Bullard CAB50HA Datasheet

Bullard CAB50HA Datasheet
netzerotools.com
Clean air.
From a little
yellow box.
Clean Air Box Series (CAB) Breathing Air Filtration Systems
Compliance
OSHA requires that employers provide their workers with Grade D breathing air.
Bullard Clean Air Boxes provide 3-stage filtration and carbon monoxide (CO) monitoring to help
meet this requirement.
Design
Rugged construction for harsh work environments
• Polycarbonate Pelican® Cases (Portable Units)
• Powder Coated Steel (Wall Mount Units)
Automatic condensate drains extend filter element life
Independent regulators (optional) ensure each worker has the proper air flow
3-Stage Filtration
Three stages of filtration remove oil, water, particulate, oil vapor and odors.
• First Stage Removes 95% of solid contaminants and bulk liquids from the breathing
air, down to five microns, prolonging the life of the second and third stage
elements.
• Second Stage - Removes extremely fine oil mists down to .01 microns. Maximum remaining
filter efficiency is 99.9998%.
• Third Stage Removes unpleasant oil and hydrocarbon vapors and odors from the air.
Maximum remaining oil content is .003 ppm by weight. Filter efficiency is
99.9998%.
Filter change indicators visually alerts the operator to replace element
Replacement filters compatible with other brands of filtration panels
CO Monitoring
Auto calibration takes approximately 90 seconds and requires no tools
High intensity 90 dB alarm remote capable with strobe
Self-contained
• 70+ hours of operation on 8-AA batteries
• 110VAC power cord included
Visual display with Internal LCD and External LEDs
netzerotools.com
netzerotools.com
Bullard CAB100HA Clean Air Box Breathing Filtration System
Bullard CAB50HA5 Clean Air Box Breathing Filtration System
Bullard CAB30IRHA Clean Air Box Breathing Filtration System
Bullard CAB50HA Clean Air Box Breathing Filtration System
Bullard CAB30HA Clean Air Box Breathing Filtration System
netzerotools.com
netzerotools.com
Clean Air Box Series (CAB)
Technical Specifications and Ordering Information
Technical Specifications
Filtration Capacity
15 cfm
(425 lpm) at 110 psi (7.5 bar)
50 cfm
(1415 lpm) at 110 psi (7.5 bar)
(850 lpm) at 110 psi (7.5 bar)
30 cfm
100 cfm
(4248 lpm) at 110 psi (7.5 bar)
Filter Efficiency
First Stage: Filters down to 5 microns. 95% of bulk liquids. Automatic drain.
Filter Change Indicator.
Second Stage:
Filters down to .01 microns. 99.9998% efficient. Automatic drain.
Filter Change Indicator.
Third Stage:
Removes oil vapors, odors and tastes. Maximum remaining oil
content .003 ppm/wt. 99.9998% efficient. Filter Change Indicator.
Filter Housing
Polycarbonate bowls.
Inlet1/2” (13mm) Industrial Interchange (Hansen Compatible) male
plug
Outlets1,2,4,or 8 as specified. 1/4” Hansen quick disconnect standard.
Schrader, Snap Tite, CEJN also available Aluminum block manifold
Max Inlet Pressure 150psi (10.3 bar)
Max Outlet Pressure 125psi (8.6 bar)
125psi (8.6 bar) ASME preset
Relief Valve Pressure Regulator Adjustable locking regulator with 0-160 psi outlet gauge.
Construction Wall Panel Units - steel with powder coating
Ordering Information
Portable Units*
CAB15
CAB30
CAB30IR
CAB50
CAB50IR
CAB100
CAB100IR
Wall Units*
CAB15PM
CAB30PM
CAB30PMIR
CAB50PM
CAB50PMIR
CAB100PM
CAB100PMIR
Replacement Parts
CAB30FEA
CAB30FEB
15 cfm with one outlet
30 cfm with two outlets
Same as above with Independent Regulators
50 cfm with four outlets
Same as above with Independent Regulators
100 cfm with eight outlets
Same as above with Independent Regulators
15 cfm with one outlet
30 cfm with two outlets
Same as above with Independent Regulators
50 cfm with four outlets
Same as above with Independent Regulators
100 cfm with eight outlets
Same as above with Independent Regulators
Stage 1 Element for 15 or 30 cfm
Stage 2 Element for 15 or 30 cfm
Portable Units Polycarbonate Pelican
case
MonitorFlow-thru In-line
continuous operation
VoltagePortable Units: 115-volt AC (10’ cord
included) or 8-AA batteries. Monitor switches automatically to DC
with AC power failure Wall Units: 110/220 VAC, wiring required.
Display
Internal digital LCD display
Accurate +/- 1% of full scale
Operation Lights
External green light - normal AC operation
External red light - high CO
External amber light (steady) - battery power in use
External amber light flashing - low battery with flashing chirp
High intensity 90 dB
Audible Alarm
Response
90% of full scale in 10 seconds
Sensor
Electrochemical (CO specific)
Output Signal
Remote alarm jack with DC output and cover cap
CalibrationAuto calibration (no tools required). Completes in 90 seconds.
Recommended monthly.
Warranty
Two years on sensor and monitor
Replacement Parts
CAB30FEC
CAB30FK
CAB50FEA
CAB50FEB
CAB50FEC
CAB50FK
CAB100FEA
CAB100FEB
CAB100FEC
CAB100FK
CABRS
CABRS2
Accessories
CABCK
RA
CABKS1530**
CABKS50100**
V25HA
Stage 3 Element for 15 or 30 cfm
Element kit, includes Stages 1-3 for 15 or 30 cfm
Stage 1 Element
Stage 2 Element
Stage 3 Element
Element kit, includes Stages 1-3
Stage 1 Element
Stage 2 Element
Stage 3 Element
Element kit, includes Stages 1-3
CO Monitor Sensor Element - Older Units
CO Monitor Sensor Element - Newer Units
Calibration Kit
Remote Alarm
Kickstand FOR CAB15 or CAB30
Kickstand FOR CAB50 or CAB100
1/4” splitter
*Specify outlet fitting when ordering
**Must be ordered with Clean Air Box
WARNING
These units will not remove Carbon Monoxide (CO), Carbon Dioxide (CO2), Nitrogen, or other toxic gases or fumes. These units will not increase the oxygen content of an air supply and
should not be used when air entering the system is oxygen deficient. Air filtration systems must be operated in the upright position to allow the auto drains to properly seat. The standard
Clean Air Box (CAB) filtration units are not explosion proof and should be located in a non-explosive environment.
Bullard products are manufactured to exacting specifications. Any alteration or modification of these products by the user may adversely affect product performance. This information is
in summary form only for easy reference. Refer to labels, instruction sheets and other literature accompanying the product for more complete details regarding product installation, use,
maintenance, warnings, performance capabilities, complete specifications, user instructions and precautions.
netzerotools.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement