East Coast Datacom UIC, 129010, 129028, 129011, 129029, 129012, 129030, 129013, 129031, 129014, 129032, 714000, 714001, 713015, 713016, 713017 User Manual

East Coast Datacom UIC, 129010, 129028, 129011, 129029, 129012, 129030, 129013, 129031, 129014, 129032, 714000, 714001, 713015, 713016, 713017 User Manual

Below you will find brief information for Universal Interface Converter UIC, V.35 Interface 129010, RS-530 Interface 129011, RS-422/449 Interface 129012, X.21 Interface 129013, RS-232 Interface 129014. The Universal Interface Converter (UIC) allows the user to connect devices with different data interfaces, such as V.35, RS-530, RS-422/449, X.21, RS-232, TTL and customer specific requests. Each data interface can be configured to force commonly used control signals such as DSR, DTR, Ring Indicate, Control and Indicate. The UIC has two TTL level interfaces for connecting each data interface. Installation is simple by plugging the DTE interface card into Port B and the DCE interface card into Port A.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Universal Interface Converter UIC User Manual | Manualzz

TABLE OF CONTENTS

CHAPTER 1 - INTRODUCTION

. . . . . . . . . . . . . . . . . . . . . .

1.1 FUNCTIONAL DESCRIPTION

. . . . . . . . . . . . . . . . . . . .

Page 1

Page 1

CHAPTER 2 - BASIC OPERATION

. . . . . . . . . . . . . . . . . . .

Page 2

2.1 FRONT PANEL INDICATORS

. . . . . . . . . . . . . . . . . . . .

2.2 FRONT PANEL SWITCHES

. . . . . . . . . . . . . . . . . . . . . .

2.3 REAR PANEL POWER CONNECTOR

. . . . . . . . . . . .

2.5 CLOCKING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.6 DATA INTERFACES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

Page 2

Page 2

Page 2

Page 2

2.7 DATA INTERFACE MODULE STRAPS

. . . . . . . . . . .

2.8 DATA INTERFACE REMOVAL

. . . . . . . . . . . . . . . . . . .

Page 3

Page 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CHAPTER 3 - INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . .

Page 4

3.1 VOLTAGE SELECTION

. . . . . . . . . . . . . . . . . . . . . . . . . .

3.2 VOLTAGE SELECTION FUSES

. . . . . . . . . . . . . . . . . .

3.3 POWER CONNECTION

. . . . . . . . . . . . . . . . . . . . . . . . .

3.4 DEFAULT CONFIGURATION SWITCH SETTINGS

Page 4

Page 4

Page 4

Page 5

3.5 DATA PORT CONNECTIONS

. . . . . . . . . . . . . . . . . . . .

3.6 SWITCH SETTINGS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5

Page 5

3.6.1 DIP SWITCHES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.0 - APPENDIX

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.1 V.35 INTERFACE CHART

. . . . . . . . . . . . . . . . . . . . . . .

5.0 - TECHNICAL SPECIFICATIONS

. . . . . . . . . . . . . . . . .

Page 6

Page 6

Page 7

OPERATIONS MANUAL

UNIVERSAL INTERFACE CONVERTER

UIC

22 May, 2000

FOR TECHNICAL SUPPORT CALL:

East Coast Datacom, Inc.

571 Haverty Court, STE N

Rockledge, FL 32955 USA

TEL: (800) 240-7948 or (321) 637-9922

FAX: (321) 637-9980

Email: [email protected]

Manufactured By

:

East Coast Datacom, Inc.

PT # 134000-A

UIC INSTALLATION AND OPERATIONS MANUAL

SAFETY WARNING

Always observe standard safety precautions during installation, operation and maintenance of this product. To avoid the possibility of electrical shock, be sure to disconnect the power cord from the power source before you remove the IEC power fuses or perform any repairs.

PROPRIETARY NOTICE

The information contained herein is proprietary to East Coast Datacom, Inc. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is provided by East Coast Datacom, Inc.

WARRANTY NOTICE

WARRANTIES: East Coast Datacom, Inc. (hereafter referred to as E.C.D.) warrants that its equipment is free from any defects in materials and workmanship. The warranty period shall be three (3) years from the date of shipment. E.C.D.'s sole obligation under its warranty is limited to the repair or replacement of defective equipment, provided it is returned to E.C.D., transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to accident, misuse, alterations or repair not made by E.C.D. or authorized by E.C.D. in writing.

PUBLICATION NOTICE

This manual has been compiled and checked for accuracy. The information in this manual does not constitute a warranty of performance. E.C.D. reserves the right to revise this publication and make changes from time to time in the content thereof.

E.C.D. assumes no liability for losses incurred as a result of out-of-date or incorrect information contained in this manual.

UIC INSTALLATION AND OPERATIONS MANUAL

CHAPTER 1 - INTRODUCTION

1.1 FUNCTIONAL DESCRIPTION

The Universal Interface Converter(UIC) allows the user to purchase a single product to convert interfaces between any combination of RS-232, V.35, RS-422/449, X.21, RS-530, TTL and customer specific requests. The UIC is shipped with any two user specified data interfaces.

Additional data interfaces are sold separately.

The individual data interfaces are available in DCE or DTE formats. Each data interface has the ability to force commonly used control signals such as DSR, DTR, Ring Indicate, Control and

Indicate.

The data interfaces may be mix and matched in any combination.

The UIC has two TTL level interfaces for connecting each data interface. Installation is fast and simple by plugging the DTE interface card into Port B and the DCE interface card into Port A. In all installations, Port B will always provide timing to Port A.

The UIC has status LED's for each attached data interface which allows the user to visually confirm the presence of control signals.

The UIC utilizes state of the art digital CMOS technology to provide a feature filled product at a very affordable price. Our Field Programmable Gate Array (FPGA) design has allowed us to offer this product with a wide selection of data interfaces.

The UIC is housed in a sturdy metal enclosure and operates on 110/220VAC.

The UIC has a three year warranty and a 24 hour turnaround on warranty repairs.

TYPICAL APPLICATION

Figure 1.1

Page 1

UIC INSTALLATION AND OPERATIONS MANUAL

CHAPTER 2 - BASIC OPERATION

2.1 FRONT PANEL INDICATORS

A Green LED marked POWER illuminates when AC Power has been applied. Two adjacent sets of Green LEDs, one for PORT A and another for PORT B, illuminate in union with individual port control signal activity. Both Port A and Port B indicators flash in union with Port A and Port B data interfaces(see section 2.4 Data Interfaces)

2.2 FRONT PANEL

SWITCHES

Located on the front panel of the UIC are two dip switches. The switches are marked

SW1 and SW2. For proper operation, SW1, positions 5 and 7 must be set to OFF. All other switches should be set to ON. Switch SW2 provides NO functions.

2.3 REAR PANEL

POWER CONNECTOR

Located on the back or rear of the product you will find an IEC POWER RECEPTACLE.

The supplied power cord plugs into this receptacle. This receptacle also contains a fuse drawer. Two (2) fuses are located in this compartment. For 110 VAC +/- 10% operation the unit is equipped with slow blow 160ma Fuses, Part # 714000. For 220

VAC +/- 10% operation the unit is equipped with slow blow 80ma Fuses, Part # 714001.

2.4 REAR PANEL DATA INTERFACE PORTS

Located adjacent to the IEC Power receptacle are the user selectable DATA

INTERFACE PORTS. The ports are marked PORT A and PORT B. The data interfaces plug into the UIC main printed circuit board through these openings. The top two screws on the interface module hold the card into place. Both Port A and Port B indicators flash in union with Port A and Port B data interfaces.

2.5 CLOCKING

The UIC must be externally clocked from PORT B.

2.6 DATA INTERFACES

The UIC has selectable DATA INTERFACES of V.35, RS-422/449, RS-530, X.21 and

RS-232. The data interfaces are purchased separate from the main UIC unit.

Page 2

UIC INSTALLATION AND OPERATIONS MANUAL

2.7

DATA INTERFACE MODULE STRAPS

The UIC has user selectable data interfaces that are purchased seperatly from the main

UIC unit. The available interfaces are V.35, RS-422/449, RS-530, X.21 and RS-232.

Each Data Interface Module has straps(3 pin header) that force select data interface signals. Please refer to each interface modules documentation for a detailed explanation of both control signals supported and the available options for forcing control signals.

2.8

DATA INTERFACE REMOVAL

Disconnect the AC power source from the UIC and disconnect the users data cables from the Data Interface Module(DIM). Located on back panel of the UIC are PORT A and PORT B. Each DIM is pluged into and out of these ports through mating connectors. Using a phillips screwdriver, remove the top two screws of the DIM. Gently pull the module from the UIC housing. It may be easier to remove the top cover and while holding the edges of the DIM, rock the DIM back and forth as you pull the DIM out of the socket.

Page 3

UIC INSTALLATION AND OPERATIONS MANUAL

CHAPTER 3 - INSTALLATION

CAUTION: Disconnect Power Before Servicing

ATTENTION: Couper Le Courant Avant l' Entretien

VORSICHT: Befor Deckung Abnehmen Mach Strom Zu

3.1 VOLTAGE SELECTION

It is very important to check that the unit is set to the correct voltage setting for your application before applying AC power. Located on the rear of the unit you will find a rotary 110/220 VAC switch. Using a coin or small screwdriver, gently turn the switch to the appropriate power position as required for your installation (110 or 220 VAC).

3.2 VOLTAGE SELECTION FUSES

Located on the back or rear of the product you will find an IEC Power receptacle. This receptacle contains a fuse drawer. Two (2) fuses are located in this compartment. For

110 VAC +/- 10% operation the unit is equipped with slow blow 5 x 20mm 160ma

Fuses, E.C.D. Part # 714000. For 220 VAC +/- 10% operation the unit is equipped with slow blow 5 x 20mm 80ma Fuses, E.C.D. Part # 714001. Spare fuses may be purchased by calling East Coast Datacom or by calling the fuse manufacturer: Little

Fuse at (312) 824-3024 or Shurter, Inc. at (707) 778-6311

Little Fuse Part #'s are: 160ma = 218.160 and 80ma = 218.080

Shurter, Inc. Part #'s are: 160ma = 034.3109 and 80ma = 034.3106

3.3 POWER CONNECTION

Before connecting the UIC to an AC power source the top cover should be installed with the supplied #6-32 screws. AC power is supplied to the unit through a 2.3m (6.6 ft) cord terminated by a grounded 3-prong plug. Select an appropriate location accessible to and within four to five feet of an AC outlet. The AC Power source MUST be grounded or the units Warranty will be void.

Power Connection

Figure 3-1

Page 4

UIC INSTALLATION AND OPERATIONS MANUAL

3.4 DEFAULT CONFIGURATION SWITCH SETTINGS

The UIC is configured prior to shipping with the Dip Switches set as follows:

1) Clock Source - Port B (Connect to DCE device)

2) Control Signals - Not Forced

3) Chassis to Signal GND - Not Connected

If your system application requires one or more of the default settings to be changed, this is accomplished via the front panel switches.

3.5 DATA PORT CONNECTIONS

Before applying AC Power to the unit, the users cabling to the UIC Data Interfaces should be connected. Straight through shielded cables should be used. PORT A must

always have a DCE interface module plugged into the port and connect to a DTE device. PORT B must always have a DTE interface module plugged into the port and connect to a DCE device.

3.6 SWITCH SETTINGS

3.6.1 DIP SWITCHES

The UIC has two Dip SwitchÂ’’s that are accessible via the front panel. The switches are marked SW1 and SW2. For proper operation, SW1, positions 5 and 7 must be set to

OFF. All other switches should be set to ON. Switch SW2 provides NO functions.

Page 5

UIC INSTALLATION AND OPERATIONS MANUAL

4.0 - APPENDIX

4.1 V.35 INTERFACE CHART

V.35 INTERFACE CHART

Pin

No

S

R

A

B

P

T

C

D

E

H

F

U

W

Y

AA

V

X

CCITT

Circuit

No.

101

102

103

103

104

104

105

106

107

108

109

113

113

114

114

115

115

Circui t Name

AA

AB

BA(A)

BA(B)

BB(A)

BB(B)

CA

CB

CC

CD

CF

DA(A)

DA(B)

DB(A)

DB(B)

DD(A)

DD(B)

Signal

Description

Protective Ground

Signal Ground

Transmit Data (A)

Transmit Data (B)

Receive Data (A)

Receive Data (B)

Request to Send

Clear to Send

Data Set Ready

Data Teminal Ready

Received Line Signal

Detect

External Transmit

Timing (A)

External Transmit

Timing (B)

Transmitter Signal

Element Timing (A)

Transmitter Signal

Element Timing (B)

Receiver Signal

Element Timing (A)

Receiver Signal

Element Timing (B)

From

DCE

---

---

X

X

X

X

X

X

X

X

X

To

DCE

---

---

X

X

X

X

X

X

Page 6

UIC INSTALLATION AND OPERATIONS MANUAL

5.0 - TECHNICAL SPECIFICATIONS

Warranty

Three Years, Return To Factory Application

Allows interconnection of a DCE and a DTE device which have different data interfaces, converting signal levels and the physical data interface

ORDERING INFORMATION

Model: UIC

Description: Universal Interface Converter

Capacity

One DCE and one DTE device

Interfaces Available:

Data Rates

Up to 10Mbps

DCE Cards(connects to a DTE)

V.35 DCE, PT# 129010

RS-530 DCE, PT# 129011

RS-422/449 DCE, PT# 129012

X.21 DCE, PT# 129013

RS-232 DCE, PT# 129014

Data Channel Interfaces

Available in V.35, RS-530, RS-422/449,

RS-232 or X.21

* other interfaces available by special order

DTE Cards (connects to a DCE)

V.35 DTE, PT# 129028

RS-530 DTE, PT# 129029

RS-422/449 DTE, PT# 129030

X.21 DTE, PT# 129031

RS-232 DTE, PT# 129032

Surge Protection

Main power supply

Power Source

100-120 to 200-220VAC @10%, 50/60Hz,

0.16/0.08A, external 110/220 volt select switch, IEC Power Inlet, (2) 5mm Fuses

INCLUDED WITH EACH UNIT:

1) Operations Manual

2) U.S.A. Grounded Power Cord, Part # 713015

3) Optional Power Cords

A) United Kingdom, Part # 713016

B) Continental Europe, Part # 713017

C) Other: Specify Country on Purchase Order

Environmental

Operating Temperature ....

32º to 122º F (0º to 50º C)

Relative Humidity .............

5 to 95%

Non-Condensing

Altitude ............................

0 to 10,000 feet

For further detailed technical information on this product, contact East Coast Datacom Technical

Assistance toll free at (800) 240-7948

Dimensions

Height .......

1.75 inches (4.44 cm)

Width ........

17.00 inches (43.18 cm)

Length .......

9.00 inches (22.86 cm)

OPTIONAL ACCESSORIES

1) Spare Data Center Fuses

A) 160ma Fuse, Qty (2) Part # 714000

B) 80ma Fuse, Qty (2) Part # 714001

Weight

2 pounds (0.914Kg)

Page 7

advertisement

Key Features

  • Converts between RS-232, V.35, RS-422/449, X.21, RS-530, TTL and customer specific requests
  • Allows for mixing and matching of data interfaces
  • Supports DCE and DTE formats
  • Has front panel LEDs for visual indication of control signals
  • Uses FPGA technology for versatility
  • Housed in a sturdy metal enclosure
  • Operates on 110/220VAC
  • Three year warranty
  • 24 hour turnaround on warranty repairs

Frequently Answers and Questions

How do I select the correct voltage for my application?
On the rear of the unit, you'll find a rotary 110/220 VAC switch. Use a coin or small screwdriver to turn the switch to the appropriate power position (110 or 220 VAC).
What are the default switch settings for the UIC?
The UIC is shipped with the following default settings: Clock Source - Port B (Connect to DCE device), Control Signals - Not Forced, Chassis to Signal GND - Not Connected. You can change these settings using the front panel switches.
How do I connect the data cables to the UIC?
Connect the user's data cables to the UIC Data Interfaces before applying AC Power. Use straight through shielded cables. PORT A should always have a DCE interface module plugged into the port and connect to a DTE device. PORT B should always have a DTE interface module plugged into the port and connect to a DCE device.
What are the fuse types used for the UIC?
For 110 VAC +/- 10% operation, you'll need slow blow 5 x 20mm 160ma Fuses, E.C.D. Part # 714000. For 220 VAC +/- 10% operation, you'll need slow blow 5 x 20mm 80ma Fuses, E.C.D. Part # 714001.