Installation and cabling features
Rear Panel
r
fo d
m
T
o
an
AN k.c ual
T
n
R
n
li
ct
PO .rgb ma ns
du
M
o
r
I
w se tio pr
ww te u truc the
s
to le
g
.
er mp n in ctin rce
f
e
o
o
u
e
i
c
R e
t nn so
la
th tal co er
s
in fore pow
be the
to
Connections
1 2 6 7
LAN RJ-45 port
16 DVI input connector
3 8
Power connector
17 DSUB 15 pin VGA input connector
USB control port
18 DVI output connector
Sending card DVI Input connector
19
11
Mini switches
20 Power switch button
13 14
Composite female BNC connectors
21 Power cord connector IEC-3
15
USB Input connector
4 9
5 10
12
DVI output connector
NOTE 1 2 3 4 is not standard module.
Step 1-Mounting
Turn off or disconnect all equipment power sources.
Step 2-Composite input
Used to input composite signal
(PAL, NTSC, SECAM compatible).
Step 3-USB input
Used to play media files from disk with
USB connect or portable Hard Disk.
Step 4-DVI input
Input the video signal from computer,
DVI signal generator and so on.
Step 5-VGA input
Input from computer or VGA source.
Step 6-DVI output
Connect to the monitor or LED control
system which has DVI interface.
Step 7-VGA output
Connect to the monitor,
projector and so on.
Step 8-USB port
NOTE User could use a DVI to DVI+VGA
adaptor to accept DVI and VGA signal,or
use a DVI to VGA adaptor to accept VGA
signal
One side of DVI to
DVI+VGA adaptor is with
DVI-I or DVI-D male
interface, another side is
DVI-I or DVI-D female
interface
One side of DVI to
VGA adaptor is with
DVI-I male
interface,nother side is
VGA female interface
Use USB cable to connect the VSP 112 and computer.
Address:S603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen,Fujian Province, P.R.C
Tel: 00865925771197
Fax:00865925771202
Email: [email protected]
http://www.rgblink.com
VSP 112 Quick Start
Rev 1.1
Page 1 of 2
Step 9-LAN(Ethernet) port
Use twist CAT5 cable to connect to LAN port, user can
control VSP 112 based on default IP address: 192.168.0.100.
User can also change the IP address by RS 232 or USB.
Twist CAT5 should be one end in T568A, and another end
in T568B standard.
Step 10-Power
Keep push and hold on UP or DOWN
Plug in power cord which has IEC connector, VSP 112
support AC power from 85 to 260 VAC,50-60Hz, which
means world wide compatible.
Powering Up
Push power button switcher to ON position. LCD module
on the front panel will show RGBLINK and VSP 112
model information, and go into self verification before it
load the last setting configuration data and send the
processed image to the target display or device. For the
first time running, CV1 input is the default input source.
User can operate with VSP 112 with local front panel and
remote control with the software run on the PC, remote
control by USB .
NOTE button, the value of the size or position will change
faster and faster during setting values.
Step 4-Save
VSP 112 support 3 user setting mode. Push SAVE button and
SVAE1, SVAE2, SAVE3 buttons will light on, push any one
of them to save the setting. After that user can push each of
them to call the setting.
SAVE1 setting is default user setting after VSP 112 power
NOTE on. All the user settings will gone after factory reset.
Factory reset:After wrong operation, users need to do factory to
make all the configurations default value, Push MENU button,
find the recall option, press SEL button to do factory reset.
Local control - Front Panel Operations
Step 1-Output resolution
Push OUT button and use UP or DOWN button to go to the
right resolution for the monitor or display system, and push
SEL button to decide to go to the resolution.
VSP 112 support 8 output formats.
NOTE 800x600x60Hz
1024×768×60Hz
1280×768×60Hz 1280×1024×60Hz
1440×900×60Hz 1400×1050×60Hz
1920×1080×60Hz 1600×1200×60Hz
Output resolution should be the same or bigger than
monitor or display system resolution.
Step 2-Input Switch
Step 3-Scale
Push Scale button and go into scale setting manual. Use UP
or DOWN to go to Horizontal size, Vertical size, Horizontal
position, Vertical position setting page, and push SEL to
decide to set, and use UP or DOWN to change the size or
position value. Push SEL to send and exit from the setting.
Insert Twisted
Pair Wires
RJ-45
Connector
Crossover Cable
Pin
End 1
Wire color
End 2
Wire color
1
2
3
4
5
6
7
8
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
T568A
NOTE For setup
software, please
check with user
manual. And install
correct language
version to work
with right language
user interface.
Step 1-Set up communication
Use the RS 232 port on the computer, baudrate should be 115200.
VSP 112 support 5 input source, CV1, CV2, USB, DVI,
VGA, push each source button, will switch to each source
input, and display on the target monitor or display system.
NOTE When there is not video or graphic input
for the input source, and user switch to the
input, the last frame of the video or graphic of last input
will keep on display.For push to USB input, will always
go to USB input show window.
Pins
Remote control - Software Operation
T568B
CAT5 is
wired as
T568A at
one end and
T568B at
the other(Tx
and Rx
pairs
reversed) is
crossover.
Set COM
Open COM
Close COM
Step 2-Output resolution
Select output resolution from pull down output list.
Step 3-Scale
User can scale the image with mouse drap and drop
operation; User can also scale by input the data into the scale
parameters and set.
Step 4-Save
Push “Save to flash” button and
select one of user mode to save, there
are three user mode in the list.
Save to flash
button, use to save
user mode
NOTE Factory reset: User need to
do factory reset after wrong operations
to reset all the configurations to the
default setting. Click on the control
menu, select factory reset option.
Address:S603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen,Fujian Province, P.R.C
Tel: 00865925771197
Fax:00865925771202
Email: [email protected]
http://www.rgblink.com
VSP 112 Quick Start
Rev 1.1
Page 2 of 2
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement