Network Cordsets - AS

Network Cordsets - AS
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
Part Number Keys
R4
Cordsets
R7
R14
Field Wireables
R18
Accessories
R20
AS-interface® Media
Receptacles
Features
• Cables that meet the requirements of EN 50295 for communication
•
•
•
•
•
www.turck.us
•
1-800-544-7769 •
up to 167 KBAUD
ITC-ER/PLTC-ER rated cable (CSA FT4)
Oil resistant II and sunlight resistant
7/8 and M12 connectors
Up to 9 Amps and 600 Volt rated
IP67/IP69K rated
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R1
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface System Description
AS-interface (commonly referred to as AS-I) is a low-level I/O interface system. It was originally intended to be a simple, low
cost system that would be easy to install and maintain. With that philosophy in mind, the original developers designed AS-I
as a discrete-only two-wire system. It incorporated features like automatic station addressing, and power and data were
carried on a single untwisted pair of wires.
As the demand for AS-I grew, so did the demand for more complex devices. The next major version of AS-I, v2.1, extended
the protocol to include seamless transfer of analog data, transmission of simple diagnostic data and an extended addressing
scheme that effectively doubled the number of stations allowed on the network. The newest version of AS-I, v3.0, has gone
even further, allowing more options for analog data and much more detailed diagnostic information to be communicated.
New versions of AS-I are backward compatible and support slaves from earlier versions. Additionally, AS-I was one of the first
network systems to incorporate a safety protocol, allowing emergency-stop and machine-stop systems to be seamlessly
integrated with the network.
AS-I can be used as a stand alone network or can be connected to a higher level system, such as DeviceNet™ or PROFIBUS
®
-DP, through a gateway. The gateway acts as a slave to the higher system and a master to the AS-I system.
Typical System Configuration
Basic Parts List
AS-I Master
ASI-DPG
A
AS-I Power Supply
ASI-PS
RSC RKC 254-1M
D
D
RKC 254-1M
ASI-IM-4-1000
B
RSC 254-1M
C
JBBS-25-E633
ASI-IOM-44-1000
C
C
RSC WSC 254-1M
D
D
ASI-PM-1
AS-I Analog Slave
ASI-AI-2
Cable 250
A typical AS-I system consists of the following parts:
A = Master
B = AS-I Power Supply
C = AS-I Cable (See N2)
D = AS-I I/O Modules (or Slaves)
AS-I stations require a network master (also called a scanner) to interface the stations to the host controller. In some cases the
scanner and controller are packaged as a single unit; in other cases the scanner acts as a gateway to a higher level network or
to a PLC. TURCK AS-I stations are designed to be fully compatible with AS-I equipment from other manufacturers.
R2
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
TURCK & Bihl+Wiedemann
Bihl+Wiedemann, considered the "AS-I masters”, is the leading supplier of AS-I master and gateway products. Their broad
product range enables users to select from a wide variety of higher level fieldbuses or PC/PLC control solutions. Additionally,
Bihl+Wiedemann provides a wide variety of analog AS-I slaves, PC-board level devices for OEMs and sophisticated AS-I
accessory products. TURCK has partnered with Bihl+Wiedemann to distribute and support their products in North America.
Cordsets
TURCK offers a complete line of molded AS-I cordsets to facilitate network installation, resulting in a faster start-up and fewer
wiring errors. The bus and drop cables are specially designed foil-shielded, high-flex cables with very low inductance and
capacitance to minimize propagation delay time. AS-I cables consist of a single untwisted and unshielded wire pair that
carries both 30 VDC power and the network data. AS-I was originally designed for use with flat cable using an insulation
displacement connection technology, but the use of round cables with sealed connectors has become more common.
TURCK provides both cable options.
Diagnostics
AS-I has limited field diagnostic capability, due to the limited amount of data transferred in each message. Although with
v2.1, a peripheral fault bit can be reported by an AS-I station to indicate a fault with a field device. This allows the user to
easily determine the location of a system fault down to the station level. AS-I v3.0 has even more diagnostic capabilities,
allowing asynchronous “mailbox” messaging to receive more detailed error information.
Bihl+Wiedemann AS-I masters provide comprehensive information about the status of each station on the network by using
register based tables to display each occupied network address.
The original AS-I system allowed only 4 bits of data to be transferred in each message for a fast and efficient data transfer
system. Slaves could be addressed from one to 31, but with the growth of the network more than 31 stations were often
required. Beginning with AS-I v2.1 stations were available with “AB” addressing. This scheme allows the station to be
addressed from 1A to 31A or 1B to 31B, with 62 total slaves with four discrete inputs and three discrete outputs each. The
extended address range (and the three outputs) is achieved by using one output bit as an AB address.
When both A and B addressed slaves are on the same network, they are scanned on alternating cycles (first all the A slaves are
scanned, then all the B slaves). Both AB and single-address slaves can be on the same network. In this case the single-address
(non AB style) slaves are scanned every cycle. It’s important to note that not all v2.1 slaves use this addressing scheme,
although it is often referred to as v2.1 addressing.
Analog Data
Although the original AS-I version only allowed discrete data transfer, v2.1 and higher support seamless analog data transfer.
This is accomplished by sending a portion of the analog data on each of several consecutive network cycles; for example, a
16-bit word of data requires seven network cycles. Further, AS-I v3.0 allows analog data to be transferred in a single cycle by
consuming more than one address for the analog slave.
Communication Rate/Cycle Time
AS-I communicates at a fixed data rate of 167 kbps. The system’s cycle time is very predictable because of the simple
communication scheme and fixed data rate. For example, a network with 31 slaves will have a cycle time of less than 5 ms. A
network with 62 slaves (all A and B addresses used) will have a cycle time of less than 10 ms. If analog slaves are being used,
the cycle time will change to account for the fact that an analog word takes multiple network cycles to transmit.
Maximum Ratings
The AS-I system uses a freeform layout topology. Up to 100 m of cable can be used on a segment before a repeater or tuner
needs to be installed to allow the network to be extended beyond the 100 m limit. No terminating resistors are required.
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R3
AS-interface® Media
Addressing
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
minifast ® Cordset Part Number Key
Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified.
W K M
25x -
*M
7/8-16UN (minifast)
Length in Meters (*)
R = Straight
W = Right Angle
Consult factory for other lengths.
Gender
Protocol
K = Female Connector, Female Threads
S = Male Connector, Male Threads
25 = AS-interface®
Coupling Nut Material
(Blank) = Nylon
M = Nickel Plated Brass
V = Stainless Steel
minifast Receptacle Part Number Key
R K F
V
25x -
*M /NPT
7/8-16UN (minifast)
Connection Thread
Gender
(Blank) = 1/2-14 NPSM Threads
/NPT = 1/2-14 NPT Threads
/14.5 = 1/2-14 NPT Full Length Threads
/14.75 = 3/4-14 NPT Full Length Threads
/M20 = M20 Threads
K = Female Connector, Female Threads
S = Male Connector, Male Threads
Length in Meters (*)
Designator for Receptacle
Consult factory for other lengths.
Mounting Style
Protocol
(Blank) = Front Mount
P = Back Panel Mount
25 = AS-interface®
Material
(Blank) = Anodized Aluminum
K = Nylon
V = Stainless Steel
Connection Type
(Blank) = Leads or PCB Pins
L = Solder Cup
R4
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
eurofast ® Cordset Part Number Key
Part Number Keys are to assist in IDENTIFICATION ONLY. Consult factory for catalog items not identified.
R S C W V
25x -
*M
M12x1 (eurofast)
Length in Meters (*)
R = Straight
W = Right Angle
Consult factory for other lengths.
Gender
Cable Type (x)
K = Female Connector, Female Threads
S = Male Connector, Male Threads
25 = AS-interface®
Coupling Nut Material
Plug Body
(Blank) = Nickel Plated Brass
K = Nylon
U = PVDF
V = Stainless Steel
C = Large Plug Body
G = Robust Large Plug Body
S = Shielded to Coupling Nut
T = Small Plug Body
Keying Options
AS-interface® Media
(Blank) = Standard Key
D = D-coding Key
W = Reverse Key
eurofast Receptacle Part Number Key
F S F V
25x -
*M
M12x1 (eurofast)
Length in Meters (*)
Consult factory for other lengths.
Gender
Cable Type (x)
K = Female Connector, Female Threads
S = Male Connector, Male Threads
25 = AS-interface®
Housing Style
Keying Options
(Blank) = Front Mount
F = Standard
FD = Standard Back Panel Mount
S = Shielded to Receptacle Housing
SDE = Shielded Back Panel Mount, Large Body
(Blank) = Standard Key
D = D-coding Key
W = Reverse Key
Coupling Nut Material
(Blank) = Nickel Plated Brass
V = Stainless Steel
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R5
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
Notes:
R6
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, Cable Specifications
• AS-interface Cable that Meets the
Requirements of EN50295e
Jacket
for Communication up to 167 Kbaud
Blue
Figure A
• Maximum Cable Length per Segment is 100
Brown
Meters
Inner Jacket
Jacket
Blue
Figure B
Brown
Aluminum Armor
Data Pair
Type
254BK
AWM 2517
105°C 600 Volts
254B
AWM 2517
105°C 600 Volts
255A
105°C 300 Volts
256
AWM 21002
105°C 600 Volts
257
AWM 21002
105°C 300 Volts
2544
AWM 2586
105°C 600 Volts
Outer Jacket
Bulk Cable
Number /
Weight/300 M
Figure
PVC Yellow
7.2 mm (.285 in)
RB51029-*M
53 lbs.
A
4.1 Ohms
PVC/Nylon
PVC Blue
7.2 mm (.285 in)
RB50962-*M
53 lbs.
A
2/16 AWG
BU/BN
4.1 Ohms
PVC
Armor PVC Yellow
13.5 mm (.530 in)
RB50966-*M
105 lbs.
armorfast ®
B
NEC AWM
CEC AWM I/II A/B FT1
2/16 AWG
BU/BN
4.5 Ohms
PE
TPE Yellow
6.2 mm (.244 in)
RB51179-*M
36 lbs.
flexlife-10 ®
A
NEC PLTC/ITC
CEC AWM I/II A/B FT1
2/16 AWG
BU/BN
4.1 Ohms
PE
TPE Yellow
7.2 mm (.285 in)
RB51178-*M
53 lbs.
A
NEC ITC PLTC
Exposed Run, Direct
Burial,
CEC [CMG] FT4
4/16 AWG
BN/WH/BU/BK
4.1 Ohms
PVC
PVC Yellow
8.5 mm (.352 in)
RB51875-*M
94 lbs.
C
Approvals
AWG
Color Code
DCR (/1000 feet)
Insulation
Material Color
Nominal O.D.
NEC ITC PLTC
Open Wiring Direct
Burial
CEC [CMG] FT4
2/16 AWG
BU/BN
4.1 Ohms
PVC/Nylon
NEC ITC PLTC
Open Wiring Direct
Burial
CEC [CMG] FT4
2/16 AWG
BU/BN
NEC ITC PLTC
CEC [CMG] HL BCD
AS-interface® Media
Brown
White
Blue
Black
Figure C
* Indicates length in meters.
Standard spool lengths are 30, 75, 100, 150, 200, 225, 300 meters. Consult factory for other lengths.
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R7
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, Cable and Cordset Selection Matrix
minifast ®
Pin (Male)
1
eurofast ®
Pin (Male)
Socket (Female)
2
3
4
7
RSM
WSM
RKM
WKM
RSC
RSM 25x-*M
WSM 25x-*M
RKM 25x-*M
WKM 25x-*M
RSC 25x-*M
RSM RSM 25x-*M
RSM WSM 25x-*M
RSM RKM 25x-*M
RSM WKM 25x-*M
RSM RSC 25x-*M
WSM WSM 25x-*M
WSM RKM 25x-*M
WSM WKM 25x-*M
WSM RSC 25x-*M
RKM RKM 25x-*M
RKM WKM 25x-*M
RKM RSC 25x-*M
WKM WKM 25x-*M
WKM RSC 25x-*M
Bare
RSM
2
minifast
Pin (Male)
1
Socket (Female)
WSM
3
RKM
4
eurofast
Pin (Male)
WKM
7
RSC RSC 25x-*M
RSC
8
Socket (Female)
WSC
9
RKC
10
WKC
See pages R10 - R11 for dimensional drawings.
* Indicates length in meters.
x Indicates cable type.
Standard cable lengths are 1, 2, 4, 6, 8, 10, 15, and in +5 meter increments from there. Consult factory for other lengths.
For stainless steel coupling nuts change part number RSM… to RSV, WSM… to WSV. For eurofast armorfast ® change part number RSC… to RSA.
Pinouts
minifast
Male
R8
B2007
Female
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. N/C
www.turck.us
•
1-800-544-7769 •
eurofast
Male
Fax: (763) 553-0708 •
Female
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, Cable and Cordset Selection Matrix
Pin (Male)
8
9
minifast ® Bulkhead
Pin (Male)
Socket (Female)
10
5
eurofast Bulkhead
Pin (Male)
Socket (Female)
11
6
12
WSC
RKC
WKC
RSFP
RKFP
FSFD
FKFD
WSC 25x-*M
RKC 25x-*M
WKC 25x-*M
RSFP 25x-*M
RKFP 25x-*M
FSFD 25x-*M
FKFD 25x-*M
RSM WSC 25x-*M
RSM RKC 25x-*M
RSM WKC 25x-*M
RSM RSFP 25x-*M
RSM RKFP 25x-*M
RSM FSFD 25x-*M
RSM FKFD 25x-*M
WSM WSC 25x-*M
WSM RKC 25x-*M
WSM WKC 25x-*M
WSM RSFP 25x-*M
WSM RKFP 25x-*M
WSM FSFD 25x-*M
WSM FKFD 25x-*M
RKM WSC 25x-*M
RKM RKC 25x-*M
RKM WKC 25x-*M
RKM RSFP 25x-*M
RKM RKFP 25x-*M
RKM FSFD 25x-*M
RKM FKFD 25x-*M
WKM WSC 25x-*M
WKM RKC 25x-*M
WKM WKC 25x-*M
WKM RSFP 25x-*M
WKM RKFP 25x-*M
WKM FSFD 25x-*M
WKM FKFD 25x-*M
RSC WSC 25x-*M
RSC RKC 25x-*M
RSC WKC 25x-*M
RSC RSFP 25x-*M
RSC RKFP 25x-*M
RSC FSFD 25x-*M
RSC FKFD 25x-*M
WSC WSC 25x-*M
WSC RKC 25x-*M
WSC WKC 25x-*M
WSC RSFP 25x-*M
WSC RKFP 25x-*M
WSC FSFD 25x-*M
WSC FKFD 25x-*M
RKC RKC 25x-*M
RKC WKC 25x-*M
RKC RSFP 25x-*M
RKC RKFP 25x-*M
RKC FSFD 25x-*M
RKC FKFD 25x-*M
WKC WKC 25x-*M
WKC RSFP 25x-*M
WKC RKFP 25x-*M
WKC FSFD 25x-*M
WKC FKFD 25x-*M
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
AS-interface® Media
eurofast ®
Socket (Female)
R9
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, minifast ® Cordset and Receptacle Connector Dimensions
Specifications
Overmold:
Coupling Nut:
Contact Carrier:
Contacts:
Protection:
Rated Voltage:
Rated Current:
Ambient Temperature:
TPU
Nickel Plated CuZn or Stainless Steel
TPU (Polyurethane)
Gold Plated CuZn
NEMA 1, 3, 4, 6P and IEC IP 67
300 V
9A
-40° to +105°C (-40° to +221°F)
1
RSM ..
2
Pages R8
WSM ..
4
3
RKM ..
WKM ..
Pages R8
5
RSFP ..
R10
B2007
Pages R8
Pages R8
6
Pages R9
www.turck.us
RKFP ..
•
1-800-544-7769 •
Pages R9
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, eurofast ® Cordset Connector Dimensions / Configuration
Specifications
Overmold:
Coupling Nut:
Contact Carrier:
Contacts:
Protection:
Rated Voltage:
Rated Current:
Ambient Temperature:
TPU
Nickel Plated CuZn or Stainless Steel
TPU or POM (Nylon)
Gold Plated CuZn
NEMA 1, 3, 4, 6P and IEC IP 68
250 V
4A
-40°C to +105°C (-40° to +221°F)
8
7
RSC ..
Pages R8 - R9
WSC ..
10
AS-interface® Media
9
Pages R8 - R9
RKC ..
Pages R8 - R9
WKC ..
11
FSFD ..
www.turck.us
12
Pages R9
•
1-800-544-7769 •
Pages R8 - R9
Fax: (763) 553-0708 •
FKFD ..
Pages R9
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R11
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, Tees
• Creates a Drop or Branch from the Main Bus
•
Line
Available in minifast ® or eurofast ® Bus or Drop
Lines
Housing
Part Number
TPU (Polyurethane), stainless steel, 250 V, 4
A (eurofast), 9 A (minifast), -40° to +80°C,
minifast drop connector
RSV FKV RKV 25
TPU (Polyurethane), stainless steel, 250 V, 4
A (eurofast), 9 A (minifast), -40° to +80°C,
eurofast drop connector
RSCV 2RKCV 25
TPU (Polyurethane), stainless steel, 250 V, 4
A (eurofast), -30° to +90°C, eurofast female
drop connector
RKC 2RSC 25
TPU (Polyurethane), stainless steel, 250 V, 4
A (eurofast), -30° to +90°C, eurofast male
drop connector, nickel plated brass
RSCV WKCV 25
TPU (Polyurethane), stainless steel, 250 V, 4
A (eurofast), -40° to +105°C, eurofast male
elbow
RSC RKC 25
TPU (Polyurethane), stainless steel, 250 V, 4
A (eurofast), -40° to +105°C, eurofast male
Pinouts
R12
B2007
Female
Wiring Diagrams
RSV-2RKV 25
minifast
Male
Application
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. N/C
www.turck.us
•
1-800-544-7769 •
eurofast
Male
Fax: (763) 553-0708 •
Female
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, Gender Changers and Elbow Connectors
• Allows Quick and Easy Change from Male to
Female minifast ® Connectors
Part Number
Specs
Application
minifast Male Gender
Changer
RSM RSM 25
RKM RKM 25
Wiring Diagrams
•
TPU (Polyurethane)
250 V, 9 A
-40° to +80°C
Female cordset to
male receptacle
minifast Female Gender
Changer
•
Male cordset to
female receptacle
AS-interface® Media
Housing
minifast Elbow
WSM RKM 25
www.turck.us
•
1-800-544-7769 •
•
Right angle male to
female connector
minifast
Pinouts
minifast
Male
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. N/C
Female
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R13
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, eurofast ® Flat Cable Adapter
• Allows the Mixing of Standard AS-I Flat Cable with eurofast
Round Cable in Same System
• May be Needed when Going from a Dry to a Wet
Environment or an Area Where Better Sealing and Rugged
Connectors are Required
Housing Style
Part Number
Specs
Pinout
ASI-PM-1 BW1239
Female
TPU (Polyurethane)
250 V, 4 A
-40° to +75°C
ASI-PM 41
Data Pair
Type
AWG
Color Code
DCR (/1000 feet)
Insulation
Material Color
Nominal O.D.
2/16 AWG
BU/BN
6.5 Ohms
TPE-S
TPE Yellow
Flat
RB21603-*M
40 lbs.
2/16 AWG
BU/BN
6.5 Ohms
TPE-S
TPE Black
Flat
RB21605-*M
40 lbs.
NEC ITC PLTC
CEC [CMG]
2/18 AWG
BU/BN
6.5 Ohms
PVC
PVC Light Grey
Flat
RB50782-*M
42 lbs.
NEC PLTC
CEC AWM I/II A/B FT4
2/16 AWG
BU/BN
4.1 Ohms
PVC
TPE Grey
Flat
RB51240-*M
42 lbs.
NEC PLTC
CEC AWM I/II A/B FT4
2/16 AWG
BU/BN
4.1 Ohms
PVC
TPE Black
Flat
RB51241-*M
42 lbs.
NEC PLTC
CEC AWM I/II A/B FT4
2/16 AWG
BU/BN
4.1 Ohms
PVC
TPE Yellow
Flat
RB51242-*M
42 lbs.
250
105°C 300 Volts
251
105°C 300 Volts
253
75°C 300 Volts
253G
75°C 300 Volts
253BK
75°C 300 Volts
253Y
75°C 300 Volts
Outer Jacket
Bulk Cable
Part Number /
Weight/300 M
Approvals
* Indicates length in meters.
Standard cable lengths are 1, 2, 4, 5, 6, 8, 10, 15, and in +5 meter increments from there. Consult factory for other lengths.
R14
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, minifast ® Male Receptacles
• Provides Quick Connection to Field Devices or
•
•
Enclosures
Available for 1/2-14NPT, 1/2-14NPSM,
3/4-14NPT and M20 Threads
(7/8-16UN) minifast Connection
Housing
Female Part Number
Male Part Number
Application
Pinouts
RKF 25.../14.5
RSF 25.../14.5
RKF 25-*M/14.5
RSF 25-*M/14.5
Nickel plated CuZn
or stainless steel
300 V, 9 A, -40° to
+105°C, 1/2-14NPT
full length threads
Female
RKF 25.../14.75
RKF 25-*M/14.75
RSF 25-*M/14.75
AS-interface® Media
RSF 25.../14.75
Nickel plated CuZn
or stainless steel
300 V, 9 A, -40° to 1. BN
+105°C, 3/4-14NPT 2. N/C
full length threads 3. BU
4. N/C
Male
RKF 25.../M20
RKF 25-*M/M20
RSF 25-*M/M20
RSF 25.../M20
Nickel plated CuZn
or stainless steel
300 V, 9 A, -40° to
+105°C, M20x1.5
threads
Standard cable length is 0.5 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass. "RKF .."; "RKFV .." indicates 316 stainless steel housing.
For locknuts to be included, add "W/LN" to the end of the part number.
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R15
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, minifast ® Male Receptacles
• Provides Quick Connection to Field Devices or
•
•
Enclosures
Available for 1/2-14NPT, 1/2-14NPSM,
3/4-14NPT and M20 Threads
(7/8-16UN) minifast Connection
Housing
Female Part Number
Male Part Number
Application
Pinouts
RKF ..
RKF 25-*M
RSF 25-*M
Nickel plated CuZn
or stainless steel
300 V, 9 A
-40° to +105°C,
1/2-14NPSM
threads
RSF 25-*M/NPT
Nickel plated CuZn
or stainless steel
300 V, 9 A, -40° to
+105°C, 1/2-14NPT
modified length
threads
RSF ..
Female
RKF ../NPT
RKF 25-*M/NPT
RSF../NPT
Male
Standard cable length is 0.5 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass. "RKF .."; "RKFV .." indicates 316 stainless steel housing.
For locknuts to be included, add "W/LN" to the end of the part number.
R16
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, eurofast ® Male Receptacles
• Mounted for Quick Connection to Enclosures
• (M12x1) eurofast Connectors
Housing
Female Part Number
Male Part Number
Application
Pinout
FK 25...14.5
FK 25-*M/14.5
FS 25-*M/14.5
FS 25...14.5
Nickel plated CuZn or
stainless steel, 250 V, 4
A, -40° to +105°C,
1/2-14NPT full length
threads
Female
FK 25...14.75
FS 25-*M/14.75
FS 25...14.75
1.
2.
3.
4.
BN
N/C
BU
N/C
AS-interface® Media
FK 25-*M/14.75
Nickel plated CuZn or
stainless steel, 250 V, 4
A, -40° to +105°C,
3/4-14NPT full length
threads
Male
FK 25.../M20
FK 25-*M/M20
FS 25-*M/M20
FS 25.../M20
Nickel plated CuZn or
stainless steel, 250 V, 4
A, -40° to +105°C,
M20x1.5 threads
Standard cable length is 0.5 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass. "RKF .."; "RKFV .." indicates 316 stainless steel housing.
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R17
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, eurofast ® Male Receptacles
• Mounted for Quick Connection to Enclosures
• (M12x1) eurofast Connectors
Housing
Female Part Number
Male Part Number
Application
Pinout
FK 25…
Female
FK 25-*M
FS 25-*M
FS 25…
Nickel plated CuZn or
stainless steel, 250 V, 4
A, -40° to +105°C, PG 9
threads
FK 25.../NPT
FK 25-*M/NPT
FS 25-*M/NPT
FS 25.../NPT
Nickel plated CuZn or
stainless steel, 250 V, 4
A, -40° to +105°C,
1/2-14NPT modified
length threads
Male
Standard cable length is 0.5 meters. Consult factory for other lengths.
Standard housing material is nickel plated brass. "RKF .."; "RKFV .." indicates 316 stainless steel housing.
R18
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, minifast ® Field Wireable Connectors with Labels
• Allows for Quick Connection when
Pre-Molded Cables not Available
• Available for Male and Female Connectors
• Color Coded Wire Connection for AS-interface
Housing Style
Female Part Number
Male Part Number
Features
Pinouts
BK 41..
BS 41..
BK 4140-0/9/ASI
BS 4140-0/9/ASI
Glass filled nylon, PG 9 cable gland,
accepts 6-8 mm cable diameter, screw
terminals, 90°C, 250 V, 9 A, mates with
standard, 4-pin cordsets and
receptacles
BSV 4140-0/9/ASI
Glass filled nylon, PG 9 cable gland,
accepts 6-8 mm cable diameter, screw
terminals, 90°C, 250 V, 9 A, mates with
standard, 4-pin cordsets and
receptacles, stainless steel housing
Male
BKV 41..
BKV 4140-0/9/ASI
AS-interface® Media
BSV 41..
Female
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R19
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, eurofast ® Field Wireable Connectors with Labels
• Allows for Quick Connection when
Pre-Molded Cables are not Available
• Available for Male and Female Connectors
• Color Coded Wire Connection for AS-interface
Housing Style
Female Part Number
Male Part Number
Features
Pinouts
B 81..
Female
BS 8141-0/PG9/ASI
PBT, black, PG 9 cable gland, accepts
6-8 mm cable diameter, screw
terminals, 85°C, 250 V, 4 A, mates with
standard, 4-pin cordsets and
receptacles
BS 8241-0/PG9/ASI
PBT, black, PG 9 cable gland, accepts
6-8 mm cable diameter, screw
terminals, 85°C, 250 V, 4 A, mates with
standard, 4-pin cordsets and
receptacles
BS 81..
B 8141-0/PG9/ASI
B 82..
BS 82..
B 8241-0/PG9/ASI
R20
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •
Male
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
AS-interface®, Gender Changer
• Allows Quick and Easy Change from Male to
Female and (7/8-16UN) minifast ® to (M12x1)
eurofast ® Connectors
Housing Style
Part Number
Wiring Diagram
Nickel plated CuZn or stainless steel, 250 V, 4
A, -40°C to +75°C, female eurofast, male
minifast, 4-pin
AS-interface® Media
RSM 25-FK 4.5
Features
Pinouts
www.turck.us
•
1-800-544-7769 •
minifast
eurofast
Male
Female
Fax: (763) 553-0708 •
TURCK Inc. Minneapolis, MN 55441
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
B2007
R21
Return to Main Selection Guide
AS-interface® Physical Media Connectivity
Notes:
R22
B2007
www.turck.us
•
1-800-544-7769 •
Fax: (763) 553-0708 •