B and BI Series Float & Thermostatic Steam Trap Cast Iron for Horizontal Installation, With Thermostatic Air Vent Steam Trapping and Steam Tracing Equipment For Pressures From Vacuum to 30 psig (2 bar)...Capacities to 8,900 lb/hr (4,037 kg/hr) C N K H C N H Alternate Inlet M B B D D Drain Plug Model B Traps Model BI Traps Description Options Armstrong B and BI Series F&T traps combine high standards of performance and long life with economy for heating service where continuous drainage with high air-venting capacity is required. Integral vacuum breaker. Add suffix VB to model number. CAUTION: Do not use a conventional vacuum breaker open to the atmosphere in any system that incorporates a mechanical return system that carries pressure less than atmospheric pressure. This includes all return systems designated as vacuum returns, variable vacuum returns or subatmospheric returns. If a vacuum breaker must be installed in such a system, it should be of the type that is loaded to open only when the vacuum reaches a calibrated level well in excess of the design characteristics of the system. Because of the wide use of vacuum returns in systems of this type, the thermostatic air vent element is charged to give it the capability of compensated response to the pressure-temperature curve of steam at any pressure from less than 20'' (500 mm) Hg vacuum to 30 psig (2 bar) gauge. B and BI Series F&T traps will vent air at slightly below steam temperature throughout this entire range of operation. Specification All B Series traps, except the 1/2'' (15 mm) and 3/4'' (20 mm), have inlet connections on both sides of the body to provide flexibility in piping. The BI Series F&T traps in sizes 1/2'', 3/4'' and 1'' feature the convenience of in-line connections with the same internals as the B Series. Float and thermostatic steam trap, type ... in cast iron, with thermostatic air vent. For a fully detailed certified drawing, refer to CD #1167. Maximum Operating Conditions Maximum allowable pressure (vessel design): Model B2-B3: 125 psig @ 353°F (8.5 bar @ 178°C) Model B4-B8: 175 psig @ 377°F (12 bar @ 191°C) Maximum operating pressure: 15B, BI: 15 psig (1 bar) saturated steam 30B, BI: 30 psig (2 bar) saturated steam How to Order Pressure Model Connection Size Option 15 B 2 VB NOTE: Cast iron traps should not be used in systems where excessive hydraulic or thermal shock are present. Connections B = Standard Connection Screwed NPT and BSPT 15 30 Materials Body and cap: Internals: Valve: Seat: Thermostatic air vent: ASTM A48 Class 30 All stainless steel—304 Stainless steel—303 or 440 Stainless steel—303 (ASTM A582) Stainless steel—440F in 1-1/2'' and 2'' Stainless steel and bronze with phosphor bronze bellows, caged in stainless steel B and BI Series Traps Trap Series Pipe Connections *2=1/2" *3=3/4" 4=1" 5=1-1/4" 6=1-1/2" 8=2" in mm in mm VB = Vacuum Breaker 2=1/2" 3=3/4" 4=1" BI = In-line Connection *No alternate inlet available. B Model in mm in mm in mm in BI Model mm 1/2, 3/4 15, 20 1 25 1-1/4 32 1-1/2 40 2 50 “B” (Height) 4-7/8 124 5-1/2 140 5-1/2 140 7-7/16 189 9-5/8 244 5-5/8 143 “C” (Face to Face) 3-7/8 98 4-7/8 124 4-5/8 117 5-3/4 146 7-5/8 194 5 127 “D” (Bottom to CL) 7/8 22.2 1 25.4 1-7/32 31.0 1-7/16 36.5 1-11/16 42.9 2-11/16 68 5-3/8 137 6 152 7-3/4 197 8-7/16 214 11-5/8 295 6-5/8 168 1/8 3.2 3/8 9.5 — — — — — — — — “M” (CL to CL) 2-3/4 69.8 3 76.2 3 76.2 4-3/16 106 6 152 — — “N” (Top to CL) 2-9/16 65.1 3 76.2 3-3/8 85.7 3-3/4 95.2 5 127 3-9/32 83 “H” (Width) “K” (Connection Offset) Weight lb (kg) 6 (2.7) 8-1/2 (3.9) 11 (5.0) 19 (8.6) 40 (18.1) 1/2, 3/4, 1 15, 20, 25 9-3/4 (4.4) NOTE: Cast iron traps should not be used in systems where excessive hydraulic or thermal shock are present. 120 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information. North America • Latin America • India • Europe / Middle East / Africa • China • Pacific Rim armstronginternational.com B and BI Series Float & Thermostatic Steam Trap Cast Iron for Horizontal Installation, With Thermostatic Air Vent For Pressures From Vacuum to 30 psig (2 bar)...Capacities to 8,900 lb/hr (4,037 kg/hr) Steam Trapping and Steam Tracing Equipment Model B & BI Series Capacity—15 psi Model B & BI Series Capacity—30 psi Options Vacuum Breakers 3/8'' (10 mm) and 1/2'' (15 mm) NPT Many times, condensate will be retained ahead of steam traps because of the presence of a vacuum. To break a vacuum, air must be introduced into the system by means of a vacuum breaker. For maximum protection against freezing and water hammer in condensing equipment under modulated control, vacuum breakers are recommended. Armstrong B and BI Series F&T traps are available with integral vacuum breakers. Maximum pressure is 150 psig (10 bar). D B Vacuum Breakers Size “B” Pipe Connections in mm in mm 1/2 NPT 15 3/8 NPT 10 3/8 NPT 10 1/4 NPT 6 “C” Height 1-1/4 32 1-3/32 28 “D” Width 7/8 Hex 22 Hex 11/16 Hex 17 Hex C Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information. Next North America • Latin America • India • Europe / Middle East / Africa • China • Pacific Rim armstronginternational.com 121
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement