Airwell | GC 43 | User manual | Product advantages

Add to my manuals
74 Pages

advertisement

Airwell | GC 43 | User manual | Product advantages | Manualzz

a i r w e l l . c o m

2007

ver) rsion (see o

GE TION & CHAUFFA

LOGUE MONDE TA

EL RI ST DU IN / E IR IA RT TE / L IE NT DE SI RÉ

CA

CLIMATISA

English ve

R E S I D E N T I A L / T E R T I A R Y / I N D U S T R I A L

CATALOGUE WORLD 2007

AIR CONDITIONING & HEATING

Version française (voir au dos)

m co l.

el rw ai

THE POWER OF A GROUP,

THE STRENGTH OF A NETWORK

s ope.

oduits e.

triel.

e servic e de l’Eur est ommercialisation ope et dans le monde.

ésidentiel, tertiaire et indus es plus pointues des marchés. Cela d’hui une large gamme de pr venant ainsi un des acteur e et dans le r s r

’innovation, la qualité et l lopper, de ve

’industrialisation et la c xigences l majeurs de la climatisation en Eur essé de se dé onception, l ell propose aujour eader de la climatisation en Franc implique un engagement total entièrement dédié à l

éseau Airwell n’a c t engagé depuis toujours dans la c répondant aux besoins des secteur loppement, Airw tant déve e r ell devient un l

En cons de systèmes de climatisation adaptés aux e

Depuis cette date, l

Airwell es

Fondé en 1947, Airw

Founded in 1947, Airwell is becoming a leader in air conditioning in France and in the rest of Europe.

Since its creation, the Airwell network has continually expanded to be ranked as one of the major players in air conditioning across Europe, and worldwide.

Airwell has always been involved in designing, manufacturing and marketing air conditioning systems adapted the market's most demanding requirements. This entails total commitment, dedicated entirely to innovation, quality and service.

As part of its continuous product development programme, Airwell currently offers a broad range of products to meet the specific requirement of all market sectors.

LA FORCE D’UN RÉSEAU

LA PUISSANCE D’UN GROUPE,

5 PRODUCTION SITES WORLDWIDE,

IN PERFECT SYNERGY

With highly efficient manufacturing resources benefiting from state-of-the-art manufacturing techniques, the group has 5 manufacturing plants worldwide with a total production capacity of 2,000,000 units. Our research & development and manufacturing systems are designed around each site's production specialisation.

Tillières (France)

Manufacture of industrial appliances for world markets. Aeraulics, thermodynamics and fluid mechanics R & D Centre.

Surface area: 110,000 m 2 .

Annual production:

180,000 units.

Dong-Guan (China)

Production and R & D Centre for electronic components at Group level.

Surface area: 15,000 m 2 .

Annual production:

5 million items (PCB, RC, IAQ…).

Shenzhen (China)

Production of low capacity residential and semi-industrial appliances.

Surface area: 100,000 m 2 .

Annual production:

1,000,000 units.

Barlassina (Italy)

Manufacture of large capacity air conditioning and chilled water production appliances up to 1,000 kW as well as convector fans.

Surface area: 50,000 m 2 .

Annual production: 30,000 units.

Pons (France)

Manufacture of medium capacity chilled water production appliances, chilled water terminals, convector fan and air treatment units

Surface area: 55,000 m 2 .

Annual production:

72,000 units.

1

2

SUMMARY

General information

p.6

COMFORT

RANGE

Wall mounted

RELAX

_ _ _ _ _ _ _ _ _ _ _ _ _ _ 2,1 to 5,1 kW

SIMPLY

_ _ _ _ _ _ _ _ _ _ _ _ _ 2,5 to 6,5 kW

FLORIDA

_ _ _ _ _ _ _ _ _ _ _ _ 8,5

XLS

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2,6 to 3,4 kW

2,15 to 5,5 kW

2,7 to 7,9 kW

9,5 kW

2,1 to 3,8 kW

Floor ceiling

SX

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2,6 to 8,8 kW 2,7 to 8,4 kW

S

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 10,1 to 13,0 kW 11,0 to 13,9 kW

SX SP

_ _ _ _ _ _ _ _ _ _ _ _ _ _ 1,8 to 5,5 kW

SX TELECOM

_ _ _ _ _ _ _ _ 5,2 to 8,4 kW

CCE

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 15 kW

Monoblocs

AELY

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2,9 to 3,5 kW

MAY

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2,1 to 6,4 kW

VAR

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2,5 kW

CAO

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2,3 to 4,7 kW

4,6 kW

5,5 kW

Cassettes

KLV/KXL

_ _ _ _ _ _ _ _ _ _ _ _ 2,6 to 12,5 kW 2,9 to 14,2 kW

MD

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9,1 to 12,6 kW 9,1 to 14,5 kW

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 16

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 18

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 20

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 22

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 24

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 26

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 28

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 30

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 31

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 32

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 33

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 34

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 36

COMFORT

RANGE

(...)

Ducted

BS

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3,4 to 12,6 kW 3,4 to 14 kW

DHC

_ _ _ _ _ _ _ _ _ _ _ _ _ 13,4 to 15,8 kW 13,8 to 16,2 kW

Multisplits

DUO/TRIO

_ _ _ _ _ _ _ _ _ 4,2 to 7 kW 4,4 to 11,4 kW

INDUSTRIAL

RANGE

Vertical cabinet units

XAR

_ _ _ _ _ _ _ _ _ _ _ _ _ _ 9,7 to 55 kW

XAO

_ _ _ _ _ _ _ _ _ _ _ _ _ _ 8,3 to 45,7 kW

Packaged Split System

DK/DN

_ _ _ _ _ _ _ _ _ _ _ 12 to 83 kW 12,4 to 83,8 kW

Rooftop

HA

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 10,1 to 27,9 kW 10,4 to 28,5 kW

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 38

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 40

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 42

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 46

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 48

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 50

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 52

3

4

CHILLED WATER

&

HEAT PUMP

RANGE

Fan-convectors

AQU@FAN 2 Tubes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1,1 to 13,9 kW

AQU@FAN 4 Tubes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1,1 to 14 kW

AQU@NET REGULATION

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Cassettes

KOG 2 TUBES & 4 TUBES

_ _ _ _ _ _ _ _ _ _ 2,2 to 10,6 kW

Ducted/Wall mounted

VHF OG

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3,3 to 11,9 kW

XLM OG

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1,8 to 4,6 kW

Air/water chillers

MQL/MQH

_ _ _ _ _ _ _ _ _ _ _ 4,5 to 16,5 kW 5 to 18,8 kW

Aqu@logic

AQL/AQH

_ _ _ _ _ _ _ _ _ _ _ 21,5 to 75 kW 24 to 87,4 kW

Air/water heat pump

CWP

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7,6 to 33,7 kW 9 to 40,1 kW

ACCESSORIES

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 56

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 58

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 60

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 62

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 64

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 65

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 66

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 68

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 70

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ p. 72

AIRWELL

IN ONE CLIC !

airwell.com

Discover very soon our new web site for Export !

CO

OLING ONLY

HE

AT PUMP

R407C Fluid R410A Fluid R22 Fluid

All AIRWELL products bear the CE mark

GENERAL NOTES: All values are specified for a 230 V supply voltage.

Nominal cooling capacity: International conditions: 27°C/19°C (wet bulb) - outside air temperature 35°C/24°C

(wet bulb) (Standards NF EN 255.2 - NF EN 814.2).

Nominal heating capacity: International conditions: 20°C/12°C (wet bulb) - outside air temperature 7°C/6°C (wet bulb)

(Standards NF EN 255.2 - NF EN 814.2).

Acoustic levels: Global acoustic pressure in dB(A) (1m comfort range, 4 m industrial and chilled water) under nominal conditions: outdoor unit in an open area against a reflective background - indoor unit: installation in an average sized room (PV - 0.5 s reverberation) or acoustic capacity depending on models.

CHILLED WATER

1) Water chillers

Nominal cooling capacity: watez inlet / outlet: 12°C / 7°C - outside air temperature: 35°C.

2) Terminal units

Nominal conditions: air 27°C / 19°C wet bulb (nominal air flow) - Chilled water: 7°C / 12°C

The fuse values and the between-unit (Split-System) link cable specifications are stated for basic units without accessories.

5

6

AIRWELL TECHNOLOGY

Indoor unit

“I FEEL” FUNCTION

transfers the point of temperature measurement to the place where the remote control is located and this offers better control of the desired temperature.

AIR FLAPS

automatically adopt the best blowing angle in relation to the mode selected.

Easily removable panel, washable with water.

TERMINAL BLOCK

Being particularly accessible, the terminal block makes connecting the mains power cable and interconnecting the indoor and outdoor units very easy.

Outdoor unit

ENTIRE GC

structure made of thermo-stable polyester material: noise levels and weight reductions, and increased service life. Anti-corrosion treatment with High Density powder paint coating ensuring high resistance to all operating conditions.

CONDENSER

The hydrophilic “bluefin” treatment encourages condensates drainage and protects against corrosion whilst guaranteeing performance and extending service life.

OPEN GC

DC INVERTER high efficiency rotary compressor. Increased acoustic insulation.

Tangential turbine

TURBINE

The aerodynamically designed tangential turbine with its increased diameter compared to the standard model, improves heat exchange and reduces noise levels.

MOTOR-FAN

DC Inverter variable capacity.

High efficiency.

Silent operation

Increased service life.

VALVES COVER

Improvement in condensing group's aesthetics and protection for the connecting valves.

SCREW

Reduced noise level, 3 aerodynamic blades, silent operation, improved heat exchange, better balance.

MULTI-FUNCTIONS REMOTE CONTROLS at the forefront of ergonomic design

> RCW2 model

BASIC FUNCTIONS

Compatible with products from the Comfort and Industrial ranges.

Heating / Cooling electronic regulation.

Automatic ventilation or 3 fixed speeds ventilation.

Night time slow running.

Dehumidification.

PROGRAMMING

Managing up to 15 zones (32 units) with individual unit time programming and temperature setting.

7 day programmable timer with 2 daily setting ranges.

2 TIMERS CENTRALISED CONTROL

Easy functions duplication for quick programming.

“Master/Slave” function.

Time delayed start up of air treatment units (quick installation).

Permanent “I feel” function (single installation).

>

RC4 model

>

RC5 model

With their compact and ergonomically design, Airwell infrared controls offer excellent user comfort. Combining modern design with high technology, the remote controls, with a range of up to 8 m, offer a host of functions and great simplicity of use to make our users' day-to-day life so much easier.

With these remote controls, users can select the operating mode (Heating-Cooling-Dehumidification), choose the set temperature point, ventilation speeds or air sweeping and also programme a host of advanced functions such as:

PROGRAMMING

The microprocessor automatically manages air conditioning for maximum user comfort. The Timer enables the unit to be programmed to switch itself on and off as and when required, thereby contributing to optimal energy consumption.

NIGHT RUNNING

This function adapts the temperature for ideal night time rest conditions for the user and contributes to energy savings.

Both in Heating and in Cooling mode it is possible to programme

3 set temperatures automatically. Energy consumption reductions amount to 7 % per degree, representing considerable savings.

Leaving home:

Programming and putting the unit on standby.

Programmed unit start-up.

Returning home:

Ambient temperature at desired level.

“I FEEL” FUNCTION

This innovation from the Airwell R&D department enables the temperature measurement point to be transferred for improved temperature control.

7

8

AIRWELL,

TECHNOLOGY

IN HARMONY WITH

THE ENVIRONMENT

ECOLOGICALLY FRIENDLY REFRIGERANT FLUIDS

Airwell's primary objective is to design and offer air conditioning systems that meet both the highest standards of environmental protection and users' legitimate expectations in terms of comfort and wellbeing.

For Airwell, innovation has to be linked tightly to a respect for the environment and must include stringent requirements in terms of quality levels. This ongoing concern governs all our actions and involves all our human and technology resources.

In accordance with this principle and with European Directives, in its appliances,

Airwell uses ecological refrigerant fluids of the HFC type (R410A & R407C) that do not harm the planet's ozone layer. (see R410A & R407C catalogue 2006)

Moreover, with a constant care for participating in preserving the environment,

Airwell designs and markets high efficiency products that reduce CO

2 emissions into the atmosphere and minimise our contribution to global warming.

ENERGY LABEL

Indication of annual energy consumption

Based on a standard model, this annual consumption is calculated by multiplying the total capacity by an average running time of 500 hours per annum in Cooling mode and under full load.

COOLING CAPACITY

The refrigerating capacity is defined as the cooling capacity in kW of an appliance, running in Cooling mode under full load.

EER OR ENERGY EFFICIENCY RATIO

This is the ratio between the refrigerating capacity and the amount of electricity consumed to attain it. In other words, the higher the EER, the better the energy efficiency.

ENERGY EFFICIENCY CATEGORIES*

IN COOLING MODE

A EER

B 3.2

>

3.2

>

EER

>

3.0

C 3.0

D 2.8

E 2.6

F 2.4

G 2.2

>

EER

>

2.8

>

EER

>

2.6

>

EER

>

2.4

>

EER

>

2.2

>

EER

* Only for splits and multisplits.

HEATING CAPACITY

Heating capacity is defined as the Heating capacity in kW of an appliance running in Heating mode and under full load.

COP OR COEFFICIENT OF PERFORMANCE

This is the ratio between the Heating capacity and the quantity of electricity consumed to attain it. In other words, the higher the COP, the better the energy efficiency.

ENERGY EFFICIENCY CATEGORIES*

IN HEATING MODE

A

B 3.6

C 3.4

D 3.2

COP

>

3.6

>

COP

>

3.4

>

COP

>

3.2

>

COP

>

2.8

E 2.8

F 2.6

G 2.4

>

COP

>

2.6

>

COP

>

2.4

>

COP

* Only for splits and multisplits.

Energy

Manufacturer

Outside unit

Unside unit

More efficient

A

B

C

D

E

F

G

Less efficient

Annual energy consumption kWh in cooling mode

(Actual consumption will depend on how the appliance is used and climate)

Cooling output

Energy efficiency ratio

Ful load (the higher the better) kW

Type Cooling only

Cooling + Heating

Air cooled

Water cooled

Heat output kW

Heating performance

A: higher

Noise

(dB(A) re 1 pW)

G: lower

Further information is contained in product brochures

Norm EN 814

Air-conditioner

Energy Label Directive 2002/31/EC

Air-conditioner

GC 9 DCI R410

ST FLO 9 DCI

A

295

2.5

4.2

3.4

A

26

The labelling classifies air conditioning systems in 7 categories (from A to G) in relation to their energy consumption. Those appliances with the best energy efficiency are awarded an A label (Green colour arrow on the label) those with the lowest energy efficiency a G label (Red colour arrow).

This label also includes a certain number of details (Brand, Model, Cooling and heating capacity, Noise level) and allows the user to compare the efficiency of different products.

WEEE (WASTE ELECTRICAL AND

ELECTRONIC EQUIPMENT)

On 13 th August 2005, the new European Directive on Waste Electrical and Electronic Equipment (WEEE) came into force.

The Directive's aim is to regulate the disposal of electronic waste by separating its treatment from that of household waste.

Selective collection systems are being put in place to recover all WEEE with the view to recycling.

This Directive requires air conditioning appliance manufacturers and distributors to:

• Mark certain models marketed after 13 th August 2005.

• Meet financial obligations associated with end-of-life appliance recycling.

As users of our products, and on those products covered by the Directive, you will observe a pictogram (see illustration below) on the Maker's plate representing a "crossed-out refuse bin". This pictogram is intended to inform the user that the appliance in question must be disposed of separately from household waste.

As part of its sustainable development policy, along with the entire profession, Airwell is committed to abiding by this new European initiative. Our environment is precious, let's preserve it.

9

AIRCONET

Remote management of your air conditioning network

Airconet is a complete, powerful and user-friendly system providing remote management of air conditioning installations in an overall and customised manner:

• Centralised control of a group of indoor units (building, floor…).

• Individual control in each pre-defined room and zone.

Irrespective of the type of building, by way of a simple PC connected to the Internet or to the building's local network, Airconet provides total control of a complete air conditioning system.

In fact, from the Airconet communication gateway connected to each of the indoor units and depending on access rights granted, the user can regulate blown air temperatures and fan speeds and even receive e-mail or SMS alerts regarding any system malfunctions, etc.

PRINCIPLE

The heart of the system is the Airconet communication gateway. This is a module installed on site and connected, on the one hand to all the air conditioning units to be managed by way of an MIU (Modbus Interface Unit) and, on the other hand, to a LAN/WEB network. In this manner, the user can connect to the communication gateway via a PC with an internet connection.

Thanks to the Plug & play system there is no requirement for the user to install any special software as this is already loaded in the Airconet communication gateway. Via the PC's internet navigator, it is possible to set and alter parameters such as room temperatures and timer programming as well as to be alerted in the event of any possible malfunctions.

INSTALLATION ARCHITECTURE e-mail

LAN / WEB

SMS

Managed site

Basic configuration: (1) Airconet communication gateway module 1 per site capable of managing up to 247 indoor units, 1 MIU (2) per indoor unit depending on the unit type.

10

BENEFITS

Improved occupant comfort (e.g. timing a unit to start operating before the arrival of the client/occupant).

Lower energy bills by way of energy savings derived from overall installation control, and therefore close control of energy consumption.

Simplified management and improved maintenance thanks to optimal installation control and real time interventions.

Extended equipment service life.

Completely upgradeable system.

Real time alerts by e-mail or SMS of any installation malfunction.

ADVANTAGES

User-friendly, straightforward, efficient and autonomous interface.

Plug and Play installation, no software installation, modem integrated in the communication Gateway.

Integrated system supervision, easy to use.

Choice of languages.

Perfect compatibility with Windows operating systems: XP, 2000, NT, 98,…

Up to 247 units managed by a single communication

Gateway.

Very low investment.

Several user levels

LEVEL USER

3

4

1

2

5

Company employee

Reception manager (hotels…)

Maintenance manager

Technician

Supervisor/Developer

POSSIBILITIES

Local normal control of an individual unit

Centralised normal control of all units

Communication gateway information verification

System definition

Database and parameters

CLIENT

SERVICE

Communication gateway (1)

RANGE

Managed with all indoor units

SIZE

Managed with all sizes

PART NUMBER

AIRCONET006

MIU - Communication cards (2)

RANGE

COMFORT

INDUSTRIAL

MODEL SIZE

SIMPLY 9-12-18-24

FLO 30

XLS 9

SX 12-18-24-30

KLV

KXL

BS

DHC

DK/DN

HA

9-11-15-18-24

30-36-45

11-15-18

46-54 all sizes all sizes

PART NUMBER

AIRCONET050

AIRCONET080

AIRCONET100

AIRCONET030

AIRCONET030

AIRCONET110

AIRCONET070

AIRCONET070

SP000000063+SP000000161

SP000000063+SP000000161

NOTE 1 : Each "Airconet XXX" reference includes the communication board (MIU) as well as the connections required for connecting to the unit.

NOTE 2 : In addition to 40 MIU boards connected to the communication gateway, a REPEATER (free of charge supply) must be installed.

11

COMFORT

RANGE

12

NEW 2007

S (floor-ceiling)

SX TELECOM (floor-ceiling)

CCE 45 (column)

AELY (mobiles)

VAR & CAO (monoblocs)

>

Comfort for everyone

At home, in offices and shops... the Comfort range has been designed specially with you in mind. Your expectations differ... so do our solutions. With both cooling only and heat pump models available, Airwell offers you a broad range of air-conditioning systems in various format : monobloc, wall mounted, consoles, cassettes, duct units...

Wall mounted p.14

Floor-ceiling p.20

Monoblocs p.30

Cassettes p.34

Ducted p.38

Multisplits p.42

13

Ducted Multisplits Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

RELAX SIMPLY FLORIDA

RELAX

Wall mounted splits

4 Cooling Only models from 2 120 to 5 100 W

4 Heat Pump models from 2 150 to 5 550 W

Indoor units RELAX 7/9 Outdoor units GC 7/9

Supplied with RC5 remote control

> Product advantages

Automatic regulation Cold/Hot.

2 ventilation speed.

Timer.

Slow down at night.

Dehumidification.

Compact and lightweight for easy installation and maintenance.

Accessories

Condensate lift pump

All seasons kit

Mounting bracket

RELAX 7

Part number SAE3100

Part number 7ACFH0077

Part number 7ACTL0016

RELAX 9

SAE3100

7ACFH0077

7ACTL0016

RELAX 12

SAE3100

7ACFH0077

7ACTL0016

RELAX 18

SAE3100

7ACFH0077

7ACTL0016

RELAX

RELAX Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits

Indoor units

Dehumidification

Air flow speed low/high

Acoustic pressure to 1m

Weight

Dimensions (WxDxH)

Part number kW 2.12

0.73

2.9/C

RELAX 7

RELAX 7RC kW 2.15

0.69

3.12/D

ST RELAX 7 l/h 320/400 m 3 /h 31/37 dB (A) 0.7

kg 7 mm 680x180x250

7SP022178

Outdoor units

Compressor type

Acoustic pressure to 1m

Weight

Dimensions (WxDxH)

Part number

Part number

GC RELAX 7

GC RELAX 7RC

Rotary dB (A) 52 kg 23 mm 600x250x500

Power supply 1~230V 7SP061533

Power supply 1~230V 7SP061534

Linking specifications between indoor and outdoor units

Power supply 1~230V

Power supply side

Power cable section

Fuse rating am (1~230V)

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes (not supplied)

Max. lenght

Max. height

Suction pipe diameter

Liquid pipe diameter mm mm mm m

2

2

Ind.

3x1

A 10

2 4x1

5x1

10 m 7

Inches 3/8”

Inches 1/4”

Ind.

3x1

10

4x1

5x1

12

7

3/8”

1/4”

RELAX 9

RELAX 9RC

2.53

0.97

2.61/D

RELAX 12

RELAX 12RC

3.50

1.24

2.82/C

10/46°C Dry Bulb

2.63

0.90

2.92/D

3.60

1.28

2.81/D

-9/24°C Dry Bulb

ST RELAX 9

350/450

36/40

1.0

7

680x180x250

7SP022179

ST RELAX 12

450/600

36/42

1.7

8

840x180x250

7SP022180

GC RELAX 9

GC RELAX 9RC

Rotary

54

26

600x250x500

7SP061535

7SP061536

GC RELAX 12

GC RELAX 12RC

Rotary

55

37

760x245x545

7SP061537

7SP061538

RELAX 18

RELAX 18 RC

5.1

1.93

2.64/D

5.55

1.9

2.92/D

ST RELAX 18

450/670

35/44

2.2

12

900x200x295

7SP022303

GC RELAX 18

GC RELAX 18RC

Rotary

49

42

795x610x290

7SP061577

7SP061578

Ind.

3x1.5

16

4x1.5

5x1.5

15

7

1/2”

1/4”

Ind.

3x1.5

16

4x1.5

5x1.5

15

7

1/2”

1/4”

Ducted Multisplits Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

RELAX SIMPLY FLORIDA LOUISIANA

Indoor units SIM 9/12

SIMPLY

Wall mounted splits

4 Cooling Only models from 2 500 to 6 540 W

>

4 Heat Pump models from 2 720 to 7 900 W

Supplied with RC5 remote control

Product advantages

Automatic vertical treated air sweeping.

High filtration.

Compact and lightweight for easy installation and maintenance.

Two fan speeds.

Slow down at night.

SIMPLY Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits

SIM 9

SIM 9 RC kW 2.50 kW 0.96

2.6/D kW 2.72

kW 1.05

2.59/F

Indoor units

Dehumidification

Air flow (LS/HS)

Acoustic pressure at 1m (LS/HS)

Weight

Dimensions (WxDxH)

Part number

ST SIM 9 l/h 1 m 3 /h 310/390 dB(A) 33/38 kg 8 mm 815x170x280

7SP022106

Outdoor units

Compressor type

Air flow

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number

Power supply 1~230 V

Power supply 1~230 V

Linking specifications between indoor and outdoor units

Power supply 1~230V

Power supply side

Power cable section

Fuse rating am

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes

Max. lenght

Max. height

Suction pipe diameter

Liquid pipe diameter

* In the case of connections on an indoor unit.

GC SIM 9

GC SIM 9 RC

Rotary m 3 /h 1370 dB(A) 56 kg 31 mm 760x245x545 mm mm m m

Inches

Inches

2

2

7SP061304

7SP061305

Ind.

3x1

A 10

4x1

5x1

10

7

3/8”

1/4”

Outdoor units GC

SIM 9/12

SIM 12

SIM 12 RC

3.23

1.29

2.5/E

SIM 18

SIM 18 RC

5.00

1.85

2.7/D

10/46°C Dry Bulb

3.50

1.36

2.57/F

5.27

1.95

2.70/E

-9/24°C Dry Bulb

ST SIM 12

1.5

385/450

33/41

9

815x170x280

7SP022107

GC SIM 12

GC SIM 12 RC

Rotary

1460

58

37

760x245x545

7SP061306

7SP061307

ST SIM 18

2.2

580/830

40/46

13

1115x200x330

7SP022181

GC SIM 18

GC SIM 18 RC

Rotary

2160

56

43

795x290x610

7SP061531

7SP061549

Remote control RCW2

Part number 7ACEL1212

SIM 24

SIM 24 RC

6.54

2.33

2.8/D

7.90

2.66

2.70/E

ST SIM 24

2.6

690/990

44/50

14

1115x205x330

7SP022182

GC SIM 24

GC SIM 24 RC

Rotary

2480

61

62

846x302x690

7SP061532

7SP061550

Ind.

3x1.5

16

4x1.5

5x1.5

15

7

1/2”

1/4”

Ind. or Out.

3x1.5

16

4x1.5*

5x1.5*

15

7

1/2”

1/4”

Ind.

3X2.5

20

4x2.5

5x2.5

15

7

5/8”

3/8”

16

Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

RELAX SIMPLY FLORIDA LOUISIANA

FLORIDA

Wall mounted splits

1 Cooling Only model of 8 500 W

1 Heat Pump model of 9 500 W

Ducted Multisplits

Indoor unit FLORIDA 30

Supplied with RC4 remote control

FLORIDA Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits kW kW

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits kW kW

Indoor unit

Air flow (LS/HS)

Acoustic pressure at 1m (LS/HS)

Weight

Dimensions (WxDxH)

Part number m 3 /h dB(A) kg mm

ESF + LCD Models

Outdoor units

Compressor type

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number

Part number

Part number dB(A) kg mm

Power supply 1~230 V

Power supply 3N~400 V

Power supply 1~230 V

Power supply 3N~400 V

Linking specifications between indoor and outdoor units

Power supply 1~230V

Power supply side

Power cable section

Fuse rating am

Electrical connections In./Out.

Electrical connections In./Out.

Power supply 3N~400 V

Power supply side

Power cable section

Fuse rating am

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes

Max. lenght

Max. height

Suction pipe diameter

Liquid pipe diameter mm mm mm mm mm mm

A m m

Inches

Inches

2

2

2

2

A

2

2

Out.

3x4

25

5x2.5

6x2.5

Out.

5x2.5

3x16

5x2.5

6x1.5

30

15

5/8”

3/8”

FLO 30

FLO 30RC

8.5

3.1

2.74/D

10/46°C Dry Bulb

9.5

3.25

2.02/D

-9/24°C Dry Bulb

ST FLO 30

1300

44/48/52

18.5

1280x340x236

7SP022275

GC 30

GC 30RC

Scroll

61

84

900x340x970

7SP061403

7SP061405

7SP061404

7SP061406

Outdoor unit GC 30

> Product advantages

Automatic sweeping of treated air.

LCD screen.

ESF model: ioniser and prefilter.

Accessories

Condensate lift pump

All seasons kit

Mounting bracket

Part nbr

Part nbr

Part nbr

FLO 30

SAE3100

7ACFH0078

7ACTL0018

17

Ducted Multisplits Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

RELAX SIMPLY FLORIDA LOUISIANA

XLS

Low / high wall mounted Splits

2 Cooling Only models from 2 640 to 3 460 W

2 Heat Pump models from 2 860 to 3 800 W

Supplied with RC4 remote control

Indoor units XLS

9/12

Outdoor unit

GCNG 9/12

> Product advantages

Low or high wall mounted installation.

Innovative, ultra-compact design (only 14 cm deep).

High performance filtration.

Electronic regulation and programming.

Treated air distribution from all 4 sides.

Ultra-quiet operation – Only 36 dBA at 1 m.

Wall mounted RCW2 remote control (accessory)

Condensate drainage lift pump (accessory).

BLOWN AIR IN 4 DIRECTIONS

Treated air is distributed in four directions. The user can direct the treated air to optimise comfort levels, depending on the chosen operating mode:

Cooling mode: air blown upwards falls back down evenly to cool the room.

Heating mode: air blown towards the floor rises progressively to spread more effectively throughout the room.

Side blowing: ensures uniform air distribution throughout the room without creating the feeling of draughts.

Gre y

CHOOSE YOUR COLOUR!

Yellow

Cobalt blue

Champagne

Tropical blue

Accessories

Mounting bracket

Condensate lift pump

Colored frame

Nota : Three panels per set.

18

Part number

Part number

Part number 7ACVF0151

Colour

Pantone 427

Grey

XLS 9

7ACTL0016

SAE3100

7ACVF0152

475

Champagne

7ACVF0153

120

Yellow

Remote control RCW2

Part number 7ACEL1212

XLS 12

7ACTL0016

SAE3100

7ACVF0154

535

Cobalt blue

7ACVF0155

552

Tropical blue

XLS Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits

Indoor units

Air flow (LS/NS/HS)

Acoustic pressure at 1m (LS/HS)

Weight

Dimensions (WxDxH)

Part number

Watt

Watt

Watt

Watt m 3 /h dB(A)

Kg mm

Outdoor units

Compressor type

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number dB(A)

Kg mm

Power supply 1~230 V

Power supply 1~230 V

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power supply side

Power cable section

Fuse rating am

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes

Max. lenght

Max. height

Suction pipe diameter

Liquid pipe diameter mm 2

A mm 2 mm 2 m m

Inches

Inches

LOUISIANA XLS

XLS 9

XLS 9 RC

2.64

1.04

2.54/E

2.86

0.95

3.01/D

ST XLS 9

340/370/400

38/40/42

14

570x140x570

7SP022079

GC 9

GC 9 RC

Rotary

53

35

760x245x545

7SP061200

7SP061052

21/46° Dry Bulb

XLS 12

XLS 12 RC

3.46

1.30

2.66/D

3.80

1.27

2.99/D

-9/24°C Dry Bulb

ST XLS 12

330/370/440

38/41/45

14

570x140x570

7SP022080

GC 12

GC 12 RC

Rotary

53

38

760x245x545

7SP061201

7SP061035

Ind.

3x1.5

10

4x1.5

5x1.5

10

7

3/8”

1/4”

Ind.

3x1.5

16

4x1.5

5x1.5

12

7

1/2”

1/4”

19

Wall mounted

Floor/Ceiling splits Monoblocs Cassettes Ducted Multisplits

SX S SX SP SX T

SX

Floor/Ceiling splits

5 Cooling Only models from 2 640 to 8 800 W

5 Heat Pump models from 2 700 to 8 420 W

Indoor units

SX 9/12/15/18

CCE

Supplied with RC4 remote control

> Product advantages

Low wall mounted or ceiling mounted indoor units.

Automatic horizontal and vertical treated air sweeping.

Compact and lightweight for easy installation and maintenance.

Possibility of air conditioning two separate rooms with a single indoor unit.

High efficiency filtration.

Control panel

Outdoor units GCNG 9/12/14/18

Ultra simple

Mounting template for preparing both low wall mounting and ceiling installation.

Ultra quick

Wall bracket used for pre-fitting and attaching pipe links

(pipe outlet possible on the rear, left or right).

Ultra practical

Direct access to electrical and refrigeration connections without dismantling the unit.

Accessories

Single phase electric heating

Single phase electric heating

Three phases electric heating

SX 9

Capacity (W) 1250

Part number 7ACEL1153

Capacity (W) -

Part number -

Capacity (W) -

Part number -

Part number 7ACFH0221

SX 12

1250

7ACEL1153

1000

7ACEL1172

-

-

7ACFH0221 Condensate lift pump

Air distribution unit

Rear panel tube cover (ceiling mounting)

Part number 7ACVF0122

Part number 7ACTL0073

7ACVF0122

7ACTL0073

Mounting bracket Part number 7ACTL0016

NOTE : Important, installation of an all seasons kit only allows for operation in cooling mode.

7ACTL0016

SX 18

2000

7ACEL1154

-

-

-

-

7ACFH0221

7ACVF0122

7ACTL0073

7ACTL0018

Remote control RCW2

Part number 7ACEL1212

SX 24

3000

7ACEL1155

1500

7ACEL1173

3000

7ACEL1156

7ACFH0221

7ACVF0123

7ACTL0074

7ACTL0018

SX 30

3000

7ACEL1155

1500

7ACEL1173

3000

7ACEL1156

7ACFH0221

7ACVF0123

7ACTL0074

7ACTL0018

20

CALIFORNIA SX

CALIFORNIA SX Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits

Indoor units

Dehumidification

Air flow (LS/NS/HS)

Acoustic pressure at 1m (LS/NS/HS)

Weight

Dimensions (WxDxH)

Part number

SX 9

SX 9 RC kW 2.64

kW 1.07

2.47/E kW 2.70

kW 1.07

2.52/F

SX 12 SX 18 SX 24 SX 30

SX 12 RC SX 18 RC SX 24 RC SX 30 RC

3.52

1.36

2.59/E

5.42

1.92

2.82/C

10/46°C Dry Bulb

7.12

2.58

2.76/D

8.8

3.68

2.39/F

3.52

1.36

2.59/F

5.85

1.92

3.05/D

-9/24°C Dry Bulb

7.46

2.58

2.89/D

8.42

3.68

2.29/G

ST SX 9 ST SX 12 ST SX 18 ST SX 24 ST SX 30 l/h 1.0

2.4

2.5

m 3 /h 290/330/350 350/390/420 460/515/560 700/820/930 740/895/1020 dB(A) 35/37/38 38/41/45 40/44/48 44/48/52 45/51/54 kg 21 mm 820x190x630

21

820x190x630

23

820x190x630

29.5

32

1200x190x630 1200x190x630

7SP012001 7SP012002 7SP012004 7SP012005 7SP012007

Outdoor units

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number

Part number

Part number

GC 9

GC 9 RC

GC 12

GC 12 RC

GC 18

GC 18 RC

GC 24

GC 24 RC

GC 30

GC 30 RC

Rotary dB(A) 42 kg 31

Rotary

43

37

Scroll Scroll Scroll

47

56

47

58

49

84 mm 760x245x545 760x245x545 850x370x690 850x370x690 900x380x680

Power supply 1~230 V 7SP061200

Power supply 3N~400 V -

Power supply 1~230 V 7SP061052

Power supply 3N~400 V -

-

7SP061201

7SP061035

7SP061332

7SP061333

7SP061334

7SP061335

7SP061340

7SP061341

7SP061342

7SP061343

7SP061403

7SP061405

7SP061404

7SP061406

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power supply side

Fuse rating am

Power cable section (without heating)

Electrical connections In./Out.

Electrical connections In./Out.

mm 2 mm 3 mm 3

Ind.

A 10

3x1.5

4x1

5x1

Power supply 3N~400 V

Power supply side

Fuse rating am

Power cable section (without heating)

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes

Max. lenght

Max. height difference

Suction pipe diameter

Liquid pipe diameter

* In the case of connections on an indoor unit.

mm mm mm

A -

m m

Inches

Inches

2

3

3

-

-

-

15

7

3/8”

1/4”

-

-

-

-

-

Ind.

16

3x1.5

4x1.5

5x1.5

15

7

1/2”

1/4”

Ind. or Out.*

20

3x2.5

5x2.5*

6x2.5*

Out.

3x6

5x1.5

5x1.5

6x1.5

25

10

5/8”

3/8”

Ind. or Out.*

20

3x2.5

5x2.5*

6x2.5*

Out.

3x8

5x1.5

5x1.5

6x1.5

15

7

5/8”

3/8”

Out.

25

3x4

5x1.5

6x1.5

Out.

3x10

5x1.5

5x1.5

6x1.5

30

10

5/8”

3/8”

21

Wall mounted

Floor/Ceiling splits Monoblocs Cassettes Ducted Multisplits

SX S SX SP SX T

S

NEW

Floor/Ceiling splits

2 Cooling Only models from 10 100 to 13 000 W

2 Heat Pump models from 11 000 to 13 900 W

CCE

Indoor units

S 110/130 GCN 37/43

Supplied with RC4 remote control

> Products advantages

Multi-position architecture for low wall and ceiling mounting.

Indoor units with direct blowing.

Linking pipes until 50 m.

Compatible with Airconet Regulation.

22

S Series

Cooling capacity

Power input

EER / Label Energy

Heating capacity

Power input

COP / Label Energy

Indoor units

Air flow (LS/NS/HS)

Acoustic pressure to 1 m (LS/NS/HS)

Weight

Dimensions (WxDxH)

Part number m 3 /h dB(A) kg mm

Outdoor units

Air flow

Acoustic pressure to 1 m

Compressor type

Weight

Dimensions (WxDxH)

Part number

Part number m 3 /h dB(A) kg mm

Linking specifications between indoor and outdoor units

Power supply

Power supply side

Power cable section

Fuse rating am

Electrical connections

Electrical connections

Linking pipes

Max. lenght

Max. height

Suction pipe diameter

Liquid pipe diameter mm mm mm

A m m

Inches

Inches

2

2

3 kW kW kW kW

S

1~230V

Outdoor

5x2.5

3x25

5x2.5

6x2.5

50

25

3/4”

3/8”

S 110

S 110 RC

10.10

3.48

2.9/F

11.00

3.90

2.82/D

ST S110

815/980/1180

48/52/56

45

1280x255x590

7SP022737

GCN 37

GCN 37 RC

4150

61

Rotary

87

900x340x970

7SP061622

7SP061631

3N~400V

Outdoor

5x2.5

3x20

5x2.5

6x2.5

50

25

3/4”

3/8”

S 130

S 130 RC

13.00

4.56

2.85/C

13.90

4.86

2.86/D

ST 130

1300/1480/1600

53/56/58

56

1585x255x590

7SP011076

GCN 43

GCN 43 RC

4350

64

Scroll

96

900x340x970

7SP061624

7SP061633

23

Wall mounted

Floor/Ceiling splits Monoblocs Cassettes Ducted Multisplits

CCE SX S SX SP SX T

SX SP

Floor/Ceiling splits

indoor temperature until 12°

4 Cooling Only models from 1 850 to 5 550 W

Outdoor units GCNG 9/12/15

Indoor units SX SP 12/15/18

> Applications

Wine cellars.

Areas subject to health & safety regulations

(refuse collection areas, …).

Hospitals.

Conservation, storage, production processes, …

Low temperature environment air conditioning.

> Product advantages

Indoor temperature from 12°C to 18 °C.

Floor or ceiling mounting.

Integrated or remote regulation.

All Seasons System supplied as standard equipment with the indoor unit (to be fitted to the outdoor unit).

Anti-freezing safety protection with anti-freezing thermostat on the indoor unit.

Electric heating (accessory).

Accessories

Single phase electric heating

Rear panel tube cover (ceiling mounting)

Mounting bracket

24

Capacity (W)

Part number

Part number

Part number

SX SP 12

1000

7ACEL1172

7ACTL0073

7ACTL0016

SX SP 15

1000

7ACEL1172

7ACTL0073

7ACTL0016

SX SP 24

1500

7ACEL1173

7ACTL0074

7ACTL0018

SX SP 30

1500

7ACEL1173

7ACTL0074

7ACTL0018

SX SP

SX SP Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Indoor units

Air flow

Acoustic pressure

Weight

Dimensions (WxDxH)

Part number

SX SP 12 kW 1.85

kW 1.31

1.41/G

ST SXSP 12 m 3 /h 350 dB(A) 38 kg 20 mm 820x190x630

7SP012090

Outdoor units

Compressor type

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number

GC 9

Rotary dB(A) 42 kg 31 mm 760x245x545

Power supply 1~230V

Power supply 3N~400V -

7SP061200

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power supply side

Power cable section (without heating)

Fuse rating am

Electrical connections

Power supply 3N~400V

Power supply side

Power cable section (without heating)

Fuse rating am

Electrical connections

Linking pipes

Max. lenght

Max. height difference

Suction pipe diameter

Liquid pipe diameter mm mm mm mm

2

2

A -

2 -

-

-

Ind.

3x1.5

A 10

2 5x1.5

m 15 m 7

Inches 1/2”

Inches 1/4”

-

-

-

-

Ind.

3x1.5

10

5x1.5

15

7

1/2”

1/4”

SX SP 15

2.07

1.70

1.22/G

SX SP 24

4.39

2.64

1.66/G

-10/43°C Dry Bulb

ST SXSP 15

450

44

21

820x190x630

7SP012091

ST SXSP 24

735

44

30

820x190x630

7SP012093

GC 12

Rotary

43

37

760x245x545

-

7SP061201

GC 18

Scroll

47

56

850x370x690

7SP061332

7SP061333

SX SP 30

5.55

3.41

1.63/G

ST SXSP 30

895

47

32

820x190x630

7SP012094

GC 24

Scroll

47

58

850x370x690

7SP061340

7SP061341

Ind. or Out.

3x1.5

16

5x1.5

Out.

5x1.5

3x6

5x1.5

25

10

5/8”

3/8”

Ind. or Out.

3x2.5

16

5x1.5

Out.

5x1.6

3x6

5x1.5

25

10

5/8”

3/8”

25

Wall mounted

Floor/Ceiling splits Monoblocs Cassettes Ducted Multisplits

CCE SX S SX SP SX T

SX TELECOM

Floor/Ceiling splits

3 Cooling Only models from 5 200 to 8 400 W

Indoor unit SX 18T Outdoor units GC 18/24

> Applications

System specially designed for process applications, equipped with several safety systems and full electromagnetic radiation

(EMR) protection.

> Product advantages

HP pressostat.

All Seasons kit -10°C.

Progressive starting.

Short cycling management.

Electromechanical regulation:

- automatic resetting in case of power cuts

- dry contact operating fault protection devices (HP safety, anti-frost safety, excessive blown air temperature safety)

- Remote ON/OFF control.

Accessories

Condensat lift pump

Mounting bracket

Rear panel tube cover

26

SX 18T

7ACFH0221

7ACTL0018

7ACTL0073

SX 24T

7ACFH0221

7ACTL0018

7ACTL0074

SX 30T

7ACFH0221

-

7ACTL0074

SX TELECOM

SX TELECOM Series

Cooling capacity

Power input

EER / Energy Label

Operating limits OUT.T

Indoor units

Air flow

Acoustic pressure at 1 m

Weight

Dimensions (WxDxH)

Part number

Outdoor units

Acoustic pressure at 1 m

Weight

Dimensions (WxDxH)

Part number

Part number kW 5.2

kW 2.1

2.5 / E

SX 18T

ST SX 18 T m 3 /h 450/500/550 dB(A) 40/44/48 kg 21 mm 820x190x630

7SP012097S

SX 24T

7.0

2.6

2.7 / D

-10/+46 °C

ST SX 24 T

630/735/840

43/47/50

29.5

1200x190x630

7SP012098S

8.4

3.4

2.5 / C

SX 30T

ST SX 30 T

740/895/1020

45/51/54

32

1200x190x630

7SP012096S

GCN 18 T GC 24 GC N 30 T dB(A) 47 47 41

Scroll Scroll Scroll kg 56 mm 846x302x690

56

846x302x690

82

900x340x860

1~230 V model 7SP061574S

3N~400 V model 7SP061652S

7SP061575S

-

7SP061576S

7SP061573S

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power supply side

Power cable section (without heating)

Fuse rating am

Electrical connections mm 2

In. or Out.

3x2.5

mm

A 12

2 5x1

Power supply 3N~400 V

Power supply side

Power cable section (without heating)

Fuse rating am

Electrical connections

Linking pipes

Max. lenght

Max. height

Suction pipe diameter

Liquid pipe diameter mm mm m

2

A -

2 -

-

-

25 m 10

Inches 5/8”

Inches 3/8”

-

-

-

-

In. or Out.

3x2.5

16

5x1

25

10

5/8”

3/8”

Outdoor

3x4

25

5x1

Outdoor

5x1.5

10

5x1.5

25

10

5/8”

3/8”

27

Wall mounted

Floor/Ceiling splits Monoblocs Cassettes Ducted Multisplits

CCE SX S SX SP

CCE

Column Split System

1 Heat Pump model of 15 000 W

NEW

SX T

Multifunction control panel

Automatic Cooling/ Heating regulation.

3 fan (ventilation) speeds.

Automatic ventilation.

Night time low running

(SLEEP) function.

Dehumidification mode.

Programming (TIMER) function.

LCD display.

Indoor unit CCE 45 RC

28

Outdoor unit GC 45 RC

> Product advantages

Multifunction control panel with LCD display.

High efficiency filtration.

Clogged filter indicator.

Ioniser.

Automatic treated air sweeping.

Air range: 12 m.

Electronic regulation and programming.

Scroll compressor.

Phase controller.

Refrigeration pipe lengths up to 40 m.

CCE 45 Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits

Indoor unit

Air flow (HS)

Acoustic power (min/max)

Weight

Dimensions (WxDxH)

Part number m 3 /h dB(A) kg mm

Outdoor unit

Compressor type

Acoustic power

Weight

Dimensions (WxDxH)

Part number dB(A) kg mm

Linking specifications between indoor and outdoor units

Power supply 3N~400 V

Power supply side

Power cable section

Fuse rating am

Electrical connections

Linking pipes

Max. lenght

Max. height difference

Suction pipe diameter

Liquid pipe diameter mm 2

A mm 2

Inches

Inches m m kW kW

°C kW kW

°C

CCE

CCE 45 RC

12.9

4.82

2.7 / D

21°/ 46° Dry Bulb

15

4.57

3.2 / C

-9°/ 24° Dry Bulb

CCE 45

2000

52/56

70

600x370x1900

7SP022234

GC CCE 40 RC

Scroll

69

95

900x340x970

7SP061521

Outdoor

5x1.5

10

6x1.5

40

20

3/4”

3/8”

29

Ducted Multisplits Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

AELY MAY VAR

AELY/AELIA N

Portable units

2 Cooling Only models from 2 990 to 3 500 W

1 Heat Pump model of 4 590 W

NEW

CAO

AELY 9

> Product advantages

Monobloc portable units (AELY 9/12) or split portable units (AELIA 14).

No specific installation is required.

High deshumidification capacity.

3 fan speed.

AELY 12

Recycling and filtering of the air.

24h timer programmer.

“I feel” function.

Infrared remote control.

AELIA N 14

IR CONTROL

AELY / AELIA N Series

Cooling capacity

Power Input

EER / Label Energy

Dehumidification

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Indoor units

Air flow (LS/NS/HS)

Acoustic pressure at 1m (LS/NS/HS)

Compressor type

Weight

Dimensions (WxDxH)

Outdoor units

Compressor type

Weight

Dimensions (WxDxH)

1~230 V model kW 2.99

kW 1.13

2.64 / A l/h 1.4

°C

AELY 9 kW kW -

-

Monobloc m 3 /h 280/310/350 dB(A) 52

Rotary kg 35 mm 370x455x876

kg mm -

Part number 7MB021046

Linking specifications between indoor and outdoor units

Linking pipes

Lenght

Max. height difference m m -

30

-

-

AELY 12

3.50

1.45

2.41 / B

2.2

21°/46° Dry Bulb

-

-

-

Monobloc

470/520/570

53

Rotary

45

840x450x550

-

-

-

7MB021044

AELIA N 14 IR

4.17

1.54

2.7 / A

1.80

4.59

1.39

3.3/A

Split System

356/401/433

48/50/51

-

38

470x360x800

Rotary

17

440x320x540

7MB021040

3

1.6

Ducted Multisplits Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

AELY MAY

MAY

Window units

5 Cooling Only models from 2 140 to 6 400 W

1 Heat Pump model of 3 200 W

VAR CAO

MAY 110

MAY 70/90

> Product advantages

Sober and unobtrusive design.

Easy to install and operate.

Built into a wall or window.

Drawer chassis.

MAY 180/220

Reusable filter.

Thermostatic temperature regulation.

Angle adjustable blown air flap for even air distribution.

New outdoor air intake device.

MAY Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

MAY 70 kW 2.14

kW 0.82

2.6/C

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits kW kW -

-

Indoor units

Air flow - normal speed

Acoustic pressure at 1m (LS/HS)

Compressor type m 3 /h dB(A)

310

41/44

Rotary

Weight kg 37

Dimensions (WxDxH) mm 450x590x350

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power cable section

Fuse rating am

1~230 V model mm 2 3x1.5

A 6

Part number 7WT012015

-

-

-

MAY 90

2.54

1.06

2.4/E

340

42/46

Rotary

37

450x590x350

3x1.5

6

7WT012016

-

-

-

MAY 110 MAY 180 MAY 220 MAY 110 RC

3.28

1.46

2.2/E

5

2.25

2.2/E

21/46° Dry Bulb

6.4

2.65

2.4/D

3.2

1.3

2.5/E

-

-

-

-9/24° Dry Bulb

-

-

-

3.20

1.10

2.9/D

500

47/54

Rotary

47

560x610x375

800

54/59

Rotary

63

670x710x455

920

57/61

Rotary

70

670x710x455

500

56/57

Rotary

47

560x610x375

3x1.5

8

7WT012017

3x1.5

10

7WT012028

3x1.5

16

7WT012030

3x1.5

8

7WT012012

31

Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

AELY MAY

VAR

NEW

Monobloc air Console

1 Cooling Only model of 2 520 W

Ducted Multisplits

VAR CAO

VAR 9

Control panel

32

> Product advantages

Monobloc console concept without an outdoor unit.

Ideal solution for premises where it is impossible to install an outdoor unit.

Easy installation and maintenance.

Ready to operate system.

Floor mounted or low wall mounted.

Compact design.

Reinforced acoustic insulation.

R410A high efficiency fluid.

Factory-fitted 1,500 W electric heating.

LED direct control panel.

AIRCONET compatible system.

Electrostatic filter.

Condensate drainage pipe supplied.

Rear outlet grille kit supplied.

VAR Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Air flow (LS/NS/HS)

Acoustic pressure to 1m (LS/HS)

Dehumidification

Weight

Dimensions (WxDxH)

Part number m 3 /h dB(A) l/h kg mm

1~230 V model kW kW

°C

VAR 9

2.52

0.97

2.6/C

21°/ 43° Dry Bulb

200/250/300

43/45/50

-

43

1080/230/385

7WT012047

Ducted Multisplits Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

AELY MAY

CAO

Water Console

NEW

3 Cooling Only models from 2 300 to 4 700 W

VAR CAO

Indoor units

CAO 230 B/370 B

CAO 580 B

> Product advantages

Easy installation and maintenance.

Ideal solution for premises where it is impossible to install an outdoor unit.

Water condenser for use with the public water network.

Modulating regulation valve for reducing water consumption.

Possibility of new outdoor air intake.

Electric heating (accessory).

Remote control repeater (accessory).

Reusable air filters.

CAO Series

Cooling capacity

Power Input

EER / Label Energy

Operating limits indoor temperature

Condenser inlet water temperature

Indoor units

Air flow nominal (NS/LS)

New air flow

Acoustic pressure at 4m (NS/LS)

Water flow at +15 °C

Compressor type

Weight

Dimensions (WxDxH)

Power supply 1~230 V

Power cable section (without heating)

Fuse rating am

Part number

Accessories

Single phase electric heating

Remote control kW 2.3

kW 0.66

3.4 / E

°C

°C

CAO 230 B m 3 /h 550/450 m 3 /h 60 dB(A) 40/37 l/h 130

Rotary kg 48 mm 1030x226x620 mm 2 3x1.5

A 6

1~230 V model 7CW011016

CAO 230 B

Capacity (W) 2000

Part number 7ACEL0006

Part number 7ACEL0039

CAO 370 B

3

0.85

3.5 / D

15°/ 32° Dry Bulb

10°/ 30°

550/450

60

41/38

170

Rotary

49

1030x226x620

3x1.5

6

7CW011017

CAO 370 B

2000

7ACEL0006

7ACEL0039

4.7

1.3

3.6 / D

CAO 580 B

880/725

80

43/41

270

Rotary

69

1390x226x620

3x1.5

8

7CW011018

CAO 580 B

3000

7ACEL0007

7ACEL0039

33

Wall mounted Floor/Ceiling splits

Monoblocs Cassettes Ducted Multisplits

KLV/KXL MD

KLV/KXL

Cassettes

7 Cooling Only models from 2 650 to 12 500 W

7 Heat Pump models from 2 980 to 14 200 W

Outdoor units GCNG 9/12/14

Indoor units

KXL 30/36/45

Indoor units

KLV 9/11/18/24

Supplied with RC4 remote control GC 36/45

> Product advantages

Four motorised treated air blowing flaps.

Flush fitting into a suspended ceiling.

600x600 and 600x1200 (models 30 and 45).

Flush fitting: 287 mm (KLV) / 230 mm (KXL).

New air intake.

Integrated condensate drainage lift pump.

SIMPLIFIED INSTALLATION AND MAINTENANCE

Condensate drainage lift pump.

Low noise level turbine.

New air intake.

Slide mounted electrical cabinet.

Condensate drainage lift pump supplied as standard equipment.

Lift height up to 600 mm. 1 single attachment point for easy maintenance.

Direct access to all electrical connections and electronic components mounted on a sliding drawer.

LOW BUILT-IN HEIGHT

247 mm

KLV KXL

300 mm

Accessories

Adapter frame solid ceilings

Mounting bracket

All seasons kit

34

Remote control RCW2

Part number 7ACEL1212

K9 LV K11 LV K18 LV K24 LV KXL30 KXL36 KXL45

Part number 7ACVF0091 7ACVF0091 7ACVF0091 7ACVF0091 -

Part number 7ACTL0016 7ACTL0016 7ACTL0018 7ACTL0018 7ACTL0018 7ACTL0013 7ACTL0013

Part number 7ACFH0077 7ACFH0077 7ACFH0077 7ACFH0077 7ACFH0078 -

COLORADO

KLV/KXL

COLORADO KLV/KXL

Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits

Indoor units

Air flow (LS/NS/HS)

Acoustic pressure at 1m (LS/NS/HS)

Condensate drainage pipe (diameter)

Weight

Flush mounted indoor unit (WxDxH)

Frame (WxDxH)

Part number

Part number

Outdoor units

K9LV K11LV K18LV K24LV KXL 30 KXL 36 KXL45

K9LV RC K11LV RC K18LV RC K24LV RC KXL 30 RC KXL 36 RC KXL 45 RC kW 2.65

kW 1.1

2.41/E

3.22

1.05

3.1/B

5.7

1.93

2.95/C

6.8

9.1

2.63

3.34

2.59/E

10/46° Dry Bulb

2.72/D

10.1

3.6

2.81/C

12.5

5

2.5/E kW 2.98

kW 0.97

3.07/D

3.3

0.97

3.4/C

5.8

2.04

2.84/D

7.2

2.67

2.7/E

-9/24° Dry Bulb

9.2

3.27

2.81/D

10.8

3.84

2.81/D

14.2

5.26

2.7/E

K9 LV K11 LV K18 LV K24 LV KXL 30 KXL 36 KXL 45 m 3 /h 430/470/600 dB(A) 33/35/42 mm 16 kg 26

375/500/550

35/37/42

16

26

530/640/760

33/37/40

16

26

590/660/760

37/41/45

16

30

985/1120/1200 1025/1125/1220 1200/1330/1525

47/50/52

32

42

42/44/46

32

48

45/47/50

32

48 mm 571x571x287 571x571x287 571x571x287 571x571x287 840x840x230 840x840x300 840x840x300 mm 625x625x40 625x625x40 625x625x40 625x625x40 950x950x46 950x950x46 950x950x46

Frame included included included included 7ACVF0321 7ACVF0321 7ACVF0321

7SP042037 7SP042038 7SP042040 7SP042041 7SP042079 7SP042081 7SP042083

GC 9

GC 9 RC

GC 12

GC 12RC

GC 18

GC 18 RC

GC 24

GC 24 RC

GC 30

GC 30 RC

GC 36

GC 36 RC

GC 45

GC 45 RC

Rotary dB(A) 41

Rotary

42

Scroll Scroll

47 47

Scroll Scroll Scroll

62 65 65 kg 31 37 56 58 82 93 95 mm 760x245x545 760x245x545 850x370x690 850x370x690 950x340x860 950x350x970 900x350x970

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number

Part number

Part number

Power supply 1~230 V 7SP061200 7SP061201 7SP061332 7SP061340 7SP061403 -

Power supply 3N~400 V 7SP061333 7SP061341 7SP061405 7SP061547

-

7SP061545

Power supply 1~230 V 7SP061052 7SP061035 7SP061334 7SP061342 7SP061404 -

Power supply 3N~400 V 7SP061335 7SP061343 7SP061406 7SP061548

-

7SP061546

Linking specifications between indoor and outdoor units

Power supply 1~230V

Power supply side

Fuse rating am

Power cable section (without heating)

Electrical connections In./Out.

Electrical connections In./Out.

Power supply 3N~400 V

Power supply side

Fuse rating am

Power cable section (without heating)

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes

Max. lenght

Max. height difference

Suction pipe diameter

Liquid pipe diameter

* In the case of connections on an indoor unit.

Ind.

mm

A 10

2 3x1.5

mm 2 mm 2

4x1.5

5x1.5

mm mm mm

-

A -

2

2

2

-

-

m 15 m 7

Inches 3/8”

Inches 1/4”

Indoor units with fitted electric heating

Power supply

Capacity - Heat Pump model

Part number

-

-

-

-

-

Ind.

16

3x1.5

4x1.5

5x1.5

15

7

1/2”

1/4”

Ind. or Out.

Ind. or Out.

Out.

20

3x2.5

20

3x2.5

25

3x4

5x2.5*

6x2.5*

5x2.5*

6x1.5*

5x2.5

6x2.5

Out.

3x6

5x1.5

5x1.5

6x1.5

25

10

5/8”

3/8”

Out.

3x10

5x1.5

5x1.5

6x1.5

25

10

5/8”

3/8”

Out.

3x16

5x2.5

5x1.5

6x1.5

30

10

5/8”

3/8”

-

-

-

-

-

Out.

3x16

5x2.5

5x2.5

6x2.5

50

25

3/4”

3/8”

-

-

-

-

-

Out.

3x16

5x2.5

5x2.5

6x2.5

50

25

3/4”

3/8”

K9 LV CH K11 LV CH K15 LV CH K18 LV CH K24 LV CH KXL30 CH KXL36 CH KXL45 CH

1~230 V

W 900

1~230 V

900

1~230 V

1 500

1~230 V

1 800

1~230 V

1 800

1~230 V

2 700

-

3 000

-

3 000

7SP042120 7SP042121 7SP042122 7SP042123 7SP042124 7SP042080 7SP042082 7SP042084

35

Wall mounted Floor/Ceiling splits

Monoblocs Cassettes Ducted Multisplits

KLV/KXL MD

MD

Ducted Cassettes

3 Cooling Only models from 9 230 to 13 250 W

5 Heat Pump models from 9 380 to 13 370 W

Indoor units MD 35/38/50

Outdoor units GCN 36/43

Supplied with RC4 remote control

> Product advantages

Installation possible in a corridor (width: 850 mm), suspended ceiling installation.

Built-in depth: only 300 mm!

Air intake via room grille, air distribution via outlets on opposite sides.

Available air pressure for connection to a duct network.

Possibility of air conditioning up to 6 rooms.

Condensate drainage lift pump

(up to 600 mm lift height).

New air intake.

Complete accessibility via the unit underside.

Accessories

Air dosing flap

New air intake

Vave-damper 3x8”

Vave-damper 4x8”

Vave-additional damper 10”

36

MD 35

Part number 7ACVF0290

Part number 7ACVF0291

Part number -

Part number -

Part number -

MD 38

7ACVF0290

-

-

7ACVF0291

-

MD 38 DS

7ACVF0290

7ACVF0291

7ACFH0446

7ACFH0380

7ACFH0447

Remote control RCW2

Part number 7ACEL1212

MD 50

7ACVF0290

-

-

7ACVF0291

-

MD

MD Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits

MD 35

MD 35 RC

1~230 V kW 9.23

kW 3.58

2.58/E kW 9.38

kW 3.15

2.98/C

MD 38

MD 38 RC

3N~400 V

10.99

3.85

2.86/C

11.1

3.94

2.82/C

-

MD 38 DS RC

3N~400 V

10.99

3.85

2.86/C

21/46°C Dry Bulb

11.1

3.94

2.82/C

-9/24°C Dry Bulb

MD 50

MD 50 RC

3N~400 V

13.25

5.2

2.55/E

13.37

5.18

2.58/E

-

MD 50 DS RC

3N~400 V

13.25

5.2

2.55/E

13.37

5.18

2.58/E

Indoor units

Air flow (LS/NS/HS)

Available static pressure (min./max.)

Acoustic pressure at 1m (LS/NS/HS)

Weight

Flush mounted indoor unit (WxDxH)

Frame (WxDxH)

Part number

ST MD 35 ST MD 38 ST MD 38DS ST MD 50 ST MD 50 DS m 3 /h 1200/1330/1700 1200/1330/1700 1200/1330/1700 1230/1350/2000 1230/1350/2000 daPa 2/8 dB(A) 45/47/52

2/8

47/50/52

2/8

47/50/52

2/8

47/50/53

2/8

47/50/53 kg 43 mm 1025x760x300 mm 1050x800x100

44

1025x760x300

1050x800x100

44

1025x760x300

1050x800x100

44

1025x760x300

1050x800x100

44

1025x760x300

1050x800x100

7SP022137 7SP022138 7SP022200 7SP022139 7SP022334

Outdoor units

Compressor type

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number

Part number

Part number

GCN 30

GCN 30 RC

Scroll dB(A) 62 kg 82 mm 900x340x860

Power supply 1~230 V 7SP061403

Power supply 3N~400 V 7SP061405

Power supply 1~230 V 7SP061404

Power supply 3N~400 V 7SP061406

Linking specifications between indoor and outdoor units

Power supply 1~230V

Power supply side

Power cable section

Fuse rating am

Electrical connections In./Out.

Power supply 3N~400V

Power supply side

Power cable section

Fuse rating am

Electrical connections In./Out.

Linking pipes

Max. lenght

Max. height difference

Suction pipe diameter

Liquid pipe diameter mm mm mm mm

A 25

2

A m m

Inches

Inches

2

2

2 -

-

-

Out.

3x4

6x2.5 + 2x0.5

30

10

3/8”

5/8”

GCN 36

GCN 36 RC

Scroll

57

93

900x350x970

-

7SP061547

-

7SP061548

-

-

-

-

Out.

5x4

3x10

6x1.5 + 2x0.5

30

25

3/4”

3/8”

-

GCN 36 DS RC

Scroll

57

93

900x350x970

-

-

-

7SP061628

GCN 43

GCN 43 RC

Scroll

57

95

900x350x970

-

7SP061545

-

7SP061546

-

-

-

-

Out.

5x1.5

3x10

6x1.5 + 2x0.5

50

25

3/4”

3/8”

-

-

-

-

Out.

5x1.5

3x10

6x1.5 + 2x0.5

50

25

3/4”

3/8”

-

GCN 43 DS RC

Scroll

57

95

900x350x970

-

-

-

7SP061629

-

-

-

-

Out.

5x2.5

3x10

6x1.5 + 2x0.5

50

25

3/4”

3/8”

37

Wall mounted Floor/Ceiling splits

Monoblocs Cassettes Ducted Multisplits

BS DHC

BS

Ducted

6 Cooling Only models from 3 450 to 12 600 W

6 Heat Pump models from 3 400 to 14 000 W

Indoor units BS 11/18

BS 24/30

Delivered with RC4 remote control

Outdoor units GCNG 12/14 GCN 30/36/40 Receiver

> Product advantages

Suspended ceiling installation.

Horizontal or vertical mounting (models 11/18/24/30).

Horizontal mounting only (models 36 and 43).

Low built in height (300 mm).

Pressure available for connection to a duct network.

Sets of accessories for air intake and distribution via ducts or grilles.

Accessories

N°1 cassette air intake plenum kit

N°2 duct connection plenum kit

Kit Electric heating

All seasons kit

Mounting bracket

38

Remote control RCW2

Part number 7ACEL1212

BS11 BS18 BS24 BS30 BS36 BS43

Part number 7ACVF0075 7ACVF0075 7ACVF0076 7ACVF0076 -

Part number 7ACVF0073 7ACVF0073 7ACVF0074 7ACVF0074 -

Part number 7ACEL1305 7ACEL1306 7ACEL1259 7ACEL1259 7ACEL1267 7ACEL1267

Part number 7ACFH0077 7ACFH0077 7ACFH0077 7ACFH0078

Part number 7ACTL0016 7ACTL0018 7ACTL0018 7ACTL0018

-

-

-

-

BS

BS Series

Cooling capacity

Power Input

EER / Label Energy

Heating capacity

Power Input

COP / Label Energy

Indoor units

Air flow (LS/NS/HS)

Available static pressure

Acoustic pressure at 1 m (MV)

Dimensions (WxDxH)

Weight

Part number

BS11 BS18 BS24 BS30 BS36 BS43

BS11 RC BS18 RC BS24 RC BS30 RC BS36 RC BS43 RC kW 3.20

kW 1.05

3.05/A

4.7

2.02

2.33/C

6.7

2.7

2.48/E

8.56

3.34

2.56/E

9.08

3.24

2.8/D

12.9

4.83

2.67/D kW 3.20

kW 0.96

3.33/A

5.23

1.77

2.95/B

7.3

2.55

2.86/D

9.42

3.04

3.1/D

9.38

2.93

3.2/D

13.77

4.75

2.9/C

ST BS 11 ST BS 18 ST BS 24 ST BS 30 ST BS 36 ST BS 43 m 3 /h 360/450/580

Pa 30 dB(A) 35

660/710/800

30

49

910/1035/1120

32

41

1040/1150/1350

37

53

1175/1380/1535

37

54.5

1430/1600/1765

50

55 mm 860x680x245 860x245x680 1190x270x675 1190x270x680 1115x365x530 1100x300x485 kg 30 31 66 46 37 41

7SP022128 7SP022130 7SP022131 7SP022134 7SP022135 7SP022136

Outdoor units

Compressor type

Acoustic pressure at 1 m

Weight

Dimensions ( WxDxH)

Power supply 1~230 V

Power supply 3N~400 V

Power supply 1~230 V

Power supply 3N~400 V

GCNG 12 GC 18 GC 24 GCN 30 GCN 36 GCN 40

GCNG 12 RC GC 18 RC GC 24 RC GCN 30 RC GCN 36 RC GCN 40 RC

Rotary dB(A) 54

Rotary

53

Scroll

67

Scroll

69

Scroll

69

Scroll

69 kg 35 42 58 82 82 95 mm 830x245x545 795x290x610 850x370x690 900x340x860 900x340x970 900x350x970

Part number 7SP061201 7SP061332 7SP061340 7SP061403 -

Part number 7SP061341 7SP061405 7SP061547

-

7SP061545

Part number 7SP061035 7SP061334 7SP061342 7SP061404 -

Part number 7SP061343 7SP061406 7SP061548

-

7SP061546

Linking specifications between indoor and outdoor units

Power supply 1~230 V - 50 Hz

Power supply side

Power cable section (without heating)

Fuse rating am

Power supply 3N~400 V - 50 Hz

Power supply side

Power cable section (without heating)

Fuse rating am

Linking pipes

Max. lenght

Max. height

Electrical connections In./Out.

Electrical connections In./Out.

mm mm

2

A 10

2 -

-

Indoor

3x1.5

A m 15/7

Inches 1/2-1/4 mm mm

2

2

5x1.5

6x1.5

In. or Out.

In. or Out.

Outdoor

3x1.5

3x1.5

3x2.5

16 20 20

Outdoor

5x1.5

3x6

Outdoor

5x1.5

3x10

Outdoor

5x1.5

3x16

15/7

1/2-1/4

5x1.5

6x1.5

30/10

5/8-3/8

5x1.5

6x1.5

30/10

5/8-3/8

5x1.5

6x1.5

-

-

-

Outdoor

5x1.5

3x16

30/10

5/8-3/8

5x1.5

6x1.5

-

-

-

Outdoor

5x1.5

3x16

50/25

3/4-3/8

5x1.5

6x1.5

39

Wall mounted Floor/Ceiling splits

Monoblocs Cassettes Ducted Multisplits

DHC BS

DHC

Ducted

1 Cooling Only model of 13 480 W

2 Heat Pump models from 7 900 to 16 200 W

Indoor units DHC

Supplied with RC3 remote control

Outdoor units GC 46/54

> Product advantages

Suspended ceiling installation.

Horizontal mounting.

Pressure available for a connection to a ducted network.

40

DHC Series

Cooling capacity

Power Input

EER / Label Energy

Heating Capacity

Power Input

COP / Label Energy

Indoor units

Air flow (normal speed)

Available static pressure

Acoustic pressure at 1m (normal speed)

Dimensions (WxDxH) without accessories

Weight

Part number m 3 /h daPa dB(A) mm kg

Outdoor units

Compressor type

Acoustic pressure at 1m

Weight

Dimensions (WxDxH)

Part number

Part number dB(A) kg mm

Power supply 3N~400 V

Power supply 3N~400 V

Linking specifications between indoor and outdoor units

Power supply 3N~400V

Power supply side

Fuse rating am

Power cable section (without heating)

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes (not supplied)

Max. lenght

Max. height difference

Suction pipe diameter

Liquid pipe diameter

A mm 2 mm 2 mm 2 m m

Inches

Inches kW kW kW kW

DHC

DHC 46

DHC 46 RC

13.48

5.18

2.6/E

13.8

4.44

3.11/D

DHC 46

2120

50

53

1040x595x400

42

7SP022238

GCN 43

GCN 43 RC

Scroll

62

95

900x340x970

7SP061545

7SP061546

Out.

3x16

5x2.5

5x1.5

6x1.5

25

15

3/4”

3/8”

Out.

3x20

5x2.5

5x1.5

6x1.5

50

25

7/8”

1/2”

-

DHC 54 RC

15.8

5.84

2.71/D

16.2

5.23

3.1/D

DHC 54

2310

80

56

1140x680x400

46

7SP022239

-

GCN 50 RC

Scroll

62

110

900x340x1290

-

7SP061480

41

Ducted Multisplits Wall mounted Floor/Ceiling splits

Monoblocs Cassettes

DUO/TRIO

DUO/TRIO

Multisplits

3 Cooling Only models from 4 200 to 7 000 W

6 Heat Pump models from 4 400 to 11 400 W

> Product benefits

Independent operation of each indoor unit.

Rotary compressor.

Possibility of air conditioning two separate rooms with a single unit.

2 or 3 independant cooling circuits.

Rotary compressors.

TRIO 12/12/12

DUO 9/9-9/12-12/12

Compatibility guide

Wall mounted SIMPLY

Cooling capacity

Heating capacity

Air flow (PV/GV)

Acoustic pressure to 1 m (LS/HS)

Weight

Dimensions (WxDxH)

Part number

Wall mounted LOUISIANA XLS

Cooling capacity

Heating capacity

Air flow (LS/HS)

Acoustic pressure to 1 m (LS/HS)

Weight

Dimensions (WxDxH)

Part number

Cassettes COLORADO KLV

Cooling capacity

Heating capacity

Air flow (LS/MS/HS)

Acoustic pressure to 1 m (LS/MS/HS)

Weight

Dimensions (WxDxH)

Part number kW kW m 3 /h dB(A) kg mm

SIM 9 kW 2.5

kW 2.72

m 3 /h 310/390 dB(A) 33/38 kg 8 mm 815x170x280

7SP022106

XLS 9 kW 2.64

kW 2.86

m 3 /h 340/400 dB(A) 38/42 kg 14 mm 570x140x570

7SP022079

KLV 9 kW 2.65

kW 2.98

m 3 /h 430/470/600 dB(A) 33/35/42 kg 26 mm 625x625x40

7SP042037

Floor/Ceiling splits CALIFORNIA SX

Cooling capacity

Heating capacity

Air flow (LS/MS/HS)

Acoustic pressure to 1 m (LS/HS)

Weight

Dimensions (WxDxH)

Part number

SX 9 kW 2.64

kW 2.7

m 3 /h 290/330/350 dB(A) 35/37/38 kg 21 mm 820x190x630

7SP012001

Ducted BS

Cooling capacity

Heating capacity

Air flow (LS/MS/HS)

Acoustic pressure to 1 m (HS)

Weight

Dimensions (WxDxH)

Part number

SIM 12

3.23

3.5

385/450

33/41

9

815x170x280

7SP022107

XLS 12

3.46

3.80

330/440

38/45

14

570x140x570

7SP022080

KLV 11

3.22

3.30

375/500/550

35/37/42

26

625x625x40

7SP042038

SX 12

3.52

3.52

350/390/420

38/41/45

21

820x190x630

7SP012002

BS 11

3.45

3.4

360/450/580

35

30

860x680x245

7SP022128

SIM 18

5.0

5.27

580/830

40/46

13

1115x200x330

7SP022181

KLV 18

5.7

5.8

530/640/760

33/37/40

26

625x625x40

7SP042040

SX 18

5.42

5.85

460/515/560

40/44/48

23

820x190x630

7SP012004

BS 18

5.05

5.43

660/710/800

49

31

860x680x245

7SP022130

42

DUO/TRIO

DUO 7-7 RC

DUO/TRIO Series

Cooling capacity

Power Input

EER / Label Energy

Outdoor temperature operating limits

DUO 9-9 RC DUO 9-9 DUO 9-12 DUO 12-12 -

DUO 7-7 RC DUO 9-9 RC DUO 9-12 RC DUO 12-12 RC DUO 18-18 RC TRIO 12-12-12 RC kW 4,2 (2x2,1) kW 1,70

2,47/E

5,2 (2x2,6)

2,02

2,57/E

6,6 (2x3,3) 7 (2x3,5)

2,83

2,08/G

2,72

2,42/E

21/46°C Dry Bulb

10,9 (2x5,4)

4,37

2,5/E

11,04 (3x3,68)

3,7

2,98/C

Heating Capacity

Power Input

COP / Label Energy

Outdoor temperature operating limits kW 4,4 (2x2,2) kW 1,44

3,06/D

5,4 (2x2,8)

1,96

2,76/E

5,9 (2,6 + 3,3) 7 (2x3,5)

2,33

2,53/F

2,78

2,52/F

-10/46°C Dry Bulb

10,7 (2x5,3)

4,57

2,35/D

11,4 (3x3,8)

3,65

3,12/D

Outdoor units

Compressor type

Ways/compressor

Noise level

Weight

Dimensions ( WxDxH)

Power supply 1~230 V

Power supply 1~230 V

Rotary

2 dB(A) 49 kg 52

Rotary

2

53

60

Rotary

2

53

62

Rotary

2

57

64

Scroll

2

60

110

Rotary

3

60

120 mm 850x370x690 850x370x690 850x370x690 850x370x690 850x325x690 950x340x1270

Part number -

Part number 7SP091099

7SP091105

7SP091100

7SP091101

7SP091102

7SP091103

7SP091104

-

7SP091097

-

7SP091098

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power supply side

Fuse rating am

Electrical connections In./Out.

Electrical connections In./Out.

Linking pipes

Max. lenght

Max. height

Suction pipe diameter

Liquid pipe diameter mm mm mm

2

2

2

-

Outdoor

10

2x (6x1,5) m 2x15 m 2x6

Inches 2x3/8”

Inches 2x1/4”

Outdoor

16

2x (5x1,5)

2x (6x1,5)

2x15

2x6

2x3/8”

2x1/4”

Outdoor

20

2x (5x1,5)

2x (6x1,5)

2x15

2x6

1/2” + 3/8”

2x1/4”

Outdoor

20

2x (5x1,5)

2x (6x1,5)

2x15

2x6

2x1/2”

2x1/4”

Outdoor

32

-

2x (6x2,5)

2x50

2x30

2x5/8”

2x3/8”

Outdoor

32

-

2x (6x2,5)

3x45

3x10

3x1/4”

3x1/2”

43

INDUSTRIAL

RANGE

>

An air of power

Based on its incomparable expertise on this core market, with its 2007 Industrial range, Airwell offers a vast choice of system capacities up to 84,000 Watt. Air or water condenser vertical cabinet units, Ducted packaged units, Rooftop units: a comprehensive range of systems to match all your requirements.

In addition, the DKDN and HA systems are equipped with an intelligent CAC controller microprocessor control facility.

This high-tech PCB not only provides easy access to all system statuses, alarms and sensor data, but also generates significant energy savings, sets the de-icing time duration, etc.

44

Vertical cabinet units p.46

Packaged

Split-System p.50

Rooftop p.52

45

Vertical cabinet units Packaged Split-System Rooftop

XAR XAO

XAR

Vertical air cabinets

6 Cooling Only models from 9 700 to 55 000 W

X 2450 AR*

Indoor unit X 1100 AR* Outdoor units UC 33-53

> Product advantages

Easy installation and maintenance.

Split system with outdoor condenser fan units.

Treated air distribution to premises by plenum or duct network.

Adjustable available static pressure.

Thermostat temperature regulation.

Electrical, refrigeration and thermal protection devices.

Electric heating (accessory).

Hot water coil battery heating (accessory).

”All Seasons” system

(Cooling mode operation down to outdoor temperatures of -10° C).

Remote fault reporting (accessory).

Plenum, duct flanges (accessory).

Accessories X 1100 AR X 1900 AR X 2450 AR X 3250 AR X 4650 AR X6450 AR

Set of female valves

Pipe links

Electric heating

Part nbr 7ACFH0054

Part nbr 7ACFH0210 (1)

Capacity (W) 9000

Part nbr 7ACEL0042

Hot water heating (water at 90/80 °C) Capacity (W) 15500

Confirm left or right side outlet Part nbr 7ACFH0062

7ACFH0055

7ACFH0211

12000

7ACEL0043

29700

7ACFH0063

7ACFH0056

7ACFH0212

18000

7ACEL0057

38500

7ACFH0064

7ACFH0061

7ACFH0213

22500

7ACEL0058

50000

7ACFH0118

7ACFH0057

7ACFH0214

37500

7ACEL0116

77000

7ACFH0180

7ACFH0060

7ACFH0215

45000

7ACEL0119

94000

7ACFH0170

Combined ON/OFF switch and room thermostat (2) Part nbr 7ACEL0041

”High Ventilation”

”All seasons” system

Remote fault reporting kit

Air distribution duct frame

Part nbr

Part nbr

Part nbr

Part nbr

7ACVF0023

7ACFH0069

-

7ACVF0101

7ACEL0041

7ACVF0024

7ACFH0070

-

7ACVF0102

Total rear air intake duct frame

Front air distribution plenum

Part nbr 7ACVF0041

Part nbr 7ACVF0105

7ACVF0104

7ACVF0106

New air intake Part nbr 7ACVF0047 7ACVF0047

(1) Pipe lenghts up to 15m: ref 7ACFH0296 . (2) Switch assembly to be fitted in the room.

* Switch assembly to be fitted in the room.

7ACEL0032

-

7ACEL0104

7ACEL0072

7ACVF0050

7ACVF0043

7ACVF0108

-

7ACEL0032

-

7ACFH0072

7ACEL0072

7ACVF0051

7ACVF0044

7ACVF0109

-

7ACEL0032

-

7ACFH0071

7ACEL0071

7ACVF0052

7ACVF0045

7ACVF0110

-

7ACEL0032

-

7ACFH0146

7ACEL0071

7ACVF0052

7ACVF0046

7ACVF0111

-

46

XAR

XAR Series

Cooling capacity

Power Input

EER

X 1100 AR X 1900 AR X 2450 AR X 3250 AR X 4650 AR X6450 AR kW 9.7

kW 4.2

kW 2.31

15.9

6.7

2.37

20

8.2

2.44

29.03

11.7

2.48

39.8

16.9

2.36

55

24

2.29

Indoor units

Nominal air flow

Air flow range (min./max.)

Available static pressure (max.)

Cooling circuit

Compressor type

Air distribution plenum: height

Noise level

Weight

Dimensions (WxDxH)

Part number m 3 /h 2000 m 3 /h 1500/2500 daPa 0/20

1

Piston mm 220 dB(A) 48 kg 136 mm 890x430x1540

7XU022001

3200

2500/3800

0/30

1

4500

3600/5400

0/20

1

5800

4600/7000

0/25

1

9000

7200/10800

0/23

2

12000

9500/14500

0/29

2

Piston

260

53

Piston

350

56

Piston

350

56

Piston

400

56

Piston

400

56

182 265 350 525 600

1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970 1980x790x1970

7XU022005 7XU022010 7XU022019 7XU022023 7XU022028

Condenser units

Quantity

Weight

Dimensions (WxDxH)

Part number

UC 33 A

Power supply 3N~400 V 7XU031010

UC 53 A

1 1 kg 59 68 mm 885x825x831 885x825x831

7XU031014

UC 73 A UC 103 A UC 73 A UC 103 A

1 1 2 2

93 130 93 130

1141x885x831 1546x885x893 1141x885x831 1546x885x893

7XU031017 7XU031018 2 x 7XU031017 2 x 7XU031018

Linking specifications between indoor and outdoor units

Power supply 3N~400 V

Power cable section

Fuse rating am

Electrical connections

Linking pipes (not supplied)

Max. lenght

Suction pipe diameter

Liquid pipe diameter mm mm m

2 5x2.5

A 3x16

2 5x1.5

45

Inches 1/2”

Inches 3/8”

5x2.5

3x25

5x1.5

45

1/2”

3/8”

5x4

3x25

5x1.5

45

5/8”

1/2”

5x6

3x32

5x1.5

45

3/4”

5/8”

5x10

3x50

6x1.5

45

5/8”

1/2”

5x16

3x63

6x1.5

45

3/4”

5/8”

47

Vertical cabinet units Packaged Split-System Rooftop

XAR XAO

XAO

Vertical water cabinets

6 Cooling Only models from 8 300 to 45 700 W

X 4650 AO*

Indoor unit CX 25*

> Product advantages

Easy installation and maintenance.

Monobloc system.

Operating with mains or recycled water.

Treated air distribution to premises by plenum or duct network.

Adjustable available static pressure.

Thermostat temperature regulation.

Electrical, refrigeration and thermal protection devices.

Electric heating (accessory).

Hot water coil battery heating (accessory).

”All Seasons” system (Cooling mode operation down to outdoor temperatures of -10° C).

Remote fault reporting (accessory).

Plenum, duct flanges (accessory).

Electrical accessories

Electric heating 1~230 V

CX 25

Capacity (W) 5490

Part nbr 7ACEL0017

Electric heating 3N~400 V Capacity (W) 5490

Part nbr 7ACEL0018

Hot water heating (water 90/80 °C) Capacity (W) -

Confirm left or right side outlet Part nbr -

Combined ON/OFF switch and room thermostat (1) Part nbr 7ACEL0030

”High Ventilation” Part nbr 7ACVF0025

Sum heating resistance Part nbr 7ACEL0027

Part nbr Remote fault reporting kit

Body work accessories

Air distribution duct frame Part nbr -

CX 25

Total rear air intake duct frame

Front air distribution plenum

Part nbr

Part nbr

-

7ACVF0112

New air intake

(1) Combined to be mounted in ambiance.

* Switch assembly to be fitted in the room.

Part nbr -

-

-

X 1100 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AO

-

-

-

-

-

-

-

-

9000

7ACEL0042

12000

7ACEL0043

18000

7ACEL0057

22500

7ACEL0058

37500

7ACEL0116

15500

7ACFH0062

7ACEL0041

7ACVF0023

7ACEL0029

-

29700

7ACFH0063

7ACEL0041

7ACVF0024 included

-

38500

7ACFH0064

7ACEL0032

-

-

7ACEL0072

50000

7ACFH0118

7ACEL0032

-

-

7ACEL0072

77000

7ACFH0180

7ACEL0032

-

-

7ACEL0071

X 1100 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AO

7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052

7ACVF0041

7ACVF0105

7ACVF0047

7ACVF0104

7ACVF0106

7ACVF0047

-

7ACVF0108

-

-

7ACVF0109

-

-

7ACVF0110

-

48

XAO

XAO Series

Cooling capacity

Power Input

EER

CX 25 kW 8.30

kW 2.55

kW 3.26

X 1100 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AO

11.6

3.8

3.05

18.5

5.5

3.36

23.6

7.115

3.31

32

9.75

3.28

45.7

13.9

3.29

Cooling circuit

Compressor type

Noise level (Pressure NS)

Air distribution plenum: height

Weight

Dimensions (WxDxH)

Aeraulic characteristics

- Nominal air flow

- Air flow range (min/max)

- Available static pressure (min/max)

Hydraulic characteristics

- Waste water Flow

Pressure drop

- Recycled water Flow

Pressure drop

1

Piston dB(A) 50 mm 300 kg 125 mm 800x407x1280 m m 3

1~230V With pressostatic water valve

3N~400V With pressostatic water valve

3N~400V Without pressostatic water valve

3 /h 1500

/h 1160/1750 daPa 0/8 m 3 /h 0.37

kPa 25 m 3 /h 1.36

kPa 180

-

7XU012001

7XU012002

-

-

1

Piston

52

220

151

890x430x1540

2000

1500/2500

0/20

0.58

22

2.1

50

7XU012004

1 1 1 2

Piston

55

260

199

Piston

58

350

305

Piston

64

350

380

Piston

60

400

565

1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970

3200

2500/3800

0/30

0.92

18

3.4

70

-

-

7XU012008

-

4500

3600/5400

0/20

1.45

42

4.3

60

7XU012016

7XU012013

-

5800

4600/7000

0/25

2

40

5.8

40

7XU012023

7XU012015

-

9000

7200/10800

0/23

2.8

18

8.3

56

7XU012024

7XU012017

Linking specifications between indoor and outdoor units

Power supply 1~230V

Power cable section

Fuse rating am mm 2 3x2.5

A 16

Power supply 3N~400V

Power cable section

Fuse rating am mm 2 5x1.5

A 3x10

-

-

5x1.5

3x12

-

-

5x1.5

3x20

-

-

5x1.5

3x25

-

-

5x1.5

3x32

-

-

5x1.5

3x50

49

Vertical cabinet units Packaged Split-System Rooftop

DK/DN

DK/DN

Packaged Split-System

11 Cooling Only models from 12 000 to 83 000 W

11 Heat Pump models from 12 400 to 83 800 W

Indoor unit DK 125

Outdoor units DN 405 to 605

DK 205 to 605

> Product advantages

Indoor centrifugal fan units for duct network connection.

Multi-position architecture for horizontal or vertical mounting (depending on models).

Versions with factory-fitted ”All Seasons” kit

(Cooling mode operation down to outdoor temperatures of -10° C).

Outdoor Helicoidal fan units.

Frame and air filter supplied.

CAC Controller: Microprocessor system control and management.

Scroll compressor.

Phase controller.

Electric heating (accessory).

Centralised regulation with RCW2 remote control

(accessory).

Remote control RCW2

Part number 7ACEL1212

Accessories

Electric heating

DK-V 125 DK-V 155 185 205 255 305 405 505 & 605 755 & 905

Capacity (W) 9000 10500 12000 12000 18000 18000 21000 30000 30000

Part number 7ACEL1208 7ACEL1209 7ACEL1185 7ACEL1186 7ACEL1189 7ACEL1176 7ACEL1177 7ACEL1178 7ACEL1340

50

DK/DN

DK/DN Series

125 155 185 205 255 305 405 505 605 755 905

125 RC 155 RC 185 RC 205 RC 255 RC 305 RC 405 RC 505 RC 605 RC 755 RC 905 RC

Cooling capacity kW 12

Power Input kW 4.9

EER 2.4

Outdoor temperature operating limits

14.5

5.8

2.5

17.5

6.9

2.5

19.1

7.1

2.69

22

8.3

2.65

28.1

36.5

11.5

14.3

2.44

2.55

10/46°C Dry Bulb

45.5

17.1

2.66

56.6

22.8

2.48

69.1

24.2

2.85

83

29.7

2.79

Heating Capacity

Power Input

COP

Outdoor temperature operating limits kW 12.4

kW 4.8

2.6

15.7

5.8

2.7

18

6.4

2.8

19.1

6.4

2.98

21.8

7

3.11

27.3

36.5

8.0

3.41

12.1

3.02

-10/19°C Dry Bulb

43.8

14.1

3.11

57.1

20

2.86

71

23.8

3

83.8

29.2

2.9

Indoor units DK

Mounting

Nominal air flow

Min./ max air flow

Available static pressure (min/max)

Nominal acoustic capacity

Weight

Dimensions (WxDxH)

Part number

DK-V 125 DK-V 155 DK 185 DK 205 DK 255 DK 305 DK 405 DK 505 DK 605 DK 755 DK 905

H. ou V.

H. ou V.

Horiz.

Horiz.

Horiz.

Horiz.

Horiz.

Horiz.

Horiz.

Horiz.

Horiz.

m 3 /h 2100 2850 3500 4500 4680 5760 7560 9360 9720 12000 14300 m 3 /h 1600/ 2300/ 2800/ 3600/ 3800/ 4600/ 6000/ 7500/ 7780/ 9600/ 11440/

2400 3100 3900 5000 5100 6300 8200 10300 11000 13200 15730 daPa 0/18 0/11 0/20 2/21 0/21 0/12 0/14 3/19 7/20 5/33 4/46 dB(A) 69 kg 69

72

77

76

98

82

98

82

100

78

150

81

160

80

205

81

209

84

266

88

282 mm 1050x 1250x 1350x 1350x 1350x 1690x 1690x 2100x 2100x 2208x 2208x

890x 890x 745x 1060x 1060x 991x 991x 1064x 1 064x 910x 910x

350 350 400 400 400 676 676 704 704 795 945

Power supply 3N~400 V 7SP051152 7SP051151 7SP051069 7SP051141 7SP051142 7SP051143 7SP051144 7SP051145 7SP051146 7SP051122 7SP051123

Outdoor units DN

Acoustic power (HS)

Compressor type

Number of fan

Weight

Dimensions (WxDxH)

DN 125 DN 155 DN 185 DN 205 DN 255 DN 305 DN 405 DN 505 DN 605 DN 755 DN 905

DN 125RC DN 155RC DN 185RC DN 205RC DN 255RC DN 305RC DN 405RC DN 505RC DN 605RC DN 755RC DN 905RC dB(A) 80 81 78 78 81 82 82 84 87 87 87

Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll

1 kg 140

1

150

1

164

1

164

1

164

1

187

2

317

2

378

2

405

2

559

2

592 mm 746x

746x

909

900x

800x

900x

800x

1060 1060

900x

800x

900x

800x

1060 1060

1003x 1708x 1708x 1708x 2213x 2213x

1003x 1123x 1123x 1123x 1345x 1345x

1094 972 1171 1171 1304 1454

Power supply 3N~400 V 7SP111059 7SP111050 7SP111051 7SP112001 7SP112002 7SP112003 7SP112004 7SP112005 7SP112006 7SP112187 7SP112189

Power supply 3N~400 V 7SP111060 7SP111052 7SP111053 7SP112007 7SP112008 7SP112009 7SP112010 7SP112011 7SP112012 7SP112188 7SP112190

Part number

Part number

Linking specifications between indoor and outdoor units

Power supply 3N~400V

Power cable section

Fuse rating am

Electrical connections

Linking pipes

Max. lenght

Max. height

Suction pipe diameter < 20 m

Suction pipe diameter > 20 m

Liquid pipe diameter < 20 m

Liquid pipe diameter > 20 m mm 2 5x2.5

5x4 5x4 5x4 5x4 5x6 5x10 5x16 5x16 5x25 5x35 mm

A 3x16

2

3x20 3x25 3x25 3x25 3x32 3x40 3x50 3x63 3x63 3x80

6x1.5

6x1.5

4x1.5

4x1.5

4x1.5

4x1.5

4x1.5

4x1.5

4x1.5

4x1.5

4x2.5

m 50 m 50

Inches 3/4”

Inches 3/4”

Inches 1/2”

Inches 1/2”

50

50

7/8”

7/8”

1/2”

1/2”

50

50

7/8”

7/8”

5/8”

5/8”

30

15

30

15

30

15

1-1/8” 1-1/8” 7/8”

30

15

7/8”

1-1/8” 1-1/8” 1-1/8” 7/8”

1/2”

5/8”

1/2”

5/8”

5/8”

5/8”

1/2”

5/8”

30

15

7/8”

7/8”

1/2”

5/8”

30

15

30

15

30

15

1-1/8” 1-3/8” 1-3/8”

(< 10 m)

1-1/8” 1-3/8” 1-3/8”

(< 10 m)

1/2”

5/8”

5/8”

5/8”

5/8”

5/8”

51

Vertical cabinet units Packaged Split-System Rooftop

HA

HA

Rooftop units

6 Cooling Only models from 10 100 to 27 900 W

6 Heat Pump models from 10 400 to 28 500 W

HA unit

> Product advantages

Outdoor installation

Air intake and distribution orifices for connection to a duct network.

CAC Controller: Microprocessor system control and management.

RCW 2 wall mounted remote control or dry contact control (accessory).

Electric heating resistance battery for duct installation (accessory).

Accessories HA 35

Electric heating (1) Capacity (W) 6000

Part number 7ACEL1216

(1) Installed inside ducting, inside the building.

Air filter (air intake)

HA 35

Part number 7ACVF0145

52

HA 43 et 50

9000

7ACEL1217

Remote control RCW2

Part number 7ACEL1212

12000

7ACEL1219

HA 50, 60, 85 & 95

HA 43, 50 & 60

7ACVF0146

HA 85

7ACVF0147

HA 95

7ACVF0148

HA

HA Series

Cooling capacity

Power Input

EER

Outdoor temperature operating limits

Heating Capacity

Power Input

COP

Outdoor temperature operating limits

HA 35 HA 43 HA 50 HA 60 HA 85 HA 95

HA 35 RC HA 43 RC HA 50 RC HA 60 RC HA 85 RC HA 95 RC kW 10.1

kW 3.7

2.73

13

5.1

2.55

14.5

6.01

2.41

18.3

7.5

2.44

15/46°C Dry Bulb

23.2

9.05

2.56

27.9

10.7

2.61

kW 10.4

kW 3.3

3.15

12.8

4.2

3.05

14.8

4.3

3.44

18.4

5.9

3.12

-10/24°C Dry Bulb

22.2

7.6

2.92

28.5

8.5

3.35

Air flow

- Nominal

- Minimal / Maximal

Available static pressure

- Minimal / Maximal

Acoustic pressure

- Indoor

- Outdoor m m

3

3

/h

/h daPa

1 980

1585/2375

10/15 dB(A) 68 dB(A) 80

2 520

2020/3020

0/28

70

82

Compressor type

Weight

Dimensions (WxDxH)

Part number

Part number

Reciprocating kg 140

Power supply 3N~400 V 7HL022001

Power supply 3N~400 V 7HL022007

Reciprocating

197 mm 1095x1150x695 1325x1325x750

7HL022002

7HL022008

3 060

2450/3675

15/26

78

87

Reciprocating

210

1325x1325x750

7HL022003

7HL022009

3 600

2880/4320

13/22

71

83

Reciprocating

216

1325x1325x750

7HL022004

7HL022010

4 680

3745/5615

12/23

71

83

Reciprocating

265

1325x1325x980

7HL022005

7HL022011

5 760

4610/6915

10/12

72

83

Reciprocating

310

1325x1325x1200

7HL022006

7HL022012

Power supply 3N~400V

Power cable section

Fuse rating am

5x2.5

3x20

5x2.5

3x25

5x2.5

3x25

5x2.5

3x32

5x4

3x32

5x6

3x32

53

CHILLED WATER

& HEAT PUMP

RANGE

54

NEW 2007

VC AQU@FAN (fan-convectors)

REGULATION AQU@NET

AQL/AQH (aqu@logic)

CWP (heat pump)

>

Technological, ecological and adaptable

With a capacity ranging from 1 kW to 90 kW, the Airwell Chilled Water and Heat Pump Range is one of the most competitive of the market. Its configurations, perfectly adapted to air/water, water/water, helical or centrifugal requirements, can supply all types of terminal: fan convectors; wall-mounted; cassette-mounted, duct-mounted for residential tertiary areas.

Fanconvectors p.56

Aqu@net p.60

Cassettes p.62

Ducted/ wall units p.64

Air/water chillers p.66

Aqu@logic p.68

Air/water heat pump p.70

55

Fanconvectors Aqu@net Cassettes Ducted

Wall units

Air/water chillers

Aqu@logic Air/water heat pump

NEW AQU@FAN

2 pipes

AQU@FAN

4 pipes

2 PIPES AQU@FAN

Fan-convectors

18 models from 1 100 to 13 900 W - 4 Versions

AQU@FAN AHC AQU@FAN AWC

> Product advantages

Ease of installation.

Streamlined design and elaborate finish enabling harmonious integration.

Air flow rate between 150 and 1500 m 3 /h.

Series of 2 pipes, 2 pipes/2 wires and 4 pipes.

4 versions, lightened, on chassis, flush-mountable,

Ceiling fixture, on chassis, flush-mountable.

5-speed motor.

Very low operating sound levels.

Aquanet electronic regulation as an accessory.

Accessories

W4G1: Regulation valve 1 valve-4 ways for AWC/AWN for AHC/AHN

W4G2: Regulation valve 2 valves-4 ways for AWC/AWN for AHC/AHN

Sizes

10 20 30 40 50 60 70 80 90

Part number 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0367 7ACFH0367 7ACFH0367

Part number 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0365 7ACFH0365 7ACFH0365

Part number 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0368 7ACFH0368 7ACFH0368

Part number 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0366 7ACFH0366 7ACFH0366

ELECTROMECHANICAL REMOTE CONTROL (EXCEPT AWC VERSION)

TRM VP: Wall mounted, on/off, winter/summer 3 fan speed, control on valve

TRM-FA: Wall mounted, on/off, winter/summer 3 fan speed, control on fan

CMVM: Manual fan speed selector (4 levels) Part number 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276

MP: Floor fixing brackets for AWC for AWC for AWN

BAC: Auxiliary drain tray

PRC27: Condensate pump AHN

MPG: Air Intake Grill between feets for AWC & AHC

Part number 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116

Part number 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117

Part number 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118

Part number 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360

Part number 7ACTL0119 7ACTL0187 7ACTL0188 7ACTL0189 7ACTL0190 7ACTL0191 7ACTL0192 7ACTL0193

56

2 PIPES AQU@FAN

2 pipes AQU@FAN Series

Cooling Capacity (HS/NS/LS)

Water flow (HS/NS/LS)

Head losses (HS/NS/LS)

Heating capacity (HS/NS/LS)

Water flow (HS/NS/LS)

Head losses (HS/NS/LS)

1030 2030 3030 4030 5030 6030 7030 8030 9030 kW 1.1/0.95/0.7 2/1.6/1.1

2.4/2/1.5

3.5/2.6/2.2

5/3.3/2.5

5.7/4.4/3.4

6.8/5.6/4 9/6.6/4.7

10.7/9/6.4

l/h 194/162/122 kPa 19/13/8

346/270/187

43/28/15

418/367/263

16/12/7

594/450/375

32.5/20/14

861/573/429

29/14/8

983/753/583

42/26/16

1174/965/673

22/16/8

1548/1142/814

39/23/12

1840/1548/1102

38/28/15 kW 1.6/1.3/0.9

2.7/2.1/1.3

3.4/2.6/1.7

4.6/3.5/2.7

6/4.2/3.2

l/h 194/162/122 kPa 16/11/7

345/270/188

37/23/12

417/367/263

13/11/6

594/450/374

28/17/12

861/572/428

24/12/7

7.4/5.2/4

983/752/583

35/22/14

8.4/6.9/5 11.3/8.4/5.9

13.9/11.5/7.5

1173/965/673 1548/1141/814 1839/1548/1101

19/13/7 33/19/10 33/24/13

Air flow (HS/NS/LS)

Acoustic pressure (HS/NS/LS) m 3 /h 166/126/90 dB(A) 40/33/25

AWC Serie - Vertical Console Units with Cabinet

Weight

Dimensions (WxDxH) kg mm -

292/205/122

45/35/26

374/267/167

48/40/29

524/354/272

44/34/29

677/434/307

47/36/29

843/598/431

53/44/34

984/735/502

53/46/38

1266/859/612

58/48/41

1598/1218/719

62/58/45

20 23 30 35 39 42 50 56

768x231x478 953x231x478 1138x231x478 1323x231x478 1508x231x478 1323x231x578 1508x231x578 1693x231x578

Part number 70G031577 70G031579 70G031581 70G031583 70G031585 70G031587 70G031589 70G031591

AWN Serie - Vertical Concealed Units without Cabinet

Weight

Dimensions (WxDxH) kg 11 14 16 23 27 30 34 41 46 mm 515x220x430 655x220x430 840x220x430 1025x220x430 1210x220x430 1395x220x430 1210x220x530 1395x220x530 1580x220x530

Part number 70G031593 70G031595 70G031597 70G031599 70G031601 70G031603 70G031605 70G031607 70G031609

AHC Serie - Ceiling Exposed Units with Cabinet

Weight

Dimensions (WxDxH) kg mm -

20

768x231x478

23

953x231x478

30

1138x231x478

35

1323x231x478

39

1508x231x478

42

1323x231x578

50

1508x231x578

56

1693x231x578

Part number 70G031611 70G031613 70G031615 70G031617 70G031619 70G031621 70G031623 70G031625

AHN Serie - Ceiling Concealed Units without Cabinet

Weight

Dimensions (WxDxH) kg 11 14 16 23 27 30 34 41 46 mm 572x220x430 712x220x430 897x220x430 1082x220x430 1267x220x430 1452x220x430 1267x220x530 1452x220x530 1637x220x530

Part number 70G031627 70G031629 70G031631 70G031633 70G031635 70G031637 70G031639 70G031641 70G031643

2 pipes/2 wires AQU@FAN Series 1030 E 2030 E 3030 E 4030 E 5030 E 6030 E 7030 E 8030 E 9030 E

Cooling Capacity (HS/NS/LS)

Water flow (HS/NS/LS)

Head losses (HS/NS/LS) kW 1.1/0.95/0.7 2/1.6/1.1

2.4/2/1.5

3.5/2.6/2.2

5/3.3/2.5

5.7/4.4/3.4

6.8/5.6/4 9/6.6/4.7

10.7/9/6.4

l/h 194/162/122 kPa 19/13/8

346/270/187

43/28/15

418/367/263

16/12/7

594/450/375

32.5/20/14

861/573/429

29/14/8

983/753/583

42/26/16

1174/965/673

22/16/8

1548/1142/814

39/23/12

1840/1548/1102

38/28/15

Heating capacity (HS/NS/LS)

Water flow (HS/NS/LS)

Head losses (HS/NS/LS) kW 1.6/1.3/0.9

l/h 194/162/122 kPa 16/11/7

2.7/2.1/1.3

3.4/2.6/1.7

345/270/188 417/367/263

37/23/12 13/11/6

4.6/3.5/2.7

6/4.2/3.2

594/450/374 861/572/428

28/17/12 24/12/7

7.4/5.2/4

983/752/583

35/22/14

8.4/6.9/5 11.3/8.4/5.9

13.9/11.5/7.5

1173/965/673 1548/1141/814 1839/1548/1101

19/13/7 33/19/10 33/24/13

Electrical heating

Air flow (HS/NS/LS)

Acoustic pressure (HS/NS/LS)

W 500 m 3 /h 166/126/90 dB(A) 40/33/25

AWC Serie - Vertical Console Units with Cabinet

Weight

Dimensions (WxDxH) kg mm -

750

292/205/122

1200

374/267/167

45/35/26 48/40/29

1500

524/354/272

2000

677/434/307

44/34/29 47/36/29

2400

843/598/431

53/44/34

3000 3600 4500

984/735/502 1266/859/612 1598/1218/719

53/46/38 58/48/41 62/58/45

20 23 30 35 39 42 50 56

768x231x478 953x231x478 1138x231x478 1323x231x478 1508x231x478 1323x231x578 1508x231x578 1693x231x578

Part number 7OG031645 7OG031646 7OG031647 7OG031648 7OG031649 7OG031650 7OG031651 7OG031652

AWN Serie - Vertical Concealed Units without Cabinet

Weight

Dimensions (WxDxH) kg 11 14 16 23 27 30 34 41 46 mm 515x220x430 655x220x430 840x220x430 1025x220x430 1210x220x430 1395x220x430 1210x220x530 1395x220x530 1580x220x530

Part number 7OG031653 7OG031654 7OG031655 7OG031656 7OG031657 7OG031658 7OG031659 7OG031660 7OG031661

AHC Serie - Ceiling Exposed Units with Cabinet

Weight

Dimensions (WxDxH) kg mm -

20

768x231x478

23

953x231x478

30

1138x231x478

35

1323x231x478

39

1508x231x478

42

1323x231x578

50

1508x231x578

56

1693x231x578

Part number 7OG031662 7OG031663 7OG031664 7OG031665 7OG031666 7OG031667 7OG031668 7OG031669

AHN Serie - Ceiling Concealed Units without Cabinet

Weight

Dimensions (WxDxH) kg 11 14 16 23 27 30 34 41 46 mm 572x220x430 712x220x430 897x220x430 1082x220x430 1267x220x430 1452x220x430 1267x220x530 1452x220x530 1637x220x530

Part number 7OG031670 7OG031671 7OG031672 7OG031673 7OG031674 7OG031675 7OG031676 7OG031677 7OG031678

57

Fanconvectors Aqu@net Cassettes Ducted

Wall units

Air/water chillers

Aqu@logic Air/water heat pump

NEW AQU@FAN

2 pipes

AQU@FAN

4 pipes

4 PIPES AQU@FAN

Fan-convectors

9 models from 1 100 to 14 011 W - 4 Versions

AQU@FAN AHN AQU@FAN AWN

> Product advantages

Ease of installation.

Streamlined design and elaborate finish enabling harmonious integration.

Air flow rate between 150 and 1500 m 3 /h.

Series of 2 pipes, 2 pipes/2 wires and 4 pipes.

4 versions, lightened, on chassis, flush-mountable,

Ceiling fixture, on chassis, flush-mountable.

5-speed motor.

Very low operating sound levels.

Aquanet electronic regulation as an accessory.

Accessories

W4G1: Regulation valve 1 valve-4 ways for AWC/AWN for AHC/AHN

W4G2: Regulation valve 2 valves-4 ways for AWC/AWN for AHC/AHN

Sizes

10 20 30 40 50 60 70 80 90

Part number 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0363 7ACFH0367 7ACFH0367 7ACFH0367

Part number 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0361 7ACFH0365 7ACFH0365 7ACFH0365

Part number 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0364 7ACFH0368 7ACFH0368 7ACFH0368

Part number 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0362 7ACFH0366 7ACFH0366 7ACFH0366

ELECTROMECHANICAL REMOTE CONTROL (EXCEPT AWC VERSION)

TRM VP: Wall mounted, on/off, winter/summer 3 fan speed, control on valve

TRM-FA: Wall mounted, on/off, winter/summer 3 fan speed, control on fan

CMVM: Manual fan speed selector (4 levels) Part number 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276 7ACEL1276

MP: Floor fixing brackets for AWC for AWC for AWN

BAC: Auxiliary drain tray

PRC27: Condensate pump AHN

MPG: Air Intake Grill between feets for AWC & AHC

Part number 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116 7ACTL0116

Part number 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117 7ACTL0117

Part number 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118 7ACTL0118

Part number 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360 7ACTL0360

Part number 7ACTL0119 7ACTL0187 7ACTL0188 7ACTL0189 7ACTL0190 7ACTL0191 7ACTL0192 7ACTL0193

58

AQU@FAN 4 PIPES

4 pipes AQU@FAN Series

Cooling Capacity (HS/NS/LS)

Water flow (HS/NS/LS)

Head losses (HS/NS/LS)

Heating capacity (HS/NS/LS)

Water flow (HS/NS/LS)

Head losses (HS/NS/LS)

1031 2031 3031 4031 5031 6031 7031 8031 9031 kW 1.1/0.9/0.7

1.97/1.5/1.1

2.4/2.1/1.5

3.4/2.5/2.1

4.9/3.2/2.4

5.6/4.3/3.3

6.7/5.5/3.8

8.8/6.5/4.6

10.5/8.8/6.2

l/h 191/158/119 kPa 18/13/8

338/266/184

42/27/14

411/356/256

15/12/7

583/439/367

31/19/14

839/558/418

27/13/8

961/735/569

40/25/16

1145/940/655

21/15/8

1516/1113/792

38/22/12

1804/1512/1069

37/27/14 kW 1.4/1.25/1 2.5/2.1/1.5

3.3/2.8/2.2

4.5/3.7/3.2

6.3/4.9/3.9

6.6/5.6/4.6

7/6.2/4.7

11.5/9.4/6.7 14/12.3/8.9

l/h 126/110/88 kPa 2/2/1

216/184/129

6/4/2

292/246/189

13/9/6

398/327/281

25/17/13

550/428/340

50/32/21

583/493/403

15/11/8

620/541/414

14/11/7

1014/828/592

48/33/18

1229/1079/783

73/57/32

Air flow (HS/NS/LS)

Acoustic pressure (HS/NS/LS) m 3 /h 161/122/87 dB(A) 40/34/26

AWC Serie - Vertical Console Units with Cabinet

Weight

Dimensions (WxDxH) kg mm -

283/224/158

45/36/27

362/258/162

48/41/30

508/343/263

44/34/29

656/420/297

47/37/29

817/579/417

53/46/35

953/712/486

53/46/38

1226/832/592

58/49/41

1547/1180/696

62/58/45

20 23 30 35 39 42 50 56

768x231x478 953x231x478 1138x231x478 1323x231x478 1508x231x478 1323x231x578 1508x231x578 1693x231x578

Part number 7OG031578 7OG031580 7OG031582 7OG031584 7OG031586 7OG031588 7OG031590 7OG031592

AWN Serie - Vertical Concealed Units without Cabinet

Weight

Dimensions (WxDxH) kg 11 14 16 23 27 30 34 41 46 mm 515x220x430 655x220x430 840x220x430 1025x220x430 1210x220x430 1395x220x430 1210x220x530 1395x220x530 1580x220x530

Part number 70G031594 70G031596 70G031598 70G031600 70G031602 70G031604 70G031606 70G031608 70G031610

AHC Serie - Ceiling Exposed Units with Cabinet

Weight

Dimensions (WxDxH) kg mm -

20

768x231x478

23

953x231x478

30

1138x231x478

35

1323x231x478

39

1508x231x478

42

1323x231x578

50

1508x231x578

56

1693x231x578

Part number 7OG031612 7OG031614 7OG031616 7OG031618 7OG031620 7OG031622 7OG031624 7OG031626

AHN Serie - Ceiling Concealed Units without Cabinet

Weight

Dimensions (WxDxH) kg 11 14 16 23 27 30 34 41 46 mm 572x220x430 712x220x430 897x220x430 1082x220x430 1267x220x430 1452x220x430 1267x220x530 1452x220x530 1637x220x530

Part number 70G031628 70G031630 70G031632 70G031634 70G031636 70G031638 70G031640 70G031642 70G031644

59

Fanconvectors

Aqu@net Cassettes Ducted

Wall units

Air/water chillers

Aqu@logic Air/water heat pump

AQU@NET

AQU@NET

Central regulation station

> Product advantages

Window contact.

Multiple configuration.

Compliant with RT2000.

µBMS mini central regulation station

The µBMS surveillance central station was designed to control operation and to monitor the temperature of individual systems, but also average sized heating, ventilation and air conditioning systems.

It is simple to use and efficiently manages from 1 to 15 different temperature zones.

By simple programming, the user can change the set temperature values of heating and cooling modes, select the ventilation speed for each of the areas monitored by his mini surveillance central station.

This central station makes it possible to individually monitor the following functions in each of the zones by means of a single RS 385 communication bus (2 twisted and shielded wires):

• A programming including on/off or sleep, the time and day of the week, the operating mode, the ventilation speed (Lo, Me, Hi, Auto), and temperature settings.

This programming selects the time ranges.

- Either individually (for each zone) for 2 time ranges.

- Or globally (for all zones) for 2 time ranges.

• A comfort (occupancy)/economy (vacant) function.

• An anti-frost function for heating mode.

• A ventilation flap control function.

Electronic controls

Type of device

Wall-mounted RCL (kit)

Device mounted RCL

AWC

AWN

AHC

-

Electronic regulators

AquaNet system A = 2 Pipes

AquaNet system B = 2 Reversible Pipes (with pipe probe) (4-way valve mandatory)

AquaNet system C = 2 Pipes/2 Wires (2 electrical stages) (1)

AquaNet system D = 2 Reversible Pipes + Additional electric power (3 Heating stages : heating valve + 2 electric stages) (1)

(4-way valve mandatory)

AquaNet system E = 4 Pipes

(1) Second heating stage with electric battery on option, see tarif.

AHN

-

Regulation and communication accessories

Auxiliary board for communication via NIU bus (factory mounted)

µBMS central surveillance station (100 units and 15 zones)

Airconet@niu control board

ATTENTION: products configured per requirements. Specify the type of system desired in the order.

(A, B, C, D, E), the type of RCL control desired (built-in or remoted), the accessories.

60

AQU@NET

ELECTRONIC REGULATION INFORMING ON WATER AND AIR

RCL control

(built into the unit or remoted)

Electronic regulation for the Aqu@Net was specially developed for fan convectors of the lightened, ceiling fixture or cassette type, with total recycled air for applications relating to 2 cooling pipes alone, 2 heating pipes alone,

2 pipes/2 wires, 2 reversible pipes with or without additional electric power and 4 pipes. It consists of an FCC regulator built into the fan convector and an RCL control that can be installed on option on our range of lightened type fan convectors.

Aqu@Net is a new generation of regulation units operating with a proprietary communication bus by means of an additional board that is very simple to install and a supervision central station called µBMS. For small systems, this regulation also makes it possible to very easily set up a master/slave wire link network to monitor up to 15 devices with a single RCL control.

The Aqu@Net electronic regulation was designed to provide an excellent trade-off between cost (thermal valve for integral proportional regulation), ergonomics and performance.

It is compatible with the µBMS supervision central station and communicates over the proprietary bus; it can however also operate without the supervision central station. The Aqu@Net regulation enables adaptation to the following air conditioner models:

MODEL A : For fan convectors with 2 heating or cooling pipes alone with manual changeover.

MODEL B : For fan convectors with 2 reversible pipes with automatic changeover (pipe probe).

MODEL C : For fan convectors with 2 pipes/2 wires.

MODEL D : For fan convectors with 2 reversible pipes with automatic changeover (pipe probe) and additional electric power for heating and cooling.

MODEL E : For fan convectors with 4 pipes.

FCC regulator

(built into the unit)

The Aqu@Net regulation fully controls operation of the fan convector, by switching on or shutting down as a function of the temperature setting, automatic or manual engagement of the ventilation speeds, control of the heating or cooling valve in timed mode proportional to the PI algorithm, and an integral proportional control on the two electric heating stages.

In its standard configuration, the Aqu@Net regulation integrates additional functions for an individual control or for controlling several zones of fan convectors:

• comfort function (occupancy) / economy function (vacant),

• window contact with activation of anti-frost mode,

• keypad locking,

• operation as master/slave of up to 15 units, from a single remote control.

Simple-to-use regulation system, no programming of regulators being necessary.

System easy to install, the Aqu@Net regulation is installed, wired and configured in the factory.

Individual item regulation system, simple to use, for one zone or multiple zones via the communication bus.

Upgradable regulation system, steered by a mini supervision central station ensuring automatic and weekly management of operating time ranges, temperature settings for each area, and this for 15 different zones.

> Product advantages

Plug and play.

Factory wired.

Possibility of Master/Slave operation.

Occupancy/vacant mode management.

Additional board

Aqu@net network architecture

TEMP

MODE

NIGHT

SWING

SWING

TIMER

SET

CLEAR

+

HOUR

-

Mini supervision central station

RS485 bus up to

100 units

FCC FCC FCC up to

15 units up to

15 units up to

15 units

RCL RCL RCL

61

Fanconvectors

Aqu@net Cassettes Ducted

Wall units

Air/water chillers

Aqu@logic Air/water heat pump

K OG

2 pipes

K OG

4 pipes

2 & 4 PIPES K OG

Chilled Water Cassettes

5 models - 2 pipes from 2 330 to 10 200 W

4 models - 4 pipes from 2 200 to 10 600 W

K OG 9/12/18

> Product benefits

Designed for suspended ceiling integration.

600 x 600 and 600 x 1200 formats (30 and 45 models).

Low built-in height: 287 mm.

Direct access to electrical connections on sliding chassis.

Integrated valves and electrical connections.

K OG 30/45

New air intake.

Air distribution to a separate room.

Integrated condensate drainage lift pump.

Infrared remote control version with valve and changeover.

Solid ceiling frame (accessory).

2 Pipes Accessories K 9 OG

Heating/Cooling thermostat Part nbr 7ACEL1161

Manual ON/OFF- 3 fan speed (KOG 2T CH AV version)

K 12 OG

7ACEL1161

K 18 OG

7ACEL1161

Heating/Cooling thermostat Part nbr 7ACEL1386 7ACEL1386

Manual ON/OFF- 3 fan speed (KOG 2T AV version) with sonde of change over

Heating/Cooling thermostat Part nbr 7ACEL1373

Manual ON/OFF- 3 fan speed - without valve (KOG 2T SV version)

7ACEL1386

Heating/Cooling thermostat Part nbr 7ACEL1388 7ACEL1388

Manual ON/OFF- 3 fan speed (KOG 2T CH AV version) change over sensor and electric heating relay

7ACEL1388

7ACEL1373 7ACEL1373

Special Frame for solid ceilings Part nbr 7ACVF0091 7ACVF0091 7ACVF0091

7ACEL1161

7ACEL1386

7ACEL1388

7ACEL1373

-

K 30 OG

-

K 45 OG

7ACEL1161

7ACEL1386

7ACEL1388

7ACEL1373

Relay kit for chilled water cassettes (4 units) Part nbr 7ACEL1207

3 way heating valve/ 2 pipes + condensate tray Part nbr -

Condensate Part nbr -

7ACEL1207

-

-

7ACEL1207

-

-

7ACEL1207

7ACFH0051

7ACTL0005

7ACEL1207

7ACFH0052

7ACTL0005

4 Pipes Accessories K 9 OG

Heating/Cooling thermostat Part number 7ACEL1161

Manual ON/OFF- 3 fan speed (KOG 4T AV version) with sonde of change over

Special Frame for solid ceilings Part number 7ACVF0091

Relay kit for chilled water cassettes (4 units)

3 way heating valve/ 4 pipes + condensate tray

Condensate (4 pipes)

Part number 7ACEL1207

Part number -

Part number -

K 12 OG K 18 OG K 45 OG

7ACEL1161

-

-

7ACVF0091

7ACEL1207

7ACEL1161

-

-

7ACVF0091

7ACEL1207

7ACEL1161

-

7ACEL1207

7ACFH0122

7ACTL0040

62

2 & 4 PIPES K OG

2 pipes KOG Series

Cooling Capacity

Heating Capacity

Power Input

Electrical Heating (Factory option)

Indoor units

Air flow (LS/NS/HS)

Water flow

Water pressure drop

Acoustic power to 1m (LS/NS/HS)

Weight

Built in casing (WxDxH)

Frame (WxDxH) kW 2.33

K 9 OG kW 3.4

kW 0.06

kW 1.5

m 3 /h 420/460/700 m 3 /h 0.378

kPa 12.5

dB(A) 37/40/50 kg 25 mm 571x571x287 mm 625x625x40

3.5

K 12 OG

4.6

0.08

2.25

420/460/700

0.602

17.5

38/41/51

28

571x571x287

625x625x40

5

K 18 OG

5.9

0.11

2.7

460/515/760

0.86

15

44/49/57

29

571x571x287

625x625x40

K 30 OG

6.44

8.05

0.20

4.2

K 45 OG

10.2

11.6

0.22

5.4

1100/1350/1550 1000/1250/1630

1.208

1.753

17

51/54/57

23.5

50/54/60

49

1171x571x287

1225x625x40

55

1171x571x287

1225x625x40

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power cable section (without heating) mm

Fuse rating am (without heating)

2 3x1

A 1

Power cable section (with heating)

Fuse rating am (with heating) mm 2 3x1.5

A 10

Version without valve

Part number 1~230 V model

K9 OG 2T SV

7OG051008

Version with valve

Part number

K9 OG 2T AV

1~230 V model 7OG051009

Electrical Heating version without valve

Part number 1~230 V model

K9 OG 2T CH SV

7OG051010

Electrical Heating version with valve

Part number 1~230 V model

K9O G 2T CH AV

7OG051011

Infrared version with valve and change over K9 OG 2T IR AV

Part number 1~230 V model 7OG101010

4 pipes KOG Series

Cooling Capacity

3x1

1

3x1.5

16

K12 OG 2T SV

7OG051012

3x1

1

3x1.5

16

K18 OG 2T SV

7OG051016

3x1.5

2

3x4

25

K30 OG 2T SV

7SP041036

3x1.5

2

3x2.5

25

K45 OG 2T SV

7SP041037

K12 OG 2T AV

7OG051013

K18 OG 2T AV

7OG051017 -

-

-

-

K12 OG CH 2T SV K18 OG CH 2T SV K30 OG CH 2T SV K45 OG CH 2T SV

7OG051014 7OG051018 7SP041020 7SP041025

K12 OG 2T CH AV K18 OG 2T CH AV -

7OG051015 7OG051019 -

K12 OG 2T IR AV -

7OG101011 -

-

-

K30 OG 2T IR AV K45 OG 2T IR AV

7OG101013 7OG101014 kW 2,2

K 9 OG K 12 OG

3,43

K 18 OG

4,9

K 45 OG

10,6

Heating Capacity

Power Input kW 2,2 kW 0,06

3,2

0,08

4,9

0,11

9,25

0,22

Indoor units

Air flow (LS/NS/HS)

Cold Water flow

Hot Water flow

Water pressure drop

Acoustic power to 1m (LS/NS/HS)

Weight

Built in casing (WxDxH)

Frame (WxDxH) m 3 /h 420/460/700 m 3 /h 0,378 m 3 /h 0,19 kPa 12 dB(A) 37/40/50 kg 25 mm 571x571x287 mm 625x625x40

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Fuse rating am

Linking pipes

Suction 4 pipes diameter

Version without valve

Part number

Version with valve

Part number

A 10

Inches 1/2’’

K9 OG 4T SV

1~230 V model 7OG051020

K9 OG 4T AV

1~230 V model 7OG051021

420/460/700

0,59

0,275

17

40/42/52

28

571x571x287

625x625x40

16

1/2’’

K12 OG 4T SV

7OG051022

K12 OG 4T AV

7OG051023

320/460/515/760 1075/1360/1725

0,843 1,825

0,421

17,5

42/48/57

0,49

28,6

48/54/60

29

571x571x287

625x625x40

55

1171x571x287

1225x625x40

16

1/2’’ hot/3/4’’ cold

K18 OG 4T SV

7OG051024

K18 OG 4T AV

7OG051025

-

1/2’’ hot/1’’ cold

K45 OG 4T SV

7SP041024

-

K45 OG 4T AV

63

Fanconvectors

Aqu@net Cassettes Ducted Air/water chillers

Aqu@logic Air/water heat pump

VHF

2 pipes

VHF

Ducted units

4 models - 2 pipes from 3 300 to 11 900 W

VHF

> Product benefits

Indoor units compatible with AIRWELL chilled water production units.

Compact dimensions and low built-in height (231 mm for the VHF 01A model).

Available static pressure.

Designed for suspended ceiling integration with a duct network.

Integrated air intake plenum, 200 mm diameter outlets.

Integrated air distribution plenum, 200 mm diameter outlets.

New air intake, 100 mm diameter.

3 fan (ventilation) speeds.

Low noise levels.

Air filter, G2 (80% gravimetry) reusable synthetic material.

Easy access to electrical and hydraulic connections on the right side of the unit.

Easy air filter access via the underside of the unit.

Electric heating available as a factory-fitted option

(on request): • VHF 01A: 1,000 W

• VHF 05A: 1,500 W

• VHF 10 and 12A: 3,600 W

2 pipes VHF Series

Cooling Capacity

Heating Capacity

Power Input

VHF01A kW 2.9

kW 3.3

kW 0.19

VHF05A

4.9

4.8

0.13

VHF10A

7.4

6.2

0.27

VHF12A

9.4

11.9

0.24

Indoor units

Air flow

Water flow

Water pressure drop

Weight

Dimensions (WxDxH) m 3 /h from 100 to 550 m 3 /h from 300 to 700 m 3 /h from 400 to 1000 m 3 /h from 700 to 1500 m 3 /h m 3 /h 0.5

0.84

1.27

1.63

kPa 17 kg 21 mm 600x695x200

22

46

1062x918x231

44

55

1202x918x253

39

59

1202x918x301

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power cable section

Fuse rating am mm 2 3x1.5

A 1

Part number 1~230 V model - Version without valve 7OG041030

3x1.5

1

7OG041031

3x1.5

2

7OG041032

3x1.5

2

7OG041033

64

Fanconvectors

Aqu@net Cassettes Wall units Air/water chillers

Aqu@logic Air/water heat pump

XLM OG

2 pipes

XLM OG

Chilled Water wall mounted units

4 models - 2 pipes from 3 300 to 11 900 W

XLM OG 18

XLM OG 7/9

> Product benefits

Indoor units compatible with AIRWELL chilled water production units.

Compact and lightweight design for easy installation and maintenance.

Available with or without flow regulation valve.

Hard-wired controls (with or without regulation valve).

2 pipes XLM OG Series

Cooling Capacity

Heating Capacity

Power Input

Electrical Heating kW 1.85

kW 2.25

kW 0.1

kW 1.05

XLM 7 OG

Indoor units

Air flow (LS/NS/HS)

Acoustic power

Water flow

Water pressure drop

Weight

Dimensions (WxDxH) m 3 /h 220/290/360 dB(A) 43/45/49 m 3 /h 0.32

Pa 12 kg 8 mm 815x160x270

Linking specifications between indoor and outdoor units

Power supply

Power cable section

Fuse rating am (without electric heating)

Fuse rating am (with electric heating) mm 2 3x1.5

A 1

A 6

Thermostat version TRM-FA, without valve

Part number

XLM 7 OGSV

1~230 V model 7SP022027

Thermostat version TRM-VP, without valve

Part number

XLM 7 OGAV

1~230 V model 7OG061098

Thermostat version TAE20, electric heating with valve

Part number 1~230 V model

XLM 7 OGAVCH

7OG061013

-

3x1.5

1

XLM 9 OGSV

7SP022028

-

-

XLM 9 OGAV

7OG061099

2.2

3.3

-

0.1

XLM 9 OG

280/370/450

50/52/53

0.38

15

9.5

815x160x270

3.5

4.6

0.2

1.6

XLM 18 OG

600/740/860

52/56/57

0.5

17

14

1115x195x330

3x1.5

2

10

XLM 18 OGSV

7OG061010

XLM 18 OGAV

7OG061100

XLM 18 OGAVCH

7OG061008

65

Fanconvectors

Aqu@net Cassettes Ducted

Wall units

Air/water chillers Aqu@logic Air/water heat pump

MQL/MQH

MQL/MQH

Air/water chillers

7 Cooling Only models from 4 500 to 16 500 W (MQL)

7 Heat Pump models from 5 000 to 18 800 W (MQH)

MQH 04/06/08

MQL 04/06/08

MQH 10/12/15/17

MQL 10/12/15/17

> Product benefits

Single-phase units up to size 10.

Microprocessor controlled operation.

µLTC regulation (self-adapting set temperature point, fan (ventilation) speed control…)

Reduced water volume (3.5 litres/ kW).

Ready to install unit.

3 pump speeds.

Average COP: 4.1.

Average EER: 3.1.

Low noise levels.

Numerous accessories (start-up current draw regulator, low temperature operation kit, buffer tank).

Accessories

MQL 04 MQL 06 MQL 08 MQL 10 MQL 12 MQL 15 MQL 17

MQH 04 MQH 06 MQH 08 MQH 10 MQH 12 MQH 15 MQH 17

Remote control with cable Part number 7ACEL1188 7ACEL1188 7ACEL1188 7ACEL1188 7ACEL1188 7ACEL1188 7ACEL1188

Isolating valve with pressure kit Part number 7ACFH0423

Water filter Part number 7ACFH0278

Water Tank 15 l

Water Tank 30 l

Part number 7ACFH0486

Part number -

7ACFH0423

7ACFH0278

7ACFH0486

-

7ACFH0423

7ACFH0278

7ACFH0486

-

7ACFH0423

7ACFH0278

-

7ACFH0484

7ACFH0423

7ACFH0278

-

7ACFH0484

7ACFH0423

7ACFH0278

-

7ACFH0484

7ACFH0423

7ACFH0278

-

7ACFH0484

Low ambiant kit (- 5 °C)

MQL 04 MQL 06 MQL 08 MQL 10 MQL 12 MQL 15 MQL 17

Part number 7ACFH0475 7ACFH0475 7ACFH0475 7ACFH0475 7ACFH0475 7ACFH0475 7ACFH0475

66

MQL/MQH

MQL/MQH Series

Cooling Capacity kW 4.5

Power Input

EER kW 1.5

3.0

Operating limits outdoor temperature °C

Outlet water temperature °C

MQL 04 MQL 06 MQL 08 MQL 10 MQL 12 MQL 15 MQL 17

MQH 04 MQH 06 MQH 08 MQH 10 MQH 12 MQH 15 MQH 17

5.9

1.9

3.1

8.1

2.7

3.0

10.5

3.3

3.2

10°/ 46°

5°/ 18°

12.1

4.0

3.0

14.9

4.6

3.2

16.5

5.2

3.2

Heating Capacity (1) kW 5

Power Input

COP kW 1.2

4.2

Operating limits outdoor temperature °C

Outlet water temperature °C

6.7

1.6

4.2

9.1

2.6

3.5

10.5

2.8

3.8

-5°/ 15°

30°/ 50°

13.1

3.3

4.0

17.4

3.80

4.6

18.8

4.30

4.4

Static pressure at 5 m

Compressor type

Weight

Dimensions (WxDxH)

Exchanger type

Water circuit links

Inlet

Outlet dB(A) 40

Rotary kg 97 mm 1182x400x905 1182x400x905 1182x400x905 1182x400x1309 1182x400x1309 1182x400x1309 1182x400x1309

Stainless stell plate Stainless stell plate Stainless stell plate Stainless stell plate Stainless stell plate Stainless stell plate Stainless stell plate

Inches 1”

Inches 1”

40

Rotary

104

1”

1”

41

Scroll

110

1”

1”

43

Scroll

153

1”

1”

44

Scroll

158

1”

1”

45

Scroll

160

1”

1”

45

Scroll

166

1”

1”

Linking specifications between indoor and outdoor units

Power supply 1~230 V

Power cable section

Fuse rating am

Power supply 3N~400 V

Power cable section

Fuse rating am mm 2 3x2.5

A 16 mm 2 -

A -

-

-

3x2.5

16

3x4

25

3x4

25

-

-

-

-

-

-

5x2.5

3x16

-

-

-

-

-

-

-

-

Part number 1~230 V model 7OG012170 7OG012171 7OG012172 7OG012132 -

Part nbr 1~230 V model - Avec Softstarter 7OG012178 7OG012179 7OG012180 7OG012144 -

Part number

Part number

3N~400 V model -

1~230 V model 7OG012174

-

7OG012175

7OG012173

7OG012176

7OG012133

7OG012137 -

7OG012134

-

-

-

7OG012135

-

-

-

7OG012136

Part nbr 1~230 V model - Avec Softstarter 7OG012181 7OG012182 7OG012183 7OG012145 -

Part number 3N~400 V model -

(1) Conditions: 7 °C outdoor, 35 °C outlet water.

7OG012177 7OG012138 7OG012139

-

7OG012140

-

7OG012141

67

Fanconvectors

Aqu@net Cassettes Ducted

Wall units

Air/water chillers

Aqu@logic Air/water heat pump

NEW

AQU@LOGIC AQL/AQH

Fluid coolers with condensation by air and reversible air-water heat pumps

9 Cooling Only models from 21 500 to 75 000 W (AQL)

9 Heat Pump models from 24 000 to 87 400 W (AQH)

AQL/AQH

AQH 20 AQH 80

AQH 40

> Product advantages

Choice from 10 sizes.

Compatible with Water Chilled Airwell terminal units and heating-cooling floor.

Tandem Scroll compressor in standard version.

Plug and play design, unit ready to operate.

Self-adapting regulation with ILTC microprocessor.

Power savings.

Low operating sound level.

Brazed plate heat exchanger.

High-performance axial fan with external rotor.

Easy access to components provided by removable panels.

Accessories

Isolating valve

AQL 20 AQL 25 AQL 30 AQL 35 AQL 40 AQL 50 AQL 60 AQL 70 AQL 80

AQH 20 AQH 25 AQH 30 AQH 35 AQH 40 AQH 50 AQH 60 AQH 70 AQH 80

Part number 7ACFH0345 7ACFH0345 7ACFH0345 7ACFH0345 7ACFH0345 7ACFH0345 7ACFH0345 7ACFH0345 7ACFH0345

Additional water tank 112 l Part number 7ACFH0346 7ACFH0346 7ACFH0346 7ACFH0346 -

Additional water tank 224 l Part number 7ACFH0347

-

7ACFH0347

-

-

Additional water tank 294 l Part number -

-

-

-

-

7ACFH0348 7ACFH0348 7ACFH0348

68

AQU@LOGIC

AQL/AQH

AQL/AQH Series

Cooling capacity (2)

Power input with pump

Power input

EER

Outdoor temperature operating limits

Outlet water temperature Min/Max.

Heating capacity (1)

Power input with pump

Power input

COP

Outdoor temperature operating limits

Outlet water temperature Min/Max.

AQL 20 AQL 25 AQL 30 AQL 35 AQL 40 AQL 50 AQL 60 AQL 70 AQL 80

AQH 20 AQH 25 AQH 30 AQH 35 AQH 40 AQH 50 AQH 60 AQH 70 AQH 80 kW 21.5

kW 8.4

kW 7.6

3.0

°C

°C

26

10

9.2

3.0

29.9

11.4

10.6

3.0

34.2

12.2

11.4

2.9

39.5

16.1

15.4

2.9

-10°/ 46°

5°/ 18°

47.9

19.4

18.7

2.6

55.9

23.9

22.8

2.7

67

28.1

27

2.7

75

30.7

29.6

2.7

kW 24 kW 7.2

kW 6.4

3.8

°C

°C

29

8.3

7.5

3.9

34.2

9.5

8.7

3.9

38.3

9.3

8.5

4.5

46.3

13.5

12.7

3.6

-10°/ 20°

25°/ 50°

57.7

16

15.2

3.8

68.9

19.9

18.8

3.7

80.5

23.8

22.7

3.5

87.4

26

24.9

3.5

Air flow max (HS)

Acoustic pressure at 1 m

Compressor type

Water volume

Expansion valve

Water pump m 3 /h 11200 dB(A) 59

Quantity vs capacity reduction stages

Min. power

2/2

% 70

Max. pressure on refrigerant side/ on water side bar 30/10

Anti-freezing heating element W 35 l 1.67

l 5

Weight with pump

Weight without pump

Dimensions (WxDxH)

11200

60

2/2

50

30/10

35

2.2

5

11200

60

2/2

50

30/10

35

2.44

5

11200

61

2/2

50

30/10

35

2.44

5

15500

65

Hermetic Scroll

2/2

45

30/10

35

15500

65

2/2

36

30/10

35

3.44

12

4.33

12

Centrifugal pump monospeed

15500

67

2/2

36

30/10

35

5.33

12

21000

70

2/2

45

30/1030/10

35

6.33

12

21000

70

2/2

50

35

7.10

12 kg 286 kg 271

296

281

306

291

305

290

510

490

585

565

590

570

620

600

640

620 mm 1477x516x1607 1477x516x1607 1477x516x1607 1477x516x1607 1737x1201x1634 1737x1201x1634 2168x1201x1634 2168x1201x1634 2168x1201x1634

Linking specifications between indoor and outdoor units

Power supply 3N~400 V

Power cable section

Fuse rating am

Hydraulic connection

Diameter mm 2 5x6

A 25

Inches 1”1/2

5x10

32

1”1/2

5x10

32

1”1/2

5x10

40

1”1/2

5x16

50

2”

5x16

50

2”

5x25

63

2”

5x25

63

2”

5x25

80

2”

Part nbr Basic model 3N~400 V 7OG021001 7OG021002 7OG021003 7OG021004 7OG021005 7OG021006 7OG021007 7OG021008 7OG021009

Part nbr Pack model with single pump 3N~400 V 7OG021015 7OG021016 7OG021017 7OG021018 7OG021019 7OG021020 7OG021021 7OG021022 7OG021023

Part nbr Basic model 3N~400 V 7OG021029 7OG021030 7OG021031 7OG021032 7OG021033 7OG021034 7OG021035 7OG021036 7OG021037

Part nbr Pack model with single pump 3N~400 V 7OG021043 7OG021044 7OG021045 7OG021046 7OG021047 7OG021048 7OG021049 7OG021050 7OG021051

(1) Values based on inlet/outlet chilled water temperatures from 30/35° and 7°C outside.

(2) Values based on inlet/outlet chilled water temperatures from 12/7° and 35°C outside.

69

Fanconvectors

Aqu@net Cassettes Ducted

Wall units

Air/water chillers

Aqu@logic

Air/water heat pump

CWP

CWP

NEW

Fluid coolers with condensation by water – Reversible heat pumps

7 Cooling Only models from 7 600 to 33 700 W

7 Heat Pump models from 9 000 to 40 100 W

CWP

> Product advantages

Compatible with Water Chilled Airwell terminal units and heating-cooling floor.

Electronic regulation.

Digital display panel.

Indoor installation (equipment rooms, etc.).

Plate type evaporator.

Brazed stainless steel plate type condenser.

Environmentally sealed Scroll compressor.

Accessories

Isolation valve kit VI

CWP 02 CWP 03 CWP 04 CWP 05 CWP 06 CWP 07 CWP 09

CWP HP02 CWP HP03 CWP HP04 CWP HP05 CWP HP06 CWP HP07 CWP HP09

Part nbr 7ACFH0371 7ACFH0371 7ACFH0371 7ACFH0371 7ACFH0371 7ACFH0371 7ACFH0371

Water flow controller CD Part nbr 7ACFH0372

Water lack pressure switch PME Part nbr 7ACFH0373

HP / LP pressure gauges MHPBP Part nbr 7ACFH0374

Water filter kit FE Part nbr 7ACFH0375

Rubber studs PC

Fault return relay RRD

Pressostatic valve VP1

Pressostatic valve VP2

Control transformer TC

Part nbr 7ACTL0186

Part nbr 7ACEL1278

Part nbr 7ACFH0376

Part nbr -

Part nbr -

7ACFH0372

7ACFH0373

7ACFH0374

7ACFH0375

7ACTL0186

7ACEL1278

7ACFH0376

-

7ACEL1277

7ACFH0372

7ACFH0373

7ACFH0374

7ACFH0375

7ACTL0186

7ACEL1278

7ACFH0376

-

7ACEL1277

7ACFH0372

7ACFH0373

7ACFH0374

7ACFH0375

7ACTL0186

7ACEL1278

-

7ACFH0377

7ACEL1277

7ACFH0372

7ACFH0373

7ACFH0374

7ACFH0375

7ACTL0186

7ACEL1278

-

7ACFH0377

7ACEL1277

7ACFH0372

7ACFH0373

7ACFH0374

7ACFH0375

7ACTL0186

7ACEL1278

-

7ACFH0377

7ACEL1277

7ACFH0372

7ACFH0373

7ACFH0374

7ACFH0375

7ACTL0186

7ACEL1278

-

7ACFH0377

7ACEL1277

70

CWP

CWP Series CWP 02 CWP 03 CWP 04 CWP 05 CWP 06 CWP 07 CWP 09

Cooling capacity (1) kW 7.6

Power input kW 1.97

EER 3.9

9.2

2.38

3.9

13.3

3.37

3.9

16.3

3.91

4.2

19.7

5.08

3.9

28

7.16

3.9

33.7

8.8

3.8

Compressor type

Weight

Dimensions (LxPxH)

Scroll kg 115 119 125 138 185 197 201 mm 800x600x910 800x600x910 800x600x910 800x600x910 900x700x910 900x700x910 900x700x910

Evaporator

Capacity l 0.7

Input connection

Output connection

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.7

1-1/4

1-1/4

1.7

1-1/4

1-1/4

2.2

1-1/4

1-1/4

2.2

1-1/4

1-1/4

Condenser

Capacity

Input connection

Output connection l 0.7

1-1/4

1-1/4

0.7

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.7

1-1/4

1-1/4

1.7

1-1/4

1-1/4

2.2

1-1/4

1-1/4

Part number Model 1~230 V 7OG091019 -

Part number Model 3N~400 V 7OG091020 7OG091021 7OG091022 7OG091023 7OG091024 7OG091015

CWP HP Series CWP HP02 CWP HP03 CWP HP04 CWP HP05 CWP HP06 CWP HP07 CWP HP09

Cooling capacity (2) kW 6.5

Power input kW 2.58

EER 2.50

7.9

2.97

2.70

11.5

4.33

2.70

14.2

5.06

2.80

17.1

6.51

2.60

24.4

9.21

2.70

29.4

11.2

2.60

Heating capacity (2)

Power input

COP kW 9 kW 2.58

3.50

10.7

2.97

3.60

15.7

4.33

3.60

19

5.06

3.80

23.3

6.51

3.60

33.2

9.21

3.60

40.1

11.2

3.60

Compressor type

Weight

Dimensions (LxPxH)

Scroll kg 127 130 137 151 204 216 222 mm 800x600x910 800x600x910 800x600x910 800x600x910 900x700x910 900x700x910 900x700x910

Evaporator

Capacity l 0.7

Inlet connection

Outlet connectione

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.7

1-1/4

1-1/4

1.7

1-1/4

1-1/4

2.2

1-1/4

1-1/4

2.2

1-1/4

1-1/4

Condenser

Capacity

Inlet connection

Outlet connection l 0.7

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.1

1-1/4

1-1/4

1.7

1-1/4

1-1/4

1.7

1-1/4

1-1/4

2.2

1-1/4

1-1/4

2.2

1-1/4

1-1/4

Part number Model 1~230 V 7OG091001 -

Part number Model 3N~400 V 7OG091002 7OG091003 7OG091004 7OG091017 7OG091018 7OG091016

(1) Values based on chilled water temperatures of 12/7° C and condenser water temperatures of 29/35° C.

(2) Values based on chilled water temperatures of 12/7° C and condenser water temperatures of 40/46° C.

Chilled water outlet temperature

Chilled water temperature difference

Condenser water outlet temperature

Condenser water temperature difference

Condenser water inlet temperature without pressostatic valve

Condenser water inlet temperature with pressostatic valve

Mini

5 °C

4 °C

26 °C

5 °C

20 °C

15 °C

Maxi

15 °C

6 °C

51 °C

7 °C

45 °C

36 °C

71

ACCESSORIES

Ivory dual flare

Linking pipes

Part number

7ACFH0023

7ACFH0026

7ACFH0032

7ACFH0334

7ACFH0024

7ACFH0027

7ACFH0033

7ACFH0335

7ACFH0025

7ACFH0028

7ACFH0034

7ACFH0464

Wall brackets

Part number

7ACTL0016

7ACTL0018

7ACTL0013

Name

Dual Flare link insulated M1 1/4 & 3/8 - 2,5 m

Dual Flare link insulated M1 1/4 & 1/2 - 2,5 m

Dual Flare link insulated M1 3/8 & 5/8 - 2,5 m

Dual Flare link insulated M1 3/8 & 3/4 - 2,5 m

Dual Flare link insulated M1 1/4 & 3/8 - 5 m

Dual Flare link insulated M1 1/4 & 1/2 - 5 m

Dual Flare link insulated M1 3/8 & 5/8 - 5 m

Dual Flare link insulated M1 3/8 & 3/4 - 5 m

Dual Flare link insulated M1 1/4 & 3/8 - 8 m

Dual Flare link insulated M1 1/4 & 1/2 - 8 m

Dual Flare link insulated M1 3/8 & 5/8 - 8 m

Dual Flare link insulated M1 3/8 & 3/4 - 8 m

Name

Wall bracket for models: 7/9/12/14/15

Wall bracket for models: 18/24/30

Wall bracket for models: 36/45

Electrical accessories

Part number

436670

412040

7ACEL1212

7ACEL1249

RC4

R/C-4

RC-5

All models

All models

RCW2 Wall remote control

RCW2 connection kit for FLO

RC5

Name

RCW2

ACE MARKETING SAS - 1 bis, av. du 8 mai 1945 - Saint-Quentin-en-Yvelines

F - 78284 Guyancourt Cedex

Fax: +33 (0) 1 39 44 65 17 - Tel.: +33 (0) 1 39 44 78 00 - e-mail: [email protected]

www.airwell.com

72

ACE MARKETING RCS VERSAILLES B 421 305 996

Specifications subject to change without notice

Pictures non contractual

- Printed in E.U.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement