tap Network and configure the screen as shown:
1
2
OK
Home Icon
(Applications)
127.0.0.1
23
Options
menu
10
10
Scroll
Down Icon
Cancel
AC0731.ill
1
AC0732.ill
4
ADAPTER
CABLES
Tap ‘scroll down’ icon again, then tap Serial and choose
one of the options shown based on the Palm model:
{
"#"
!
-OR-
$% " & -OR-
' ()
2
□ □ 4
AC0733.ill
5
3
Tap ‘scroll down’ icon again, then tap Terminal and
configure the screen as shown:
Parts List
REF QTY
□ AC0734.ill
AC0743.ill
1
2
3
4
–
–
1
1
1
1
1
1
PART NO.
6030844
6031161
6031330
6030842 ■
6030691 ■
6030840
6034054
DESCRIPTION
Mobile Setup Kit
Palm Handheld
Cable, Palm-to-Force Control
Cable, Palm-to-Serial ●
Cable, Serial-to-Force Control
ptelnet Communication Software
ptelnet CD Backup
● Palm Part Number P10804U.
■ May be substituted for 6031330.
Capturing Force Control
Diagnostics Page
On-Off
Follow the steps below to capture the Force Control Diagnostics Page as a ‘memo’ in the Palm computer. This
enables viewing the page or downloading (Palm ‘HotSync’)
to your PC.
1
Cycle the Clamp through a CLAMP/HOIST cycle,
leave truck running. (current settings will be stored in
Diagnostics Menu in controller).
2
Connect the Palm to the system controller pigtail using
the Cascade adapter cable.
3
Turn the Palm On and tap the ‘Home’ icon to see the
Cascade page with ptelnet communications application (‘computer screen’ icon).
4
Tap ptelnet, and tap On button on menu bar that
appears across bottom of screen (‘On’ button highlights,
blinking cursor appears):
AC0730.ill
5
6
7
8
9
Options
menu
Tap ‘log’ and check ‘Active’ and ‘Log Header’ (opposite), tap OK.
Cycle the truck key ON/OFF, then ON. Palm screen
may show words ‘arm movement’.
Press the Enter key (‘Note Pad squiggly line’ key on RH
side of Palm) and look for the words ‘arm movement’
Press the Enter key again which brings up the Force
Control main menu. Select units, then select menu 3 Diagnostics Page (bottom right).
Tap the ‘scroll down’ icon to bring up the ‘Options/
Edit’ menu again (top right).
11
Tap ‘log’ again, uncheck ‘Active’ and ‘Log header’,
check ‘Hex dump’ (opposite). Tap OK. Turn ptelnet
OFF by unhighlighting ‘On’ at bottom of screen:
AC0870.ill
Tap the ‘Home’ icon, locate and tap the ‘Memo Pad’
icon, which brings up the captured Diagnostics Page
(opposite) as the first new ‘memo’.
You can now view the Diagnostics Page on the Palm by
scrolling, or you can download (‘HotSync’) the page to
your PC. NOTE: PC must have Palm application
software to download the memo.
3
Home (All
Applications)
Icon
Scroll
Down
Icon
5
Tap the ‘scroll down’ icon located at the lower LH side
of the Palm character screen to bring up the ‘Options/
Edit’ menu shown opposite above.
10
12
5
AC0773.ill
Enter
(‘Note Pad’ Key)
Log options
□ Active
□ Log header
□ Hex dump
OK
Cancel
Log options
□ Active
□ Log header
□ Hex dump
OK
On Ctl Esc Kbd VT
Cancel
Macros
AC0869.ill
On Ctl Esc Kbd VT
Macros
AC0874.ill
❏
❏
■
❏
■
■
■
❏
❏
❏
❏
❏
❏
❏
❏
❏
❏
9,12
Switch 1
Closed
Switch 2
Open
Load Weight
2000 lbs.
Calculated Clamp Force
4000 lbs.
Measured Clamp Pressure
1400 psi
Calculated Clamp Pressure
1400 psi
Clamp Force/Weight Ratio
14
Pulsewidth
2800
Hoist Pressure
800 psi
Calibrated Load Pressure
800 psi
Calibrated Attachment Pressure
800 psi
Trimpot
50
Measured Pressures
1,1,2,1
EEprom values
1,1,1,1,7,208,14,12,10
EEprom values
10,240,175,3,132,3,32
EEprom values
0,245,1,2,14,144,1,252
EEprom values
12,128,3,232,10,240,4,176
Do you have questions you need
answered right now? Call your
nearest Cascade Service Department.
Visit us online at www.cascorp.com
AMERICAS
Cascade Corporation
U.S. Headquarters
2201 NE 201st
Fairview, OR 97024-9718
Tel: 800-CASCADE (227-2233)
Fax: 888-329-8207
Cascade do Brasil
Rua João Guerra, 134
Macuco, Santos - SP
Brasil 11015-130
Tel: 55-13-2105-8800
Fax: 55-13-2105-8899
Cascade Canada Inc.
5570 Timberlea Blvd.
Mississauga, Ontario
Canada L4W-4M6
Tel: 905-629-7777
Fax: 905-629-7785
EUROPE-AFRICA
Cascade Italia S.R.L.
European Headquarters
Via Dell’Artigianato 1
37030 Vago di Lavagno (VR)
Italy
Tel: 39-045-8989111
Fax: 39-045-8989160
Cascade (Africa) Pty. Ltd.
PO Box 625, Isando 1600
60A Steel Road
Sparton, Kempton Park
South Africa
Tel: 27-11-975-9240
Fax: 27-11-394-1147
ASIA-PACIFIC
Cascade Japan Ltd.
2-23, 2-Chome,
Kukuchi Nishimachi
Amagasaki, Hyogo
Japan, 661-0978
Tel: 81-6-6420-9771
Fax: 81-6-6420-9777
Cascade Korea
121B 9L Namdong Ind.
Complex, 691-8 Gojan-Dong
Namdong-Ku
Inchon, Korea
Tel: +82-32-821-2051
Fax: +82-32-821-2055
Cascade-Xiamen
No. 668 Yangguang Rd.
Xinyang Industrial Zone
Haicang, Xiamen City
Fujian Province
P.R. China 361026
Tel: 86-592-651-2500
Fax: 86-592-651-2571
Cascade Australia Pty. Ltd.
1445 Ipswich Road
Rocklea, QLD 4107
Australia
Tel: 1-800-227-223
Fax: +61 7 3373-7333
Cascade New Zealand
15 Ra Ora Drive
East Tamaki, Auckland
New Zealand
Tel: +64-9-273-9136
Fax: +64-9-273-9137
Sunstream Industries
Pte. Ltd.
18 Tuas South Street 5
Singapore 637796
Tel: +65-6795-7555
Fax: +65-6863-1368
Cascade India Material
Handling Private Limited
No 34, Global Trade Centre
1/1 Rambaugh Colony
Lal Bahadur Shastri Road,
Navi Peth, Pune 411 030
(Maharashtra) India
Phone: +91 020 2432 5490
Fax: +91 020 2433 0881
c
© Cascade Corporation 2004
5-2004
Part No. 6030841 R-4

advertisement

Key Features

  • Palm™ handheld computer setup
  • Force Control product configuration
  • ptelnet communication
  • Data entry with stylus or keyboard
  • Capture Force Control Diagnostics Page as memo
  • Palm™ HotSync for Diagnostics Page download
  • On-screen keyboard options
  • Enter key for menu navigation
  • Cascade adapter cable connection
  • Truck key cycle for diagnostics

Frequently Answers and Questions

How do I connect the Palm to the Force Control controller?
Connect the Palm to the system controller pigtail using the Cascade adapter cable.
What is the purpose of the ptelnet application?
The ptelnet application is used for communication with the Force Control system.
How do I enter data using the Palm?
You can enter data using the stylus in the 'Graffiti' writing area or use the on-screen keyboard.
How do I capture the Force Control Diagnostics Page?
Cycle the Clamp through a CLAMP/HOIST cycle, leave the truck running and follow the steps in the manual to capture the Diagnostics Page as a memo.

Related manuals

Download PDF

advertisement