- No category
advertisement
Technical slides
Basic Controller in the TIA Portal
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
www.siemens.com/s7-1200
SIMATIC Controller
S7-1200
Security Integrated.
+
Technology Integrated
+
+
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 2
Efficient engineering
+
Diagnostics
+
+
Innovative design and easy t to use
+
Design and handling
S7-1200 CPU
Digital inputs
Modular board concept
PROFINET interface (1 or 2 ports)
S7-1200: Modular. Powerful
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 3
Analog inputs
Optional memory extension
Integrated HSCs & PTOs/PWMs
Removable connectors
Digital outputs (DC or relay)
Design and handling
S7-1200 CPU - setup
Current connection
Slot for a memory card below the upper cover flap
Plug-in terminal block
(behind the cover flaps)
Status LEDs for the
PROFINET connection of the CPU)
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 4
Design and handling
Set-up and extension options - maximum
CM/CP CPU SM
1 board
CPU 1211C
CPU 1212C
CPU 1214C / 1215C / 1217C variable extension and set-up options for differing requirements
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 5
Design and handling
Extension module assembly
Installation
1. Remove backplane bus cover
2. Insert SM into standard mounting rails
3. Guide the SM to the adjacent module
4. Lock the standard rail mounting clamp
5. Guide the bracket for the bus towards the adjacent module
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 6
Configuration
1. Loosen the bus connector contact by pushing the bolt to the right
2. Move SM right onto standard mounting rail
3. Unlock standard mounting rail clamp
4. SM out of standard mounting rail
Design and handling
CPU – 17 Versions incl. failsafe
CPU 1212C
…DC/DC/DC
…AC/DC/RLY
CPU 1214C
…DC/DC/DC
…DC/DC/RLY
…AC/DC/RLY
CPU 1215C
…DC/DC/DC
…DC/DC/RLY
…AC/DC/RLY
CPU 1211C
…DC/DC/DC
…DC/DC/RLY
…AC/DC/RLY
variable extension and set-up options for differing requirements
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 7
CPU 1217C DC/DC/DC
Design and handling
CPU dimensions
CPU 1215C
CPU 1214C
CPU 1212C
CPU 1211C
150
90
110 variable extension and set-up options for differing requirements
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 8
CPU 1217C DC/DC/DC
150
Design and handling
Optional CPU functional enhancements using boards
Board type
SB 1221
SB 1222
SB 1223
Characteristics
4 DI, DC 5V, HSC with up to 200 kHz available for use
4 DI, DC 24V, HSC with up to 200 kHz available for use
4 DQ DC 5V, 0.1 A, PWM with up to 200 kHz, PTO with up to 100 kHz available for use
4 DQ DC 24V, 0.1 A, PWM with up to 200 kHz, PTO with up to 100 kHz available for use
2 DI, DC 5V, 2 DQ DC 5V, 0.1 A, HSC with up to 200 kHz, PWM with up to 200 kHz, PTO with up to 100 kHz available for use
2 DI, DC 24V, 2 DQ DC 24V, 0.1 A, HSC with up to 200 kHz, PWM with up to 200 kHz, PTO with up to 100 kHz available for use
SB 1231 AI 1 AI, ±10VDC (12 bit) or 0…20 mA
SB 1231 RTD 1 AI RTD, PT 100 and PT1000
SB 1231 TC 1 AI thermal elements type J or K
SB 1232 AQ 1 AO, ±10VDC (12 bit) or 0…20 mA (11 bit)
CB 1241 RS485 communication board
Seite 9
Design and handling
SIMATIC S7-1200 with FW4.1
SIMATIC S7-1200 CPU
PROFINET Ports
Work memory /
50 KB
Bit performance
Connection resources
Integrated Digital I/O
Integrated Analog I/O
High-Speed Counter
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 10
85 ns
38
6/4
2/-
6
75KB
85 ns
38
8/6
2/-
6
100kB
85 ns
38
14/10
2/-
6
125kB
85 ns
38
14/10
2/-
6
125 kB
85 ns
38
14/10
2/2
6
150 kB
85 ns
38
14/10
2/2
6
150 kB
85 ns
38
14/10
2/2
6
Design and handling
How does the S7-1200 CPU use the SIMATIC memory card?
Program card
• acting as a CPU memory.
• Loss of all project and program data upon removal of a program card from the CPU.
• Replacement and extension of the CPU-internal load memory
Transfer card
• For transfer of project and program data into the CPU-
• Removal following data transfer
CPU works with the data saved in your memory.
• For duplication of project and program data in multiple CPUs load
with an SD card slot
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 11
Design and handling
SIMATIC S7-1200 accessories
Accessory part
PM1207
Battery board
CSM 1277
Compact Switch Module
Digital SIM 1274 input simulator
Analog input simulator
Extension cable
Details
Inputs: 120/230 V AC
Outputs: 24 V DC / 2.5 A for real-time clock long-term buffering
(without CR1025 battery)
4 x RJ45 jacks
10/100 MBit/s
Potentiometer for direct entry of analog value
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 12
SIMATIC S7-1200
Security Integrated - Increased copy protection
• Linkage of individual blocks to the serial number for the memory card or CPU
• Protection from unauthorized copying of program blocks with STEP 7
• Protection from unauthorized duplication of the configuration on the memory card
Protection from unauthorized reproduction of executable programs
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 13
SIMATIC S7-1200
Security Integrated - Dynamic copy protection with mandatory password
Copy protection with different methods for providing a target serial number:
As of
V4.1
•
Static linkage:
direct configuration of a target serial number
(from memory card or CPU) for program blocks
•
Dynamic linkage:
automatic detection of a target serial number with linkage to this target serial number during the download on the CPU or memory card
Advantages:
• Both cases involve linkage of the block to a special
HW serial number for the CPU or the memory card
• A block with dynamic linkage in the TIA Portal project is not tied to a certain serial number but is protected via an additional password for copy protection (from STEP 7 V13 SP1)
Automatic serial number configuration
and simple linkage for machine manufacturers
Simple mass download
with copy protection for authorized person only
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 14
Program block with static linkage
Target serial number:
12345678
Download with check of the serial number by the controller
Program blocks with dynamic linkage
Automatic detection
Download with automatic integration of the serial number by the TIA Portal
S7 Controller
Program blocks with active copy protection
12345678
SIMATIC S7-1200
Security Integrated - Increased manipulation protection
• Improved protection from manipulation of the communication with access to the controller by digital checksums
• Protection from network attacks such as infiltration of fake / recorded network communication (replay attacks)
• Protected transfer for passwords upon authentication
• Detection of manipulated firmware updates through digital signatures
availability
Frei verwendbar / © Siemens AG 2015. Alle Rechte vorbehalten.
Seite 15
SIMATIC HMI portfolio
„Efficient to a new level“
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 16 V1.0
SIMATIC HMI Basic Panels 2 nd
Generation
Basic Excellence – Top Highlights at a Glance
Fi h i f simple applications
+
High-resolution
64.000 colors
+
Innovative graphical user interface
+
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 17
Consistent functionality across all display sizes
+
USB interface for auxiliary Equipment and simple Backup/ Restore
+
V1.0
SIMATIC HMI Basic Panels 2 nd
Generation
Beauty is simplicity – Innovative Functionality at an Attractive Price
Feature / function
• Efficient engineering with
Wi CC V13
(TIA Portal)
• Perfect interplay with new especially S7-1200
• High-resolution display:
Wide-screen, 64.000 graphical user interface
• Easy logging with USB
Benefit
• Reduction of engineering time: ONE engineering framework for all automation applications
• Reduction of engineering through rapid project engineering
• Innovative panel technology for ti l ti
• Innovative presentation of applications
• Reduced commissioning expenditures
• Easy process monitoring
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 18 V1.0
SIMATIC HMI Comfort Panels
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 19 V1.0
SIMATIC HMI Comfort Panels
Consistent functionality of all Comfort Panels
Archives, scripts, Internet Explorer, PDF/Excel/Word viewer,
Media Player, F(x) – functions, system diagnostics viewer, …
All Comfort Panels offer the same high-end functionality over all display sizes.
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 20 V1.0
SIMATIC HMI Comfort Panels
Consistent functionality of all Comfort Panels
Key devices from 4“ up to 15“
Optimal feedback by embossed function keys
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 21 V1.0
SIMATIC HMI Comfort Panels
Integrated functionality of all Comfort Panels
Interfaces available for:
USB host (flash drive, mouse, keyboard,
...
)
Various communication possibilities by standardized interfaces
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 22 V1.0
SIMATIC HMI Comfort Panels
Aluminum front-side casings
Robust hardware by a durable aluminum front-side casings starting with the 7-inch model
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 23 V1.0
SIMATIC HMI Comfort Panels
Widescreen Display
www.siemens.com/simatic-hmi-widescreen
Widescreen displays for detailed display, high ease of use and best readability
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 24 V1.0
SIMATIC Comfort Panels
Dimmable LED backlighting
LED backlight is dimmable … application (e.g.: in shipbuilding)
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 25 V1.0
SIMATIC HMI Comfort Panels
Maximum data security during a power failure
„Data“ slot for archives and other data
Maximum data security for archives in RDB format
SIMATIC HMI Memory Card. *
1
f C f
*
1
To secure the preservation of single, not yet archived data by
100% it is recommended to use an interruptible-free power supply.
Inexpensive preservation of all data without using an additional battery.
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 26 V1.0
SIMATIC HMI Comfort Panels
Innovative service concept
„System“ slot for automatic backup
Automatic backup of all process relevant data
The backup is made at the same time with
No manual actions required.
Fast device exchange and commissioning by
Insert card
confirm message done
Automatic backup and fast device exchange by an innovative servicing concept.
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 27 V1.0
SIMATIC HMI Comfort Panels
Touch device mounting positions application requirements and available space.
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 28 V1.0
SIMATIC HMI Comfort Panels
Printer
Expansion of the already supported standard printers
PDF print (print as a PDF file)
HTML print (print as an HTML file)
PostScript print
(print via any postscript-compatible printer)
A li ti l h ttp://support.automation.siemens.com/WW/view/de/58205602 http://support.automation.siemens.com/WW/view/en/58205602
Printer driver: t t ti i /WW/ i /d /11376409 http://support.automation.siemens.com/WW/view/en/11376409
Printout of process data without printer specific printer drivers or into a file format.
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 29 V1.0
SIMATIC HMI Comfort Panels
Other highlights
Innovative features for commissioning, operating and maintenance
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 30 V1.0
Mobile Panels 2nd Generation
… the next level of mobile HMI devices
Unique emergency button
+
PROFINET / PROFIsafe
+
Performance like a Comfort Panel
+
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 33
Compact connetivity
+
Sturdy and brilliant at once
+
V1.0
Mobile Panels 2nd Generation
… more power, comfort, flexibility and quality!
The second generation of SIMATIC HMI Mobile Panels convinces with its ease-of-use, performance and quality.
The highlights are – a brilliant widescreen display, exceptionally easy engineering and the unique illuminated emergency stop button.
Mobile Panels 2nd Generation - Power and Safety in your hands
Connection box
-advanced
Wall bracket
KTP700(F) Mobile
-standard
-compact
Connection cable
User-friendly
Comfortable in your hands
Bright and brilliant display
Style editor
Flexibel
Non-Safety or Safety version
Diverse connectivity variants
Safe and secure
TÜV certificated to SIL3 / PL e bli it h
Emergency button or stop switch
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 34 V1.0
Mobile Panels 2nd Generation
Operational area for mobile HMI
Mobile Panels offer a direct access and optimal visual contact to the process!
• High flexibility
• Integr. Safety
• Ergonomically
• Sturdy
• warehouse/ Logistics
• Packaging
• Machine building
• Automotive
Operating area:
• Service
• Setup mode
• Troubleshooting
• Secure operating
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 35 V1.0
Mobile Panels 2nd Generation
… mobiles controlling and monitoring still efficient and secure
Feature / Function
• central engineering-tool TIA
Portal (WinCC) with innovative style-editor
• rugged and brilliant at once:
7” und 9” devices
• new connection boxes for direct
• illuminated emergency button
• evaluation per software wiring
Kundennutzen
• g tasks, even with your own individual design
• high quality for every industry
• detailed presentation of complex pictures of process
• Economically priced connection possibilities for small machines with minor spot offers
• flexible in use and evaluation of
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 36 V1.0
Extreme Operating
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 37 V1.0
New Challenges for HMI Panels
Unrestricted / © Siemens AG 2015. All Rights Reserved.
Page 38 V1.0
advertisement