ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 2 o of 12 SolarLake e 10000TL Pow wer Quality. Harmonics. Gen nerating Unitt rating per p phase (rpp) Harm monic Att 45‐55% of rrated outputt Measured Vaalue (MV) % in Amps L1 2 L2 L3 L1 3 L2 L3 L1 4 L2 L3 L1 5 L2 L3 L1 6 L2 L3 L1 7 L2 L3 L1 8 L2 L3 L1 9 L2 L3 L1 10 L2 L3 0.035 0.045 0.023 0.032 0.012 0.031 0.037 0.024 0.036 0.118 0.120 0.113 0.020 0.016 0.012 0.076 0.074 0.072 0.019 0.018 0.012 0.040 0.043 0.010 0.008 0.010 0.013 3.33 kVA 100% off rated outpu ut Measure ed Value (M MV) % in Amps 0.141 0.184 0.095 0.131 0.049 0.125 0.148 0.097 0.146 0.478 0.486 0.457 0.081 0.066 0.047 0.310 0.300 0.291 0.076 0.073 0.049 0.161 0.174 0.041 0.032 0.039 0.052 0.030 0 0.039 9 0.029 9 0.030 0 0.020 0 0.027 7 0.054 4 0.057 7 0.062 2 0.085 5 0.093 3 0.070 0 0.012 2 0.011 1 0.001 1 0.069 9 0.077 7 0.065 5 0.005 5 0.006 6 0.001 1 0.038 8 0.047 7 0.010 0 0.005 5 0.004 4 0.003 3 Harmonic % = Measured V Value(Amps) * *23/rating per phase e(kVA) Lim it in BS EN 61 1000‐3‐12 1 phhase 3 phase 0.1 120 0.1 157 8% 8% 21.6% Not stated d 4% 4% 10.7% 10.7% 2.67% 2.67% 7.2% 7.2% 2% 2% 3.8% Not stated d 1.6% 1.6% 0.1 118 0.1 122 0.0 080 0.1 108 0.2 220 0.2 233 0.2 252 0.3 345 0.3 379 0.2 286 0.0 048 0.0 044 0.0 004 0.2 279 0.3 311 0.2 262 0.0 018 0.0 024 0.0 006 0.1 155 0.1 192 0.0 041 0.0 018 0.0 015 0.0 010 ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D L1 11 L2 L3 L1 12 L2 L3 L1 13 L2 L3 L1 THD D L2 L3 L1 PWH HD L2 L3 0.031 0.017 0.023 0.006 0.003 0.009 0.025 0.028 0.027 ‐ ‐ ‐ ‐ ‐ ‐ 0.127 0.068 0.094 0.024 0.012 0.036 0.103 0.114 0.111 1.62 1.80 1.82 4.52 4.86 4.90 TR 10005 0.052 2 0.052 2 0.056 6 0.004 4 0.003 3 0.001 1 0.043 3 0.043 3 0.026 6 ‐ ‐ ‐ ‐ ‐ ‐ Page 3 o of 12 0.2 210 0.2 212 3.1% 3.1% 1.33% 1.33% 2% 2% 23% 13% 23% 22% 0.2 229 0.0 016 0.0 013 0.0 003 0.1 175 0.1 173 0.1 107 1.25 1.3 39 1.5 52 2.8 89 3.24 3.17 ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 4 o of 12 SolarLake e 17000TL Pow wer Quality. Harmonics. Gen nerating Unitt rating per p phase (rpp) Harm monic Att 45‐55% of rrated outputt Measured Vaalue (MV) % in Amps L1 2 L2 L3 L1 3 L2 L3 L1 4 L2 L3 L1 5 L2 L3 L1 6 L2 L3 L1 7 L2 L3 L1 8 L2 L3 L1 9 L2 L3 L1 10 L2 L3 0.002 0.013 0.015 0.025 0.013 0.028 0.031 0.035 0.038 0.047 0.058 0.042 0.012 0.011 0.001 0.068 0.066 0.066 0.013 0.015 0.011 0.038 0.042 0.011 0.008 0.012 0.006 5.67 kVA 100% off rated outpu ut Measure ed Value (M MV) % in Amps 0.018 0.052 0.037 0.110 0.058 0.082 0.118 0.099 0.109 0.190 0.207 0.165 0.047 0.048 0.040 0.277 0.251 0.252 0.044 0.114 0.077 0.148 0.193 0.051 0.056 0.047 0.059 0.030 0 0.037 7 0.012 2 0.013 3 0.012 2 0.013 3 0.018 8 0.031 1 0.027 7 0.143 3 0.144 4 0.140 0 0.020 0 0.016 6 0.004 4 0.131 1 0.148 8 0.154 4 0.004 4 0.019 9 0.016 6 0.049 9 0.061 1 0.014 4 0.014 4 0.013 3 0.009 9 Harmonic % = Measured V Value(Amps) * *23/rating per phase e(kVA) Lim it in BS EN 61 1000‐3‐12 1 phhase 0.1 122 0.1 150 0.0 049 0.0 053 0.0 049 0.0 053 0.0 073 0.1 126 0.1 110 0.5 580 0.5 584 0.5 568 0.0 081 0.0 065 0.0 016 0.5 531 0.6 600 0.6 625 0.0 016 0.0 077 0.0 065 0.1 199 0.2 247 0.0 057 0.0 057 0.0 053 0.0 037 3 phase 8% 8% 21.6% Not stated d 4% 4% 10.7% 10.7% 2.67% 2.67% 7.2% 7.2% 2% 2% 3.8% Not stated d 1.6% 1.6% ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 5o of 12 L1 11 L2 L3 L1 12 L2 L3 L1 13 L2 L3 L1 THD D L2 L3 L1 PWH HD L2 L3 0.029 0.039 0.035 0.004 0.001 0.003 0.032 0.029 0.028 ‐ ‐ ‐ ‐ ‐ ‐ 0.117 0.162 0.152 0.017 0.007 0.013 0.134 0.105 0.093 1.23 1.32 1.12 4.60 4.80 4.82 0.084 4 0.092 2 0.081 1 0.005 5 0.005 5 0.001 1 0.061 1 0.065 5 0.055 5 ‐ ‐ ‐ ‐ ‐ ‐ 0.3 341 0.3 373 0.3 329 0.0 020 0.0 020 0.0 004 0.2 247 0.2 264 0.2 223 0.7 74 0.7 79 0.9 91 2.26 2.5 50 2.5 51 3.1% 3.1% 1.33% 1.33% 2% 2% 23% 13% 23% 22% ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 6 o of 12 Sol arLake 1700 00TL Pow wer Quality. V Voltage fluctuations andd Flicker. Starting Stopping g dmax dc [%] d(t) [%] [% %] 0.6 0.6 0.6 Normalised to ndard imped dance stan and 3.68kW for multiple units N/A N/A Limiits set unde er BS EN 661000‐3‐2 4% Running [%] d(t) [%] P st Plt 2 hours 0.5 5 0.5 0.5 0 .53 0.5 50 N/A N//A N/A N/A N N/A N/A A 3.3% 3.3% % 4% 3.3% 3.3% 11.0 0.6 65 5500ms 500ms dmaxx dc [%] Meaasured Value es Testt start date Testt location Test end date 06\05\20114 Eurofins Product Testing Servvice (Shanghai)Co.,Ltd. 06\05\2014 Sol arLake 1000 00TL Pow wer Quality. DC injection. Testt power leve el 10% % L1 55% L2 L3 L1 100% L2 L3 L11 L2 L3 L Reco orded value 0.035 0.0388 0.016 0.035 0.034 0.011 0.0333 0.037 0.014 0 as % % of rated AC C current 0.21 0.23 0.1 0..21 0.21 0.06 0.200 0.23 0.08 0 Limiit 0.25% % 0.25% 0.25% 55% 100% Sol arLake 1700 00TL Pow wer Quality. DC injection. Testt power leve el 10% % L1 L2 L3 L1 L2 L3 L11 L2 L3 L Reco orded value 0.062 0.0611 0.012 0.051 0.048 0.012 0.0556 0.055 0.010 0 as % % of rated AC C current 0.24 0.24 0.04 0..20 0.19 0.04 0.222 0.22 0.04 0 Limiit 0.25% % 0.25% 0.25% ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 7 o of 12 Sol arLake 1000 00TL Pow wer Quality. Power facto or. 216.2V 230V 253V Meaasured value e 0.999 0.999 0.999 Limiit >0.95 >0.95 >0.95 Measurred at threee voltage le evels and at full outputt. Voltage to o be maintained withinn ±1.5% of the stated llevel during the test. Sol arLake 1700 00TL Pow wer Quality. Power facto or. 216.2V 230V 253V Meaasured value e 0.999 0.999 0.999 Limiit >0.95 >0.95 >0.95 Measurred at threee voltage le evels and at full outputt. Voltage to o be maintained withinn ±1.5% of the stated llevel during the test. ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 8 o of 12 Prottection. Freq quency tests Funcction Settingg Trip te est “No ttrip tests” Fre equency Time delay F requency Time delay Frequency/TTime Confirrm no trip p U/F stage 1 4 47.5Hz 20s 47.49 Hz 21.06s 47.7Hz/ 25s No Trip U/F stage 2 47Hz 0.5s 46.99 Hz 0.546 s 47.2Hz/ 19.998s No Trip 46.8Hz/ 0.488s No Trip O/F stage 1 5 51.5Hz 90s 51.51 Hz 90.02 s 51.3Hz/ 95s No Trip O/F stage 2 52Hz 0.5s 52.01 Hz 0.529 s 51.8Hz/ 89.998s No Trip 52.2Hz/0.48ss No Trip Prottection. Volttage tests L1 Funcction Setting Trip tesst Vo oltage Time e delay “No ttrip tests” Vooltage Tim me delay Voltage /Time V e Confirm m no trip U/V stage 1 20 00.1 V 2.5s 2 2000.9 V 2.56 s 204.1V/ 3.5s 2 No trip U/V stage 2 184 V 0.5s 0 1884.9 V 0.55 s 188V/ 2.48s No trip 180V/ 0.48s No trip O/V V stage 1 26 62.2 V 1.0s 1 2660.3 V 1.096 s 1 258.2V/ 2.0s 2 No trip O/V V stage 2 27 73.7 V 0.5s 0 2773.5 V 0.569 s 0 269.7V/ 0.98s 2 s No trip 277.7V/ 0.48s 2 s No trip L2 Funcction Se etting Trip test Vo oltage Time e delay “N No trip Fun nction t ests” Vooltage Tim me delay Setting Trip te est Voltage /Time V e Confirm m no trip U/V stage 1 20 00.1 V 2.5s 2 2000.1 V 2.55 s 204.1V/ 3.5s 2 No trip U/V stage 2 184 V 0.5s 0 1884.8 V 0.55 s 188V/ 2.48s No trip 180V/ 0.48s No trip O/V V stage 1 26 62.2 V 1.0s 1 2559.5 V 1.097s 1 258.2V/ 2.0s 2 No trip O/V V stage 2 27 73.7 V 0.5s 0 2773.0 V 0.576 s 0 269.7V/ 0.98s 2 s No trip 277.7V/ 0.48s 2 s No trip L3 ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 9 o of 12 Funcction Se etting Trip test Vo oltage Time e delay “N No trip Fun nction t ests” Vooltage Tim me delay Setting Trip te est Voltage /Time V e Confirm m no trip U/V stage 1 20 00.1 V 2.5s 2 2000.8 V 2.54 s 204.1V/ 3.5s 2 No trip U/V stage 2 184 V 0.5s 0 1884.3 V 0.56 s 188V/ 2.48s No trip 180V/ 0.48s No trip O/V V stage 1 26 62.2 V 1.0s 1 2660.1 V 1.087s 1 258.2V/ 2.0s 2 No trip O/V V stage 2 27 73.7 V 0.5s 0 2773.3 V 0.574 s 0 269.7V/ 0.98s 2 s No trip 277.7V/ 0.48s 2 s No trip Notee for Voltage e tests the V Voltage requ ired to trip iis the setting g ±3.45V. Th e time delayy can be m measured att a larger de eviation thann the minim mum required d to operatee the protection. The No trip testts need to be carried ou b ut at the se etting ±4V an nd for the reelevant time es as wn in the table above to o ensure thatt the protecttion will nott trip in errorr. show ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 10 o of 12 Prottection. Losss of Mains te est accordingg BS EN 6211 16 Frequ uency : 50+/‐‐0.1 Hz UN = 230+/‐3 V Vac Testt conditions Distortion n factor of ch hokes < 2% Quality = 1 Discconnection limit 0.5 s Reactiv PAC e load (% of (% of QL nomi in 6.1.d) nal) QACC (% oof nom mi nal ) No.. PEUT(% of EUT rating 1 100 100 0 0 90 89 8 4 100 100 ‐5 ‐5 81 5 100 100 ‐5 0 6 100 100 ‐5 7 100 100 8 100 9 Run on Time (m ms) PEUT (W) Qff Remarks 91 10000 1 0.999 Test A a at BL 80 8 82 10100 1 1.002 Test A a at IB 78 76 7 79 10100 1 0.999 Test A a at IB +5 90 88 8 87 10070 1 0.997 Test A a at IB 0 ‐5 70 71 7 72 10100 1 1.002 Test A a at IB 100 0 +5 78 76 7 79 10100 1 0.998 Test A a at IB 100 100 +5 ‐5 55 56 5 58 10120 1 1.002 Test A a at IB 10 100 100 +5 0 90 88 8 86 10110 1 0.999 Test A a at IB 11 100 100 +5 +5 70 71 7 72 10100 1 0.997 Test A a at IB 12 66 66 0 ‐5 78 77 7 76 6620 1.003 Test B a at IB 13 66 66 0 ‐4 81 80 8 82 6620 1.002 Test B a at IB 14 66 66 0 ‐3 96 94 9 96 6620 1.002 Test B a at IB 15 66 66 0 ‐2 140 14 41 142 6620 1.001 Test B a at IB 16 66 66 0 ‐1 112 11 10 113 6620 1.001 Test B a at IB 2 66 66 0 0 172 17 73 170 6620 1 Test B a at BL 17 66 66 0 +1 108 10 06 109 6610 0.998 Test B a at IB 18 66 66 0 +2 99 96 9 98 6600 0.998 Test B a at IB 19 66 66 0 +3 108 10 09 106 6630 0.997 Test B a at IB 20 66 66 0 +44 117 11 16 115 6600 0.997 Test B a at IB 21 66 66 0 +5 89 88 8 86 6620 0.996 Test B a at IB 22 33 33 0 ‐5 115 11 12 113 3350 1.00 Test C a at IB 23 33 33 0 ‐4 50 51 5 52 3350 1.00 Test C a at IB 24 33 33 0 ‐3 99 98 9 96 3350 1.00 Test C a at IB 25 33 33 0 ‐2 101 10 02 100 3330 1.001 Test C a at IB 26 33 33 0 ‐1 130 13 31 132 3350 1.001 Test C a at IB 3 33 33 0 0 129 12 27 126 3350 1.002 Test C a at BL 27 33 33 0 +1 112 11 11 110 3350 1.002 Test C a at IB 28 33 33 0 +2 130 13 32 136 3360 1.003 Test C a at IB ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 11 o of 12 29 33 33 0 +33 123 12 25 126 3350 1.003 Test C a at IB 30 33 33 0 +44 121 12 22 124 3346 1.004 Test C a at IB 31 33 33 0 +55 151 15 53 154 3350 1.004 Test C a at IB Prottection. Freq quency change, Stability y test Start Frequeency Change End d Fre equency Confirm no o trip Positive Vector SShift 49.5Hz +9 de egrees No trip Negaative Vector Shift 50.5Hz ‐9 de egrees No trip Positive Frequen ncy Drift 49.5Hz +0.19 9Hz/sec 51.5Hz No trip Negaative Frequency Drift 50.5Hz ‐0.19 9Hz/sec 47.5Hz No trip Prottection. Re‐cconnection ttimer. Testt should pro ove that the e reconnectiion sequencce starts after a minimuum delay of 20 seco onds for restoration of vo oltage and frrequency to within the sttage 1 settin gs of table 1 1. Timee delay Measured setting elay de 330 s 36 s Checks onn no reconn nection whe en voltage oor frequenccy is brought too just outside stage 1 lim mits of table 1. At 266.2 V Confirmation that the No re‐connnect G does not rre‐connect. SSEG At 19 96.1 V No re‐connect At 47.4 Hz A At 51.6 Hz No o re‐connect No re‐connect ENG GINEERING R RECOMMEN NDATION G5 59/3 CER RTIFICATE & SAFETY – R R&D TR 10005 Page 12 o of 12 Faullt level contrribution. SollarLake 1000 00TL Sola arLake 170000TL Forr a Inverter SSSEG For a Inverter SSSEG Time After Fault Volts Ampps Time e After Fault Volts Amp ps 20m ms 23.06 0.994 20ms 23.07 0.96 6 100m ms 23.05 0.993 100m ms 23.06 0.96 6 250m ms 23.05 0.993 250m ms 23.05 0.95 5 500m ms 23.04 0.992 500m ms 23.05 0.93 3 Timee to trip 0.022 In secoonds Time e to trip 0.023 In seco onds ‐ Ennd of Document ‐
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement