- Home
- Domestic appliances
- Small kitchen appliances
- Coffee makers
- American Fyre Designs
- 660 Amphora
- User manual
- 24 Pages
American Fyre Designs 660 Amphora fire urn Installation & owner's manual
Below you will find brief information for 660 Amphora.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
INSTALLATION &
OWNER’S MANUAL
Series: 660
660 series shown
Certifi ed to:
ANSI Z21.97/CSA 2.41 for outdoor decorative gas appliances
F13-042
WARNING: For Outdoor Use Only
AMPHORA OUTDOOR FIRE URNS
WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
- A propane cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open fl ame.
3. If odor continues, keep away from the appliance and immediately call your gas supplier or fi re department.
Installation and service must be performed by an NFI Certifi ed or other qualifi ed professional installer, service agency, or gas supplier.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car, or home.
INSTALLER & CONSUMER: These instructions MUST be retained with this appliance for future reference.
Important: Read these instructions carefully
before starting installation of the unit.
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
This appliance is designed as an attended
appliance. Adults must be present when the
unit is operating. DO NOT leave this unit burning when unattended. If this product is left burning unattended, it may cause damage or serious injury.
IMPORTANT
For safe operation and proper performance of this product and to comply with certification, listings, and building code acceptances, use ONLY
Peterson AFD controls, parts, and accessories that have been specifi cally listed or certifi ed for use with this burner system. Use of other controls, parts, or accessories is prohibited and will void all warranties, certifi cations, listings, and building code approvals, and may cause property damage, personal injury, and loss of life.
CODE AND SUPPLY REQUIREMENTS:
The installation must conform with local codes and ordinances, or, in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1.
REV 1 - 1401201630
1
L-H2-004
INSTALLATION ET
MODE D'EMPLOI
Series: 660
Série
660 montré
Certifi é à:
ANSI Z21.97/CSA 2.41 pour les appareils à gaz décoratifs extérieurs
F13-042
AVERTISSEMENT: Pour l'usage extérieur seulement
AMPHORA PLEIN AIR URNES INCENDIE
AVERTISSEMENT: Si l'information en ce manuel n'est pas suivie exactement, une incendie ou une explosion peut résulter entraînant des dégats matériels, le dommage corporel ou des pertes humaines.
d'INSTALLATEUR; CONSOMMATEUR: Ces instructions DOIVENT être maintenues avec cet appareil pour la future référence.
Important: Lisez ces instructions soigneusement avant de commencer l'installation de l'unité.
- Ne pas entreposer ni utiliser d'essence ou d'autres vapeurs et liquides infl ammables
à proximité de cet appareil ou de tout autre.
- Une bouteille de propane non branchée ne doit pas être entreposée à proximité de cet ou tout autre appareil.
AVERTISSEMENT
L'installation, l'ajustement, le changement, le service, ou l'entretien inexact peuvent causer des dégats matériels, le dommage corporel, ou des pertes humaines. Lisez l'installation, l'opération et les instructions d'entretien complètement avant d'installer ou entretenir cet équipement.
DANGER
Si vous sentez une odeur de gaz:
1. Coupez le gaz à l'appareil.
2. Éteindre toute fl amme nue.
3. Si l'odeur persiste, éloignez-vous de l'appareil et appelez immédiatement votre fournisseur de gaz ou les pompiers.
L'installation et le service doivent être assurés par un NFI certifi é ou toute autre installateur, agence de service, ou fournisseur professionnelle qualifi ée de gaz.
DANGER
DANGER MONOXYDE DE CARBONE
Cet appareil peut produire du monoxyde de carbone n'a pas d'odeur qui.
Son utilisation dans un espace clos peut vous tuer.
Ne jamais utiliser cet appareil dans un espace clos comme une caravane, tente, véhicule ou maison.
Cet appareil est conçu comme appareil occupé. Les adultes doivent être présent quand l'unité fonctionne.
Ne laissez pas ce burning d'unité si sans surveillance.
Si ce produit est laissé sans surveillance brûlant, il peut causer des dommages ou des dommages sérieux.
IMPORTANT
Pour l'exploitation sûre et l'exécution appropriée de ce produit et pour se conformer à la certifi cation, aux listes, et aux acceptations de codes du bâtiment, commandes, pièces, et accessoires de Peterson d'utilisation SEULEMENT qui ont été spécifi quement
énumérés ou certifi és pour l'usage avec ce système de brûleur. L'utilisation d'autres commandes, pièces, ou accessoires est interdite et videra toutes les garanties, certifi cations, listes, et approbations de codes du bâtiment, et peut causer des dégats matériels, le dommage corporel, et des pertes humaines.
CONDITIONS DE CODE ET D'APPROVISIONNEMENT:
L'installation doit se conformer aux codes locaux et aux ordonnances, ou, en l'absence des codes locaux, au plus défunt code national de gaz de carburant, la
norme ANSI Z223.1.
REV 1 - 1401201630
2
L-H2-004
TABLE OF CONTENTS
GETTING STARTED
PRE-INSTALLATION AND PREPARATION SAFETY GUIDELINES .....................................................
4
INSTALLATION SAFETY GUIDELINES ...................................................................................................
5
OPERATING THE UNIT SAFELY AND CORRECTLY .............................................................................
5
SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS ..........................................................
7
SPECIFICATIONS AND DIMENSIONS ......................................................................................................
8
MINIMUM CLEARANCES TO COMBUSTIBLES ....................................................................................
9
PARTS LIST ................................................................................................................................................
10
INSTALLATION
IMPORTANT SAFETY INFORMATION ..................................................................................................
12
FIRE URN INSTALLATION......................................................................................................................
12
BEFORE YOU BEGIN
...........................................................................................................................
12
LOCATION
..........................................................................................................................................
12
CONNECT GAS SUPPLY
.......................................................................................................................
13
LEAK TEST
...........................................................................................................................................
14
REPLACE STORAGE DOOR
..................................................................................................................
14
DECORATIVE MEDIA PLACEMENT .....................................................................................................
15
LAVA MEDIA
........................................................................................................................................
15
VOLCANIC STONE
..............................................................................................................................
15
GLASS MEDIA
......................................................................................................................................
15
OPTIONAL COVERS ................................................................................................................................
16
OPTIONAL GFRC COVER
....................................................................................................................
16
OPTIONAL FABRIC COVER
..................................................................................................................
16
USE, CARE, & SERVICE
LIGHTING INSTRUCTIONS - CONTROL KNOB MODELS ...............................................................
17
LIGHTING INSTRUCTIONS CONTROL ................................................................................................
17
FOR YOUR SAFETY, READ BEFORE LIGHTING
...................................................................................
17
TO SHUT OFF GAS TO THE APPLIANCE
.............................................................................................
17
LIGHTING INSTRUCTIONS - KEY VALVE MODELS .........................................................................
19
FOR YOUR SAFETY, READ BEFORE LIGHTING
...................................................................................
19
TO SHUT OFF GAS TO THE APPLIANCE
.............................................................................................
19
SERVICING AND CLEANING .................................................................................................................
21
ANNUAL CLEAN / INSPECTION GUIDELINES
.....................................................................................
21
FUEL CONVERSION KITS
....................................................................................................................
21
NOTES PAGE .............................................................................................................................................
22
TROUBLESHOOTING ..............................................................................................................................
23
WARRANTY ..............................................................................................................................................
24
IMPORTANT SAFETY INFORMATION
Congratulations on your purchase of an American Fyre Designs outdoor gas fi re urn. Made with pride in America, your new fi re urn complies with national safety standards and when installed per these instructions and used as intended it will provide warmth and comfort to your outdoor area for many years.
Prior to installation and operation ensure that all specifi cations, dimensions, and minimum clearances stated in this manual are observed. You must read all warnings and safety information, and understand all of the information in this manual. All installation requirements must be observed and met.
REV 1 - 1401201630
3
L-H2-004
PRE-INSTALLATION AND PREPARATION SAFETY GUIDELINES
A. Before installing this unit, check the MINIMUM CLEARANCE TO COMBUSTIBLES section to ensure that the surrounding area is properly sized for the installation.
B. The unit is for outdoor use only. DO NOT install or use this appliance inside a building, garage, or any other enclosed area, including recreational vehicles and/or boats. THIS UNIT MUST BE INSTALLED IN SUCH A
MANNER THAT ALL VENT OPENINGS ON THE UNIT REMAIN CLEAR AND FREE OF ALL OBSTRUCTIONS
AT ALL TIMES AND DURING ALL WEATHER CONDITIONS.
C. CHECK GAS TYPE (natural gas or propane): The gas supply you intend to use may not be the same as that stated on the unit rating plate as purchased. If the gas supply is different, convert the unit to the gas type
you intend to use (IF PERMITTED). See the FUEL CONVERSION KIT section and contact the dealer for assistance.
D. FOR NATURAL GAS: The minimum inlet gas-supply pressure for purposes of input adjustment is 5" water column (w.c.), and the maximum inlet gas-supply pressure is 10.5 " w.c. FOR PROPANE: The minimum inlet gas-supply pressure for purposes of input adjustment is 8" w.c., and the maximum inlet gas-supply pressure is 13" w.c. DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM
PRESSURE IS EXCEEDED.
E. The gas piping system must be sized to provide minimum inlet pressure at the maximum fl ow rate
(BTU/hr). Undue pressure loss will occur if the pipe is too small, or the run is too long. Gas supply pipe must be 1/2" minimum interior diameter. If the gas line is longer than 20', a larger diameter line may be necessary.
Refer to the NFPA 54 guidelines for further details.
F. For installations at elevations above 2,000 ft., contact your local dealer or gas supplier before installing. Input ratings should be reduced approximately 4% for each 1,000 ft. above sea level. Refer to the National Fuel Gas
Code.
G. The unit and its individual shutoff valve must be disconnected from the gas-supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). This is accomplished by closing the gas-supply line valve. The unit must be isolated from the gas-supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas-supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
H. When an appliance is for connection to a fi xed piping system, the installation must conform with local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1/NFPA 54; International Fuel
Gas Code, Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code,
B149.2, as applicable. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the National Electrical Code, ANSI/NFPA 70; or the Canadian
Electrical Code, CSA C22.1, if applicable.
I. INSTALLER NOTE: This unit should be installed so that it can be removed if service is required.
J. GAS-SUPPLY PLUMBING REQUIREMENTS
Apply only joint compounds that are resistant to all gasses on all male pipe fi ttings. Make sure to tighten every joint securely. Do not use pipe joint compound to connect fl are fi ttings. Bring the gas-supply pipe up from beneath the enclosure near its center (if applicable).
CAUTION: Installation and maintenance must be done by an NFI Certifi ed or other qualifi ed professional installer.
Installer, read these instructions before installing this product. Be sure you understand all safety precautions and warnings contained in this manual.
Note: An external on/off valve in the gas line is required for safety when the unit is not in use. It also provides for convenient maintenance and repair.
4
INSTALLATION SAFETY GUIDELINES
A. Installation and repair should be done by a qualifi ed service person. The appliance should be inspected before use and at least annually by a qualifi ed service person. More frequent cleaning may be required as necessary.
It is imperative that control compartment, burners and circulating air passageways of the appliance are kept clean.
B. Carefully inspect for shipping damage. If any parts are damaged, call the dealer.
C. WEAR GLOVES AND USE EXTREME CAUTION WHENEVER INSTALLING AND HANDLING THIS
PRODUCT AND ITS ACCESSORIES AS CERTAIN COMPONENTS HAVE SHARP EDGES THAT CAN
CAUSE PERSONAL INJURY.
D. Correct installation and proper placement of the unit and decorative media is crucial to the safe performance of the unit. See installation instructions for further information.
E. DO NOT install the unit under any overhead combustible materials that are less than 8 feet above the top of the unit.
F. Ensure that the unit is installed on a hard and level surface.
G. Ensure that the unit is installed in such a manner that all vent openings on the unit remain clear and free of all obstructions at all times and during all weather conditions.
H. Due to high temperatures, the unit must be located out of traffi c areas and away from combustibles.
OPERATING THE UNIT SAFELY AND CORRECTLY
A. This product is a decorative gas appliance. It is not a cooking appliance.
B. This appliance is only intended for operation in temperatures above 32°F.
C. When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF.
D. Children MUST be carefully supervised when they are in the area of this appliance.
E. DO NOT sit or place any part of the body, clothing, or other fl ammable materials on or near the unit surround.
Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition. DO NOT lean over the unit when lighting or when in use.
F. Every time you use the unit, make sure that:
1. The area around the unit is clear and free from combustible materials, gasoline and other fl ammable vapors and liquids.
2. There is no blockage of the airfl ow through the vent openings located on the unit.
3. The hose is inspected (if applicable). See the SAFE USE & MAINTENANCE OF PROPANE-GAS CYLINDERS section.
G. WARNING: HOT WHILE IN OPERATION AND FOLLOWING OPERATION. Serious injury can occur! DO NOT throw trash, paper, or other fl ammable materials onto the unit. DO NOT leave in operation when unattended.
WARNING: DO NOT operate this unit in the rain.
H. SOLID FUEL MUST NOT BE BURNED in the unit.
I. DO NOT continue using if you smell unusual odors, or have headaches, nausea, or dizziness.
J. DO NOT store any combustible materials, gasoline, and any other fl ammable vapors/liquids in the vicinity of the unit. Provide adequate clearance for servicing and operation.
K. Matches, paper, garbage, or any other material must not be thrown onto the unit or into the fl ame.
L. DO NOT use the unit if any part of it has been underwater. Immediately call a qualifi ed professional service technician to inspect the unit and to replace any part of the control system and any gas control that has been underwater.
5
UTILISATION SÛRE ET ENTRETIEN DES CYLINDRES DE GAZ DE PROPANE
IMPORTANT POUR VOTRE SÛRETÉ
LISEZ ET SUIVEZ TOUS LES AVERTISSEMENTS ÉQUIPÉS DE VOTRE CYLINDRE DE GAZ DE PROPANE.
En actionnant cet appareil avec un cylindre de gaz de propane ON DOIT observer ces instructions et avertissements.
LE MANQUE DE FAIRE AINSI PEUT AVOIR COMME CONSÉQUENCE UNE INCENDIE OU UNE EXPLOSION SÉRIEUSE.
CYLINDRE ET CONDITIONS ET
CARACTÉRISTIQUES DE CONNECTEUR
a. Des cylindres et les valves de gaz de propane doivent être maintenus en bon état et doivent être remplacés s’il y a des dommages évidents au cylindre ou à la valve.
main dans le sens des aiguilles d’une montre pour engager les fi ls et pour serrer jusqu’à ce que douillettement. L’utilisation des pinces ou de la clé ne devrait pas être nécessaire. Seulement le propane marqué par cylindres doit être employé.
Pour débrancher: Tournez l’écrou de main dans le sens contraire des aiguilles d’une montre jusqu’à isolé (fi g. 6-1).
b. Ce gril, une fois utilisé avec un cylindre, devrait être relié à un gallon de la norme 5 (20lb.) cylindre de gaz de propane
équipé d’un OPD (remplissez au-dessus du niveau le dispositif d’empêchement). L’OPD a été exigé sur tous les cylindres vendus depuis octobre 1.1998 pour empêcher le remplissage excessif.
Important:
Avant d’employer le gril, et ensuite chaque fois que le cylindre est enlevé et rattaché, examinez tous les raccordements pour déceler les fuites. Arrêtez les valves de gril et ouvrez la valve principale de cylindre, puis vérifi ez les raccordements avec de l’eau savonneux.
Réparez toutes les fuites avant d’allumer le gril.
c. Les dimensions de cylindre devraient être approximativement
12"(30.5cm) de diamètre et 18" (45.7cm) hauts. Des cylindres doivent être construits et marqués selon les caractéristiques pour des cylindres de gaz de propane du département des ETATS-UNIS du transport (D.O.T.) ou le niveau national du Canada, du CAN/CSA-B339, des cylindres, des sphères et des tubes pour le transport des marchandises dangereuses.
ATTENTION: Tournez toujours la valve principale de cylindre de propane au loin après chaque utilisation, et avant de déplacer le gril et le cylindre, ou débrancher l’accouplement. Cette valve doit rester fermée et le cylindre a débranché alors que l’appareil n’est pas en service, quoique l’écoulement de gaz soit arrêté par un dispositif de sûreté quand le coupleur est débranché.
d. Le cylindre doit inclure un collier pour protéger la valve de cylindre et le circuit d’alimentation de cylindre doit être assuré le retrait de vapeur.
Inspectez soigneusement l’ensemble de tuyau chaque fois avant que le gaz soit allumé. Un tuyau criqué ou frangé devrait
être remplacé immédiatement.
e. Le montage du régulateur de pression et le fl exible (Fig. 6-1) fourni avec cet appareil au gaz en plein air (modèles au propane seulement) doit être utilisé. Assemblées d'origine et régulateur de pression et le tuyau de remplacement doivent
être ceux spécifi és par le fabricant pour le raccordement d'un dispositif de cylindre de liaison identifi ée comme de type I par le 21.58-2005/CGA ANSI Z 1.6 à 2005 (voir liste des pièces pour les informations de commande).
Si l'appareil est stocké à l'intérieur, le cylindre doit être disconnected et a enlevé. Des cylindres Disconnected doivent être stockés dehors, hors de la portée des enfants, avec les prises de valve fi letées étroitement installées, et ne doivent pas être stockés dans un bâtiment, le garage, ou n'importe quel autre secteur inclus.
POUR VOTRE SÛRETÉ
a. Ne stockez pas un cylindre de gaz disponible de propane dessous ou ne vous approchez pas de cet appareil.
f. La valve de cylindre de gaz de propane doit être équipée d’un dispositif d’accouplement de raccordement de cylindre, décrit comme type I dans la norme défi nie dans le e. de paragraphe ci-dessus. Ce dispositif est généralement décrit comme coupleur rapide de fi l de point culminant.
g. Si votre cylindre de gaz de propane vient avec une prise de la poussière, placez le bouchon anti-poussière sur la sortie de valve de cylindre toutes les fois que le cylindre n’est pas en service.
OPÉRATION DE COUPLEUR RAPIDE
b. Ne remplissez jamais cylindre au delà de 80 pour cent de plein.
c. SI L’INFORMATION DANS “A” ET “B” N’EST PAS SUIVIE
EXACTEMENT, UN FEU CAUSANT LA MORT OU DES
DOMMAGES SÉRIEUX PEUT SE PRODUIRE.
Fig. 6-1 type coupleur rapide de fi l de point culminant d’I
Volant de commande
QCC
Type 1
Valve
1
4
Ajustage de précision en laiton de fi l de point culminant
3
Régulateur
U L
Pour relier le regulator/hose à l’ajustage de précision de
valve de cylindre de gaz de propane: Serrez l’écrou de main sur le régulateur au-dessus de l’ajustage de précision de fi l de point culminant sur la valve de cylindre. Tournez l’écrou de
Valve de décompression
Indicateur de niveau de liquide
(facultatif)
2
Écrou de main avec le fi l de point culminant.
Passage
Tuyau
6
SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS
IMPORTANT FOR YOUR SAFETY
READ AND FOLLOW ALL WARNINGS PROVIDED WITH THE PROPANE-GAS CYLINDER.
When operating this appliance with a propane-gas cylinder, these instructions and warnings MUST be observed.
FAILURE TO DO SO MAY RESULT IN A SERIOUS FIRE OR EXPLOSION.
CYLINDER/CONNECTOR REQUIREMENTS
a. Propane-gas cylinders, valves, and hoses must be maintained in good condition and must be replaced if there is visible damage to either the cylinder or valve. If the hose is cut or shows excessive abrasion or wear, it must be replaced before using the gas appliance (see e.).
b. This unit, when used with a cylinder, should be connected to a standard 5-gallon (20 lb.) propane-gas cylinder equipped with an OPD (Overfi ll Prevention Device).
The OPD has been required on all cylinders sold since
October 1,1998, to prevent overfi lling.
c. Cylinder dimensions should be approximately 12" (30.5 cm) in diameter and 18" (45.7 cm) high. Cylinders must be constructed and marked in accordance with the
Specifi cations for Propane Gas Cylinders of the U.S.
Department of Transportation (D.O.T.) or the National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres, and Tubes for Transportation of Dangerous
Goods.
d. The cylinder used must include a collar to protect the cylinder valve, and the cylinder supply system must be arranged for vapor withdrawal.
e. The pressure regulator and hose assembly (Fig. 7-1)
supplied with this outdoor gas appliance (L.P. models only) must be used. Original and replacement pressure regulator and hose assemblies must be those specifi ed by the manufacturer for connection with a cylinder connecting device identifi ed as Type I by the ANSI Z
21.58-2005/CGA 1.6-2005 (see PARTS LIST for ordering information).
f. The propane-gas cylinder valve must be equipped with a cylinder connection coupling device, described as Type I in the standard defi ned in paragraph e. above. This device is commonly described as an Acme thread quick coupler.
g. If the propane-gas cylinder comes with a dust plug, place the dust cap on the cylinder valve outlet whenever the cylinder is not in use.
QUICK COUPLER OPERATION
To connect the regulator/hose assembly to the propane-
gas cylinder valve fi tting: Press the hand nut on the regulator over the Acme thread fi tting on the cylinder valve. Turn the hand nut clockwise to engage the threads and tighten until snug.
The use of pliers or a wrench should not be necessary. Only cylinders marked “propane” may be used.
To disconnect: Turn the hand nut counterclockwise until detached (Fig. 7-1).
Important:
Before using the unit, and after each time the cylinder is removed and reattached, check the hose for wear (see a.) and check all connections for leaks. Turn off the unit valves and open the main cylinder valve, then check connections with soapy water. Repair any leaks before lighting the unit.
CAUTION: Always turn the propane cylinder main valve off after each use, and before moving the unit and cylinder or disconnecting the coupling.
This valve must remain closed and the cylinder disconnected while the appliance is not in use, even though the gas fl ow is stopped by a safety feature when the coupler is disconnected.
Carefully inspect the hose assembly each time before the gas is turned on. A cracked or frayed hose should be replaced immediately.
If the appliance is stored indoors, the cylinder must be disconnected and removed. Disconnected cylinders must be stored outdoors, out of the reach of children, with threaded valve plugs tightly installed, and must not be stored in a building, garage, or any other enclosed area.
FOR YOUR SAFETY
a. DO NOT store a spare propane-gas cylinder under or near this appliance.
b. NEVER fi ll the cylinder beyond 80-percent full.
c. IF THE INFORMATION IN a. AND b. IS NOT FOLLOWED
EXACTLY, A FIRE CAUSING DEATH OR SERIOUS
INJURY MAY OCCUR.
QCC
Type 1 valve
Fig. 7-1 Type I Acme thread quick coupler
Hand wheel
Brass Acme thread fi tting
Regulator
Pressure relief valve
U L
Liquid level indicator
(optional)
Hand nut with Acme thread
Vent
Hose
7
Fire Urn Style
Amphora Fire Urn (660)
SPECIFICATIONS AND DIMENSIONS
Nat.
BTUs
L.P.
60,000 50,000
Table 1 - Product Dimensions
Dimensions
22" dia. x 29" h
Weight / Pieces
150 / 1 pc
Diameter
Height
8
SPECIFICATIONS AND DIMENSIONS (cont.)
Follow the recommendations below for decorative media amounts. All decorative media options are purchased separately. Contact your local American Fyre Designs dealer when ordering.
When using lava media:
Fire Urn Style(s)
Recommended Amount of Lava Media
Lava Granules Option Lava Coals Option
Amphora Urn 8 lbs 6 lbs
When using volcanic stone in addition to above mentioned lava media, use VS-12 (12 lbs).
Table 2 - Lava Recommendations
When using glass media:
Amphora Urn
Fire Urn Style(s) Recommended Amount of Glass
15 lbs
Table 3 - Glass Recommendations
MINIMUM CLEARANCES TO COMBUSTIBLES
The dimensions shown below are MINIMUM CLEARANCES to maintain when you install the unit.
ALL CLEARANCES AND INFORMATION STATED HERE MUST BE MAINTAINED AND FOLLOWED.
Description
Side clearance
(from burner edge to combustible construction)
Clearance above unit
Clearance below unit
Dimension
Table 4 - Minimum Clearances to Combustibles
3 ft
8 ft
0"
8 ft
3 ft side clearance
(burner edge to combustible construction)
3 ft side clearance
(burner edge to combustible construction)
Floor must be a hard, level surface. Combustible materials ok.
9
PARTS LIST
• In addition to the Replacement Parts List, reference the identifi cation parts list.
• Your fi re urn is packaged onto 1 pallet.
• Decorative media is purchased and packaged separately. Various styles are available.
• Decorative media and replacement parts can be ordered from your local American Fyre
Designs dealer.
• Select models are illustrated
(your model may vary)
IMPORTANT
Remove all packing material (including any protective coatings) and discard prior to use.
SOME COMPONENTS
ARE HEAVY
HANDLE WITH CARE
REPLACEMENT PARTS LIST - V2 MODELS
Item Description
1.
or
12" star burner, only (Nat.)
12" star burner, only (L.P.)
2.
3.
4.
or
Control valve w/ knob assembly
Pressure regulator (Nat. only)
Flex connector (Nat. only)
L.P. regulator and hose assembly (L.P. only)
Part No.
OCBS-12
OCBS-12P
SV-61
PR-1NAT
CK-5-24
5110-07
Qty.
1
1
1
1
1
1
1
4
10
2
3
PARTS LIST (cont.)
REPLACEMENT PARTS LIST - K2 MODELS
Item Description
1.
or
12" star burner, only (Nat.)
12" star burner, only (L.P.)
2.
3.
Key valve (including key)
Key (only) *
4.
5.
or
Pressure regulator (Nat. only)
Flex connector (Nat. only)
L.P. regulator and hose assembly (L.P. only)
* Not shown
Part No.
OCBS-12
OCBS-12P
AV-30
VK-1
PR-1NAT
CK-5-24
5110-07
Qty.
1
1
1
1
1
1
1
1
5
4
2
IDENTIFICATION PARTS LIST (One-piece models)
Amphora (660)
Item Description
1.
Complete enclosure assembly
2.
Base door
Qty.
1
1
1
2
Amphora Fire Urn shown
11
IMPORTANT SAFETY INFORMATION
BE CAREFUL
If not installed and used correctly per these instructions, this product can cause serious injury.
CAUTION: Installation and maintenance must be done by an NFI Certifi ed or other qualifi ed professional service technician. Read these instructions before installing this unit. Be sure you understand all safety precautions and warnings contained in this manual.
A. FOR OUTDOOR USE ONLY.
B. When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF.
C. WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT MODIFY THIS unit OR
ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL. Any other change may be dangerous.
Improper installation or use of the unit can cause serious injury or death from fi re, burns, explosions, or carbon monoxide poisoning.
D. Check state and local codes to determine if the unit is permitted in your locality before installation.
E. The manual valve allows for an adjustable fl ame height. THESE SETTINGS MUST ALWAYS BE HIGH ENOUGH
FOR THE FLAME TO BE CLEARLY VISIBLE. WHEN LIGHTING THE UNIT, ALWAYS LIGHT ON HIGH.
FIRE URN INSTALLATION
BEFORE YOU BEGIN
Important: Prior to installation ensure that all specifi cations, dimensions, and minimum clearances stated in this manual are observed. You must read all warnings and safety information, and understand all of the information in this manual. All installation requirements must be observed and met.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury.
• Confi rm the installation site accommodates the unit per the requirements in this manual.
• Be sure the gas supply (propane or natural) is turned off at its source.
LOCATION
While following all requirements and safety information in this manual (see MINIMUM CLEARANCES TO
COMBUSTIBLES section); CAREFULLY locate the unit on a hard and level surface.
Note: For fi re urns, a combustible surface is permitted.
HANDLING OF THE UNIT REQUIRES TWO OR MORE PEOPLE.
EXERCISE EXTREME CARE DURING ASSEMBLY AND INSTALLATION.
12
FIRE URN INSTALLATION (cont.)
CONNECT GAS SUPPLY
Important: Before installation, be sure the gas supply
(propane or natural) is turned off at its source.
To access the interior of the urn, remove the storage door.
Remove by fi rst turning the door handle counter-clockwise, then carefully pulling the door upward and outward. The bottom of the door has metal tabs that must clear the base.
See Fig. 13-1. Store in a safe location.
To Connect To a Propane Cylinder:
1. Locate the regulator hose assembly that is already installed on the rear of the valve assembly.
2. Attach the regulator end of the hose assembly to a propane cylinder (not included) and tighten (see Fig.
13-2).
3. The propane cylinder (not included) is to be located inside the base of the unit, via the storage door opening
(see Fig. 13-3).
To Connect To a Natural or Household Propane Gas
Supply:
1. Locate the fl ex connector that is already installed on the rear of the valve assembly.
2. Bring the gas supply pipe up from beneath the unit near its center. Observe all codes.
Important: Locate the gas supply line out of pathways where people may trip over it or in areas where the line may way be subject to accidental damage (if applicable).
3. Install the supplied fl are adapter to the gas supply (NPT) using a gas pipe sealing compound or Tefl on tape (see
Fig. 13-4).
4. Connect the fl ex connector to the fl are adapter (see
Fig. 13-4).
Fig. 13-1 Remove storage door
Propane cylinder
UL
B
A
Regulator/hose assy
(coming from valve assy)
Fig. 13-2 Connecting to an L.P. cylinder
Fig. 13-3 L.P. Cylinder placement
Flex connector
(coming from valve assy)
Flare adaptor
Gas supply
Fig. 13-4 Connecting to a gas line
13
FIRE URN INSTALLATION (cont.)
LEAK TEST
Turn on the gas supply, ignite the burner, and test at all connections for leaks using a soapy water solution. If bubbles appear, a leak is present. Turn off the gas and tighten at all connections. Repeat until no leaks are present. If a leak persists, turn off the gas supply and contact the local gas company or dealer. NEVER USE A FLAME TO CHECK
FOR LEAKS.
REPLACE STORAGE DOOR
Replace the storage door (that was previously removed during the assembly section). Ensure the door is secure in place (see Fig. 14-1). Door design may vary.
Fig. 14-1 Replace storage door
14
DECORATIVE MEDIA PLACEMENT
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury.
CAUTION: Be sure the unit and the decorative media are completely cool anytime the media is handled.
Wear gloves whenever installing and handling as certain media may have sharp edges that can cause personal injury.
This unit has several options for decorative media. The decorative media is purchased and packaged separately.
Contact your local American Fyre Designs dealer for ordering information. Locate the section(s) below that apply to your option(s) chosen and install accordingly.
Reference the SPECIFICATIONS AND DIMENSIONS section for details on the recommended amounts of media.
LAVA MEDIA
Pour the lava granules or lava coals evenly into the burner area (see Fig. 15-1).
Important: DO NOT exceed a height of
1
/
2
" above the burner when placing lava media. Store any excess media in a safe location.
VOLCANIC STONE
1. Volcanic stones fi rst require lava granules to be placed as a base. See above LAVA MEDIA section to place the granules, then proceed to step 2.
2. Pour the volcanic stone evenly into the burner area (see
Fig. 15-2). The stones may form a mound. Store any
excess media in a safe location.
GLASS MEDIA
Pour the glass media (glass, gems, nuggets) evenly into the burner area (see Fig. 15-3).
Note: If desired, lava granules may fi rst be used as a base, followed by the glass.
Important: DO NOT exceed a height of
1
/
2
" above the burner when placing glass / lava media. Store any excess media in a safe location.
Fig. 15-1 Lava media option
Fig. 15-2 Volcanic stone option
Fig. 15-3 Glass option
Glass shown
15
OPTIONAL COVERS
OPTIONAL GFRC COVER
An optional GFRC cover is available to protect your unit when not in use. Contact your local dealer for ordering information.
To place the cover, allow the unit to cool completely, then place as shown in Fig. 16-1.
Note: Certain decorative media (such as volcanic stones, etc.) may interfere with the proper placement of the cover. They will need to be removed and stored in a safe location when the cover is in use.
OPTIONAL FABRIC COVER
An optional fabric cover is available to protect your unit when not in use. Contact your local dealer for ordering information.
To place, allow the unit to cool completely, then place the cover over the unit with the American Fyre Designs logo facing upward.
Follow all instructions provided with the fabric cover.
Note: Certain decorative media (such as volcanic stones, etc.) may interfere with the proper placement of the cover. They will need to be removed and stored in a safe location when the cover is in use.
Fig. 16-1 GFRC cover placement
16
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. BEFORE LIGHTING, smell all around the unit area for gas. Be sure to smell next to the fl oor, because some gas is heavier than air and will settle on the fl oor.
B. WHAT TO DO IF YOU SMELL GAS
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. If odor continues, immediately call your gas supplier or the fi re department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, DO NOT try to repair it. Call a qualifi ed professional service technician. Force or attempted repair may result in fi re or explosion.
1. STOP! Read the safety information above.
2. Ensure the gas control knob is in the OFF position before beginning lighting sequence.
3. Lay a lighted long-stem match on the surface of the decorative media near the burner (do not hold the
match in your hand) or use a lighted long-necked butane lighter (Fig. 17-1).
4. Once the match is burning and in position, depress the gas control knob and turn it counter-clockwise to the HI LIGHT position (see Fig. 17-2). Your burner should light.
CAUTION: If the burner does not light before the match goes out, immediately turn the control knob clockwise to the OFF position.
Wait approximately fi ve (5) minutes to clear out any gas, and repeat steps 1-4 above.
If your burner fails to light again, turn the control knob clockwise to the OFF position and contact your dealer or gas supplier.
TO SHUT OFF GAS TO THE APPLIANCE
To extinguish your gas burner, depress the gas control knob and turn it clockwise to the OFF position (see Fig.
17-2). Be sure the control knob is turned fully off to avoid any gas leakage.
Apply match - then turn on gas
Fig. 17-1
ON
(HI LIGHT)
Fig. 17-2
OFF
17
INSTRUCTIONS D'ALLUMAGE - MODÈLES DE BOUTONS DE CONTRÔLE
POUR VOTRE SÉCURITÉ, LIRE AVANT D'ALLUMER
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, UN INCENDIE OU UNE
EXPLOSION POURRAIENT S'ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,
DES BLESSURES OU DES PERTES DE VIE.
A. AVANT D'ALLUMER, sentez tout autour de l'unité de surface pour le gaz. Assurez-vous de sentir près du plancher, car certains gaz sont plus lourds que l'air et se déposent sur le sol.
B. QUE FAIRE SI UNE ODEUR DE GAZ
1. Coupez le gaz à l'appareil.
2. Éteindre toute fl amme nue.
3. Si l'odeur persiste, appelez immédiatement votre fournisseur de gaz ou le service des incendies.
C. N'utilisez que votre main pour enfoncer ou tourner le bouton de contrôle du gaz. Ne jamais utiliser d'outils.
Si le bouton ne sera pas enfoncer ou à tourner à la main, NE PAS essayer de le réparer. Appelez un technicien de service qualifi é. Force ou une tentative de réparation pourrait provoquer un incendie ou une explosion.
1. ARRÊT! Lire les consignes de sécurité ci-dessus.
2. S'assurer que le bouton de contrôle du gaz est en position OFF (éteindre) avant de séquence d'éclairage
à partir la position.
3. Posez une lumineuse à longue tige match sur la surface du support de décoration à proximité de l'anneau brûleur
(ne tenez pas le match en main) ou utiliser un briquet au butane allumée au long cou (Fig. 18-1).
4. Une fois que le match est en feu et en position,
appuyer sur le bouton de contrôle du gaz et tournez dans le sens antihoraire à la position de HI LIGHT
(allumer) (voir Fig. 18-2). Votre brûleur devrait s'allumer.
ATTENTION: Si le brûleur ne s'allume pas avant le match s'éteint, tournez immédiatement le bouton de réglage dans le sens horaire à la position OFF (éteindre).
Attendez environ cinq (5) minutes pour laisser
échapper tout le gaz, et répétez les étapes
1-4 ci-dessus.
Si votre brûleur ne s'allume pas, tournez le bouton de réglage dans le sens horaire à la position OFF (éteindre) et contactez votre revendeur ou fournisseur de gaz.
POUR ARRÊTER LE GAZ À L'APPAREIL
Pour éteindre le brûleur à gaz, appuyer sur le bouton de contrôle du gaz et tourner dans le sens horaire à la position
OFF (éteindre) (voir Fig. 18-2). Assurez-vous que le bouton de commande est tourné complètement hors tension pour
éviter toute fuite de gaz.
Appliquer match - puis tourner sur le gaz
Fig. 18-1
ALLUMER
(HI LIGHT)
Fig. 18-2
ÉTEINDRE
(OFF)
18
LIGHTING INSTRUCTIONS - KEY VALVE MODELS
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. BEFORE LIGHTING, smell all around the unit area for gas. Be sure to smell next to the fl oor, because some gas is heavier than air and will settle on the fl oor.
B. WHAT TO DO IF YOU SMELL GAS
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. If odor continues, immediately call your gas supplier or the fi re department.
C. Use only a proper key to turn the gas line valve. Never use tools. If the valve will not turn, DO NOT try to repair it. Call a qualifi ed professional service technician. Force or attempted repair may result in fi re or explosion.
1. STOP! Read the safety information above.
2. Ensure the key valve is completely in the OFF position before beginning lighting sequence.
3. Lay a lighted long-stem match on the surface of the decorative media near the burner (do not hold the
match in your hand) or use a lighted long-necked butane lighter (Fig. 19-1).
4. Once the match is burning and in position, slowly turn the key valve counter-clockwise toward the ON position until it no longer rotates (see Fig. 19-2). Your burner should light.
CAUTION: If the burner does not light before the match goes out, immediately turn the key valve clockwise toward the OFF position until it no longer rotates.
Wait approximately fi ve (5) minutes to clear out any gas, and repeat steps 1-4 above.
If your burner fails to light again, turn the key valve clockwise toward the OFF position until it no longer rotates and contact your dealer or gas supplier.
TO SHUT OFF GAS TO THE APPLIANCE
To extinguish your gas burner, insert the key into the key valve and turn the valve clockwise toward the OFF position until it no longer rotates (see Fig. 19-2). Be sure the control knob is turned fully off to avoid any gas leakage.
Apply match - then turn on gas
Fig. 19-1
ON
Key valve
Fig. 19-2
OFF
19
INSTRUCTIONS D'ALLUMAGE - MODÈLE DE VANNE CLÉ
POUR VOTRE SÉCURITÉ, LIRE AVANT D'ALLUMER
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, UN INCENDIE OU UNE
EXPLOSION POURRAIENT S'ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,
DES BLESSURES OU DES PERTES DE VIE.
A. AVANT D'ALLUMER, sentez tout autour de l'unité de surface pour le gaz. Assurez-vous de sentir près du plancher, car certains gaz sont plus lourds que l'air et se déposent sur le sol.
B. QUE FAIRE SI UNE ODEUR DE GAZ
1. Coupez le gaz à l'appareil.
2. Éteindre toute fl amme nue.
3. Si l'odeur persiste, appelez immédiatement votre fournisseur de gaz ou le service des incendies.
C. Utilisez uniquement une clé propre à tourner la vanne de la conduite de gaz. Ne jamais utiliser d'outils. Si la vanne ne tourne pas, NE PAS essayer de le réparer. Appelez un technicien de service qualifi é. Force ou une tentative de réparation pourrait provoquer un incendie ou une explosion.
1. ARRÊT! Lire les consignes de sécurité ci-dessus.
2. S'assurer que le robinet est complètement clé en position OFF (ÉTEINDRE) avant de séquence d'éclairage à partir.
3. Poser une allumettes à tige longue éclairé sur la surface des médias décoratifs près du brûleur (ne pas tenir le
match en main) ou utiliser un briquet au butane long cou éclairé (Fig. 20-1).
4. Une fois que le match est en feu et en position,
tourner lentement la vanne clé dans le sens antihoraire vers la position ON (allumer) jusqu'à ce qu'il ne tourne plus (voir Fig. 20-2). Votre brûleur devrait s'allumer.
ATTENTION: Si le brûleur ne s'allume pas avant le match s'éteint, tournez immédiatement le vanne clé dans le sens horaire vers la position OFF
(ÉTEINDRE)
jusqu'à ce qu'il ne tourne plus
Attendez environ cinq (5) minutes pour laisser échapper tout le gaz, et répétez les
étapes 1-4 ci-dessus.
Si votre graveur ne s'allume à nouveau, tourner le vanne clé dans le sens horaire vers la position OFF
(ÉTEINDRE)
jusqu'à ce qu'il ne tourne plus et contactez votre revendeur ou fournisseur de gaz.
POUR ARRÊTER LE GAZ À L'APPAREIL
Pour éteindre votre brûleur à gaz, insérez la clé dans la valve touche et tournez la valve dans le sens horaire vers la position d'arrêt jusqu'à ce qu'il ne tourne plus (voir Fig.
20-2). Assurez-vous que le bouton de commande est tourné
à fond au large pour éviter toute fuite de gaz.
Appliquer match - puis tourner sur le gaz
Fig. 20-1
ON
(ALLUMER)
vanne clé
Fig. 20-2
OFF
(ÉTEINDRE)
20
SERVICING AND CLEANING
Each installation site for any unit presents its own unique combustion environment. Specifi c factors such as weather, wind currents, yard debris, altitude, drafts, the size of the surrounding area, all have an infl uence on the proper operation of the unit. A normally operating unit will demonstrate the following characteristics:
• A lively, realistic yellow fl ame
• Odor-free
If the fl ame is not clean (identifi able by excessive sooting on the decorative media ), refer to the information below. Some soot on the media may occur and should not be a concern unless excessive.
• Cover your unit whenever it is not in use, and follow the guidelines below at least annually.
ANNUAL CLEAN / INSPECTION GUIDELINES
The unit and the installation must be inspected annually. Refer to these instructions for details. Performing these procedures will ensure proper operation, appearance, and safety. WEAR GLOVES.
If maintenance is required, it must be done by a qualifi ed professional service technician.
• Always shut off the gas to the unit while performing service work.
• Allow the unit to cool before servicing.
• The entire burner system should be inspected regularly:
Excessive debris can build up on this unit from leaves, dirt, or other debris. It is critical that all control components, burners, vent openings, and the surrounding area be kept clean and free of all obstructions.
Examine that all components are properly assembled / installed as instructed in this manual.
Ensure that all decorative media is properly placed as instructed in this manual.
damaged. Contact your local dealer for replacement parts.
• DO NOT use substitute materials when replacing any components of the appliance.
• Keep the vent openings and surrounding area of the of the unit clean and free of obstructions at all times.
combination of blue/yellow at the body and tips. Contact a qualifi ed service person for maintenance.
recommended. Allow to dry and follow up with a concrete sealer in order to preserve the fi nish. A.F.D. recommends
Miracle Sealants Tile & Stone Cleaner and 511 Porous Plus Sealer products to maintain the concrete.
appliance.
• Verify proper operation after servicing.
FUEL CONVERSION KITS
A certifi ed kit is available from the manufacturer to convert your appliance from natural gas to L.P. or vice versa. Contact your dealer for ordering information.
Follow the instructions provided with the kit when converting.
(your model and design may vary)
Keep surrounding area and vent openings clear for proper venting
Fig. 21-1
CAUTION: HOT DURING OPERATION AND AFTER USE. Children must be supervised when in the vicinity of this appliance. Serious injury may occur! Children must be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition.
21
NOTES PAGE
Please use this page to record any information that you may want to have at hand.
22
TROUBLESHOOTING
If you have trouble with your unit, please use this list to identify the problem. By trying one or more of the solutions to the probable cause, you should be able to solve the problem. If this list does not address your present problem, or if you have other technical diffi culties with your unit, please contact your local dealer or visit our web site at
www.rhpeterson.com.
SYMPTOM
Burner will not turn on
PROBABLE CAUSE CORRECTIVE ACTION
1. Gas not reaching appliance
2. Air in gas line
1. Check gas supply and gas shut-off valve.
2. Purge air from gas line.
Unit overheating or poor combustion
1. Vent openings / surrounding area blocked with debris
1. Clean vent openings and surrounding area of all obstructions.
Low fl ame
Low fl ame or too high fl ame
1. Low gas pressure 1. Check gas pressure (Read D-E of PRE-INSTALLATION
AND PREPARATION SAFETY GUIDELINES section, & check with local gas company).
2. Fill tank completely.
2. Propane tank running low
(if applicable)
1. Using natural-gas burner on propane gas or propane burner on natural gas
1. Ensure proper gas type. The gas supply used may not be the same as that stated on the unit rating plate. Shut down immediately to verify, and if necessary contact your local dealer. (The unit may be converted to the gas type of the gas supply, IF PERMITTED.)
Flame lifts off the burner assembly
1. Unit exposed to high-wind conditions
1. Ensure that the unit is installed in an area that is less susceptible to high wind conditions.
Flame height drops when unit is in operation
1. Low gas pressure (due to improper gas supply line)
1. Check gas supply line and gas pressure (Read D-E of
PRE-INSTALLATION AND PREPARATION SAFETY
GUIDELINES section, & check with local gas company).
Burner lights but will not stay lit
1. Low gas pressure 1. Check gas pressure (Read D-E of PRE-INSTALLATION
AND PREPARATION SAFETY GUIDELINES section, & check with local gas company).
2. Unit exposed to high-wind conditions
2. Ensure that the unit is installed in an area that is less susceptible to high wind conditions.
3. Clogged burner ports
4. Faulty valve or regulator
3. Clean burner ports.
4. Contact a qualifi ed professional service technician and the local dealer.
Burner fl ashback or fl ame burning out of orifi ce
1. Clogged burner ports
2. Clogged burner orifi ce
1. Clean burner ports.
2. Clean burner orifi ce.
23
WARRANTY
AMERICAN FYRE DESIGNS BY R. H. PETERSON CO.
LIMITED WARRANTY
Robert H. Peterson Co. (“RHP”) warrants your American Fire Designs product to be free from defects in material and workmanship.
American Fyre Designs (“AFD”) exterior fi replaces, BBQ islands, fi re tables, fi re urns, fi re pits, Fire Falls, Fire Walls, gas logs, and burner components (“products”) are warranted for THREE (3) YEARS.
All AFD valves, electrical components, and controls are warranted for ONE (1) YEAR (excluding batteries).
This warranty does not apply to: product used in sub-freezing weather or damage caused by high temperature and rapid cooling; damage caused by burning wood or any fuel other than natural gas or propane; or damage or discoloration to product used in high wind conditions.
A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE IS REQUIRED
This warranty applies to the original purchaser for products which are installed in the United States or Canada and which are operated and maintained as intended for single family residential usage. This warranty is valid only with proof of purchase, shall commence on the date of purchase, and shall terminate (both as to original and any replacement products) on the anniversary date of the original purchase of the product stated on the above schedules.
This warranty covers defects in material and workmanship. This warranty does not cover parts which become defective as a result of negligence, misuse, use not in compliance with the Owner’s Manual/Installation Instructions, accidental damage, improper handling, improper storage, improper installation, lack of required routine maintenance (as specifi ed in the Owner’s Manual/Installation Instructions), electrical damage, local gas impurities or failure to protect against combustibles. Product must be installed (and gas must be connected) as specifi ed in the Owner’s Manual/Installation Instructions by a qualifi ed professional installer. Modifi cations to products which are not specifi cally authorized will void this warranty. Accessories, parts, valves, remotes, etc. when used must be Peterson products or this warranty is void. Warrantied items will be repaired or replaced at Peterson’s sole discretion.
This warranty does not apply to rust, corrosion, oxidation, or discoloration unless the affected part becomes inoperable.
This warranty does not cover labor or labor related charges, except as provided by separate specifi c written programs from the Peterson Co. All repair work must be performed by a qualifi ed professional service person and requires prior approval of Peterson.
Peterson may require the defective product or part to be returned to the factory to determine the cause of failure. Peterson will pay freight charges if the product or part is determined to be defective. This warranty does not cover breakage in shipment from our (Independent) distributor to its customer if the damage is determined to have occurred during that shipment.
This warranty specifi cally excludes liability for indirect, incidental, or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specifi ed legal rights, and you may have other rights that vary from state to state or province.
For additional information regarding this warranty, or to place a warranty claim, contact the R. H. Peterson dealer where the product was purchased.
TO REGISTER YOUR PRODUCT ONLINE GO TO: WWW.RHPETERSON.COM,
AND CLICK ON PRODUCT REGISTRATION. THANK YOU FOR YOUR PURCHASE.
Quality Check Date:_________________
Burner Orifi ce Nat.
L.P.
Leak Test: ___________ Model#: ___________________
Main: ____ ____ Burn Test: ___________ Serial#: ___________________
Gas Type: Nat. / L.P. Inspector: ___________________
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
24
advertisement
Key Features
- For outdoor use only
- Adjustable flame height
- Carbon monoxide hazard warning
- Safety features: pressure relief valve, overfill prevention device
- Easy to assemble and install
- Multiple decorative media options
- Optional covers for protection when not in use
- Complies with national safety standards