Quick Reference Guide
CP-SP-1203E
Quick Reference Guide
This guide offers a summary of key operations, parameter flowcharts, and settings, for
convenient reference at the operation site. This guide is made for repeated use. Dirt wipes
off easily and even notes written with an oil-based felt-tip pen can be removed with an
eraser. If more detailed information on the SDC35/36 is needed, refer to the user's manual: CP-SP-1150E for installation and configuration.
The most convenient way to configure the SDC35/36 is with the Smart Loader Package
(model No. SLP-C35J50). Please contact the azbil Group or a distributor for more information.
Upper display
Lower display
Upper display
Indicator
during AT
Lower display
Various
indicators
Mode
indicator
Mode indicator
Multi-Status (MS) display
[mode] key
[display] key
[<], [ ], and [ ] keys
[display] key
[para] key
Loader connector
[<], [ ], and [ ] keys
<
[para] key
[mode] key
<
<
<
[enter] key
Loader connector
[enter] key
Lower display
This display shows either the SP/MV/CT or the display value and set value for each displayed
item. The decimal point at the right end digit shows the RUN/READY mode or communication
status.
Multi-Status (MS) display
Turns ON in READY mode or when an alarm occurs, depending on the ON conditions and the
current status. When lit, in addition to flashing and reciprocating between left and right, it performs MV graph, DI monitor, internal event monitor, and other display functions.
Mode indicators
man:
rsp:
ev1, ev2, ev3:
ot1, ot2:
[mode] key
• When this key is pressed and held for more than 1 second in the operation display mode,
any of the following operations from 0 to 7 which have been set previously can be executed
0 : Mode key does not operate (Initial value)
1 : AUTO/MANUAL mode selection
2 : RUN/READY mode selection
3 : AT (Auto Tuning) start/stop selection
4 : LSP (Local SP) group selection
5 : Release all DO (Digital Output) latches 6 : LSP/RSP mode selection
7 : ON/OFF selection of communication DI
• When pressing the [mode] key in the setup display mode, the display is changed to the operation display
[display] key
This key is used to change the display item in the operation display mode.
When pressing this key in the bank selection, bank setup, or user function setup display
mode, the display is changed ot the operation display.
[para] key
When this key is kept pressed for 2 sec. or longer in the operation display mode, the display is
then changed to the setup display.
[<], [ ], [ ] keys
These keys are used to increase or decrease the numeric value, or to shift the digit.
The [ ] and [ ] keys are used to change the bank or display item.
[enter] key
This key is used to begin changing settings (display goes from lit to flashing) and to finalize
new settings (display goes from flashing to steadily lit).
Loader connector
This connector is used for connecting to a personal computer using the dedicated cable supplied with the Smart Loader Package.
Lights when MANUAL (AUTO mode if not lit)
Lighs when RSP
Lights when event relays are ON
Lights when the control output is ON (always lit when the current output is
used)
<
<
<
This display shows either the PV value or the display value and set value for each displayed
item. If an alarm is triggered, the normal display and alarm code are displayed alternately.
During auto tuning (AT), the rightmost decimal point flashes twice repeatedly.
<
Upper display
1
Flowchart of key operations and displays
When the power
is turned ON
PV value
LSP group number
Step No.
PV value
SP value
Step remaining time
MV value
[display] key
Upper and lower displays
remain off for 5s after
power ON. Each mode
indicator lights sequentially,
and then the operation
display appears.
SP value
②
Timer remaining
time 3
Internal event 3
sub-setting
Internal event 3
main setting
Internal event 3
delay time
Setting value
Setting value
①
Timer remaining
time 2
[para] key
Internal event 2
delay time
2-second press
+ hold of
[para] key
[display] key
(3)
[para] key
or
[V] key
[Mode]
[SP]
[Event]
[display] key
2
[ ] key
[enter] key
[enter] key
While AUtO
is flashing,
[enter] key
2-second press
+ hold of
[para] key
[ ] key
V
(1)
to
V
User
function
(AUTO)
2-second press
+ hold of
[para] key
(MANUAL)
While MAn
is flashing,
[enter] key
to
1
to
(2)
(2)
[para] key
[para] key or
[V] key
2
[PID]
[Parameter] [Extended tuning]
[Zone]
O Some items are not displayed depending on the availability of optional functions, model number,
display setup (C73 to C78) and display level (C79).
O Pressing [display] while bank item or user function item is displayed has the effect of canceling
Operation displays
and returning to the operation display item.
PV value
CT1
Heat manipulated
variable
Cool manipulated
variable
MFB
MV value
MV value
MFB value
Internal event 2
sub-setting
Internal event 2
main setting
Timer remaining
time 1
Internal event 1
sub-setting
Internal event 1
main setting
CT2
Setting value
Setting value
Internal event 1
delay time
Setting value
Setting value
Current
value
[display] key
AT progress
value
Current value
Bank selection
[Event configuration] [DI assignment]
[Setup]
[DO assignment]
[User function]
[Lock]
[para] key
or
[V] key
[Instrument information]
[ ] key
V
[enter] key
Communications
Key operations and displays
SP
Continuous outputs
Control actions
Analog input
2-second
press +
hold of
[para] key
Notes:
(1) The parameters and numerical values registered as user functions UF
are displayed.
(2) In the RSP mode, RSP and PI D.r are displayed first.
Position proportional
■ Explanation of arrows
[display] key
:
[para] key
:
[enter] key
:
■ Movement through each setup menu
• [ ] key
V
SP
(3) If no key is pressed for 3 minutes, the display automatically returns
to 2 , PV display
• [para] key or [V] key
3
Operation examples
Red letters
Blue letters
Setup of PV input range type
2
AT forces ON/OFF of the MV a number of times (a limit
cycle) to calculate PID values.
Check that this operation does not create any problems
for the associated equipment before executing AT.
Press and hold
[para] for more than
2s to get the parameter setup display.
MOde flashes on the
upper display.
1
Press [display] once
to get the operation
display.
2
Press and hold
[para] for more than
2s to get the parameter setup display.
MOde flashes on the
upper display.
3
Press [enter] or [<]
to get A--M on the
upper display and
autO on the lower
display.
4
Press [ ] as needed until At and
at.Of appear on
the upper and
lower displays
respectively.
6
Press [ ] or [ ]
once, and at.Of
flashes on the
lower display.
If no sensor is connected,
an alarm for abnormal
PV input (any one from
AL0 1 to AL 1 1) may
appear on the upper
display.
Press [enter].
The current set value
for C0 1 (PV input
range type) is
displayed.
If the control method is
ON/OFF control and if
Bit 3 (AT stop/start
display) of the mode
display setting (C73) is
set to "disabled: 0,"
nothing is displayed.
<
The display flashes only
in RUN and AUTO modes,
and only if there is no PV
problem.
Also, if DI is set to "AT
stop/start", the display
does not flash and the
setting cannot be
changed.
Setup of event operation type
In this example, the event 1 operation type is set to
deviation high limit.
Press [ ] or [ ]
repeatedly to get
evCf flashing on the
upper display.
<
3
Press [display] once
to get the operation
display.
<
1
2
4
7
Press and hold
[para] for more than
2s to get the parameter setup display.
MOde flashes on the
upper display.
Setup of SP value
Press [enter] to get
e 1.c 1 on the upper
display and 0 is
displayed on the
lower display.
1
Press [display]
repeatedly so that
the orange SP
indicator lights up
on the lower display.
The operation
display now shows
the SP.
2
If [enter] is pressed,
the rightmost digit on
the lower display
flashes and numerical value can be
changed.
<
6
Press [enter], and
the displayed value
4 on the lower
display changes
from flashing to
continuously lit and
the displayed value
is set.
3
Press [<], [ ] or [ ]
to change to the
desired SP value.
The flashing of
the number indicates that the
setting has not yet
been finalized.
4
If [enter] is pressed,
the displayed value
is set and the
display changes
from flashing to
continuously lit.
4 on the lower display
indicates that the event
operation type is
set for deviation high limit.
<
<
When [enter] is
pressed, the rightmost digit on the
lower display flashes.
Press [ ] or [ ] to
get 4 flashing on the
display.
If [enter] is pressed, at.ON remains steadily lit and AT
begins.
During AT, the rightmost decimal point flashes twice
repeatedly.
(When AT is done, the light goes off and the new PID
values go into effect.)
During the AT process, if the mode is changed to READY or
MANUAL, if PV input is faulty, or if a power failure occurs, AT stops
automatically without changing the PID values.
AT can also be stopped by changing the setting from At.ON to At.OF
(return to step 4 above).
0 on the lower display
indicates that the event
operation type is set to
"none."
5
When [enter] is
pressed, at.Of
flashes on the
lower display.
<
5
<
<
4
Press [enter].
The rightmost digit on the lower display flashes and its
value can be changed.
Press [<], [ ] or [ ] to change to the desired sensor type
in the PV input range list.
Then press [enter] to finalize your selection.
(If the number is flashing, the [enter] key has not yet
been pressed, and the setting has not yet been saved.)
<
5
Press [ ] or [ ]
repeatedly, and
Stup flashes on the
upper display.
<
3
<
Press [display] once
to get the operation
display.
: Items during operation
Execution of auto tuning (AT)
<
1
: Items before operation
If an SP limit is in effect, the
numerical value cannot be
changed to a value above
the limit. The SP limit must
be changed first.
Similarly, use e2.C 1 to set the event 2 operation type, and
use e3.C 1 for event 3.
4
If the [display] key is
pressed without pressing
[enter] key, the status
returns to that of step 1.
• For step numbers indicated in red like 2 , the following precaution applies:
If the key lock is set, the numerical value does not flash, and the value cannot be changed.
To change a numerical value, cancel the key lock first.
AUTO/MANUAL mode selection
Press [display] once
to get the operation
display.
2
Press and hold
[para] for more
than 2s to get the
parameter setup
display. MOde
flashes on the
upper display.
4
Press [<], [ ] or [ ]
to change to the
desired MV value.
Even while the
number is flashing,
the MV is changed
at the same time
that the number is
changed.
3
Press [ ] twice or [ ]
repeatedly, and EV
flashes on the upper
display.
4
Press [enter] to get
e 1 on the upper
display and 0 is
displayed on the
lower display.
<
0 on the lower display
indicates that the event
main setting is "0".
For the flashing MV in step 3, either bumpless transition
(the same value as before the change) or preset MANUAL
value (the value set in setup C20) can be selected (in setup
C19, Output operation after AUTO-MANUAL change).
5
<
When control output is R1 (motor relay output) and setup
C57 is "0" (initial value) or "1", the following position proportional control auto adjust is necessary.
2
Press and hold
[para] for more
than 2s to get the
parameter setup
display. MOde
flashes on the
upper display.
7
<
<
Press [enter] to get
C0 1 on the upper
display.
Press [<], [ ] or [ ]
to change to C60.
(C60: position proportional control auto
adjust)
5 on the lower display
indicates that the event
hysteresis is "5".
<
6
<
If [enter] is pressed,
the lower display
flashes.
Press [ ] or [ ] to
get 1.
Press [enter] and
auto adjustment
starts.
8
In the same way
that event settings
were changed, press
[enter] to make the
number flash, and
then press [<], [ ]
or [ ] to change to
the desired setting
for hysteresis. After
that, press [enter]
to finalize the
setting.
Similarly, use E2.HY to set a value for event 2, and E3.HY
to set a value for event 3.
CA.CL is displayed on
the upper display and
open contact is ON.
The lower display
shows the MFB count
value and when count
is stable, CA.OP is
displayed on the
upper diplay and
closed contact is ON.
When the count value
is stable, auto adjust
completes to get
operation display.
After starting auto adjust, press [display] key to stop
auto adjust.
During auto adjust the key operation except [display] key
of stopping auto adjust is impossible.
5
If [enter] is pressed,
the changed
numerical value is
set and changes
from flashing to
continuously lit.
<
To continue from
this point and set
hysteresis as well,
press [ ] twice or
[ ] repeatedly to get
E 1.HY on the upper
display. The lower
display says 5.
<
4
<
Press [ ] or [ ] repeatedly until StUP
is flashing on the
upper display.
<
3
6
Similarly, use e2 to set a value for event 2, and e3 to set
a value for event 3.
<
Press [display] once
to get the operation
display.
If [enter] is pressed,
the rightmost digit
on the lower display
flashes, and can
be changed.
Press [<], [ ], or [ ],
and change to the
desired value for
event set value. In
this case, the flashing of the numerical
value implies that it
is not yet set.
<
Execution of position proportional control auto adjust
1
<
When Man appears,
stop pressing [mode].
The MV is shown
on the lower display.
The rightmost digit
of the MV on the
lower display flashes
and its value can
be changed.
1
If the control method is
set to "ON/OFF control"
and if the DI assignment
is "AUTO/MANUAL," the
display does not blink
and the setting cannot be
changed.
The [mode] key can be
used for 1 of 7 different
operations.
The initial (factory) setting
is "AUTO/MANUAL
selection".
3
In this example, the event set value and hysteresis for
the event 1 operation type is set to deviation high limit.
Press and hold
[mode] for more
than 2s, Man
flashes on the
lower display.
<
2
<
Press [display] once
to get the operation
display.
<
1
Setup of event value
5
List of parameter
: Essential parameters for PV measurement and control
: Basic parameters
: Required parameters when using optional functions
Et
List of operation displays
SP(Target value)
SP low limit to SP high limit
LSP group number
(1st digit=the right end digit)
Step operation remaining
time
1 to LSP system group (Max. 4)
Setting is disabled.
The step No. distinguishes up ramp,
down ramp, and soak.
MV (Manipulated Variable) -10.0 to +110.0%
Setting is enabled in MANUAL mode
(Numeric value flashed)
Heat MV (Manipulated Variable) Setting is disabled.
-10.0 to +110.0%
Cool MV (Manipulated Variable)
MFB (Motor opening feedback
value)
PV
At 1 (Display example)
Ct 1
Numeric value
Ct2
Numeric value
E1
Numeric value
E 1. Sb
Numeric value
t 1. --(Display example)
Numeric value
E2
Numeric value
E2. Sb
Numeric value
t2. --(Display example)
Numeric value
E3
Numeric value
E3. Sb
Numeric value
t3. --(Display example)
Numeric value
Contents
Setting is disabled.
+10.0 to +110.0%
Flashing when the value is 0.0 to 100.0% during estimate.
Setting is disabled.
Initial value Setting value
0
1
–
JF.Ov
–
ZOne
–
Display
ZO- 1 to ZO-7
ZOdf
–
–
AT progress display
(1st digit=the right end digit)
CT current value 1
Setting is disabled.
–
CT current value 2
Setting is disabled.
–
Internal Event 1 main setting
-1999 to +9999U or 0 to 9999U
0
StUP
Internal Event 1 sub setting
–
C 10
RSP input type
Internal Event 3 sub setting Same as Internal Event 1 sub setting
0
C11
C 12
C 14
RSP input range low limit
RSP input range high limit
Control action (Direct/Reverse)
Internal Event 3 remaining Same as Internal Event 1 remaining time
time
–
C 15
0
Contents
Initial value Setting value
AUTO: AUTO mode MAN: MANUAL mode
AUTO
RUN: RUN mode RDY: READY mode
RUN
lSp: LSP RSp: RSP
LSP
At. OF: AT stop At. ON: AT start
AT stop
Lt. ON: Latch continue Lt. OF: Latch release Latch continue
dI . OF: OFF dI . On: ON
OFF
Control
Setting value
Initial value
0
0
Setting value
5
C43
Derivative time (PID1 to 8)
Manual reset (PID1 to 8)
MV low limit (PID1 to 8)
MV high limit (PID1 to 8)
Proportional band (cool) (PID1 to 8)
Integral time (cool) (PID1 to 8)
Initial value
5.0
120
Setting value
30
50.0
0.0
100.0
5.0
120
30
0.0
100.0
[Parameter bank]
Display
CtrL
At. OL
At. OH
dI FF
OFFS
FL
rA
bI
fl2
ra2
bI2
CyU
Cy
CyU2
Cy2
tP.ty
●
outl
SPU
SPd
● Output variation limit
● SP up ramp
● SP down ramp
●
●
●
Item
Control method
MV low limit at AT
MV high limit at AT
Differential (for ON/OFF control)
ON/OFF control action point offset
PV filter
PV ratio
PV bias
RSP filter
RSP ratio
RSP bias
Time proportional cycle unit 1
Time proportional cycle 1
Time proportional cycle unit 2
Time proportional cycle 2
Time proportional cycle mode
Contents
Initial value
0: ON/OFF control 1: Fixed PID
0 or 1
-10.0 to +110.0%
0.0
-10.0 to +110.0%
100.0
0 to 9999U
5
-1999 to +9999U
0
0.0 to 120.0s
0.0
0.001 to 9.999
1.000
-1999 to +9999U
0
0.0 to 120.0s
0.0
0.001 to 9.999
1.000
-1999 to +9999U
0
0 to 3 *1
0
5 to 120s or 1 to 120s *2
10 or 2
0 to 3 *1
0
10 or 2
5 to 120s or 1 to 120s *2
0: Controllability aiming type
0 or 1
1: Operation end service life aiming type (Only ON/
OFF operation within Time proportional cycle)
0.0 to 999.9% (No limit when set at "0.0U")
0.0
0.0 to 999.9U (No ramp when set at "0.0U")
0.0
0.0
*1 0: Unit of "1s" 1: Fixed at 0.5s 2: Fixed at 0.2s 3: Fixed at 0.1s
*2 5 to 120s when output includes the relay output
Continuous output
d- 1 to d-8
Contents
0.1 to 999.9%
0 to 9999s or 0.0 to 999.9s
(No integration control action when set at "0")
0 to 9999s or 0.0 to 999.9s
(No derivative control action when set at "0")
-10.0 to +110.0%
-10.0 to +110.0%
-10.0 to +110.0%
0.1 to 999.9%
0 to 9999s or 0.0 to 999.9s
(No integration control action when set at "0")
0 to 9999s or 0.0 to 999.9s
(No derivative control action when set at "0")
-10.0 to +110.0%
-10.0 to +110.0%
Setting value
U: Unit Maximum unit of Industrial volume in PV range (°C, Pa,L/min, etc.)
Position proportional
Item
Proportional band (PID1 to 8)
Integral time (PID1 to 8)
C32
C33
C34
C35
C36
C37
C38
C39
C40
C4 1
C42
0
[PID bank]
d- 1C to d-8C Derivative time (cool) (PID1 to 8)
PV
Initial value
–
1
0
1
0
0
[Event bank]
OL. 1C to OL.8C Output low limit (cool) (PID1 to 8)
OH. 1C to OH.8C Output high limit (cool) (PID1 to 8)
SP MV Time proportional output
C26
C27
C28
C29
C30
C3 1
SP
Contents
Setting is disabled.
1 to 8
SP low limit to SP high limit
1 to 8
0 to 9999
0.0 to 999.9 or 0 to 9999
C 16
C 17
C 18
C 19
C20
C2 1
C22
C23
C24
[SP bank]
rE- 1 to rE-8
OL- 1 to OL-8
OH- 1 to OH-8
P- 1C to P-8C
I - 1C to I -8C
PARA
Item
PV input range type
Temperature unit
● Cold junction compensation
Decimal point position
PV input range low limit
PV input range high limit
SP low limit
SP high limit
● PV square root extraction dropout
0
Item
Contents
Internal Event 1 to 8 main setting -1999 to +9999 or 0 to 9999
Internal Event 1 to 8 sub setting (The decimal point position may vary so that it
meets the operation type of the internal event)
Internal Event 1 to 8 hysteresis 0 to 9999
E 1.Hy to E8.Hy
(The decimal point position may vary so that it
meets the operation type of the internal event)
E 1.On to E8.On ● Internal Event 1 to 8 ON delay time 0.0 to 999.9 or 0 to 9999
E 1.Of to E8.Of ● Internal Event 1 to 8 OFF delay time
Display
P- 1 to P-8
I - 1 to I -8
Setting value
0
Contents
-1999 to +9999U
0 to 9999
Initial value
9999U
5U
Setting value
Initial value
88
0
0
0
0
1000
0
1000
0.0
Setting value
[Setup bank]
Internal Event 2 remaining Same as Internal Event 1 remaining time
time
Internal Event 3 main setting Same as Internal Event 1 main setting
Display
E 1 to E8
E 1.Sb to E8.Sb
PI D
Display
C0 1
C02
C03
C04
C05
C06
C07
C08
C09
0
Communication
Ev
Item
● Zone 1 to 7
● Zone hysteresis
Internal Event 2 sub setting Same as Internal Event 1 sub setting
Item
RSP
PID group number (RSP)
SP of LSP 1 group to 8 group
PID group number (LSP 1 to 8)
Ramp (LSP1 to 8)
Time (LSP 1 to 8)
Initial value
1
0.30
0.0
1.00
1.00
1.00
0
[Zone bank]
–
Item
AUTO/MANUAL
RUN/READY
LSP/RSP
AT stop/start
Release all DO latches
Communication DI1
Display
RSP
PIDr
SP- 1 to SP-8
Pid. 1 to Pid.8
rMP. 1 to rMP.8
tI M. 1 to tI M.8
Contents
0: Normal 1: Immediate response 2: Stable *1
0.00 to 10.00
0.0 to 999.9
0.00 to 99.99
0.00 to 99.99
0.00 to 99.99
0: PID(Conventional PID)
1: Ra-PID(High-performance PID)
Just-FiTTER oversheet suppression factor 0 to 100
Internal Event 1 remaining Setting
is disabled.
L
time
" ", is displayed at the right end digit when using
the ON delay time, and "L" , the OFF delay time.
Internal Event 2 main setting Same as Internal Event 1 main setting
Key operation • display
SP
Item
AT type
Just-FiTTER setting band
SP lag constant
Proportional band tuning factor at AT
Integral time adjust at AT
AT Derivative time adjust
Control algorithm
List of setup setting displays
[Mode bank]
Display
A--M
r--r
l--r
At
do Lt
C. dI 1
●
●
●
●
●
–
List of parameter setting displays
MOdE
[Extended tuning bank]
*1 Normal = Standard control characteristics, Immediate response = Control characteristics that respond immediately to external disturbance, Stable = Control characteristics having less up/down fluctuation of PV
Analog input
HEAt
Numeric value
COOL
Numeric value
fb
Numeric value
Item
Control action
Display
Upper display: PV
Lower display: SP
PV
SP
LSP 1 (Display example)
LSP
St 1-(Display example)
Step No.
Step remaining time
PV
MV
Display
At.ty
JF.bd
SP.LG
At-P
At-I
At-d
Ctr.A
6
C44
C45
C46
C47
C48
C49
C50
C5 1
C52
C53
C54
C55
C56
C57
C58
C59
C60
C6 1
C62
C63
C64
C65
C66
C67
C68
C69
C70
C7 1
C72
C73
C74
Contents
For details, refer to the PV Input Range Table
0: Celsius (°C) 1: Fahrenheit (°F)
0: Performed (internal) 1: Not performed (external)
0: No decimal point 1 to 3: 1 to 3 digits below decimal point
When the PV input type is DC voltage/DC current,
-1999 to +9999U
PV input range low limit to PV input range
high limit
0.0 to 100.0% (PV square root extraction
is not performed when set at "0.0".)
0: 4 to 20mA 1: 0 to 20mA 2: 0 to 5V
3: 1 to 5V 4: 0 to 10V
-1999 to +9999U
0
0
1000
0
0: Heat control (Reverse action)
1: Cool control (Direct action)
0
● Output operation at PV alarm 0: Control calculation is continued.
1: Output at PV alarm is output.
● Output at PV alarm
-10.0 to +110.0%
0.0
Output at READY (Heat)
-10.0 to +110.0%
0.0
Output at READY (Cool)
-10.0 to +110.0%
0.0
Output operation at changing AUTO/MANUAL 0: Bumpless transfer 1: Preset
0
Preset MANUAL value
-10.0 to +110.0%
0.0 or 50.0
● Initial output type of PID control
0: Auto 1: Not initialized 2: Initialized
0
● Initial output of PID control
-10.0 to +110.0%
0.0 or 50.0
● PID decimal point position
0: No decimal point
0
(decimal point of integral time and delivative time) 1: 1 digit after decimal point
● Zone PID operation
0: Disabled 1: Changed by SP
0
2: Changed by PV
Heat/Cool control
0: Not used 1: Used
0
Heat/Cool selection
0: Normal 1: Energy saving
0
Heat/Cool control dead zone -100.0 to +100.0%
0.0
● Heat/Cool control change point -10.0 to +110.0%
50.0
LSP system group
1 to 8
1
0
● SP ramp type
0: Standard 1: Multi-ram 2: Step operation
When the power is turned ON again, the
step operation is stopped (READY)
3: Step operation When the power is turned
ON again, the step operation is reset
● SP ramp unit
0: 0.1U/s 1: 0.1U/min 2: 0.1U/h
1
● STEP time unit
0: 0.1s 1: 1s 2: 1min
0
● STEP PV start
0: Disabled 1: Enabled
0
● STEP loop
0: Stop 1: Loop 2: Final step continued
0
CT1 operation type
0: Heater burnout detection 1: Current value measurement
0
CT1 output
0 to 1: Control output 1 to 2, 2 to 4: Event output 1 to 3
0
CT1 measurement wait time 30 to 300ms
30
CT2 operation type
Same as CT1
0
CT2 output
Same as CT1
0
CT2 measurement wait time Same as CT1
30
Current output 1: 4 to 20mA 2: 0 to 20mA
1
Control output 1 range
Continuous voltage output 1: 1 to 5V 2: 0 to 5V 3: 0 to 10V
Control output 1 type
0: MV 1: Heat MV 2: Cool MV 3: PV
0
4: Ratio, bias, and PV before filter 5: SP
6: Deviation 7: CT1 current value
8: CT2 current value 9: Invalid 10: SP+MV
11: PV+MV
Control output 1 scaling low limit -1999 to +9999U
0.0
Control output 1 scaling high limit
100.0
Control output 1 MV scaling
0 to 9999 (Valid when control output 1 type is 10 or 11)
200
Control output 2 range
Same as control output 1
1
Control output 2 type
Same as control output 1
3
Control output 2 scaling low limit Same as control output 1
0
Control output 2 scaling high limit Same as control output 1
1000
Control output 2 MV scaling
Same as control output 1
200
Auxiliary output range
Same as control output 1
1
Auxiliary type
Same as control output 1
3
Auxiliary output scaling low limit Same as control output 1
0
Auxiliary output scaling high limit Same as control output 1
1000
Auxiliary output MV scaling
Same as control output 1
200
Position proportional type
0: MFB control + Estimated position control
0
1: MFB control
2: Estimated position control (MFB disabled)
3: Estimated position control (MFB disabled)
+ Position adjustment at power ON.
Position proportional dead zone 0.5 to 25.0%
10.0
Motor long life mode
0: Aiming at controllability
1
1: Aiming at service life of potentiometer
Motor auto adjust
0: Stop 1: Start
0
Input with motor fully closed 0 to 9999
1000
Input with motor fully open
0 to 9999
3000
Motor full close-full open time 5.0 to 240.0s
30.0
CPL/MODBUS
0: CPL 1: MODBUS (ASCII format)
0
2: MODBUS (RTU format)
Station address
0 to 127 (Communication is disabled when set at "0".)
0
Transmission speed (bps)
0: 4800 1: 9600 2: 19200 3: 38400
2
Data format (Data length)
0: 7 bits 1: 8 bits
1
Data format (Parity)
0: Even parity 1: Odd parity 2: No parity
0
Data format (Stop bit)
0: 1 bit 1: 2 bits
0
● Response time-out
1 to 250ms
3
● Key operation type
0: Standard type 1: Special type
0
[mode] key function
0: Invalid 1: AUTO/MANUAL selection
1
2: RUN/READY selection 3: AT Stop/Start
4: LSP group selection 5: Release all DO latches
6: Invalid 7: Communication DI1 selection 8: Invalid
MODE display setup
Bit 0: AUTO/MANUAL display (Enabled: +1)
255
Bit 1: RUN/READY display (Enabled: +2)
(Sum of the weighting)
Bit 2: LSP/RSP display (Enabled: +4)
Bit 3: AT Stop/Start display (Enabled: +8)
Bit 4: Release all DO latches display (Enabled: +16)
Bit 5: Communication DI1 ON/OFF display (Enabled: +32)
Other invalid setting, 0, +64, +128
PV/SP display setup
Bit 0: PV display (Enabled: +1)
15
(Sum of the weighting)
Bit 1: SP display (Enabled: +2)
Bit 2: LSP group number display (Enabled: +4)
Other invalid setting, 0, +8
• Items marked ● in the tables are displayed in standard and/or high function configuration.
Item
MV display setup
(Sum of the weighting)
C76
EV display setup
(Operation display)
C77
Timer remain time display setup
(Operation display)
C78
CT display setup
(Operation display)
User level
C79
Key operation • display
C81
C82
● Communication monitor
display
● MS display, Condition
(top priority)
● MS display, Status
(top priority)
C87
C88
● MS display, Condition
(secondary priority)
● MS display, Status
(secondary priority)
● MS display, Condition
(third priority)
● MS display, Status
(third priority)
● MS display, Deviation range
● Special function
C89
● Zener barrier adjustment
C90
C9 1
C92
C93
●
●
●
●
C83
C84
C85
C86
EvCF
Number of CT1 turns
Number of CT1 power wire loops
Number of CT2 turns
Number of CT2 power wire loops
Item
Internal event 1 to 8 Configuration 1
Operation type
E 1.C2 to E8.C2
Internal event 1 to 8 Configuration 2
Operation type
1st digit: Direct/Reverse
2nd digit: Standby
3rd digit: EVENT state at READY
4th digit: Undefined
E 1.C3 to E8.C3 ● Internal event 1 to 8 Configuration 3
1st digit: Controller alarm OR
2nd digit: Special OFF setup
3rd digit: Delay unit
4th digit: Undefined
Display
di 1. 1 to dI 5. 1
6
Display
UF- 1 to UF-8
Same as MS display, Condition (top
priority)
Same as MS display, Status (top priority)
1
LOC
9
0 to 9999U
0 to 15 (This value becomes "0" when the
power is turned ON.)
The value can be changed with the adjustment
The numeric value cannot be directly
input with the manual operation.
0: 800 turns 1 to 40: CT turns divided by 100
0: 1 time 1 to 6: Number of times
0: 800 turns 1 to 40: CT turns divided by 100
0: 1 time 1 to 6: Number of times
5
0
Display
LOC
Setting value
Precaution for setup
· The type of auto tuning can be changed by changing the value of At.ty (AT
type) in the extended tuning bank. Set it to match the control characteristics.
· Be sure the motor is adjusted: C60 (motor auto adjust: start) in the setup bank.
· The result of AT control on a position proportioning model is that derivative
time (D) = 0. If satisfactory control cannot be obtained, set At-d (AT derivative time adjust, in the extended tuning bank) to 1.00.
0
0
dO
0
Contents
Refer to event type (see page 8)
The digits are determined to 1st, 2nd, 3rd,
and 4th digit from the right end.
0: Direct 1: Reverse
0: None 1: Standby 2: Standby + Standby at SP change
0: Continue 1: Forced OFF
0
The digits are determined to 1st, 2nd, 3rd,
and 4th digit from the right end.
0: None 1: Alarm direct + OR operation
2: Alarm direct + AND operation
3: Alarm reverse + OR operation
4: Alarm reverse + AND operation
0: As usual
1: When the event set value (main setting)
is 0, the event is "OFF".
0: 0.1s 1: 1s 2: 1min
0
0
Ot 1.3 to Ot2.3 ●
Ev 1.3 to Ev3.3
39
Ot 1.4 to Ot2.4 ●
Ev 1.4 to Ev3.4
Ot 1.5 to Ot2.5 ●
Ev 1.5 to Ev3.5
Ot 1.6 to Ot2.6 ●
Ev 1.6 to Ev3.6
1
Ot 1.7 to Ot2.7 ●
Ev 1.7 to Ev3.7
Ot 1.8 to Ot2.8 ●
Ev 1.8 to Ev3.8
UF
44
Initial value Setting value
0
dI 1.3 to dI 5.3 ● Internal contact 1 to 5
Input assign A
0
0
0
0
0
0
0
Initial value Setting value
–
Item
Key lock
Id
Contents
Initial value Setting value
0: All settings are possible
0
1: Mode, event, operation display, SP, UF, lock,
manual MV can be set
2: Operation display, SP, UF, lock,
manual MV can be set
3: UF, lock, manual MV can be set
0: read/write enabled 1: read/write disabled
0
0: read/write enabled 1: read/write disabled
0
0 to 15(5: Password 1A to 2B display)
0
0000 to FFFF (Hexadecimal value)
0000
0000 to FFFF (Hexadecimal value)
0000
0000 to FFFF (Hexadecimal value)
0000
0000 to FFFF (Hexadecimal value)
0000
[Instrument information bank]
I d08
Item
ROM ID
ROM Version 1
ROM Version 2
Loader information
EST information
Manufacturing date code
(year)
● Manufacturing date code
(month, day)
● Serial No.
●
●
●
●
●
●
Contents
2: Fixed
XX. XX (2 digits after decimal point)
XX. XX (2 digits after decimal point)
Subtract 2000 from the year.
Example: "3" means the year 2003.
Month + day divided by 100.
Example: "12.01" means the 1st day of December.
Initial value Setting value
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
0
Changing the user level
0
0
Initial value Setting value
0
This controller's user level can be set to 1 of 3 types in setup C79.
The number of possible displays and settings decreases
according to the user level: high function > standard > simple. All items are displayed when high function is selected.
1
If necessary, press
[mode] once to
change to the
operation display.
Next, press and
hold [para] for more
than 2 seconds to
get the parameter
setup display. MOde
flashes on the upper
display.
2
Press [ ] or [ ]
repeatedly as needed to get STUP
flashing on the
upper display.
3
Press [enter].
C0 1 is shown on the
upper display.
Press [<], [ ] or [ ]
to change to C79
(user level).
4
When [enter] is
pressed, the lower
display flashes.
Press [ ] or [ ] to
change to the desired
setting, and press
[enter] to finalize
your selection.
0
2: Contact 1
3: Contact 2
4: Contact 3
5: Contact 4
0
0
0
0
0
0
0
0
0
<
0: Direct 1: Reverse
0: Every Internal Event
1 to 8: Internal Event No.
Contents
–
<
dI 1.4 to dI 5.4 ● Internal contact 1 to 5
Input assign B
dI 1.5 to dI 5.5 ● Internal contact 1 to 5
Input assign C
dI 1.6 to dI 5.6 ● Internal contact 1 to 5
Input assign D
dI 1.7 to dI 5.7 ● Internal contact 1 to 5
Polarity A to D
1st digit: Polarity A
2nd digit: Polarity B
3rd digit: Polarity C
4th digit: Polarity D
dI 1.8 to dI 5.8 ● Internal contact 1 to 5 Polarity
dI 1.9 to dI 5.9 ● Internal contact 1 to 5
Event channel def.
Item
● User function 1 to 8
● Communication lock
● Loader lock
Password display
Password 1A
Password 2A
Password 1B
Password 2B
I d07
0
0
[Lock bank]
Display
I d0 1
I d02
I d03
I d04
I d05
I d06
0
0
0
0
14: Output 1
15: Output 2
2: Event 1
3: Event 2
4: Event 3
0
[User function bank]
C.LOC
L.LOC
PASS
PS 1A
PS2A
PS 1b
PS2b
8
1
8
1
Initial value Setting value
0
<
dI 1.2 to dI 5.2 ● Internal contact 1 to 5
Input bit function
Contents
0: No function 1: LSP group selection (0/+1)
2: LSP group selection (0/+2)
3: LSP group selection (0/+4)
4: PID group selection (0/+1)
5: PID group selection (0/+2)
6: PID group selection (0/+4)
7: RUN/READY selection
8: AUTO/MANUAL selection
9: LSP/RSP selection 10: AT Stop/Start
11: Invalid 12: Control action direct/reverse
13: SP Ramp enabled/disabled
14: PV Hold 15: PV Maximum value hold
16: PV Minimum value hold 17: Timer Stop/Start
18: Release all DO latches (Continue/Release)
19: Advance 20: Invalid
0: Not used (Default input)
1: Function 1 ((A and B) or (C and D))
2: Function 2 ((A or B) and (C or D))
3: Function 3 (A or B or C or D)
4: Function 4 (A and B and C and D)
0: Normally opened 1: Normally closed
2 to 5: DI1 to 4 6 to 9: Undefined
10 to 17: Internal Event 1 to 8
18 to 21: Communication DI1 to 4
22: MANUAL 23: READY 24: RSP
25: AT running 26: During SP ramp 27: Undefined
28: Alarm occurs 29: PV alarm occurs
30: Undefined 31: mode key pressing status
32: Event output 1 status
33: Control output 1 status
The digits are determined to 1st, 2nd, 3rd
and 4th digit from the right end.
0: Direct 1: Reverse
Contents
0: Default output 1 to 2: MV1 to 2
3 to 6: Function 1 to 4
0: Normally opened 1: Normally closed
2 to 9: Internal Event 1 to 8
10 to 13: Undefined 14 to 15: MV1 to 2
16 to 17: Undefined 18 to 21: DI1 to 4
22 to 25: Undefined
Output assign B (Control output 1 to 2, 26 to 30: Internal Contact 1 to 5
Event output 1 to 3)
31 to 33: Undefined 34 to 37: DI1 to 4
38: MANUAL 39: READY 40: RSP
Output assign C (Control output 1 to 2, 41: AT running 42: During SP ramp 43: Undefined
Event output 1 to 3)
44: Alarm occurs 45: PV alarm occurs
46: Undefined 47: Mode key pressing status
Output assign D (Control output 1 to 2, 48: Event output 1 status
Event output 1 to 3)
49: Control output 1 status
Control output 1 to 2, Event output The digits are determined to 1st, 2nd, 3rd,
1to 3 Polarity A to D
and 4 th digit from the right end.
1st digit: Polarity A
0: Direct 1: Reverse
2nd digit: Polarity B
3rd digit: Polarity C
4th digit: Polarity D
Polarity (Control output 1 to 2, 0: Direct 1: Reverse
Event output 1 to 3)
Latch (Control output 1 to 2, 0: None 1: Latch (Latch at ON)
Event output 1 to 3)
2: Latch (Latch at OFF except for initialization
at power ON)
0.00
[DI assignment bank]
Item
Internal contact 1 to 5
Operation type
[DO assignment bank]
Display
Item
Ot 1. 1 to Ot2. 1 ● Operation type (Control output 1 to 2,
Ev 1. 1 to Ev3. 1
Event output 1 to 3)
Ot 1.2 to Ot2.2 ● Output assign A (Control output 1 to 2,
Ev 1.2 to Ev3.2
Event output 1 to 3)
1
[Event configuration bank]
Display
E 1.C 1 to E8.C 1
di
Initial value
15
<
C80
Contents
Bit 0: MV display (Enabled: +1)
Bit 1: Heat MV/cool MV display (Enabled: +2)
Bit 2: MFB display (Enabled: +4)
Bit 3: AT progress display (Enabled: +8)
0: Not displayed
1: Set value of Internal event 1 is displayed
2: Set values of Internal event 1 to 2 are displayed
3: Set values of Internal event 1 to 3 are displayed
0: Not displayed
1: Internal event 1 is displayed
2: Internal event 1 to 2 is displayed
3: Internal event 1 to 3 is displayed
0: Not displayed 1: CT1 current value is displayed
2: CT1 to 2 current values are displayed
0: Simple configuration 1: Standard configuration
2: High function configuration
0: Not used
1: Flashing while data is sending through
RS-485 communication
2: Flashing while data is receiving through
RS-485 communication
3: Logical OR of all DI statuses
4: Flashing in READY mode
0: Normally OFF 1: Normally ON
2 to 9: Internal event 1 to 8
10 to 13: Undefined 14: MV1 15: MV2
16 to 17: Undefined 18 to 21: DI1 to 4
22 to 25: Undefined
26 to 30: Internal contact 1 to 5
31 to 33: Undefined
34 to 37: Communication DI 1 to 4
38: MANUAL 39: READY 40: RSP
41: AT 42: During ramp 43: Undefined
44: Alarm 45: PV alarm 46: Undefined
47: [mode] key pressing status
48: Event output 1 terminal status
49: Control output 1 terminal status
0: lit 1: Slow flashing 2: Flashing twice
3: Fast flashing 4: Left to right
5: Right to left
6: Reciprocating between left and right
7: Deviation OK 8: Deviation graph
9: MV graph 10: Heat-side MV graph
11: Cool-side MV graph 12: MFB graph
13: DI monitor 14: Internal contact monitor
15: Internal event monitor
Same as MS display, Condition (top
priority)
Same as MS display, Status (top priority)
<
Display
C75
in the lower right part of this page.
Changing the user level
<
• To change a user level, refer to
0: Simple configuration
1: Standard configuration
(initial value)
2: High function configuration
7
PV input range table
[Thermocouple]
[RTD]
C01
Set value
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Sensor
type
K
K
K
K
K
K
K
J
J
J
J
E
E
T
R
S
B
N
PL II
WRe5-26
WRe5-26
Ni-Ni•Mo
PR40-20
DIN U
DIN L
Gold iron
chromel
Range
-200 to +1200°C
0 to 1200°C
0.0 to 800.0°C
0.0 to 600.0°C
0.0 to 400.0°C
-200.0 to +400.0°C
-200.0 to +200.0°C
0 to 1200°C
0.0 to 800.0°C
0.0 to 600.0°C
-200.0 to +400.0°C
0.0 to 800.0°C
0.0 to 600.0°C
-200.0 to +400.0°C
0 to 1600°C
0 to 1600°C
0 to 1800°C
0 to 1300°C
0 to 1300°C
0 to 1400°C
0 to 2300°C
0 to 1300°C
0 to 1900°C
-200.0 to +400.0°C
-100.0 to +800.0°C
0.0K to 360.0K
[DC voltage/DC current]
C01
Sensor
Range
Set value
type
81
0 to 10mV
Scaling range is
82
-10 to +10mV -1999 to +9999.
83
0 to 100mV
84
0 to 1V
86
1 to 5V
87
0 to 5V
88
0 to 10V
89
0 to 20mA
90
4 to 20mA
C01
Set value
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Sensor
type
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Event type
Operation
type
Set
value
Range
-200.0 to +500.0°C
-200.0 to +500.0°C
-200.0 to +200.0°C
-200.0 to +200.0°C
-100.0 to +300.0°C
-100.0 to +300.0°C
-100.0 to +200.0°C
-100.0 to +200.0°C
-100.0 to +150.0°C
-100.0 to +150.0°C
-50.0 to +200.0°C
-50.0 to +200.0°C
-50.0 to +100.0°C
-50.0 to +100.0°C
-60.0 to +40.0°C
-60.0 to +40.0°C
-40.0 to +60.0°C
-40.0 to +60.0°C
-10.00 to +60.00°C
-10.00 to +60.00°C
0.0 to 100.0°C
0.0 to 100.0°C
0.0 to 200.0°C
0.0 to 200.0°C
0.0 to 300.0°C
0.0 to 300.0°C
0.0 to 500.0°C
0.0 to 500.0°C
: Initial value
*1: If the ROM version 1 of the instrument
information bank (I d02) is prior to
2.04, a setting of "3" for the PV input
range type (C0 1) will result in display of
the K thermocouple 0 to 800°C range
with no decimal point.
*2: The indicated low limit for a B thermocouple is 20°C. However, if ROM version 1 of the instrument information
bank (I d02) is prior to 2.04, the value
is -180°C.
No event
PV high
limit
0
1
AL02
AL03
Input failure
AL05
AL06
AL07
Motor adjustment
failure
AL 1 1
CT input failure
(Over-range)
(CT input 1 or 2,
or both)
AL95
AL96
AL97
AL98
AL99
Cause
Sensor burnout, incorrect
wiring, incorrect PV input
type setting
PV input failure
Sensor burnout, incorrect
(Under-range)
wiring, incorrect PV input
type setting
CJ failure
Terminal temperature is
faulty (thermocouple).
PV input failure
Sensor burnout, incorrect
(RTD)
wiring
RSP input failure Sensor burnout, incorrect
(Over-range)
wiring, incorrect RSP
(Displayed in RSP mode) input type setting
RSP input failure Sensor burnout, incorrect
(Under-range)
wiring, incorrect RSP
(Displayed in RSP mode) input type setting
MFB input failure Burnout, incorrect wiring
AL 10
AL70
Instrument failure
Failure name
PV input failure
(Over-range)
A/D conversion
failure
Parameter failure
Burnout, incorrect wiring,
Power for motor is shutdown.
A current exceeding the
upper limit of the display
range was measured.
The number of CT turns
or the number of CT power
wire loops is incorrectly
set, or wiring is incorrect.
A/D converter is faulty.
Power is shut-down while
the data is being set, or
data is corrupted by noise.
Adjustment data
Power is shut-down while
failure
the data is being set, or
data is corrupted by noise.
Parameter failure Data is corrupted by
(RAM area)
noise.
Adjustment data
Data is corrupted by
failure (RAM area) noise.
ROM failure
ROM (memory) is faulty.
Reverse action
● shows that the ON/OFF is changed at this value.
O shows that the ON/OFF is changed at a point that
"1U" is added to this value.
Always OFF
Always OFF
HYS
ON
ON
Main setting
PV
PV low
limit
2
ON
HYS
HYS
Main setting
PV high/
low limit
3
ON
ON
Sub-setting *
HYS
Corrective action
HYS
PV
ON
ON
Check the ambient
temperature.
Check the wiring.
Check the wiring.
Set the RSP input type
again.
Check the wiring.
Set the RSP input type
again.
Check the wiring.
Check the MFB input value.
Check the wiring.
Adjust the motor again after
checking the power for motor.
• Use a CT with the
correct number of turns
for the display range.
• Reset the number of CT
turns.
• Reset the number of CT
power wire loops.
• Check the wiring.
Replace the unit.
HYS
SP + Main setting PV
5
ON
Deviation
high/low
limit
6
Deviation
high limit
(Final SP
reference)
Deviation
low limit
(Final SP
reference)
Deviation
high/low
limit
(Final SP
reference)
Heater 1
burnout/
Overcurrent
7
Heater 2
burnout/
Overcurrent
HYS
ON
4
HYS
HYS
SP + Main setting
Heater 1
shortcircuit
PV
Main setting * Sub-setting * PV
SP + Main setting PV
Deviation
low limit
ON
Main setting
PV
HYS
HYS
Main setting *
Deviation
high limit
PV
ON
HYS
HYS
ON
HYS
Main setting Sub-setting
PV
SP
HYS
ON
SP + Main setting
PV
PV
HYS
ON
Main setting Sub-setting
SP
PV
ON
ON
HYS
SP + Main setting PV
SP + Main setting PV
8
ON
HYS
HYS
SP + Main setting
ON
SP + Main setting
PV
PV
9
ON
HYS
HYS
ON
HYS
Main setting Sub-setting
PV
SP
ON
HYS
Main setting Sub-setting
SP
PV
16
ON
HYS
HYS
ON
HYS
Main setting *
Sub-setting *
CT1 at output ON
OFF before measuring the CT1 current value
ON
Main setting *
HYS
Sub-setting *
CT1 at output ON
OFF before measuring CT1 current value
17
HYS
ON
ON
Main setting
CT1 at output OFF
HYS
Main setting
CT1 at output OFF
OFF before measuring CT1 current value
Check the wiring.
Set the PV input type
again.
HYS
Main setting
List of alarm code
Alarm
code
AL0 1
Direct action
● shows that the ON/OFF is changed at this value.
O shows that the ON/OFF is changed at a point that
"1U" is added to this value.
OFF before measuring CT1 current value
18
ON
HYS
HYS
ON
HYS
19
Alarm
(status)
High and
low limits
of MFB
value
23
HYS
OFF before measuirng CT2 current value
ON
ON
Main setting
CT2 at output OFF
OFF before measuring CT2 current value
ON
HYS
HYS
Main setting *
HYS
Main setting
CT2 at output OFF
OFF before measuring CT2 current value
ON if alarm occurs (alarm code AL01 to 99).
OFF in other cases.
33
Sub-setting *
CT2 at output ON
OFF before measuring CT2 current value
Heater 2
shortcircuit
HYS
ON
Main setting *
Main setitng * Sub-setting *
CT2 at output ON
OFF if alarm occurs (alarm code AL01 to 99).
ON in other cases.
HYS
ON
Sub-setting *
MFB
ON
Main setting *
HYS
Sub-setitng *
MFB
: initial value
*: If the main setting is greater than the sub-setting, operations are performed with the main
setting and sub-setting automatically swapped.
Event types other than the above:
Operation type
SP high limit
SP low limit
SP high/low limit
MV high limit
MV low limit
MV high/low limit
Set value
10
11
12
13
14
15
Operation type
Loop diagnosis 1
Loop diagnosis 2
Loop diagnosis 3
READY (status)
MANUAL (status)
RSP (status)
• Restart the unit.
• Set the data again (set
data for AL95/97 and
adjustment data for
AL96/98.
• Replace the unit.
Handling precautions
• Reset the unit.
• Replace the unit.
1-12-2 Kawana, Fujisawa
Kanagawa 251-8522 Japan
Set value
20
21
22
24
25
26
Operation type
Set value
During AT (status)
27
During SP ramp
28
Control action (status)
29
ST setting standby (status)
30
Estimated position contorol (status)
31
Timer (status)
32
• If ROM version 1 of the instrument information bank (I d02) is prior to 2.04, "33"
cannot be set as [Internal Event configuration 1 operation type].
Specifications are subject to change without notice. (09)
Handling precautions
URL: http://www.azbil.com
• If ROM version 1 of the instrument information bank (I d02) is prior to 2.04, CT
input failure (AL 1 1) is not displayed.
8
1st edition: Dec. 2007 (W)
2nd edition: Apr. 2012 (M)
Was this manual useful for you? yes no
Thank you for your participation!